Loading...
HomeMy WebLinkAboutFile Documents.506 E Main St.0054.2019 (6).ACBK N N o INSTALLATION GENERAL NOTES 1. THE SYSTEM DESIGN ASSUMES A MINIMUM DYNAMIC PRESSURE FOR THE 6. PROVIDE THE FOLLOWING COMPONENTS TO THE OWNER PRIOR TO THE c�v IRRIGATION SYSTEM OF 45 PSI(MIN REQUIRED),AT A MAXIMUM DISCHARGE COMPLETION OF THE PROJECT: ? . c OF 12 GPM AT THE 1 1/4-INCH IRRIGATION POINT-OF-CONNECTION(POC). c.n o A. TWO(2)OPERATING KEYS FOR EACH TYPE OF MANUALLY y ,.. 2. READ THOROUGHLY AND BECOME FAMILIAR WITH THE SPECIFICATIONS AND OPERATED VALVES. u INSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO ¢a m CONSTRUCTION. 7. SELECT NOZZLES FOR SPRAY AND ROTARY SPRINKLERS WITH ARCS WHICH ;7, _c PROVIDE COMPLETE AND ADEQUATE COVERAGE WITH MINIMUM OVERSPRAY C 7 3. COORDINATE UTILITY LOCATES("CALL BEFORE YOU DIG")OF UNDERGROUND FOR THE SITE CONDITIONS.CAREFULLY ADJUST THE RADIUS OF THROW AND 0 m 2- UTILITIES PRIOR TO CONSTRUCTION. ARC OF COVERAGE OF EACH ROTARY SPRINKLER TO PROVIDE THE BEST (Dn - % PERFORMANCE. 4. DO NOT PROCEED WITH THE INSTALLATION OF THE IRRIGATION SYSTEM ¢m %A WHEN IT IS OBVIOUS IN THE FIELD THAT OBSTRUCTIONS OR GRADE 8. THE IRRIGATION CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF =. <9 DIFFERENCES EXIST THAT MIGHT NOT HAVE BEEN CONSIDERED IN THE IRRIGATION SLEEVING.SLEEVES ARE REQUIRED FOR BOTH PIPING AND O a ENGINEERING.IF DISCREPANCIES IN CONSTRUCTION DETAILS,LEGEND, ELECTRICAL WIRING AT EACH HARDSCAPE CROSSING.COORDINATE cr,= d 8. NOTES,OR SPECIFICATIONS ARE DISCOVERED,BRING ALL SUCH INSTALLATION OF SLEEVING WITH OTHER TRADES.ANY PIPE OR WIRE WHICH =`c� S OBSTRUCTIONS OR DISCREPANCIES TO THE ATTENTION OF THE OWNER'S PASSES BENEATH EXISTING HARDSCAPE WHERE SLEEVING WAS NOT 'mt6 5 REPRESENTATIVE. INSTALLED WILL REQUIRE HORIZONTAL BORING BY THE IRRIGATION U y CONTRACTOR.PIPE SLEEVES SHALL BE SIZED TWICE THE NOMINAL SIZE OF 5. THE DRAWINGS ARE DIAGRAMMATIC.THEREFORE,THE FOLLOWING SHOULD THE PIPE PASSING THROUGH. Z BE NOTED: -24 z 4 9. INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN 1_ A. ALTHOUGH IRRIGATION COMPONENTS MAY BE SHOWN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE Cl) _ OUTSIDE PLANTING AREAS FOR CLARITY,INSTALL LOCAL ELECTRIC UTILITY CODES. .'�_d ri/i/.,0•J IRRIGATION PIPE AND WIRING IN LANDSCAPED AREAS WHENEVER POSSIBLE. 10. THE FOLLOWING SHOULD BE NOTED REGARDING PIPE SIZING:IF A SECTION OF UNSIZED PIPE IS LOCATED BETWEEN THE IDENTICALLY SIZED SECTIONS, (` B. TREE AND SHRUB LOCATIONS AS SHOWN ON LANDSCAPE THE UNSIZED PIPE IS THE SAME NOMINAL SIZE AS THE TWO SIZED SECTIONS. PLANS TAKE PRECEDENCE OVER IRRIGATION EQUIPMENT LOCATIONS. THE UNSIZED PIPE SHOULD NOT BE CONFUSED WITH THE DEFAULT PIPE SIZEwatil AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM,PLANTING NOTED IN THE LEGEND. MATERIALS,AND ARCHITECTURAL FEATURES. 