HomeMy WebLinkAboutFile Documents.728 E Hopkins Ave.0186.2019 (34).ARBKCIVIL ENGINEER: - CONTACT: - - COL. C.O. CEILING HEIGHT A.F.F.+13'-11" PROJECT ADDRESS: PARCEL ID: FIRE SPRINKLER SYSTEM INSTALLED: APPLICABLE CODES: ·2015 IBC (International Building Code) Chapters 1-10 ·2015 IBC appendixes: ·Manufactured homes, F: Radon, J: Existing Buildings & Structures, H:Patio Covers, K: Sound Transmission. ·2015 IPC (International Plumbing Code) ·2015 IMC (International Mechanical Code) ·2015 IFGC (International Fuel Gas Code) ·2015 IECC (International Energy Conservation Code) - Prescriptive Path ·2015 IFC (International Fire Code) ·2017 NEC (National Electrical Code) 728 E. HOPKINS AVE. 273707361001 YES MU 3,890.62 sq ft EXISTING, 3,890.62 sq ft PROPOSED (NO CHANGE) Residential Front - 10', Side 5' and Rear - 5' ZONING: F.A.R. PERMITTED USE: SETBACKS: Tread Terrazzo Thick Tempered TEL. T.C. T.B. T. THK. T.M.E. T.O.C. T.&G. TER. TEMP. To Match Existing Top of Concrete Towel Bar Top of Curb Telephone Tongue & Groove Typical Varies UnfinishedUNF. V.C.T. VAR. U.O.N. UNEXC. U.B.C. T.O. PLY T.O.W. TYP. Veneer Vertical Vestibule Volume Wood West With V.I.F. W.C. WD. W.H. W. W/ V.G.D.F. VOL. VERT. VEST. VEN. Wall Covering Water Heater Vertical Grain Douglas Fir Verify in Field Vinyl Composition Tile Top of Plywood Top of Wall Uniform Building Code Unexcavated Unless Otherwise Noted Top of PlateT.O.P. Wainscot Weight W.P. WW. WR. WT. W.S.P. W.P.M. WSCT. Welded Wire Work Point or Waterproofing Waterproof Membrane Wet Standpipe Water Resistant WithoutW/O REQ. RESIL. REINF. REG. REV. RWD. REMOV. R.O. RM. RET. Rough Opening Redwood Required Removable Room Resilient Retaining Reinforced Register Mounted Mullion Nominal North Number New Not to Scale Miscellaneous Not in Contract S.C.D. S.D. S. S.A.F.F SEP. SHT. S.H. SECT. S.E.D. SCHED. Separation Sprinkler Head Sheet See Civil Drawings Soap Dispenser/Dish See Electrical Drawings Storm Drain, Schedule Section Self-Adhesive Flexible Flashing South S.G.D. S.L.D. SHTG. S.C.D. SL. SIM. S.P.D. SPEC. S.M.D. S.S. SQ. S.LT.D. Stainless Steel Square See Lighting Drawings See Garage Drawings See Plumbing Drawings See Civil Drawings Sheathing Sliding Similar Opposite Opening On Center Overall Plaster Plywood Perimeter Plate Plastic Laminate Outside Diameter (Dim.) Point Paint Quarry Tile Partition Painted Paper Towel Receptacle Per Square Inch Pressure Treated Post Tensioned Paper Towel Dispenser Panel MUL. MISC. MTD. NOM. N.T.S. N.I.C. N. (N) Hardware Hardwood Hanger Height Horizontal Handrail Hour Hot Water Heater Hollow Metal HGT. HDW. HDWD. HGR. H.W.H. HORIZ. HR. H.R. H.M. Floor Drain Fire Extinguisher Cabinet Flat Bar Fixture Floor Srew Finish Flat Head Wood Screw Flat Head Machine OPP. O.A. O.C. O.D. PLAS. PL. Insulation Interior Inch Kitchen Joist Joint Janitor Junction Box Intermediate P.S.I. PNT. PT. P.T. P.T.R. P.T.D. PTN. Q.T. PTD. Laminate Lavatory Pound Linear Light Maintain Material Maximum Machine PNL. INTER. IN. INSUL. INT. KIT. JST. JB JT. JAN. Fluorescent Face of Finish Face of Plywood Face of Stud Footing Furring Future Frame Foot or Feet Fireproof Face of Concrete LB. LIN. LT. LAM. LAV. MAINT. MAT. MAX. MACH. General Gauge Gas Outlet Galvanized Ground Grade Glass Interrupt Ground Fault Galvanized Sheet Garbage Disposal Flashing Inside DiameterI.D. ABBREVIATIONS P.LAM. PLYWD. PERIM. OPNG. NO. or # STOR. STRL. STD. STL. S.V. SYS. SYM. S.W. System Steel Structural Sheet Vinyl Shear Wall Symmetrical Storage StandardReturn Air Recessed Radius Riser Reference Reflected Refrigerator REC. RAD. R.A. R. REFR. REFL. REF. Overlay Mechanical Membrane Minimum Metal Machine Bolt Medicine Cabinet Medium Density Manufacturer M.D.O. MEMB. MECH. M.B. M.C. MIN. MTL. MFR. Gypsum Handicapped Hose Bibb Hollow Core or Header Head Hardboard Metal S.S.D. See Structural Drawing Specification or Special See Landscape Drawings See Mechanical Drawings Revision/Revised/Reversed F.E. F.B. F.D. FIXT. FLR. F.H.W.S. FIN. F.H.M.S. CONSTR. CONN. COND. CONC. CTR. C.W. C.T. CONTR. CLOS. CONT. Center Cold Water Contractor Closet Ceramic Tile Condition Connection Construction Continuous Concrete F.O. Ply F.O.S. FLUOR. F.O.C. F.O.F. FURR. FUT. FTG. FR. FT. F.P.R.F. GALV. G.D. GEN. G. GA. GND. G.S.M. GR. GL. G.F.I. DIA. DIM. DBL. DET. D.F. DWG. DWR. D.W. DN. DR. DISP. E.J. EA. (E) E.I.F.S. E.O.S. ENCL. E.P.B. ELEC. EMER. EL. Dishwasher Edge of Slab Electrical Panel Board Enclosure Exterior Insulation & Elevation Electrical Emergency Existing Finish System Expansion Joint Each Drawing Drawer Drinking Fountain Dispenser Down Door Double Diameter Dimension Detail FLASH. At@ & < A.C. # 0 ACOUS. ALUM. ALT. ADJ. AGGR. ADJAC. BITUM. BD. ARCH. ASPH. APPROX. BM. B.O. BOT BLKG. BLK. C.B. CEM. CER. B.P. BTWN. BLDG. A.D. Catch Basin Cement Ceramic Beam Bottom of Building Paper Between Bottom Building Blocking Bituminous Board Block Diameter or Round Air Conditioning or Asphaltic Concrete Aluminum Approximate Architectural Asphalt Alternate Acoustical Area Drain Adjustable Aggregate Adjacent Pound or Number Angle And H.B. H.C. GYP. HDR. HDBD. HD. EXP. EXT. EXIST. EQUIP. F.A.U. F.A. Forced Air Unit Fire Alarm Equipment Existing Expansion Exterior CLKG. C.M.U. CLR. CLG. CNTR. Column Concrete Masonry Caulking Clean-Out Counter Unit Clear Ceiling C.J. Control Joint EqualEQ. PROJECT DIRECTORYVICINITY PLAN CONTACT: Ryan Doremus STRUCTURAL ENGINEER: LANDSCAPE DESIGN: OWNER/CLIENT: ARCHITECT: Aspen, CO 81611 Thunderbowl Architects 300 Spring St. Suite 201 Email: ryan@thunderbowlarchitects.com RMJ Hopkins LLC SHEET NUMBER INTERIOR ELEVATION NUMBERS SYMBOLS 3 A6.1 1 A4.3 DOOR SYMBOL14 1A A 3 A6.1 DETAIL NUMBER SHEET NUMBER WINDOW SYMBOL PARTITION TYPE SHEET NUMBER BUILDING SECTION NUMBER SHEET NUMBER ENLARGED DETAIL NUMBER HOSE BIBB REVISION COLOR FINISH MATERIAL HB JB XX X 1 (N)/(E) CONSTRUCTION JUNCTION BOX ASPEN, COLORADO 728 