Loading...
HomeMy WebLinkAboutFile Documents.541 Race St.0197.2019.ARBKISSUE: 98% SD HPC: 11.30.2015, 4.27.16, 12.8.16 PROGRESS: 5.16.16, 6.12.16, 6.23.16 11.2.16 HPC final: 3/1/17 PERMIT: 3.22.17 CONSTRUCTION: PROJECT # 1403 FILENAME: 1403 ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO 81611 CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE STRUCTURAL DESIGN 1040 MAIN ST CARBONDALE, CO 81623 CONTACT: SARA MICKUS (V) 970.510-0773 SURVEYOR HIRED GUN SURVEYING P.O. BOX 9 SNOWMASS, CO 81654 CONTACT: TOM YOKUM (V) (970) 923-2794 LANDSCAPE ARCHITECT LIFT STUDIO PO BOX 2748 ASPEN, CO 81612 CONTACT: RYAN VUGTEVEEN (V) (970) 404 5610 CIVIL ENGINEER WOODY CREEK ENGINEERING,LLC 520 E. HYMAN AVE. #201 ASPEN, CO 81612 CONTACT: JOSH RICE (V) 970 309 7130 SOILS ENGINEER CHURCH AND ASSOCIATES, INC 4501 WADSWORTH BLVD WHEATRIDGE, CO 80033 (V) 303 463 9317 MECHANICAL CONSULTANT DESIGN-BUILD BY GC GENERAL CONTRACTOR TBD. FOX CROSSING PROPERTIES LOTS 4&6 LLC 6330 MERCER STREET HOUSTON, TEXAS 77005 CONTACT: JOHN MORTON VC: 713 299 7674 ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO 81611 CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE STRUCTURAL DESIGN 1040 MAIN ST CARBONDALE, CO 81623 CONTACT: SARA MICKUS (V) 970.510-0773 SURVEYOR HIRED GUN SURVEYING P.O. BOX 9 SNOWMASS, CO 81654 CONTACT: TOM YOKUM (V) (970) 923-2794 LANDSCAPE ARCHITECT LIFT STUDIO PO BOX 2748 ASPEN, CO 81612 CONTACT: RYAN VUGTEVEEN (V) (970) 404 5610 CIVIL ENGINEER WOODY CREEK ENGINEERING,LLC 520 E. HYMAN AVE. #201 ASPEN, CO 81612 CONTACT: JOSH RICE (V) 970 309 7130 SOILS ENGINEER CHURCH AND ASSOCIATES, INC 4501 WADSWORTH BLVD WHEATRIDGE, CO 80033 (V) 303 463 9317 MECHANICAL CONSULTANT DESIGN-BUILD BY GC GENERAL CONTRACTOR TBD. A100   , 4.12.18 Residence 541 Race Street Aspen, Colorado Temporary Micropile Wall* BY-1. Temporary Micropile Wall - Cover BY-2. Temporary Micropile Wall - Location BY-3. Temporary Micropile Wall - Profile BY-4. Temporary Micropile Wall - General Notes BY-5. Temporary Micropile Wall - Sections BY-6. Temporary Micropile Wall - Typical Sections and Details * These plans and specifications are designed to provide temporary excavation support with a finite design life during construction operations. Long-term earth pressure loads shall be included in the structural design. Temporary Micropile Wall Cover June 27, 2016 Residence 541 Race Street 266 Red Cliff Circle Glenwood Springs, CO 81601 Phone: (970) 230-9208 16-024G-D1 BY-1 of 6 RDJ Project Number: Date:Sheet Number:Prepared by:Project: Set Revisions Date Revision/Issue Prepared by B&Y Drilling, Inc. Designed For:Seal: Proposed Micropile Cap Location Micropile Wall Start/End Wall Micropile Wall Turn Line 1 Micropile Wall Turn Line 2 Micropile Wall Turn Line 3 Micropile Wall Turn Line 4 Micropile Wall Turn Line 5 Micropile Wall Turn Line 6 Micropile Wall Turn Line 7 0+ 2 0 BY - 5 1+10 BY-5 1+ 7 0 BY - 5 2+20 BY-5 Truncate back of cap at property line 0+ 2 0 0+40 0+60 0+ 8 0 1+00 1 + 2 0 1 + 4 0 1+ 6 0 1+ 8 0 2+00 2+40 Heavy loads shall not be placed between micropile cap and this line (Sheet BY-4, Note 3.4) Heavy loads shall not be placed between micropile cap and this line (Sheet BY-4, Note 3.4) Temporary Micropile Wall Location June 27, 2016 Residence 541 Race Street 16-024G-D1 BY-2 of 6 RDJ Project Number: Date:Sheet Number:Prepared by:Project: Sheet Revisions Date Revision/Issue Prepared by B&Y Drilling, Inc. Designed For:Seal: N SCALE: 1" = 5' 5 0 2.5 5 Notes: 1. Base plan by Willis Pember Architects dated 6-23-16. 2. Micropile wall shall be constructed entirely within property boundaries. 3. This drawing should not be used for foundation wall layout. 266 Red Cliff Circle Glenwood Springs, CO 81601 Phone: (970) 230-9208 7940 7950 7930 7920 7910 El e v a t i o n ( f e e t ) 0+ 0 0 . 0 S t a r t / E n d W a l l Sy s t e m 1 EG = 7 9 3 2 . 0 TO W = 7 9 3 2 . 0 BO E = 7 9 2 0 . 0 0+ 5 0 1+ 0 0 7960 7940 7950 7930 7920 7910 El e v a t i o n ( f e e t ) 7960 0+ 3 2 . 7 T u r n L i n e 1 Ch a n g e S y s t e m 1 t o 2 EG = 7 9 3 4 . 0 St e p T O W = 7 9 3 4 . 0 t o 7 9 3 2 . 0 BO E = 7 9 2 0 . 0 Existing Grade Micropile Wall Cap 1+ 5 0 Bottom of Excavation (BOE) 0+ 7 0 . 3 T u r n L i n e 3 Sy s t e m 2 EG = 7 9 3 5 . 0 TO W = 7 9 3 3 . 0 St e p B O E = 7 9 2 0 . 0 t o 7 9 2 5 . 0 2+ 0 0 Temporary Slope at 1.5H:1V 2+ 5 0 Temporary Slope at 1.5H:1V 0+ 5 4 . 3 T u r n L i n e 2 Sy s t e m 2 EG = 7 9 3 4 . 6 TO W = 7 9 3 2 . 6 BO E = 7 9 2 0 . 0 0+ 8 9 . 2 T u r n L i n e 4 Ch a n g e S y s t e m 2 t o 1 EG = 7 9 3 7 . 0 St e p T O W = 7 9 3 5 . 0 t o 7 9 3 7 . 0 BO E = 7 9 2 5 . 0 1+ 1 7 . 6 T u r n L i n e 5 Sy s t e m 1 EG = 7 9 3 8 . 0 TO W = 7 9 3 8 . 0 BO E = 7 9 2 5 . 0 1+ 4 7 . 0 T u r n L i n e 6 Sy s t e m 1 EG = 7 9 3 5 . 0 TO W = 7 9 3 5 . 0 St e p B O E = 7 9 2 5 . 0 t o 7 9 2 0 . 0 1+ 8 3 . 0 T u r n L i n e 7 Ch a n g e S y s t e m 1 t o 2 EG = 7 9 3 4 . 0 St e p T O W = 7 9 3 4 . 0 t o 7 9 3 2 . 0 BO E = 7 9 2 0 . 0 2+ 5 0 . 8 E n d / S t a r t W a l l Sy s t e m 2 EG = 7 9 3 2 . 0 TO W = 7 9 3 0 . 0 BO E = 7 9 2 0 . 0 Existing Grade Temporary Micropile Wall Profile June 27, 2016 Residence 541 Race Street 16-024G-D1 BY-3 of 6 RDJ Project Number: Date:Sheet Number:Prepared by:Project: Sheet Revisions Date Revision/Issue Prepared by B&Y Drilling, Inc. Designed For:Seal: 266 Red Cliff Circle Glenwood Springs, CO 81601 Phone: (970) 230-9208 SCALE: HORIZONTAL 1" = 10' VERTICAL 1" = 10' ABBREVIATIONS: EG - Existing Grade TOW - Top of Wall BOE - Bottom of Excavation 1.0 Temporary Micropile Wall Materials 1.1 Micropile bars - Williams 38 Injection Bars (Vertical Micropiles) for Systems 1 and 2 Williams 32 Injection Bars (Battered Micropiles) for System 2 fy=85,000 psi 1.2 Grout - Grout may be neat-cement or with sand, with Type II cement in accordance with ASTM C150. Water-cement ratio should be between 0.4 and 0.6. f'c=3,000 psi (28-day strength) 1.3 End hardware - Nuts shall be in accordance with manufacturer's recommendations. Bearing plate shall be in accordance with ASTM A36, Grade 36. 1.4 Concrete - Concrete mix shall consist of Type II cement in accordance with ASTM C150, potable water and normal weight aggregate in accordance with ASTM C33. Air entrainment is not required. Admixtures, if used, should be non-corrosive to steel. f'c=3,000 psi (28-day strength) 1.5 Cap reinforcement shall be in accordance with ASTM A615. fy=60,000 psi 2.0 Micropile Wall Construction Sequence 2.1 Install micropiles at the locations and to the lengths shown on the plans. Micropile injection bars shall be installed per manufacturers recommendations. Micropile locations may vary by up to 3". 2.2 Install end hardware and reinforcing bars as shown on the drawings. 2.3 Pour concrete cap to the minimum thickness shown on the drawings and to attain the minimum coverages specified herein. Cold weather protection measures may be necessary. 2.4 After concrete and grout has attained 80% of specified strength, complete excavation to full depth of wall not to exceed maximum wall heights as shown on the drawings. Excavation shall extend to grout/micropile columns (cap may be undermined). Soil should not be left between excavation face and grout/micropile columns. 3.0 Temporary Micropile Wall Design Parameters 3.1 The micropile shoring was designed in general accordance with procedures contained in the FHWA "Micropile Design and Construction Reference Manual", Publication No. FHWA NHI-05-039, December 2005. 3.2 The following strength parameters were assumed for the subsoils based on the "Soils and Foundation Investigation, Fox Crossing Development, Gibson Avenue & Lone Pine Street, Aspen, Colorado" by Church & Associates, Inc., Project No. CO51128, report dated September 6, 2005. The following values were assumed for soil design parameters: φ γ (deg) (psf) (pcf) Sand and Gravel 36 100 130 An experienced geotechnical engineer should verify the above design parameters during construction. 3.3 Global Factor of Safety = 1.3 min. 3.4 The excavation shoring systems are designed to accommodate normal construction surcharge of material and light trucks, not heavy loads such as cranes (wheels or outriggers), concrete trucks, concrete pumpers (wheels or outriggers) or large stockpiles. Heavy loads shall not be placed within areas designated on Sheet BY-2. 3.5 No groundwater table was assumed. If groundwater is encountered during excavation, the excavation shall not continue and the site shall be dewatered to below the base of planned excavation elevation prior to completion of the excavation. 3.6 The micropile walls lateral deflection may range from 0 to 2 inches. The design calculations show there will be no adverse deflection of the ground surface at the property line based on anticipated subsurface conditions. 3.7 There will be no adverse effects including potential deflection on any adjacent properties based on anticipated subsurface conditions. 4.0 Special Provisions 4.1 Wall geometry used in design was based on plans provided by Willis Pember Architects plans dated 06-23-16. 4.2 This design is valid only for B&Y Drilling, Inc. at the subject site. 4.3 Excavation shall extend to micropile columns. During the excavation process, material should not be left between the excavation face and the grout/micropile column. 4.4 The micropile wall designs are valid only for dry surface and subsurface conditions. If surface water or groundwater is encountered during excavation or installation, RJ Engineering should be notified immediately and the wall may be redesigned at the discretion of RJ Engineering. Surface and subsurface drainage from adjacent properties should not be discharged at the top or through the micropile wall. Saturated soils may result in materials piping out from between micropiles resulting in failure and/or excessive wall movements. 4.5 The design life on this micropile wall is 12 weeks. Design life is defined by the beginning of excavation to backfill completion of the foundation wall. If the duration of the project exceeds the 12 week duration, RJ Engineering shall be contacted to evaluate the performance of the system and determine if the design life can be extended. 4.6 RJ Engineering is not responsible for maintaining slope stability above and below the micropile wall during construction. 4.7 There appears to be no known utility conflicts with installation of the micropile walls. Utility locations presented shall be field verified prior to micropile wall installation. 4.8 RJ Engineering is not responsible for quality control, quality assurance, changed conditions or problems resulting from improper construction techniques. 4.9 RJ Engineering is not responsible for construction site safety. 4.10 RJ Engineering is not responsible for wall layout. General contractor or representative of the general contractor is responsible for micropile wall layout. 4.11 Observation of micropile wall installation should be performed by a qualified engineer. Inspection and/or monitoring of the micropile wall after completion of excavation should be performed. The frequency and duration of the observation and monitoring shall be determined by the qualified engineer. The qualified engineer shall have experience with design and installation of micropile wall systems using injection bars. Observations shall be made at least on a weekly basis during installation and during the service life of the system. Temporary Micropile Wall General Notes June 27, 2016 Residence 541 Race Street 16-024G-D1 BY-4 of 6 RDJ Project Number: Date:Sheet Number:Prepared by:Project: Sheet Revisions Date Revision/Issue Prepared by B&Y Drilling, Inc. Designed For:Seal: 266 Red Cliff Circle Glenwood Springs, CO 81601 Phone: (970) 230-9208 NORTH SIDE Station 0+20 System 1 EAST SIDE Station 1+10 System 1 SOUTH SIDE Station 1+70 System 1 WEST SIDE Station 2+20 System 2 Temporary Micropile Wall Sections June 27, 2016 Residence 541 Race Street 16-024G-D1 BY-5 of 6 RDJ Project Number: Date:Sheet Number:Prepared by:Project: Sheet Revisions Date Revision/Issue Prepared by B&Y Drilling, Inc. Designed For:Seal: Notes: 1. The micropile wall and temporary slopes shall be constructed entirely within property boundaries. 