11. INSTALL ONE(1)#14 AWG TWO-WIRE PAIR ON TWO-WIRE SYSTEMS,FOR USE PITKI N COUNTY C. USE ONLY STANDARD TEES AND ELBOW FITTINGS.USE OF TEES IN THE AS SPARES.INSTALL SPARE WIRES FROM CONTROLLER LOCATION TO EACH COURTHOUSE BULLNOSE CONFIGURATION,OR USE OF CROSS TYPE FITTINGS IS NOT DEAD-END OF MAINLINE.COIL 3 FEET OF WIRE IN VALVE BOX. ALLOWED. ADDRESS: 506 E. MAIN ST.STE.300 ASPEN,CO 81611 PARCEL# 27370734347851 DATE: 2019.05.10 ISSUE: FOR PLANNING PURPOSES ONLY (NOT FOR CONSTRUCTION) IRRIGATION LEGEND DRAWN BY:BI CHECKED BY:MR I I SLEEVES:CLASS 200 PVC HISTORY: I-POINT-OF-CONNECTION ASSEMBLY DATE ISSUE - MAINLINE PIPE:CLASS 200 PVC 2019.05.22 1 1/4-INCH SIZE UNLESS OTHERWISE INDICATED - LATERAL PIPE TO SPRINKLERS:CLASS 200 PVC 1-INCH SIZE UNLESS OTHERWISE INDICATED LATERAL PIPE TO DRIP EMITTERS:UV RADIATION RESISTANT POLYETHYLENE 3/4-INCH SIZE UNLESS OTHERWISE INDICATED,ROUTING IS DIAGRAMMATIC H ISOLATION GATE VALVE ASSEMBLY:MATCO 514 O QUICK COUPLING VALVE ASSEMBLY:RAINBIRD5RC CONSTRUCTION NOTES CITY OF ASPEN GENERAL NOTES & REMOTE CONTROL VALVE ASSEMBLY FOR SPRINKLER LATERALS: O THE IRRIGATION SYSTEM POINT-OF-CONNECTION(POC)SHALL BE 1. APPLICANT IS RESPONSIBLE FOR ASSURING OPERATING PRESSURE AT EACH WEATHERMATIC MAX-DW SERIES(SIZED PER PLAN) DOWNSTREAM OF THE EXISTING 1 1/4-INCH IRRIGATION MAINLINE AND EMISSION DEVICE IS WITHIN THE MANUFACTURER'S RECOMMENDED CONTROL WIRE PATH AT THE APPROXIMATE LOCATION SHOWN.MAKE NEW PRESSURE RANGE FOR OPTIMAL PERFORMANCE.IF PRESSURE IS NOT ® REMOTE CONTROL DRIP VALVE ASSEMBLY:RAIN BIRD XCZ-PRB-100-COM CONNECTION AND ROUTE NEW MAINLINE AS SHOWN.VERIFY EXACT WITHIN THE PREFERRED RANGE,ACTIONS DESCRIBED IN SECTION 5.1.11 OF LOCATION OF POC WITH OWNER'S REPRESENTATIVE. THE WATER EFFICIENT LANDSCAPING STANDARDS MUST BE TAKEN. m FLUSH CAP ASSEMBLY 2. SPRINKLERS WITHIN INDIVIDUAL IRRIGATION ZONE SHALL HAVE MATCHED OCONTRACTOR SHALL MAKE REPAIRS AND MAINTAIN EXISTING IRRIGATION PRECIPITATION RATES,UNLESS OTHERWISE DIRECTED BY THE st UNCONNECTED PIPE CROSSING EQUIPMENT IN THIS APPROXIMATE LOCATION. MANUFACTURER'S RECOMMENDATIONS. 3. ENSURE THERE IS HIGHEST POSSIBLE DISTRIBUTION UNIFORMITY,AND HEAD-TO-HEAD COVERAGE. 4. AN IRRIGATION MAINTENANCE SCHEDULE AND IRRIGATION MANAGEMENT INDICATES CONTROLLER AND STATION NUMBER PLAN IS REQUIRED AS DESCRIBED IN SECTION 5.4 THROUGH 5.8 OF THE ME i---- m' ��INDICATES LATERAL DISCHARGE(GPM) STANDARDS. ® � 5. SLOPES GREATER THAN TWENTY-FIVE PERCENT(25%)SHALL NOT USE INDICATES VALVE SIZE(INCHES) IRRIGATION PIPE SCHEDULE SPRINKLERS WITH AN APPLICATION RATE EXCEEDING 0.75 INCHES PER IffEl �� INDICATES LANDSCAPE APPLICATION OR APPLICATION RATE(IN/HR) CLASS 200 PVC PIPE HOUR.REFER TO CITY OF ASPEN WATER EFFICIENT LANDSCAPING 30 STANDARDS SECTION 5.2.4 FOR EXCEPTIONS. INDICATES DESIGN PRESSURE(PSI) SIZE FLOW(GPM) O e ■POP-UP SPRAY SPRINKLER:WEATHERMATIC MAX6PRS30-CV W/RAIN BIRD U-SERIES NOZZLES 1-INCH 0-15 ENSURE THE FOLLOWING: PRESSURE:30 PSI RADIUS:8 FEET 1.25-INCH 16-25 1. TURF GRASS SPRINKLER HEADS SHALL HAVE A DISTRIBUTION UNIFORMITY ,TAMP PER DISCIPLINE FLOW(GPM):Q-0.26 H-0.52 F-1.05 26-35 OF 0.65 OR HIGHER USING THE PROTOCOL DEFINED IN ASABE/ICC 802-2014. 