HomeMy WebLinkAboutFile Documents.63 Smuggler Grove Rd.0049.2018 (20).ARBK SMUGGERGRUVE . , LIGHTING
2oTGER Rs ARCHITECTURAL LIGHTING FIXTURE SCHEDULE i h
DESIGN
GROUP
CATALOG NUMBER MOUNTING
FIXTURE TYPE IMAGE DESCRIPTION MANUFACTURER HOUSING I TRIM 6 ACCESSORIES FINISH LAMP ENERGY EFFICIENCY POWER SUPPLY CONTROL INSTALLATION MATERIAL I IN. NOTES
ENERGY COMPLIANCE:
ALL RECESSED LIGHTING IC-RATED
98.4%OF ALL FIXTURES AND LIGHT BULBS ARE EFFICIENT 1126 EFFICIENT FIXTURES,2 NON-EFFICIENT SOURCES
r " ,, .......i-..,
Al 4 RECESSED ADJUSTABLE LF HVS-1BA-S- 9062-MW WHITE (1)7W 12V MR16,450 HIGH-EFFICACY: INTEGRAL 12V MLV DIM RECESSED GYP s 1"
DOWNLIGHT,40-DEG TILT, ILLUMINATION 015MR16X-AD-TT-1-IC LUMENS,(VERIFY LED<15W MAGNETIC LOW FLANGELESS
5.4"DEPTH IC RATED, CCT), 61 LPW @ 7W VOLTAGE
TRIMLESS SQUARE BEVEL EXPERTCOLOR BY DIMMING
PHILIPS TRANSFORMER
A2 , 4X8"RECESSED ADJUSTABLE LF HVS-2BA-S- 9604-MW WHITE (2)7W 12V MR16,450 HIGH-EFFICACY: INTEGRAL 12V MLV DIM RECESSED GYP 1"
DOWNLIGHT WITH 2 HEADS, ILLUMINATION 015MR16X-AD-TT-1-IC LUMENS,(VERIFY LED<15W MAGNETIC LOW FLANGELESS
All >•� • 40-DEG TILT,5.5"DEPTH IC CCT), 122 LPW @ 14W VOLTAGE
RATED,TRIMLESS SQUARE EXPERTCOLOR BY DIMMING
;=""Q BEVEL PHILIPS TRANSFORMER
C (BY INTERIOR CEILING MOUNT CLOSET FIXTURE BY INTERIOR DESIGNER - - - NON-EFFICIENT I- - -
DESIGNER)
Ll ),_4.,!,;v I.( SURFACE MOUNTED LED PARADIGM LED PL-AMC-1612; PL-FLEXSR590- ALUMINUM LED,4.5W/FT 24V, HIGH-EFFICACY: REMOTE 24V MLV DIM SURFACE -
STRIP IN LENSED ALUMINUM PL-OLC-1612; (VERIFY CCT)-INT-24 (HIDDEN) 420 LM/FT,(VERFY LED<15W MAGNETIC LOW40 MOUNT
CHANNEL,1/2"HEIGHT,5/8" PL-ECL 162; CCT),+90 CRI 93 LPW @ 4.SW DIMMING
WIDTH PL-ECL-1612 DIMMING DRIVER
L2 SURFACE MOUNTED LED PARADIGM LED PL-AMC-1612; PL-FLEXSR590- ALUMINUM LED,4.5W/FT 24V, HIGH-EFFICACY: REMOTE 24V MLV DIM SURFACE - - *APPLY SILICONE PER MFR
(WET) STRIP IN LENSED ALUMINUM PL-OLC-1612; (VERIFY CCT)-INT-24 (HIDDEN) 420 LM/FT,(VERFY LED<15W MAGNETIC LOW MOUNT RECOMMENDATIONS FOR WET
CHANNEL,1/2"HEIGHT,ENDAP PL-EC-1612; CCT),*90 CRI 93 LPW @ 4.5W VOLTAGEIMMINGRATING
WIDTH;SILICONE ENDCAPS PL-ECL-1612 DIMMING DRIVER *CONSULT MFR REGARDING PRE-
FOR WET RATING SILICONE FOR WET MADE LENGTHS
RATING