266 Red Cliff Circle Glenwood Springs, CO 81601 Phone: (970) 230-9208 SCALE: HORIZONTAL 1" = 10' VERTICAL 1" = 10' ABBREVIATIONS EG - Existing Grade TOW - Top of Wall BOE - Bottom of Excavation Injection Bar Field Installed Grout MICROPILE CROSS SECTION A-A' Borehole MICROPILE BEARING PLATE FRONT VIEW 8" Micropile Hole Diameter = Bar Diameter +1/4"8" 1/2" Min Hex Nut Bearing Plate MICROPILE DETAIL Grout A'A Williams Injection Bar 6" Min 9" Column MICROPILE BEARING PLATE SIDE VIEW Cross Bar, 24" OC Vertical Pile MICROPILE CAP PLAN VIEW VERTICAL SYSTEM SYSTEM 1 MICROPILE CAP CROSS SECTION VERTICAL SYSTEM SYSTEM 1 12" 20" Cross Bar, #4 Rebar Continuous Waler, #4 Rebar 3" 2" min. 3,000 psi Concrete Grout Vertical Pile Continuous Waler, #4 Rebar Notes: Vertical piles 12" center to center with back row at 12" offset 12" 12" Continuous Waler, #4 Rebar Continuous Waler, #4 Rebar TYPICAL SECTION SYSTEM 1 15.0' MAX CUT EXISTING GRADE VARIES PROPOSED EXCAVATION RL = 2 0 ' MICROPILE CAP SEE DETAILS VARIES 2' MAX. DH=16.0' MAX. WILLIAMS 38mm INJECTION BAR BOTTOM OF EXCAVATION (SEE SHEET BY-3) SEE SHEET BY-3 FOR TOP OF CAP/WALL EL. PROPOSED TEMPORARY EXCAVATION AT 1.5H:1V Cross bar, 36" OC Continuous waler, #4 rebar Vertical pile 12" 18" 36" Cross bar, #4 Rebar Continuous Waler, #4 Rebar 3" 2" min. 3,000 psi Concrete Grout Continuous Waler, #4 Rebar Battered pile Battered pile Vertical pile 18" 18" Continuous waler, #4 rebar 36" Notes: Vertical pile 18" center to center Battered pile 36" center to center MICROPILE CAP PLAN VIEW BATTERED SYSTEM SYSTEM 2 MICROPILE CAP CROSS SECTION BATTERED SYSTEM SYSTEM 2 VARIES PROPOSED EXCAVATION R L = 1 5 ' RL = 2 0 ' WILLIAMS 32mm INJECTION BAR WILLIAMS 38mm INJECTION BAR PROPOSED TEMPORARY EXCAVATION AT 1.5H:1V 20° TYPICAL SECTION SYSTEM 2 15.0' MAX. CUT VARIES 2' MAX. DH=15.0' MAX. 5'8" MICROPILE CAP SEE DETAILS EXISTING GRADE BOTTOM OF EXCAVATION (SEE SHEET BY-3) SEE SHEET BY-3 FOR TOP OF CAP/WALL EL. Temporary Micropile Wall Typical Sections and Details June 27, 2016 Residence 541 Race Street 16-024G-D1 BY-6 of 6 RDJ Project Number: Date:Sheet Number:Prepared by:Project: Sheet Revisions Date Revision/Issue Prepared by B&Y Drilling, Inc. Designed For:Seal: NOT TO SCALE Abbreviations: RL - Reinforcement Length DH - Design Height 266 Red Cliff Circle Glenwood Springs, CO 81601 Phone: (970) 230-9208 NOTES: 1. See Sheet BY-3 for top of wall/cap and bottom of excavation elevations. N 10/04/17 DATE OF PUBLICATION 200' 400'800'100' 1" = 200'C-0.0 COVER SHEET 03/21/17 PERMIT 541 RACE STREET NOTES: 1. ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF PUBLIC IMPROVEMENTS SHALL MEET OR EXCEED THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE CITY OF ASPEN ("COA") MUNICIPAL CODE, COA TECHNICAL MANUALS, AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEEN THESE PLANS AND THE TECHNICAL MANUAL OR ANY APPLICABLE STANDARDS, THE HIGHER QUALITY STANDARD SHALL APPLY. ALL UTILITY WORK SHALL BE INSPECTED AND APPROVED BY THE UTILITY. 2. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED UPON AS BEING EXACT OR COMPLETE. 3. THE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THE APPROPRIATE CRITERIA AND SPECIFICATIONS, AND A COPY OF ANY PERMITS AND EXTENSION AGREEMENTS NEEDED FOR THE JOB ONSITE AT ALL TIMES. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO, EXCAVATION, TRENCHING, SHORING,TRAFFIC CONTROL, AND SECURITY. 5. IF DURING THE CONSTRUCTION PROCESS CONDITIONS ARE ENCOUNTERED WHICH COULD INDICATE A SITUATION THAT IS NOT IDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL CONTACT THE WOODY CREEK ENGINEERING, LLC IMMEDIATELY. 6. ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD UNLESS SPECIFICALLY STATED OTHERWISE. 7. THE CONTRACTOR SHALL SUBMIT A TRAFFIC CONTROL PLAN IN ACCORDANCE WITH MUTCD TO THE APPROPRIATE RIGHT-OF-WAY AUTHORITY (TOWN, COUNTY OR STATE) FOR APPROVAL PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN OR AFFECTING THE RIGHT-OF-WAY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BY THE CONSTRUCTION ACTIVITIES. 8. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THE COMPLETION OF THE INTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR AS DESIGNATED TO BE PROVIDED, INSTALLED, OR CONSTRUCTED UNLESS SPECIFICALLY NOTED OTHERWISE. 9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE AND CLEAR OF ALL CONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE. 10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING AS-BUILT INFORMATION ON A SET OF RECORD DRAWINGS KEPT ON THE CONSTRUCTION SITE AND AVAILABLE AT ALL TIMES. 11. DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. IF PERTINENT DIMENSIONS ARE NOT SHOWN, CONTACT WOODY CREEK ENGINEERING, LLC FOR CLARIFICATION AND ANNOTATE THE DIMENSION ON THE AS-BUILT RECORD DRAWINGS. 15. THE CONTRACTOR SHALL COMPLY WITH ALL TERMS AND CONDITIONS OF THE COLORADO PERMIT FOR STORM WATER DISCHARGE, THE STORM WATER MANAGEMENT PLAN, AND THE EROSION CONTROL PLAN. 16. ALL STRUCTURAL EROSION CONTROL MEASURES SHALL BE INSTALLED AT THE LIMITS OF CONSTRUCTION PRIOR TO ANY OTHER EARTH-DISTURBING ACTIVITY. ALL EROSION CONTROL MEASURES SHALL BE MAINTAINED IN GOOD REPAIR BY THE CONTRACTOR UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREA IS STABILIZED WITH HARD SURFACE OR LANDSCAPING. 17. THE CONTRACTOR SHALL SEQUENCE INSTALLATION OF UTILITIES IN SUCH A MANNER AS TO MINIMIZE POTENTIAL UTILITY CONFLICTS. IN GENERAL, STORM SEWER AND SANITARY SEWER SHOULD BE CONSTRUCTED PRIOR TO INSTALLATION OF THE WATER LINES AND DRY UTILITIES. 18. HEAT TAPE ALL PIPES. 19. 100'-0" = 7935'-1.2" VICINITY MAP 54 1 R A C E 54 1 R A C E S T R E E T , A S P E N , C O 10/04/17 CHECK SET 10/14/2017 10/4/2017 I storm grates N89°20'00"W 85.41' N89°20'00"W 85.41' N0 0 ° 4 0 ' 0 0 " E 71 . 0 5 ' S0 0 ° 4 0 ' 0 0 " W 71 . 0 5 ' 6068.38 sq.ft.+/- LOT 6 RA C E A L L E Y 20 ' R I G H T O F W A Y B1 A1 A2 A3 A4 A5 A6 A7 C D E F B2 7933 79 3 3 7 9 3 5 7934 7 9 3 5 7935 7936 7937 7934 storm grates N89°20'00"W 85.41' N89°20'00"W 85.41' N0 0 ° 4 0 ' 0 0 " E 71 . 0 5 ' S0 0 ° 4 0 ' 0 0 " W 71 . 0 5 ' 6068.38 sq.ft.+/- LOT 6 RA C E A L L E Y 20 ' R I G H T O F W A Y 79 3 3 7932 79 3 4 79 3 6 79 3 7 79 3 6 79 3 7 79 3 8 79 3 7 793 6 7 9 3 5 7 9 3 4 79 3 3 79 3 2 79 3 5 793 1 7 9 3 2 EX1 EX2 79 3 8 N 10'20'40'5' 1" = 10' C-1.0 BASINS NOTES: 1. EXISTING DRAINAGE BASIN CONSISTS OF LOT. 2. PROPOSED DRAINAGE BASINS ARE DETERMINED BY TOPOGRAPHY AND STRUCTURE. HISTORICAL DRAINAGE BASINS PROPOSED DRAINAGE BASINS HISTORICAL DRAINAGE BASINS PROPOSED DRAINAGE BASINS 54 1 R A C E 54 1 R A C E S T R E E T , A S P E N , C O 10/04/17 DATE OF PUBLICATION 03/21/17 PERMIT CHECK SET10/04/17 10/14/201710/4/2017 7935 7937.75 storm grates N89°20'00"W 85.41' N89°20'00"W N0 0 ° 4 0 ' 0 0 " E 71 . 0 5 ' S0 0 ° 4 0 ' 0 0 " W 71 . 0 5 ' 6068.38 sq.ft.+/- LOT 6 RA C E A L L E Y 20 ' R I G H T O F W A Y 79 3 3 7932 79 3 4 7 9 3 6 79 3 7 79 3 6 79 3 7 7 9 3 5 7 9 3 4 79 3 3 79 3 2 79 3 5 793 1 7 9 3 2 -2.0% 4" TRENCH DRAIN PIPE B PIPE C 1X SILVA CELLS COVER = 2 FT AREA = 204 SF PIPE D PUMP VAULT -2.0% -2.1% TW=7935 TW=7936 -12.5% -0 . 0 % 6" TRENCH DRAIN -8.0% -2.0% TOW=VARIES <=30" HEIGHT 2.0% 7933 79 3 3 7 9 3 5 7934 7936 7937 7 9 3 5 7935 7934 79 3 2 - 7 . 7 % -1 2 . 8 % -13.7 % FOUR RISERS FF=7935 FT FF=7937.6 FT FF=7935 FT FF=7935.1 FT FOUR RISERS FLOW LINE TBC INTEGRAL DECK DRAIN ONE 4" PVC PIPE IE:7935.01 INTEGRAL DECK DRAIN TWO 4" PVC PIPE IE:7935.01 CONNECT TO TRENCH DRAIN PIPE E OUTLET -1.9% -2.7% -2.4% TW=7927.87GREEN ROOF: 7935 SLOPE > 2% TW=7937.27 TW=7936 7935 TW=7938 TW=7938 TW = 7928.91 PIPE F PIPE G PIPE H 6" PERF. PVC PIPE TD=7937.19 TD=7924.56 TD=7934.85 TOW = 7934.0 PLANTER -3 . 8 % 7933.16 7935.20 7935.48 7935.30 7934.89 7934.17 7933.39 7933.83 7934.70 7935.05 7935.10 7934.85 7934.96 7934.98 7934.85 7937.60 7934.89 7934.89 7935.10 7935.08 7934.98 WO: 7924.77 BW = 7924.55 WO: 7924.77 BW = 7924.55 TW = 7927.87 TW = 7927.87 BW = 7927.58 BW = 7927.87 BW = 7927.87 7934 7937.60 TBC = 7937.19 7937.75 FLOW LINE = 7937.42 7933.00 7935.20 7936.28 7937.60 7937.60 FLOW LINE = 7937.48 TD = 7927.58 7935.43 7935.72 BW = 7929.05 BW = 7929.05 BW = 7929.05 TW = 7927.87 BW = 7927.87 7932.81 7933.47 7934.98 DRAINAGE EASEMENT (HATCHED) TIE INTO EXISTING STRUCTURE 1.56 IN ORIFICE INV = 7919.13 FT EXISTING STRUCTURE GR=7928.83 FT INV IN=7926.45 FT (E) INV IN = 7919.14 FT (N) INV OUT = 7919.07 FT (W) OUTLET IE=7926.97 FT 7932.65 7932.99INLET IE=7929.15 FT TBC = 7937.14 TBC = 7937.37 -3 . 2 % 1. 6 % CURB TOW:7935.5 TOW:7935.8 79 3 8 7935.06 7935.06 7935.06 7935.06 -1.04% -1.04% 7935.06 7935.06 7935.15 7935.26 7935.29 7935.48 7935.09 7933 DO NOT GRADE ON ADJACENT PROPERTY OTHER SIDE OF SWALE SHOWN FOR REFERNCE INSTALL TYPE A CURB AND GUTTER INSTALL TYPE A CURB AND GUTTER INSTALL TYPE A CURB AND GUTTER TOW = 7940.25 7936 7937 7937 7936 ERRANT VEHICLE PROTECTION WALL PROVIDE MINIMUM 2-FT DISTANCE FROM FACE OF CURB TO FACE OF WALL WIDTH=10-IN SEE STRUCTURAL PLANS (SDA-01) FOR DETAIL 7938.5 7938.5 N 5'10'20'2.5' 1" = 5' C-2.0 GRADING & DRAINAGE 54 1 R A C E EXISTING TREE REMOVED EXISTING TREE KEPT EXISTING CONTOUR PROPOSED CONTOUR NOTES: 1. ROOF AREA = 3089 SF 2. TOTAL IMPERVIOUS AREA= 3873 SF. 3. UTILITY LOCATIONS UNKNOWN AND ASSUMED. REPLACE CURB AND GUTTER IF DAMANGED DURING CONSTRUCTION. 4. ALL INLETS ARE NDS 6" ROUND GRATES WITH SPEE-D CATCH BASINS 7910 SPOT ELEVATION XXXX.XX CONC. = CONCRETE HP = HIGH POINT TD = TRENCH DRAIN UTILITY SERVICE E=ELECTRIC UG=UNDERGROUND GAS SS=SANITARY SEWER W=WATER 54 1 R A C E S T R E E T , A S P E N , C O DATE OF PUBLICATION 03/21/17 PERMIT STRUCTURE IMPERVIOUS PERMIT 6/28/2018 6/28//18 1/11/20186/28/2018 PROPOSED SURFACE 7900.00 7910.00 7920.00 7930.00 7940.00 7950.00 7960.00 0+00.00 0+25.00 0+50.00 0+75.00 1+00.00 1+25.00 1+50.00 1+75.00 7920.00 7930.00 7940.00 0+00.00 0+25.00 0+29.90 PIPE B 2% SLOPE TRENCH DRAIN PIPE D 2% SLOPE PIPE C 2% SLOPE STA:0+10.57 ELEV:7924.56 STA:0+22.42 ELEV:7927.58 STA:0+09.79 ELEV:7935.06 STA:0+10.40 ELEV:7923.24 STA:0+17.46 ELEV:7925.42 STA:0+22.58 ELEV:7925.51 2 MUNRO FS E 1 3 HP SUMP PUMPS FLOAT SWITCHES AT 7922.04 STA:0+14.09 ELEV:7923.17 STA:0+17.83 ELEV:7922.19 STA:0+20.94 ELEV:7922.28 STA:0+13.83 ELEV:7921.18 M/D/YYSD NOT FOR CONST. XX/XX/XXCD FOR CONST. C-3.1 PROFILES & CROSS-SECTIONS COURTWELL PROFILE AND PUMP VAULT INCLUDING PIPE B,C,D PIPE A PROFILE NOTES: 1. TRENCH DRAIN IS ZURN Z-706 WITH HEAVY DUTY DUCTILE IRON SLOTTED GRATE - TRAFFIC RATED SEE DETAILS C-4.0. 2. INLETS AND INLET GRATES ARE NDS 9" CATCH BASIN SERIES AND NDS 980-9" SQ. GRATES. SEE DETAILS C-4.0. DATE OF PUBLICATION 03/21/17 PERMIT 54 1 R A C E 54 1 R A C E S T R E E T , A S P E N , C O CHECK SET 10/04/17 10/04/17 10/14/201710/4/2017 7910.00 7920.00 7930.00 7940.00 7950.00 7960.00 0+00.00 0+15.00 7900.00 7910.00 7920.00 7930.00 7940.00 7950.00 7960.00 0+00.00 0+21.00 7900.00 7910.00 7920.00 7930.00 7940.00 7950.00 7960.00 0+00.00 0+21.00 M/D/YYSD NOT FOR CONST. XX/XX/XXCD FOR CONST. C-3.2 PROFILES & CROSS-SECTIONS PIPE F PROFILE PIPE H PROFILE PIPE G PROFILE DATE OF PUBLICATION 03/21/17 PERMIT 54 1 R A C E 54 1 R A C E S T R E E T , A S P E N , C O CHECK SET 10/04/17 10/04/17 10/4/2017 7910.00 7920.00 7930.00 7940.00 7950.00 7960.00 0+00.00 0+25.00 0+50.00 0+75.00 0+76.69 PROPOSED SURFACE 7915.00 7920.00 7930.00 0+00.00 0+25.00 0+50.00 0+60.00 STA:0+17.03 ELEV:7926.76 STA:0+00.00 ELEV:7926.97 STA:0+00.00 ELEV:7928.83 STA:0+00.00 ELEV:7930.22 STA:0+58.72 ELEV:7919.13 STA:0+00.00 ELEV:7926.76 M/D/YYSD NOT FOR CONST. XX/XX/XXCD FOR CONST. C-3.3 PROFILES & CROSS-SECTIONS PIPE E PROFILE NOTES: 1. TRENCH DRAIN IS ZURN Z-706 WITH HEAVY DUTY DUCTILE IRON SLOTTED GRATE - TRAFFIC RATED SEE DETAILS C-4.0. 