File Documents.1250 Snowbunny Ln.0040.2018 (24).ARBK
Environmental 4 Disaster Restoration , Inc . ECOS Environmental - Glenwood Springs 6690 Hwy 82 Glenwood Springs, CO 81601 Office - (970) 945-4407 info@ecosenvironmental.com www.ecosenvironmental.com ASBESTOS INSPECTION REPORT CLIENT: Phil Altfeld ADDRESS: 1250 Snowbunny Lane CITY/STATE: Aspen, CO 81611 EMAIL: daltfeldabsouthernlandcompany.com PHONE: 970-927-1780 PROJECT LOCATION: 1250 Snowbunny Lane Aspen,CO 81611 DATE OF INSPECTION: September 15,2017 GWS Office: (970)945-4407• Aspen Office: (970)925-3267 RECEIVED 6690 Hwy 82,Glenwood Springs,CO 81601 • 401 Aspen Airport Business Center, Aspen,CO U �1—7/2 018 Email: info@ecosenvironmental.com • www.ecosenvironmental.com ASPEN BUILDING DEPARTMENT ecos Environmental Disaster Restoration,Inc. ECOS Environmental & Disaster Restoration(ECOS) was retained to conduct a limited asbestos inspection at the above location to determine if asbestos is present prior to planned renovations in the residence. The inspection included all accessible building materials however, should additional building materials be discovered during the renovation, those materials must be sampled and analyzed prior to continuing with the work. Fifteen samples were collected of all suspect materials identified throughout the residence, as listed in the Lab Data table located on page 8 of this report. INSPECTOR OUAT IFTr ATTCNS This inspection was performed by Brian Guzman, Colorado State Department of Public Health and Environment Certification Number 21876. S.AMPT F AN AT YSTS PROCFnT TV Suspect material was sampled and delivered under a chain of custody for analysis to Aerobiology Laboratory in Golden, CO. Samples were analyzed by Polarized Light Microscopy. TRANSMITTAT. OF BUTT.DTNG/STRUCTURF ASBFSTOS SURVFY INFORMATION One (1) copy of the results of the building/structure asbestos survey shall be immediately transmitted by the building/structure owner as follows: • One copy of the completed asbestos survey shall be sent by the owner or their agent to the local government entity charged with issuing a permit for such demolition, renovation, remodeling or repair work under applicable State or local laws. • The completed asbestos survey shall be kept on the construction site with the asbestos notification and variance, if required, throughout the duration of the asbestos project and any associated demolition, renovation, remodeling or repair project. The asbestos survey shall, at a minimum, identify and assess with due diligence, the locations, quantities, friability and conditions of all building material types at the affected portion of the building/structure. The certified asbestos inspector is responsible for identification and assessment of all type within the affected portion of the building/structure. All building materials visually assessed shall be assumed to be asbestos containing material (ACM), unless bulk sampling is conducted as per standard EPA and OSHA accepted ^ IV �GWS Office: (970) 945-4407 Aspen Office: (970) 925-3267 R 4 6690 Hwy 82,Glenwood Springs,CO 81601 • 401 Aspen Airport Business Center,Aspen,CO 6.610 7/2 018 Email: info©ecosenvironmental.com • www.ecosenvironmental.com ASPEN BUILDING DEPARTMENT ecos Gnvimilmontal Disaster 12estoration,Inc. methodologies. The subsequent analysis is performed by a laboratory that meets the requirements and the analyses satisfies both CO STATE ELAP and federal requirements, including multi-layered sample analyses, to document non-asbestos containing material. The building/structure asbestos survey shall also include the building/structure name, address, the building/structure owner's name and address, the name and address of the owner's agent, the name of the firm performing the asbestos survey and a copy of the firm's current asbestos handling license, the names of the certified inspector(s) performing the survey and a copy of the current asbestos handling certificate for each inspector utilized, the dates of the asbestos survey, a listing of homogeneous areas identifying which ones are ACM, all laboratory analysis reports for bulk samples collected, and copies of the appropriate certifications for the laboratory used for analysis of samples taken during the asbestos survey. REMOVAL REQUIREML. If the building/structure asbestos survey finds that the portion of the building/structure to be demolished,renovated, remodeled, or have repair work contains asbestos containing material (ACM), which is impacted by the work, the owner or the owner's agent shall conduct, or cause to have conducted, asbestos removal performed by a licensed asbestos abatement contractor in conformance with all standards set forth. All ACM impacted by the demolition, renovation, remodeling or repair project shall be removed, prior to access or disturbance by other uncertified trades or personnel. No demolition, renovation, remodeling or repair work shall be commenced by any owner or the owner's