Loading...
HomeMy WebLinkAboutFile Documents.1001 E Cooper Ave.0039.2019 (16).ARBKResidential Design Standards Exemption Form Exemption Applies Notes Remodel of a structure where the alterations proposed change the exterior of the building, but are not addressed by any of the Residential Design Standards Residential unit within a mixed-use building Designated historic resource listed on the Aspen Inventory of Historic Landmark Sites and Structures Has already received a board design approval Disclaimer: This exemption is only valid for the attached scope of work. If the project scope ex- pands to include work subject to Residential Design Standards, the applicant shall be required to apply for an Administrative Compliance Review. Address: Parcel ID: Zone District/PD: Representative: Email: Phone: Scope of Work: Reviewed by: (Project plans/elevations attached) 02/25/2019 Residential Design Standards Administrative Review Section 26.410.020.B. of the Land Use Code requires an Administrative Review for compliance with the Residential Design Standards (RDS) for all residential projects, unless otherwise exempted pursuant to Section 26.410.010.C. All residential projects affecting the exterior of the building shall submit for RDS Administrative Review prior to building permit submittal. If exterior work is proposed, and the scope of work meets one of the exemptions listed above, staff shall provide a signed exemption form to be included in the building permit application. Review Process: The Community Development Department staff shall review an application for applicability and compliance with Chapter 26.410, Residential Design Standards. If the application complies with all applicable standards as written, a signed Checklist and stamped plan set shall be provided to the applicant to be included with building permit submission. If the application does not comply with one or more applicable standards, an unsigned Checklist and redlined plan set shall be emailed to the applicant including comments from staff on which standard(s) the application does not comply with and a description of why the standard(s) is not compliant. The applicant shall be provided the opportunity to revise and resubmit the design in response to the comments. Staff will keep an application open for 30 days from the date an unsigned Checklist is emailed to the applicant. If after such time no revisions are submitted, the application will expire. Application for RDS Administrative Review: An application for RDS Administrative Review that DOES NOT require Alternative Compliance (see Page 2) shall be submitted to the Community Development front desk on a USB drive or emailed to planneroftheday@gmail.com. Applicants will be notified of received application by email and if additional documents are required. Certain application requirements may be waived by staff depending on the scope of work. An application for RDS Administrative