1.5-INCH 2. POP-UPS IN TURF AREAS HAVE A MINIMUM HEIGHT OF 6". S e •POP-UP SPRAY SPRINKLER'WEATHERMATIC MAX6PRS30-CV W/RAIN BIRD U-SERIES NOZZLES 2-INCH 36-55 PRESSURE:30 PSI RADIUS:10 FEET FLOW(GPM):Q-0.41 H-0.82 F-1.64 2.5-INCH 56-80 3-INCH 81-110 ,,T,,,,,,,,,,.R,A"PR A n ♦POP-UP SPRAY SPRINKLER'WEATHERMATIC MAX6PRS30-CV W/RAIN BIRD U-SERIES NOZZLES 4-INCH 111-200 SHEET TITLE: PRESSURE:30 PSI RADIUS:12 FEET FLOW(GPM):Q-0.65 H-1.30 F-2.60 IF THERE IS A DISCREPANCY BETWEEN PIPE SIZES SHOWN ON THE DRAWINGS AND THIS PIPE SCHEDULE,IT IS THE RESPONSIBILITY OF e e •POP-UP SPRAY SPRINKLER:WEATHERMATIC MAX6PRS30-CV W/RAIN BIRD U-SERIES NOZZLES CLARIFICATION.ECONTRACTOR C OR TO CONTACT THE IRRIGATION DESIGNER FOR IRRIGATION PRESSURE:30 PSI RADIUS:15 FEET FLOW(GPM):Q-0.92 H-1.85 F-3.70 LEGEND & O O O POP-UP ROTATING SPRAY SPRINKLER:WEATHERMATIC MAX6PRS40-CV W/HUNTER MP2000 NOZZLES I FOR HAVE COMPE LIED WITH USE THE F CRITERIATOF IRRIGATION THE WATER EFFICIENT DESIGN PLAN NOTES LANDSCAPINGSTANDARDS AND APPLIED THEM ACCORDINGLY NOTES PRESSURE:40 PSI RADIUS:13 FEET TO 21 FEET FLOW(GPM):K-0.77 G-1.10 R-1.48 QQQ POP-UP ROTATING SPRAY SPRINKLER:WEATHERMATIC MAX6PRS40-CV W/HUNTER MP3000 NOZZLES ktik e PRESSURE:40 PSI RADIUS:22 FEET TO30FEET Hines Inc FLOW(GPM):B-1.82 Y-2.73 A-3.64 I R 10 0 OS/22/2019 SITE WATER ENGINEERING SERVICES EDWARD W PRICE,CID,CLIA DATE 323 W.DRAKE RD,SUITE 204 ID#:50322 FORT COLLINS,COLORADO 80526 Telephone:970.282.1800 RECEIVED Web:www.hinesinc.com 06/17/2019 ASPEN BUILDING DEPARTMENT N IRRIGATION LEGEND A .. SLEEVES:CLASS 200 PVC ceP- • 0 1-POINT-OF-CONNECTION ASSEMBLY U _ MAINLINE PIPE:CLASS 200 PVC z o O ' .� 1 1/4-INCH SIZE UNLESS OTHERWISE INDICATED N w .. O O LATERAL PIPE TO SPRINKLERS:CLASS 200 PVC IL• m E / ''''''' °j ,' 1-INCH SIZE UNLESS OTHERWISE INDICATED I—Q 0, .7, m ............. LATERAL PIPE TO DRIP EMITTERS:UV RADIATION RESISTANT POLYETHYLENE U _ ] 3/4-INCH SIZE UNLESS OTHERWISE INDICATED,ROUTING IS DIAGRAMMATIC O m O FA- N ISOLATION GATE VALVE ASSEMBLY:MATCO 514 ca1 i. m QUICK COUPLING VALVE ASSEMBLY:RAIN BIRD 5RC .............. ..... .... ......... i Q 3 m 3 ' n O m E M tlj." � - o ,,,,,,,,,,,,,,,,, ,, ,,,,,,,,,,, Q REMOTE CONTROL VALVE ASSEMBLY FOR SPRINKLE LATERALS: © A __ WEATHERMATIC MAX-DW SERIES(SIZED PER PLAN) °' �+ All landscaped and irrigated - - ¢J m r� • "a � ?� °' i " •� - - ® REMOTE CONTROL DRIP VALVE ASSEMBLY:RAIN BIRD XCZ PRB-100-COM U c g j O ........................ - t the entire property(including theaillIllt '° n:° ,P,- _ - _ 0 r m ROW)should.be on the plans --- ` d.° - • 49:+` FLUSH CAP ASSEMBLY ¢o z', I ....... ..... /gr i / r c c `j\and In the weep buget A5 1 jatd tlDpS. ,,,,, _ UNCONNECTED PIPE CROSSING - - 9 Dn a(JD - 1. ri//iA r -- -- . Shrub .. - . ! n--+..F A4 m ipt ��INDICATES LATERAL DISCHARGE(GPM)NUMBER ( e ..- , h�., `> `•`✓ 8A0 ® �� INDICATES VALVE SIZE(INCHES) O - T 1 Mi �� INDICATES LANDSCAPE APPLICATION OR APPLICATION RATE(IN/HR) f=, a i/,\ _; a ,,a; as i, 30��INDICATES DESIGN PRESSURE(PSI) KIN COUNTY ..... .... ... ]7 „„ h, A3 ....... .'. ,,,, ° S 4 a �: O e •POP-UP SPRAY SPRINKLER:WEATHERMATIC MAX6PRS30-CV W/RAIN BIRD U-SERIES NOZZLES ® 1Turf PRESSURE:30 PSI RADIUS: FEET COURTHOUSE _. ..._._ �_� rv� :. . . . .!:: :..v..... ..:. ,n I FLOW(GPM):Q-0.26 H-0.52 F-1.05 STE.300 ... • ADDRESS: s aS ASPEN 506 E. MAIN ./ \ _ . �n?. 0 E •POP-UP SPRAY SPRINKLER:WEATHERMATIC MAX6PRS30-CV W/RAIN BIRD U-SERIES NOZZLES i 81611 O • ET "'8' \� // I FLOW(GPM):Q O• PRESSURE:30 I41 RAHIO 820 FE1 64 PARCEL# Shrub I 27370734347851 " A L •POP-UP SPRAY SPRINKLER:WEATHERMATIC MAX6PRS30-CV W/RAIN BIRD U-SERIES NOZZLES ''''' : m PRESSURE:30 PSI RADIUS:12 FEET ® FLOW(GPM):Q-0.65 H-1.30 F-2.60 DATE: •_ • 0 2019.05.10 'i it A L ° . ® o e •POP-UP SPRAY SPRINKLER:WEATHERMATIC MAX6PRS30-CV W/RAIN BIRD U-SERIES NOZZLES `� i / I PRESSURE:30 PSI RADIUS:15 FEET ISSUE: C`._�``'F. m" �,a • FLOW(GPM):Q-0.92 H-1,85 F-3.70 FOR PLANNING s. y PURPOSES ONLY �� _ '. i i 0©®POP-UP ROTATING SPRAY SPRINKLER:WEATHERMATIC MAX6PRS40-CV W/HUNTER MP2000 NOZZLES (NOT FOR CONSTRUCTION) ir ...,r i,- a. PRESSURE:40 PSI RADIUS:13 FEET TO 21 FEET ill �� • e v n FLOW(GPM):K-0.77 G-1.10 R-1.48 DRAWN BY:BI CHECKED BY:MR r•� O QQQ POP-UP ROTATING SPRAY SPRINKLER:WEATHERMATIC MAX6PRS40-CV W/HUNTER MP3000 NOZZLES `� -__.afiII WELS Section 5.1 requires PRESSURE:40 PSI RADIUS:22 FEET TO 30 FEET // / backflow prevention FLOW(GPM):B-1.82 Y-2.73 A-3.64 // / devices,manual shutoff HISTORY: // valves,smart irrigation // / controllers,flow sensors, DATE ISSUE IiiI1t ` moisture sensors,main and zole.os.zz 1O se,etc.Revise plans and calculations to NEN. W address all requirements of the WELS for the entire . •.erty. CONSTRUCTION NOTES ` U THEIRRIGATION SYSTEM POINT-OF-CONNECTION(POC)SHALL BE 41141 v DOWNSTREAM OF THE EXISTING 1 1/4-INCH IRRIGATION MAINLINE AND CONTROL WIRE PATH AT THE APPROXIMATE LOCATION SHOWN.MAKE NEW CONNECTION AND ROUTE NEW MAINLINE AS SHOWN.VERIFY EXACT O LOCATION OF POC WITH OWNER'S REPRESENTATIVE. 