HomeMy WebLinkAboutFile Documents.1320 Mountain View Dr.0291.2018.ARBK 1320 Mountain View Dr_BuildingComments_2
1320 Mountain View Dr.ARCH.PERMIT SET.2019.05.pdf(2)
Page: [21]A-301 SECTIONS
File Name: 1320 Mountain View Dr.ARCH.PERMIT Include a for the slab edge
e SET.2019.05.pdf insulation. Slab-on-grade floors
" — Author: bonniem with a floor surface less than 12"
below grade must have
_ _ Subject: Slab edge insulation insulation extending downward
1 m Color: •
from the top of the slab on the
il*_� k „a -_ j outside or inside of the
- �y foundation wall.The insulation
must be extended for by any
'� """'"' combination of vertical
insulation, insulation extending
under the slab or insulation
extending out from the building.
See the details below for
examples. The R-19 insulation
called for in your RESCheck
must extend 4'. Alternately give
the slab an R value of'0'on the
RESCheck. (2015 IECC
402.2.10)
Page: [28]A-700 INSULATION SCHEDULE
File Name: 1320 Mountain View Dr.ARCH.PERMIT Correct instances where the
SET.2019.05.pdf listed insulation values differ
Author: bonniem from what is listed in the
Subject: PlanCheck RESCheck and shown in the
in • details:
- REScheck lists the basement
Tr
walls as R-38 insulated concrete
forms and the insulation
schedule lists below grade walls
as R-15 cavity insulation + R-6
continuous exterior insulation.
Detail 9 on A 501 for the crawl
space only shows the exterior
insulation. Correct for
consistency.
- RESCheck calls for R-19
insulation for the slab on grade,
where the insulation schedule
lists R-10.
rc-report.1320 Mountain View.2019.05.pdf(2)
Page: 1
,/"c„'"'".„•,P :rt„= cIf,-Le On the RESCheck,the cavity
CI File Name: rc-report.1320 Mountain View.2019.05.pdf insulation needs to be separated
Author: bonniem
Subject: PlanCheck out from the continuous
Color • insulation. Per your insulation
schedule, R-21 batt insulation
7 u===_=--- should be listed as cavity, and
R-6 outside the sheathing should
be listed as continuous.
Page: 1
File Name: rc-report.1320 Mountain View.2019.05.pdf Fill out owner and designer
Co iancempl Ce rtHkate Author: bonniem information on the REScheck,
Subject: PlanCheck and sign the signature line.
Color: ■
Solar ProposalPKG.Solaria.1320 Mountain View Dr.2019.05.pdf(1)
Page: 2 The renewable credit is based
File Name: Solar ProposalPKG.Solaria.1320 Mountain View on the lesser of the labeled
9.05.pdf
Author: bonniem
panel output power or the input
Author:
Subject: PlanCheck power of the inverter. Because
Color: • there are 2 X 6000 watt
aam:r; inverters, the capacity of the
• __-- system is limited to 12 kw which
~ = — is the REMP mitigation credit
= m that will be given based on this
proposal. (See Ordinance 40,
2011 Appendix RC Section 301)