Review shall include the following documents in digital format: •Site improvement survey certified by a registered land surveyor (no older than one year from submittal date) •Proposed Site plan (scaled 24”x36”) •Proposed Floor plans (scaled 24”x36”) •Proposed Elevations (scaled 24”x36”) •Existing Elevations if a remodel (scaled 24”x36”) •Complete scope of work noting all exterior areas affected by the proposed project •Complete RDS applicant checklist (attached) addressing how each standard is met with sheet references for each standard Page 1 of 2 02/25/2019 Alternative Compliance or Variation: Pursuant to 26.410.020.C, projects that do not meet the criteria for Administrative Review or Alternative Compliance (as determined by staff) may be reviewed by the Planning & Zoning Commission, or HPC if appropriate, at the applicant’s request. An applicant may choose to apply directly for a Variation from the Planning & Zoning Commission or Historic Preservation Commission, pursuant to Chapter 26.410.020.C. A pre-application summary will be required for an Alternative Compliance or Variation request. Application for Alternative Compliance or Variation: An application for Alternative Compliance or a Variation will require a pre-application summary provided by Community Development staff, and shall be submitted as a Land Use Application. Required application submittal items shall be outlined in the pre-application summary. Page 2 of 2 Residential Design Standards Administrative Review 02/25/2019 NEW TO MATCH EXISITING NEW TO MATCH EXISITING UNIT 2 CLIENT IS WANTING BETTER U-FACTORS - NO CHANGE TO LOOK OF BUILDING 2019-02-04 Residential Design Stds 02/25/2019 Residential Design Standards Administrative Compliance Review Applicant Checklist - Multi-family Development Standard Complies Alternative Compliance N/A Sheet #(s)/Notes B.1.Building Orientation (Flexible) B.2.Garage Access (Non-flexible) B.3.Garage Placement (Non-flexible) B.4.Entry Connection (Non-flexible) B.5Principle Window (Flexible) Instructions: Please fill out the checklist below, marking whether the proposed design complies with the applicable standard as written or is requesting Alternative Compliance (only permitted for Flexible standards). Also include the sheet #(s) demonstrating the applicable standard. If a standard does not apply, please mark N/A and include in the Notes section why it does not apply. If Alternative Compliance is requested for a Flexible standard, include in the Notes section how the proposed design meets the intent of the standard(s). Additional sheets/graphics may be attached. Disclaimer: This application is only valid for the attached design. If any element of the design subject to Residential Design Standards changes prior to or during building permit review, the applicant shall be required to apply for a new Administrative Compliance Review. Address: Parcel ID: Zone District/PD: Representative: Email: Phone: Page 1 of 1 02/25/2019 Scope of Work - 1001 E. Cooper Avenue, Unit 2 The Villager Townhomes was built in 1965 with eight residential units. All units were designed with an interior courtyard with an unheated walkway from the building facade accessing the unit and the courtyard. Over the years the units have been remodeled individually and many have enclosed all or part of the interior courtyards. The proposed scope of work is to reduce the size of the courtyard to gain additional interior square footage. This enclosure is not visible from the street and is allowed from a floor area perspective for the zone district. 02/25/2019 UP UP 1 1 3 3 A A C C 100 BEDROOM 102 CLOSET 103 STORAGE 107 MECHANICAL 105 CLOSET 108 CLOSET 109 BATH 110 BEDROOM 106 HALL 101 STAIR 104 EXTERIOR HALL 20 ' - 1 " 38' - 8" OPEN TO ABOVE MECHANICAL CHASE B B 2 2 4' - 4 1 / 4 " 15 ' - 8 3 / 4 " 9' - 2 5 / 8 " 10' - 6 1/2"6' - 7"8' - 5"11' - 6" 10 ' - 2 1 / 2 " 7' - 4 " 2' - 1 0 7 / 1 6 " 5' - 3 " 3' - 1 0 3 / 4 " 3' - 0 " CEILING ABOVE 1 1 3 3 A A C C 20 ' - 1 " 38' - 8" B B 2 2 FLOOR PLAN GENERAL NOTES - DEMOLITION 1.DEMOLITION SHALL BE LIMITED SOLELY TO ITEMS SPECIFICALLY SHOWN IN THE DRAWINGS. THE INTENT IS TO SHOW THE GENERAL SCOPE OF DEMOLITION REQUIRED TO PREPARE FOR THE RENOVATION. SEE ALL ARCHITECTURAL AND CONSULTANT DRAWINGS (INCLUDING, BUT NOT LIMITED TO: FLOOR PLANS, INTERIOR ELEVATIONS, DETAILS, AND SCHEDULES) FOR FULL EXTENT OF WORK. 2.ALL STRUCTURE, EXISTING TO REMAIN, SHALL BE PROPERLY SHORED AND/OR SUPPORTED IN ACCORDANCE WITH THE CONTRACTED STRUCTURAL ENGINEER’S “WAYS AND MEANS”GUIDELINES. CONTRACTORS TO ASSUME LIABILITY FOR SUCH MOVEMENT, SETTLEMENT, DAMAGE, OR INJURY RESULTING FROM DEMOLITION WORK. 3.COMPLY WITH ALL APPLICABLE LOCAL, STATE, AND FEDERAL CODES AS WELL AS REGULATIONS PERTAINING TO THE SAFETY OF ALL PERSONS, PROPERTY, AND ENVIRONMENTAL PROTECTION. 4.CEASE OPERATIONS IMMEDIATELY IF SAFETY OF STRUCTURE APPEARS TO BE ENDANGERED. DO NOT RESUME OPERATIONS UNTIL SAFE CONDITIONS ARE RESTORED. 5.VERIFY STRUCTURAL VIABILITY OF DEMOLITION IN FIELD. COORDINATE WITH ARCHITECT AND STRUCTURAL ENGINEER UPON REMOVAL OF FINISHES TO ASSESS CONDITIONS. 6.REMOVE FROM SITE AND LEGALLY DISPOSE OF REFUSE, DEBRIS, RUBBISH, AND OTHER MATERIALS, RECYCLING AS REQUIRED, RESULTING FROM DEMOLITION OPERATIONS DAILY. SITE TO BE LEFT BROOM CLEAN AND READY RO RECEIVE NEW FINISHES DAILY. 7.REMOVE ALL INTERIOR GYPSUM BOARD FROM WALLS AND CEILINGS AS REQUIRED FOR ABATEMENT AND PROPOSED WORK. 8.PATCH AND REPAIR DRYWALL AS NECESSARY. PATCH WALL AT ALL INTERSECTIONS OF DEMOLISHED WALLS. 9.EXISTING FIRE RATED ASSEMBLIES TO REMAIN INTACT OR REPAIRED TO MEET FIRE RATING. 10.NOTIFY OWNERS AND NEIGHBORS OF ANY UTILITY SHUT OFF OR INTERRUPTION OF SERVICE. 11.ALL SMOKE DETECTORS PER CITY OF ASPEN TO BE REPLACED WITH COMBINATION SMOKE/CARBON MONOXIDE DETECTORS. 