agent prior to the completion of the asbestos abatement in accordance with the notification requirements. For multi-phased work, the access restriction for uncertified trades or personnel applies to each intermediate portion of the entire project. Upon completion of the intermediate portion of the asbestos project, other trades, or personnel may access that portion of the work site. For demolition projects that are exempt from asbestos survey requirements due to being structurally unsound, the demolition is considered an asbestos project. All building/structure owners and asbestos abatement contractors on a demolition, renovation, remodeling, or repair project shall inform all trades on the work site about the ACM at the work site. UNIDENTIFIED AND UNASSESSLD ASHES OS When any construction activity,such as demolition, remodeling, renovation or repair work, reveals suspect ACM that has not been identified by the asbestos survey, or has not been identified by other inspections as per current OSHA or EPA requirements, all activities shall cease in the area where the suspect ACM is found. Unassessed suspect miscellaneous GWS Office: (970)945-4407 • Aspen Office: (970)925-3267 RECEIVED 6690 Hwy 82,Glenwood Springs,CO 81601 • 401 Aspen Airport Business Center, Aspen,CO 3"O 7/2 O 18 Email: info@ecosenvironmental.com • www.ecosenvironmental.com // ASPEN BUILDING DEPARTMENT e o s Environmental Disaster Restoration,Inc. ACM shall be treated and handled as ACM and assumed to be ACM, unless proven otherwise by standard EPA and OSHA accepted methods. To document non-asbestos containing material, analysis must be performed by a laboratory that meets the requirements of the DOH; and the analysis satisfies both CO STATE FLAP and federal requirements. ASBESIUSI-RUILL!S An asbestos project is any work that involves the removal, encapsulation, enclosure, repair or disturbance of friable or non-friable asbestos, or any handling of asbestos material that may result in the release of asbestos fibers. For the purpose of compliance an asbestos project shall include any disturbance of asbestos fibers, and the planning, asbestos survey, design, background air sampling, inspection, air sampling and oversight of abatement work, cleanup, and the handling of all asbestos material subject to abatement, as well as the supervising of such activities. An asbestos project starts with Phase I when the planning, asbestos survey, and design work begins or is required to begin. The project shall not be considered completed until Phase II D is complete. (See Table 1 below). Phase I (Prior to Asbestos Phase II Abatement Contractor) Start-> Abatement-> End A B A B C D Regulated Asbestos Final Asbestos abatement handling cleaning Final survey, Background work area(s) including gross and waste air removal or planning, preparation clearance removal and design sampling and enclosure abatement, air from site initial cleans, construction and waste samples Start-> Asbestos Project->Final Clearance GWS Office: (970)945-4407■ Aspen Office: (970)925-3267 RECEIVED 6690 Hwy 82,Glenwood Springs,CO 81601. 401 Aspen Airport Business Center,Aspen,CO oil/ 7/2 018 Email:info@ecosenvironmental.com• www.ecosenvironmental.com ASPEN BUILDING DEPARTMENT e g o s ASBESTOS RESULTS FLOW CHART Environmental Disaster Restoration,Inc. Asbestos Test -----I 10 Non Detect < 1% 1114111111111L-- No Action I OSHA I Reg. 8 dditional Reg. 8 Required Requirements Requirements Requirements 4 >3,000 SF NO Permit • Required Permit Project Design ECOS provides clearance (NOT Clearance Testing roject Manager required) 1 Oversight Manifested Disposal at • Approved Landfill AcnrcTnc PRnTrCT Cm Large asbestos project: An asbestos project involving the removal, disturbance, enclosure, encapsulation, repair or handling of 160 square feet or more of ACM, or 260 linear feet or more of ACM. Small asbestos project: An asbestos project involving the removal, encapsulation,enclosure, repair, disturbance or any handling of more than 10 and less than 160 square feet of ACM or more than 25 and less than 260 linear feet of ACM. Minor asbestos project: An asbestos project involving the removal, disturbance, repair, encapsulation, enclosure or handling of 10 square feet or less of ACM or 25 linear feet or less of ACM. GWS Office: (970)945-4407• Aspen Office: (970)925-3267 RECEIVED 6690 Hwy 82,Glenwood Springs,CO 81601. 