ISS LIGFItING DESIGN GROU•,INC.
1200 BANNOCK ST.
DENVER,CO 50204
TEL1303.534.5350
UWW.IS5GROUIRCOM
COLOR LEGEND MR16 LEGEND GENERAL NOTES
1.THE ELECTRICAL CONTRACTOR SHALL INSTALL FIXTURES SPECIFIED BY 186 LIGHTING
SP 10 DEGREE SPOT BEAMSPREAD DESIGN GROUP,INC.(186).ANY SUBSTITUTIONS MUST BE APPROVED IN WRITING BY 186.
LOW VOLTAGE KEYPAD;FIREPLACE;MOTOR UNAPPROVED ELECTRICAL
SUBSTITUTIONS TIRAC SUBJECT TO REPLACEMENT WITH SPECIFIED FIXTURES
NFL 25 DEGREE NARROW FLOOD BEAMSPREAD AT THE ELECTRICAL CONTRACTOR'S COST.
FL 40 DEGREE FLOOD BEAMSPREAD 2.UPON RECEIPT OF DESIGN DOCUMENT SET,THE ELECTRICAL CONTRACTOR IS TO VERIFY SYSTEM HOMERUN LOAD ALL FIXTURE LEAD TIMES WITH DISTRIBUTOR,AND GET APPROVAL FROM THE GENERAL
WFL 60 DEGREE WIDE FLOOD BEAMSPREAD CONTRACTOR THAT THESE LEAD TIMES ARE ACCEPTABLE.IF ANY FIXTURE LEAD TIMES ARE
NOT APPROVED BY THE GENERAL CONTRACTOR,THE ELECTRICAL CONTRACTOR IS TO
SYSTEM DIMMER/HYBRID KEYPAD CONTACT 186 IMMEDIATELY FOR ASSISTANCE WITH DECREASING LEAD TIMES OR FOR
DIFF DIFFUSING LENS ALTERNATE SPECIFICATION.ELECTRICAL CONTRACTOR IS TO FOLLOW THIS PROTOCOL
THROUGHOUT PROJECT AS NEW DRAWINGS AND SPECIFICATION SETS ARE ISSUED.
NON-SYSTEM DEVICES SOFT SOFT FOCUS LENS 3.THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL APPLIANCE OUTLETS,
LIN LINEAR SPREAD LENS DISPOSALS,AND POWER FOR SYSTEMS NOT SHOWN ON 186 PLANS OE POWER FOR HVAC
EQUIPMENT,POOL EQUIPMENT,ETC.)INTERIOR DESIGNER IS TO SUPPLY APPLIANCE
POWER OUTLETS FROST FROSTED LENS PACKAGE FOR ELECTRICAL REQUIREMENTS.GENERAL CONTRACTOR IS TO SUPPLY ALL
POWER REQUIREMENTS FOR SYSTEMS NOT SHOWN ON PLANS.AUDIONIDEO CONTRACTOR
CLR CLEAR LENS IS TO SUPPLY ALL POWER REQUIREMENTS FOR ALL NV EQUIPMENT.ELECTRICAL
CONTRACTOR IS RESPONSIBLE FOR MEETING ALL APPLICABLE CODES AND GFI
LOUV HONEYCOMB LOUVER REQUIREMENTS.
4.ELECTRICAL AND GENERAL CONTRACTORS ARE RESPONSIBLE FOR VERIFYING ALL
FIXTURE COUNTS PRIOR TO ORDERING.186 IS NOT RESPONSIBLE FOR ANY RESTOCKING
CHARGES DUE TO MIS-ORDERING OR CHANGES BY OTHERS AFTER THE INITIAL ORDER.
5.ALL FIXTURES SHALL BE INSTALLED ACCORDING TO MANUFACTURER SPECIFICATIONS
LEGENDAND RECOMMENDATIONS.
6.ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL IC,AIRTIGHT,AND NON-IC
FIXTURE LOCATIONS PRIOR TO ORDERING FIXTURES.INSULATION TO BE HELD A MINIMUM OF
r 3"FROM ALL NON-IC FIXTURES.
C CEILING MOUNTED FIXTURE q HOT ELECTRICAL OUTLET 7.ALL FIXTURE HOUSING SLEEVES AND COLLARS THAT HOLD FIXTURE TRIMS ARE TO BE
COMPLETELY FLUSH WITH CEILING AT ELECTRICAL TRIM-OUT.TRIMLESS/FLANGELESS
GFI dlt GFI PROTECTED OUTLET RECESSED LIGHTS ARE TO BE MOCKED UP BY THE ELECTRICAL CONTRACTOR PRIOR TO
P L9 HANGING PENDANT OR CHANDELIER tt INSTALLATION.