11-11-1 O CONTRACTOR SHALL MAKE REPAIRS AND MAINTAIN EXISTING IRRIGATION EQUIPMENT IN THIS APPROXIMATE LOCATION. fir0 ), I/i IRRIGATION PIPE SCHEDULE CLASS 200 PVC PIPE i SIZE FLOW _ 1-INCH 0-15 1.25-INCH 16-25(GPM) 1.5-INCH 26-35 2-INCH 36-55 .MPo�oo�.. *lab 2.5-INCH56-80 r 3-INCH 81-11041NCH 111-200 , /////f' IF THERE IS A DISCREPANCY BETWEEN PIPE SIZES SHOWN ON THE prnu/ / ` / DRAWINGS AND THIS PIPE SCHEDULE,TT IS THE RESPONSIBILITY OF „�,m.sumps 0 \ / THE CONTRACTOR TO CONTACT THE IRRIGATION DESIGNER FOR \ / I CLARIFICATION. SHEET TITLE: -Ij-)- 0' 4' 8' 16' 32' NORTH SCALE:t"=3'-D" IRRIGATION PLAN 4 Hines Inc SITE WATER ENGINEERING SERVICES 1 R-2 0 0 323 W.DRAKE RD,SUITE 204 FORT COLLINS,COLORADO 80526 Telephone:970.282.1800 RECEIVED Web:www.hinesinc.com 06/17/2019 ASPEN BUILDING DEPARTMENT N V1 cn c cm 01 Z G -0 rm- cr)w ...• W 2 '- • - B U-E E O m 7.2 'o, , m u7 . U H ¢m m' 3 =2 a O m„ a "w FINISH GRADE VALVE BOX WITH COVER: -2` rn c CARSON 910-4. 30-INCH LINEAR LENGTH OF WIRE, U c g c ��, BRAND LID WITH VALVE "QC" COILED SPRAY NOZZLE, PER PLAN: '`�; VALVE BOX WITH COVER: 3-INCH MAX SEE LEGEND FOR MODEL o 2-INCH MIN CARSON 910-4. FINISH GRADE WATER PROOF CONNECTION (1 OF 2) I ¢a N BRAND LID WITH VALVE "IGV" V ,•� 1i1��`<�,6111,1 — 1�Ilii���iillti�0.��!�ii�ill��►1a FINISH GRADE/TOP OF MULCH cn▪ - a.' �,,N QUICK COUPLING VALVE PER LEGEND VALVE BOX WITH COVER: CARSON 'IlH ill . STAINLESS STEEL HOSE CLAMP 1419-4. BRAND LID WITH VALVE NUMBER � II II�������II I --d, ri///A 4-INCH PVC CL 200 PIPE (1 OF 2) REMOTE CONTROL VALVE, SIZED AS (LENGTH AS REQUIRED) �t 1 SHOWN ON DRAWINGS POP-UP SPRAY BODY: ••+ •Ooo�o' 36-INCH No. 6 EPDXY COATED REBAR WITH CHECK VALVE AND PRESSURE ( 1, FINISH GRADE TOP OF MULCH '00�` - I / REGULATING VALVE FEATURES O°,° 3-INCH MINIMUM DEPTH OF = o 00 3-INCH DEPTH OF 3/4-INCH WASHED SECURE CHRISTY ID TAG WITH NYLON 3/4-INCH WASHED GRAVEL ��� / SEE LEGEND FOR MODEL / 1 GRAVEL 3" MIN. ZIP TIE. LABEL WITH CONTROLLER AND � o°o o r.'g�000�00°1� BRICK (1 OF 2) STATION NUMBER. PITKIN COUNTY BRICK (1 OF 2) °o°°° oo°ate• o ,. o° �/ -SCH 8D PVC NIPPLE, TOE 1/2-INCH MALE NPT x .490 INCH (LENGTH VARIES) SPEARS PVC TRUE UNION BALL VALVE BARB ELBOW: RAIN BIRD MODEL COURTHOUSE GATE VALVE WITH CROSS HANDLE, PRE-FABRICATED SWING JOINT: PVC SCH 40 EL \MINI SBE-050 ADDRESS: rl SIZED TO MATCH MAINLINE. MODEL .,_ SPEARS 5815-010-10 /—BRICK (1 OF 4) �, 506 E. MAIN ST.STE.300 PER LEGEND o oo�o �0000000 0o ASPEN,CO 81611 PVC MAINLINE PIPE �„°0 soo °o PVC SCH eo PIPE ' =� PVC LATERAL PIPE PARCEL# •/, (LENGTH AS REQUIRED) MO IIS PVC MAINLINE b U PVC MAINLINE 27370734347851 NMI SCH 40 PVC TEE OR EL WITH FPT OUTLET PVC SCH. 40 MALE ADAPTER PVC SCH 4D TEE OR EL PVC SCH. 40 TEE OR EL DATE: (SPEARS 436 SERIES) SWING PIPE, 12-INCH LENGTH: 2019.05.10 PVC SCH 40 MALE ADAPTER RAIN BIRD SPS-FLEX100 NOTES: (SPEARS SR-2-0801) ISSUE: 1. NOMINAL SIZE OF GATE VALVE TO MATCH NOMINAL MAINLINE SIZE. 3.0-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL FOR PLANNING PURPOSES