HomeMy WebLinkAboutFile Documents.1112 Waters Ave.0024.2019 (19).ARBK Brendan Hamlet From: Justin Hahn <Justin.Hahn@cityofaspen.com> Sent: Tuesday, October 02, 2018 9:19 AM To: Brendan Hamlet Subject: RE: 1112 Waters - Builder of the Day meeting Hello Brendan, Yes,that matches what we had discussed previously. You will also need to fire rate the underside of eaves that are less than 5'to the property lines, similar to the exterior wall. Ideally we would like to see the eave on that corner taken back as far as possible to try and comply with IRC 302.1 (not projecting closer than 2' to the property line), but as this is an existing condition we would accept an alteration that gets it off the neighbor's property as a move towards compliance. Thank you, hig QTYOFAIPQI Justin Hahn Community Development Plans Examiner 201 N. Mill St. Aspen, CO 81611 p 970.429.2784 c 970.319.1610 www.cityofaspen.com www.aspencommunityvoice.com Notice and Disclaimer: This message is intended only for the individual or entity to which it is addressed and may contain information that is confidential and exempt from disclosure pursuant to applicable law. If you are not the intended recipient,please reply to the sender that you have received the message in error and then delete it. Further,the information or opinions contained in this email are advisory in nature only and are not binding on the City of Aspen. If applicable,the information and opinions contain in the email are based on current zoning,which is subject to change in the future,and upon factual representations that may or may not be accurate. The opinions and information contained herein do not create a legal or vested right or any claim of detrimental reliance. From: Brendan Hamlet<bhamlet@zone4architects.com> Sent: Monday, October 1, 2018 2:30 PM To:Justin Hahn <Justin.Hahn@cityofaspen.com> Subject: 1112 Waters- Builder of the Day meeting Hello Justin, Thank you for taking to the time to talk through Building Department implications of our remodel at 1112 Waters Ave. This is what we discussed: 1. Insulation—If existing structure to remain is exposed the cavities must be filled to capacity even though , �` insulation values may not meet current code requirements. l ' 2. Stairs— Existing non-conforming stairs can remain and have finish(es) replaced. 1 02/05/2019 ASPEN BUILDING DEPARTMENT 3. Egress Windows—Existing non-conforming egress windows can be replaced with dimensionally improved windows even though replacement windows may not meet code. 4. Property Line— Existing roof and walls exist within 5' of property line. Roof will be cut back to be contained on site. While improving the exterior envelope a layer of Densglass (or sim) must be installed underneath siding in areas within 5' of property line. Please confirm we can proceed with remodel plans using the aforementioned strategies as basis of design. Thank You, Brendan Hamlet Z O N E P A meT- ARCHITESTS ZONE4 ARC HIIEC'IS Office —970.429.8470 www.zone 4a rc kite c ts.c om RECEIVED 2 02/05/2019 ASPEN BUILDING DEPARTMENT