E. HOPKINS AVE. GENERAL NOTES PROJECT STATISTICS TYPE: OCCUPANCY: OVERALL PROJECT HEIGHT AND AREA: PROJECT SUMMARY: Type V - Non-rated Type R-3 Maximum Height N/A - Area N/A INTERIOR REMODEL OF EXISTING BATHROOMS AND UPDATING KITCHEN CABINETRY AND PLUMBING FIXTURES. - - CONTACT: - CONTRACTOR A5.2 1 2 3 4 FOR ALL DRAWINGS EXCEPT DETAILS DIMENSIONING KEY TICK LEADER DENOTES DIMENSION TO FRAMING DOT LEADER DENOTES DIMENSION TO GRIDLINE/< 2'-2"3'-6" ARROW LEADER DENOTES DIMENSION TO FINISH 3'-5" CHANGE ORDER #1 07/10/2019 The work included under this contract consists of all labor, materials, transportation, tools and equipment necessary for the construction of the project leaving all work ready for use. The construction documents are the property of Thunderbowl Architects Inc and its Consultants and are to be used as instruments of service for construction of this project only. Use for any other purpose, without authorization, is not allowed. The plans indicate the general extent of new construction necessary for the work, but are not intended to be all-inclusive. All demolition and all new work necessary to allow for a finished job in accordance with the intention of the drawing is included regardless of whether shown on the drawings or mentioned in the notes. Any errors, omissions or conflicts found in the various parts of the construction documents shall be brought to the attention of the Architect and the Owner for clarification before proceeding with the work. The General Contractor shall maintain a current and complete set of the construction documents on the job site during all phases of construction for use of all the trades and shall provide all the subcontractors with current and complete construction documents as required including specifications and architectural supplementary instructions. The General Contractor shall verify and assume responsibility for all dimensions and site conditions. The General Contractor shall inspect the existing premises and take note of existing conditions prior to submitting prices. No claim shall be allowed for difficulties encountered which could have reasonably been inferred from such an examination. Written dimensions take precedence. Do not scale drawings. See SYMBOLS area of this sheet for dimension standards. All dimensions noted "verify" and "V.I.F." are to be checked by Contractor prior to construction. Immediately report any variances to the Architect for resolution, then coordinate resolution w/ all work of all trades. Coordinate all work with existing conditions, including but not limited to: irrigation pipes, electrical conduit, water lines, gas lines, drainage lines, etc. Notify Architect immediately of any conflicts. Provide adequate temporary support as necessary to assure the structural value or integrity of the building. Protect all existing building and site conditions to remain, including walls, cabinets, finishes, trees and shrubs, paving, etc. Details shown are typical. Similar details apply in similar conditions. Verify all architectural details with structural, civil, landscape and design/build drawings before ordering or installation of any work. All changes in floor materials occur at centerline of door or framed opening unless otherwise indicated on the drawings. Install all fixtures, equipment and materials per manufacturer's recommendations. Verify clearances for flues, vents, chases, soffits, fixtures, etc. before any construction, ordering of, or installation of any items of work. Sealant, caulking and flashing, etc. locations shown on drawings are not intended to be inclusive. Follow manufacturer's installation recommendations and standard industry and building practices. The General Contractor shall remove all rubbish and waste materials of all subcontractors and trades on a regular basis, and shall exercise a strict control over job cleaning to prevent any direct debris or dust from affecting, in any way, finished areas in or outside job site. Contractor shall leave premises and all affected areas clean and orderly, ready for occupancy. This includes cleaning of all glass (inside and outside) and frames, both new and existing. Any survey monuments within the area of construction shall be preserved or reset by a registered civil engineer or a licensed land surveyor. Verify all finish materials with the Architect and the Owner prior to installation. On site mock-ups of building assemblies, finish assemblies, paint and/or stain samples, etc. may be required for approval. Contractor to coordinate utilities shown on architectural drawings with electrical, plumbing, mechanical, and any other consultant drawings. Contractor to coordinate all the trades. Structural observation shall be required by the Engineer for structural conformance to the approved plans. It is the General Contractors responsibility to obtain inspections and special inspections as necessary. All construction to provide a waterproof, weather tight building. Contractor should flash and caulk as necessary to achieve this requirement. S. South - CONTACT: - - Rudd Construction CONTACT: Scott Duryea 132 Park Ave. - 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. SHEET INDEX NOT INCLUDED IN THIS SET INCLUDED IN THIS SET DELETED FROM SET Basalt, CO 81621 MECHANICAL DESIGN: - - CONTACT: -Tel: (XXX) XXX-XXXX Email: Tel: (XXX) XXX-XXXX Email: Tel: (XXX) XXX-XXXX Email: Tel: (XXX) XXX-XXXX Email: Tel: (970) 927-9119 Email: scott@ruddconstruction.com - Tel: (970) 274-1421 Boca Raton, FL 33431 2200 Butts Rd #220 - SITE 728 E. HOPKINS AVE. ASPEN, COLORADO DATES ISSUED PE R M I T S E T | 02 / 1 3 / 2 0 1 9 SHEET TITLESHEET NUMBER CH A N G E O R D E R # 1 | 07 / 1 0 / 2 0 1 9 G-000 COVER SHEET G-001 VIEW FROM E. HOPKINS AVE Z-100 FLOOR AREA CALCULATIONS A-100X EXISTING-DEMO LOWER LEVEL FLOOR PLAN A-101X EXISTING-DEMO LOWER LEVEL RCP A-110X EXISTING-DEMO MAIN LEVEL FLOOR PLAN