2. INLETS AND INLET GRATES ARE NDS 9" CATCH BASIN SERIES AND NDS 980-9" SQ. GRATES. SEE DETAILS C-4.0. PIPE I PROFILE DATE OF PUBLICATION 03/21/17 PERMIT 54 1 R A C E 54 1 R A C E S T R E E T , A S P E N , C O CHECK SET 10/04/17 10/04/17 10/14/2017 10/4/2017 7935 7935.50 TW = 7928.91 7935 TW = 7928.91 7935.06 7935.06 7935.06 7935.06 -1.04% -1.04% 7935.06 7935.06 N M/D/YYSD NOT FOR CONST. 5'10'20'2.5' XX/XX/XXCD FOR CONST. 1" = 5' C-4.0 UTILITIES DATE OF PUBLICATION 03/21/17 PERMIT 54 1 R A C E 54 1 R A C E S T R E E T , A S P E N , C O PERMIT 10/04/17 4/12/18 TRENCH DRAIN DETAIL CATCH BASIN AND GRATE DETAIL DECK DRAIN SILVA CELL DETAIL M/D/YYSD NOT FOR CONST. XX/XX/XXCD FOR CONST. C-5.1 DETAILS DATE OF PUBLICATION 03/21/17 PERMIT 54 1 R A C E 54 1 R A C E S T R E E T , A S P E N , C O 2'4'8'1' SCALE: 1" = 2' CURB AND GUTTER DETAIL CHECK SET 10/04/17 10/04/17 10/14/201710/4/2017 M/D/YYSD NOT FOR CONST. XX/XX/XXCD FOR CONST. C-5.2 DETAILS SEDIMENT FENCE DETAIL TRACK PAD DETAIL DATE OF PUBLICATION 03/21/17 PERMIT 54 1 R A C E 54 1 R A C E S T R E E T , A S P E N , C O ORIFICE PLATE DETAIL PUMP DETAIL MUNRO FS E 1/3HP SUMP PUMP PERMIT 10/04/17 4/12/18 3/16/20184/12/2018 I RA C E A L L E Y 20 ' R I G H T O F W A Y TR A C K P A D 18 ' X 5 ' N M/D/YYSD NOT FOR CONST. 5'10'20'2.5' XX/XX/XXCD FOR CONST. 1" = 5' C-6.0 SEDIMENT AND EROSION CONTROL DATE OF PUBLICATION 03/21/17 PERMIT 54 1 R A C E 54 1 R A C E S T R E E T , A S P E N , C O CHECK SET 10/04/17 10/04/17 10/14/201710/4/2017 0'10' 20' Cover, Index and Notes 2017-02-23 Owner Review 2017-03-01 HPC Final Review2017-03-22 Building Permit2018-06-29 Building Permit Rev01 541 RACE ALLEY | LINE SHACKS BUILDING PERMIT REV01: JUNE 29, 2018 Issuance 0' 2' 4' Landscape Development Plan 2017-02-14 Coordination 2017-02-22 Coordination 2017-02-23 Owner Review2017-03-01 HPC Final Review2017-03-22 Building Permit2018-06-29 Building Permit Rev01 Issuance BE N C H GA S F I R E PL A N T E R W A L L BE N C H COUCH COUCH TABLE WINDOW WELL (RE ARCH) WINDOW WELL (RE ARCH) FR O N T P O R C H ( R E A R C H ) FR O N T P O R C H ( R E A R C H ) CU R B LA W N P A T H PLANT CONT. GATE GATE SITE WALL EGRESS LADDER; RE ARCH OVERHEAD HEATER TO LOWER LEVEL PATIO, TYP WRAP TILE UP FACE OF LOWER LEVEL FIRE FEATURE WALL HE A T E R HE A T E R HE A T E R CR A S H R A T E D W A L L ; R E C I V I L A N D S T R L 8/17/18 nickt 0' 2' 4' Planting Plan 2017-02-14 Coordination Set 2017-02-23 Owner Review2017-03-01 HPC Final Review2017-03-22 Building Permit2018-06-29 Building Permit Rev01 Issuance 0' 2' 4' Lighting Plan 2017-02-14 Coordination Set 2017-02-23 Owner Review 2017-03-01 HPC Final Review 2017-03-22 Building Permit Issuance Sections 2017-02-14 Coordination Set 2017-03-01 HPC Final Review2017-03-22 Building Permit2018-06-29 Building Permit Rev01 Issuance 8/17/18 nickt Lighting Cutsheets 2017-02-14 Coordination Set 2017-03-01 HPC Final Review 2017-03-22 Building Permit Issuance LIGHT 00 LIGHT 03 LIGHT 01 LIGHT 02 75mm 350mm Product Cutsheets 2017-03-22 Building Permit Issuance FIRE FEATURE APPLIANCE LAWN PAVE SYSTEM OUTDOOR HEATER PORCELAIN TILE ISSUE: 98% SD HPC: 11.30.2015, 4.27.16, 12.8.16 PROGRESS: 5.16.16, 6.12.16, 6.23.16 11.2.16 HPC: 3.1.17 PERMIT: 3.22.17 CONSTRUCTION: PROJECT # 1403 FILENAME: 1403 ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO 81611 CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE STRUCTURAL DESIGN 1040 MAIN ST CARBONDALE, CO 81623 CONTACT: SARA MICKUS (V) 970.510-0773 SURVEYOR HIRED GUN SURVEYING P.O. BOX 9 SNOWMASS, CO 81654 CONTACT: TOM YOKUM (V) (970) 923-2794 LANDSCAPE ARCHITECT LIFT STUDIO PO BOX 2748 ASPEN, CO 81612 CONTACT: RYAN VUGTEVEEN (V) (970) 404 5610 CIVIL ENGINEER WOODY CREEK ENGINEERING,LLC 520 E. HYMAN AVE. #201 ASPEN, CO 81612 CONTACT: JOSH RICE (V) 970 309 7130 SOILS ENGINEER CHURCH AND ASSOCIATES, INC 4501 WADSWORTH BLVD WHEATRIDGE, CO 80033 (V) 303 463 9317 MECHANICAL CONSULTANT DESIGN-BUILD BY GC GENERAL CONTRACTOR TBD. FOX CROSSING PROPERTIES LOTS 4&6 LLC 6330 MERCER STREET HOUSTON, TEXAS 77005 CONTACT: JOHN MORTON VC: 713 299 7674 A.199 temporary location for transplanted trees. provide protective fencing. tree permit notes 5.25.18 in red 8/17/18 nickt LA LB LC LE LG 001 002 003 004 005 006 007 008 009 010 011 012 014 015 013 009 ISSUE: 98% SD HPC: 11.30.2015, 4.27.16, 12.8.16 PROGRESS: 5.16.16, 6.12.16, 6.23.16 11.2.16 HPC FINAL: 3.1.17 PERMIT: CONSTRUCTION: PERMIT RESPONCE: 6.27.17 PROJECT # 1403 FILENAME: 1403 CONSULTANTS ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO 81611 CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE STRUCTURAL DESIGN 1040 MAIN ST CARBONDALE, CO 81623 CONTACT: SARA MICKUS (V) 970.510-0773 SURVEYOR HIRED GUN SURVEYING P.O. BOX 9 SNOWMASS, CO 81654 CONTACT: TOM YOKUM (V) (970) 923-2794 LANDSCAPE ARCHITECT LIFT STUDIO PO BOX 2748 ASPEN, CO 81612 CONTACT: RYAN VUGTEVEEN (V) (970) 404 5610 CIVIL ENGINEER WOODY CREEK ENGINEERING,LLC 520 E. HYMAN AVE. #201 ASPEN, CO 81612 CONTACT: JOSH RICE (V) 970 309 7130 SOILS ENGINEER CHURCH AND ASSOCIATES, INC 4501 WADSWORTH BLVD WHEATRIDGE, CO 80033 (V) 303 463 9317 MECHANICAL CONSULTANT DESIGN-BUILD BY GC GENERAL CONTRACTOR TBD. OWNERS FOX CROSSING PROPERTIES LOTS 4&6 LLC 6330 MERCER STREET HOUSTON, TEXAS 77005 CONTACT: JOHN MORTON VC: 713 299 7674 RACE ALLEY 541 RACE STREET ASPEN, CO 81611 PARCEL ID # 273707392007 NORTH FLOOR AREA CALCULATIONS Z010 NORTH NORTH ISSUE: 98% SD HPC: 11.30.2015, 4.27.16, 12.8.16 PROGRESS: 5.16.16, 6.12.16, 6.23.16 11.2.16 HPC: 3.1.17 PERMIT: 3.22.17 CONSTRUCTION: PROJECT # 1403 FILENAME: 1403 CONSULTANTS ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO 81611 CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE STRUCTURAL DESIGN 1040 MAIN ST CARBONDALE, CO 81623 CONTACT: SARA MICKUS (V) 970.510-0773 SURVEYOR HIRED GUN SURVEYING P.O. BOX 9 SNOWMASS, CO 81654 CONTACT: TOM YOKUM (V) (970) 923-2794 LANDSCAPE ARCHITECT LIFT STUDIO PO BOX 2748 ASPEN, CO 81612 CONTACT: RYAN VUGTEVEEN (V) (970) 404 5610 CIVIL ENGINEER WOODY CREEK ENGINEERING,LLC 520 E. HYMAN AVE. #201 ASPEN, CO 81612 CONTACT: JOSH RICE (V) 970 309 7130 SOILS ENGINEER CHURCH AND ASSOCIATES, INC 4501 WADSWORTH BLVD WHEATRIDGE, CO 80033 (V) 303 463 9317 MECHANICAL CONSULTANT DESIGN-BUILD BY GC GENERAL CONTRACTOR TBD. OWNERS FOX CROSSING PROPERTIES LOTS 4&6 LLC 6330 MERCER STREET HOUSTON, TEXAS 77005 CONTACT: JOHN MORTON VC: 713 299 7674 RACE ALLEY 541 RACE STREET ASPEN, CO 81611 PARCEL ID # 273707392007 ARCHITECTURAL SITE PLAN A.200 NORTH 8/17/18 nickt LA LB LC LE LG 001 002 003 004 005 006 007 008 009 010 011 012 014 015 013 009 ISSUE: 98% SD HPC: 11.30.2015, 4.27.16, 12.8.16 PROGRESS: 5.16.16, 6.12.16, 6.23.16 11.2.16 HPC FINAL: 3.1.17 PERMIT SUBMITTAL: 3.22.17, 10.13.17 CONSTRUCTION: PROJECT # 1403 FILENAME: 1403 CONSULTANTS ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO 81611 CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE STRUCTURAL DESIGN 1040 MAIN ST CARBONDALE, CO 81623 CONTACT: SARA MICKUS (V) 970.510-0773 SURVEYOR HIRED GUN SURVEYING P.O. BOX 9 SNOWMASS, CO 81654 CONTACT: TOM YOKUM (V) (970) 923-2794 LANDSCAPE ARCHITECT LIFT STUDIO PO BOX 2748 ASPEN, CO 81612 CONTACT: RYAN VUGTEVEEN (V) (970) 404 5610 CIVIL ENGINEER WOODY CREEK ENGINEERING,LLC 520 E. HYMAN AVE. #201 ASPEN, CO 81612 CONTACT: JOSH RICE (V) 970 309 7130 SOILS ENGINEER CHURCH AND ASSOCIATES, INC 4501 WADSWORTH BLVD WHEATRIDGE, CO 80033 (V) 303 463 9317 MECHANICAL CONSULTANT DESIGN-BUILD BY GC GENERAL CONTRACTOR TBD. OWNERS FOX CROSSING PROPERTIES LOTS 4&6 LLC 6330 MERCER STREET HOUSTON, TEXAS 77005 CONTACT: JOHN MORTON VC: 713 299 7674 RACE ALLEY 541 RACE STREET ASPEN, CO 81611 PARCEL ID # 273707392007 LOWER FLOOR PLAN PROPOSED A201 NORTH EE EE HR GR EE DE ET SA CO SA SA V DV V SA V RED NOTES - REF. PERMIT CONDITIONS AND ABBREVIATION KEY 8/17/18 nickt G/D GR HR SA SA CO CO V DV V MA RED NOTES - REF. PERMIT CONDITIONS AND ABBREVIATION KEY 8/17/18 nickt ISSUE: 98% SD HPC: 11.30.2015, 4.27.16, 12.8.16 PROGRESS: 5.16.16, 6.12.16, 6.23.16 11.2.16 HPC FINAL: 3.1.17 PERMIT: 3.22.17, 10.13.17 CONSTRUCTION: PROJECT # 1403 FILENAME: 1403 ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO 81611 CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE STRUCTURAL DESIGN 1040 MAIN ST CARBONDALE, CO 81623 CONTACT: SARA MICKUS (V) 970.510-0773 SURVEYOR HIRED GUN SURVEYING P.O. BOX 9 SNOWMASS, CO 81654 CONTACT: TOM YOKUM (V) (970) 923-2794 LANDSCAPE ARCHITECT LIFT STUDIO PO BOX 2748 ASPEN, CO 81612 CONTACT: RYAN VUGTEVEEN (V) (970) 404 5610 CIVIL ENGINEER WOODY CREEK ENGINEERING,LLC 520 E. HYMAN AVE. #201 ASPEN, CO 81612 CONTACT: JOSH RICE (V) 970 309 7130 SOILS ENGINEER CHURCH AND ASSOCIATES, INC 4501 WADSWORTH BLVD WHEATRIDGE, CO 80033 (V) 303 463 9317 MECHANICAL CONSULTANT DESIGN-BUILD BY GC GENERAL CONTRACTOR TBD. FOX CROSSING PROPERTIES LOTS 4&6 LLC 6330 MERCER STREET HOUSTON, TEXAS 77005 CONTACT: JOHN MORTON VC: 713 299 7674 A203  8/17/18 nickt GF GG GN GOGM GP GL GA GB GD GE GC ELEVATIONS A301 ISSUE: 98% SD HPC: 11.30.2015, 4.27.16, 12.8.16 PROGRESS: 5.16.16, 6.12.16, 6.23.16 11.2.16 HPC FINAL: 3.1.17 PERMIT: 3.22.17 CONSTRUCTION: PROJECT # 1403 FILENAME: 1403 CONSULTANTS ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO 81611 CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE STRUCTURAL DESIGN 1040 MAIN ST CARBONDALE, CO 81623 CONTACT: SARA MICKUS (V) 970.510-0773 SURVEYOR HIRED GUN SURVEYING P.O. BOX 9 SNOWMASS, CO 81654 CONTACT: TOM YOKUM (V) (970) 923-2794 LANDSCAPE ARCHITECT LIFT STUDIO PO BOX 2748 ASPEN, CO 81612 CONTACT: RYAN VUGTEVEEN (V) (970) 404 5610 CIVIL ENGINEER WOODY CREEK ENGINEERING,LLC 520 E. HYMAN AVE. #201 ASPEN, CO 81612 CONTACT: JOSH RICE (V) 970 309 7130 SOILS ENGINEER CHURCH AND ASSOCIATES, INC 4501 WADSWORTH BLVD WHEATRIDGE, CO 80033 (V) 303 463 9317 MECHANICAL CONSULTANT DESIGN-BUILD BY GC GENERAL CONTRACTOR TBD. OWNERS FOX CROSSING PROPERTIES LOTS 4&6 LLC 6330 MERCER STREET HOUSTON, TEXAS 77005 CONTACT: JOHN MORTON VC: 713 299 7674 RACE ALLEY 541 RACE STREET ASPEN, CO 81611 PARCEL ID # 273707392007 8/17/18 nickt GS GT GV GH GI GJ GP GQ GR GS GK ISSUE: PROGRESS: 98% SD HPC SUBMITTAL:4.27.2016, 12.9.16 PROGRESS: 5.16.2016 6.12.16 HPC FINAL: 3.1.17 PERMIT SUBMITTAL: 3.22.17 CONSTRUCTION: PROJECT # 1403 FILENAME: 1403 CONSULTANTS ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO 81611 CONTACT: WILLIS PEMBER 970 920 1727 STRUCTURAL ENGINEER EVOLVE STRUCTURAL DESIGN 1040 MAIN ST CARBONDALE, CO 81623 CONTACT: SARA MICKUS 970.510-0773 SURVEYOR HIRED GUN SURVEYING PO BOX 9 SNOWMASS, CO 81654 CONTACT: TOM YOKUM 970 923-2794 LANDSCAPE ARCHITECT LIFT STUDIO PO BOX 2748 ASPEN, CO 81612 CONTACT: RYAN VUGTEVEEN 970 404 5610 CIVIL ENGINEER WOODY CREEK ENGINEERING,LLC 520 E. HYMAN AVE. #201 ASPEN, CO 81612 CONTACT: JOSH RICE 970 309 7130 SOILS ENGINEER CHURCH AND ASSOCIATES, INC 4501 WADSWORTH BLVD WHEATRIDGE, CO 80033 303 463 9317 MECHANICAL CONSULTANT DESIGN-BUILD BY GC GENERAL CONTRACTOR TBD. OWNERS FOX CROSSING PROPERTIES LOTS 4&6 LLC 6330 MERCER STREET HOUSTON, TEXAS 77005 CONTACT: JOHN MORTON RACE ALLEY 541 RACE STREET ASPEN, CO 81611 PARCEL ID # 273707392007 ELEVATIONS A302 ISSUE: 98% SD HPC: 11.30.2015, 4.27.16, 12.8.16 PROGRESS: 5.16.16, 6.12.16, 6.23.16 11.2.16 HPC FINAL: 3.1.17 PERMIT: 3.22.17 CONSTRUCTION: PROJECT # 1403 FILENAME: 1403 CONSULTANTS ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO 81611 CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE STRUCTURAL DESIGN 1040 MAIN ST CARBONDALE, CO 81623 CONTACT: SARA MICKUS (V) 970.510-0773 SURVEYOR HIRED GUN SURVEYING P.O. BOX 9 SNOWMASS, CO 81654 CONTACT: TOM YOKUM (V) (970) 923-2794 LANDSCAPE ARCHITECT LIFT STUDIO PO BOX 2748 ASPEN, CO 81612 CONTACT: RYAN VUGTEVEEN (V) (970) 404 5610 CIVIL ENGINEER WOODY CREEK ENGINEERING,LLC 520 E. HYMAN AVE. #201 