Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.1250 Snowbunny Ln.0040.2018 (32).ARBK
4 Maly TL 'cy® „,... Roofing Products 0 Tt'cy® & jrchoGar TECHNICAL PRODUCT DATA SHEET A STEEP SLOPE - RESIDENTIAL - LAMINATE - SKU:272/273 TECHNICAL DETAILS WEIGHT/SQUARE EXPOSURE 275 lbs. 55/8" 124.7 kg 143 mm -N, SHINGLES/SQUARE GRANULE ADHESION FLEXOR' SBS POLYMER 64 0.35 g MODIFIED LAMINATED :_�. s 4 bundles/square Typical Results :r ., WIDTH Ye" LENGTH va" ARCHITECTURAL SHINGLES -a► 131/4" 40" - '• 337 mm 1.02 m SQUARES/PALLET PRODUCT USE 12 The 272 Legacy®shingle and 273 Legacy®featuring Scotchgard'"are laminated asphalt shingles fortified from OR/CA/OK with Flexor'""SBS polymer modified asphalt technology for extreme weather protection.They are to be used [TEST COMPLIANCE 1 whenever increased flexibility,architectural design,tensile strength,and tear-resistance in shingles is desired. The Legacy®line features the exclusive nailing accuracy-enhancing design of The Zone®.The larger nailing area ASTM ASTM of The Zone®dramatically improves correct fastener placement.The Legacy®Silverwood shingle is CRRC-listed D7158 D3462 and can be used to comply with CEC Title 24, Part 6 Cool Roof Requirements. Class H ASTM ASTM COMPOSITION &MATERIALS D3161 D3018 Legacy®is a mineral-surfaced, self-sealing, laminated architectural shingle with a Flexor"SBS polymer Class F Type I I modified asphalt coating and fire retardant fillers on a non-woven fiberglass mat.The Silverwood granule ASTM UL RATING color adds solar reflectivity. Legacy®featuring Scotchgard'M is surfaced with embedded, Scotchgard'"algae E108 2218 resistant granules. Class A Fire Rating Class 4 APPLICATION CSA ICC APPROVAL Shingles should be applied over a Malarkey underlayment or an approved,code-compliant substitute. A123.5 ESR-3150 Installation instructions are available on the shingle wrapper,at WWW.MALARKEYROOFING.COM, or by contacting your local Malarkey representative. Industry standards are found in NRCA manuals. Shingles • FBC APPROVAL should be attached to decking with approved fasteners, and Malarkey recommends the use of corrosion- #14809 resistant nails for this purpose. Staples are not allowed. LISTED PRECAUTION ETAI /� For best results, Malarkey recommends The Legacy®shingle line be protected from the weather and stored .. CRC`® in a cool, dry,well-ventilated area until applied. Do not double-stack pallets. Do not use on roofs where the Intertek rRATEcDT slope is less than 2:12(2" [51 mm] per 12" [305 mm]). For slopes 2:12 up to 4:12(4" [102 mm] per 12" Compliant with CEC [305 mm]), a double layer of underlayment is required.The Legacy®shingle line has a factory-applied self- Title 24, Part 6 sealing strip that activates in warm weather.When applied in cold weather or windy locations, hand-sealing is recommended but not required if sealant activates. On slopes greater than 21" (533 mm)per 12" (305 mm), Cool Roof Requirementst hand-sealing underneath and six nails are required. Contact Malarkey for further conditions and instructions. i.FEATURES&BENEFITS111 WARRANTY •Scotchgard' protection from 3M •Extreme weather protection Malarkey Roofing Products offers various warranties to meet specific requirements.The warranty packages •Superior granular embedment available for the Legacy®shingle line include a Limited Lifetime Warranty,a 110 mph(177 kph) Limited Wind •Flexor'"SBS polymer modified asphalt Warranty, and can be combined with other Malarkey products for a 130 mph(209 kph) Enhanced Wind •The Zone®nailing area Warranty. Legacy®featuring Scotchgard'M also carries a 20-year Algae Resistant Shingle warranty against •All-weather flexibility algae growth. Contact your roofing contractor, local distribution center,or Malarkey for full details. See below •Double rain seal protection for TECHNICAL ASSISTANCE contact information. •Limited Lifetime Shingle Warranty The Legacy®shingle line and other Malarkey products are available throughout North America and Pacific •Limited&Enhanced Wind Warranties Rim countries. f CRRC and California Energy Code Title 24, Visit WWW.MALARKEYROOFING.COM for additional product information and availability. Part 6 only applies to Legacy®Silverwood Note: Malarkey Roofing Products®Inventory SKU numbers for this product: 272 Legacy®and shingles. 