WP
IP ' LONG HANGING PENDANT OR CHANDELIER,VERIFY FEED LOC. GFI(R1 WEATHERPROOF GFI OUTLET 8.ELECTRICAL CONTRACTOR IS TO NOTIFY 186 IF ANY FIXTURE LOCATIONS MUST MOVE
MORE THAN SIX INCHES DUE TO FIELD CONDITIONS.
WALL MOUNTED FIXTURE R 1/2 SWITCHED OUTLET 9.ALL SCONCE AND CLOCK OUTLET LOCATIONS SHOWN ON DRAWINGS ARE APPROXIMATE. MIW 9 EXACT LOCATIONS AND HEIGHTS OF WALL SCONCES AND CLOCK OUTLETS FOR PICTURE
CO CLOCK OUTLET FOR PICTURE LIGHT
I? FULLY SWITCHED OUTLET LIGHTS ARE TO BE VERIFIED WITH THE INTERIOR DESIGNER AND/OR OWNER.
10.ALL LED STRIP INSTALLATIONS ARE TO BE INDIVIDUALLY FED IN LENGTHS NO LONGER
® HOT FLOOR OUTLET THAN THE MAXIMUM LENGTHS RECOMMENDED BY THE MANUFACTURER.ELECTRICAL AND 0
0DJ 0® RECESSED DOWNLIGHT,ROUND OR SQUARE GENERAL CONTRACTOR ARE TO WORK TOGETHER TO ENSURE THERE ARE NO VISIBLE
WIRENUTS OR ELECTRICAL CONNECTIONS.
O®O S RECESSED ADJUSTABLE ACCENT,ROUND OR SQUARE ® 1/2 SWITCHED FLOOR OUTLET
11.ALL FIXTURES SHALL BE SUPPLIED WITH SPECIFIED LAMPS.WHERE BEAMSPREADS ARE
fa FULLY SWITCHED FLOOR OUTLET NOT SPECIFIED,SUPPLY WIDEST BEAMSPREAD AVAILABLE FOR PARTICULAR LAMP TYPE. Ce
o MINI-RECESSED DOWNLIGHT OR PUCKLIGHT
12.ALL WIRING IS SHOWN SYMBOLICALLY ON PLANS.ACTUAL REMOTE
0, HOT QUAD FLOOR OUTLET TRANSFORMER/DRIVER LOCATIONS AND HOMERUNS ARE TO BE DETERMINED BY
CID
6 RECESSED WALL WASH,ROUND OR SQUARE ELECTRICAL CONTRACTOR AND GENERAL CONTRACTOR.ALL REMOTE
TRANSFORMERS/DRIVERS SHALL BE TOROIDAL AND MOUNTED IN A LOCATION REMOVED
C 0 T 0 ]TRACK LIGHTING 4 1/4 SWITCHED QUAD FLOOR OUTLET FROM THE ROOM'S AIRSPACE SUCH AS AN ATTIC,CABINET,OR CRAWLSPACE,UNLESS
T OTHERWISE NOTED.
II 8 8 8 MONOPOINT HEAD H QUAD OUTLET 13.ALL SWITCHED OUTLETS SHOWN ON PLANS SHALL BE WIRED SUCH THAT THE OUTLET
Ce
MAY BE SWITCHED AT ANY TIME IN THE FUTURE.VERIFY ACTUAL OUTLETS TO SWITCH WITH
1/4 SWITCHED QUAD OUTLET OWNER.ALL HALF-SWITCHED OUTLETS ARE TO HAVE SWITCHED SIDE AND HOT SIDE FED L
V' DUAL-HEADED MONOPOINT FROM SAME BREAKER.
220V
JB JUNCTION BOX 220V OUTLET 14.EXHAUST FAN LOCATIONS ARE SHOWN SYMBOLICALLY ON THE PLANS.VERIFY EXACT
EXHAUST FAN LOCATIONS WITH MECHANICAL CONTRACTOR.
yBV 12V OR 24V ROUGH-IN JUNCTION BOX GARAGE DOOR OUTLET
00 15.MOTION SENSORS SHALL BE WALL-MOUNTED AT STANDARD SWITCH HEIGHT UNLESS O
OTHERWISE NOTED.
14-CONDUCTOR LOW VOLTAGE ROUGH-IN JUNCTION BOX MOTION SENSOR o
@@ 16.ALL LOADS TO BE LANDED ON CONTROL DEVICES IN ORDER DRAWN ON PLANS.