A-111X EXISTING-DEMO MAIN LEVEL RCP A-120X EXISTING-DEMO UPPER LEVEL FLOOR PLAN A-121X PROPOSED UPPER LEVEL RCP A-100 PROPOSED LOWER LEVEL FLOOR PLAN A-101 PROPOSED LOWER LEVEL RCP A-110 PROPOSED MAIN LEVEL FLOOR PLAN A-111 PROPOSED MAIN LEVEL RCP A-120 PROPOSED UPPER LEVEL FLOOR PLAN A-121 PROPOSED UPPER LEVEL RCP A-201 EXTERIOR ELEVATIONS A-202 EXTERIOR ELEVATIONS A-501 ASSEMBLY DETAILS PROJECT SCALE N/A 18011.00 G-000 COVER SHEET CO P Y R I G H T 2 0 1 9 T H U N D E R B O W L A R C H I T E C T S AS P E N , C O L O R A D O PA R C E L I D # 27 3 7 0 7 3 6 1 0 0 1 72 8 E . H O P K I N S A V E . C TH U N D E R B O W L AR C H I T E C T S THUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 02/13/2019 PERMIT SET 07/10/2019 CHANGE ORDER #1 1 1 1 1 1 1 10/09/2019 PROJECT SCALE N/A 18011.00 G-001 VIEW FROM E. HOPKINS AVE CO P Y R I G H T 2 0 1 9 T H U N D E R B O W L A R C H I T E C T S AS P E N , C O L O R A D O PA R C E L I D # 27 3 7 0 7 3 6 1 0 0 1 72 8 E . H O P K I N S A V E . C TH U N D E R B O W L AR C H I T E C T S THUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 02/13/2019 PERMIT SET 07/10/2019 CHANGE ORDER #1 1 PROPOSED DECK VIEW FROM STREET2 G-001 EXISTING DECK VIEW FROM STREET1 G-001 NEW DECK WALL. WOOD SHAKE FINISH TO MATCH EXISTING. NEW DOOR. COLOR TO MATCH EXISTING. NEW WINDOW STYLE. COLOR TO MATCH EXISTING. NEW INFILL AREA. FINISH & COLOR TO MATCH EXISTING. 1 10/09/2019 1 2 3 4 5 A B C LOWER LEVEL FLOOR AREA 1795.89 SQ. FT. DW TR A S H 1 2 3 4 5 A B C UPPER LEVEL FLOOR AREA 937.85 SQ. FT. OPEN TO BELOW 62.94 SQ. FT. DECK FLOOR AREA 227.19 SQ. FT. 1 2 3 4 5 A B C MAIN LEVEL FLOOR AREA 1099.14 SQ. FT. GARAGE FLOOR AREA 365.48 SQ. FT. OPEN TO BELOW 8.43 SQ. FT. FRONT PORCH EXEMPT: 226.45 SQ. FT. 26.575.020.D.5 1 2 3 4 5 A B C MAIN LEVEL FLOOR AREA 1099.14 SQ. FT. GARAGE FLOOR AREA 365.48 SQ. FT. FRONT PORCH EXEMPT: 226.45 SQ. FT. 26.575.020.D.5 OPEN TO BELOW 8.43 SQ. FT. 1 2 3 4 5 A B C UPPER LEVEL FLOOR AREA 937.85 SQ. FT. DECK FLOOR AREA 146.76 SQ. FT. OPEN TO BELOW 62.94 SQ. FT. 1 2 3 4 5 A B C LOWER LEVEL FLOOR AREA 1795.89 SQ. FT. PROPOSED UPPER LEVEL FLOOR AREA PLAN 1/8" = 1'-0" 3 Z-100 PROPOSED MAIN LEVEL FLOOR AREA PLAN 1/8" = 1'-0" 2 Z-100 PROPOSED LOWER LEVEL FLOOR AREA PLAN 1/8" = 1'-0" 1 Z-100 PROJECT SCALE 1/8" = 1'-0" 18011.00 Z-100 FLOOR AREA CALCULATIONS GARAGE AREA FLOOR AREA FLOOR AREA LEGEND DECK AREA CO P Y R I G H T 2 0 1 9 T H U N D E R B O W L A R C H I T E C T S AS P E N , C O L O R A D O PA R C E L I D # 27 3 7 0 7 3 6 1 0 0 1 72 8 E . H O P K I N S A V E . C TH U N D E R B O W L AR C H I T E C T S THUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 02/13/2019 PERMIT SET 07/10/2019 CHANGE ORDER #1 1 EXISTING UPPER LEVEL FLOOR AREA PLAN 1/8" = 1'-0" 6 Z-100 EXISTING MAIN LEVEL FLOOR AREA PLAN 1/8" = 1'-0" 5 Z-100 EXISTING LOWER LEVEL FLOOR AREA PLAN 1/8" = 1'-0" 4 Z-100 EXISTING FLOOR AREA CALCULATIONS LOWER LEVEL 1,795.89 sq. ft. MAIN LEVEL (EXCLUDING GARAGE)1,099.14 sq. ft. UPPER LEVEL 937.385 sq. ft. GARAGE 57.74 sq. ft. UPPER LEVEL FRONT DECK 146.76 sq. ft. 365.48 - 250 = 114.48 sq.ft. 114.48 / 2 = 57.74 sq.ft. 3,890.62 sq. ft. 146.76 sq. ft. 583.59 sq. ft. ALLOWABLE DECK SQ. FT. TOTAL COUNTABLE FLOOR AREA GROSS DECK AREA 0 sq. ft. TOTAL COUNTABLE DECK FLOOR AREA 3,890.62 (TOTAL FLOOR AREA) X 15% 3,890.62 sq. ft. TOTAL F.A.R. PROPOSED FLOOR AREA CALCULATIONS LOWER LEVEL 1,795.89 sq. ft. MAIN LEVEL (EXCLUDING GARAGE)1,099.14 sq. ft. UPPER LEVEL 937.385 sq. ft. GARAGE 57.74 sq. ft. UPPER LEVEL FRONT DECK 289.01 sq. ft. 365.48 - 250 = 114.48 sq.ft. 114.48 / 2 = 57.74 sq.ft. 3,890.62 sq. ft. 227.19 sq. ft. 583.59 sq. ft. ALLOWABLE DECK SQ. FT. TOTAL COUNTABLE FLOOR AREA GROSS DECK AREA 0 sq. ft. TOTAL COUNTABLE DECK FLOOR AREA 3,890.62 (TOTAL FLOOR AREA) X 15% 3,890.62 sq. ft. TOTAL F.A.R. 1 1 1 1 10/09/2019 1 2 3 4 5 A B C 74'-1 15/16" 18'-11 5/8"41'-5 3/4"6'-1 3/4"7'-6 13/16" 19 ' - 2 7 / 1 6 " 24 ' - 0 " 4' - 9 1 / 2 " 1 2 3 14 15 16 4 F.P. TO BE ELIMINATED F.P. TO BE ELIMINATED F.P. TO BE ELIMINATED WALLS TO BE REMOVED LOUNGE 112 CARPET MECHANICAL 111 CONCRETE LAUNDRY 110 TILE CLOSET 2 106 CARPET STORAGE 108 BEDROOM 2 105 CARPET BEDROOM 1 104 CARPET CLOSET 1 103 CARPET BATH 1 102 TILE BATH 2 107 TILE HALLWAY 101 CARPET STAIR 100 CARPET DN3R @ 7" 12" T TYP UP 14 R @ 7 " 10 - 1 / 2 " T T Y P CP T TI L E CP T TI L E TILECONC TILECPT CPTTILE CP T TI L E WINE ROOM 114 TILE STORAGE 113 CONCRETE 4 17 2 3 5 12 14 15 16 17 2 3 7 8 14 15 16 17 2 3 10 11 12 13 14 15 16 17 2 3 7 14 15 16 17 2 3 7 14 15 16 17 2 3 14 15 16 17 2 3 10 11 12 14 15 16 17 2 3 14 15 16 17 2 3 14 15 16 2 3 9 14 15 16 2 3 14 15 16 18 19 612314 15 16 17 1 2 3 9 15 16 17 CPTCONC CPTTILE CPTTILE CP T TI L E CPT TILE 110A 111A 105A 102A 103A 108A 107A 107B 106A FAMILY ROOM 109 CARPET 104A 107C 109A 113A 114A T.O. LOWER LEVEL F.F. +89'-10" EXISTING PARTITION WALLS BETWEEN UNITS ASSUMED TO BE RATED NOT TO BE DISTURBED N 0 2 4 8 Scale: 1/4" = 1'-0" EXISTING-DEMO LOWER LEVEL FLOOR PLAN 1/4" = 1'-0" 1 A-100X PROJECT SCALE 1/4" = 1'-0" 18011.00 A-100X EXISTING-DEMO LOWER LEVEL FLOOR PLAN CO P Y R I G H T 2 0 1 9 T H U N D E R B O W L A R C H I T E C T S AS P E N , C O L O R A D O PA R C E L I D # 27 3 7 0 7 3 6 1 0 0 1 72 8 E . H O P K I N S A V E . C TH U N D E R B O W L AR C H I T E C T S THUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 02/13/2019 PERMIT SET 07/10/2019 CHANGE ORDER #1 1 DEMOLITION NOTES 1.FURNISH EQUIPMENT AND PERFORM LABOR REQUIRED TO EXECUTE THE CONTRACT DOCUMENTS. 2.PROTECT EXISTING WORK TO REMAIN INCLUDING DUST CONTROL. 3.THE DRAWINGS DO NOT NECESSARILY INDICATE THE FULL EXTENT OF THE WORK TO BE PERFORMED. INSPECT THE EXISTING CONSTRUCTION CAREFULLY TO DETERMINE THE FULL EXTENT OF WORK TO BE PERFORMED AND THE CHALLENGES INVOLVED. 4.DO NOT ALLOWED DEMOLISHED DEBRIS TO ACCUMULATE ON SITE BEYOND A REASONABLE AMOUNT. MAINTAIN PROGRESSIVE DISPOSE OF DEBRIS IN A LEGAL MANNER. 