12.SALVAGE ALL EXISTING EQUIPMENT AND FURNITURE. VERIFY W/ OWNER PRIOR TO REMOVAL. COORDINATE FOR STORAGE, RECYCLING OR LANDFILL. 13.EXISTING ELECTRICAL, LIGHTING, BRANCH WIRING/CIRCUITING, JUNCTION BOXES, ETC TO BE EVALUATED ON SITE FOR RE-USE OR REMOVAL AND REPLACEMENT. SEE ELECTRICAL DOCUMENTS. 14.EXISTING MECHANICAL/HVAC SYSTEM TO BE EVALUATED PER PARTIAL REUSE OR REMOVAL AND REPLACEMENT. SEE MECHANICAL DOCUMENTS. 15.EXISTING PLUMBING TO BE EVALUATED AND COORDINATED FOR PARTIAL RE- USE OR REMOVAL AND REPLACEMENT. SEE PLUMBING DOCUMENTS. FLOOR PLAN PHASING LEGEND EXISTING TO REMAIN EXISTING PARTITION, MILLWORK, FIXTURE, OR WALL TO BE REMOVED rowland+broughton architecture / urban design / interior design 234 e. hopkins ave. aspen, co 81611 970.544.9006 o 970.544.3473 f 1830 blake st. ste. 200 denver, co 80202 303.308.1373 o 303.308.1375 f Consultants: Issuances and Revisions: COPYRIGHT 2019 ROWLAND + BROUGHTON ARCHITECTURE AND URBAN DESIGN THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS THE PROPERTY OF ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN. NO PART OF THIS INFORMATION MAY BE USED WITHOUT THE PRIOR WRITTEN PERMISSION OF ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN. ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN SHALL RETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING COPYRIGHT THERETO. SCALE: SHEET TITLE: PROJECT NO: Fi l e P a t h : Pl o t D a t e :NOT FOR CONSTRUCTIONC: \ U s e r s \ d t r a n \ D o c u m e n t s \ 2 1 8 3 3 . 0 0 _ V I L L A G E R 2 _ C E N T R A L _ d t r a n . r v t 2/ 4 / 2 0 1 9 9 : 4 4 : 5 0 A M 1/4" = 1'-0" A2.1e 21833.00 VILLAGER #2 1001 E. COOPER AVENUE #2 ASPEN, CO. 81611 MAIN LEVEL EXISTING AND DEMO PLANS SCALE: PLAN NORTH TRUE NORTH A2.1e 1/4" = 1'-0" 1 EXISTING MAIN LEVEL FLOOR PLAN 02.15.2019 BUILDING PERMIT SCALE: PLAN NORTH TRUE NORTH A2.1e 1/4" = 1'-0" 2 MAIN LEVEL DEMO PLAN 2019-02-04 Residential Design Stds 02/25/2019 DW W/D DW W/D 1 1 3 3 A A C C 202 KITCHEN 206 DECK 101 STAIR 204 BATH OPEN TO BELOW 205 LAUNDRY 207 BEDROOM 208 CLOSET 20 ' - 1 " 38' - 8" REF STOR F.P HEARTH 201 LIVING DN B B 2 2 10' - 6 1/2"6' - 7"8' - 5"11' - 6" 17 ' - 1 " 2' - 7 " 10 ' - 2 1 / 2 " 4' - 4 1 / 4 " 15 ' - 8 3 / 4 " BEAM ABOVE SOFFIT ABOVE SOFFIT ABOVE MECHANICAL CHASE 202 DINING 1 1 3 3 A A C C 38' - 8" 20 ' - 1 " DN B B 2 2 FLOOR PLAN GENERAL NOTES - DEMOLITION 1.DEMOLITION SHALL BE LIMITED SOLELY TO ITEMS SPECIFICALLY SHOWN IN THE DRAWINGS. THE INTENT IS TO SHOW THE GENERAL SCOPE OF DEMOLITION REQUIRED TO PREPARE FOR THE RENOVATION. SEE ALL ARCHITECTURAL AND CONSULTANT DRAWINGS (INCLUDING, BUT NOT LIMITED TO: FLOOR PLANS, INTERIOR ELEVATIONS, DETAILS, AND SCHEDULES) FOR FULL EXTENT OF WORK. 2.ALL STRUCTURE, EXISTING TO REMAIN, SHALL BE PROPERLY SHORED AND/OR SUPPORTED IN ACCORDANCE WITH THE CONTRACTED STRUCTURAL ENGINEER’S “WAYS AND MEANS”GUIDELINES. CONTRACTORS TO ASSUME LIABILITY FOR SUCH MOVEMENT, SETTLEMENT, DAMAGE, OR INJURY RESULTING FROM DEMOLITION WORK. 3.COMPLY WITH ALL APPLICABLE LOCAL, STATE, AND FEDERAL CODES AS WELL AS REGULATIONS PERTAINING TO THE SAFETY OF ALL PERSONS, PROPERTY, AND ENVIRONMENTAL PROTECTION. 