273 Legacy®featuring Scotchgard'"Protector from 3M M■ TECHNICAL ASSISTANCE: CORPORATE OFFICE: Malarkey has technical services assistance available. 3131 N.Columbia Blvd. Telephone:503.283.1191 Effective 2/18 Contact Malarkey for details: Portland,OR 97217-7472 or 800.545.1191 Supersedes all previously published data Call weekdays 7:00 am to 5:00 pm PST, P.O. Box 17217 Fax:503.289.7644 Check for most current version at 800.545.1191 or 503.283.1191. Portland,OR 97217-0217 on our website. technicalinquiries@malarkeyroofing.com Page 1 of 1 [WWW.MALARKEYROOFING.COM STEEP SLOPE - RESIDENTIAL - LAMINATE - LEGACY®SHINGLE LINE - SKU:272/273 1 Malarkey Jicy® FE_A. Roofing Products® d &.. jE1i.CY® ScorcIifla1 TECHNICAL PRODUCT DATA SHEET . STEEP SLOPE — RESIDENTIAL — LAMINATE — SKU:272/273 `—I FLEXORTM SBS POLYMER MODIFIED IPAj LAMINATED ARCHITECTURAL SHINGLES irr SOLAR REFLECTANCE TECHNICAL DATA Legacy®Silverwood is listed with the Cool Roof Rating Council. Legacy®Silverwood has tested to these radiative property values: Cool Roof Rating Council ratings are determined for a fixed set of C conditions,and may not be appropriate for determining seasonal energy performance.The actual effect of solar reflectance and thermal COOL ROOF emittance on building performance may vary. RATING COUNCIL RATED Manufacturer of product stipulates that these ratings were determined in accordance with the applicable Cool Roof Rating Council procedures. PRODUCT I LEGACY® (SILVERWOOD) INITIAL WEATHERED SOLAR REFLECTANCE .21 Pending THERMAL EMITTANCE .95 Pending SOLAR REFLECTIVE INDEX(SRI) 23 Pending Related Product ID 0850-0053 Licensed Manufacturer ID:0850 Classification:Production Line TECHNICAL ASSISTANCE: CORPORATE OFFICE: Malarkey has technical services assistance available. 3131 N.Columbia Blvd. Telephone:503.283.1191 Effective 2/18 Contact Malarkey for details: Portland,OR 97217-7472 or 800.545.1191 Supersedes all previously published data Call weekdays 7:00 am to 5:00 pm PST, P.O.Box 17217 Fax:503.289.7644 Check for most current version at 800.545.1191 or 503.283.1191. Portland,OR 97217-0217 on our website. technicalinquiries@malarkeyroofing.com Page 2 of 2 WWW.MALARKEYROOFING.COM STEEP SLOPE — RESIDENTIAL — LAMINATE — VISTA—SHINGLE LINE — SKU:272/273 DMC 15OSS PROFILE DI'exeMetals = Roofing Systems+Custom Fabrication =��I. , . . .. ......• . •__, „ 1l '461.111e II III t in I14 hIU . 111 1 :.1 II .___I___ • _y . _ _ 1" o,p / AgN \, IDEAL APPLICATION COMMERCIAL& RESIDENTIAL ip.,11 _ WEATHER TIGHTNESS WARRANTY APPROVED! lik Our DMC 150SS roof system will lend striking dimension to any architectural design.This versatile 1-1/2" mechanically seamed panel can be curved to a wide range of radiuses and applications - from barrel roofs to conical shapes and more. Concealed fasteners Single lock panel and a floating clip system reduce the effect of thermal stresses on the panels, helping to maintain a beautifully smooth, uniform 111111111101,-. appearance despite fluctuations in temperature. litSt Double lock panel r�ENER6Y 1234 GARDINER LANE,LOUISVILLE,KY40213I 888-321-9630 TOLL-FREE 1502-690-6174 FAX I DREXELMETALS.COM E. STAR �i'-'PARTNER ©2016 Drexel Metals,Inc.All rights reserved.Galvalumeo is a registered trademark of BEIC International,Inc.Drexlume'"is a trademark of Drexel Metals,Inc.ENERGY STAR name and logo are registered U.S.marks and are owned by the U.S.government.Colors shown represent the actual color as closely as possible.To ensure exact color for final approval,a metal color chip is available.Warranty statements mentioned are outlines:complete Limited Warranty information is available on