5.REMOVAL OF ALL HAZARDOUS MATERIALS IS THE RESPONSIBILITY OF THE OWNER. SHOULD THE CONTRACTOR ENCOUNTER ANY HAZARDOUS MATERIALS WHILE EXECUTING DEMOLITION, THEY SHOULD CONTACT THE OWNER IMMEDIATELY. 6.VERIFY ALL SALVAGING REQUIREMENTS WITH THE OWNER PRIOR TO DEMOLITION. 7.NOTIFY OWNER 48 HOURS PRIOR TO ANY UTILITY SERVICE DISRUPTION. 8.COORDINATE EXTENT OF ALL STRUCTURAL DEMOLITION WITH THE STRUCTURAL DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR DESIGN AND IMPLEMENTATION OF TEMPORARY SHORING AND BRACING AS REQUIRED. 9.VERIFY EXTENT OF WALL AND ROOF REMOVAL WITH STRUCTURAL ENGINEER. 10.PRIOR TO COMMENCEMENT OF DEMOLITION, EXTENT OF STRUCTURE AND/OR FINISH TO BE REMOVED MUST BE VERIFIED WITH BOTH THE OWNER AND ARCHITECT. 11.PROVIDE NECESSARY EROSION CONTROL PER LANDSCAPING OR CIVIL DRAWINGS. LEGEND SEE A0.00 FOR SYMBOLS NOT SHOWN HERE. (E) CONST. TO BE REMOVED OR NEW MASONRY WALL PARTITION WALL BETWEEN UNITS NEW CONSTRUCTION EXISTING CONSTRUCTION AREA OF WORK KEY NOTES LEGEND: LOWER LEVEL EXISTING ELIMINATE WALLS1 2 3 4 5 REPLACE FLOORING RELOCATE MECHANICAL EQUIPMENT RECONFIGURE LAUNDRY ROOM REMOVE DUMBWAITER - CHASE T.B.D.6 ELIMINATE FIREPLACE7 ADDITIONAL BEDROOM TO BE ADDED8 BUILT-IN / STORAGE AREA TO BE ADDED9 BATHROOM TO BE UPDATED10 FIXTURES TO BE REPLACED 11 DOUBLE VANITY TO BE ADDED 12 BATHROOM FINISHES TO BE UPDATED UPDATE LIGHTING 13 UPDATE WALL FINISHES UPDATE SWITCHES / OUTLETS/ SWITCH PLATES 14 15 UPDATE BASE AND TRIM16 REPLACE DOORS/ UPDATE DOOR HARDWARE17 UPDATE STAIR TREADS18 UPDATE STAIR HANDRAIL19 1 1 1 10/09/2019 LOUNGE 112 WINE ROOM 114 STORAGE 113 MECHANICAL 111 LAUNDRY 110 FAMILY ROOM 109 CLOSET 2 106 STORAGE 108 BEDROOM 2 105 BEDROOM 1 104 CLOSET 1 103 BATH 1 102 BATH 2 107 HALLWAY 101 1 2 3 4 5 A B C 74'-1 15/16" 18'-11 5/8"41'-5 3/4"6'-1 3/4"7'-6 13/16" 19 ' - 2 7 / 1 6 " 24 ' - 0 " 4' - 9 1 / 2 " STAIR 100 7'-7" GB 7'-7" GB 7'-7" GB 7'-11" GB 7'-11" GB 8'-10" GB 8'-10" GB 8'-10" GB 8'-10" GB 8'-10" GB 8'-10" GB 8'-10" GB 8'-10" GB F F C.O. S.D. C.O. S.D. COVE LIGHT T.A. T.A. F C.O. S.D. C.O. S.D. N 0 2 4 8 Scale: 1/4" = 1'-0" EXISTING-DEMO LOWER LEVEL RCP 1/4" = 1'-0" 1 A-101X PROJECT SCALE 1/4" = 1'-0" 18011.00 A-101X EXISTING-DEMO LOWER LEVEL RCP CO P Y R I G H T 2 0 1 9 T H U N D E R B O W L A R C H I T E C T S AS P E N , C O L O R A D O PA R C E L I D # 27 3 7 0 7 3 6 1 0 0 1 72 8 E . H O P K I N S A V E . C TH U N D E R B O W L AR C H I T E C T S THUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 02/13/2019 PERMIT SET 07/10/2019 CHANGE ORDER #1 1 LEGEND SEE COVER SHEET FOR SYMBOLS NOT SHOWN HERE. REFLECTED CEILING PLAN GENERAL NOTES SP ALL DIMENSIONS ARE TO FACE OF FIN., CENTER OF FIXTURE/REGISTER UNLESS NOTED OTHERWISE. VERIFY IN FIELD ALL EXISTING DIMENSIONS. LIGHT FIXTURES SHOWN ON THIS PLAN ARE FOR REFERENCE ONLY. SEE LIGHTING DRAWINGS FOR TYPE, LOCATION, AND CIRCUITING. ALSO SEE INTERIOR ELEVATIONS FOR LOCATION OF SCONCES, TYP. PAINT ALL RECESSED CAN TRIMS/MECHANICAL GRILLES THE COLOR OF THE CEILING IN WHICH THEY APPEAR. COORDINATE FIXTURE LAYOUT WITH ALL EXISTING AND PROPOSED STRUCTURE. ALL EXISTING LIGHTING TO BE REPLACED 1. 2. 3. 4. 5. 6. 7. +8'-0" SEE LIGHTING DRAWINGS FOR ALL LIGHT SYMBOLS AIR OUTLET, VERIFY WITH MECH. SUB. AIR INTAKE, VERIFY WITH MECH. SUB. CEILING MOUNTED SMOKE DETECTOR SPEAKER, VERIFY AV REQUIREMENTS WITH OWNER CEILING/SOFFIT HEIGHT SYMBOL C.O. S.D. F EXHAUST FAN (110 V) FLUORESCENT LIGHT FIXTURE RECESSED DOWNLIGHT DIRECTIONAL RECESSED DOWNLIGHT SURFACE MOUNTED DOWNLIGHT EXPOSED SPRINKLER HEAD RECESSED SPRINKLER HEAD WALL MOUNTED FIXTURE LARGE PENDANT LIGHT FIXTURE 1 1 10/09/2019 1 2 3 4 5 A B C 74'-1 15/16" 18'-11 5/8"41'-5 3/4"6'-1 3/4"7'-6 13/16" 19 ' - 2 7 / 1 6 " 24 ' - 0 " 4' - 9 1 / 2 " DN4R @ 7" 9" T TYP TILE TILE GARAGE 211 CONCRETE GUEST CLOSET 208 WOOD GUEST MASTER 207 WOOD GUEST BATH 209 TILE MUDROOM 210 STONE TILE HALLWAY 201 STONE TILE STAIR 200 CARPET ENTRY CLOSET 202 STONE TILE ENTRY 203 STONE TILE MASTER CLOSET 205 CARPET MASTER BEDROOM 204 CARPETMASTER BATH 206 TILE UP DN 12 R @ 7 " 10 - 1 / 2 " T T Y P 14 R @ 7 " 10 - 1 / 2 " T T Y P 6 8 2 3 4 5 10 11 12 14 15 16 17 21 2 3 5 14 15 16 17 2 3 14 16 18 19 2 3 4 14 15 16 2 3 4 14 15 16 17 2 3 4 14 15 16 17 2 3 4 14 15 16 17 2 3 4 7 14 15 16 17 2 3 4 10 11 12 13 14 15 16 17 23 24 25 2 3 8 14 15 16 17 2 3 14 15 16 17 22 DOOR TO BE REPLACED WITH WALL F.P. TO BE REPLACED EXISTING FLUE TO REMAIN 211A 210A 210B 207A209A 208A 206B 206A 205A 202A 204A 203A 204B 204C 206C TILE CPT CPT TILE CPT TILE CP T TI L E CP T TI L E CP T TI L E WO O D TI L E WO O D TI L E 9 T.O. MAIN LEVEL F.F. +100'-0" DN F.P. TO BE ELININATED EXISTING PARTITION WALLS BETWEEN UNITS ASSUMED TO BE RATED NOT TO BE DISTURBED UPPER LEVEL PRIMARY DECK DRAIN TERMINATION POINT. EXISTING DECK DRAIN TIES INTO EXISTING GUTTER SYSTEM. 0 2 4 8 Scale: 1/4" = 1'-0" EXISTING-DEMO MAIN LEVEL FLOOR PLAN 1/4" = 1'-0" 1 A-110X PROJECT SCALE 1/4" = 1'-0" 18011.00 A-110X EXISTING-DEMO MAIN LEVEL FLOOR PLAN CO P Y R I G H T 2 0 1 9 T H U N D E R B O W L A R C H I T E C T S AS P E N , C O L O R A D O PA R C E L I D # 27 3 7 0 7 3 6 1 0 0 1 72 8 E . H O P K I N S A V E . C TH U N D E R B O W L AR C H I T E C T S THUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 02/13/2019 PERMIT SET 07/10/2019 CHANGE ORDER #1 1 DEMOLITION NOTES 1.FURNISH EQUIPMENT AND PERFORM LABOR REQUIRED TO EXECUTE THE CONTRACT DOCUMENTS. 2.PROTECT EXISTING WORK TO REMAIN INCLUDING DUST CONTROL. 3.THE DRAWINGS DO NOT NECESSARILY INDICATE THE FULL EXTENT OF THE WORK TO BE PERFORMED. INSPECT THE EXISTING CONSTRUCTION CAREFULLY TO DETERMINE THE FULL EXTENT OF WORK TO BE PERFORMED AND THE CHALLENGES INVOLVED. 4.DO NOT ALLOWED DEMOLISHED DEBRIS TO ACCUMULATE ON SITE BEYOND A REASONABLE AMOUNT. MAINTAIN PROGRESSIVE DISPOSE OF DEBRIS IN A LEGAL MANNER. 