Loading...
HomeMy WebLinkAboutFile Documents.614 North St.0224.2018 (12).ARBK 0224-2018-ARBK_BuildingComment Arch Permit Set.pdf(3) Subject: PlanCheck �/ ° I®� 8 €'�.. r This fireplace wall is pushing out h may- Page Label: 6 further than the original, the roof I Author:justinh plan should also be revised to 1_1 __ �l 4' - File Name: Arch Permit Set.pdf .wP.,N;" w ,gill �� � 'l . conw a sently. vplace aepl c ° • consistently. Provide fireplace � �� _ FP Response: The roof plan has been revised to det 'I h ing c mpl� ith g;';;01 - show the new fireplace correctly. Exterior walls of the installation instructions for b b b b the fireplace are canted, which decreases the this gas log fireplace(chimney ". overall width of the termination at the chimney termination, hearth extension, cap. An enlarged fireplace plan and sectional clearance to combustibles, etc). drawings have been provided on sheet A-403. The From what I can tell from the revised Fireplace now meets the IRC clearance elevations you do not meet the 2' requirement of Table R1001.1 (R) above any structure within 10' requirement in the provided installation instructions. h -_ Subject: PlanCheck✓ - Page Label: 11 Is the garage unconditioned? It =i Author:justinh was not shown as such in the s��'�i` %p w File Name:Arch Permit Set.pdf original permit drawings but F5 °�I"�' I, -__�--. p shows it as such. If that is the 11 - FP Response: The garage will be conditioned case then then F5 would need to © ©© space. W3 will remain as the thermal envelope at be insulated to R49 as a ceiling =I--1Pla- .M.. o the garage. Reference A-501 for an updated F-5 since it is proposed to be altered 1 ..n..ee.n....w_F1N o ,; -4- ° ©g assembly showing both spaces are conditioned. and F4 would need to be R38 if .111•- ;t , o Reference details 3 and 8 on Sheet A-502 it is being altered. This would showing the existing assemblies, W-3 and R-1 to also move the thermal envelope be insulated with spray foam. Section A on sheet to be at W6 rather than W3. A-301 also shows correct assemblies at the Please verify whether this space is conditioned and revise if garage. needed. ,,��d !UDD'7atP-_=__; Subject: PlanCheck I 4_11 Page Label: 14 This maximum opening needs to ®°�i'!'It<`' _mm - Author:justinh be less than 4"so that it restricts ult __- -- the passage of a 4"sphere, ,i,, . File Name: Arch Permit Set.pdf - /•Bol� please revise. WI� ��'' u FP Response: A glass guard will now be installed i.1, EIiII 'm�='�; �� 011- i'�,-- instead of the lattice system previously shown. A :� 111 nl' Ijl specification sheet for the glass guard railing ! __ system has been provided. This glass guard w- complies with COA 8.16.020(s) and Table R301.5. Reference sheet A-401 for updated stair drawings. Structual Permit Set.pdf(1) I ! , e 1 __ Subject: PlanCheck ✓ 1. ' i , I I I I' �r Page Label: 3 Is the 4"slab completely IH. g supported bynon combustible of ,ms. ... Author:justinh pp �� "°- construction? The 2x8 ledger _i .i. �— File Name: Structual Permit Set.pdf M--- 'L , 01mw, =� ,v .- note makes me question this. 1 "'°"°'" 1 FP Response: The 4" slab is not supported by non Please clarify and revise if combustible construction. This slab is on grade, needed. additionally supported by the new basement wall b b b b below and cantilevered for the hearth extension. The 2x8 Ledger is to support the new wood framing on the main level. Reference detail 1, on A-403 which shows a section of this condition.