4.CEASE OPERATIONS IMMEDIATELY IF SAFETY OF STRUCTURE APPEARS TO BE ENDANGERED. DO NOT RESUME OPERATIONS UNTIL SAFE CONDITIONS ARE RESTORED. 5.VERIFY STRUCTURAL VIABILITY OF DEMOLITION IN FIELD. COORDINATE WITH ARCHITECT AND STRUCTURAL ENGINEER UPON REMOVAL OF FINISHES TO ASSESS CONDITIONS. 6.REMOVE FROM SITE AND LEGALLY DISPOSE OF REFUSE, DEBRIS, RUBBISH, AND OTHER MATERIALS, RECYCLING AS REQUIRED, RESULTING FROM DEMOLITION OPERATIONS DAILY. SITE TO BE LEFT BROOM CLEAN AND READY RO RECEIVE NEW FINISHES DAILY. 7.REMOVE ALL INTERIOR GYPSUM BOARD FROM WALLS AND CEILINGS AS REQUIRED FOR ABATEMENT AND PROPOSED WORK. 8.PATCH AND REPAIR DRYWALL AS NECESSARY. PATCH WALL AT ALL INTERSECTIONS OF DEMOLISHED WALLS. 9.EXISTING FIRE RATED ASSEMBLIES TO REMAIN INTACT OR REPAIRED TO MEET FIRE RATING. 10.NOTIFY OWNERS AND NEIGHBORS OF ANY UTILITY SHUT OFF OR INTERRUPTION OF SERVICE. 11.ALL SMOKE DETECTORS PER CITY OF ASPEN TO BE REPLACED WITH COMBINATION SMOKE/CARBON MONOXIDE DETECTORS. 12.SALVAGE ALL EXISTING EQUIPMENT AND FURNITURE. VERIFY W/ OWNER PRIOR TO REMOVAL. COORDINATE FOR STORAGE, RECYCLING OR LANDFILL. 13.EXISTING ELECTRICAL, LIGHTING, BRANCH WIRING/CIRCUITING, JUNCTION BOXES, ETC TO BE EVALUATED ON SITE FOR RE-USE OR REMOVAL AND REPLACEMENT. SEE ELECTRICAL DOCUMENTS. 14.EXISTING MECHANICAL/HVAC SYSTEM TO BE EVALUATED PER PARTIAL REUSE OR REMOVAL AND REPLACEMENT. SEE MECHANICAL DOCUMENTS. 15.EXISTING PLUMBING TO BE EVALUATED AND COORDINATED FOR PARTIAL RE- USE OR REMOVAL AND REPLACEMENT. SEE PLUMBING DOCUMENTS. FLOOR PLAN PHASING LEGEND EXISTING TO REMAIN EXISTING PARTITION, MILLWORK, FIXTURE, OR WALL TO BE REMOVED rowland+broughton architecture / urban design / interior design 234 e. hopkins ave. aspen, co 81611 970.544.9006 o 970.544.3473 f 1830 blake st. ste. 200 denver, co 80202 303.308.1373 o 303.308.1375 f Consultants: Issuances and Revisions: COPYRIGHT 2019 ROWLAND + BROUGHTON ARCHITECTURE AND URBAN DESIGN THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS THE PROPERTY OF ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN. NO PART OF THIS INFORMATION MAY BE USED WITHOUT THE PRIOR WRITTEN PERMISSION OF ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN. ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN SHALL RETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING COPYRIGHT THERETO. SCALE: SHEET TITLE: PROJECT NO: Fi l e P a t h : Pl o t D a t e :NOT FOR CONSTRUCTIONC: \ U s e r s \ d t r a n \ D o c u m e n t s \ 2 1 8 3 3 . 