5.REMOVAL OF ALL HAZARDOUS MATERIALS IS THE RESPONSIBILITY OF THE OWNER. SHOULD THE CONTRACTOR ENCOUNTER ANY HAZARDOUS MATERIALS WHILE EXECUTING DEMOLITION, THEY SHOULD CONTACT THE OWNER IMMEDIATELY. 6.VERIFY ALL SALVAGING REQUIREMENTS WITH THE OWNER PRIOR TO DEMOLITION. 7.NOTIFY OWNER 48 HOURS PRIOR TO ANY UTILITY SERVICE DISRUPTION. 8.COORDINATE EXTENT OF ALL STRUCTURAL DEMOLITION WITH THE STRUCTURAL DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR DESIGN AND IMPLEMENTATION OF TEMPORARY SHORING AND BRACING AS REQUIRED. 9.VERIFY EXTENT OF WALL AND ROOF REMOVAL WITH STRUCTURAL ENGINEER. 10.PRIOR TO COMMENCEMENT OF DEMOLITION, EXTENT OF STRUCTURE AND/OR FINISH TO BE REMOVED MUST BE VERIFIED WITH BOTH THE OWNER AND ARCHITECT. 11.PROVIDE NECESSARY EROSION CONTROL PER LANDSCAPING OR CIVIL DRAWINGS. LEGEND SEE A0.00 FOR SYMBOLS NOT SHOWN HERE. (E) CONST. TO BE REMOVED OR NEW MASONRY WALL PARTITION WALL BETWEEN UNITS NEW CONSTRUCTION EXISTING CONSTRUCTION AREA OF WORK KEY NOTES LEGEND: MAIN LEVEL EXISTING NOT USED1 2 3 4 5 REPLACE FLOORING ELIMINATE CURVED WALLS AND ARCHES REDESIGN MUDROOM AREA REMOVE DUMBWAITER - CHASE T.B.D.6 ELIMINATE FIREPLACE7 8 BUILT-IN / STORAGE AREA TO BE ADDED 9 BATHROOM TO BE UPDATED10 FIXTURES TO BE REPLACED 11 VANITY TO BE RELOCATED DOUBLE VANITY TO BE ADDED 12 BATHROOM FINISHES TO BE UPDATED UPDATE LIGHTING 13 UPDATE WALL FINISHES UPDATE SWITCHES / OUTLETS/ SWITCH PLATES 14 15 UPDATE BASE AND TRIM16 UPDATE DOOR HARDWARE17 ELIMINATE CLOSET UPDATE STAIR TREAD18 UPDATE STAIR HANDRAIL19 NOT USED20 REPLACE DOOR WITH WALL21 REPLACE F.P. EXISTING FLUE TO REMAIN22 TUB TO BE REMOVED FREESTANDING TUB TO BE ADDED23 BIDET TO BE ELIMINATED24 LARGER SHOWER TO BE ADDED25 N 1 1 1 1 10/09/2019 1 2 3 4 5 A B C 74'-1 15/16" 18'-11 5/8"41'-5 3/4"6'-1 3/4"7'-6 13/16" 19 ' - 2 7 / 1 6 " 24 ' - 0 " 4' - 9 1 / 2 " 7'-2-1/2" GB 8'-11" GB 8'-11" GB 8'-11" GB 8'-11" GB 8'-11" GB 8'-11" GB 8'-11" GB 8'-11" GB C.O. S.D. F C.O. S.D. C.O. S.D. F C.O. S.D. GARAGE 211 MUDROOM 210 GUEST BATH 209 GUEST MASTER 207 GUEST CLOSET 208 MASTER BATH 206 STAIR 200 HALLWAY 201 ENTRY 203 MASTER BEDROOM 204 MASTER CLOSET 205 ENTRY CLOSET 202C.O. S.D. 0 2 4 8 Scale: 1/4" = 1'-0" EXISTING-DEMO MAIN LEVEL RCP 1/4" = 1'-0" 1 A-111X PROJECT SCALE 1/4" = 1'-0" 18011.00 A-111X EXISTING-DEMO MAIN LEVEL RCP CO P Y R I G H T 2 0 1 9 T H U N D E R B O W L A R C H I T E C T S AS P E N , C O L O R A D O PA R C E L I D # 27 3 7 0 7 3 6 1 0 0 1 72 8 E . H O P K I N S A V E . C TH U N D E R B O W L AR C H I T E C T S THUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 02/13/2019 PERMIT SET 07/10/2019 CHANGE ORDER #1 1 N LEGEND SEE COVER SHEET FOR SYMBOLS NOT SHOWN HERE. REFLECTED CEILING PLAN GENERAL NOTES SP ALL DIMENSIONS ARE TO FACE OF FIN., CENTER OF FIXTURE/REGISTER UNLESS NOTED OTHERWISE. VERIFY IN FIELD ALL EXISTING DIMENSIONS. LIGHT FIXTURES SHOWN ON THIS PLAN ARE FOR REFERENCE ONLY. SEE LIGHTING DRAWINGS FOR TYPE, LOCATION, AND CIRCUITING. ALSO SEE INTERIOR ELEVATIONS FOR LOCATION OF SCONCES, TYP. PAINT ALL RECESSED CAN TRIMS/MECHANICAL GRILLES THE COLOR OF THE CEILING IN WHICH THEY APPEAR. COORDINATE FIXTURE LAYOUT WITH ALL EXISTING AND PROPOSED STRUCTURE. ALL EXISTING LIGHTING TO BE REPLACED 1. 2. 3. 4. 5. 6. 7. +8'-0" SEE LIGHTING DRAWINGS FOR ALL LIGHT SYMBOLS AIR OUTLET, VERIFY WITH MECH. SUB. AIR INTAKE, VERIFY WITH MECH. SUB. CEILING MOUNTED SMOKE DETECTOR SPEAKER, VERIFY AV REQUIREMENTS WITH OWNER CEILING/SOFFIT HEIGHT SYMBOL C.O. S.D. F EXHAUST FAN (110 V) FLUORESCENT LIGHT FIXTURE RECESSED DOWNLIGHT DIRECTIONAL RECESSED DOWNLIGHT SURFACE MOUNTED DOWNLIGHT EXPOSED SPRINKLER HEAD RECESSED SPRINKLER HEAD WALL MOUNTED FIXTURE LARGE PENDANT LIGHT FIXTURE 1 1 10/09/2019 1 2 3 4 5 A B C 74'-1 15/16" 18'-11 5/8"41'-5 3/4"6'-1 3/4"7'-6 13/16" 19 ' - 2 7 / 1 6 " 24 ' - 0 " 4' - 9 1 / 2 " 301A 302A 300 1 2 3 4 13 14 15 6 2 3 13 14 15 17 18 2 3 13 14 15 17 18 1 3 10 11 12 2 3 13 14 15 16 DINING ROOM 303 WOOD KITCHEN 304 WOOD STAIR 300 CARPET LIVING ROOM 301 WOOD POWDER ROOM 302 WOOD DECK 305 CONCRETE DN 12 R @ 7 " 10 - 1 / 2 " T T Y P CP T WO O D CONCWOOD WALLS TO BE REMOVED F.P TO BE REPLACED EXISTING FLUE TO REMAIN POWDER ROOM TO BE RELOCATED T.O. UPPER LEVEL F.F. +110'-3" WALLS TO BE ELIMINATED 4 EXISTING PARTITION WALLS BETWEEN UNITS ASSUMED TO BE RATED NOT TO BE DISTURBED UPPER LEVEL DECK SCUPPER TERMINATION POINT. UPPER LEVEL PRIMARY DECK DRAIN. SEE SHEET A-110X FOR TERMINATION POINT 0 2 4 8 Scale: 1/4" = 1'-0" EXISTING-DEMO UPPER LEVEL FLOOR PLAN 1/4" = 1'-0" 1 A-120X PROJECT SCALE 1/4" = 1'-0" 18011.00 A-120X EXISTING-DEMO UPPER LEVEL FLOOR PLAN CO P Y R I G H T 2 0 1 9 T H U N D E R B O W L A R C H I T E C T S AS P E N , C O L O R A D O PA R C E L I D # 27 3 7 0 7 3 6 1 0 0 1 72 8 E . H O P K I N S A V E . C TH U N D E R B O W L AR C H I T E C T S THUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 02/13/2019 PERMIT SET 07/10/2019 CHANGE ORDER #1 1 DEMOLITION NOTES 1.FURNISH EQUIPMENT AND PERFORM LABOR REQUIRED TO EXECUTE THE CONTRACT DOCUMENTS. 2.PROTECT EXISTING WORK TO REMAIN INCLUDING DUST CONTROL. 3.THE DRAWINGS DO NOT NECESSARILY INDICATE THE FULL EXTENT OF THE WORK TO BE PERFORMED. INSPECT THE EXISTING CONSTRUCTION CAREFULLY TO DETERMINE THE FULL EXTENT OF WORK TO BE PERFORMED AND THE CHALLENGES INVOLVED. 4.DO NOT ALLOWED DEMOLISHED DEBRIS TO ACCUMULATE ON SITE BEYOND A REASONABLE AMOUNT. MAINTAIN PROGRESSIVE DISPOSE OF DEBRIS IN A LEGAL MANNER. 5.REMOVAL OF ALL HAZARDOUS MATERIALS IS THE RESPONSIBILITY OF THE OWNER. SHOULD THE CONTRACTOR ENCOUNTER ANY HAZARDOUS MATERIALS WHILE EXECUTING DEMOLITION, THEY SHOULD CONTACT THE OWNER IMMEDIATELY. 6.VERIFY ALL SALVAGING REQUIREMENTS WITH THE OWNER PRIOR TO DEMOLITION. 7.NOTIFY OWNER 48 HOURS PRIOR TO ANY UTILITY SERVICE DISRUPTION. 8.COORDINATE EXTENT OF ALL STRUCTURAL DEMOLITION WITH THE STRUCTURAL DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR DESIGN AND IMPLEMENTATION OF TEMPORARY SHORING AND BRACING AS REQUIRED. 