ASPEN, CO 81612 CONTACT: JOSH RICE (V) 970 309 7130 SOILS ENGINEER CHURCH AND ASSOCIATES, INC 4501 WADSWORTH BLVD WHEATRIDGE, CO 80033 (V) 303 463 9317 MECHANICAL CONSULTANT DESIGN-BUILD BY GC GENERAL CONTRACTOR TBD. OWNERS FOX CROSSING PROPERTIES LOTS 4&6 LLC 6330 MERCER STREET HOUSTON, TEXAS 77005 CONTACT: JOHN MORTON VC: 713 299 7674 RACE ALLEY 541 RACE STREET ASPEN, CO 81611 PARCEL ID # 273707392007 8/17/18 nickt W16x77 W8x352x8's ISSUE: PROGRESS: 98% SD HPC SUBMITTAL:4.27.2016, 12.9.16 PROGRESS: 5.16.2016 6.12.16 HPC: 3.1.17 PERMIT SUBMITTAL: 3.22.17, 10.13.17 CONSTRUCTION: PROJECT # 1403 FILENAME: 1403 CONSULTANTS ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE ENGINEERING 1040 MAIN STREET CARBONDALE, CO 81623 CONTACT: SARA MICKUS (970) 618 7708 SURVEYOR HIRED GUN SURVEYING P.O. BOX 9 SNOWMASS, CO 81654 CONTACT: TOM YOKUM (V) (970) 923-2794 LANDSCAPE ARCHITECT LIFT STUDIO LLC PO BOX 2748 ASPEN, CO 81612 CONTACT: RYAN V 970 404 5610 CIVIL ENGINEER WOODY CREEK ENGINEERING, LLC P.O. BOX 575 WOODY CREEK, CO 81656 CONTACT: JOSH RICE 970 309 7130 SOILS ENGINEER CHURCH AND ASSOCIATES, INC 4501 WADSWORTH BLVD WHEATRIDGE, CO 80033 (V) 303 463 9317 MECHANICAL CONSULTANT DESIGN BUILD GENERAL CONTRACTOR RUDD CONSTRUCTION 132 PARK AVENUE BASALT, CO 81621 CONTACT: SCOTT DURYEA (V) 970 618 7200 OWNERS FOX CROSSING PROPERTIES LOTS 4&6 LLC 6330 MERCER STREET HOUSTON, TEXAS 77005 CONTACT: JOHN MORTON RACE ALLEY 541 RACE STREET ASPEN, CO 81611 PARCEL ID # 273707392007 SECTIONS A401 8/17/18 nickt   ISSUE: PROGRESS: 98% SD HPC SUBMITTAL:4.27.2016, 12.9.16 PROGRESS: 5.16.2016 6.12.16 HPC: 3.1.17 PERMIT SUBMITTAL: 3.22.17, 10.13.17 CONSTRUCTION: PROJECT # 1403 FILENAME: 1403 ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE ENGINEERING 1040 MAIN STREET CARBONDALE, CO 81623 CONTACT: SARA MICKUS (970) 618 7708 SURVEYOR HIRED GUN SURVEYING P.O. BOX 9 SNOWMASS, CO 81654 CONTACT: TOM YOKUM (V) (970) 923-2794 LANDSCAPE ARCHITECT LIFT STUDIO LLC PO BOX 2748 ASPEN, CO 81612 CONTACT: RYAN V 970 404 5610 CIVIL ENGINEER WOODY CREEK ENGINEERING, LLC P.O. BOX 575 WOODY CREEK, CO 81656 CONTACT: JOSH RICE 970 309 7130 SOILS ENGINEER CHURCH AND ASSOCIATES, INC 4501 WADSWORTH BLVD WHEATRIDGE, CO 80033 (V) 303 463 9317 MECHANICAL CONSULTANT DESIGN BUILD GENERAL CONTRACTOR RUDD CONSTRUCTION 132 PARK AVENUE BASALT, CO 81621 CONTACT: SCOTT DURYEA (V) 970 618 7200 FOX CROSSING PROPERTIES LOTS 4&6 LLC 6330 MERCER STREET HOUSTON, TEXAS 77005 CONTACT: JOHN MORTON A402 8/17/18 nickt ISSUE: PROGRESS: 98% SD HPC SUBMITTAL:4.27.2016, 12.9.16 PROGRESS: 5.16.2016 6.12.16 HPC: 3.1.17 PERMIT SUBMITTAL: 3.22.17, 10.13.17 CONSTRUCTION: PROJECT # 1403 FILENAME: 1403 ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE ENGINEERING 1040 MAIN STREET CARBONDALE, CO 81623 CONTACT: SARA MICKUS (970) 618 7708 SURVEYOR HIRED GUN SURVEYING P.O. BOX 9 SNOWMASS, CO 81654 CONTACT: TOM YOKUM (V) (970) 923-2794 LANDSCAPE ARCHITECT LIFT STUDIO LLC PO BOX 2748 ASPEN, CO 81612 CONTACT: RYAN V 970 404 5610 CIVIL ENGINEER WOODY CREEK ENGINEERING, LLC P.O. BOX 575 WOODY CREEK, CO 81656 CONTACT: JOSH RICE 970 309 7130 SOILS ENGINEER CHURCH AND ASSOCIATES, INC 4501 WADSWORTH BLVD WHEATRIDGE, CO 80033 (V) 303 463 9317 MECHANICAL CONSULTANT DESIGN BUILD GENERAL CONTRACTOR RUDD CONSTRUCTION 132 PARK AVENUE BASALT, CO 81621 CONTACT: SCOTT DURYEA (V) 970 618 7200 FOX CROSSING PROPERTIES LOTS 4&6 LLC 6330 MERCER STREET HOUSTON, TEXAS 77005 CONTACT: JOHN MORTON A403 8/17/18 nickt 1-1/2-3"58" 2- 3 " 2- 3 " 8" 878" 7 12"6- 7 / 8 " 34" 8- 1 / 8 " W F 8 NON-BEARING AND BEARING 634" OR 4-3/4" 5 12" OR 3 1/2" NOTE:REF. STRUCTURAL PLANS FOR INT. BEARING WALL LOCATIONS. 758" STC RATING = 50-54 FIRE RATING REQ'D - 1 HOUR OCCUPANCY SEPARATION BETWEEN GARAGE + LIVING SPACE. LOAD-BEARING 512" R ASSEMBLY = R-21.47 ASSEMBLY: GA FILE NO. WP 3240 58"5 8"78" 1-1/2-3" 2- 3 " STC RATING = 56 FIRE RATING REQ'D - 1 HOUR LESS THAN 5' FROM PROPERTY LINE LOAD-BEARING R ASSEMBLY = R-24.91 | W 8.6 CONT. ASSEMBLY: GA FILE NO. WP 3240 58"78" STC RATING = NA LOAD-BEARING R ASSEMBLY = R-49.62 STC RATING = NA NON-RATED ASSEMBLY LOAD-BEARING R ASSEMBLY = 8.6 CONTINUOUS EXISTING CONSTRUCTION HISTORIC 8" STC RATING = NA NON-RATED LOAD-BEARING R ASSEMBLY = R-24.91 | W 8.6 CONT. EXISTING HISTORIC CONSTRUCTION W/ INTERIOR INSULATION R ASSEMBLY = 21.05 | 10.1 CONT LOAD-BEARING 8"1 12" 5 8"238" NON-RATED R-ASSEMBLY = 32.86 +1 STC = NA LOAD BEARING EXTERIOR INTERIOR BEARING EXT. EGRESS WELLS NON THERMAL STC RATING = NA RATED CLASS A FIREPROOF ROOF ASSEMBLY LOAD-BEARING R ASSEMBLY = R-49.07 | 10.1 CONT 512" 112" 112" 1 2" 5 8" 7 1 4" 11 2 " 11 2" 1 2" STC RATING = NA RATED CLASS A FIREPROOF ROOF ASSEMBLY LOAD-BEARING R ASSEMBLY = R-49.07 | 10.1 CONT 5 8" 5 - 1 / 2 " HISTORIC ROOF CABIN RESTORATION HISTORIC ROOF CABIN RESTORATION NON VENTED NON VENTED 4"4" 14" RATED CLASS A FIREPROOF ROOF ASSEMBLY 38" 78" 1 1/2" = 1'-0"W1 WALL TYPE 1 EXISTING LOG WALLW2 WALL TYPE 2 EXISTING LOG WALL WITH INTERIOR FINISH A601 _A601 DETAILS - TYP. ASSEMBLIES ISSUE: 98% SD HPC: 11.30.2015, 4.27.16, 12.8.16 PROGRESS: 5.16.16, 6.12.16, 6.23.16 11.2.16 HPC FINAL: 3.1.17 PERMIT SUBMITTAL : 3.22.17, 10.13.17 CONSTRUCTION: PROJECT # 1403 FILENAME: 1403 CONSULTANTS ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO 81611 CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE STRUCTURAL DESIGN 1040 MAIN ST CARBONDALE, CO 81623 CONTACT: SARA MICKUS (V) 970.510-0773 SURVEYOR HIRED GUN SURVEYING P.O. BOX 9 SNOWMASS, CO 81654 CONTACT: TOM YOKUM (V) (970) 923-2794 LANDSCAPE ARCHITECT LIFT STUDIO PO BOX 2748 ASPEN, CO 81612 CONTACT: RYAN VUGTEVEEN (V) (970) 404 5610 CIVIL ENGINEER WOODY CREEK ENGINEERING,LLC 520 E. HYMAN AVE. #201 ASPEN, CO 81612 CONTACT: JOSH RICE (V) 970 309 7130 SOILS ENGINEER CHURCH AND ASSOCIATES, INC 4501 WADSWORTH BLVD WHEATRIDGE, CO 80033 (V) 303 463 9317 MECHANICAL CONSULTANT DESIGN-BUILD BY GC GENERAL CONTRACTOR TBD. OWNERS FOX CROSSING PROPERTIES LOTS 4&6 LLC 6330 MERCER STREET HOUSTON, TEXAS 77005 CONTACT: JOHN MORTON VC: 713 299 7674 RACE ALLEY 541 RACE STREET ASPEN, CO 81611 PARCEL ID # 273707392007 1-1/2" = 1'-0"W3 WALL TYPE 3 GARAGE RAIN SCREEN EXTERIOR WALL 1-1/2" = 1'-0"W4 WALL TYPE 4 EXTERIOR WALL BELOW GRADE TYP 1-1/2" = 1'-0" W5 WALL TYPE 5 CONCRETE WALL TYPICAL (NON-THERMAL) 1-1/2" = 1'-0"W6 WALL TYPE 6 INTERIOR WALL - 1 HOUR 1-1/2" = 1'-0"W7 WALL TYPE 7 INTERIOR WALL 1-1/2" = 1'-0"W8 WALL TYPE 8 EXISTING LOG WALL WITH INTERIOR FURRING 1-1/2" = 1'-0" R1 ROOF TYPE 1 LOW SLOPE ROOF 1-1/2" = 1'-0"R2 ROOF TYPE 2 EXISTING ROOF 1-1/2" = 1'-0"R3 ROOF TYPE 3 EXISTING ROOF 1-1/2" = 1'-0"-- . NOT USED 1-1/2" = 1'-0" 8/17/18 nickt 8/17/18 nickt 8/17/18 nickt 8'-458" FINISH STAIR OPENING 3' - 0 " 2" 38" 3- 7 / 8 " 1 12" 38" 2" 312" 2" 3- 7 / 8 " 4-1/8" 4-1/8" ISSUE: PROGRESS: 98% SD HPC SUBMITTAL:4.27.2016, 12.9.16 PROGRESS: 5.16.2016 6.12.16 HPC: 3.1.17 PERMIT SUBMITTAL: 3.22.17, 10.13.17 CONSTRUCTION: PROJECT # 1403 FILENAME: 1403 CONSULTANTS ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE ENGINEERING 1040 MAIN STREET CARBONDALE, CO 81623 CONTACT: SARA MICKUS (970) 618 7708 SURVEYOR HIRED GUN SURVEYING P.O. BOX 9 SNOWMASS, CO 81654 CONTACT: TOM YOKUM (V) (970) 923-2794 LANDSCAPE ARCHITECT LIFT STUDIO LLC PO BOX 2748 ASPEN, CO 81612 CONTACT: RYAN V 970 404 5610 CIVIL ENGINEER WOODY CREEK ENGINEERING, LLC P.O. BOX 575 WOODY CREEK, CO 81656 CONTACT: JOSH RICE 970 309 7130 SOILS ENGINEER CHURCH AND ASSOCIATES, INC 4501 WADSWORTH BLVD WHEATRIDGE, CO 80033 (V) 303 463 9317 MECHANICAL CONSULTANT DESIGN BUILD GENERAL CONTRACTOR RUDD CONSTRUCTION 132 PARK AVENUE BASALT, CO 81621 CONTACT: SCOTT DURYEA (V) 970 618 7200 OWNERS FOX CROSSING PROPERTIES LOTS 4&6 LLC 6330 MERCER STREET HOUSTON, TEXAS 77005 CONTACT: JOHN MORTON RACE ALLEY 541 RACE STREET ASPEN, CO 81611 PARCEL ID # 273707392007 STAIR/EGRESS DETAILS A701 NORTH NORTH NORTH 8/17/18 nickt LA LB LC LE LG 008 009 010 009 ISSUE: PROGRESS: 98% SD HPC SUBMITTAL:4.27.2016, 12.9.16 PROGRESS: 5.16.2016 6.12.16 HPC: 3.1.17 PERMIT SUBMITTAL: 3.22.17, 10.13.17 CONSTRUCTION: PROJECT # 1403 FILENAME: 1403 CONSULTANTS ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE ENGINEERING 1040 MAIN STREET CARBONDALE, CO 81623 CONTACT: SARA MICKUS (970) 618 7708 SURVEYOR HIRED GUN SURVEYING P.O. BOX 9 SNOWMASS, CO 81654 CONTACT: TOM YOKUM (V) (970) 923-2794 LANDSCAPE ARCHITECT LIFT STUDIO LLC PO BOX 2748 ASPEN, CO 81612 CONTACT: RYAN V 970 404 5610 CIVIL ENGINEER WOODY CREEK ENGINEERING, LLC P.O. BOX 575 WOODY CREEK, CO 81656 CONTACT: JOSH RICE 970 309 7130 SOILS ENGINEER CHURCH AND ASSOCIATES, INC 4501 WADSWORTH BLVD WHEATRIDGE, CO 80033 (V) 303 463 9317 MECHANICAL CONSULTANT DESIGN BUILD GENERAL CONTRACTOR RUDD CONSTRUCTION 132 PARK AVENUE BASALT, CO 81621 CONTACT: SCOTT DURYEA (V) 970 618 7200 OWNERS FOX CROSSING PROPERTIES LOTS 4&6 LLC 6330 MERCER STREET HOUSTON, TEXAS 77005 CONTACT: JOHN MORTON RACE ALLEY 541 RACE STREET ASPEN, CO 81611 PARCEL ID # 273707392007 A703 LANDSCAPE DETAILS8/17/18 nickt GAGB GC GDGE GH GI GJ GK GF GG GS GT GV GS GR GQ GP GL GN GP GO GM LGLFLA LB LC LE GM SA SB WINDOW SCHEDULE A801 NOTES: WINDOW SCHEDULE NOTES: HISTORIC WINDOWS AND DOORS NOTES: DOOR SCHEDULE ISSUE: PROGRESS: 98% SD HPC SUBMITTAL:4.27.2016, 12.9.16 PROGRESS: 5.16.2016 6.12.16 HPC FINAL: 3.1.17 PERMIT: 3.22.17 CONSTRUCTION: PROJECT # 1403 FILENAME: 1403 CONSULTANTS ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO 81611 CONTACT: WILLIS PEMBER 970 920 1727 STRUCTURAL ENGINEER EVOLVE STRUCTURAL DESIGN 1040 MAIN ST CARBONDALE, CO 81623 CONTACT: SARA MICKUS 970.510-0773 SURVEYOR HIRED GUN SURVEYING PO BOX 9 SNOWMASS, CO 81654 CONTACT: TOM YOKUM 970 923-2794 LANDSCAPE ARCHITECT LIFT STUDIO PO BOX 2748 ASPEN, CO 81612 CONTACT: RYAN VUGTEVEEN 970 404 5610 CIVIL ENGINEER WOODY CREEK ENGINEERING,LLC 520 E. HYMAN AVE. #201 ASPEN, CO 81612 CONTACT: JOSH RICE 970 309 7130 SOILS ENGINEER CHURCH AND ASSOCIATES, INC 4501 WADSWORTH BLVD WHEATRIDGE, CO 80033 303 463 9317 MECHANICAL CONSULTANT DESIGN-BUILD BY GC GENERAL CONTRACTOR TBD. OWNERS FOX CROSSING PROPERTIES LOTS 4&6 LLC 6330 MERCER STREET HOUSTON, TEXAS 77005 CONTACT: JOHN MORTON RACE ALLEY 541 RACE STREET ASPEN, CO 81611 PARCEL ID # 273707392007 WINDOW SCHEDULE A801 8/17/18 nickt ISSUE: 98% SD HPC: 11.30.2015, 4.27.16, 12.8.16 PROGRESS: 5.16.16, 6.12.16, 6.23.16 11.2.16 HPC FINAL: 3.1.17 PERMIT: 3.22.17, 10.13.17 CONSTRUCTION: PROJECT # 1403 FILENAME: 1403 CONSULTANTS ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO 81611 CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE STRUCTURAL DESIGN 1040 MAIN ST CARBONDALE, CO 81623 CONTACT: SARA MICKUS (V) 970.510-0773 SURVEYOR HIRED GUN SURVEYING P.O. BOX 9 SNOWMASS, CO 81654 CONTACT: TOM YOKUM (V) (970) 923-2794 LANDSCAPE ARCHITECT LIFT STUDIO PO BOX 2748 ASPEN, CO 81612 CONTACT: RYAN VUGTEVEEN (V) (970) 404 5610 CIVIL ENGINEER WOODY CREEK ENGINEERING,LLC 520 E. HYMAN AVE. #201 ASPEN, CO 81612 CONTACT: JOSH RICE (V) 970 309 7130 SOILS ENGINEER CHURCH AND ASSOCIATES, INC 4501 WADSWORTH BLVD WHEATRIDGE, CO 80033 (V) 303 463 9317 MECHANICAL CONSULTANT DESIGN-BUILD BY GC GENERAL CONTRACTOR TBD. OWNERS FOX CROSSING PROPERTIES LOTS 4&6 LLC 6330 MERCER STREET HOUSTON, TEXAS 77005 CONTACT: JOHN MORTON VC: 713 299 7674 RACE ALLEY 541 RACE STREET ASPEN, CO 81611 PARCEL ID # 273707392007 LOWER FLOOR ELECTRICAL PLAN E201 NORTH 8/17/18 nickt ISSUE: 98% SD HPC: 11.30.2015, 4.27.16, 12.8.16 PROGRESS: 5.16.16, 6.12.16, 6.23.16 11.2.16, HPC 3.1.17 PERMIT: 3.22.17, 10.13.17 CONSTRUCTION: PROJECT # 1403 FILENAME: 1403 CONSULTANTS ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO 81611 CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE STRUCTURAL DESIGN 1040 MAIN ST CARBONDALE, CO 81623 CONTACT: SARA MICKUS (V) 970.510-0773 SURVEYOR HIRED GUN SURVEYING P.O. BOX 9 SNOWMASS, CO 81654 CONTACT: TOM YOKUM (V) (970) 923-2794 LANDSCAPE ARCHITECT LIFT STUDIO PO BOX 2748 ASPEN, CO 81612 CONTACT: RYAN VUGTEVEEN (V) (970) 404 5610 CIVIL ENGINEER WOODY CREEK ENGINEERING,LLC 520 E. HYMAN AVE. #201 ASPEN, CO 81612 CONTACT: JOSH RICE (V) 970 309 7130 SOILS ENGINEER CHURCH AND ASSOCIATES, INC 4501 WADSWORTH BLVD WHEATRIDGE, CO 80033 (V) 303 463 9317 MECHANICAL CONSULTANT DESIGN-BUILD BY GC GENERAL CONTRACTOR TBD. OWNERS FOX CROSSING PROPERTIES LOTS 4&6 LLC 6330 MERCER STREET HOUSTON, TEXAS 77005 CONTACT: JOHN MORTON VC: 713 299 7674 RACE ALLEY 541 RACE STREET ASPEN, CO 81611 PARCEL ID # 273707392007 GROUND FLOOR ELECTRICAL +RCP E202 NORTH 8/17/18 nickt 8/17/18 nickt 8/17/18 nickt 8/17/18 nickt REINFORCED CONCRETE 1.All concrete design is based on the "Building Code Requirements for Reinforced Concrete", ACI 318, latest edition, and associated Commentary (ACI 318R). 