Loading...
HomeMy WebLinkAboutFile Documents.63 Smuggler Grove Rd.0049.2018 (21).ARBK l* ISS LIGFItING DESIGN GROU•,INC. 1200 BANNOCK ST. DENVER,CO 50204 TEL1303.534.5350 UWW.IS5GROUIRCOM COLOR LEGEND MR16 LEGEND GENERAL NOTES 1.THE ELECTRICAL CONTRACTOR SHALL INSTALL FIXTURES SPECIFIED BY 186 LIGHTING SP 10 DEGREE SPOT BEAMSPREAD DESIGN GROUP,INC.(186).ANY SUBSTITUTIONS MUST BE APPROVED IN WRITING BY 186. LOW VOLTAGE KEYPAD;FIREPLACE;MOTOR UNAPPROVED ELECTRICAL SUBSTITUTIONS TIRAC SUBJECT TO REPLACEMENT WITH SPECIFIED FIXTURES NFL 25 DEGREE NARROW FLOOD BEAMSPREAD AT THE ELECTRICAL CONTRACTOR'S COST. FL 40 DEGREE FLOOD BEAMSPREAD 2.UPON RECEIPT OF DESIGN DOCUMENT SET,THE ELECTRICAL CONTRACTOR IS TO VERIFY SYSTEM HOMERUN LOAD ALL FIXTURE LEAD TIMES WITH DISTRIBUTOR,AND GET APPROVAL FROM THE GENERAL WFL 60 DEGREE WIDE FLOOD BEAMSPREAD CONTRACTOR THAT THESE LEAD TIMES ARE ACCEPTABLE.IF ANY FIXTURE LEAD TIMES ARE NOT APPROVED BY THE GENERAL CONTRACTOR,THE ELECTRICAL CONTRACTOR IS TO SYSTEM DIMMER/HYBRID KEYPAD CONTACT 186 IMMEDIATELY FOR ASSISTANCE WITH DECREASING LEAD TIMES OR FOR DIFF DIFFUSING LENS ALTERNATE SPECIFICATION.ELECTRICAL CONTRACTOR IS TO FOLLOW THIS PROTOCOL THROUGHOUT PROJECT AS NEW DRAWINGS AND SPECIFICATION SETS ARE ISSUED. NON-SYSTEM DEVICES SOFT SOFT FOCUS LENS 3.THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL APPLIANCE OUTLETS, LIN LINEAR SPREAD LENS DISPOSALS,AND POWER FOR SYSTEMS NOT SHOWN ON 186 PLANS OE POWER FOR HVAC EQUIPMENT,POOL EQUIPMENT,ETC.)INTERIOR DESIGNER IS TO SUPPLY APPLIANCE POWER OUTLETS FROST FROSTED LENS PACKAGE FOR ELECTRICAL REQUIREMENTS.GENERAL CONTRACTOR IS TO SUPPLY ALL POWER REQUIREMENTS FOR SYSTEMS NOT SHOWN ON PLANS.AUDIONIDEO CONTRACTOR CLR CLEAR LENS IS TO SUPPLY ALL POWER REQUIREMENTS FOR ALL NV EQUIPMENT.ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR MEETING ALL APPLICABLE CODES AND GFI LOUV HONEYCOMB LOUVER REQUIREMENTS. 4.ELECTRICAL AND GENERAL CONTRACTORS ARE RESPONSIBLE FOR VERIFYING ALL FIXTURE COUNTS PRIOR TO ORDERING.186 IS NOT RESPONSIBLE FOR ANY RESTOCKING CHARGES DUE TO MIS-ORDERING OR CHANGES BY OTHERS AFTER THE INITIAL ORDER. 5.ALL FIXTURES SHALL BE INSTALLED ACCORDING TO MANUFACTURER SPECIFICATIONS LEGENDAND RECOMMENDATIONS. 6.ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL IC,AIRTIGHT,AND NON-IC FIXTURE LOCATIONS PRIOR TO ORDERING FIXTURES.INSULATION TO BE HELD A MINIMUM OF r 3"FROM ALL NON-IC FIXTURES. C CEILING MOUNTED FIXTURE q HOT ELECTRICAL OUTLET 7.ALL FIXTURE HOUSING SLEEVES AND COLLARS THAT HOLD FIXTURE TRIMS ARE TO BE COMPLETELY FLUSH WITH CEILING AT ELECTRICAL TRIM-OUT.TRIMLESS/FLANGELESS GFI dlt GFI PROTECTED OUTLET RECESSED LIGHTS ARE TO BE MOCKED UP BY THE ELECTRICAL CONTRACTOR PRIOR TO P L9 HANGING PENDANT OR CHANDELIER tt INSTALLATION. WP IP ' LONG HANGING PENDANT OR CHANDELIER,VERIFY FEED LOC. GFI(R1 WEATHERPROOF GFI OUTLET 8.ELECTRICAL CONTRACTOR IS TO NOTIFY 186 IF ANY FIXTURE LOCATIONS MUST MOVE MORE THAN SIX INCHES DUE TO FIELD CONDITIONS. WALL MOUNTED FIXTURE R 1/2 SWITCHED OUTLET 9.ALL SCONCE AND CLOCK OUTLET LOCATIONS SHOWN ON DRAWINGS ARE APPROXIMATE. MIW 9 EXACT LOCATIONS AND HEIGHTS OF WALL SCONCES AND CLOCK OUTLETS FOR PICTURE CO CLOCK OUTLET FOR PICTURE LIGHT I? FULLY SWITCHED OUTLET LIGHTS ARE TO BE VERIFIED WITH THE INTERIOR DESIGNER AND/OR OWNER. 10.ALL LED STRIP INSTALLATIONS ARE TO BE INDIVIDUALLY FED IN LENGTHS NO LONGER ® HOT FLOOR OUTLET THAN THE MAXIMUM LENGTHS RECOMMENDED BY THE MANUFACTURER.ELECTRICAL AND 0 0DJ 0® RECESSED DOWNLIGHT,ROUND OR SQUARE GENERAL CONTRACTOR ARE TO WORK TOGETHER TO ENSURE THERE ARE NO VISIBLE WIRENUTS OR ELECTRICAL CONNECTIONS. O®O S RECESSED ADJUSTABLE ACCENT,ROUND OR SQUARE ® 1/2 SWITCHED FLOOR OUTLET 11.ALL FIXTURES SHALL BE SUPPLIED WITH SPECIFIED LAMPS.WHERE BEAMSPREADS ARE fa FULLY SWITCHED FLOOR OUTLET NOT SPECIFIED,SUPPLY WIDEST BEAMSPREAD AVAILABLE FOR PARTICULAR LAMP TYPE. Ce o MINI-RECESSED DOWNLIGHT OR PUCKLIGHT 12.ALL WIRING IS SHOWN SYMBOLICALLY ON PLANS.ACTUAL REMOTE 0, HOT QUAD FLOOR OUTLET TRANSFORMER/DRIVER LOCATIONS AND HOMERUNS ARE TO BE DETERMINED BY CID 6 RECESSED WALL WASH,ROUND OR SQUARE ELECTRICAL CONTRACTOR AND GENERAL CONTRACTOR.ALL REMOTE TRANSFORMERS/DRIVERS SHALL BE TOROIDAL AND MOUNTED IN A LOCATION REMOVED C 0 T 0 ]TRACK LIGHTING 4 1/4 SWITCHED QUAD FLOOR OUTLET FROM THE ROOM'S AIRSPACE SUCH AS AN ATTIC,CABINET,OR CRAWLSPACE,UNLESS T OTHERWISE NOTED. II 8 8 8 MONOPOINT HEAD H QUAD OUTLET 13.ALL SWITCHED OUTLETS SHOWN ON PLANS SHALL BE WIRED SUCH THAT THE OUTLET Ce MAY BE SWITCHED AT ANY TIME IN THE FUTURE.VERIFY ACTUAL OUTLETS TO SWITCH WITH 1/4 SWITCHED QUAD OUTLET OWNER.ALL HALF-SWITCHED OUTLETS ARE TO HAVE SWITCHED SIDE AND HOT SIDE FED L V' DUAL-HEADED MONOPOINT FROM SAME BREAKER. 220V JB JUNCTION BOX 220V OUTLET 14.EXHAUST FAN LOCATIONS ARE SHOWN SYMBOLICALLY ON THE PLANS.VERIFY EXACT EXHAUST FAN LOCATIONS WITH MECHANICAL CONTRACTOR. yBV 12V OR 24V ROUGH-IN JUNCTION BOX GARAGE DOOR OUTLET 00 15.MOTION SENSORS SHALL BE WALL-MOUNTED AT STANDARD SWITCH HEIGHT UNLESS O OTHERWISE NOTED. 