HomeMy WebLinkAboutFile Documents.728 E Hopkins Ave.0186.2019 (31).ARBK 0186-2019-arbk_building comments_1
Bubbled Architectural Plan Set.728 E Hopkins Ave.2019.07.pdf(3)
o - Subject: PlanCheck
�.
AI �o E. o . A guardrail adjacent to a spa
o . Page Label: [1]A-120 PROPOSED UPPER LEVEL FLOOR
III �--1 o - must be 18F'above the top of the
e - PLAN
��ill o - g spa. Please provide a detail
IIEll e • Page Index: 14
EE,LLS _,_ 11` o® :
Author: tonyf demonstrating that this guardrail
�___ Date: 8/29/2019 11:24:27 AM complies
o : File Name: Bubbled Architectural Plan Set.728 E Hopkins
o : Ave.2019.07.pdf
o -
Subject: PlanCheck
Page Label: [1]A-202 EXTERIOR ELEVATIONS Refer note on sheet A-120
Page Index: 17
Author: tonyf
Date: 8/29/2019 11:23:01 AM
missasiv_ M<F File Name: Bubbled Architectural Plan Set.728 E Hopkins
"°""°-°"''°a''�"...., °K^ Ave.2019.07.pdf
Subject: PlanCheck
® fib Page Label: [1]A-501 ASSEMBLY DETAILS Show all roof drains. Provide
^,°, TYP.EXTERIOR DECK RAILING Page Index: 18 secondary drains or scuppers
Author: tonyf where the roof perimeter could
Pa ;rya.narvry N =_ Date: 8/29/2019 11:31:24 AM trap water if the primary drains
µ,1p=
— — File Name: Bubbled Architectural Plan Set.728 E Hopkins clog. Secondary drains must be
El E ._ Ave.2019.07.pdf above the primary drain inlet but
ASSFM9l
�S tia DFLAILS
below window and door
thresholds. Secondary drains
require separate plumbing and
a termination location above
grade that can be observed by
occupants. Show the location of
the primary drains and the
secondary drains and their outlet
terminations. (2015 IPC 1108