2. All structural concrete shall have a minimum compressive strength at 28 days of 3000 psi in accordance with ASTM C39. All structural concrete exposed to freeze-thaw cycles shall have a maximum w/cm ratio of 0.45 and a minimum 28 day compressive strength of 4500 psi. Stained or polished concrete floor slabs are recommended to be a minimum of 4000 psi with low pozzolanic material ratios. 3. All concrete shall be consolidated using mechanical vibrators. 4. All concrete work shall conform to the requirements of the IBC and ACI Standard 318, latest edition, of the American Concrete Institute (ACI), unless shown or noted otherwise on these drawings. 5. Aggregate shall conform to ASTM C33. 6. Cement shall be ASTM C150, Type I or Type II modified. 7. Concrete shall be placed in accordance with ASTM C94 and ACI Standard 304. 8. All embedded items shall be placed accurately and secured prior to beginning concrete placement. 9. Construction joints shall be located so as not to impair the strength of the structure. Construction joints shall comply with ACI 318, unless noted otherwise. 10. Concrete mix designs shall be submitted to the Architect & S.E.O.R. for approval prior to placement of any concrete. 11. Reinforcement and embedded items shall be free of excessive scale, rust, dirt, grease, & all or any other substance that will impair bond with concrete. STRUCTURAL GENERAL NOTES GENERAL 1.All construction shall conform to the 2015 edition of the International Building Code (IBC), and the City of Aspen amendments. 2. Details not specifically shown on these drawings shall be similar to details for like construction as shown on these drawings. 3. The Contractor shall verify all dimensions and conditions at the job site, and shall report any discrepancies to the Architect and Structural Engineer of Record (S.E.O.R.) before proceeding with work. 4. Refer to Architectural drawings for dimensions and other information not specifically shown on Structural Drawings. Dimensions shown are approximate and are provided as an aid in interpreting the drawings and must be verified with the Architectural drawings. In the event of conflict, dimensions shown on the Architectural drawings shall govern. Notify the S.E.O.R. of any discrepancies prior to constructing the impacted portions of the work. Scaled dimensions shall not be used. 5. No structural members shall be cut, notched or otherwise penetrated unless specifically approved by the S.E.O.R. in advance or as shown on these drawings. 6. Provide openings, curbs, framing, supports and attachments for items as indicated on Architectural, Mechanical, Electrical or other drawings included in the Construction Documents. 7. Where these General Notes and typical details are in conflict with the Specifications, these Notes and Details shall govern. REINFORCING STEEL 1. All detailing, fabrication, and placement of reinforcing steel shall be in accordance with the ACI Manual of Concrete Practice. 2. Except where otherwise noted on the Drawings, reinforcing bars shall conform to ASTM Specification A615 and shall be Grade 60. Ties and field-bent bars as noted on plan shall be Grade 40. All reinforcing bars to be welded shall conform to ASTM A706. 3. Welded wire fabric reinforcement shall conform to ASTM A185 and shall be sheet-type; roll-type is not acceptable. 4. Coverage for reinforcing bars shall be in accordance with the requirements of the IBC, the ACI Standard 318 and in the Table below, unless shown otherwise on the Drawings. 5. Lap splices for reinforcing bars shall be 57 bar diameters (24" minimum) for concrete reinforcement and 72 bar diameters (36" minimum) for masonry reinforcement unless shown otherwise on the Drawings. Wire bars together at laps or splices. Stagger laps in adjacent horizontal bars a minimum of the required splice length. Hooks shall be ACI standard hooks unless shown otherwise. Welded wire fabric shall be spliced by lapping a minimum of 12 inches, or (2) cross wires, whichever is greater. MANUFACTURED WOOD PRODUCTS 1. Manufactured wood I-joists shall be installed in accordance with the manufacturer's recommended details for blocking, bracing, bearing and connections. See plan for size, depth and product designations. Any alternate products shall be submitted to the engineer for written approval prior to construction. 2. Laminated Veneer Lumber (LVL) beam & column plies shall be 1 3 4" in width with number of plies and depths as noted on plan. LVL shall have the following minimum working stresses: Fc pll=2,510 psi, Fb=2,600 psi, Fv=285 psi, E=2,000,000 psi. 3. Laminated Strand Lumber (LSL), beams (13 4" min) and rimboard (11 4" min) shall be as noted on plan, with the following minimum working stresses: Fc pll=1,400 psi, Fb=1,700 psi, Fv=400 psi, E=1,300,000 psi. 4. Versa-Stud (1 1 2" min) shall be noted on plan, with the following minimum working stresses: Fc pll=3,000 psi, Fb=2,400 psi, E=1,700,000 psi. 5. Parallel Strand Lumber (PSL) beams shall be as noted on plan with the following minimum working stresses: Fb=2,900 psi, Fv=290 psi, E=2,000,000 psi. 6. Parallel Strand Lumber (PSL) columns shall be as noted on plan with the following minimum working stresses: Fc pll=2,500 psi, Fb=2,400 psi, Fv=190 psi, E=1,800,000 psi. 7. Glulam (GL) beams shall be as noted on plan with the following minimum working stresses: 24F-V4, Fb(tension zone)=2,400 psi, Fv=240 psi, E=1,800,000 psi. All mult-span beams, including cantilever conditions, shall be 24F-V8 unless noted otherwise in the drawings. 8. Manufactured wood products as noted above shall be installed per manufacturer's specifications. 9. Manufactured wood products in contact with concrete or masonry foundation or exposed to exterior conditions shall be treated per manufacturer's specifications. 10. Wood manufactured products other than those noted, which have I.C.B.O. approval, may be used with approval by the engineer of record. Substitutions made by the Owner or Contractor shall include all connection hardware as required for sizes used, and shall have equivalent load ratings as those called for on the Drawings. STRUCTURAL ERECTION AND BRACING REQUIREMENTS 1. The Structural Drawings illustrate the completed structure with all elements in their final positions, properly supported and braced. 2. The Contractor, in the proper sequence, shall provide shoring and bracing as required during construction to achieve the final completed structure. Design, sequencing, location, placement, etc. of bracing and shoring is the responsibility of the Contractor. 3. The Contractor shall be responsible for the safety of the building and workers during construction. The Contractor shall comply with all applicable safety regulations. BACKFILLING 1. Contractor shall not backfill against basement and/or retaining walls until all supporting elements (ex: concrete slabs and/or floor framing) are in place and securely anchored, or until adequate temporary shoring is installed. 2. Contractor shall verify type of backfill material with Geotechnical Engineer prior to backfilling. STRUCTURAL STEEL 1. All detailing, fabrication, and erection of structural and miscellaneous steel shall be in accordance with the requirements of the American Institute of Steel Construction (AISC) Code of Standard Practice, latest edition, and the American Welding Society (AWS) Specifications. 2. All structural steel rolled shapes, except angles and plates, shall conform to ASTM A992, 50 ksi. 3. Angles, channels & plates shall conform to ASTM A36, 36 ksi, unless otherwise noted on the Drawings. 4. Pipes shall conform to ASTM A53, Grade B, 35 ksi. 5. Tube shapes (HSS) shall conform to ASTM A500, Grade B, rectangular shapes = 46 ksi & round shapes = 42 ksi. 6. All bolts for steel-to-steel connections shall conform to ASTM A325, unless otherwise noted on the Drawings. 7. All anchor bolts shall conform to ASTM F1554 Gr. 36, unless otherwise noted on the Drawings. 8. All shear studs shall conform to ASTM A108 & shall be welded to steel beams for full shear capacity. 9. All welding shall be in accordance with the requirements of the IBC and the Structural Welding Code, AWS D1, latest edition, by the American Welding Society. Shop welding shall be performed in shops approved by the Building Official, per IBC Section 1704.2.5. Welding shall be done using E70XX electrodes, unless noted otherwise on the Drawings. 10. Expansion bolts and epoxy anchors called for on the Drawings shall be Hilti or approved equivalent, with embedment as shown on the Drawings. Expansion bolts shall be Hilti Kwik Bolt 3 & Epoxy shall be Hilti HIT-HY 200 or approved equivalent, unless otherwise noted on the Drawings. 11. Powder actuated fasteners shall be Hilti DNI or approved equivalent, with full penetration into steel members, unless otherwise noted on the Drawings. 12. Steel, including bolts & anchors, in contact with earth, or as otherwise noted on the Drawings, shall be hot dip galvanized or prime painted. Do not paint within 3" of field welds until welds are completed. FASTENER AT NEAR FACE FASTENER AT FAR FACE (3-PLY & 4-PLY ONLY) PLY TO PLY CONNECTION 3-PLY2-PLY 2 ROWS 10d NAILS @ 12"o.c.ONE FACE EA FACE PLY TO PLY CONNECTION 3-PLY2-PLY 2 ROWS 12d NAILS @ 12"o.c.ONE FACE EA FACE 2" 12"/24"o.c.2" PLY TO PLY CONNECTION 3-PLY2-PLY 3 ROWS 16d NAILS @ 12"o.c.ONE FACE EA FACE 4-PLY EA FACE2 ROWS 1/4"x6" SDS SCREWS @ 24"o.c. 4-PLY 3 ROWS 1/4"x6" SDS SCREWS @ 24"o.c.EA FACE FOR COLUMNS OVER 3-PLY, ATTACH EACH ADDITIONAL PLY w/ (2) ROWS OF 10d NAILS @ 12"o.c. SAWN LUMBER (2" NOM. THICKNESS) CONNECTION SCHEDULE LVL 1 3/4" THICK, MEMBER WIDTH < 14" CONNECTION SCHEDULE LVL 1 3/4" THICK, MEMBER WIDTH > = 14" CONNECTION SCHEDULE 2-PLY MEMBER 3-PLY MEMBER 4-PLY MEMBER ELEVATION TYP MULTIPLE PLY BEAMS & COLUMNS SCALE: N.T.S. 3 S0.01 GROUT & ADHESIVE 1. All grout beneath column base plates, or steel beams at bearing shall be non-metallic, non-shrink high strength grout by "Five Star, "Embeco", or approved equal installed to manufacturer's specifications. 2. All structural construction adhesive specified shall be Loctite PL Premium Fast Grab or approved equal & shall be installed to manufacturer's specifications. 1. FLOOR SHEATHING (AND FLAT ROOF SHTG) SHALL BE AS FOLLOWS: WOOD STRUCTURAL PANELS CERTIFIED BY THE APA FOR USE AS FLOOR SHEATHING, RATED STURD-I FLOOR, 24" o.c, 23 32" THICK, T & G OR 118" WARMBOARD-S. FLOOR SHEATHING SHALL BE GLUED AND FASTENED TO FLOOR JOISTS & BEAMS USING ADHESIVES CONFORMING TO APA SPECIFICATION AFG-01 AND APPLIED IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. REMOVE WATER, DUST AND DEBRIS FROM JOISTS. APPLY GLUE TO JOISTS & BEAMS AND COMPLETE ALL FASTENING BEFORE GLUE SETS. FLOOR SHEATHING USED AT EXTERIOR DECKS SHALL BE LABELED "EXTERIOR" OR "EXPOSURE 1". 2. ROOF SHEATHING SHALL BE AS FOLLOWS: WOOD STRUCTURAL PANELS CERTIFIED BY THE APA FOR USE AS ROOF SHEATHING, LABELED "EXTERIOR" OR "EXPOSURE 1", RATED SHEATHING, 40/20, 5/8" THICK 3. FLOOR AND ROOF SHEATHING LAYOUT: 3-SPAN CONTINUOUS - MIN, PERP TO FRAMING MEMBERS FRAMING MEMBERS TYP FLOOR & ROOF SHEATHING SCALE: NTS 1 BRACED WALL PANELS 1. All bearing walls, including unlabeled, hatched BWP's, shall be continuously sheathed as Typical Exterior or Interior Panels, accordingly. 