L3 I 30: g,p I SURFACE MOUNTED HIGH- PARADIGM LED PL-AMC-2415; PL-FLEXDR590- ALUMINUM LED,9W/FT 24V,850 HIGH-EFFICACY: REMOTE 24V MLV DIM SURFACE - -
(HIGH GG:MEDI) OUTPUT LED STRIP IN PL-OLC-2415; (VERIFY CCT)-INT-24 (HIDDEN) LM/FT,(VERFY CCT), LED<15W MAGNETIC LOW MOUNT
OUTPUT) LENSEDICHANNEL,1"WIDTH, PL-EC-2415;L-24 +90 CRI 94 LPW @ 9W V41011 OLTAGE
5/8"HEIGHT PL-ECL-2415 DIMMING DRIVER
L4 - SURFACE MOUNTED LED PARADIGM LED PL-AMC-1616; PL-FLEXDR590- ALUMINUM LED,4.5W/FT 24V, HIGH-EFFICACY: REMOTE 24V MLV DIM SURFACE - -
STRIP IN ANGLED,LENSED PL-OLC-1616; (VERIFY CCT)-INT-24 (HIDDEN) 420 LM/FT,(VERFY LED<15W MAGNETIC LOW MOUNT
ALUMINUM CHANNEL,5/8" PL-EC-1616; CCT),+90 CRI 93 LPW @ 4.5W VOLTAGE
PROFILE PL-ECL-1616 DIMMING DRIVER
L5 lir::v.J a x, SURFACE MOUNTED LED PARADIGM LED PL-CL-(VERIFY CCT)- PL-CL-EC-(SHAPE) ALUMINUM LED,4.5W/FT 24V, HIGH-EFFICACY: REMOTE 24V MLV DIM SURFACE - -
(CLOSET) STRIP IN LENSED ALUMINUM 24-DIM-(SHAPE(- PL-CL-ECL-(SHAPE) (HIDDEN) 420 LM/FT,(VERFY LED<15W MAGNETIC LOW MOUNT
/ CHANNEL-CHANNEL SHAPE (LENGTH) CCT),+90 CRI 93 LPW @ 4.5W VOLTAGE
Y '. : TBD PER CLOSET DETAIL; DIMMING DRIVER
11 FACTORY ASSEMBLES TO
LENGTH WITH CLOSET
RATED STICKER
L6 SURFACE MOUNTED LED PARADIGM LED 17031-LIGER LENS PL-FLEXSR590- BLACK LED,4.5W/FT 24V, HIGH-EFFICACY: REMOTE 24V MLV DIM SEE ARCH. - -
(STAIRS) STRIP IN LENSED ALUMINUM +KLUS LED B1718_K(LENGTH)- (VERIFY CCT)-INT-24 420 LM/FT,(VERFY LED<15W MAGNETIC LOW STAIR DETAIL
CHANNEL,1/2"HEIGHT,5/8" BLACK EXTRUSION CCT),+90 CRI 93 LPW @ 4.5W VOLTAGE
WIDTH;BLACK FINISH-LIGER PDS4 DIMMING DRIVER
LENS
p (BY INTERIOR SUSPENDED DECORATIVE PENDANT BY INTERIOR DESIGNER NON-EFFICIENT- - - - - - -
DESIGNER)
Siran
4"RECESSED ADJUSTABLE LF HVS-1BA-S- 9062-MW-SHCL WHITE (1)7W 12V MR16,450 HIGH-EFFICACY: INTEGRAL 12V MLV DIM RECESSED GYP s 1"
DOWNLIGHT,40-DEG TILT, ILLUMINATION 015MR16X-AD-TT-1-IC LUMENS,VERIFY LED<15W MAGNETIC LOW FLANGELESS
5.4"DEPTH IC RATED, CCT,EXPERTCOLOR 61 LPW @ 7W VOLTAGE
TRIMLESS SQUARE BEVEL BY PHILIPS DIMMING
WITH SHOWER RATING TRANSFORMER
,, ,K,Ate IEE('EIJE
D
7
3/1/18
ASPEN
BUILDING DEPARTMENT
GENERAL FIXTURE SCHEDULE NOTES:
•FIXTURE SCHEDULE MUST BE USED TOGETHER WITH LIGHTING FIXTURE CUTSHEETS FOR COMPLETE SPECIFICATION PACKAGE.