request.No other warranty expressed or implied is applicable. is �c) DrexelVietals =\ _,, DMC 15OSS PROFILE Roofing Systems+Custom Fabrication =�/I. ,ori N v AVAILABLE WIDTHS �2 12,14",16",18",19"or 20"* *Drexel Metals design pressures,wind uplifts and test reports are for specific deck attachments,material gauges,clip spacing and panel widths.A complete specification and listing is available online at www.drexelmetals.com MENIMME SUBSTRATES AVAILABLE •Galvalume®-24ga and 26ga • • • • • • • • • • Drexlumeo-24ga and 26ga •Aluminum-.032" • • • • • II • • • •Copper-16 oz and lead-coated copper • Falzinc ■ ■ I ■ • u • • PROFILE OPTIONS • • Single lock panel valspar • Double lock panel l t rvttrft,we're on it r • Radius panel(single or double lock) FINISHES AND PRODUCT WARRANTY: Single lock panel Available in a variety of coatings and colors by Valspar. II1111 See the Drexel Metals color card for standard colors and 1 paint specifications. �R - L YEAR AAY 35GA YEAR NON PRO-RATEDSUBSTRATE PVDF PAINWT WARRANTY High-performanceVALUME® painted metal-35 roofing Unseamed panel Double lock panel product,carefully tensioned leveled for superior flatness. ALUMINUM SUBSTRATE-35 YEAR WARRANTY IIIPP 35 YEAR NON PRO-RATED PVDF PAINT WARRANTY High-performance painted metal roofing product,carefully tensioned leveled for superior flatness. DREXLUME®SUBSTRATE-25 YEAR WARRANTY Mill finished Galvalume®with a two-sided,clear acrylic finish. �� -`- PRODUCTION OPTIONS �/� - etS ■field - Factory made or field rolled to exact lengths Optional:striation, beads,pencil ribs Underlayment INSTALLATION Can be installed over steel decking with Polylso,or over plywood decking and Drexel Metals MetShield®underlayment. MIIPO SLOPE Minimum slope 2:12 MINIMUM ROOF PITCH 2:12- low roof pitch Testing in accordance with TESTING • UL 580 Wind Uplift(Class 90) •ASTM E1646 Water Infiltration ��vS Sitzt, •TAS 125 Wind Uplift •TAS 100 Wind Driven Rain • UL 1897 Extended Phase •ASTM E1680 Air Infiltration . I� 11=iourny Wind Uplift ASTM E1886 Missile Impact ® � ,u l • UL 2218 Class 4 Hail Impact • INTERNATIONAL •ASTM 2140 Static Pressure Water Head Standards worldwide • UL 790 Class A Fire Rating • Miami-Dade County Approved • UL Environmental - • Florida Building Code Approved SRI Third Party Verified •Texas Department of Insurance Approval MetShield® High-Temp DrexelVietals = Roofing Systems+Custom Fabrication . High-Temperature Features and Benefits Underlayment Applications • Protects the roof structure from water seepage caused by ice dams and wind-driven rains • Resists temperatures up to 250°F without degradation of the adhesive • '� E •Seals around roofing nails, staples and screws ti y',ci lie. o 1 Weather ' Bonds directly to the roof substrate for fast and easy Q,`a� installation without the need for additional adhesives Tightness ill _cam ' ` •Split-release film provides easier,faster installation _ F Warranty' .s` Approved! • Resists cracking, drying and rotting, providing long-term -,- - waterproofing performance and low lifecycle cost •Concealed waterproofing system will not detract from the 4aPPIPo architectural aesthetics of the primary roofing system %e2. ♦ �1��� ��%�� of • Exposed rubberized asphalt bead along the membrane J�_�- _ e edge ensures watertightness of lap seams �"� �¢' F,_ a • Made in USA lib Standards � -.111Z:111:!.: • 45'''' • • UL Classified • ICC-ES ESR#2206 s. •2009 and 2012 International Building Code ' • Florida Building Code Approved Product • Meets ASTM D1970 MetShield 6, .. Storage ���a MetShield roofing underlayment rolls should be stored on High-Temp U n d e r l a y m e n t end, under cover and in areas where the temperature is between 40°and 100°F(4.4°and 38°C). Do not double- stack pallets. Best-in-class Metshield° ice and water Warranty underlayment protects the roof structure MetShield is backed by Drexel's industry-leading warranty. from water seepage caused by ice dams Visit our website for warranty