2. Typical Exterior Panels shall be 7 16" APA rated OSB or plywood attached to studs w/ 8d common or galvanized box nails (13 8" stud penetration) @ 6"o.c. at panel edges & 12"o.c. at intermediate supports. Block all panel edges. 3. Typical Interior Panels shall be 5 8" gypsum board, both sides of wall, attached to studs w/ 6d cooler nails, 0.120 x 13 4", min 3 8" head (or No. 6 11 4" Type S or W screws), spaced at 4"o.c. at all supports, studs & plates. Studs shall be spaced @ 24"o.c. max @ panels. 4. All hatched BWP's are critical to the current lateral force resisting system design. They shall not be modified. 5. Special BWP's, holdown straps & anchors, as required, are denoted per plans and shall be constructed per schedules shown on these drawings. 2'-0" MIN LAP - U.N.O. WOOD AND TIMBER FRAMING 1. All wood and heavy timber construction shall conform to the American Institute of Timber Construction (AITC) and National Design Specification (NDS) Standards, latest edition. 2. Structural framing lumber shall be at a minimum, as noted below, unless noted otherwise, and shall have a maximum moisture content of 19% at time of delivery. 3. Provide solid blocking at supports between joists and rafters. Within floor joist spaces beneath solid or built-up posts, provide solid blocking with area same as post above. 4. All plywood shown on these drawings shall be minimum C-D grade with exterior glue in accordance with DOC PS 1 and comply with IBC section 2304. 5. Sill plates shall be of naturally durable wood, or Zinc Borate treated LSL or Douglas Fir-Larch per IBC Section 2304.12 with Fc perp = 625 psi, minimum and shall be protected for dry use. 6. All wood framing shall be preservative pressure treated when in contact with concrete or masonry foundation or exposed to exterior conditions. All fasteners used to connect pressure-treated wood shall be hot-dipped galvanized (HDG) or stainless steel. 7. Except as noted otherwise, provide minimum nailing as specified in IBC Table 2304.10.1 Structural nailing shall be with common nails, unless otherwise noted on the Drawings. Nails exposed to weather shall be galvanized. Nails used to connect preservative treated wood shall be hot dipped galvanized (HDG) or stainless steel. 8. Metal timber connectors shall be Simpson Strong-Tie or equivalent. Hardware specified is for specific member size & manufacturer as show on the structural drawings. Hanger slope, skew & top flange shall be designated by the contractor as required. Simpson connectors for preservative treated wood or connectors in contact with concrete shall be ZMAX or HDG, or as otherwise recommended by specific connector supplier. Install all connectors in accordance with manufacturer's instructions for maximum rated loads. 9. Bolts used as timber-to-steel or timber-to-timber connectors shall be ASTM A307 unless noted otherwise on the Drawings. Bolts shall be installed in accordance with the requirements of the latest edition of the National Design Specification for Wood Construction (NDS) by the National Forest Products Assoc. Bolts used to connect pressure-treated wood shall be HDG or stainless steel. 10. Lag screws shall be ASTM A307. Holes for lag screws shall be bored the same depth and diameter as the bolt shank. The remaining depth of penetration shall be bored per NDS requirements. Lag screws used to connect pressure-treated wood shall be HDG or stainless steel. 11. Provide malleable iron washers or equivalent cut plate washers under all nuts, bolts or lag screw heads which bear on wood. 12. Wood screws shall be steel per NDS requirements. Pre-drill holes to prevent splitting as recommended in the NDS. 13. Wood members shall be cut or notched only as shown on the Structural Drawings. 14. Provide cross bridging, solid bridging or other lateral support for all framing members in accordance with the requirements of IBC Section 2308. 15. Except where more stringent construction is shown on the Drawings, wood construction shall comply with the requirements of the IBC, latest edition, as a minimum. SHEATHING NAILING SHEATHING APPLICATION FASTENERS NAIL SPACING COMMENTS @ INTERMEDIATE SUPPORTS @ PANEL EDGES WOOD FLOOR 10d COMMON (0.148 Ø)12"6" U.N.O.GLUED (SEE NOTE 1) WOOD ROOF 8d COMMON (0.131 Ø)12"6"- DBL 2x TOP PL TYP U.N.O. (2) 10d @ CORNER & INTERSECTION LAPS 10d COMMON @ 24"o.c. (2) 10d ADD'L (8) 10d COMMON MIN BTWN SPLICES MINIMUM CONCRETE COVER FOR REINFORCEMENT1 CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" CONCRETE EXPOSED TO EARTH OR WEATHER No. 6 thru No. 18 bars 2" No. 5 bar, W31 or D31 wire, and smaller 11 2" CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND Slabs, Walls, Joists:No. 14 and No. 18 bars 1 1 2" No. 11 bar and smaller 3 4" Beams, Columns:Primary reinforcement, ties, stirrups, spirals 112 1.Minimum concrete cover specified or for cast-in-place, nonprestressed concrete TYPE SPECIES GRADE Fb (MIN) Existing 2x structural Joists, Rafters & Headers Hem Fir No. 2 850 psi 2x Structural Joists, Rafters & Headers Douglas Fir-Larch No. 2 900 psi 2x Studs, Posts & Plates Douglas Fir-Larch No. 2 900 psi Versa-Stud 1.7E 2,400 psi Plates Douglas Fir-Larch No. 2 900 psi LSL 1.3E 1,700 psi Stringers, Beams & Posts (4x)Douglas Fir-Larch No. 1 1,000 psi Stringers, beams (6x & greater)Douglas Fir-Larch No. 1 1,350 psi Posts (6x & greater)Douglas Fir-Larch No. 1 1,200 psi DESIGN LOADS 1. ROOF LOADS 1.1. Dead Load ............................. 15 psf 1.2. Live Load (Snow).................... 75 psf* 2. FLOORS LOADS 2.1. Dead Load ............................. 20 psf 2.2. Live Load ............................... 40 psf 3. LATERAL LOADS 3.1. Seismic Design Category....... C 3.2. Basic Wind Speed ................. 115 mph 3.3. Exposure Category ............... B 3.4. Importance Factor ................. 1 * No duration of load increase was used in design FOUNDATIONS 1. Concrete foundations are designed based on the following soil parameters as provided in the Geotechnical Engineering Study prepared for Fox Crossing Development at Gibson Avenue & Lone Pine Street, Aspen, Colorado, Project No. CO51128, by Intec Church and Associates, Inc. dated September 6, 2005. 1.1. Density = 120 pcf (Assumed) 1.2. Allowable Bearing Pressure = 2,500 psf 1.3. Lateral At-Rest Earth Pressure = 60 pcf (Properly compacted backfill) 1.4. Lateral Active Earth Pressure = 50 pcf (Properly compacted backfill) 1.5. Lateral Passive Earth Pressure = 350 pcf (Compacted fill, Ultimate) 1.6. Coefficient of Friction for Footing = 0.40 (Assumed, Ultimate) 1.7. Frost Depth = 42" min 2. Soils conditions and types shall be verified by a representative of a qualified Geotechnical Engineer (employed by Owner) during excavation. 3. Proper surface and below grade perimeter drainage shall be installed per Civil & Geotechnical Engineers to relieve foundations from hydrostatic pressures. 4. It is the responsibility of the Contractor to review the Geotechnical Engineer's recommendations and notify the Architect and/or S.E.O.R. if any changes to the design are required prior to start of construction. SPECIAL INSPECTION 1. The owner shall employ a special inspector per IBC Chapter 17. The special inspector shall submit a copy of all his reports to the Owner, Architect, Structural Engineer and the Building Department. When the work is completed, the special inspector shall submit a final signed report stating whether the work was, to the best of his knowledge, in conformance with the approved set of plans and specifications and the applicable workmanship provisions of the building code. The structural engineer of record will make visits to the site to observe general compliance with the approved structural plans, specifications and change orders. The contractor shall coordinate with the special inspector in order to ensure that the special inspection as indicated below can be performed with minimal impact to the project schedule. 2. Special inspection is required for the following types of work. Refer to Chapter 17 of the 2015 IBC for additional testing and specific requirements. 2.1. All cast-in-place concrete work & reinforcing placement, except nonstructural concrete (periodic). 2.2. All masonry construction (periodic per IBC 1705.4). 2.3. All bolts and embeds in concrete (continuous if wet stabbed, periodic if tied). 2.4. All shop and field welding (periodic). 2.5. All high-strength bolted connections (periodic). SHOP AND ERECTION DRAWINGS 1. The Contractor shall furnish (2) sets of shop and erection drawings for review to the Architect and Structural Engineer of Record prior to fabrication for the following items: 1.1. Structural steel 1.2. Concrete and masonry reinforcing steel 1.3. Concrete mix designs 1.4. Glazing and intermediate structure per manufacturer for large areas of wall 2. The manufacture, fabrication or erection of above noted items prior to written review by the Architect and Structural Engineer of Record is at the sole risk of the Contractor. ATTACH ALL KING & TRIM STUD PLIES PER TYP MULTIPLE PLY BM & COL DETAIL ATTACH ALL HEADER PLIES PER TYP MULTIPLE PLY BM & COL DETAIL A35 OR LS50 CLIP @ KING STUD TO TOP & BOT PL's @ WALL OPNG WIDTH > 3'-6" & (2) A35 OR LS50's @ WIDTH > 7'-0" - TYP U.N.O. 2x SILL PL - USE (2) 2x PL's w/ A35 EA END @ EXT WALL OPNG 8'-0" & GREATER - TYP (1) 2x6 TRIM STUD MIN, TYP U.N.O. PER PLAN (2) 2x6 HDR MIN, TYP U.N.O. PER PLAN (2) 16d COMMON, END NAIL OR (4) 8d COMMON TOENAIL, EA STUD - TYP BOT/SILL PL - SEE PLAN NOTES OR SPECIFIC DETAILS FOR ANCHOR BOLT SIZE & SPACING 2x6 STUDS @ 16"o.c. PER PLAN & DETAILS - U.N.O 2x SOLID BLKG REQ'D AT CEILING LINES & AT ALL EDGES OF EXT WALL SHTG (1) 2x6 KING STUD MIN, TYP U.N.O. PER PLAN (4) 16d COMMON (2) 16d COMMON, END NAIL, TOP PL TO EACH STUD - TYP 2 SCALE: 3 4" = 1'-0" TYPICAL WALL FRAMING DETAIL A.F.F.______ABOVE FINISH FLOOR ABV_______ABOVE ADD'L______ADDITIONAL ADJ________ADJUSTABLE ALT________ALTERNATE A.C.I._______AMERICAN CONCRETE INSTITUTE A.P.A.______AMERICAN PLYWOOD ASSOC. AB_________ANCHOR BOLT ARCH______ARCHITECT(URAL) BM_________BEAM BLW_______BELOW BRG_______BEARING BTWN______BETWEEN BLKG______BLOCKING B or BOT____BOTTOM B.O.________BOTTOM OF B.O.W._____BOTTOM OF WALL BWP_______BRACED WALL PANEL BLDG______BUILDING CANT'D_____CANTILEVERED C.I.P._______CAST-IN-PLACE CLR________CLEAR CNTRD_____CENTERED CL_________CENTERLINE CW________CLOCKWISE COL_______COLUMN C.J.P.______COMPLETE JOINT PENETRATION CONC______CONCRETE C.M.U.______CONCRETE MASONRY UNIT CONN______CONNECTION CONST_____CONSTRUCTION CONT______CONTINUOUS CONTR_____CONTRACTOR C.J. _______CONTROL JOINT CCW_______COUNTER-CLOCKWISE DIAG_______DIAGONAL DL_________DEAD LOAD DEFL_______DEFLECTION D.B.A.______DEFORMED BAR ANCHOR D.W.F.______DEFORMED WIRE FABRIC E.F.________EACH FACE E.N.________EDGE NAILING EL_________ELEVATION ELEV_______ELEVATOR EMBED_____EMBEDMENT EQ_________EQUAL EQUIV______EQUIVALENT EXISTG/(E)__EXISTING EXP________EXPANSION EXT________EXTERIOR F.D.________FLOOR DRAIN FLG________FLANGE FTG________FOOTING FDN________FOUNDATION GA_________GAUGE/GAGE GALV______GALVANIZED, HOT DIP G.C._______GENERAL CONTRACTOR GL_________GLUE-LAMINATED MEMBER G.B.________GRADE BEAM HGR_______HANGER H.A.S.______HEADED ANCHOR STUD HDR_______HEADER HT_________HEIGHT HSS________HOLLOW STRUCTURAL STEEL HK_________HOOK HORIZ______HORIZONTAL I.F._________INSIDE FACE INT________INTERIOR IBC________INTN'L BUILDING CODE IRC________INTN'L RESIDENTIAL CODE ISO________ISOLATION JT_________JOINT JST________JOIST K__________KING KSI________KIPS PER SQUARE INCH LVL________LAMINATED VENEER LUMBER LT_________LIGHT LL_________LIVE LOAD LOC________LOCATION LLH________LONG LEG HORIZONTAL LLV________LONG LEG VERTICAL MFR_______MANUFACTURER M.O._______MASONRY OPENING MAT'L______MATERIAL MAX_______MAXIMUM MECH______MECHANICAL MTL________METAL MISC_______MISCELLANEOUS MIN________MINIMUM M.F. MOMENT FRAME N.S.