0 0 _ V I L L A G E R 2 _ C E N T R A L _ d t r a n . r v t 2/ 4 / 2 0 1 9 9 : 4 4 : 5 2 A M 1/4" = 1'-0" A2.2e 21833.00 VILLAGER #2 1001 E. COOPER AVENUE #2 ASPEN, CO. 81611 UPPER LEVEL EXISTING AND DEMO PLANS SCALE: PLAN NORTH TRUE NORTH A2.2e 1/4" = 1'-0" 1 EXISTING UPPER LEVEL FLOOR PLAN 02.15.2019 BUILDING PERMIT SCALE: PLAN NORTH TRUE NORTH A2.2e 1/4" = 1'-0" 2 UPPER LEVEL DEMO PLAN 2019-02-04 Residential Design Stds 02/25/2019 UP W/ D UP W/ D A4.1 1 1 1 3 3 A A C C 38' - 8" 20 ' - 1 " TV TV 101 ENTRY 102 GYM 105 HALL 103 BATH 104 CLOSET 107 STAIR 108 MECHANICAL 111 CLOSET 109 LAUNDRY OPEN TO EGRESS WELL ABOVE BUILT-IN LOUNGE SEAT ST O R A G E 106 HALLMECHANICAL CHASE DECK ABOVE CEILING ABOVE 110 MUD ROOM WEIGHTS & EQUIPMENT B B 2 2 112 BED 113 BATH 114 CLOSET 1/110 2/110 2/112 1/105 1/102 1/103 2/103 1/104 1/107 1/111 1/109 1/113 2/113 1/114 1/112 1/101 EXISTING EXTERIOR DOOR TO REMAIN 4' - 4 1 / 4 " 15 ' - 8 3 / 4 " 31' - 2 1/4"7' - 5 3/4" 1' - 8 3 / 1 6 " 5' - 1 3/4"2' - 6"2' - 10"6' - 8 1/4" EXISITING STAIRS TO REMAIN 8' - 10 1/4"5' - 7 3/4"2' - 6"2' - 9 1/2" 4' - 1 1 5 / 8 " 10' - 7 3/4"8' - 9 3/4"11' - 5 3/8"5' - 10 1/4" 4' - 1 1 5 / 8 " 3' - 1 1 / 4 " 6' - 5 7 / 8 " 7' - 4 5 / 8 " 3' - 2 3/8" 4' - 1 1 5 / 8 " 2' - 7 1 / 2 " 2' - 1 0 7 / 8 " 01 02 3' - 4 1/8"7' - 9 1/8" A4.1 2 A4.1 3 1 1 3 3 A A C C A9.14 1 2 3 WEIGHTS & EQUIPMENT 38' - 8" 20 ' - 1 " 101 ENTRY 102 GYM 105 HALL 108 MECHANICAL 107 STAIR 104 CLOSET 103 BATH 109 LAUNDRY 111 CLOSET A9.28 5 6 7 106 HALL A9.2A9.1 7 5 8 6 A9.112 9 10 11 A9.1 1314 A9.24 1 2 3 A9.3 7 5 8 6 A9.3 1 24 3 A9.44 1 2 3 A9.4 5 68 7 A9.410 9 A9.4 12 11 14 13 A9.2 13 11 1214 9 10 QUEEN OPEN TO EGRESS WELL ABOVE BUILT-IN BENCH MECHANICAL CHASE DECK ABOVE CEILING ABOVE TV 110 MUD ROOM T1RB RB T1 RB T1 CPTT1 CP T T1 T1 CP T B B 2 2 T1 TB D 113 BATH 114 CLOSET 112 BED TV CP T CP T 4' - 4 1 / 4 " 15 ' - 8 3 / 4 " 31' - 2 1/4"7' - 5 3/4" A4.1 2 A4.1 3 FLOOR PLAN GENERAL NOTES 1.ARCHITECTURAL 100’-0”= TOP OF EXISTING STRUCTURE. 2.ALL DIMENSIONS AND CONDITIONS SHOULD BE VERIFIED. NOTIFY THE ARCHITECT OF ANY INCONSISTENCIES OR OTHER PROBLEMS DISCOVERED IMMEDIATELY BEFORE PROCEEDING WITH THE WORK. 3.DIMENSIONS ARE TAKEN FROM COLUMN CENTER LINES AND THE FACE OF FINISH UNLESS NOTED OTHERWISE. 4.CLEAR DIMENSIONS ARE TO BE FINISHED FACE AND SHALL TAKE PRECEDENCE OVER ANY OTHER DIMENSION. 5.GC TO PROVIDE RADON MITIGATION IN ACCORDANCE WITH ALL APPLICABLE CODES. 6.GC TO PROVIDE ALL SMOKE DETECTORS AND CARBON MONOXIDE DETECTORS IN ACCORDANCE WITH ALL APPLICABLE CODES AND LOCAL ORDINANCES. 7.REFER TO DOOR AND WINDOW SCHEDULES FOR ADDITIONAL INFORMATION. 8.GC TO REVIEW PLACEMENT OF ALL FLOOR OUTLETS, TELEPHONE PORTS, AND DATA PORTS WITH OWNER AND ARCHITECT PRIOR TO ROUGH-IN. 9.SEE STRUCTURAL DRAWINGS FOR ALL STRUCTURAL LOCATIONS AND SIZING. IN THE CASE OF ANY CONFLICTS, STRUCTURAL DRAWINGS TAKE PRECEDENCE. NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK. 10.REFER TO ELEVATIONS FOR ADDITIONAL WINDOWS NOT SHOW OR TAGGED IN PLAN. rowland+broughton architecture / urban design / interior design 234 e. hopkins ave. aspen, co 81611 970.544.9006 o 970.544.3473 f 1830 blake st. ste. 200 denver, co 80202 303.308.1373 o 303.308.1375 f Consultants: Issuances and Revisions: COPYRIGHT 2019 ROWLAND + BROUGHTON ARCHITECTURE AND URBAN DESIGN THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS THE PROPERTY OF ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN. NO PART OF THIS INFORMATION MAY BE USED WITHOUT THE PRIOR WRITTEN PERMISSION OF ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN. ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN SHALL RETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING COPYRIGHT THERETO. SCALE: SHEET TITLE: PROJECT NO: Fi l e P a t h : Pl o t D a t e :NOT FOR CONSTRUCTIONC: \ U s e r s \ d t r a n \ D o c u m e n t s \ 2 1 8 3 3 . 0 0 _ V I L L A G E R 2 _ C E N T R A L _ d t r a n . r v t 2/ 4 / 2 0 1 9 9 : 4 2 : 3 3 A M 1/4" = 1'-0" A2.1 21833.00 VILLAGER #2 1001 E. COOPER AVENUE #2 ASPEN, CO. 81611 PROPOSED MAIN LEVEL FLOOR PLANS SCALE: PLAN NORTH TRUE NORTH A2.1 1/4" = 1'-0" 1 MAIN LEVEL FLOOR PLAN 02.15.2019 BUILDING PERMIT SCALE: PLAN NORTH TRUE NORTH A2.1 1/4" = 1'-0" 2 MAIN LEVEL FINISH PLAN 2019-02-04 Residential Design Stds 02/25/2019 DW ART DW ART A4.1 1 1 1 3 3 A A C C REF TV TV 107 STAIR 202 KITCHEN OPEN TO BELOW ST O R A G E SH E L V I N G 203 MASTER BED HEARTH F.P 20 ' - 1 " 38' - 8" UC REF 201 GREAT ROOM SH E L V I N G SH E L V I N G 206 TOILET DN B B 2 2 205 MASTER CLOSET 204 MASTER BATH STORAGE MECHANICAL CHASE PRINTER A6.4 3 A6.5 2 09 1/204 2/204 1/206 RIDGE ABOVE 4' - 4 1 / 4 " 15 ' - 8 3 / 4 " 31' - 2 1/4"7' - 5 3/4" 08 4' - 11 7/8" EXISTING FURRED WALL FOR DRAINAGE TO REMAIN NEW FURRED WALL TO ALIGN W/ EXISTING 12' - 11 1/4" CONVERT WOOD BURNING F.P. TO GAS 5' - 8 5/8"7' - 1" 10' - 7 1/8"6' - 8 1/4" EXISTING STAIRS TO REMAIN 2' - 6 3/8"5' - 5 7/8"5' - 0"6' - 0 1/4" 2' - 6 " 13 ' - 2 7 / 8 " 5' - 6 1 / 2 " CLEAR 3' - 0" 12' - 8 3/8" 7' - 4 5/8" 7' - 9 7/8" 20' - 7 3/8"9' - 9 7/8" 3' - 5 1/8" 2' - 7 1/8"NEW FURRED WALL TO ALIGN WITH EXSITING 3' - 3" CLEAR 3' - 0" SPRING POINT OF ROOF ABOVE 8' - 10 5/8" 4' - 7" 4' - 10 1/4" 1/201 06 07 A4.1 2 A4.1 31' - 8 1/2" EQ EQ FLOOR PLAN GENERAL NOTES 1.ARCHITECTURAL 100’-0”= TOP OF EXISTING STRUCTURE. 2.ALL DIMENSIONS AND CONDITIONS SHOULD BE VERIFIED. NOTIFY THE ARCHITECT OF ANY INCONSISTENCIES OR OTHER PROBLEMS DISCOVERED IMMEDIATELY BEFORE PROCEEDING WITH THE WORK. 3.DIMENSIONS ARE TAKEN FROM COLUMN CENTER LINES AND THE FACE OF FINISH UNLESS NOTED OTHERWISE. 4.CLEAR DIMENSIONS ARE TO BE FINISHED FACE AND SHALL TAKE PRECEDENCE OVER ANY OTHER DIMENSION. 5.GC TO PROVIDE RADON MITIGATION IN ACCORDANCE WITH ALL APPLICABLE CODES. 6.GC TO PROVIDE ALL SMOKE DETECTORS AND CARBON MONOXIDE DETECTORS IN ACCORDANCE WITH ALL APPLICABLE CODES AND LOCAL ORDINANCES. 7.REFER TO DOOR AND WINDOW SCHEDULES FOR ADDITIONAL INFORMATION. 