401 Aspen Airport Business Center, Aspen,CO U /0 7/2 018 Email:info@ecosenvironmental.com• www.ecosenvironmental.com ASPEN BUILDING DEPARTMENT ecos ASBESTOS REMOVAL CATEGORIES Environmental Disaster Restoration,Inc. Category I Non-Friable ACM: NESHAP classification -Asbestos-containing packings, gaskets, resilient floor covering, and asphalt roofing products,containing more than one percent(1%) asbestos, that when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure. Category II Non-Friable ACM:NESHAP classification - Any material, excluding Category I Non-Friable ACM, containing more than one percent (1%) asbestos that,when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure. Class I Asbestos Work: OSHA term meaning activities involving the abatement of Thermal Systems Insulation (TSI), and surfacing ACM and PACM. Class II Asbestos Work: OSHA term meaning activities involving the abatement of ACM which is not TSI or surfacing material. This includes, but is not limited to, the removal of asbestos-containing wallboard, floor tile and sheeting, roofing and siding shingles, and construction mastics. Class III Asbestos Work: OSHA term meaning Repair and Maintenance operations, where no more than a minor quantity of ACM, including TSI and surfacing ACM and PACM, is likely to be disturbed. Class IV Asbestos Work: OSHA term meaning Maintenance and Custodial Activities during which employees contact but do not disturb ACM or PACM and activities to clean up non- ACM dust, waste and debris resulting from Class I, II and III activities. DEFINITIONS Abatement: Procedures to control fiber release from asbestos material. This includes removal, encapsulation, enclosure, repair, and disturbance of friable asbestos or any handling of asbestos material that may result in the release of asbestos fibers. Amosite: An Asbestiform mineral of the amphibole group containing approximately 50% silicon and 40% Iron (II) Oxide, and is made up of straight brittle fibers, light gray to pale brown in color. Amphibole: One of the two major groups of minerals from which the Asbestiform minerals are derived, distinguished by their chain-like crystal structure and chemical composition. Asbestos: A generic name given to a number of naturally occurring hydrated mineral silicates that possess a unique crystalline structure,are incombustible in air, and are separable into fibers. Asbestos includes the asbesti-form varieties of chrysotile (serpentine); crocidolite (Riebeckite); amosite (cummington-grunerite); anthophyllite;and actinolite. R �, GWS Office: (970) 945-4407• Aspen Office: (970)925-3267 ' `� ����� 6690 Hwy 82,Glenwood Springs,CO 81601 • 401 Aspen Airport Business Center,Aspen,CO Email: info@ecosenviroiunental.com • www.ecosenvironmental.com � /1611,7 2 018 ASPEN BUILDING DEPARTMENT ecos Environmental Disaster Restoration,Inc. Asbestos Project: Work undertaken by a contractor which at any time involves any aspect of the removal, encapsulation, enclosure or disturbance of friable asbestos, or any handling of asbestos material that may result in the release of asbestos fiber, except work in an owner- occupied single family dwelling performed by the owner of such dwelling. An asbestos project shall include the planning, design, monitoring, inspection, and air sampling of abatement work, as well as the supervising of such activities. Building Owner: The person in whom legal title to the premises is vested unless the premises are held in land trust, in which instance building owner means the person in whom beneficial title is vested. Electron Microscopy: A method of asbestos sample analysis which utilizes an electron beam to differentiate between fibers. Emergency: An unexpected, unanticipated or unforeseen occurrence, including but not limited to, a steam, chemical, gas or water line rupture, a boiler failure, or a building collapse, which poses (a) an imminent danger to the health and safety of the public, the response to which will constitute an asbestos project; or (b) an asbestos-related risk to the health and safety of the public from exposure to asbestos fibers. Friable Asbestos: Any materials that contain more than 1% asbestos and can be crumbled, pulverized, or reduced to powder by hand pressure. HEPA Filter Vacuum Equipment: Vacuuming equipment with a high efficiency particulate air filtration system. This filter is capable of trapping and retaining 99.97 percent of asbestos fibers greater than 0.3 microns equivalent aerodynamic diameter. Homogenous: Evenly mixed and similar in appearance and texture throughout. NESHAP: National Emission Standard for Hazardous Air Pollutants OSHA: Occupational Safety and Health Administration Operations and Management Plan (OMP): Specific procedures and practices developed for the interim control of asbestos-containing materials in buildings until it is removed. Polarized Light Microscopy (PLM): An optical microscopic technique used to distinguish between different types of asbestos fibers by their shape and unique optical properties. Repair: Corrective action using required work practices to control fiber release from damaged asbestos material. TSI: Thermal Systems Insulation GWS Office: (970)945-4407• Aspen Office: (970) 925-3267 RECEIVED 6690 Hwy 82,Glenwood Springs,CO 81601 • 401 Aspen Airport Business Center,Aspen,CO ay:Ls 7/2 018 rn Email: info@ecosenvironmental.com • www.ecosenvironental.com ay ASPEN BUILDING DEPARTMENT e Os LAB DATA linvironmentaI Disaster Restoration,Inc. Non Sample Suspect Material Detect Detect Percentage Friability