•DISCREPANCIES IN SPECIFICATIONS AND CUTSHEETS SHALL BE BROUGHT TO THE ATTENTION OF 186 FOR SPECIFICATION CONFIRMATION PRIOR TO ORDER.
•FIXTURE SUBSTITUTIONS MUST BE APPROVED IN WRITING BY 186.
•ALL FIXTURES SHALL BE SUPPLIED WITH SPECIFIED LAMPS;ALTERNATE LAMPS MUST BE APPROVED IN WRITING BY 186:
•LOW VOLTAGE HALOGEN FIXTURES TO BE LAMPED WITH LED MR16 LAMPS SPECIFIED BY 186 WHERE NECESSARY TO MEET ENERGY CODE.
•186 WILL PROVIDE BEAMSPREAD PLAN DENOTING BEAMSPREAD OPTIC TYPE AND SPECIFIC LOCATIONS FOR ALL APPLICABLE LIGHTS.
E.C.VERIFICATION PRIOR TO ORDER
•E.C.TO VERIFY THE FOLLOWING PRIOR TO ORDER:
•VERIFY RECESSED HOUSING TYPES(IC,NON-IC,AIRTIGHT,REMODEL)ARE APPROPRIATE FOR EACH MOUNTING LOCATION.
•VERIFY INDICATED FINISHES;TO BE CONFIRMED WITH 186,ARCHITECT OR INTERIOR DESIGNER.
•VERIFY FINISHED CEILING THICKNESS COMPATIBILITY WITH RECESSED HOUSINGS AND TRIMS.
•VERIFY ALL TRANSFORMER SIZES.
•E.C.RESPONSIBLE FOR VERIFICATION OF ALL FIXTURE QUANTITIES AND LENGTHS PRIOR TO ORDER.
•E.C.TO REQUEST BEAMSPREAD PLAN FROM 186 PRIOR TO ORDER OF LAMPS IF NOT ALREADY PROVIDED.
TRANSFORMER AND DRIVER REQUIREMENTS
•E.C.TO VERIFY ALL TRANSFORMER SIZES PRIOR TO ORDER.
•MAGNETIC XFMRS SHALL BE TOROIDAL.
•ELECTRONIC XFMRS FOR MR16 HALOGEN/LED FIXTURES MUST BE"NO-LOAD"TO ACCOMMODATE EITHER TYPE OF LAMPING.
•LOW VOLTAGE HOMERUN WIRES MUST BE SIZED APPROPRIATELY:
•SIZE WIRE TO MINIMIZE VOLTAGE DROP TO FIXTURES.
•SIZE WIRE TO ACCOMMODATE HIGH-AMPERAGE APPLICATIONS SUCH AS 12V MONORAIL,CABLE AND LANDSCAPE LIGHTING.
•STRANDED WIRE IS RECOMMENDED IN THESE APPLICATIONS.
•ALL XFMRS&DRIVERS MUST BE MOUNTED IN AN ACCESSIBLE LOCATION REMOVED FROM THE ROOM'S AIRSPACE SUCH AS A CRAWL SPACE,OR MECHANICAL ROOM.
INSTALLATION OF FIXTURES
•ALL WHITE TRIM RINGS TO BE PAINTED TO MATCH CEILING.
•ELECTRICAL CONTRACTOR TO REMOVE ALL SHIPPING SCREWS FROM RECESSED FIXTURES PRIOR TO SHEETROCK.
•ALL FIXTURES SHALL BE INSTALLED ACCORDING TO MANUFACTURER SPECIFICATIONS AND RECOMMENDATIONS.
•ELECTRICAL CONTRACTOR TO PROVIDE OVER VOLTAGE PROTECTION FOR ALL LED FIXTURES SUCH THAT THERE IS NOT POSSIBILITY TO EXCEED RATED VOLTAGE.
•IF LED TAPE LIGHT THAT HAS BEEN AFFIXED TO A SURFACE IS REMOVED,NEW TAPE LIGHT MUST BE USED IF THE TAPE HAS BEEN ELECTRICALLY COMPROMISED.
•ALL LED TAPE LIGHT SHALL BE MOUNTED TO A HEAT SINK APPROVED BY 186(ALUMINUM CHANNEL,ALUMINUM HEAT SINK TAPE,ETC.)UNLESS SPECIFICALLY DIRECTED OTHERWISE.