8.GC TO REVIEW PLACEMENT OF ALL FLOOR OUTLETS, TELEPHONE PORTS, AND DATA PORTS WITH OWNER AND ARCHITECT PRIOR TO ROUGH-IN. 9.SEE STRUCTURAL DRAWINGS FOR ALL STRUCTURAL LOCATIONS AND SIZING. IN THE CASE OF ANY CONFLICTS, STRUCTURAL DRAWINGS TAKE PRECEDENCE. NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK. 10.REFER TO ELEVATIONS FOR ADDITIONAL WINDOWS NOT SHOW OR TAGGED IN PLAN. 1 1 3 3 A A C C A9.5 1 2 3 4 A9.5 5 6 7 8 A9.64 1 2 3 A9.6 5 6 7 8A9.610 9 A9.7 2 1 4 3 203 MASTER BED 202 KITCHEN 107 STAIR 201 GREAT ROOM OPEN TO BELOW UC REFHEARTH FP SH E L V I N G SH E L V I N G SH E L V I N G TV TV REF 38' - 8" 20' - 1" QUEEN MECHANICAL CHASE 206 TOILET A9.7 5 6 7 8 DN ST O R A G E B B 2 2 205 MASTER CLOSET 204 MASTER BATH STORAGE W D T1 PRINTER RIDGE ABOVE 4' - 4 1/4" 15' - 8 3/4" 31' - 2 1/4"7' - 5 3/4" A4.1 2 A4.1 3 rowland+broughton architecture / urban design / interior design 234 e. hopkins ave. aspen, co 81611 970.544.9006 o 970.544.3473 f 1830 blake st. ste. 200 denver, co 80202 303.308.1373 o 303.308.1375 f Consultants: Issuances and Revisions: COPYRIGHT 2019 ROWLAND + BROUGHTON ARCHITECTURE AND URBAN DESIGN THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS THE PROPERTY OF ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN. NO PART OF THIS INFORMATION MAY BE USED WITHOUT THE PRIOR WRITTEN PERMISSION OF ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN. ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN SHALL RETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING COPYRIGHT THERETO. SCALE: SHEET TITLE: PROJECT NO: Fi l e P a t h : Pl o t D a t e :NOT FOR CONSTRUCTIONC: \ U s e r s \ d t r a n \ D o c u m e n t s \ 2 1 8 3 3 . 0 0 _ V I L L A G E R 2 _ C E N T R A L _ d t r a n . r v t 2/ 4 / 2 0 1 9 9 : 4 2 : 3 4 A M 1/4" = 1'-0" A2.2 21833.00 VILLAGER #2 1001 E. COOPER AVENUE #2 ASPEN, CO. 81611 PROPOSED UPPER LEVEL FLOOR PLANS 02.15.2019 BUILDING PERMIT SCALE: PLAN NORTH TRUE NORTH A2.2 1/4" = 1'-0" 1 UPPER LEVEL FLOOR PLAN SCALE: PLAN NORTH TRUE NORTH A2.2 1/4" = 1'-0" 2 UPPER LEVEL FINISH PLAN 2019-02-04 Residential Design Stds 02/25/2019 rowland+broughton architecture / urban design / interior design 234 e. hopkins ave. aspen, co 81611 970.544.9006 o 970.544.3473 f 1830 blake st. ste. 200 denver, co 80202 303.308.1373 o 303.308.1375 f Consultants: Issuances and Revisions: COPYRIGHT 2018 ROWLAND + BROUGHTON ARCHITECTURE AND URBAN DESIGN THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS THE PROPERTY OF ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN. NO PART OF THIS INFORMATION MAY BE USED WITHOUT THE PRIOR WRITTEN PERMISSION OF ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN. ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN SHALL RETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING COPYRIGHT THERETO. SCALE: SHEET TITLE: PROJECT NO: Fi l e P a t h : Pl o t D a t e :NOT FOR CONSTRUCTIONC: \ U s e r s \ d t r a n \ D o c u m e n t s \ 2 1 8 3 3 . 0 0 _ V I L L A G E R 2 _ C E N T R A L _ d t r a n . r v t 2/ 4 / 2 0 1 9 1 0 : 1 0 : 5 4 A M A1.1 21833.00 VILLAGER #2 1001 E. COOPER AVENUE #2 ASPEN, CO. 81611 SITE PLAN 02/25/2019