details. and wind-driven rain. Designed specifically for high-temperature applications of metal Installation MetShield underlayment is applied when the roof deck roof installations, it will resist temperatures is dry and the substrate temperature is 40°F(4.4°C)or up to 250° without degradation of the higher. At temperatures below 40°F, nailing or priming adhesive, and self-seals around roofing should be used to temporarily hold the membrane in place while adhesion develops. MetShield is designed to be nails, screws and clips used to install the covered with the primary roofing system and should not be primary roofing system. This high-tensile exposed to sunlight for more than 120 days. strength underlayment is a 40 mil SBS modified bitumen with a UV-resistant anti-slip Moisture: Substrate must be free of any moisture. If polyethylene woven top facer and is required moisture is present, it may inhibit adhesion. under all Drexel Metals roof warranted New construction: Prepare the roof deck by removing all systems. loose objects, dirt, dust and debris. Re-roofing: Remove all old materials from the roof deck in the area to be covered with MetShield underlayment. MetShield° High Temp Underlayment Replace water-damaged sheathing and sweep roof deck Limitations thoroughly. • MetShield should be installed when air, roof deck and membrane temperatures are at or above 40°F(4.4°C). Priming: Priming is not required on clean, dry wood, metal or most polyisocyanurate surfaces. Masonry and • MetShield should not be left exposed to sunlight for more exterior gypsum boards(such as DensDeck®)should be than 120 days. primed using an appropriate primer or adhesive. Some rigid • MetShield membrane should not be folded over the insulation boards with porous or dusty surfaces may require roof edge unless protected by a gutter or other flashing priming to promote initial adhesion. Priming is required materials. on all substrates when air or substrate temperatures are •The primary roof system must be ventilated to prevent below 40°F(4.4°C). Adhesives such as CCW-702, CCW- 702WB, CAV-GRIP°and CCW-AWP are approved for use excessive moisture build-up in the interior structure. with Drexel MetShield. Refer to your local building codes to • Use caution during the installation of the membrane as it determine acceptable product for use in your region. may become slippery when wet or covered with frost. Selection of roof deck or insulation substrate and/or use of • MetShield must not to be used in contact with flexible PVC material. a primer or adhesive are the responsibility of the architect, specifi er or roofing contractor to determine based on the • MetShield not approved for use in foam set tile roof assembly and environmental conditions. applications. Valleys,hips and ridges: Cut MetShield roofing Product Specifications underlayment into manageable lengths. Align over the center of the valley, hip or ridge. Remove release film. Physical Properties Press the middle of the membrane first before working Surface Black/White Engineered toward the edges. For open valleys, cover MetShield Polyolef in Composite roofing underlayment with metal valley liners. Film with Factory-applied Anti-skid Coating Eaves and rakes: Cut MetShield underlayment into 10-15' Membrane Rubberized Asphalt pieces. Remove 2-3' of release film and align the edge of the membrane, sticky side down, so it overhangs the drip Product Characteristic Units Results edge by 3/8"(10 mm). Continue to remove release film and Roll Length feet 66 press as you move across the roof. Use a hand roller and/ Roll Weight lbs 55 or hand pressure to press into place. Overlap end laps Roll Size sq/ft 198 a minimum of 6". MetShield roofing underlayment should Roll Width inches 36 reach a point 2' inside the interior wall line. Local codes may require additional courses. If additional courses are required,the top lap must be at least 3 1/2". Typical Performance Properties Test