T SWITCH 17.CENTER LINE OF TYPICAL SWITCH AND WALLBOX DIMMER BOXES TO BE AT 48"A.F.F.
cew 5-CONDUCTOR LOW VOLTAGE ROUGH-IN JUNCTION BOX Q
CENTER LINE OF TYPICAL CONTROL SYSTEM KEYPADS TO BE AT 54"A.F.F.(EXCEPT AT /1/
3-WAY SWITCH BEDROOM HEADBOARD LOCATIONS,ABOVE COUNTERS,AND OTHER NON-TYPICAL KEYPAD LJ�
E FIREPLACE IGNITION S LOCATIONS)VERIFY WITH OWNER,ARCHITECT,AND INTERIOR DESIGNER.ELECTRICAL 0
00NTRACTOR AND NV CONTRACTOR TO VERIFY ALL KEYPADS BESIDE BEDS ARE INSTALLED
® SHADE MOTOR/WINDOW MOTOR t4 4-WAY SWITCH CLEAR OF BED HEADBOARD.
18.ELECTRICAL CONTRACTOR TO VERIFY DIMMER AND CONTROL LOCATIONS. O
® EXHAUST FAN �D DIMMER ``
19.ALL LOADS IN REMOTE DIMMING PANELS TO BE LANDED WHERE SHOWN ON PANEL v
\i SCHEDULE PROVIDED SHALNOTIF LIGHTING CONTROL CONTR LSEM SEM CONTRACTOROFR. NYL TABLE OF CONTENTS CO -
CEILING FAN �SD 3-WAY DIMMER CONTRACTOR SHALL NOTIFY LIGHTING CONTROL SYSTEM OF ANY LOADS
�•� THAT HAVE BEEN MOVED FOR ANY REASON. Z
E 3 LOW VOLTAGE OR LED STRIP DOOR JAMB SWITCH 1 I
LL JS 20.IN ORDER TO INSURE REMOTE ACCESS TO THE LIGHTING CONTROL SYSTEM I
PROCESSOR(S),A PHONE OUTLET OR ETHERNET CONNECTION,AS WELL AS AN ELECTRICAL
FIBEROPTIC ILLUMINATOR 4 KEYPAD OUTLET IS REQUIRED AT ALL PROCESSOR LOCATIONS. LL
p LINE VOLTAGE CONTROL SYSTEM DIMMER 21.ELECTRICAL CONTRA DAN CONTRACTOR ARE TO VERIFY ALL FINISHES OF E.0.001 STANDARD LEGENDS & NOTES CO Q
RECESSED LINEAR LIGHT ELECTRICAL DEVICES,LIGHTING TRIMS,AND WALL-BOX DEVICES WITH THE INTERIOR
DESIGNER AND/OR OWNERS PRIOR TO ORDERING.IF THESE COLORS OR FINISHES ARE NOT
IIE RF TABLETOP KEYPAD VERIFIED,ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR REPLACING EQUIPMENT AND E.2.001 LOWER & GROUND LEVEL LIGHTING PLANS
RECESSED LINEAR WALL WASH ��, DEVICES AT NO COST TO THE OWNERS.
0SURFACE-MOUNTED LINEAR LIGHT LJ RF LAMP DIMMER-PLUG INTO HOT OUTLET 22.ELECTRICAL CONTRACTOR TO PROVIDE(10)EXTRA OF IS DEGREE SPOTS,25 DEGREE E.2.002 UPPER LEVEL & CROW'S NEST LIGHTING PLAN DATE REVISION&ISSUE
NARROW FLOODS,40 DEGREE FLOODS,AND 60 DEGREE WIDE FLOODS FOR AIMING AND
CIRCUIT NUMBER SPARE STOCK FOR OWNER.PROVIDE FLOOD BEAMSPREADS FOR MR-16 LAMPS WHERE 201E-02-06 PERMIT
— WALL-RECESSED STEP LIGHT BEAMSPREAD IS NOT DESIGNATED ON 186 BEAMSPREAD DRAWINGS.ELECTRICAL
CONTRACTOR TO REQUEST BEAMSPOREAD PLAN FROM 186 PRIOR TO PURCHASE AND
IN-GROUND WELL LIGHT TELEPHONE ELECTRICAL TRIM OUT OF MR16 LAMPHOLDERS.
23.ALL ADJUSTABLE ACCENTS TO BE AIMED STRAIGHT DOWN AT ELECTRICAL TRIM-OUT.
