HomeMy WebLinkAboutFile Documents.993 Moore Dr.0322.2017 (10).ARBK ACTIVE ENERGIES SOLAR.. Solar Installation Information Vendor: Active Energies Solar LLC PO Box 7627 Avon, CO 81620 (970-306-4233/info@activeenergies.com) Site: Harland Leeds Residence 993 Moore Drive Aspen, CO 81611 System Layout: Single Panel: 5.42ft tall X 3.25ft wide Panel Arrangement: 12 columns of 7&2 columns of 3+2 panels,oriented in the portrait position,mounted flush(rail-less)on the east facing garage roof,and 24 panels with RM5 ballast mounted in landscape on central flat roof,and 18 panels with RM5 ballast mounted in landscape on north flat roof 4 _1iiijTç;t _4TiT .f• I\: I I I � I 11 l-al M)I I O , 11111 External I Disconnect / & PV Meter ma: 111111 Inverters & / Combo panel I � MMININ- (located outsideSW corner of ' HCE electric meter at SW corner of Garage with Production meter and disconnect co-located. Minimum Designed Temperature: -40°F Maximum Ambient Design Temperature: 140°F All AC wiring to be completed by project Colorado licensed master electrician All DC wiring to be overseen by NABCEP certified installer Calculations Page 1 of 4 12/16/2019 P.O.Box 7627,Avon,CO 81620 P: 970.306.4233 F: 866.403.3485 www.activeenergies.com ACTIVE ENERGIES SOLAR.. 48.96kW System Size (STC) • 136 Solaria PowerXT all black solar panels @ 360 watts • 136 SolarEdge P370 Optimizers • 4 SolarEdge SE11400H-US inverters o Inverter 1 (4 strings of 12/12/9/9: 8-16 allowable) o Inverter 2 (3 strings of 10/10/10: 8-16 allowable) o Inverter 3 (3 strings of 10/10/10: 8-16 allowable) o Inverter 4 (3 strings of 12/11/11: 8-16 allowable) • Fixed array tilt angle: 7.18°, 5° • Array azimuth: 90°, 180°(where 180°is south) • Estimated annual power production: 65,429kWh Maximum PV System Voltage: 690.7 Voc =47.7V/module 47.7V x 1 module=47.7V No Temperature correction factor 690.7(A) Maximum PV Source Circuit(String) Current: 690.8 (A)(1) Ise =9.56A 9.56A x 1.25 = 11.95A Maximum PV Output Circuit(Array) Current: 690.8 (A)(2) SE11400H-US inverter limit 30.5A combined string Inverter Output Circuit Current: 690.8 (A)(3) 47.5A @ 240V for SE11400H-US inverter Page 2 of 4 12/16/2019 P.O.Box 7627,Avon,CO 81620 P: 970.306.4233 F: 866.403.3485 www.activeenergies.com A( arrI\ h: ENERGIES Conductor Sizing Pass Thru Box from Optimizers to Inverter (combined strings per inverter): SE11400H-US inverter limit 30.5A combined string 30A x 1.25 = 38.1A #8 THHN-2 Table 310.16 55A (902C column,see note 240.4(D)) Conduit fill adjustment Table 310.15 (B)(3)(a) No Conduit Fill Adjustment Inverter to Combiner panel: SE11400H-US inverter Nameplate maximum continuous Output Current: 47.5A @ 240V 47.5A x 125% = 59.4A 210.19 (A)(1) #6 THWN-2 Table 310.16 65A (75°C Column) 60A 2pole breaker in panel No temperature correction factor No conduit fill adjustment Combiner panel to PV Production Meter: 4x 60A breakers in combiner panel (1 per inverter) 1x 250A main Breaker Nameplate maximum continuous Output Current: 59.4A x 3 = 178.2A @ 240V CU 250kcmil Table 310.16 255A (75°C Column) No temperature correction factor No conduit fill adjustment Overcurrent Protection Device 250A two pole