Condition Al Tape,compound, X 0% Yes Good texture, drywall Tape, compound, A2 texture, drywall, X 0% Yes Good wood Texture, A3 compound, tape, X 0% Yes Good drywall Texture, A4 compound, tape, X 0% Yes Good drywall A5Tape, texture, X 0% Yes Good compound, drywall A6 Tape, texture, X 0% Yes Good compound, drywall A7 Texture, drywall X 0% Yes Good A8 Tape,compound, X 0% Yes Good texture, drywall A9 Texture, tape, X 0% Yes Good compound, drywall B1 Tape, wallpaper, X 0% Yes Good compound, drywall B2 Wallpaper, drywall X 0% Yes Good Mastic, drywall, B3 wallpaper, X 0% Yes Good compound Cl Drywall, texture X 0% Yes Good Texture, ° C2 compound, drywall X 0/° Yes Good C3 Texture, tape, X 0% Yes Good compound, drywall INVENTORY Homogenous Material Description A:Textured drywall Knock-down textured drywall throughout master bedroom, bedroom 2 closet, laundry,kitchen, living room, hallway bathroom,weight room, back room, coat room B: Textured drywall Wallpapered drywall in master bathroom C: Textured drywall Orange peel textured drywall upstairs bathroom RECEIVED GWS Office: (970)945 4407• Aspen Office: (970)925-3267 6690 Hwy 82,Glenwood Springs,CO 81601 • 401 Aspen Airport Business Center,Aspen,CO U O 7/2 018 Email: info@ecosenvironmental.com•www.ecosenvironmental.com ASPEN BUILDING DEPARTMENT e o s CONCLUSIONS: Environmental Disaster Restoration,Inc. Visual inspection was completed of the building materials that will be affected during the planned interior renovation plans. Fifteen samples were collected and sent to Aerobiology Laboratories in Golden, CO for analysis using Polarized Light Microscopy (PLM). All samples were non-detect for asbestos. GWS Office: (970)945-4407■ Aspen Office: (970)925-3267 RECEIVED 6690 Hwy 82,Glenwood Springs,CO 81601• 401 Aspen Airport Business Center,Aspen,CO al V 7/2 018 Email: info@ecosenvironmental.com •www.ecosenvironmental.com ASPEN BUILDING DEPARTMENT ecos CERTIFICATIONS Environmental • Disaster Restoration,Inc. r� ' I ti •jajy "' Colorado Department of Public Health and I-nirunmcnt ASBESTOS CERTIFICATION* this certifies Mat Brian Guzman Certification No.:21876 has met the requirements of25-7-507.C.R.S.ant air Quality Control (1>mtnition Regt.Iation No.N.Par.It.and is heivhy ecrti:ied a5 the sate eui('olorndo in the follow my d,,cipi,ae• Building Inspector* Issued: January 26. ZIl1' hapires, January 26. 2018 • 'rA.,.rnJWU.n OW.. .a.r... w a.n•. IS, •'I- ! J A-xm..e .roe nn..our... �•- n.Atem.rTMelJVaI,..A.v. OD�e;.rru.wr .`a A. I bide*-' \t� Colorado Department i of Public Health and Emironmcnt 0' _ ASBESTOS CONSULTING FIRM [his certifies that . .1 Ecos Environmental and Disaster Restoration, Inc] iRegistration No.:ACF-14480 has met the registration requirements of 25-7-507.C.R.S.and the Air Quality Control Commission.Regulation Nn.R.Part li.and is beret))authurized to perform asbestos cua ulting Oit e`f<- r activities as required under Regulation No 3, Part Ii, in the :talc of Colorado .` . -; issued: September 09,2016 Lixpires: September 09.2017 ?; ���, .....�r sea. - - — — RECEIVED .. , . • - _ r. .4 03/07/2018 ASPEN BUILDING DEPARTMENT e Os FINAL NOTES Lnvironmental Disaster Restoration,Inc. This report represents the opinion of the reporting asbestos inspector at the time of the asbestos assessment survey. If you have any further questions, or if additional information is needed please do not hesitate to call. Sincerely, Brian Guzman Colorado State EPA Asbestos Inspector #21876 ECOS Environmental & Disaster Restoration, Inc. (970) 945-4407 GWS Office: (970)945-4407■ Aspen Office: (970)925-3267 RECEIVED 6690 Hwy 82,Glenwood Springs,CO 81601• 401 Aspen Airport Business Center,Aspen,CO g1 1/10 7/2 018 Email: info@ecosenvironmental.com •www.ecosenvironmental.com ASPEN BUILDING DEPARTMENT Lair= 1 of z NIt........._ AERobiology.6 I.AbORATORy wil Page i . • .„ ... „. . ASSOCIATES, "'"` INCORPORATED .".4;:t,-5,.W1- .,•!--,,-. "'I-S.,' ,. Expertise Since 1997 iciows 0 I g li-%,. ..A tiViAP „,,A8 (, (col - . .: ....f: u.8102417 PA) ' '.j',:il,',11,4 INVIAP Lab Coda X0860 0(COI 'Apeman 4104 :A:*01$60rgii)0100t;.:'::1 ECOS Environmental&Disaster Restoration Az Co.GA,vA.NJ IMASt 0,4,2°303.1,1044 SAIIII210229(AZ) Field contact Brian Guzman '.::::::.....'44'•-:: ••-.:B0q1.441-.:.:,:..' . . . . - .. - *.:., ... .. .. ... . . .. Reporting Ralinqukhed Bin: 6690 Hwy 82 Glenwood Springs lwd;_va,;:_ 9-/5-)7 Address Billing Same Sampler Andersen ampleAlre Caw Address Type SAS AeroTrap Sioeulture....,:, Phone/Fax 970-618-3716 7!..I.5r'..-1!:..,ilititPE I_ - Piti':,..)., Reporting prpjectlfarpitrY.A'' / 7.. -.- 6--o'•O•57' ''4:r'. ' .'...* ...I....'.•"•''''' BGuzman@ecosenvironmental.com Email(s) RoutineO• 24 HbitiCiiiiiiiii•Da •• 4:14i0 :'i.'::.'1.....2 ' '1'2.:•'.' ‘PO.;:•:[:1':' DWI , SAMPLING LOCATION ZIP CODE CC Info: Sample No. Test Code Sample Location Total Volume/Area 1C-1`tOe i4tOWlet 'Pit f"-rig" ,de- -kt (f.-A 1 A i 3002 -re,frotzt- 1-1-eif VI -SV.Pec°04 Ce_.)5-eT".. • 2 •;.::::',.',.:. .;::.. ...