ONLY (NOT FOR CONSTRUCTION) 4111 ISOLATION GATE ©QUICK COUPLING © REMOTE CONTROL TURF 6-INCH POP UP SPRAY DRAWN BY:BI CHECKED BY:MR VALVE ASSEMBLY VALVE ASSEMBLY VALVE ASSEMBLY 4 SPRINKLER ASSEMBLY SECURE CHRISTY ID TAG WITH NYLON HISTORY: ZIP TIE. LABEL WITH CONTROLLER AND STATION NUMBER. DATE ISSUE VALVE BOX WITH COVER: CARSON 2019.05.22 MP ROTATOR NOZZLE, PER PLAN ' 419-4. BRAND1 LID WITH VALVE NUMBER DIFFUSER BUG CAP: VALVE BOX WITH COVER: CARSON 708-4. f FINISH GRADE/TOP OF MULCH FINISH GRADE/TOP OF MULCH RAIN BIRD MODEL DBC-025 BRAND LID WITH "FC" �I� II I�I II II � III I�i I- WATER PROOF CONNECTION (1 OF 2) 1/4-INCH TUBING STAKE, 1 RAIN BIRD #TS-025 30-INCH LINEAR LENGTH OF WIRE, yy�yti y-y�y FINISH GRADE/TOP OF MULCH I POP-UP SPRAY BODY: V 3 M'� �� COILED 1/4-INCH DISTRIBUTION TUBING " � LI ?I� WITH CHECK VALVE AND PRESSURE nj�� • _ _ REMOTE CONTROL VALVE, SIZED AS �� REGULATING FEATURES • > SHOWN ON DRAWINGS MULCH BED �` � FLUSH CAP: 3/4-INCH BARBED OR (SEE NOTE 2 BELOW) �,�rI a_ . SPEARS PVC TRUE UNION BALL VALVE COMPRESSION FITTING WITH '_. II INAI"IIO� DRIP EMITTER THREADED CAP APPROVED GEOTECH FILTER FABRIC/ i o 0 �0 1 ,o°°o° kMI (EXTEND 10" UP BOX WALL) ) (REFER TO SPECIFICATIONS) 1LBOINCH MALE NPT x .490 INCH BARB o�oo.'o oo��,i io�o� r► PVC SCH 80 PIPE (LENGTH AS /// / / / 3/4-INCH DRIP LATERAL PIPE (MIN ELBOW: RAIN BIRD MODEL SBE-050 2"" /I`1 / / / 12 INCHES LOOPED) .—�—� REQUIRED) /////// / ///// / 3 INCH DEPTH OF 3/4-INCH PVC MAINLINE �//� / ///�a �� IWASHED GRAVEL a\ BRICK (1 OF 4) /// /,% � /, �� ��.��. �� �� �� �� ��_ �� FINSH GRADE 3/4-INCH MALE BARBED ELBOW Pvc ATERAL PIPE Pvc scH 4o TEE oR EL %///////// ///j//j//j//j/////j/// 000�ci,...6, ono•o-000 11LOOP 1' OF 2 SPARE WIRES \ \ \ \ \ \ V 'OYA���A,YA \i�A i�A i�A i�A,� V� $° ° :_:°°O��'�-°aoo m ° BRICK (1 OF 2) COMBINED PRESSURE REGULATOR .iii -' ° PVC SCH. 40 TEE OR EL AND Y-STRAINER 3.0-INCH MINIMUM DEPTH OF DRIP LATERAL PIPE �p 3/4-INCH DRIP LATERAL PIPE SWING PIPE, 12-INCH LENGTH: 3/4-INCH WASHED GRAVEL PLANT ROOT BALL RAIN BIRD SPX-FLEX100 NOTE: NOTES: 1. USE BARBED INSERT FITTINGS ON DRIP LATERAL PIPE WITH STAINLESS STEEL HOSE 1. IF POLYETHYLENE PIPE IS USED FOR LATERAL PIPE, SUBSTITUTE INSERT TEE OR EL WITH STAINLESS CLAMPS. PLACE CLAMPS ON DRIP TUBING DIRECTLY OVER BARBED AREA OF FITTING. NOTE: STEEL CLAMPS FOR PVC SLIP TEE OR EL SHOWN ABOVE. PINCH CLAMPS ARE NOT ACCEPTABLE. 1. LOOP IRRIGATION DRIP TUBING INSIDE VALVE BOX FOR EXTENSION OUTSIDE OF 2.TO ACHIEVE MINIMUM RADIUS WITH ANY MP ROTATOR MODEL, USE HUNTER PRS30 BODY BOX DURING BLOWOUT. O6-INCH POP UP 6 REMOTE CONTROL DRIP O SINGLE OUTLET DRIP DRIP FLUSH CAP MP-ROTATOR ASSEMBLY VALVE ASSEMBLY EMITTER ASSEMBLY 8 ASSEMBLY SHEET TITLE: IRRIGATION DETAILS A-, Hines Inc SITE WATER G S323 W.DRAKE RD,SUIT12 ERVICES I �� 0 0 FORT COLLINS,COLORADO 80526 Telephone:970.282.1800 RECEIVED Web:www.hinesinc.com 06/17/2019 ASPEN BUILDING DEPARTMENT 0 N V1 W U Z G -0 Cnw ..., W 2 I- . ZZ o U-c O% 72 'o, ,R R u7 . U H Q m m' 3 Z w '---TYPICAL RAIN/FREEZE/WIND SENSOR; O m a E I,;_.