Method Results Thickness ASTM D1970 40 mils Drip edges: At the rake edge, apply MetShield Low Temperature Flexibility ASTM D1970 45°F underlayment first and place drip edge on top. At the eave, Adhesion to Plywood at 75°F ASTM D1970 35 lbs/ft apply drip edge first and place MetShield underlayment on Lap Seam Adhesion at 75°F ASTM D1970 21 lbs/ft top of the drip edge so that it overhangs drip edge by 3/8" Sealability Around Nail ASTM D1970 Pass (10 mm). For standard installation details,follow the Slip Resistance ASTM D1970 Pass MetShield detail drawings. For non-standard installation Thermal Stability ASTM D1970 Pass instructions, contact your local Drexel Metals representative. Moisture Vapor Permeance ASTM D1970 0.02 perms Water Absorption ASTM D1970 0.5% Metal roof underlayment: Under water-shedding metal Tensile Strength Machine Direction ASTM D412 250 psi roof systems or low-slope metal roofs with a minimum 1/2" Tensile Strength Transverse Direction ASTM D412 1390 psi slope, start at the low point and apply MetShield over the full Elongation at Break Machine Direction ASTM D412 250% surface of the roof deck.Review the metal roofing manufacturer's Elongation at Break Transverse Direction ASTM D412 170% instructions for limitations and precautions. Beginning at the eaves, apply underlayment from the low point to the high Packaging Information point of the roof, running the roll horizontally. Boxes(rolls)per pallet 25 DrexelVietals \ 1234 Gardiner Lane, Louisville, KY 40213 r,ENERGY Roofing Systems+Custom Fabrication ���� 888-321-9630 toll-free • 502-690-6174 fax p"`�� PARTNER www . drexelmetals . com ©2013 Drexel Metals,Inc.All rights reserved.MetShield®is a registered trademark of Drexel Metals,Inc.DensDeck°is a registered trademark of Georgia-Pacific.ENERGY STAR name and logo are registered U.S.marks and are owned by the U.S.government.CAV-GRIP is a trademark of Carlisle Coatings&Waterproofing Incorporated.Warranty statements mentioned are outlines:complete Limited Warranty information is available on request.No other warranty expressed or implied is applicable. Lear about VERSASHIELD® Le f peck 00° eti°n Fire-Resistant Roof Deck Protection prate Helps Protect Your Roo From Moisture While Improving Fire • , Resistance With iii& _,,,L..... L ASS A , a' — Roof Deck . _ L[5 • lir— 1 tec4--- ��� .,ram-"•y............„......„......., �r. •' _ , ., ..., ..... ...... .....,....„........,.... „........_ ......., Quality Roof Deck Protection provides an extra layer of moisture ,mow .........--- protection between your roofing material and the roof deck. =```�- However, in some jurisdictions, roof assemblies are also required '~ - "f to be fire resistant. A Fire-Resistant Roof Deck Protection: -� h • Should provide the very best fire protection: a UL Class A rating ..,.�.W,...--� on most homes and properties • Helps protect against dangerous flame spread and penetration into .0 t... .a.. _ the interior of the property 3.,5, ,so.- • Upgrades UL classification of most metal roofs to a UL Class A rating .. � .: • Helps provide temporary moisture resistance while the roofing system is being installed ® VersaShield®Fire-Resistant Roof Deck Protection •GOOD• /± HOUSEKEEPING is a key part of the GAF Lifetime Roofing GAF °.ea;* .M°� System, and has even earned the prestigious U.S. Only Good Housekeeping Seal (see reverse). _ N II® ■ Fire-Resistant Roof Deck Protection Property Owner's Best Choice TYPICAL APPLICATIONS FOR COMBUSTIBLE DECKS -Maximum Protection... Against fire spread and penetration. -Looks Better... Fiberglass reinforced,so it Iriorp* lies flatter for a better-looking roof(compared I to typical asphalt felts). •Peace Of Mind... Up to a = Roof covering will Lifetime ltd.warranty when Lifetime determine actual assembly* installed on Lifetime Shingle roofs.t L1D.WARRAMY11RM 'See GAF Shingle&AccessoryLtd.Warranty for complete coverage and restrictions.The VERSASHIELD® FIRE-RESISTANT ROOF DECK PROTECTION