HomeMy WebLinkAboutFile Documents.134 Maple Ln.0138.2019 (12).ARBK ***This approval does not exempt the project from other City of Aspen Land Use Code or Smuggler Park PD requirements
Residential Design Standards ,
‘4aa
Administrative Compliance Review Staff Checklist - Single Family and Duplex FA,PtN
Address: 134 Maple Lane
Parcel ID:273707490134
Zone District/PD:Smuggler Park PD Approved: Ben Digitally signed by
Ben Anderson
Representative:James Foerster Anderson Date: 2019.05.20
(Approved plans/elevations attached) 14:29:14 -06'00'
Email:james@raftinginaspen.com
Phone:james@raftinginaspen.com
Disclaimer: This application is only valid for the attached design.If any element of the design subject to Residential Design Standards changes prior to or during building permit review, the
applicant shall be required to apply for a new Administrative Compliance Review.
Standard Co Alternative Does N/A Sheet#(s)/Notes
1111
6. Compliance Comply
B.1.Articulation of Building Mass _____T
-
r Outside of Infill Area
(Non-flexible) ✓
B.2.Building Orientation Home is oriented to the pedestrian street along the west (front facade).
(Flexible) ✓ r Orientation is not changing in this remodel project
B.3.Build-to Requirementr V 30' (of a total 46') are within 5' from front yard setback approx. 65%
(Flexible)
B.4.OneStoryElement(Flexible) 6/ r Roof line is changing to some degree - but essentially remains a
one-story mass throughout.
C.1.Garage Access r Garage is accessed off Public ROW from Maple Lane - no alley or
(Non-flexible) ✓ private road
C.2.Garage Placement r Garage door not required to be setback 10' per Smuggler PD
(Non-flexible) ✓ agreement
C.3.Garage Dimensions Garage entrance is approximately 8' - far below maximum ll-E.w �IEIVED
(Flexible) ✓
08/29/2019
r:, 1 ,,t 2ASPEN
BUILDING DEPARTMENT
Ben eee°i eas•m •
Andersonmm Residential Design Standardsili
Approved: 29
Administrative Compliance Review Staff Checklist THE CITY OFASPEN
Disclaimer: This application is only valid for the attached design.If any element of the design subject to Residential Design Standards changes prior to or during building permit review, the
applicant shall be required to apply for a new Administrative Compliance Review.
Complianrillirlir Sheet#(s)/Notes
C.4.GarageDoorDesign Single garage door
(Flexible) V [
[
D.1.EntryConnection(Non flexible) V I r Location of Entry door is not changing on west facade facing the
pedestrian way
D.2.DoorHeight 1 Entry door is less than 8ft - no other street facing doors are greater than
(Flexible) ✓ 8'
D.3.EntryPorch Entry porch is at least 25 sq. ft. per Smuggler Park PD. It has a
(Flexible) V minimum depth of at least 4 feet.
E.1.Principle Window V
The principal window is at least 2'x4' per Smuggler Park PD
(Flexible)
E.2.WindoPlacement V
No windows span more than one-story
(Flexiblexible))
E.3.Nonorthogonal Window Limit ✓ Outside of Aspen Infill Area
(Flexible)
E.4.Lightwell/Stairwell Location ✓ No lightwells or stairwells are located on a street facing facade
(Flexible)
E.5.Materials All materials a carried forward on all sides of building - a combination of.
(Flexible) ✓ I [ wood and metal siding. icaY•.;..tli.y IED
08/29/2019
Pa<<c 2 of 2
ASPEN
BUILDING DEPARTMENT