•..A''.Z,.•.;;;:-:...... .:,.........-3.;9••••,:°,2•:':!.''.::! • - ' . - / i ',..;:':'.::::'•;:.,..:., ...- '1)144(4 6*:;•-. ::--•••••.6(46:;''' ',ert . I:::''S.:''...... l..1:::: ''::::'::'::.•••:',.•';':-:,',...• : . 3, A 3 3002 l Acivialtt-F1 . - .. - ' - ..': ''*-.-:-%•.:',;',''''. n...r.::. •••••:'..N.....'...., :...: .•„..::. •:,..:',..;,!- './.:'::•.'f'.:"...:.•••:::.:.':••••••'.'.....'•!;'!.' 4 .:. .. '_ tl: 1:.... . .... PP2 :•::•:::':•:::•.;.:. . •-. .. . ....-.K. .c:.1,1,ri ...:.•. •...;:;.,:.:.. .'. ..'.:..•.,.:.,-,..:. 5 A s 3002 (AV VAv. ctir...5/ et-1u j,....dtAk.6.e.0 ki . . lnn#3.,..... . - :.....,:„.„ , .„,.:,. . . 0 ?..".;!..,::..:•...::: :-.......•••,.. ,-!`'YA.• ViA TA 460t1,17141kei 7 AT 3002 Viet 5( 1.. IL 0c,v". Ca' .,it tAo" .:.'i...,•:'.:::':::A4 .::5.•. —3002 - - - k--3ise:.v.....- - , di.. . ......:,0,.. .. 8 ,,.'1.,...,,... .:*4:4!•.. ..• . 'T ••....' ,e4 krif , . - • 9 A q 3002 i e 0(1,7c —tC7r,vi" VviCAt A \-eUt 5.'' :'.1 ... '-''' . . ''''::','''":•::..' .1V%.•A-F'...•+e...*`•.'....c.-1'.:':- ., . ' .!''.:'.....--:-., 10 :.".:•:.. ' ' .. ' .Z -I '. 3002.. ... -1124'itM''"'''-': - kik'i- 6410e:X.''''i'ACii:i.Wait iii ''',''''''''''.-.• '.1. il 13 2. 300212 . ,..:,..,... . 3002:•:.c.,, .,.... '-:: : :. ::":-:. ,•,-,....,":,.-2,:?..:' , ,, -:,..• . - - '. ' -;,-:. :.•::-:. 0 1 145 A-(25 V .i"(/ A/let 7-*• 5 30N 134--rtheicoaA% ‘,/7W ‘/1-4 -ek7 P 13 1054 Direct,Non-viable Spore Trap 1015 Culture-WATER Legionelle 1051 "Direct,Qualitative-Swab/Tape 1017 Culture-SWAB Leglonelta 1050 Dirycj,qualltailve-12fulli , 1010 WATER-Potable-E.colt/total conforms 1005 AIR Culture-Bacterial Count w/ID's 1 12 SWAB-E.coil/total colfforms • 1030 AR Culture-Fungal Count w/Ib's 1028 Sewage Screen(E.coli/Enterococcusifecal conforms) 1005 SWAB Culture-Bacterial Count w/ID's 2056 HeterotLophic Plate Count 1031 SWAB Culture-Fungal Count w/ID's 3001 =RESTOS-Point count 1008 BULK Culture-Bacterial Count w/ID's 3002 ASBESTOS-iiLM-Analysis 1033 BULK Culture-Fungal Count w/ID's 3003 ASBBTOS-Particle characterization 1007 WATER Culture-Bacterial Count w/ID's 3004 ASBESTOS-PCM Analysis ' .. 7184 North Pork Drive.Pennsauken.NJ 08109-(856)488-1177 Fax(856)488-0005-email:infotapurearthiab.eorn 2400 Herodian Way.Suite 190.Smyrna,GA 30080-(WM 020-9313 Fax(770)947-2938-email ATLOaerobiology.nel 780 Shade Street Suite 104,Golden,CO 80401-(886)820-9348 Fax(303)232.0283-mai:denvertgoemblology.not 43760 Trade canter Place.Suite 100.Dulles,VA 20166-(877)e48-915e Fax(877)598-0946-email Infoiteembiology nel RECEIVED • 15001 Springdale&met Suite 111.Huntington Beads.CA 92649-(714)885-8401-(886)895-8132-eau&socalgatembloiogy.net 2228 West Northern Avenue:Suite B111),Phoenix.AZ 85021-(858)738-561D Fox(602)441-2818-email:phooniNatteroblology net 0S71°/2o3.8 ASPEN BUILDING DEPARTMENT 2- Z... Lab Um lighei‘_ AE Page ofRObiOlOgyA tAbORATORy 77<, ,, :3 tlr, ASSOCIATES, INICORi'ORATED Expertise Since 1997 ri 00&1 g- ,.... INVIAp —"'---:"'" '.1 1A111119258.1(CO) [ , ,..._,,,..21 liViAP lab Coal 20011604(C01 1,8 imos3 e ho .4#40i.000 0 i Client 1 EGOS Environmental&Disaster Restoration 1 Az.Co,GA VA.NJ =t="5= "11821°125 4'23 Field Contact Brian Guzman ',::.:.'i:i ...;'.'.‘.,.., ,•:',.'...*::OP9.14.1*1"7".. 00•:., !..1q4.••).-47,.•:. Reporting Relinquished By@c: W11,i,,.' 6890 Hwy 82 Glenwood Springs 1111 .11e:-4 Omer Address TYPO bAS_ Aero I nip BloCulture Phone/Fax\970-618-3716 7•2?1r!'ALI- ra-L o - PHI L . • -.:::'... Email' BGuzman@ecosenvironmentaI.com(sb. 771.7!..1,1-ne'. . ..=7-. I n-I- -— — ,4 T .' Actium() P..1Fiow #1M!P9.,: ;,..r.1 ..;• , d SAMPLING LOCATION ZIP CODE CC Wet Sample No. Test Code Sample Location Total Volume/Area I V PSTA r'a 5 i",?tt--T tf-a-C-3 3002 Ix A.7.tg et, • 3002 ..1.:1002... - 3002 : ". :USE •ONL '...... : •• ' - -. .. :. . 3002 ; ' ,..:`'.,.;,;Etej......;.., ,... 7.:i .. .1i..:•:. .. -..... . . . 3002 .410• -.--,-...............-....„„..,.,,,_„„.• • 1:i3002 . - .. ,... . . 3002 4Notes: CNI,) v ic. :....::,:!:::".:;:.:::::::.:...i::V.,... .. .....i....-.E.....:..'..:..1:-: .. iiiii.......,... .: .. .,.:-.;.r,i:-.4 ., : : . :.....‘;::::1-:...i......:....;...:''' - ' :••:::::.':',... i.'..'.'1, '3::::::':::: :::.....'....,.... ......,...: '•:: '. '. . : 1 3002 i''' -iiii?` / .. fr. 3002 D':::::':.••,:•i•••:1.. :!;,::';.?:':".....:C:.',;.•;% ;'-'.,',.. '.-, ' ' • '.'. • • .:'.......,..; :.:::::,...:...,.:',.[..::':!...i.:;':-••:::.W;•!... 1 3002 ..3002;..i 1054 -Direct,Non-viable Spore Trap 1015 Culture-WATER Legionella 1051 Direct,Qualitative-Swab/Tape 1017 —Culture-SWAB Legionella 1050 piLecl qualitative-Bulk 1010 WATER-Potable-E.coll/total conforms 1005 AIR Culture-Bacterial Count w/ID's 1012 SWAB-E.coU/total conforms 1030 AIR Culture-Fungal Count w/113's _ 1028 Sewage Screen(E.coll/Enterococcus/fecal collformis) 10Uti SWAB Culture-Bacterial Count w/ID's . 