® POST TOP LIGHT V DATA OUTLET ELECTRICAL CONTRACTOR TO PROVIDE LADDERS AND PERSONNEL TO ASSIST 186 AND
CLIENT WITH FINAL AIMING OF ADJUSTABLE FIXTURES WHEN ARTWORK AND FURNITURE ARE IN PLACE.AIMING SESSIONS ARE TYPICALLY AFTER SUNSET. ENERGY
COMPLIANCE
V LANDSCAPE ACCENT IN CABLE TELEVISION OUTLET
24.ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR APPROPRIATE SIZING OF ALL
® EXTERIOR PATH LIGHT SATELLITE TELEVISION OUTLET ELECTRICAL CONDUCTORS.12-VOLT SYSTEMS SUCH AS MONORAIL,CABLE,AND LOW VOLT
TRACK SHALL BE FED WITH STRANDED WIRE OF AN APPROPRIATE GAUGE FOR LIGHTING
LOAD SHOWN ON PLANS.WIRING SHALL BE SIZED SUCH THAT VOLTAGE DROP TO LOW
POOL LIGHT ® THERMOSTAT TNFORMER TO IS IEVGREQUIRTHANTG.IFTEACHLIGH,USE MULTI-TAP ALL RECESSED LIGHTING IC-RATED
TRANSFORMEROL M S NOTE REQUIRED VOLTAGE AT EACH ARYT.
UNDERWATER ACCENT 11rp- TRANSFORMER ALL REFERENCES O ARE ONTLOR LOWANS VOLTAGE SYSTEMS ONLY.THAT ACRE TUAL
FT IALLOCAV 98.4% OF ALL FIXTURES AND LIGHT BULBS ARE EFFICIENT
RELATED TO LIGHTING ARE ON THE PLANS FOR REFERENCE ONLY.ACTUAL FINAL LOCATIONS
TC NV TOUCHSCREEN AND DIMENSIONS ARE TO BE PROVIDED BY OTHERS.
1-HEADED RECESSED MULTIPLE $P SPEAKER 126 EFFICIENT FIXTURES, 2 NON-EFFICIENT FIXTURES (P AND C)
2-HEADED RECESSED MULTIPLE O
_ PAGE TITLE.
qQ 3-HEADED RECESSED MULTIPLE LEGEND
1 1 \WALL MOUNTED SWING-ARM LAMP &GENERAL NOTES
2 1 OR MAKEUP MIRROR WITH INTEGRAL SWITCH VIF VERIFY IN FIELD
STANDARD LEGENDS & NOTES SHEET NUM:O .ooE
NO SCALE EE
1
RECEIVED
3/1/18
ASPEN
BUILDING DEPARTMENT
l*
ISS LIGHTING DESIGN GROU•,INC.
1200 BANNOCDK 5T.
E
E
2
4
� I TEU303.534.5350
LULU J.ISSGROUP.COM
LED STRIP IN I N I -
CEILINGPOCK �� S
LIGHTS DOWN WA L. VERTICAL COVE ASHES
111; 7
INVERSE CO E. WALL BEHIND MI-ROR,VANITY I �4p.�� � II
LEA �`� - TO STAIRS II AlT 1107A1
"ALL STAIRS - - / FLOATING VANITY 'ALL STAIRS BELOW
7TRIPUN DER I!!
= AN�� SWITCHED i
SWITCHED TO SWITCH TTOE ICK -
ABOVE 11 S
I II�'
1_,,m)_„, A 1
{Q� y�
.___. _ _ _
II A2 ;, 'op,5 /, �Iv �/ I I Al' Al
t�� LED STRIP 11 I I
/ iiiiiiia^1 ��L ST mgrAm■ >< C) A
Q.....=.\1 UPLIGHT DETAIL . %..`� ,//� I,� u/.// • `=iI/ I STAIR IA2
Lij I J -.. -- ACII
- li
11 1
1
10
�1
I H >
FO ER
,, ❑ BAR =A1 A1 ram,,' ❑ 11i11
A////� 1� 10031 EXERCISE IP � e„ep
\\., 009 •4 J. B.O. FILING
v` ,F 4 Y 9'-1 /8"ASV.PLY
Ce
NON-HIGH-EFFICACY /� „ Al
B 0 CEILING �/
� - � : ASV.S'AB \ 0 :'-'''
i Y� CLOSETRATED LEDSTRIPATA7 ►'� ® IICOVE UPLIGHTJe Q CLOSET DOORHEADER,ONJAM=ECOVE UPLIGHT 11 �� SWITCHcovE
0.CEIL G D U1../..'',
/' it 3D�ej h \ ASV.SLAB ANS� II Jl A2 / LIGHTS DOWNCe
/.' lb� ' .RA"t 1.' ' �/44q �'FAN . ENTRY WALLB T x` IN121
/8'i •� g ��� C -� � V.►�i"�/ /, /� ,� �N =n1 TRY II
vagi / j- ' / i Eiiiiiiit / ID// / BED5 i �% . / /� / B..celuNr uNc 0/ 001 '/ BATHO BD 5 �� � 9'o�i C1/BO ABV.P Y�� B.O. /, -1 1 8 L, 4 -1 n (Dm O
I.
