Loading...
HomeMy WebLinkAboutFile Documents.728 E Hopkins Ave.0186.2019 (31).ARBK 0186-2019-arbk_building comments_1 Bubbled Architectural Plan Set.728 E Hopkins Ave.2019.07.pdf(3) o - Subject: PlanCheck �. AI �o E. o . A guardrail adjacent to a spa o . Page Label: [1]A-120 PROPOSED UPPER LEVEL FLOOR III �--1 o - must be 18F'above the top of the e - PLAN ��ill o - g spa. Please provide a detail IIEll e • Page Index: 14 EE,LLS _,_ 11` o® : Author: tonyf demonstrating that this guardrail �___ Date: 8/29/2019 11:24:27 AM complies o : File Name: Bubbled Architectural Plan Set.728 E Hopkins o : Ave.2019.07.pdf o - Subject: PlanCheck Page Label: [1]A-202 EXTERIOR ELEVATIONS Refer note on sheet A-120 Page Index: 17 Author: tonyf Date: 8/29/2019 11:23:01 AM missasiv_ M<F File Name: Bubbled Architectural Plan Set.728 E Hopkins "°""°-°"''°a''�"...., °K^ Ave.2019.07.pdf Subject: PlanCheck ® fib Page Label: [1]A-501 ASSEMBLY DETAILS Show all roof drains. Provide ^,°, TYP.EXTERIOR DECK RAILING Page Index: 18 secondary drains or scuppers Author: tonyf where the roof perimeter could Pa ;rya.narvry N =_ Date: 8/29/2019 11:31:24 AM trap water if the primary drains µ,1p= — — File Name: Bubbled Architectural Plan Set.728 E Hopkins clog. Secondary drains must be El E ._ Ave.2019.07.pdf above the primary drain inlet but ASSFM9l �S tia DFLAILS below window and door thresholds. Secondary drains require separate plumbing and a termination location above grade that can be observed by occupants. Show the location of the primary drains and the secondary drains and their outlet terminations. (2015 IPC 1108