313 HeterotrophIc Plate Count 1031 SWAB Culture-Fungal Count w/ID's 1 XSBESTOS-Point count 1008 BULK Culture-Bacterial Count w/ID's 3002 'ASBESTOS-PLM Analysis 1033 BULK Culture-Fungal Count w/1D's 3003 ASBESTOS-Particle characterization 1007 WATER Culture-Bacterial Count wilD's 3004 ASBESTOS-PCM Analysis 7184 North Park Drive,Pennsauken,NJ 08109-(656)488-1177 Fax(058)468-0005-email:infoOpuroarthlab.corn 2400 Herodlan Way,Suite 190,Smyrna,GA 30080-(888)6204313 Fax(770)947-2938-ernaN:ATL@aarobiology.net 780 Simms Street Suite 104,Golden,CO 80401-(866)620-9343 Fax(303)232-0283-email:deriver@aerobiology.not 43760 Trade Center Place,Suite 100,Dulles,VA 20166-(877)648-0150 Fax 077)598-0946-email:info(goorobiology.net RECEIVED.06,Springdale Street.Suite 111.Huntington Beach,CA 92649-(714)396-6401-(666)895-8132-malt soceitteerobiology.net 2228 Weal Northern Avenue,suite 8110,Phoonbc,AZ 85021-(555)7336619 Fax(602)441-2818-omit phrianixtgaerotriology.nat 0 J7tr717 2018 ASPEN BUILDING DEPARTMENT 780 Simms Street Atldi AERObiolo LAbORATOR Suite 104 biology y Golden,CO,80401 ASSOCIATES,INCORPORATED 303.232.3746 —+'+'aeetK iira4razt66, Certificate of Analysis ^a-nemh:,tnay n.i Client Name ECOS Environmental n t1��® Date Collected 09/14/17 �� Street address 6690 HWY 82 Date Received: 09/15/17 City,State ZIP Glenwood Springs,CO 81601 Date Analyzed: 09/22/17 Attn: Brian Guzman NVLAP Lab Code 200860-0 Date Reported: 09/22/17 Client Project Name: A-17-0005-AT/Altfcld-Phil Project ID: 17030818 Job ID. Test Requested: 3002,Asbestos in Bulk Samples Method: Polarized Light Microscopy/Dispersion Staining(PLM),Method for the Determination of Asbestos in Bulk Building Materials.EPA-600/R-93/116,July 1993. Sample Identification Homo- Layer Non-Asbestos Non-Fibrous Matrix Physical Description of Sample/Layer geneous Percentage Det ected tected Asbestos Percentage Fiber Material Material Client Lab Sample Number MN) Percentage Percentage Composition 17030818-IA White Tape N 2% ND 99 I 17030818-1B White Joint Compound N 5% ND 100 C Al 17030818-IC White Texture w/Tan Paint N 5% ND 100 C 17030818-1D White/Tan Drywall N 88% ND 15 85 G 17030818-2A White Tape N 5% ND 99 1 17030818-2B White Joint Compound N 55'0 ND 100 C A2 17030818-2C White Texture w/Tan Paint N 55'0 ND 100 C 17030818-2D Tan Wood N 20% ND 100 17030818-2E White/Tan Drywall N 65% ND 15 85 G A3 17030818-3A White Texture w/Tan Paint N 25'0 ND 100 C A=Amosite Q=Quartz P=Perlite AC=Actinolite C=Carbonates B=Binder _ AN=Anthophyllite G=Gypsum D=Diatoms ���/ CI DRY ChrysoRle M=Mica ,f''(/�++iKd1L���,�e. �Ztt-- `-y% CR=Crocidolite T=Tar TR=Tremolite NTR=Non-Asbestiform TR Shannon Whitmore Talena Oliver Trace=Less Than 1% NAC=Non-Asbestiform AC Laboratory Analyst Asbestos Laboratory Supervisor ND=None Detected Page 1 of 7 780 Simms Street, Suite 104,Golden,CO,80401,303.232.3746 IE C E ei VE D 03/07/2018 ASPEN BUILDING DEPARTMENT iidkiSii . 780 Simms Sired AERObic �0 LAbORATOR Suite 10 Gy y Golden,CO,80401 ASSOCIATES,INCORPORATED 303.232.3746 ei as ggsessfts4 Certificate of Analysis www••mhloIngy n•t Client Name ECOS Environmental ((((����0 Date Collected: 09/14/17 Street address 6690 HWY 82 aVdQg Date Received: 09/15/17 City,State ZIP Glenwood Springs,CO 81601 Date Analyzed: 09/22/17 Attn: Brian Guzman NVLAP Lab Code 200860-0 Date Reported: 09/22/17 Client Project Name: A-1 7-0005-AT!Altfeld-Phil Project ID: 17030818 Job ID: Test Requested: 3002,Asbestos in Bulk Samples Method: Polarized Light Microscopy/Dispersion Staining(PLM),Method for the Determination of Asbestos in Bulk Building Materials.EPA-600/R-93/116,July 1993. Sample Identification HOmo- Layer Non-Asbestos Non-Fibrous Matrix Physical Description of Sample/Layer geneous Percentage Asbestos Detected Asbestos Percentage Fiber Material Material Client Lab Sample Number lY/M Percentage Percentage Composition 17030818-3B White Joint Compound N 5% ND 100 C A3 17030818-3C White Tape N 5% ND 99 1 17030818-3D White/Tan Drywall N 88% NI) 15 85 G 17030818-4A White Texture w/Tan Paint N 2% ND 100 C 17030818-4B White Joint Compound N 35'0 ND 100 C A4 17030818-4C White Tape N 55'0 ND 99 1 17030818-4D White/Tan Drywall N 90% ND 15 85 G 17030818-5A White Tape N 3% ND 99 1 A5 17030818-5B White Texture w/Tan Paint N 55'0 NI) 100 C 17030818-5C White Joint Compound N 55 o ND 100 C A=Amosite Q=Quartz P=Perlite AC=Actinolite C=Carbonates B=Binder _ AN=Anthophyllite G=Gypsum D=Diatoms 9 �7 jaaee-Lt, CHRYhrysotileM=Mica �II.(A�'"�`L`'[%1��L �/��-- CR=Croctdolite T=Tar TR=Tremolite NTR=Non-Asbestifonn TR Shannon Whitmore Talena Oliver Trace=Less Than 1% NAC=Non-Asbestiform AC Laboratory Analyst Asbestos Laboratory Supervisor ND=None Detected Page 2 of 7 780 Simms Street,Suite 104,Golden,CO,80401 RE C E I\1E 03/07/2018 ASPEN BUILDING DEPARTMENT A2ili‘I&kii . 