________NOT SHOWN NTS________NOT TO SCALE o.c.________ON-CENTER OPNG______OPENING O.H._______OPPOSITE HAND OSB_______ORIENTED STRAND BOARD O.F.________OUTSIDE FACE PLL________PARALLEL PSL________PARALLEL STRAND LUMBER PEN________PENETRATION PERP______PERPENDICULAR PLCS_______PLACES PL_________PLATE PLWD______PLYWOOD PLF________POUNDS PER LINEAR FOOT PSF________POUNDS PER SQUARE FOOT P.A.F.______POWER-ACTUATED FASTENER P.C.________PER CAST P.E.________PRE-ENGINEERED P.T.________PRESSURE TREATED R__________RADIUS RE:________REFER TO REINF______REINFORCING/MENT REQ'D______REQUIRED R.D.________ROOF DRAIN R.S.________ROUGH SAWN SCHED_____SCHEDULE SHTG______SHEATHING SHT________SHEET SIM________SIMILAR S.O.G.______SLAB ON GRADE SP_________SPACE (ING) SPECS_____SPECIFICATIONS STAG______STAGGERED S.S.________STAINLESS STEEL STD________STANDARD STL________STEEL STRUCT____STRUCTURAL S.E.O.R.____STRUCTURAL ENGINEER OF RECORD SYM_______SYMMETRICAL T&B________TOP AND BOTTOM T.O.________TOP OF T.O.M.______TOP OF MASONRY T.O.S.______TOP OF STEEL T.O.W._____TOP OF WALL T.P.________TOP PLATE T&G_______TONGUE AND GOOVE T__________TRIMMER TS_________TUBE STEEL COLUMN TYP________TYPICAL U.B.C.______UNIFORM BUILDING CODE U.N.O.______UNLESS NOTED OTHERWISE V.I.F._______VERIFY IN FIELD VERT______VERTICAL WT________WEIGHT WWF_______WELDED WIRE FABRIC w/_________WITH WD________WOOD W.P._______WORK POINT ABBREVIATIONS TYPICAL FRAMING CONNECTION SCHEDULE (MINIMUM U.N.O.)1, 2 NAILING TYPE Joists or Rafters to T.O. Double Top Plate, Sill Plate or Beam (3) 10d Toenail Rim Joist or Structural Fascia to Joists, Rafters (2) 16d, (1) T&B End Nail Sole Plate to Sill Plate (3) 10d @ 16"o.c.Face Nail Sole Plate to Joist, Rim Joist, Beam or Blkg - Typ (2) 16d @ 16"o.c.Face Nail Sole Plate to Joist, Rim Joist, Beam or Blkg at BWP (3) 16d @ 16"o.c.Face Nail Double Studs, Built-up Corner Studs, Trim Studs to King Studs1 Per Typ Detail Rim Joist to Top Plate 8d @ 6"o.c.Toenail Blkg Btwn Rafters & Joists to Top Plate, Sill Plate or Beam 8d @ 6"o.c. (3) min per block Toenail 2x Decking to Joists (2) 10d each joist Face Nail 1. Refer to Typical Multiple Ply Beams & Columns Detail for additional information. 2. Refer to Typical Framed Wall Detail for additional information. S0.01S0.01 EXISTING FLOOR JOIST OR ROOF RAFTER, U.N.O. EXISTING FLUSH BEAM SUPPORTING FRAMING EXISTING DROPPED BEAM SUPPORTING FRAMING EXISTING HEADER SUPPORTING FRAMING STRUCTURAL SYMBOLS LEGEND EXISTING MASONRY CONSTRUCTION NEW CONCRETE FOUNDATION WALL & FOOTING EXISTING CONCRETE FOUNDATION WALL & FOOTING EXISTING LEDGER SUPPORTING FRAMING EXISTING BEARING WALL TO BE REMOVED EXISTING BEARING WALL ROOF OR FLOOR MEMBER SPAN AND LENGTH ARROWS DESIGNATE BEARING LOCATIONS ROOF OVERFRAMING PER TYPICAL DETAIL / S0.0 X STEEL OR WOOD COLUMN WHICH SUPPORTS FRAMING OR LOADS FROM ABOVE SEE WALL FRAMING NOTES FOR MIN SIZE, NUMBER, AND TYPE FLOOR JOIST OR ROOF RAFTER, U.N.O. JOIST HANGER OR BEAM TO BEAM CONNECTION RE: HANGER SCHEDULE FOR CONN, U.N.O. FLUSH BEAM SUPPORTING FRAMING VERTICAL STEP IN FLOOR WOOD STUD BEARING WALL ABOVE NON-BEARING WOOD STUD WALL BELOW FRAMING REVISION CLOUD INDICATING A REVISED ITEM REVISION NUMBER CORRESPONDS WITH REVISIONS IN TITLE BLOCK STEEL OR WOOD COLUMN FROM ABOVE OR B/W BEAMS WHICH IS SUPPORTED ON FRAMING, MIN WIDTH TO MATCH SUPPORTED FRAMING, U.N.O. EXISTING ROOF OR FLOOR MEMBER SPAN AND LENGTH ARROWS DESIGNATE BEARING LOCATIONS DROPPED BEAM SUPPORTING FRAMING HEADER SUPPORTING FRAMING WALL STEP, POINTS IN DIRECTION OF DOWN MASONRY CONSTRUCTION LEDGER SUPPORTING FRAMING 2x WOOD STUD BEARING WALL BELOW FRAMING MOMENT CONNECTION INDICATES LOCATION OF EXTERIOR AND INTERIOR BRACED WALL PANELS (BWP's). WHERE BWP's ARE NOT DIMENSIONED, EXTEND BETWEEN WALL OPENINGS OR CORNERS AS SHOWN ON PLAN. SEE BRACED WALL PANEL NOTES / S0.0 HOLDOWN FRAMING STRAP OR FOUNDATION ANCHOR PER PLAN & SCHEDULE STEEL OR WOOD COLUMN FROM ABOVE WHICH IS CONTINUOUS TO LEVEL BELOW OR TO FOUNDATION JOIST JOIST JOIST JOIST Hx REVISIONS: DATE: 2/27/17 PROJECT # : 17.001C DRAWN BY : SE CHECKED BY : SE 03/21/17 PERMIT STRUCTURAL DESIGN www.evolvestruct.com 1040 Main Street Carbondale, CO 81623 (970) 510-0773 54 1 R A C E S T R E E T R E S I D E N C E AS P E N , C O L O R A D O GENERAL NOTES & TYPICAL DETAILS S0.01 S 8/17/18 nickt T.O. SLAB = 89'-71 4" 8" CONC BASEMENT WALL - TYP U.N.O. 8" CONC FOUNDATION WALL w/ #5 @ 12"o.c. EA WAY CTRD - TYP U.N.O. 10" CONC RETAINING WALL w/ #5 @ 8"o.c. VERT O.F. & #5 @ 12"o.c. HORIZ - TYP U.N.O. (SITE WALL LOCATIONS PER LANDSCAPE ARCH, TYP)8" CONC RETAINING WALL w/ #5 @ 12"o.c. EA WAY CTRD - TAPER T.O. WALL PER ARCH CONC BUTTRESS WALL w/ #5 @12"o.c. EA WAY E.F. - TYP @ 2 5 S5.01 4 S5.01 TYP 6 S5.01 TY P T.O. WALL 102'-6" T.O. FOOTING 100'-0" T.O. WALL 100'-11" T.O. WALL TAPERS & SLOPES T.O. WALL 102'-1" T.O. WALL 99'-11" T.O. WALL 92'-51 4" T.O. WALL 92'-91 4" T.O. FTG 91'-0" T.O. FTG 86'-11 1'-0" T.O. WALL 99'-5" T.O. WALL 99'-5" T.O. WALL 102'-11" T.O. LEDGE 99'-5" 16" W x 12" DP CONT GUARDRAIL FTG w/ (2) #5 CONT - TYP, DOWEL TO RET WALL w/ #4 @ 12"o.c. T.O. FTG 90'-0" T.O. FTG 90'-0" T.O. WALL 100'-91 4" T.O. WALL 99'-11"T.O. WALL 99'-5" T.O. WALL 99'-9" T.O. WALL 99'-9" T.O. WALL 99'-9" T.O. WALL 99'-9" T.O. WALL 100'-91 4" TYP U.N.O. T.O. FTG 94'-6" T.O. FTG 88'-111 4" T.O. FTG 94'-6" T.O. FTG 93'-0" T.O. FTG 97'-0" T.O. FTG 97'-0" T.O. FTG 93'-0" T.O. FTG 88'-111 4" T.O. WALL 101'-10" T.O. WALL 95'-0" T.O. FTG 86'-11 W10 COL AT EDGE OF LOW LANDING W10 CONT STAIR STRINGER T.O. WALL 100'-0" T.O. LEDGE 98'-6" T.O. WALL 102'-6" STL BM POCKET @ CHANNEL ABOVE - TYP @ 2 8" CONC BASEMENT WALL w/ #5 @ 10"o.c. VERT I.F. & #5 @ 12"o.c. HORIZ - TYP 8" CONC CRAWL SPACE WALL w/ #5 @ 12"o.c. EA WAY CTRD - TYP CONCRETE FOOTING SCHEDULE MARK SIZE REINFORCING FC16 1'-4" WIDE x 10" THICK CONT (2) #5 CONT, BOT FC18 1'-6" WIDE x 10" THICK CONT (2) #5 CONT, BOT FC22 1'-10" WIDE x 10" THICK CONT (3) #5 CONT, BOT FC24 2'-0" WIDE x 12" THICK CONT (3) #5 CONT, BOT FC16 - TYP INT FTG U.N.O. 3' - 4 1 4" FC24 - TYP @ BASEMENT WALL T.O. FTG 88'-111 4" T.O. FTG 88'-111 4" CONC CURB PER 4/S5.01 TYP - LOCATE PER ARCH 12" DP FTG AT STAIRS w/ #5 @ 12"o.c. T&B EA WAY FC16 - TYP @ GARAGE T.O. CURB 89'-71 4" TYPICAL SLAB ON GRADE 4" CONCRETE SLAB ON INSUL PER ARCH ON APPROVED NATIVE OR PREPARED SUBGRADE PER GEOTECH REPORT. REINFORCE SLAB WITH 6x6-W2.1xW2.1 WWF OR #3 @ 12"o.c EA WAY - CENTERED. PROVIDE 11 4" DEEP SAW-CUT CONTROL JOINTS @ 12'-0" o.c. MAX EACH WAY - TYP TYPICAL SLAB ON GRADE 4" CONCRETE SLAB ON INSUL PER ARCH ON APPROVED NATIVE OR PREPARED SUBGRADE PER GEOTECH REPORT. REINFORCE SLAB WITH 6x6-W2.1xW2.1 WWF OR #3 @ 12"o.c EA WAY - CENTERED. PROVIDE 11 4" DEEP SAW-CUT CONTROL JOINTS @ 12'-0" o.c. MAX EACH WAY - TYP 6 S5.01 TYP 11 ' - 7 1 4" 5'-0"26'-8"10'-1"22'-0" 3'-8" 11'-81 2" 17 ' - 8 " 10 ' - 8 " 8' - 4 1 2" 17 ' - 8 " 10 ' - 8 " 11'-8" 6'-8" 26'-8"5'-31 4" 12" DP x 6'-0" WIDE CONC FTG w/ #5 @ 16"o.c. T&B EA WAY TYP (3) SIDES 2'-7" 2' - 7 " 2 ' - 7 " 1'-10" 8" 2' - 7 1 4" 1'-0" 1' - 0 " 1' - 0 " 12" DP x 6'-0" WIDE CONC FTG w/ #5 @ 16"o.c. T&B EA WAY 4' - 4 1 2" 21 ' - 1 1 " 2' - 0 1 2" 8' - 4 1 2" 28 ' - 4 " 3' - 0 " 96.7° 90. 0 ° 8 3 . 2 ° FOUNDATION NOTES: 1. REFER TO SHEET S0.0 FOR GENERAL NOTES. 2. SEE FRAMING PLANS ABOVE FOR COLUMN & POST LOCATIONS & SIZES. 3. CONCRETE FOOTINGS & THICKENED SLABS SHALL BE PER PLAN & SCHEDULE ON S1.01. 4. ALL CONCRETE WALLS SHALL BE CENTERED ON FOOTINGS - U.N.O. 5. SEE 3/S5.01 FOR ALL CONCRETE REINFORCING STANDARD HOOKS AND BENDS. 6. PROPER SURFACE & BELOW GRADE PERIMETER DRAINAGE SHALL BE INSTALLED PER CIVIL & GEOTECHNICAL ENGINEERS TO RELIEVE FOUNDATION WALLS FROM HYDROSTATIC PRESSURES. 7. REFER TO SHEET S5.01 FOR TYPICAL CONCRETE DETAILS. 8. DO NOT PLACE BACKFILL AGAINST BASEMENT WALLS UNTIL ALL SUPPORTING ELEMENTS, INCLUDING MAIN LEVEL FLOOR SHEATHING, ARE IN PLACE AND SECURELY ANCHORED, OR UNTIL ADEQUATE TEMPORARY SHORING IS INSTALLED. 9. ALL DIMENSIONS SHALL BE COORDINATED WITH ARCHITECTURAL DRAWINGS & FIELD VERIFIED BY CONTRACTOR. 10. SOILS CONDITIONS TO BE VERIFIED IN FIELD AT OPEN HOLE BY SOILS ENGINEER PER FOUNDATIONS NOTES ON S0.01. 11. ANCHOR ALL SILL PLATES TO TOP OF CONCRETE WITH 5 8" DIAMETER ANCHOR BOLTS WITH MINIMUM 7" EMBEDMENT AT 6'-0" MAXIMUM, 2 ANCHORS MINIMUM PER PLATE, 4" FROM EACH END, U.N.O.. REFER TO BWP SCHEDULE FOR ATYPICAL A.B.'S AND SPACINGS, REFER TO PLANS ABOVE FOR LOCATIONS 12. REFER TO PLANS AND SCHEDULE FOR ALL HOLDOWN ANCHORS BETWEEN FRAMING AND INTO CONCRETE. REFER TO PLANS ABOVE FOR SPECIFICATIONS. 13. ISOLATE ALL SLABS-ON-GRADE FROM STRUCTURAL ELEMENTS WITH EXPANSION JOINT MATERIAL - U.N.O. FOUNDATION PLAN S1.01 REVISIONS: DATE: 2/27/17 PROJECT # : 17.001C DRAWN BY : SE CHECKED BY : SE 03/21/17 PERMIT STRUCTURAL DESIGN www.evolvestruct.com 1040 Main Street Carbondale, CO 81623 (970) 510-0773 54 1 R A C E S T R E E T R E S I D E N C E AS P E N , C O L O R A D O LOWER LEVEL FRAMING & FOUNDATION PLAN SCALE: 1 4" = 1'-0" A N S 8/17/18 nickt BATHROOM #3 CLOSET LAUNDRY HALL BEDROOM #2 BEDROOM #3 BATHROOM #2 STAIR FAMILY ROOM BEDROOM #1BATHROOM #1 (3 ) 1 1 7 8" L V L 117 8" TJI 560 @ 16"o.c. - TYP GREEN ROOF MEDIUM (100 PSF MAX) PER LANDSCAPE ARCH OVER STEEL PLATE 1 4 - BEAR PLATE 4" ON CONC @ ENDS 13 S5.02 TY P 4 S5.02 TY P 5 S5.01 (2 ) 1 1 7 8" L V L T.O. DECKING = 99'-91 2" 2x6 @ 16"o.c. DECK JOISTS - TYP P.T. 2x6 LEDGER w/ 5 8"Ø THREADED RODS @ 16"o.c. EMBED 6" IN EPOXY - TYP @ DECKS T.O. PLY = 98'-81 4" W10x39 - 2x NAILER PER 5/S5.02 T.O. STL = 99'-9" TYP U.N.O. W10x68 CONT STAIR STRINGER W10x68 - T.O. STL = 99'-81 2" W10x39 4" BM POCKET w/ P.T. 2x BRG PLATE TYP ITS 3 . 5 6 / 1 1 . 8 8 TYP ITS 3 . 5 6 / 1 1 . 8 8 STL BM POCKET w/ (2) 5 8"Ø THREADED RODS EMBED 6" IN EPOXY - SHIM END PL TO FACE OF CONC TYP @ 4 L4x4x3 8 LEDGER w/ 5 8"Ø x 6" WELDED HEADED STUDS @ 12"o.c. L3x3x1 4 STIFFENING RIBS @ 24"o.c. MAX 21" DP MIN x 8" W CONC BM w/ (2) #6 T&B & #6 @ 8"o.c. EA FACE w/ #3 TIES @ 8"o.c. W10x22 TYP @ 2 HUC 6 1 2 (2) 117 8" LVL LEDGER w/ 7 8"Ø THREADED RODS @ 16"o.c. STAGG EMBED 6" IN EPOXY - TYP (2) 117 8" LVL (2 ) 1 1 7 8" L V L (2 ) 1 1 7 8" L V L (2) 117 8" LVL (3) 117 8" LVL 6'-0" MIN - TYP 13'-4" TYP @ 2 (4) 2 x 4 TYP @ 2 (4) 2 x 4 ROOFING ASSEMBLY w/ WATERPROOFING & FLASHING PER ARCH 14 S5.02 TY P 91 2" TJI 210 @ 16"o.c. 7 S5.02 9 S5.02 8 S5.02 C1 5 x 3 3 . 9 - T . O . S T L = 1 0 0 ' - 1 5 8" 11 S5.02T.O. PLY = 99'-65 8" P.T. 2x8 @ 16"o.c. 1'-111 4" T.O. SLAB = 102'-6" AT HIGH PTS. (SLOPE TO DRAIN 1 4"/FT MIN PER ARCH) HUC 6 1 0 (2) 91 2" LVL LEDGER w/ 7 8"Ø THREADED RODS @ 16"o.c. STAGG EMBED 6" IN EPOXY - TYP @ DINING RM (3) 91 2" LVL (2) 117 8" LVL HDR T.O. PLY = 99'-111 4" 1 S5.02 TYP 2 S5.02 TY P BLOCKED DIAPH. w/ 3x NOMINAL BLK'G. 10d NAILS @ 4"o.c. EDGE & @ 12"o.c. FIELD - TYP MID ZONE (2) 117 8" LVL TYP @ SHOWER DEPRESSION 2x8 16"o.c. BLOCKED DIAPH. w/ 3x NOMINAL BLK'G. 10d NAILS @ 212'o.c. EDGE & @ 12"o.c. FIELD - TYP PERIM. ZONE 2x8 LEDGER RE: 1 5 / S 5 . 0 2 (4) 2 x 4 11'-8" W1 0 x 1 9 (2 ) 1 1 7 8" L V L HUC 4 1 2 11 7 8" T J I 5 6 0 @ 1 6 " o . c . - T Y P IT IS RECOMMENDED THAT ALL DAMAGED STRUCTURE BE RETROFIT WITH NEW FRAMING. NOTIFY S.E.O.R. OF EXISTING CONDITIONS FOR RETROFIT DESIGN PRIOR TO PROCEEDING WITH REPAIRS. ROOF & FLOOR FRAMING NOTES: 1. REFER TO SHEET S0.0 FOR GENERAL NOTES AND DETAILS, INCLUDING: - FLOOR & ROOF SHEATHING PER 1/S0.01. SEE CROSS HATCHED ZONES FOR BLOCKED DIAPHRAGMS. - TYPICAL WALL FRAMING PER 2/S0.01. - ATTACHMENT OF MULTI-PLY COLUMNS & BEAMS PER 3/S0.01. - ALL TYPICAL FRAMING CONNECTIONS PER SCHEDULE ON S0.01. 