word"Lifetime'refers to the length of coverage provided by the GAF Shingle&Accessory Ltd.Warrantyand means as long as the original individual owner(s)of a single-family PHYSICAL/PERFORMANCE PROPERTIES detached residence[or the second owners in certain circumstances]owns the property where the shingles and accessories are ins ailed.For owners/structures not meeting the Tensile above criteria,Lifetime coverage is not applicable.Lifetime Ltd.Warranty on accessories requires the use of at least three qualifying GAF accessories and the use of Lifetime Shingles. MD 60 lb./in.width Contact GAF Technical Services at 1-800-ROOF-411 or visit gaf.com for ASTM D146/D828 acceptable non-asphaltic roofing systems and limited warranty coverage. CMD 30 lbfin.width Tear Professional's Best Choice MD ASTMD1922 400grams — 'Increased Productivity... Fire-resistant slip CMD 550 grams sheet AND roof deck protection in one roll. Water Vapor Transmission •Convenient... Will upgrade the UL fire Permeance ASTM E96 3 Perms minimum classification of almost any type of roof. Liquid Water Transmission Test ASTM D4896 I Pass -Great Walkability... Slip-resistant walking surface improves traction on steep slopes. -Easier To Use... Light color provides a cooler VERSASHIELD' FIRE-RESISTANT ROOF DECK PROTECTION working surface. CLASS A RATING LAYER REQUIREMENTS •U.V.Resistant... Resists UV degradation for Wood g up to 60 days** Roofing Roof Min. 15/32" Shake/ Spaced .11010 jape Thickness Plywood Shingle Sheathing UL Listed Stone Direct to 0.013" 1 Layer N/A 1 Layer Specifications (nom.) Coated Steel deck shingle UL Classified or Direct to 0.013" 1 Layer+ N/A 1 Layer+ •3.5 squares(32.5 m2)per roll(excludes laps) Listed Steel deck shingle 30 Felt 30 Felt Any UL•42"(1.07 m)wide, 100 ft. (30.48 m)long Listed Steel lssified or shingle hBa ngleten required 0.013" 1 Layer 2 Layers 1 Layer •Approx.52.5 lb.per roll Any UL Classified or Panel of 0.015" 1 Layer N/A 1 Layer Listed Steel standing seam •Meets or exceeds ASTM D146, Any UL Classified or Panel of 0.016" 1 Layer N/A 1 Layer D226 Type II, D828, D4869 Type IV, Listed Copper standing seam D6757 T e I or T e II Any UL Classified or Shingle 0.016" 1 Layer+ 2 Layers 1 Layer+ yp yp Listed Copper 30 Felt 30 Felt a..a. _� • UL Listed Any UL Classified or Panel or 0.018" 2 Layers N/A N/A — Listed Aluminum shingle --- -- •Miami-Dade County - _ Product Control Approved When installed in accordance with section 4.2.1 of GAF's ESR-2053,VersaShield® Fire-Resistant Roof Deck Protection can be used over existing wood shakes or shingles �..,......y • Florida Building Code Approved as an alternative to the covering materials specified in section 1510.4 of the IBC, -„�_ section R907.4 of the IRC,or section 1513.3 of Chapter 15 Appendix to the UBC. •ICC ESR-2053 •ICC AC-160 VERSASHIELD®FIRE-RESISTANT ROOF DECK PROTECTION `—- *Please refer to Underwriters Laboratories Certifications PACKAGING AND STORAGE Directory for actual assemblies. 3-15 **60-day UV resistance refers to standardized testing conducted i''" to ensure the product will not physically degrade when exposed 25 rolls per pallet to UV.It is NOT related to withstanding water,snow,or wind. 24 pallets per truck,single stacked,600 rolls/truck While VersaShield®Fire-Resistant Roof Deck Protection is water resistant,it is NOT waterproof.DO NOT USE VersaShield® Do NOT double stack Fire Resistant Roof Deck Protection as a temporary roof to Protect from precipitation,moisture,sunlight,and extreme temperatures while in storage protect property or possessions. ® The GAF Lifetime Roofing System pUP��TT TEFTFp has earned the prestigrous Good GAF 'GOOD' Housekeeping Se al,which means that HOUSEKEEPING Good Housekeepingstandsbehind theproducts in thiss!lag stem.(Referto ecy`....,,,,..,,,,.....,,,„.1," sm..*,,OF ,09 Good Housekeeping Ma azaneforits w4FFA,,,,.....,•a.1a consumerprotectaonpoky.Applicable ©2015 GAF 12/15•#608 RESGN222 in US.only.) visit gafcom