780 Simms Street AERObiotO LAbORATOR Suite 104 GY Y Golden,CO,80401 ASSOCIATES,INCORPORATED 303.232.3746 Certificate of Analysis wt.'',a•mhintngy net Client Name ECOS Environmental addaf0 Date Collected 09/14/17 Street address 6690 11WY 82 Date Received: 09/15/17 City,State ZIP Glenwood Springs,CO 81601 Date Analyzed: 09/22/17 Attn: Brian Guinan NVLAP Lab Code 200860-0 Date Reported 09/22/17 Client Project Name: A-17-0005-AT/Altfeld-Phil Project ID: 17030818 Job ID: Test Requested: 3002,Asbestos in Bulk Samples Method: Polarized Light Microscopy/Dispersion Staining(PLM),Method for the Determination of Asbestos in Bulk Building Materials.EPA-600/R-93/116,July 1993. Sample Identification Homo- Layer Non-Asbestos Non-Fibrous Matrix Physical Description of Sample/Layer B us percentage Asbestos Detected Asbestos Percentage Fiber Material Material Client Lab Sample Number (Y/N) Percentage Percentage Composition A5 17030818-5C White/Tan Drywall N 87% ND 15 85 G I7030818-6A White Tape N 5% ND 99 I 170308I8-6B White Texture w/fan Paint N 5% ND 100 C A6 17030818-6C White Joint Compound N 5% ND 100 C 17030818-6D White/Tan Drywall N 85% ND 15 85 G 17030818-7A White Texture w/Tan Paint N 5% ND 100 C A7 17030818-7B White/Tan Drywall N 95% ND 15 85 G 17030818-8A White Tape N 20% ND 99 1 A8 17030818-8B White Joint Compound N 25% ND 100 C 17030818-8C White Texture w/Tan Paint N 25% ND 100 C A=Amosite Q=Quartz P=Perlite AC=Actinolite C=Carbonates B=Binder AN=Anthophyllite G=Gypsum D=Diatoms j/ d� CHRY�h i M—Mica Jl/1,�ilvyt � +�ZR— ` r���' CR=Crocidolite T=Tar TR=Tremolite NTR=Non-Asbestiform TR Shannon Whitmore Talena Oliver Trace=Less Than 1% NAC Non-Asbestiform AC Laboratory Analyst Asbestos Laboratory Supervisor ND=None Detected Page 3 of 7 780 Simms Street,Suite 104,Golden,CO,80401 RECEIVED 03/07/2018 ASPEN BUILDING DEPARTMENT 780 Simms Street AEROb1OLO LAbORATOR Suite 104 GY Y Golden,co,soao I ASSOCIATES,INCORPORATED 303.232.3746 +.z./ Certificate of Analysis .vwwe semhinlney nel Client Name ECOS Environmental ro Date Collected: 09/14/17 Street address 6690 HWY 82 Date Received: 09/15/17 City,State ZIP Glenwood Springs,CO 81601 Date Analyzed: 09/22/17 Attn: Brian Guzman NVLAP tub Code 200860-0 Date Reported: 09/22/17 Client Project Name: A-I 7-0005-AT/Altfcld-Phil Project ID: 17030818 Job ID: Test Requested: 3002,Asbestos in Bulk Samples Method: Polarized Light Microscopy/Dispersion Staining(PLM),Method for the Determination of Asbestos in Bulk Building Materials.EPA-600/R-93/I 16,July 1993. Homo- Non-Asbestos Non-Fibrous Matrix Sample Identification ph cal Descri ion of Sam I Layer P e/Layer 8eneous Percentage Asbestos Detected Asbestos Percentage Fiber Material Material Client Lab Sample Number tY/N) Percentage Percentage Composition A8 17030818-8D White/Tan Drywall N 30% ND 15 85 G I7030818-9A White Texture w/Tan Paint N 3% ND 100 C 17030818-9B White Tape N 7% ND 99 1 A9 17030818-9C White Joint Compound N 10% ND 100 C I7030818-9D White/Tan Drywall N 80% ND 15 85 G 17030818-10A White Tape N 5% ND 99 1 17030818-10B Tan Wallpaper N 10% ND 95 5 B B I 17030818-I0C White Compound w/White Paint N 10% ND 100 C,G 17030818-1OD White Joint Compound N 10% ND 100 C 17030818-10E White/Tan Drywall N 65% ND 15 85 G A=Amosite Q=Quartz P=Perlite AC=Actinolite C=Carbonates B=Binder AN=Anthophyllite G=Gypsum D=Diatoms CHRY=Chrysotile NI=Mica �� � aeAjt CR=Crocidolite T=Tar TR=Tremolite NTR=Non-Asbestiform TR Shannon Whitmore Talena Oliver Trace=Less Than 1% NAC=Non-Asbestiform AC Laboratory Analyst Asbestos Laboratory Supervisor ND=None Detected Page 4 of 7 780 Simms Street,Suite 104,Golden,CO,80401 RECEIVED 03/07/2018 ASPEN BUILDING DEPARTMENT AalligliLlifb 780 Simms Street AEIZObiol0 LAbORATOR Suite 104 ciY Y Golden,CO,80401 ASSOCIATES,INCORPORATED 303.232.3746 ZWetioeset .ra,.f Certificate of Analysis www umhiranuy nei Client Name ECOS Environmental IKW�a@® Date Collected: 09/14/17 Street address 6690 HWY 82 Date Received: 09/15/17 City,State ZIP Glenwood Springs,CO 81601 Date Analyzed: 09/22/17 Attn: Brian Guzman NVL.AP tab Code 200860-0 Date Reported: 09/22/17 Client Project Name: A-I 7-0005-AT/Altfeld-Phil Project ID: 17030818 Job ID: Test Requested: 3002,Asbestos in Bulk Samples Method: Polarized Light Microscopy/Dispersion Staining(PLM),Method for the Determination of Asbestos in Bulk Building Materials.EPA-600/R-93/116,July 1993. Sample Identification Homo- dyer Non-Asbestos Non-Fibrous Matrix Physical Description of Sample/Layer geneous Percentage Asbestos Detected Asbestos Percentage Fiber Material Material Client Lab Sample Number (Y/N) Percentage Percentage Composition 17030818-I lA Tan Wallpaper N 25% ND 95 5 B B2 17030818-I 1B White/Tan Drywall w/White Paint N 75% ND 15 85 G 17030818-12A Clear Mastic N l0% ND 100 B 17030818-12B White/Tan Drywall N 20% ND 15 85 G B3 17030818-12C Tan Wallpaper N 30% ND 95 5 B 17030818-12D White Compound w/White Paint N 40% ND 100 C 17030818-13A White Texture w/Green Paint N 2% ND 100 C CI 17030818-13B White/Tan Drywall N 98% ND 15 85 G 17030818-14A White Texture w/Green Paint N I% ND 100 C C2 17030818-14B White Compound N 4% ND 100 C,G A=Amosite Q=Quartz P=Perlite AC=Actinolite C=Carbonates B=Binder AN=Anthophyllite G=Gypsum D=Diatoms CHR Crocidolile M�-Mica am CR=Crocidolite T=Tar TR=Tremolite NTR=Non-Asbestiform TR Shannon Whitmore Talena Oliver Trace=Less Than 1% NAC Non-Asbestiform AC Laboratory Analyst Asbestos Laboratory Supervisor ND=None Detected Page 5 of 7 780 Simms Sheet,Suite 104,Golden,CO,80401 RECEIVED 03/07/2018 ASPEN BUILDING DEPARTMENT ..4iiiSkt . 