HomeMy WebLinkAboutFile Documents.216 S Monarch St.0055.2019 (14).ACBK A( COMcheck Software Version 4.1.1.0
1 Interior Lighting Compliance Certificate
Project Information j — \NENE
Energy Code: 2015 IECC [ o8/21/2o19
Project Title: DUEMANI RESTAURANT
Project Type: Alteration
justinh
Construction Site: Owner/Agent: Designer/Contractor:
216 S MONARCH ST Bryan May SHANE DAVID
ASPEN, CO 81611 Bryan May Architecture DAVID ELECTRIC
706 W Main St CARBONDALE, CO 81623
970-618-9845
Aspen, CO 81611
970-300-2086
bmay@bryanmayarchitecture.com
Allowed Interior Lighting Power
A B C D
Area Category Floor Area Allowed Allowed Watts
(ft2) Watts/ft2 (B X C)
1-RESTAURANT UPPER LEVEL(Dining:Bar Lounge/Leisure) 1867 1.01 1886
2-RESTAURANT LOWER LEVEL(Dining:Bar Lounge/Leisure) 1382 1.01 1396
Total Allowed Watts= 3281
Proposed Interior Lighting Power
A B C D E
Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
RESTAURANT UPPER LEVEL( Dining: Bar Lounge/Leisure 1867 sq.ft.)
Al-RECESSED CANS:Al: DOWNLIGHT: LED Other Fixture Unit 16W: 1 42 15 630
A2-KITCHEN DOWN LIGHTS:A2:DOWNLIGHT:LED Other Fixture Unit 16W: 1 19 15 285
P1-BAR PENDANTS:P1: PENDANT:LED A Lamp 11W: 1 5 100 500
L1-LED STRIP: L1:LED TAPE: LED Linear 8W: 1 1 60 60
SC1-DECORATIVE SCONCES:SC1:SCONCE:LED A Lamp 6W: 1 5 4 22
El-EMERGENCY EXIT LIGHTING: El:LED EGRESS LIGHT:LED Other Fixture Unit 6.5W: 1 2 4 Exempt
Exemption:Exit Signs,Safety or Emergency Lighting
Xl-EXIT SIGNS:Xl:LED EXIT SIGN: LED Other Fixture Unit 6.5W: 1 2 3 Exempt
Exemption:Exit Signs,Safety or Emergency Lighting
RESTAURANT LOWER LEVEL ( Dining: Bar Lounge/Leisure 1382 sq.ft.)
Al-RECESSED CANS:Al: DOWNLIGHT: LED Other Fixture Unit 16W: 1 29 15 435
SC1-DECORATIVE SCONCES:SC1:SCONCE:LED A Lamp 6W: 1 2 4 9
SC2-DECORATIVE SCONCES:SC2:SCONCE:LED A Lamp 3.2W: 2 8 80 640
SC3-DECORATIVE SCONCES:SC3:SCONCE:LED A Lamp 6.5W: 1 2 60 120
Fl-TROFFER LIGHTS:Fl: LED 2X4 TROFFER:LED Panel 40W: 1 14 40 560
El-EMERGENCY EXIT LIGHTING: El:LED EGRESS LIGHT:LED Other Fixture Unit 6.5W: 1 2 4 Exempt
Exemption:Exit Signs,Safety or Emergency Lighting
Xl-EXIT SIGNS:Xl:LED EXIT SIGN: LED Other Fixture Unit 6.5W: 1 2 3 Exempt
Exemption:Exit Signs,Safety or Emergency Lighting
Total Proposed Watts= 3262
RECEIVED
Project Title: DUEMANI RESTAURANT RE08-t d9tg: 02/�1§
Data filename: C:\Users\bmay2\Dropbox\BMA\Projects\2019\1910_Duemani\05_Team\18_Electrician_David\191 ge a , 1 of 6
06_RCP and ComCheck\DUEMANI_BMA.cck ASF'(\!
BUILDING DEPARTMENT
Interior Lighting PASSES
Interior Lighting Compliance Statement
Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the
building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting
systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any
applicable mandatory requirements listed in the Inspection Checklist.
Bryan May, Architect 8/20/19
Name-Title Sign ureld/67 Date
-` Q� CQiOit
IS
BRYAA J AY S
403957
tit". </../0
'1'& DARG�\�
RECEIVED
Project Title: DUEMANI RESTAURANT RE08-tjc,tg: 02/�1§
Data filename: C:\Users\bmay2\Dropbox\BMA\Projects\2019\1910_Duemani\05_Team\18_Electrician_David\191 age , 2 of 6
06_RCP and ComCheck\DUEMANI_BMA.cck ASPEN
BUILDING DEPARTMENT
COMcheck Software Version 4.1.1.0
Inspection Checklist
Energy Code: 2015 IECC
ril
Requirements: 100.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
# Plan Review Complies? Comments/Assumptions
& Req.ID
C103.2 Plans, specifications, and/or EComplies Requirement will be met.