14-CONDUCTOR LOW VOLTAGE ROUGH-IN JUNCTION BOX MOTION SENSOR o @@ 16.ALL LOADS TO BE LANDED ON CONTROL DEVICES IN ORDER DRAWN ON PLANS. T SWITCH 17.CENTER LINE OF TYPICAL SWITCH AND WALLBOX DIMMER BOXES TO BE AT 48"A.F.F. cew 5-CONDUCTOR LOW VOLTAGE ROUGH-IN JUNCTION BOX Q CENTER LINE OF TYPICAL CONTROL SYSTEM KEYPADS TO BE AT 54"A.F.F.(EXCEPT AT /1/ 3-WAY SWITCH BEDROOM HEADBOARD LOCATIONS,ABOVE COUNTERS,AND OTHER NON-TYPICAL KEYPAD LJ� E FIREPLACE IGNITION S LOCATIONS)VERIFY WITH OWNER,ARCHITECT,AND INTERIOR DESIGNER.ELECTRICAL 0 00NTRACTOR AND NV CONTRACTOR TO VERIFY ALL KEYPADS BESIDE BEDS ARE INSTALLED ® SHADE MOTOR/WINDOW MOTOR t4 4-WAY SWITCH CLEAR OF BED HEADBOARD. 18.ELECTRICAL CONTRACTOR TO VERIFY DIMMER AND CONTROL LOCATIONS. O ® EXHAUST FAN �D DIMMER `` 19.ALL LOADS IN REMOTE DIMMING PANELS TO BE LANDED WHERE SHOWN ON PANEL v \i SCHEDULE PROVIDED SHALNOTIF LIGHTING CONTROL CONTR LSEM SEM CONTRACTOROFR. NYL TABLE OF CONTENTS CO - CEILING FAN �SD 3-WAY DIMMER CONTRACTOR SHALL NOTIFY LIGHTING CONTROL SYSTEM OF ANY LOADS �•� THAT HAVE BEEN MOVED FOR ANY REASON. Z E 3 LOW VOLTAGE OR LED STRIP DOOR JAMB SWITCH 1 I LL JS 20.IN ORDER TO INSURE REMOTE ACCESS TO THE LIGHTING CONTROL SYSTEM I PROCESSOR(S),A PHONE OUTLET OR ETHERNET CONNECTION,AS WELL AS AN ELECTRICAL FIBEROPTIC ILLUMINATOR 4 KEYPAD OUTLET IS REQUIRED AT ALL PROCESSOR LOCATIONS. LL p LINE VOLTAGE CONTROL SYSTEM DIMMER 21.ELECTRICAL CONTRA DAN CONTRACTOR ARE TO VERIFY ALL FINISHES OF E.0.001 STANDARD LEGENDS & NOTES CO Q RECESSED LINEAR LIGHT ELECTRICAL DEVICES,LIGHTING TRIMS,AND WALL-BOX DEVICES WITH THE INTERIOR DESIGNER AND/OR OWNERS PRIOR TO ORDERING.IF THESE COLORS OR FINISHES ARE NOT IIE RF TABLETOP KEYPAD VERIFIED,ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR REPLACING EQUIPMENT AND E.2.001 LOWER & GROUND LEVEL LIGHTING PLANS RECESSED LINEAR WALL WASH ��, DEVICES AT NO COST TO THE OWNERS. 0SURFACE-MOUNTED LINEAR LIGHT LJ RF LAMP DIMMER-PLUG INTO HOT OUTLET 22.ELECTRICAL CONTRACTOR TO PROVIDE(10)EXTRA OF IS DEGREE SPOTS,25 DEGREE E.2.002 UPPER LEVEL & CROW'S NEST LIGHTING PLAN DATE REVISION&ISSUE NARROW FLOODS,40 DEGREE FLOODS,AND 60 DEGREE WIDE FLOODS FOR AIMING AND CIRCUIT NUMBER SPARE STOCK FOR OWNER.PROVIDE FLOOD BEAMSPREADS FOR MR-16 LAMPS WHERE 201E-02-06 PERMIT — WALL-RECESSED STEP LIGHT BEAMSPREAD IS NOT DESIGNATED ON 186 BEAMSPREAD DRAWINGS.ELECTRICAL CONTRACTOR TO REQUEST BEAMSPOREAD PLAN FROM 186 PRIOR TO PURCHASE AND IN-GROUND WELL LIGHT TELEPHONE ELECTRICAL TRIM OUT OF MR16 LAMPHOLDERS. 