HomeMy WebLinkAboutFile Documents.110 Coach Rd.0079.2018 (61).ARBKWELS Markup 110 Coach Rd Page: [1] IR-DBX Lot 7-L.2.03 Author: rickma Date: 2/4/2019 1:04:21 PM File Name: IRRIGATION_10-19-18.pdf Please include the irrigation valves for each hydrozone, such as: (A3,A7,A8, etc.) [1] IR-DBX Lot 7-L.2.03 (2) Page: [1] IR-DBX Lot 7-L.2.03 Author: rickma Date: 2/4/2019 1:03:56 PM File Name: IRRIGATION_10-19-18.pdf Please add the language of WELS Section 4.3.2 (l & m) regarding disturbance under existing trees Page: [2] C1D-DBX7-LANDSCAPE SHEETSET-LNTS Author: rickma Date: 2/4/2019 1:01:26 PM File Name: L_LANDSCAPE.pdf Revise to be consistent with WELS Section 4.2 [2] C1D-DBX7-LANDSCAPE SHEETSET-LNTS (1) Please include the irrigation valves for each hydrozone, such as: (A3,A7,A8, etc.) Please add the language of WELS Section 4.3.2 (l & m) regarding disturbance under existing trees SPECIA ·GENER STRUC INCLUD ·CONCR INTRICA OF THE ·NOTES FILLER RIGIDLY ·SUBGR AREAS ·ALL RE PRIOR THE TH UTILIZE ·SLEEVE ·ULTIMA ·CONCR ·CONCR TEMPE PONSIBLE FOR PROVIDING PLANTS, SPACED AS SPECIFIED ON THE PLANT S IN PLANTING BEDS, SPACING OF MATERIAL SHALL TAKE PRECEDENCE OVER TED FOR PLANTING AREAS. NOTIFY LANDSCAPE ARCHITECT IMMEDIATELY IF AND GROUNDCOVER SPACING IS GENERALLY INDICATED ON THE PLANT LIST ENT SHRUBS AND TREES THAT ARE NOT PART OF MASS PLANTINGS SHALL BE S. HALL BE RESPONSIBLE FOR THE STABILITY AND PLUMB CONDITION OF ALL D REPLACING ANY DAMAGED PLANT MATERIAL. WITH PLANTS OF EQUAL KIND, TIONAL COST TO THE OWNER. NO CHAINS OR CABLES SHALL BE USED WHEN SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PREVENT PLANTS AND BLOWN OVER, AND TO REPLACE ALL PLANTS WHICH ARE DAMAGED DUE TO G, AT NO ADDITIONAL COST TO THE OWNER. THE CONTRACTOR SHALL S THE END OF THE WARRANTY PERIOD AND DISPOSE OFFSITE. OP-DRESSED WITH A 3" LAYER OF MULCH AS SPECIFIED. ALL TREES SHALL ACED AROUND THE BASE OF THE TRUNK. THE LANDSCAPE SCOPE OF WORK GRAL PART THE PROJECT AND NOT AS A SEPARATE COST OR WORKS ITEM. CEIVE ADEQUATE WATERING BY THE LANDSCAPE CONTRACTOR AS REQUIRED ON SYSTEM IS FULLY OPERATIONAL AND UNTIL FINAL ACCEPTANCE BY MAIN WITHIN THE CONSTRUCTION LIMIT LINE SHALL BE LEFT UNDISTURBED. NOTED ON THE DRAWINGS, SHALL BE LEFT UNDISTURBED AND PROTECTED ION FENCING ERECTED AT THE PERIMETER OF THE TREE DRIP LINE (S). NO AREA NOR SHALL ANY STORAGE OF MATERIALS OR EQUIPMENT BE F THE TREE DRIPLINE(S). ANY EXISTING PLANT BEDS OR TREES DAMAGED BY BE REPLACED BY THE RESPONSIBLE PARTY AT THEIR OWN EXPENSE. THIN DESIGNATED UTILITY CORRIDORS, PUBLIC RIGHT OF WAY (WITHOUT MIT). FIELD ADJUST AS NECESSARY AND REVIEW ADJUSTMENTS WITH THE O INSTALLATION. Revise to be consistent with WELS Section 4.2 Page: [2] IR-DBX Lot 7-L.2.04 Author: rickma Date: 2/4/2019 10:55:18 AM File Name: IRRIGATION_10-19-18.pdf A lockable master valve is required as per WELS Section 5.1.3 [2] IR-DBX Lot 7-L.2.04 (1) Page: [6] C1D-DBX7-LANDSCAPE SHEETSET-L.2.04 Author: rickma Date: 2/4/2019 11:16:12 AM File Name: L_LANDSCAPE.pdf Consider adding native forbs to the revegetation seed mix to promote more species diversity. [6] C1D-DBX7-LANDSCAPE SHEETSET-L.2.04 (3) Page: [6] C1D-DBX7-LANDSCAPE SHEETSET-L.2.04 Author: rickma Date: 2/4/2019 11:27:35 AM File Name: L_LANDSCAPE.pdf Isn't Ecoloturf a medium water use sod once established? Page: [6] C1D-DBX7-LANDSCAPE SHEETSET-L.2.04 Author: rickma Date: 2/4/2019 11:27:41 AM File Name: L_LANDSCAPE.pdf Why are P. virginiana, P. tremuloides, and P. ponderosa on "temporary tree drip-low" in Hydrozone 3? A1 12.5 0.20 1" P F K R R R A lockable master valve is required as per WELS Section 5.1.3 REVEGETAT Achnatherum Bromus marg Elymus lance Elymus trach Festuca idah Nassella virid Pascopyrum Pseudoroegn SOD - ECOL - Consider adding native forbs to the revegetation seed mix to promote more species diversity. 1 Isn't Ecoloturf a medium water use sod once established? 77 5 4 77 5 5 SYMBOL DESCRIPTION HYDROZONE 1 - TEMP. IR HYDROZONE 2 - PERM. IR HYDROZONE 3 - TEMP. TR HYDROZONE 4 - TREE DR HYDROZONE 5 - ECOLOTU HYDROZONES SCHEDU 1 1 5 7 6 1 3 4 5 2 2 Why are P. virginiana, P. tremuloides, and P. ponderosa on "temporary tree drip-low" in Hydrozone 3?