2. ALL COLUMNS SHOWN SHALL BE (2) 2x6, TYP - U.N.O. 3. ALL BEARING WALL HEADERS SHALL BE (2) 2x6, TYP - U.N.O. 4. ALL INTERIOR & EXTERIOR BEARING WALLS ARE 2x6 STUDS AT 16"o.c., TYP - U.N.O.. 5. ALL INTERIOR & EXTERIOR BEARING WALLS SHALL BE SHEATHED PER BRACED WALL PANEL NOTES ON S0.01, TYP - U.N.O. a. SPECIAL BRACE WALL PANELS PER SCHEDULE AND PLAN. b. ANY WALL OPENINGS TO BE MODIFIED SHALL BE APPROVED BY THE S.E.O.R. 6. ALL FRAMING MATERIAL EXPOSED TO WEATHER SHALL BE PRESERVATIVE PRESSURE TREATED PER S0.01 - U.N.O. 7. ALL DEAD LOAD SHALL BE APPLIED TO STRUCTURE PRIOR TO INSTALLING WINDOWS & DOORS. 8. SHOP DRAWINGS FOR LARGE AREAS OF GLAZING SHALL BE PROVIDED TO S.E.O.R. FOR REVIEW PRIOR TO FABRICATION TO COORDINATE CONNECTIONS & LOADING WITH MAIN BUILDING STRUCTURE. 9. ANCHOR ALL SILL PLATES TO TOP OF CONCRETE WITH 5 8" DIAMETER ANCHOR BOLTS WITH MINIMUM 7" EMBEDMENT AT 4'-0" MAXIMUM, 2 ANCHORS MINIMUM PER PLATE, 3" FROM EACH END, U.N.O.. REFER TO BWP SCHEDULE FOR ATYPICAL A.B.'S AND SPACINGS, REFER TO PLANS ABOVE FOR LOCATIONS. 10. ALL DIMENSIONS SHALL BE COORDINATED WITH ARCHITECTURAL DRAWINGS & FIELD VERIFIED BY CONTRACTOR. MAIN LEVEL FRAMING PLAN S1.02 REVISIONS: DATE: 2/27/17 PROJECT # : 17.001C DRAWN BY : SE CHECKED BY : SE 03/21/17 PERMIT STRUCTURAL DESIGN www.evolvestruct.com 1040 Main Street Carbondale, CO 81623 (970) 510-0773 54 1 R A C E S T R E E T R E S I D E N C E AS P E N , C O L O R A D O 09/19/17 CONST 05/11/18 HPC RESUBMIT MAIN LEVEL FRAMING PLAN SCALE: 1 4" = 1'-0" A N 8/17/18 nickt KITCHEN LIVING ROOM CLOSET POWDER ENTRY BEDROOM MASTER BATH DINING ROOM GARAGE P.E. HEADER w/ GLAZING SYSTEM DESIGN AS REQ'D - TYP HSS 5x5x5 16 - TYP @ GARAGE 2x 8 @ 1 2 " o . c . - T Y P @ G A R A G E U . N . O . W1 0 x 4 5 - C O P E D T O 5 " A T C A N T ' D E N D (3) 117 8" LVL 2x8 @ 24"o.c. (3) 117 8" LVL ALIGN NEW BM @ (E) BM LINE (E) EAVE AND RAFTER TO REMAIN - TYP P.E. ROOF GLAZING SYSTEM CUSTOM STL BRACKET TYP @ (E) LOG RAFTER TO NEW BM - V.I.F. (2) 71 4" LVL IN HUC - TYP IN (3) ROWS (E) LOG RAFTERS TO REMAIN SEE OTHER CABIN ROOF FRAMING FOR ADD'L TYP INFO NOT SHOWN W1 0 x 4 5 - C O P E D T O 5 " A T C A N T ' D E N D S 1 S5.03 TYP 4 S5.03 TY P 6 S5.03 TY P 5 S5.03 TY P TYP @ 9 HSS 5 x 5 x 5 16 (5) 2 x 6 HS S 5 x 5 x 5 16 - H I G H & L O W HS S 5 x 5 x 5 16 - H I G H & L O W (E) 6"Ø RAFTERS - TYP (E) 6"Ø RAFTERS - TYP (E) 6"Ø RAFTERS - TYP 2x 8 @ 2 4 " o . c . W8x58 @ 3'-0"o.c. MAX - BENT STL BM TYP @ 9 (E ) 2 x T & G D E C K I N G T O R E M A I N - T Y P OR R E P L A C E I N K I N D 2 S5.03 TYP 3 S5.03 TY P PACKOUT ALL BENTS PER 5/S5.02 w/ 2x6 LEDGER (1) SIDE MIN FOR DECKING NAILING - TYP W1 0 x 2 2 RE: 6/ S 5 . 0 2 (4) 2x 6 RE: 6/ S 5 . 0 2 (4) 2x 6 TYP @ 4 (4) 2 x 6 (E) HEADERS V.I.F. - TYP IT IS RECOMMENDED THAT ALL DAMAGED STRUCTURE BE RETROFIT WITH NEW FRAMING. NOTIFY S.E.O.R. OF EXISTING CONDITIONS FOR RETROFIT DESIGN PRIOR TO PROCEEDING WITH REPAIRS. HSS 5x5x5 16 - HIGH & LOW - TYP 9 S5.03 SHEATH WALL BELOW CLERESTORY WINDOWS PER BWP NOTES ON S0.01 - TYP TYP LB2 8 HS S 5 x 5 x 5 16 HSS 5x5x5 16 CONT - TYP STRUCT FASCIA 8 S5.03 TYP RE: 7/S5.03 TYP HSS 5x5x5 16 HSS 5x5x5 16 HSS 5x5x5 16 CONT - VALLEY BM P.E. ROOF GLAZING SYSTEM FP FLUE PENETRATIONS COORD w/ STL BENT LOCATION (E) PORCH FRAMING TO REMAIN - TYP T.O. STL 112'-63 4" 1' - 0 1 2" TY P T.O. STL 111'-03 8"T.O. STL 111'-03 8" T.O. STL 112'-63 4" T.O. STL 112'-01 4"T.O. STL 112'-01 4" ROOF & FLOOR FRAMING NOTES: 1. REFER TO SHEET S0.0 FOR GENERAL NOTES AND DETAILS, INCLUDING: - FLOOR & ROOF SHEATHING PER 1/S0.01. SEE CROSS HATCHED ZONES FOR BLOCKED DIAPHRAGMS. - TYPICAL WALL FRAMING PER 2/S0.01. - ATTACHMENT OF MULTI-PLY COLUMNS & BEAMS PER 3/S0.01. - ALL TYPICAL FRAMING CONNECTIONS PER SCHEDULE ON S0.01. 2. ALL COLUMNS SHOWN SHALL BE (2) 2x6, TYP - U.N.O. 3. ALL BEARING WALL HEADERS SHALL BE (2) 2x6, TYP - U.N.O. 4. ALL INTERIOR & EXTERIOR BEARING WALLS ARE 2x6 STUDS AT 16"o.c., TYP - U.N.O.. 5. ALL INTERIOR & EXTERIOR BEARING WALLS SHALL BE SHEATHED PER BRACED WALL PANEL NOTES ON S0.01, TYP - U.N.O. a. SPECIAL BRACE WALL PANELS PER SCHEDULE AND PLAN. b. ANY WALL OPENINGS TO BE MODIFIED SHALL BE APPROVED BY THE S.E.O.R. 6. ALL FRAMING MATERIAL EXPOSED TO WEATHER SHALL BE PRESERVATIVE PRESSURE TREATED PER S0.01 - U.N.O. 7. ALL DEAD LOAD SHALL BE APPLIED TO STRUCTURE PRIOR TO INSTALLING WINDOWS & DOORS. 8. SHOP DRAWINGS FOR LARGE AREAS OF GLAZING SHALL BE PROVIDED TO S.E.O.R. FOR REVIEW PRIOR TO FABRICATION TO COORDINATE CONNECTIONS & LOADING WITH MAIN BUILDING STRUCTURE. 9. ANCHOR ALL SILL PLATES TO TOP OF CONCRETE WITH 5 8" DIAMETER ANCHOR BOLTS WITH MINIMUM 7" EMBEDMENT AT 4'-0" MAXIMUM, 2 ANCHORS MINIMUM PER PLATE, 3" FROM EACH END, U.N.O.. REFER TO BWP SCHEDULE FOR ATYPICAL A.B.'S AND SPACINGS, REFER TO PLANS ABOVE FOR LOCATIONS. 10. ALL DIMENSIONS SHALL BE COORDINATED WITH ARCHITECTURAL DRAWINGS & FIELD VERIFIED BY CONTRACTOR. ROOF FRAMING PLAN S1.03 REVISIONS: DATE: 2/27/17 PROJECT # : 17.001C DRAWN BY : SE CHECKED BY : SE 03/21/17 PERMIT STRUCTURAL DESIGN www.evolvestruct.com 1040 Main Street Carbondale, CO 81623 (970) 510-0773 54 1 R A C E S T R E E T R E S I D E N C E AS P E N , C O L O R A D O 09/19/17 CONST 05/11/18 HPC RESUBMIT ROOF FRAMING PLAN SCALE: 1 4" = 1'-0" A N 8/17/18 nickt TYP FOOTING & WALL STEP1 S5.01 NOT TO SCALE TY P TYP 2' - 0 " M I N 2'-0" MIN 2'-6" MIN 2' - 0 " M A X 1'-0" - TYP #5 x 4'-0" DIAG, E.F. AT TOP OF WALL AND BOT OF WALL STEPS - TYP WALL FTG PER PLAN WALL FTG PER PLAN 57 BAR Ø (24" MIN) 57 B A R Ø (2 4 " M I N ) 57 BAR Ø (24" MIN) CORNER INTERSECTION & END OF WALL ALTERNATE CORNER 57 BAR Ø (24" MIN) CORNER BAR AT EA HORIZ BAR - TYP LAP HORIZ BARS EA SIDE OF CORNER - TYP (1) #5 VERT AT END OF WALL OR CORNER - TYP 12 D 'D ' R R R = 4D FOR #3 THRU #8 BARS R = 5D FOR #9 THRU #11 BARS R = 6D FOR # 14 AND #18 BARS 90° HOOK 180° HOOK R R 4D OFFSET 57 BAR Ø FOR CONC 64 BAR Ø FOR MASONRY TIED BARS MIN 1.5D OR 1" MAX 1/5 LAP LENGTH OR 6" LAP SPLICE 21 2" MIN 57 B A R Ø (2 4 " M I N ) TYP REINF AT CONC WALLS/GRADE BEAMS2 NOT TO SCALE TYP REINF DETAILS3 NOT TO SCALE PER PLAN T.O. FTG BASEMENT FDN DETAIL6 SCALE: 3 4" = 1'-0" BASEMENT WALL PER PLAN #5 x 3'-0" DOWELS @ EA VERT FND DRAIN & GRAVEL AS REQ'D PER GEOTECH PER PLAN T.O. SLAB 11 2" CLR DO NOT BACKFILL UNTIL FLOOR DIAPHRAGM IS FRAMED & S.O.G. IS IN PLACE INSULATION PER ARCH INT WALL FOOTING DETAIL4 3 4" = 1'-0" CONC FTG PER PLAN w/ REINF PER SCHED PER PLAN CONT 2x P.T. SILL PL w/ 5 8"Ø A.B. @ 48"o.c. S.O.G. PER PLAN - TYP INT 2x BEARING WALL PER PLAN 1 2" EXP JOINT MAT'L - TYP CONC CURB PER PLAN w/ #4 CONT TOP & #4 STD HOOK DOWELS @ 24"o.c. PER PLAN T.O. FTG PER PLAN T.O. SLAB PE R P L A N (2) #5 CONT AT TOP CONC FTG PER PLAN w/ REINF PER SCHED PE R PL A N PER PLAN FND DRAIN & GRAVEL AS REQ'D PER GEOTECH PER PLAN T.O. SLAB PER PLAN T.O. FTG WALL BEYOND PER PLAN & ARCH S.O.G. PER PLAN SLAB POUR OVER DETAIL5 3 4" = 1'-0" DRIVEWAY SLAB BY OTHERS, SLOPE PER GRADING PLAN #4 HOOKED DOWELS @ 24"o.c., CNTRD PER PLAN T.O. WALL CONC WALL PER PLAN S5.01 S5.01 S5.01 S5.01 S5.01 FTG PER PLAN SLAB PER PLAN 12" EXP JOINT MAT'L - TYP REVISIONS: DATE: 2/27/17 PROJECT # : 17.001C DRAWN BY : SE CHECKED BY : SE 03/21/17 PERMIT STRUCTURAL DESIGN www.evolvestruct.com 1040 Main Street Carbondale, CO 81623 (970) 510-0773 54 1 R A C E S T R E E T R E S I D E N C E AS P E N , C O L O R A D O S5.01 FOUNDATION DETAILS S 8/17/18 nickt (2) ROWS 1 2"Ø THRU BOLTS @ 48"o.c. - MIN (4) BOLTS PER PACKOUT MEMBER 2x OR LVL OUTER PLY SPACER BLKG FLUSH TO EDGE OF STEEL BEAR ON BOT FLANGE TYPICAL - U.N.O. PER PLAN ONE SIDE SHOWN RE: PLAN FOR ONE SIDE OR BOTH SIDES TO BE PACKED OUT 1" TYP 1" MA X U. N . O . 11 2" M I N 3" M A X 21 2" MI N 11 2" M I N 3" M A X TOP PL, 2x TYP U.N.O. SCALE: 3 4" = 1'-0" 5 TYP STEEL BEAM PACKOUT MULTIPLE TOP PL's SHALL BE ATTACHED TO BASE TOP PL w/ 10d COMMONS STGRD @ 6"o.c. RIPPED TOP PL TO MATCH BM FLANGE WIDTH, GLUE TO TOP FLANGE OF BM & ATTACH w/ 0.145"Ø P.A.F. STGRD @ 8"o.c. w/ 1 2" PEN INTO STL - TYP AT STEEL BEAM FLANGES < = 1 2". AT STEEL BEAM FLANGES > 12", GLUE TO TOP FLANGE OF BM & ATTACH w/ (2) ROWS OF 12"Ø THRU BOLTS @ 48"o.c. ADHESIVE SHALL BE PER PER GENERAL NOTES ON S0.0. DOUBLE 2x OR 3x MIN SOLID BLK'G PANEL @ 24"o.c. IN FIRST (3) BAYS - TYP JOIST PER PLAN INT FINISH PER ARCH 10" COINCRETE FOUNDATION WALL FLOOR SHTG & NAILING PER 1/S0.01 JOIST PER PLAN LEDGER PER PLAN - w/ WATERPROOFING BTWN CONC & WOOD BASEMENT WALL PER PLAN (E) 7"-9" LOGS FLOOR SHTG & NAILING PER 1/S0.01 JOIST PER PLAN INT FINISH PER ARCH BEAM PER PLAN FLOOR SHTG & NAILING PER 1/S0.01 JOIST PER PLAN INT FINISH PER ARCH BEARING WALL PER PLANS SCALE: 3 4" = 1'-0" 1 JOIST TO INT WALL DETAIL SCALE: 3 4" = 1'-0" 2 JOIST TO BEAM DETAIL SCALE: 3 4" = 1'-0" 3 JOIST BEARING AT FOUNDATION SCALE: 3 4" = 1'-0" 4 JOIST PARALLEL TO BASEMENT WALL SOLID BLK'G PANEL 3 16 2x NAILER AS REQ'D 1 2" MAX SOLID WOOD OR STEEL SHIM AS REQ'D END PL 1 4" 5" MIN PENETRATION INTO TOP PL/COL COL PER PLAN CNTRD BELOW BEAM (2) 5 8" Ø LAG SCREWS, ONE EA SIDE OF WEB STEEL BEAM PER PLAN TYP STEEL BM BEARING6 SCALE: 3 4" = 1'-0" DBL 2x TOP PL S5.02 S5.02 S5.02 S5.02 S5.02 S5.02 (E) 7"-9" LOGS NAILS @ 21 2"o.c. TO BLKG 7" MIN P.T. 2x6 SILL PLATE MIN PL 1 4 x 12 x 1'-0" @ 48"o.c. MAX w/ (3) 5 8"Ø THREADED RODS @ 4"o.c. EMBED 4" IN EPOXY TO CONC & (5) 1 4"Ø x 6" SDS SCREWS @ 2"o.c. TO SILL LOG 2" CLR (2) #5 CONT AT TOP #4 x 36" DOWEL @ 24"o.c. TYP 4'-0" MIN REVISIONS: DATE: 2/27/17 PROJECT # : 17.001C DRAWN BY : SE CHECKED BY : SE 03/21/17 PERMIT STRUCTURAL DESIGN www.evolvestruct.com 1040 Main Street Carbondale, CO 81623 (970) 510-0773 54 1 R A C E S T R E E T R E S I D E N C E AS P E N , C O L O R A D O FRAMING DETAILS S5.02 S 8/17/18 nickt 1'-63 4" VA R I E S 6'-6" 4'-03 4" 2'-4" 93 8" 1'-0" TYP 2'-4" ROOF SHTG & NAILING PER 1/S0.01 2x NAILER & PACKOUTS PER 5/S5.02 BM PER PLAN BM PER PLAN, TYP HANGER PER PLAN, TYP JOISTS PER PLAN GLAZING PER ARCH 5" BM PER PLAN - COPE EAVE DEPTH MAX AS NOTED COLUMN PER PLAN INT FINISH PER ARCHEXT FINISH PER ARCH ROOF SHTG & NAILING PER 1/S0.01 2x NAILER & PACKOUTS PER 5/S5.02 111 2" ROOF ASSEMBLY PER ARCH - TYP (E) 7"-9" LOGS (E) 7"-9" LOGS - TYP BM PER PLAN BM PER PLAN ROOF DECKING PER PLAN BM PER PLAN (E) LOG RAFTERS TO REMAIN (E) LOG RAFTERS TO REMAIN SCALE: 3 4" = 1'-0" 6 GARAGE ROOF PERIMETER DETAIL SCALE: 3 4" = 1'-0" 5 GARAGE ROOF PERIMETER DETAIL SCALE: 3 4" = 1'-0" 1 ROOF PERIMETER DETAIL SCALE: 3 4" = 1'-0" 2 ROOF RIDGE DETAIL SCALE: 3 4" = 1'-0" 3 ROOF PITCH CHANGE DETAIL SCALE: 3 4" = 1'-0" 4 ROOF PERIMETER DETAIL BM PER PLAN w/ 2x NAILER T&B FULL PEN TYP @ ALL BENTS TYP 1 4 BM PER PLAN BEYOND FULL PEN TYP @ ALL BENTS S5.03 S5.03 S5.03 S5.03 S5.03 S5.03 (4) 1 4"Ø x 8" SDS SCREWS TYP REVISIONS: DATE: 2/27/17 PROJECT # : 17.001C DRAWN BY : SE CHECKED BY : SE 03/21/17 PERMIT STRUCTURAL DESIGN www.evolvestruct.com 1040 Main Street Carbondale, CO 81623 (970) 510-0773 54 1 R A C E S T R E E T R E S I D E N C E AS P E N , C O L O R A D O FRAMING DETAILS S5.03 S 8/17/18 nickt RA C E A L L E Y C A B I N 54 1 R A C E S T AS P E N , C O 8 1 6 1 1 8/17/18 nickt LA LB LC LE LG 001 002 003 004 005 006 007 008 009 010 011 012 014 015 013 009 TO OSA INTAKE 1000 CFM ASSUMED 14x12 OR EQ. RA C E A L L E Y C A B I N 54 1 R A C E S T AS P E N , C O 8 1 6 1 1 12 x 1 0 12 x 1 0 20x1012x6 6" Ø 6" Ø 6" Ø 8x6 6"Ø TYP. 8 6"Ø TYP. 8 16 x 1 4 16x14 4" 4" 4" 4" 8/17/18 nickt RA C E A L L E Y C A B I N 54 1 R A C E S T AS P E N , C O 8 1 6 1 1 GA GV GU GT GL GK GJ GI GH GGGF GE GD GC GB GM 101 102 103 104 105 106 107 ABOVE GO ABOVE GP ABOVE GQ ABOVE GN GR ABOVE GS ABOVE 108 109 110 111 112 SAFETY GLAZING SAFETY GLAZING SAFETY GLAZING SAFETY GLAZING SAFETY GLAZING SAFETY GLAZING OSA UP TO LOUVER IN SIDEWALL ABOVE ROOF LINE OF DINING ROOM UNIT LOCATED IN ATTIC IN PANBRANCH DROPS TO CEILING OF LOWER LEVEL TO REACH THE FLOOR REGISTERS SERVING MASTER/WIC 14 x 1 2 7"Ø TYP. 3 7"Ø TYP. 3 10x10 5"Ø 8x 8 6"Ø 6" Ø 7" Ø 20x10 20 x 1 0 8x8 5" 5" 7" 7" 7" 7" 10x10 Louver 10x10 Louver 8/17/18 nickt