9.VERIFY EXTENT OF WALL AND ROOF REMOVAL WITH STRUCTURAL ENGINEER. 10.PRIOR TO COMMENCEMENT OF DEMOLITION, EXTENT OF STRUCTURE AND/OR FINISH TO BE REMOVED MUST BE VERIFIED WITH BOTH THE OWNER AND ARCHITECT. 11.PROVIDE NECESSARY EROSION CONTROL PER LANDSCAPING OR CIVIL DRAWINGS. LEGEND SEE A0.00 FOR SYMBOLS NOT SHOWN HERE. (E) CONST. TO BE REMOVED OR NEW MASONRY WALL PARTITION WALL BETWEEN UNITS NEW CONSTRUCTION EXISTING CONSTRUCTION AREA OF WORK KEY NOTES LEGEND: UPPER LEVEL EXISTING REMOVE PARTITION1 2 3 REPLACE FLOORING REMOVE DUMBWAITER - CHASE T.B.D.6 ELIMINATE FIREPLACE7 8 BUILT-IN / STORAGE AREA TO BE ADDED 9 BATHROOM TO BE RELOCATED10 FIXTURES TO BE REPLACED 11 12 BATHROOM FINISHES TO BE UPDATED UPDATE LIGHTING UPDATE WALL FINISHES UPDATE SWITCHES / OUTLETS/ SWITCH PLATES 13 14 UPDATE BASE AND TRIM15 UPDATE DOOR HARDWARE16 ELIMINATE CLOSET UPDATE STAIR TREAD17 UPDATE STAIR HANDRAIL18 NOT USED19 REPLACE F.P. EXISTING FLUE TO REMAIN20 UPDATE KITCHEN LOCATION, LAYOUT AND CABINETRY4 REPLACE APPLIANCES RANGE TO REMAIN5 NOT USED21 NOT USED22 N 1 1 1 1 10/09/2019 1 2 3 4 5 A B C 74'-1 15/16" 18'-11 5/8"41'-5 3/4"6'-1 3/4"7'-6 13/16" 19 ' - 2 7 / 1 6 " 24 ' - 0 " 4' - 9 1 / 2 " C.O. S.D. VARIES LIVING ROOM 301 7'-9" GB POWDER ROOM 302 VARIES DINING ROOM 303 VARIES KITCHEN 304 STAIR 300 DECK 305 SL O P E SL O P E 0 2 4 8 Scale: 1/4" = 1'-0" EXISTING-DEMO UPPER LEVEL RCP 1/4" = 1'-0" 1 A-121X PROJECT SCALE 1/4" = 1'-0" 18011.00 A-121X EXISTING-DEMO UPPER LEVELR RCP CO P Y R I G H T 2 0 1 9 T H U N D E R B O W L A R C H I T E C T S AS P E N , C O L O R A D O PA R C E L I D # 27 3 7 0 7 3 6 1 0 0 1 72 8 E . H O P K I N S A V E . C TH U N D E R B O W L AR C H I T E C T S THUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 02/13/2019 PERMIT SET 07/10/2019 CHANGE ORDER #1 1 N LEGEND SEE COVER SHEET FOR SYMBOLS NOT SHOWN HERE. REFLECTED CEILING PLAN GENERAL NOTES SP ALL DIMENSIONS ARE TO FACE OF FIN., CENTER OF FIXTURE/REGISTER UNLESS NOTED OTHERWISE. VERIFY IN FIELD ALL EXISTING DIMENSIONS. LIGHT FIXTURES SHOWN ON THIS PLAN ARE FOR REFERENCE ONLY. SEE LIGHTING DRAWINGS FOR TYPE, LOCATION, AND CIRCUITING. ALSO SEE INTERIOR ELEVATIONS FOR LOCATION OF SCONCES, TYP. PAINT ALL RECESSED CAN TRIMS/MECHANICAL GRILLES THE COLOR OF THE CEILING IN WHICH THEY APPEAR. COORDINATE FIXTURE LAYOUT WITH ALL EXISTING AND PROPOSED STRUCTURE. ALL EXISTING LIGHTING TO BE REPLACED 1. 2. 3. 4. 5. 6. 7. +8'-0" SEE LIGHTING DRAWINGS FOR ALL LIGHT SYMBOLS AIR OUTLET, VERIFY WITH MECH. SUB. AIR INTAKE, VERIFY WITH MECH. SUB. CEILING MOUNTED SMOKE DETECTOR SPEAKER, VERIFY AV REQUIREMENTS WITH OWNER CEILING/SOFFIT HEIGHT SYMBOL C.O. S.D. F EXHAUST FAN (110 V) FLUORESCENT LIGHT FIXTURE RECESSED DOWNLIGHT DIRECTIONAL RECESSED DOWNLIGHT SURFACE MOUNTED DOWNLIGHT EXPOSED SPRINKLER HEAD RECESSED SPRINKLER HEAD WALL MOUNTED FIXTURE LARGE PENDANT LIGHT FIXTURE 1 1 10/09/2019 1 2 3 4 5 A B C 74'-1 15/16" 18'-11 5/8"41'-5 3/4"6'-1 3/4"7'-6 13/16" 19 ' - 2 7 / 1 6 " 24 ' - 0 " 4' - 9 1 / 2 " MEDIA ROOM 112 CARPET MECHANICAL 111 CONCRETE LAUNDRY 110 TILE BUNK ROOM 109 CARPET STORAGE 108 BEDROOM 2 105 CARPET BEDROOM 1 104 CARPET CLOSET 1 103 CARPET BATH 1 102 TILE BATH 2 107 TILE HALLWAY 101 CARPET 110A 111A 109A 105A 102A 103A 104A 108A 107A 107B 106A STAIR 100 CARPETDN 4 17 2 3 5 12 14 15 16 17 2 3 8 14 15 16 17 2 3 10 11 12 13 14 15 16 17 2 3 14 15 16 17 2 3 14 15 16 17 2 3 14 15 16 17 2 3 10 11 12 14 15 16 17 2 3 14 15 16 17 2 3 14 15 16 2 3 9 14 15 16 2 3 14 15 16 18 19 1 2 3 9 15 16 17 3R @ 7" 12" T TYP T.O. LOWER LEVEL F.F. +89'-10"UP 14 R @ 7 " 10 - 1 / 2 " T T Y P CP T TI L E CP T TI L E TILECONC TILECPT CPTTILE CP T TI L E 113A LINEN CLOSET 113 CARPET CLOSET 2 106 CARPET 4' - 4 3 / 8 " 14 NEW BUILT-IN 1 17 ' - 8 7 / 8 " 14'-5 3/4" 6' - 3 1 3 / 1 6 " 4' - 4 3 / 8 " 1 9 NEW BUILT-IN 1 1'-6 1/8" EXISTING PARTITION WALLS BETWEEN UNITS ASSUMED TO BE RATED NOT TO BE DISTURBED CP T TI L E 9' - 8 1 / 2 " 4'-3 1/2" 0 2 4 8 Scale: 1/4" = 1'-0" PROPOSED LOWER LEVEL FLOOR PLAN 1/4" = 1'-0" 1 A-100 PROJECT SCALE 1/4" = 1'-0" 18011.00 A-100 PROPOSED LOWER LEVEL FLOOR PLAN CO P Y R I G H T 2 0 1 9 T H U N D E R B O W L A R C H I T E C T S AS P E N , C O L O R A D O PA R C E L I D # 27 3 7 0 7 3 6 1 0 0 1 72 8 E . H O P K I N S A V E . C TH U N D E R B O W L AR C H I T E C T S THUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 02/13/2019 PERMIT SET 07/10/2019 CHANGE ORDER #1 1 ALL WALLS WITH SHEAR PLYWOOD SHALL HAVE A CONTINUOUS FLUSH FINISH. FURR WALLS OR CONTINUE PLYWOOD TO MAINTAIN THE REQUIRED FLUSH FINISH. OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACES WILL BE FLUSH. PROVIDE BLOCKING FOR ALL ARTWORK, TOWEL BARS AND TISSUE HOLDERS, TYP. PROVIDE WATER RESISTANT GYPSUM BOARD BEHIND ALL PLUMBING FIXTURES, UNDER AND AROUND TUB AND SHOWER ENCLOSURES TO A HEIGHT OF 70" MIN. ABOVE THE DRAIN INLET. , OR APPROVED BACKER BOARD UNDER TILE. FINISH MATERIALS FOR ALL BATHS, SHOWERS, WALLS AT SHOWER ENCLOSURES SHALL HAVE A SMOOTH, HARD, NON-ABSORBANT SURFACE SUCH AS TILES/CERAMIC TILES, PORTLANT CEMENT OR EQ. 1. 2. 3. 4. 