23.ALL ADJUSTABLE ACCENTS TO BE AIMED STRAIGHT DOWN AT ELECTRICAL TRIM-OUT. ® POST TOP LIGHT V DATA OUTLET ELECTRICAL CONTRACTOR TO PROVIDE LADDERS AND PERSONNEL TO ASSIST 186 AND CLIENT WITH FINAL AIMING OF ADJUSTABLE FIXTURES WHEN ARTWORK AND FURNITURE ARE IN PLACE.AIMING SESSIONS ARE TYPICALLY AFTER SUNSET. ENERGY COMPLIANCE V LANDSCAPE ACCENT IN CABLE TELEVISION OUTLET 24.ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR APPROPRIATE SIZING OF ALL ® EXTERIOR PATH LIGHT SATELLITE TELEVISION OUTLET ELECTRICAL CONDUCTORS.12-VOLT SYSTEMS SUCH AS MONORAIL,CABLE,AND LOW VOLT TRACK SHALL BE FED WITH STRANDED WIRE OF AN APPROPRIATE GAUGE FOR LIGHTING LOAD SHOWN ON PLANS.WIRING SHALL BE SIZED SUCH THAT VOLTAGE DROP TO LOW POOL LIGHT ® THERMOSTAT TNFORMER TO IS IEVGREQUIRTHANTG.IFTEACHLIGH,USE MULTI-TAP ALL RECESSED LIGHTING IC-RATED TRANSFORMEROL M S NOTE REQUIRED VOLTAGE AT EACH ARYT. UNDERWATER ACCENT 11rp- TRANSFORMER ALL REFERENCES O ARE ONTLOR LOWANS VOLTAGE SYSTEMS ONLY.THAT ACRE TUAL FT IALLOCAV 98.4% OF ALL FIXTURES AND LIGHT BULBS ARE EFFICIENT RELATED TO LIGHTING ARE ON THE PLANS FOR REFERENCE ONLY.ACTUAL FINAL LOCATIONS TC NV TOUCHSCREEN AND DIMENSIONS ARE TO BE PROVIDED BY OTHERS. 1-HEADED RECESSED MULTIPLE $P SPEAKER 126 EFFICIENT FIXTURES, 2 NON-EFFICIENT FIXTURES (P AND C) 2-HEADED RECESSED MULTIPLE O _ PAGE TITLE. qQ 3-HEADED RECESSED MULTIPLE LEGEND 1 1 \WALL MOUNTED SWING-ARM LAMP &GENERAL NOTES 2 1 OR MAKEUP MIRROR WITH INTEGRAL SWITCH VIF VERIFY IN FIELD STANDARD LEGENDS & NOTES SHEET NUM:O .ooE NO SCALE EE 1 RECEIVED 3/1/18 ASPEN BUILDING DEPARTMENT l* ISS LIGHTING DESIGN GROU•,INC. 1200 BANNOCDK 5T. E E 2 4 � I TEU303.534.5350 LULU J.ISSGROUP.COM LED STRIP IN I N I - CEILINGPOCK �� S LIGHTS DOWN WA L. VERTICAL COVE ASHES 111; 7 INVERSE CO E. WALL BEHIND MI-ROR,VANITY I �4p.�� � II LEA �`� - TO STAIRS II AlT 1107A1 "ALL STAIRS - - / FLOATING VANITY 'ALL STAIRS BELOW 7TRIPUN DER I!! = AN�� SWITCHED i SWITCHED TO SWITCH TTOE ICK - ABOVE 11 S I II�' 1_,,m)_„, A 1 {Q� y� .___. _ _ _ II A2 ;, 'op,5 /, �Iv �/ I I Al' Al t�� LED STRIP 11 I I / iiiiiiia^1 ��L ST mgrAm■ >< C) A Q.....=.\1 UPLIGHT DETAIL . %..`� ,//� I,� u/.// • `=iI/ I STAIR IA2 Lij I J -.. -- ACII - li 11 1 1 10 �1 I H > FO ER ,, ❑ BAR =A1 A1 ram,,' ❑ 11i11 A////� 1� 10031 EXERCISE IP � e„ep \\., 009 •4 J. B.O. FILING v` ,F 4 Y 9'-1 /8"ASV.PLY Ce NON-HIGH-EFFICACY /� „ Al B 0 CEILING �/ � - � : ASV.S'AB \ 0 :'-''' i Y� CLOSETRATED LEDSTRIPATA7 ►'� ® IICOVE UPLIGHTJe Q CLOSET DOORHEADER,ONJAM=ECOVE UPLIGHT 11 �� SWITCHcovE 0.CEIL G D U1../..'', /' it 3D�ej h \ ASV.SLAB ANS� II Jl A2 / LIGHTS DOWNCe /.' lb� ' .RA"t 1.' ' �/44q �'FAN . ENTRY WALLB T x` IN121 /8'i •� g ��� C -� � V.