[PR4]1 calculations provide all information Does Not
with which compliance can be
determined for the interior lighting ❑Not Observable
and electrical systems and equipment ❑Not Applicable
and document where exceptions to
the standard are claimed. Information
provided should include interior
lighting power calculations, wattage of
bulbs and ballasts,transformers and
control devices.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier RECEIVED
Project Title: DUEMANI RESTAURANT RID stid9tg: p�$/ 1§
Data filename: C:\Users\bmay2\Dropbox\BMA\Projects\2019\1910_Duemani\05_Team\18_Electrician_David\191 age , 3 of 6
06_RCP and ComCheck\DUEMANI_BMA.cck ASPEN
BUILDING DEPARTMENT
Section
# Rough-In Electrical Inspection Complies? Comments/Assumptions
& Req.ID 1 ,
C405.2.1 I Lighting controls installed to uniformly ❑Complies Requirement will be met.
[EL15]1 I reduce the lighting load by at least ❑Does Not
50%. [Not Observable
I ❑Not Applicable
C405.2.1 ;Occupancy sensors installed in ❑Complies Requirement will be met.
[EL18]1 I required spaces. ❑Does Not
[Not Observable I
❑Not Applicable
C405.2.1, Independent lighting controls installed I❑Complies Requirement will be met.
C405.2.2. per approved lighting plans and all 11=1Does Not
3 manual controls readily accessible and III
Not Observable
[EL23]2 visible to occupants.
❑Not Applicable
C405.2.2. Automatic controls to shut off all ;❑Complies Requirement will be met.
1 i building lighting installed in all ❑Does Not
[EL22]2 ;buildings. ❑Not Observable
I ❑Not Applicable
01 .3 Daylight zones provided with ;❑Complies Requirement will be met.
individual controls that control the ❑Does Not
lights independent of general area
lighting. ❑Not Observable
❑Not Applicable
C405.2.3, I Primary sidelighted areas are Complies Requirement will be met.
C405.2.3. equipped with required lighting ❑Does Not
1, controls.
C405.2.3. ❑Not Observable
2 ❑Not Applicable
[EL20]1
C405.2.3, Enclosed spaces with daylight area ;❑Complies Exception: Requirement does not apply.
C405.2.3. under skylights and rooftop monitors ❑Does Not
1, are equipped with required lighting
C405.2.3. icontrols. Not Observable
3 ❑Not Applicable
[EL21]1
C405.2.4 i Separate lighting control devices for EComplies Requirement will be met.
[EL4]1 specific uses installed per approved Does Not
lighting plans.
ENot Observable
I ❑Not Applicable I
C405.2.4 Additional interior lighting power ❑Complies Requirement will be met.
[EL8]1 allowed for special functions per the ❑Does Not
approved lighting plans and is
automatically controlled and ['Not Observable
separated from general lighting. ❑Not Applicable
1
C405.3 Exit signs do not exceed 5 watts per ❑Complies Requirement will be met.
[EL6]1 face. ❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier EI IE
Project Title: DUEMANI RESTAURANT Rtig-tic,tg: 02/�1§
Data filename: C:\Users\bmay2\Dropbox\BMA\Projects\2019\1910_Duemani\05_Team\18_Electrician_David\19i f1ag�e , 4 of 6
06_RCP and ComCheck\DUEMANI_BMA.cck
ASPEN
BUILDING DEPARTMENT
Section
# Final Inspection Complies? Comments/Assumptions
& Req.ID
C303.3, ;Furnished O&M instructions for ❑Complies Requirement will be met.
C408.2.5. systems and equipment to the ❑Does Not
2 building owner or designated
[F117]3 representative. [Not Observable
❑Not Applicable
C405.4.1 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values.
[F118]1 lighting power is consistent with what ❑Does Not
is shown on the approved lighting
plans, demonstrating proposed watts ['Not Observable
are less than or equal to allowed ❑Not Applicable
watts.
C408.2.5. :Furnished as-built drawings for ❑Complies Requirement will be met.
1 :electric power systems within 90 days ❑Does Not
[F116]3 of system acceptance.
[Not Observable
ENot Applicable
C408.3 1Lighting systems have been tested to ❑Complies Requirement will be met.
[F133]1 ensure proper calibration, adjustment, ❑Does Not
programming, and operation. [Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier RECEIVED
Project Title: DUEMANI RESTAURANT Rtig-tjc21,02/�1§
Data filename: C:\Users\bmay2\Dropbox\BMA\Projects\2019\1910_Duemani\05_Team\18_Electrician_David\19i ge a 5 of 6
06_RCP and ComCheck\DUEMANI_BMA.cck
ASPEN
BUILDING DEPARTMENT
RECEIVED
Project Title: DUEMANI RESTAURANT RE08-tid91/02/ 1§
Data filename: C:\Users\bmay2\Dropbox\BMA\Projects\2019\1910_Duemani\05_Team\18_Electrician_David\191 ge a 6 of 6
06_RCP and ComCheck\DUEMANI_BMA.cck ASPEN
BUILDING DEPARTMENT