5. LEGEND SEE A0.00 FOR SYMBOLS NOT SHOWN HERE. FLOOR PLAN GENERAL NOTES (E) CONST. TO BE REMOVED PARTITION WALL BETWEEN UNITS EXISTING CONSTRUCTION NEW CONSTRUCTION KEY NOTES LEGEND: LOWER LEVEL PROPOSED NEW WALLS TO BE CONSTRUCTED1 2 3 4 5 NEW FLOORING TO BE INSTALLED 6 7 NEW BEDROOM TO BE CONSTRUCTED8 9 BATHROOM TO BE UPDATED10 NEW FIXTURES TO BE INSTALLED 11 NEW DOUBLE VANITY 12 NEW BATHROOM FINISHES NEW LIGHTING 13 NEW WALL FINISHES UPDATE SWITCHES / OUTLETS/ SWITCH PLATES 14 15 NEW BASE AND TRIM16 NEW DOORS/ DOOR HARDWARE17 NEW UPDATED STAIR TREADS FINISH18 NEW STAIR HANDRAIL19 NEW MECHANICAL EQUIPMENT NEW BUILT-IN CABINETRY NEW LAUNDRY ROOM LAYOUT NOT USED NOT USED N 1 1 1 10/09/2019 1 2 3 4 5 A B C 74'-1 15/16" 18'-11 5/8"41'-5 3/4"6'-1 3/4"7'-6 13/16" 19 ' - 2 7 / 1 6 " 24 ' - 0 " 4' - 9 1 / 2 " LOUNGE 112 MECHANICAL 111 LAUNDRY 110 BUNK ROOM 109 CLOSET 2 106STORAGE 108 BEDROOM 2 105 BEDROOM 1 104 CLOSET 1 103 BATH 1 102 BATH 2 107 HALLWAY 101 STAIR 100 7'-7" GB 7'-7" GB 7'-11" GB 8'-10" GB 8'-10" GB 8'-10" GB 8'-10" GB 8'-10" GB 8'-10" GB 8'-10" GB 8'-10" GB C.O. S.D. C.O. S.D. C.O. S.D. F F C.O. S.D. LINEN CLOSET 113 F C.O. S.D. 0 2 4 8 Scale: 1/4" = 1'-0" PROPOSED LOWER LEVEL RCP 1/4" = 1'-0" 1 A-101 PROJECT SCALE 1/4" = 1'-0" 18011.00 A-101 PROPOSED LOWER LEVEL RCP CO P Y R I G H T 2 0 1 9 T H U N D E R B O W L A R C H I T E C T S AS P E N , C O L O R A D O PA R C E L I D # 27 3 7 0 7 3 6 1 0 0 1 72 8 E . H O P K I N S A V E . C TH U N D E R B O W L AR C H I T E C T S THUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 02/13/2019 PERMIT SET 07/10/2019 CHANGE ORDER #1 1 N LEGEND SEE COVER SHEET FOR SYMBOLS NOT SHOWN HERE. REFLECTED CEILING PLAN GENERAL NOTES SP ALL DIMENSIONS ARE TO FACE OF FIN., CENTER OF FIXTURE/REGISTER UNLESS NOTED OTHERWISE. VERIFY IN FIELD ALL EXISTING DIMENSIONS. LIGHT FIXTURES SHOWN ON THIS PLAN ARE FOR REFERENCE ONLY. SEE LIGHTING DRAWINGS FOR TYPE, LOCATION, AND CIRCUITING. ALSO SEE INTERIOR ELEVATIONS FOR LOCATION OF SCONCES, TYP. PAINT ALL RECESSED CAN TRIMS/MECHANICAL GRILLES THE COLOR OF THE CEILING IN WHICH THEY APPEAR. COORDINATE FIXTURE LAYOUT WITH ALL EXISTING AND PROPOSED STRUCTURE. 1. 2. 3. 4. 5. 6. +8'-0" SEE LIGHTING DRAWINGS FOR ALL LIGHT SYMBOLS AIR OUTLET, VERIFY WITH MECH. SUB. AIR INTAKE, VERIFY WITH MECH. SUB. CEILING MOUNTED SMOKE DETECTOR SPEAKER, VERIFY AV REQUIREMENTS WITH OWNER CEILING/SOFFIT HEIGHT SYMBOL C.O. S.D. F EXHAUST FAN (110 V) FLUORESCENT LIGHT FIXTURE RECESSED DOWNLIGHT DIRECTIONAL RECESSED DOWNLIGHT SURFACE MOUNTED DOWNLIGHT EXPOSED SPRINKLER HEAD RECESSED SPRINKLER HEAD WALL MOUNTED FIXTURE LARGE PENDANT LIGHT FIXTURE 1 1 10/09/2019 1 2 3 4 5 A B C 74'-1 15/16" 18'-11 5/8"41'-5 3/4"6'-1 3/4"7'-6 13/16" 19 ' - 2 7 / 1 6 " 24 ' - 0 " 4' - 9 1 / 2 " 210A 202A 204A 203A 206A 206B 209A 207A 204B 204C 205A 22 3 14 15 16 17 3 5 10 11 12 14 15 16 17 2 3 5 21 2 3 14 15 16 18 19 2 3 14 15 16 2 3 14 15 16 17 14 15 16 17 2 3 14 15 16 17 22 2 3 14 15 16 17 823 13 10 11 12 14 15 16 17 23 25 8 2 3 15 16 17 14 DN4R @ 7" 9" T TYP UP DN 12 R @ 7 " 10 - 1 / 2 " T T Y P 14 R @ 7 " 10 - 1 / 2 " T T Y P CP T ST O N E CP T ST O N E GARAGE 211 CONCRETE GUEST MASTER 207 WOOD GUEST BATH 209 TILE MUDROOM 210 STONE HALLWAY 201 STONE ENTRY CLOSET 202 STONE ENTRY 203 STONE MASTER CLOSET 205 WOOD MASTER BEDROOM 204 WOOD MASTER BATH 206 TILE WO O D ST O N E TILESTONE TILE TILEWOOD WO O D ST O N E WO O D TI L E T.O. MAIN LEVEL F.F. +100'-0" STAIR 200 CARPET WOOD GUEST CLOSET 208 WOOD TILE WOOD WO O D TI L E DN EXISTING PARTITION WALLS BETWEEN UNITS ASSUMED TO BE RATED NOT TO BE DISTURBED UPPER LEVEL PRIMARY DECK DRAIN TERMINATION POINT. EXISTING DECK DRAIN TIES INTO EXISTING GUTTER SYSTEM. 0 2 4 8 Scale: 1/4" = 1'-0" PROPOSED MAIN LEVEL FLOOR PLAN 1/4" = 1'-0" 1 A-110 PROJECT SCALE 1/4" = 1'-0" 18011.00 A-110 PROPOSED MAIN LEVEL FLOOR PLAN CO P Y R I G H T 2 0 1 9 T H U N D E R B O W L A R C H I T E C T S AS P E N , C O L O R A D O PA R C E L I D # 27 3 7 0 7 3 6 1 0 0 1 72 8 E . H O P K I N S A V E . C TH U N D E R B O W L AR C H I T E C T S THUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 02/13/2019 PERMIT SET 07/10/2019 CHANGE ORDER #1 1 ALL WALLS WITH SHEAR PLYWOOD SHALL HAVE A CONTINUOUS FLUSH FINISH. FURR WALLS OR CONTINUE PLYWOOD TO MAINTAIN THE REQUIRED FLUSH FINISH. OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACES WILL BE FLUSH. PROVIDE BLOCKING FOR ALL ARTWORK, TOWEL BARS AND TISSUE HOLDERS, TYP. PROVIDE WATER RESISTANT GYPSUM BOARD BEHIND ALL PLUMBING FIXTURES, UNDER AND AROUND TUB AND SHOWER ENCLOSURES TO A HEIGHT OF 70" MIN. ABOVE THE DRAIN INLET. , OR APPROVED BACKER BOARD UNDER TILE. FINISH MATERIALS FOR ALL BATHS, SHOWERS, WALLS AT SHOWER ENCLOSURES SHALL HAVE A SMOOTH, HARD, NON-ABSORBANT SURFACE SUCH AS TILES/CERAMIC TILES, PORTLANT CEMENT OR EQ. 1. 2. 3. 4. 5. LEGEND SEE A0.00 FOR SYMBOLS NOT SHOWN HERE. FLOOR PLAN GENERAL NOTES (E) CONST. TO BE REMOVED PARTITION WALL BETWEEN UNITS EXISTING CONSTRUCTION NEW CONSTRUCTION KEY NOTES LEGEND: MAIN LEVEL PROPOSED NOT USED1 2 3 4 5 NEW FLOORING TO BE INSTALLED NEW MUDROOM LAYOUT NOT USED6 NOT USED7 8 NEW MILLWORK 9 BATHROOM TO BE UPDATED10 NEW FIXTURES TO BE INSTALLED 11 NEW DOUBLE VANITY 12 NEW BATHROOM FINISHES NEW LIGHTING 13 NEW WALL FINISHES UPDATE SWITCHES / OUTLETS/ SWITCH PLATES 14 15 NEW BASE AND TRIM16 NEW DOORS/ DOOR HARDWARE17 NEW CLOSET TO BE CONSTRUCTED NEW UPDATED STAIR TREADS AND FINISH18 NEW STAIR HANDRAIL19 NOT USED20 NEW WALL21 NEW F.P. EXISTING FLUE TO REMAIN22 NEW FREESTANDING TUB23 NOT USED24 NEW SHOWER ENCLOSURE25 NOT USED N 1 1 1 1 1 1 10/09/2019 1 2 3 4 5 A B C 74'-1 15/16" 18'-11 5/8"41'-5 3/4"6'-1 3/4"7'-6 13/16" 19 ' - 2 7 / 1 6 " 24 ' - 0 " 4' - 9 1 / 2 " GUEST CLOSET 208 7'-2-1/2" GB 8'-11" GB 8'-11" GB 8'-11" GB 8'-11" GB 8'-11" GB 8'-11" GB 8'-11" GB 8'-11" GB C.O. S.D. F C.O. S.D. C.O. S.D. C.O. S.D. GARAGE 211 MUDROOM 210 GUEST BATH 209 GUEST MASTER 207 MASTER BATH 206 STAIR 200 HALLWAY 201 ENTRY 203 MASTER BEDROOM 204 MASTER CLOSET 205 ENTRY CLOSET 202 C.O. S.D. F 0 2 4 8 Scale: 1/4" = 1'-0" PROPOSED MAIN LEVEL RCP 1/4" = 1'-0" 1 A-111 PROJECT SCALE 1/4" = 1'-0" 18011.00 A-111 PROPOSED MAIN LEVEL RCP CO P Y R I G H T 2 0 1 9 T H U N D E R B O W L A R C H I T E C T S AS P E N , C O L O R A D O PA R C E L I D # 27 3 7 0 7 3 6 1 0 0 1 72 8 E . H O P K I N S A V E . C TH U N D E R B O W L AR C H I T E C T S THUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 02/13/2019 PERMIT SET 07/10/2019 CHANGE ORDER #1 1 N LEGEND SEE COVER SHEET FOR SYMBOLS NOT SHOWN HERE. REFLECTED CEILING PLAN GENERAL NOTES SP ALL DIMENSIONS ARE TO FACE OF FIN., CENTER OF FIXTURE/REGISTER UNLESS NOTED OTHERWISE. VERIFY IN FIELD ALL EXISTING DIMENSIONS. LIGHT FIXTURES SHOWN ON THIS PLAN ARE FOR REFERENCE ONLY. SEE LIGHTING DRAWINGS FOR TYPE, LOCATION, AND CIRCUITING. ALSO SEE INTERIOR ELEVATIONS FOR LOCATION OF SCONCES, TYP. PAINT ALL RECESSED CAN TRIMS/MECHANICAL GRILLES THE COLOR OF THE CEILING IN WHICH THEY APPEAR. COORDINATE FIXTURE LAYOUT WITH ALL EXISTING AND PROPOSED STRUCTURE. 