►�i"�/ /, /� ,� �N =n1 TRY II vagi / j- ' / i Eiiiiiiit / ID// / BED5 i �% . / /� / B..celuNr uNc 0/ 001 '/ BATHO BD 5 �� � 9'o�i C1/BO ABV.P Y�� B.O. /, -1 1 8 L, 4 -1 n (Dm O I. , Y 9oi 1/COVEN.S I/\8 �jDD Al- Al l SI / /� q2 COVE UPLIGHT 1 , 7 , m 1111111111111111111111111111111111111111111111111111111111111111111111 'I i/ it J� B.O.CEILING \ i Y !.. I G / �>�fE - 18" �r zzz� 8' 2 7/8"ABV_ , 1,8� ^ �zzzz�z _ ,. /� �� 360°BACKLIT lio® �� — II • li MIRRORS I rill-1 I 1 CEIUN33 LED STRIP AT 380° s 'll INVERSE COVE LIGHTS WALL L� 8- EV.PL III OR TOEKICKFLOATING ANITY BACKLIT 1r II _ I INNER O E MIRRORS --- I LIGHTS DO N C OSET RATED LED STRIP AT IMF------ LED STRIP AT 1 FLOATING VANITY , WALL _wJ C OSET DOOR HEADER,ON JAMB -- OR TOEKICK I 11GII—pCI— S ITCH ❑ tril < DATE REVISION&ISSUE 2018-02-06 PERMIT 1 i OLOWER LEVELI LIGHTING PLAN O GROUND LEVELLIGHTING PLAN 1/4" = 1 -0 1/4" = 1 -0 ENERGY COMPLIANCE PAGE TITLE: ALL RECESSED LIGHTING IC-RATED LOWER LEVEL LIGHTING PLAN 98.4% OF ALL FIXTURES AND LIGHT BULBS ARE EFFICIENT 126 EFFICIENT FIXTURES, 2 NON-EFFICIENT FIXTURES (P AND C) SHEET NUMBER: E.2 .001 RECEIVED 3/1/18 ASPEN BUILDING DEPARTMENT I I Mix LIGHTING DESIGN GROUP,INC. VW 1200 BANNOCK 51. DENVER,CO 50204 - TEL:303.534.5350 UUU186GROUP.COM ICI ICI li !1 Oill I LED STRIP AT o - FLOATING VANITY I I ' 8 \ OR TOEKICK TO STAIRS .ALL STAIRS TO STAIR - BELOW LED ST PLIGHT,AND 'ALL STAIRS SWITCHED SWITCHED BELOW TOGETHER' TO SWITCH STRIP DO IGHT IND ABOVE 1 OA N I OR 1111 TOGETHER` IOI�I �T� 83D :1L3 _1 18"� e �- — 3 3 /l+.— �~ It t SD 3' 23" r22. i IL3 iT ` I Al -' ! 7I A 23" I III _. 8:,1 D PO ADERJ CROW'S NEST IlirtrainL AIR TREAD CH Ilk Al_ R�,i TIT! III TO SWITCHING �1�II -W s �' � HALL -`1-- TC I e .1 203 D :. i Ili- ���.� BELOW TO PENDANT NON-HIGH-EFFICACY _ /�/`_` / ■ SHOWN ABOVE -- I it r_ w� TCHING / O Kg . i C girt BELOW _-_`` TO DOWNLIGHTS - � SHOWN ABOVE �'� YYg2 4� O i L4 , C T C,AI F. 1 / „„, / / ,I I 0"V` , 1 / /: i 0 Q 4% = 2 /* , 41r- '�Nor //t, / iii, �,. to z a ---'4.14" .. 4411114,- (C) < 4 w DATE REVISION&ISSUE 2018-02-06 PERMIT O UPPER LEVEL LIGHTING PLAN O CROW'S NEST LIGHTING PLAN 1/4" = 1 -0 1/4" = 1 -0 ENERGY COMPLIANCE PAGE TITLE: ALL RECESSED LIGHTING IC-RATED UPPER LEVEL LIGHTING PLANS 98.4% OF ALL FIXTURES AND LIGHT BULBS ARE EFFICIENT SHEET NUMBER: 126 EFFICIENT FIXTURES, 2 NON-EFFICIENT FIXTURES (P AND C) C C .2 .002RECEIVED 3/1/18 ASPEN BUILDING DEPARTMENT