HomeMy WebLinkAboutFile Documents.1112 Waters Ave.0024.2019 (15).ARBK1112 Waters Ave ‐ WELS Comments 02.26.2019 Written Responses 03.08.2019
Page: [1] IR 1112 Waters Ave‐IR1.0
Revise all WELS section numbering to be consistent with the latest version of WELS
Response: SECTION NUMBERS UPDATED
Page: [1] IR 1112 Waters Ave‐IR1.0
Cool Season Turf is VH @ .90 plant factor. Revise accordingly.
Response: GRASS AREA TO MATCH EXISTING HIGH- WATER SPECIES
Page: [1] IR 1112 Waters Ave‐IR1.0
Include the language of WELS Section 4.3.2 (m). regarding disturbance under existing trees. Please note
that the City Forester requires that cutting roots larger than 2" in diameter is not permitted.
Response: LANGUAGE UPDATED
Page: [2] IR 1112 Waters Ave‐IR1.1
Include the language of WELS Section 4.3.2 (m) regarding irrigation work done under existing trees.
Response: LANGUAGE UPDATED
Page: [2] IR 1112 Waters Ave‐IR1.1
These head appear to be on a neighboring property.
Response: HEADS RELOCATED
Page: [2] IR 1112 Waters Ave‐IR1.1
Update WELS citations to most recent numbering, which can be found on the CoA website
Response: SECTIONS UPDATED
4/10/2019
Page: [2] IR 1112 Waters Ave‐IR1.1
WELS Section 5.2.3 states that areas less than 10 feet in any direction should not use overhead sprinkler
irrigation. The Planting Plan indicates a narrow strip of turf in this location
Response: IRRIGATION TO SERVE LIMITS OF NEWLY PLANTED GRASS ALONG DRIVE TO MATCH EXISTING SPECIES
THROUGHOUT.
Page: [3] BG_IZ_L Series‐L002 NOTES
Include the language of WELS Section 4.2‐ Mulch Criteria
Response: The WELS mulch criteria language has been added to the notes.
Page: [7] BG_IZ_L Series‐L400
Cool Season Turf is Very High water. Revise.
Response: Sod has been clarified as fescue mix to match existing high water use species.
4/10/2019