� PROPERLY MOUNTED ON POST OR PROFILE VIEW PLAN VIEW <r,= _ GUTTER TO RECEIVE FULL SUN, OPEN IRRIGATION CONTROLLER. PLANT TYPE BY EMITTERS GPH PER TOTAL GPH TO RAINFALL AND OUT OF SPRINKLER #6AWG SOLID BARE COPPER WIRE #6AWG SOLID BARE COPPER WIRE 2 m m c HYDROZONE PER PLANT EMITTER PER PLANT COVERAGE. 4" x 96" x V' I g !;t 2" MINWALL MOUNTED CONTROLLER COPPER GROUNDG PLATE / m¢a 00 I� CLAMP 3L CONDUIT; MAX WIRE DISTANCE: 200'. CONNECTION K �� 3W u7-° a �WALL � 30" MIN -,� /� W - 5ri//iA MED WATER USE TREE 4 SINGLE 1 GPH 4 GPH I� (WIRELESS OPTIONAL; REFER TO LEGEND) } T \\f �'� ..J •.' 120 VOLT POWER SUPPLY WIRES IN o HIGH WATER USE TREE 3 SINGLE 2 GPH 6 GPH - Ii METAL CONDUIT L LOW WATER USE SHRUBS 1 SINGLE 1 GPH 1 GPH MINIMUM 10 FT.-� Ilia. PVC CONDUIT FOR CONTROL WIRES II �I L TO LANDSCAPED AREA 3L MED WATER USE SHRUBS 2 SINGLE 1 GPH & 0.5 GPH 1.5 GPH PVC SWEEP ELL #6 BARE COPPER GROUNDING WIRE IN �� 4" X 6" X Y,s" 1.5 SIZE - I, METAL CONDUIT 2L I COPP R GROUND PLATE PITKIN COUNTY HIGH WATER USE SHRUBS 2 SINGLE 1 GPH 2 GPH „ ��/,),: �_11 PAVEMENT A ' 2 ) COURTHOUSE 1111111111 '�®_ FINISH GRADE \ \ \ ADDRESS: LOW WATER USE PERENNIAL 1 SINGLE 1 GPH 1 GPH II III.IIIIII111=III=111 L 1,,._; 1. - - .I- _ PVC SWEEP ELL 506 E. MAIN ST.STE.300 ��� "G• DIRECT BURIAL CONTROL WIRES TO ---#6AWG SOLID BARE COPPER WIRE ASPEN,CO 81611 MED WATER USE PERENNIAL 2 SINGLE 1 GPH & 0.5 GPH 1.5 GPH ' #6AWG SOLID COPPER BARE WIRE CONTROL VALVES \ MI5 5/8"x10' GROUNDING Roo. PARCEL# HIGH WATER USE PERENNIAL 2 SINGLE 1 GPH 2 GPH COPPER GROUNDING WIRE C ELECTRODE SPHERE OF INFLUENCE To BRONZE CLAMP. 27370734347851 COPPER CLAD GROUND ROD (5/NOTEs: PART NUMBER 1820" X 8') PAIGE 007ECTRIC " DATE: 1. ALL EMISSION POINTS TO BE LOCATED ON THE UPHILL SIDE OF PLANT NOTES. NOTES � 2019.05.10 MATERIAL. 1. INSTALL ALL WIRING PER LOCAL ELECTRICAL CODES. 1. INSTALL GROUNDING ROD OR PLATE BASED ON SITE CONDITIONS, DO NOT INSTALL BOTH. 2. ALL EMITTER QUANTITIES AND FLOW RATES ARE FOR RECOMMENDATION ONLY. 2. INSTALL GROUND ROD WITHIN IRRIGATED TURF AREA. IF IRRIGATED TURF AREA IS NOT IN 2. DO NOT INSTALL ANY OTHER WIRE OR CABLES INSIDE THE SPHERE OF INFLUENCE. ISSUE: THE CONTRACTOR SHALL CONSULT AND CONFIRM WITH LOCAL PRACTICE PRIOR CLOSE PROXIMITY TO CONTROLLER, INSTALL ONE (1) DRIP EMITTER FROM NEAREST DRIP 3. INSTALL GROUNDING PLATE AT A MINIMUM OF 30-INCHES BELOW GRADE OR BELOW FROST-LINE, WHICHEVER IS DEEPER. FOR PLANNING TO INSTALLATION. VALVE IN VALVE BOX HOUSING GROUNDING ROD. 4. TYPICAL INSTALLATION SHOWN FOR AN IRRIGATION CONTROLLER