780 Simms Street 4 AERObiaic LAbORATOR Suite401 �-iY Y Golden,CO,80401 ASSOCIATES,INCORPORATED 303.232.3746 G1aeees Certificate of Analysis www nembnegy no i Client Name ECOS Environmental `vlaQ�19 Date Collected: 09/14/17 �l Street address 6690 HWY 82 r1 Date Received: 09/15/17 City,State ZIP Glenwood Springs,CO 81601 Date Analyzed: 09/22/17 Attn: Brian Guzman NVLAP Lab Code 200860-0 Date Reported: 09/22/17 Client Project Name: A-I 7-0005-AT/Altfeld-Phil Project ID: 17030818 Job ID: Ten Requested: 3002,Asbestos in Bulk Samples Method: Polarized Light Microscopy/Dispersion Staining(PLM),Method for the Determination of Asbestos in Bulk Building Materials.EPA-600/R-93/I 16,July 1993. Homo- Non-Asbestos Non-Fibrous Matrix Sample Identification Layer Physical Description of Sample/Layer Sew Percentage Asbestos Detected Asbestos Percentage Fiber Material Material Client Lab Sample Number (Y/N) Percentage Percentage Composition 17030818-14C White Compound w/Gray Paint N 30% 5% 100 C C2 17030818-I4D Tan Drywall N 65% ND 15 85 G 17030818-15A White Texture w/Green Paint N 1% ND 100 C 17030818-15B White Tape N 5% ND 99 1 C3 17030818-15C White Joint Compound N 5% ND 100 C 17030818-15D White Compound w/Gray Paint N 24% ND 100 C,G 17030818-I5E White/Tan Drywall N 65% ND 15 85 G A=Amosite Q=Quartz P=Perlite AC=Actinolite C=Carbonates B=Binder Li AN=Anthophyllite G=Gypsum D=Diatoms CHRY=Chrysotile M=Mica �'L�� CR=Crocidolite T=Tar TR=Tremolite NTR=Non-Asbestiform TR Shannon Whitmore Talena Oliver Trace=Less Than 1% NAC=Non-Asbestiform AC Laboratory Analyst Asbestos Laboratory Supervisor ND=None Detected /■ Page 6 or7 780 Simms Street,Suite 104,Golden,CO,80401 RECEIVED 03/07/2018 ASPEN BUILDING DEPARTMENT 780 Simms Street Suite 104 AERObiOLOgy LAbORATORy Golden,CO,80401 ASSOCIATES, INCORPORATED 303.232.3746 rr.a.Z. Certificate of Analysis www armhiningy_net ECOS I:nvironntcntal IKWUf� Date Collected: 09/14/17 6690 HWY 82 Date Received: 09/15/17 Glenwood Springs,CO 81601 Date Analyzed: 09/22/17 Brian Guzman NVLAP Lab Code 200860-0 Date Reported: 09/22/17 Client Project Name: A-17-0005-AT/Altfeld-Phil Project ID: 17030818 Job ID: General Notes • ND indicates no asbestos was detected;the method detection limit is 1%. • Trace or"<1"indicates asbestos was identified in the sample,but the concentration is less than 1%. • All regulated asbestos minerals(i.e.chrysotile,amosite,crocidolite,anthophyllite,tremolite,and actinolite)were sought in every layer of each sample,but only those asbestos minerals detected are listed.Amosite is the common name for the asbestiform variety of the minerals cummingtonite and grunerite. Crocidolite is the common name used for the asbestiform variety of the mineral riebeckite. • Tile,vinyl,foam,plastic,and fine powder samples may contain asbestos fibers of such small diameter(<0.25 microns in diameter)that these fibers cannot be detected by PLM. For such samples,more sensitive analytical methods(e.g.TEM,SEM,and XRD)are recommended if greater certainty about asbestos content is required. Semi-quantitative bulk TEM floor tile analysis is accepted under NESHAP regulations. • These results are submitted pursuant to Aerobiology Laboratory Associates,Inc.'s current terms and conditions of sale,including the company's standard warranty and limitation of liability provisions. No responsibility or liability is assumed for the manner in which the results are used or interpreted. • Unless notified in writing to return the samples covered by this report,Aerobiology Laboratory Associates,Inc.will store the samples for a minimum period of thirty(30)days before discarding. A shipping and handling charge will be assessed for the return of any samples. • Aerobiology does not guarantee the results of tape lifts,microvacs,wipe,and/or debris samples. Accurate analysis cannot be performed due to particle size,media used,and/or amount of material given. Analysis of these materials should be preformed by a TEM. A result of ND does not indicate that the sample area does not contain asbestos. It means the analyst could not identify asbestos in the specific sample for the reasons listed above. Notes Required by NVLAP • This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP,NIST,or any agency of the Federal Government. • This test report relates only to the items tested or calibrated. • This report is not valid unless it bears the name of a NVLAP-approved signatory. • Any reproduction of this document must include the entire document in order for the report to be valid. Page 7 of7 RECEIVED 780 Simms Street, Suite 104,Golden,CO,80401,303.232.3746 03/07/2018 ASPEN BUILDING DEPARTMENT