breaker Per Manufacturer Specification Conductors may be oversized for voltage drop Page 3 of 4 12/16/2019 P.O. Box 7627,Avon,CO 81620 P: 970.306.4233 F: 866.403.3485 www.activeenergies.com ACTIVE ENERGIES SOLAR.MC 4 Arrays Line Diagram 48 96kW Utility Interactive 136 PowerXT 360w Solar Panels SolarEdge 6E11400H-11S Inverter w/Integrated Photovoltaic System Disconnect 136 SolarEdge P370 DC Optimizers Harland Leeds Residence Max AC Output 475A@240V Modules: 136 x Solaria PowerXT 42/30/30/34 modules/optimizers per inverter With ARC Fault Protection Si Rapid Shutdown 360W 993 Moore Drive compliant-on SW exterior wall of Garage r Aspen, CO 81611 3inverte.ct"el Voc=47.7V 6#Fr PV Wire ■L "!- zs z� 33 Inv.1 condaaorein12/12/9/9 Optimizers: 136 SolarEdge P370 Free Air • Inverter 1(3 strings of 12112118:8-18 '100' allowable) 8/3 FMC w/G Inverter 2(3 strings of 10/10/10:8-18 1 2 3 12 34 35 36 42 ��..,a•w....ar. allowable) ... Inverter 3(3 strings of 10/10/10:8-18 allowable) Inverter (3 strings of 12/11/11:8-18 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ allowable) Inverters:4x SolarEdge 11400H-US 6#10 PV Wire /` 1#6G Bare Cu Array 2 11 12 13 ••• 20 21 22 23 ... 30 Operating Voltage:240V Conductors in _ 4 _.'•^^... Free Air 10/10/10 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ _ •___ Inv.2 Operating Current:30.5A — Max System Voltage:480V 8/3 FMC w/G u ,_,`,_, • Max Output Current: 15.1A 1 — 2 - 3 --- 10 NeWma.MM ------ Tilt Angle:7.18°,5° `LI---a--Er---Er Array Azimuth:90°, 180° , r 11 12 13 ••• 20 21 22 23 ... 30 n _a_M rsrei 6#10PV Wire -- 1#6G Bare Cu Array 3l ir 1 ❑ ❑ ❑ ❑ LED ❑ �J ,-~ Inv.3 Conde ors in 10/10/10 Notes: 8/3 FMC w/G -See Calculation Sheet for 1 2 3 10 — - — ,. . ... conductor sizing. -All conductors are copper unless otherwise noted. 13 14 15 ... 23 24 25 26 ... 34 ^ �_,...., -Inverter listed(UL-1741)to de- a 0PVWir Bare e Array 4 1 L Inv.4 energize upon loss of utility voltage Conductors in I ❑ ❑ ❑ El ❑ ❑ ❑ ❑ per NEC 705.40. Free Air 12/11/111 8/3FMCw/G ,. • -Inverter has integral ground-fault 1 2 3 12 protection per NEC 690.41 - — Combiner Panel " p co-�oCated w/ �- -240V 1 Phase combiner Panel 0' inverters rating of 250A(bus rating 250 amp CT Net meter, exterior, cir"' _ and 250A Main disconnect)to pedestal � °� Production -•• 250A main I""'"""^"i accommodate 4x 60A(PV)breakers .'''''; n breaker w/ EI1 I 1000A mein Meter within 250A Ell -1000A 240V 1 Phase Service breaker w/ 10'of net AC Disco adjacent buabar I M, , /� 1000A bulbar meter y, to net meter Ir��� Iraoa�� / 1 -Load Side Tap for Power sources 4x 60A from installations per 2017 NEC r breakers(1 for nrgrevamr snare coanrnr° , I TAP �•••. hinvener 705.12(B)(2)(2) •• Internal MSP O • (garage) _1 I 1\ /i PH.1 1 Ts,�� • — �Iw 'ir- 5' UISC:UNN,t_i U1)4 DC Grounding LT 1 1/4"PVC/EMT Electrode Conductor Net Meter 2"PVC/EMT 2"PVC/EMT 250A Fusible 2"PVC/EMT 8#6 THWN-2 solid bare#6 Cu,per 3x 250 kcmil CU 3x 250 kcmil CU disconnect 3x 250 kcmil CU 1#8 G THWN-2 NEC 250.66(C) On SW side of 1#4 G THWN-2 1#4 G THWN-2 1#4 G THWN-2 Garage Page 4 of 4 P.O.Box 7627,Avon,CO 81620 1 P: 970.306.4233 1 F: 866.403.3485 1 www.activeenergies.com