CAPACITY OF 64 STATIONS OR LESS, INSTALL AN ADDITIONAL GROUNDING ROD/PLATE PER 64 STATIONS. PURPOSES ONLY (NOT FOR CONSTRUCTION) 9 1 EMITTER SCHEDULE WALL MOUNT TYPICAL IRRIGATION CONTROLLER GROUNDING DRAWN BY:BI CHECKED BY:MR CONTROLLER ASSEMBLY ROD OR PLATE INSTALLATION CHRISTY ID TAG HISTORY: PAVED SURFACE MAINLINE, LATERAL, PIPE AND WIRE FINISHED GRADE DATE ISSUE & 24—V WIRE LATERAL PIPE SLEEVING CURB AND GUTTER IF APPLICABLE 3" MIN 1 2019.05.22 IRRIGATION CONTROL WIRES SECURED FINISH GRADE CONCRETE SLAB TO BOX WITH NYLON ZIP TIE. 36" IRRIGATION VALVE/SENSOR ASSEMBLY y 12" MIN (ABOVE GRAVEL) 3.0-INCH MINIMUM DEPTH OF r ROUGH GRADE 18" � 3/4-INCH WASHED GRAVEL III III= ���� °o °� o P' o�b 24" III III 2 PVC PIPE SLEEVE MARKER: INSTALL AT °O° °°'O...;Ps BRICK (1 OF 4) a a III III III BOTH ENDS OF EACH SLEEVE LOCATION AND APPROVED GEOTECH FILTER FABRIC 24" III III III EXTEND AT LEAST 3 ABOVE GRADE. SPRAY • O 4 1IIITIII r (EXTEND 10' Up Box WALL) Ai_ _ — EXPOSED PORTION OF MARKER WITH GREEN � • III 1III III= FLUORESCENT PAINT. STANDARD QUICK 4 24-INCH MIN ® i COUPLER OR ISOLATION ® 1 GATE VALVE BOX J co • T1 b WA 4''-6” MIN. EXCAVATED MATERIAL S MIN. MIN 12' �� STANDARD CARBON 1419 PIPE WIRING MIN 12' REMOTE CONTROL VALVE BEDDING & COVER MATERIAL SLEEVE SLEEVE MIN 12" BOX SEAL ENDS OF SLEEVES WITH CLOTH TURF OR PLANTING BED — WARNING TAPE DUCT TAPE (TYPICAL) +.. NOTES: PVC SLEEVING (TYPICAL) � a . '-""---4---- m a PAVEMENT OR EDGING RESTRAINT 1. SLEEVE ALL PIPE AND WIRE SEPARATELY. NOTES ., 2. ALL PIPE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS."SNAKE" UNSLEEVED NOTE: 1. INSTALL ONLY ONE RCV TO VALVE BOX. LOCATE AT LEAST 12-INCHES FROM PLASTIC PIPE IN TRENCH. PROVIDE A MINIMUM OF 2" CLEARANCE TO SIDE OF TRENCH 1) ALL SLEEVING TO BE CLASS 200 BE PVC, SIZED AS NOTED. AND ALIGN WITH NEARBY WALLS OR EDGES OF PAVED AREAS. GROUP RCV AND BETWEEN PIPES. 2) INSTALL SLEEVES IN SIDE-BY-SIDE CONFIGURATION WHERE MULTIPLE SLEEVES ASSEMBLIES TOGETHER WHERE PRACTICAL. 3. ALL 120-V WIRING SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL CODE ARE TO BE INSTALLED. SPACE SLEEVES 4" TO 6" APART. DO NOT STACK SLEEVES 4. GROUP RCV ASSEMBLIES TOGETHER WHERE PRACTICAL, BUT AVOID GROUPING REQUIREMENTS. TAPE AND BUNDLE 24-V WIRE EVERY 10' AND PROVIDE LOOSE 20" LOOP VERTICALLY. MORE THAN THREE (3) STANDARD VALVE BOXES TOGETHER IN A SERIES. AT ALL CHANGES OF DIRECTION OVER 30 DEGREES. 5. ARRANGE GROUPED VALVE BOXES IN RECTANGULAR PATTERNS. n,,,,,'O6o�,,,, 4E4 TYPICAL TRENCHING ®TYPICAL SLEEVING TYPICAL VALVE BOX DETAIL DETAIL 14 INSTALLATION SHEET TITLE: IRRIGATION DETAILS A-,.._ Hines Inc SITE WATER ENGINEERING SERVICES 1 R.3 O 1 323 W.DRAKE RD,SUITE 204 FORT COLLINS,COLORADO 80526 Telephone:970.282.1800 RECEIVED Web:www.hinesinc.com 06/17/2019 ASPEN BUILDING DEPARTMENT