, Y 9oi 1/COVEN.S I/\8 �jDD Al- Al l SI / /� q2
COVE UPLIGHT 1
, 7 , m 1111111111111111111111111111111111111111111111111111111111111111111111
'I i/ it J� B.O.CEILING \ i
Y !.. I G
/ �>�fE - 18" �r zzz� 8' 2 7/8"ABV_ , 1,8� ^
�zzzz�z _ ,. /�
�� 360°BACKLIT lio® ��
— II • li
MIRRORS I rill-1 I 1 CEIUN33 LED STRIP AT 380°
s 'll INVERSE COVE LIGHTS WALL L� 8- EV.PL III OR TOEKICKFLOATING ANITY BACKLIT
1r II _ I INNER O E MIRRORS
--- I LIGHTS DO N C OSET RATED LED STRIP AT
IMF------ LED STRIP AT 1
FLOATING VANITY , WALL _wJ C OSET DOOR HEADER,ON JAMB
-- OR TOEKICK I 11GII—pCI— S ITCH ❑ tril <
DATE REVISION&ISSUE
2018-02-06 PERMIT
1
i
OLOWER LEVELI LIGHTING PLAN O GROUND LEVELLIGHTING PLAN
1/4" = 1 -0 1/4" = 1 -0
ENERGY COMPLIANCE
PAGE TITLE:
ALL RECESSED LIGHTING IC-RATED LOWER LEVEL
LIGHTING PLAN
98.4% OF ALL FIXTURES AND LIGHT BULBS ARE EFFICIENT
126 EFFICIENT FIXTURES, 2 NON-EFFICIENT FIXTURES (P AND C) SHEET NUMBER:
E.2 .001
RECEIVED
3/1/18
ASPEN
BUILDING DEPARTMENT
I I Mix LIGHTING DESIGN GROUP,INC.
VW
1200 BANNOCK 51.
DENVER,CO 50204
- TEL:303.534.5350
UUU186GROUP.COM
ICI ICI
li !1
Oill I
LED STRIP AT o -
FLOATING VANITY I I ' 8 \
OR TOEKICK
TO STAIRS
.ALL STAIRS TO STAIR -
BELOW LED ST PLIGHT,AND 'ALL STAIRS
SWITCHED SWITCHED BELOW
TOGETHER' TO SWITCH STRIP DO IGHT IND
ABOVE 1 OA N I OR 1111 TOGETHER`
IOI�I �T� 83D :1L3 _1 18"� e �- — 3 3 /l+.— �~
It
t SD 3' 23" r22. i IL3 iT ` I Al
-' ! 7I A
23" I
III _. 8:,1 D PO ADERJ CROW'S NEST
IlirtrainL AIR TREAD CH Ilk Al_ R�,i
TIT!
III TO SWITCHING
�1�II
-W
s �' � HALL
-`1-- TC
I e .1 203 D :.
i Ili- ���.� BELOW
TO PENDANT NON-HIGH-EFFICACY _ /�/`_`
/ ■ SHOWN ABOVE -- I it
r_ w� TCHING / O
Kg .
i C girt BELOW _-_``
TO DOWNLIGHTS - �
SHOWN ABOVE
�'� YYg2 4� O
i L4
, C T
C,AI
F.
1 /
„„,
/ / ,I I 0"V` ,
1 / /: i 0 Q
4% = 2
/* ,
41r-
'�Nor //t, / iii, �,. to z
a ---'4.14" .. 4411114,- (C) <
4 w
DATE REVISION&ISSUE
2018-02-06 PERMIT
O
UPPER LEVEL LIGHTING PLAN O CROW'S NEST LIGHTING PLAN
1/4" = 1 -0 1/4" = 1 -0
ENERGY COMPLIANCE
PAGE TITLE:
ALL RECESSED LIGHTING IC-RATED UPPER LEVEL
LIGHTING PLANS
98.4% OF ALL FIXTURES AND LIGHT BULBS ARE EFFICIENT
SHEET NUMBER:
126 EFFICIENT FIXTURES, 2 NON-EFFICIENT FIXTURES (P AND C) C C .2 .002RECEIVED