1. 2. 3. 4. 5. 6. +8'-0" SEE LIGHTING DRAWINGS FOR ALL LIGHT SYMBOLS AIR OUTLET, VERIFY WITH MECH. SUB. AIR INTAKE, VERIFY WITH MECH. SUB. CEILING MOUNTED SMOKE DETECTOR SPEAKER, VERIFY AV REQUIREMENTS WITH OWNER CEILING/SOFFIT HEIGHT SYMBOL C.O. S.D. F EXHAUST FAN (110 V) FLUORESCENT LIGHT FIXTURE RECESSED DOWNLIGHT DIRECTIONAL RECESSED DOWNLIGHT SURFACE MOUNTED DOWNLIGHT EXPOSED SPRINKLER HEAD RECESSED SPRINKLER HEAD WALL MOUNTED FIXTURE LARGE PENDANT LIGHT FIXTURE 1 1 10/09/2019 DW TR A S H 1 2 3 4 5 A B C 74'-1 15/16" 18'-11 5/8"41'-5 3/4"6'-1 3/4"7'-6 13/16" 19 ' - 2 7 / 1 6 " 24 ' - 0 " 4' - 9 1 / 2 " 301A DINING ROOM 303 WOOD KITCHEN 304 WOOD STAIR 300 CARPET LIVING ROOM 301 WOOD POWDER ROOM 302 WOOD DECK 305 CONCRETE T.O. UPPER LEVEL F.F. +110'-3" DN 12 R @ 7 " 10 - 1 / 2 " T T Y P CP T WO O D CONCWOOD 1 2 3 4 13 14 15 2 3 13 14 15 17 18 2 3 13 14 15 20 2 3 2 3 12 14 11 15 16 13 1 1 13 14 15 1 1 EXISTING PARTITION WALLS BETWEEN UNITS ASSUMED TO BE RATED NOT TO BE DISTURBED EXISTING UPPER LEVEL DECK SCUPPER TERMINATION POINT. SCUPPER TO REMAIN. EXISTING UPPER LEVEL PRIMARY DECK DRAIN. SEE SHEET A-110 FOR TERMINATION POINT NEW UPPER LEVEL PRIMARY DECK DRAIN. DRAINAGE TO TIE INTO EXISTING UPPER LEVEL DECK DRAIN. 0 2 4 8 Scale: 1/4" = 1'-0" PROPOSED UPPER LEVEL FLOOR PLAN 1/4" = 1'-0" 1 A-120 PROJECT SCALE 1/4" = 1'-0" 18011.00 A-120 PROPOSED UPPER LEVEL FLOOR PLAN CO P Y R I G H T 2 0 1 9 T H U N D E R B O W L A R C H I T E C T S AS P E N , C O L O R A D O PA R C E L I D # 27 3 7 0 7 3 6 1 0 0 1 72 8 E . H O P K I N S A V E . C TH U N D E R B O W L AR C H I T E C T S THUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 02/13/2019 PERMIT SET 07/10/2019 CHANGE ORDER #1 1 ALL WALLS WITH SHEAR PLYWOOD SHALL HAVE A CONTINUOUS FLUSH FINISH. FURR WALLS OR CONTINUE PLYWOOD TO MAINTAIN THE REQUIRED FLUSH FINISH. OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACES WILL BE FLUSH. PROVIDE BLOCKING FOR ALL ARTWORK, TOWEL BARS AND TISSUE HOLDERS, TYP. PROVIDE WATER RESISTANT GYPSUM BOARD BEHIND ALL PLUMBING FIXTURES, UNDER AND AROUND TUB AND SHOWER ENCLOSURES TO A HEIGHT OF 70" MIN. ABOVE THE DRAIN INLET. , OR APPROVED BACKER BOARD UNDER TILE. FINISH MATERIALS FOR ALL BATHS, SHOWERS, WALLS AT SHOWER ENCLOSURES SHALL HAVE A SMOOTH, HARD, NON-ABSORBANT SURFACE SUCH AS TILES/CERAMIC TILES, PORTLANT CEMENT OR EQ. 1. 2. 3. 4. 5. LEGEND SEE A0.00 FOR SYMBOLS NOT SHOWN HERE. FLOOR PLAN GENERAL NOTES (E) CONST. TO BE REMOVED PARTITION WALL BETWEEN UNITS EXISTING CONSTRUCTION NEW CONSTRUCTION KEY NOTES LEGEND: UPPER LEVEL PROPOSED NEW WALL TO BE CONSTRUCTED1 2 3 NEW FLOORING TO BE INSTALLED NOT USED6 NOT USED7 8 NEW MILLWORK 9 NOT USED10 NEW FIXTURES TO BE INSTALLED 11 12 NEW BATHROOM FINISHES NEW LIGHTING NEW WALL FINISHES UPDATE SWITCHES / OUTLETS/ SWITCH PLATES 13 14 NEW BASE AND TRIM15 NEW DOORS/ DOOR HARDWARE16 NEW POWDER ROOM TO BE CONSTRUCTED NEW UPDATED STAIR TREADS AND FINISH17 NEW STAIR HANDRAIL18 NOT USED19 NEW F.P. EXISTING FLUE TO REMAIN20 NEW KITCHEN DESIGN, NEW CABINETRY4 NEW APPLIANCES RANGE TO REMAIN5 NOT USED21 NOT USED22 N 1 1 1 10/09/2019 1 2 3 4 5 A B C 74'-1 15/16" 18'-11 5/8"41'-5 3/4"6'-1 3/4"7'-6 13/16" 19 ' - 2 7 / 1 6 " 24 ' - 0 " 4' - 9 1 / 2 " DW TR A S H 14'-9" GB LIVING ROOM 301 VARIES POWDER ROOM 302 VARIES DINING ROOM 303 VARIES KITCHEN 304 STAIR 300 DECK 305 F SL O P E SL O P E 0 2 4 8 Scale: 1/4" = 1'-0" PROPOSED UPPER LEVEL RCP 1/4" = 1'-0" 1 A-121 PROJECT SCALE 1/4" = 1'-0" 18011.00 A-121 PROPOSED UPPER LEVEL RCP CO P Y R I G H T 2 0 1 9 T H U N D E R B O W L A R C H I T E C T S AS P E N , C O L O R A D O PA R C E L I D # 27 3 7 0 7 3 6 1 0 0 1 72 8 E . H O P K I N S A V E . C TH U N D E R B O W L AR C H I T E C T S THUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 02/13/2019 PERMIT SET 07/10/2019 CHANGE ORDER #1 1 N LEGEND SEE COVER SHEET FOR SYMBOLS NOT SHOWN HERE. REFLECTED CEILING PLAN GENERAL NOTES SP ALL DIMENSIONS ARE TO FACE OF FIN., CENTER OF FIXTURE/REGISTER UNLESS NOTED OTHERWISE. VERIFY IN FIELD ALL EXISTING DIMENSIONS. LIGHT FIXTURES SHOWN ON THIS PLAN ARE FOR REFERENCE ONLY. SEE LIGHTING DRAWINGS FOR TYPE, LOCATION, AND CIRCUITING. ALSO SEE INTERIOR ELEVATIONS FOR LOCATION OF SCONCES, TYP. PAINT ALL RECESSED CAN TRIMS/MECHANICAL GRILLES THE COLOR OF THE CEILING IN WHICH THEY APPEAR. COORDINATE FIXTURE LAYOUT WITH ALL EXISTING AND PROPOSED STRUCTURE. 1. 2. 3. 4. 5. 6. +8'-0" SEE LIGHTING DRAWINGS FOR ALL LIGHT SYMBOLS AIR OUTLET, VERIFY WITH MECH. SUB. AIR INTAKE, VERIFY WITH MECH. SUB. CEILING MOUNTED SMOKE DETECTOR SPEAKER, VERIFY AV REQUIREMENTS WITH OWNER CEILING/SOFFIT HEIGHT SYMBOL C.O. S.D. F EXHAUST FAN (110 V) FLUORESCENT LIGHT FIXTURE RECESSED DOWNLIGHT DIRECTIONAL RECESSED DOWNLIGHT SURFACE MOUNTED DOWNLIGHT EXPOSED SPRINKLER HEAD RECESSED SPRINKLER HEAD WALL MOUNTED FIXTURE LARGE PENDANT LIGHT FIXTURE 1 1 10/09/2019 T.O. FOUNDATION WALL 100'-0" T.O. FINISHED FLOOR @ MAIN LEVEL 101'-2 1/8" B.O. CEILING @ MAIN LEVEL 110'-1 1/2" T.O. FINISHED FLOOR @ UPPER LEVEL 111'-2 1/8" T.O. EXTERIOR WALL @ UPPER LEVEL 120'-2 1/8" PEAK OF VAULTED CEILING 124'-11" ACB UNIT # 728 UNIT # 730 T.O. FOUNDATION WALL 100'-0" T.O. FINISHED FLOOR @ MAIN LEVEL 101'-2 1/8" B.O. CEILING @ MAIN LEVEL 110'-1 1/2" T.O. FINISHED FLOOR @ UPPER LEVEL 111'-2 1/8" ACB T.O. EXTERIOR WALL @ UPPER LEVEL 120'-2 1/8" AREAS OF WORK REPLACE EXISTING MAIN LEVEL PATIO DOORS. NEW DOORS TO MATCH SLIDING DOOR ON UPPER LEVEL NEW DOOR AND WINDOW LAYOUT TO REPLACE EXISTING. CONTRACTOR TO VERIFY EXISTING OPENING SIZES IN FIELD PEAK OF VAULTED CEILING 124'-11" 3' - 6 " NEW HANDRAIL TO MATCH EXISTING HEIGHT TO BE 42" ABOVE FINISHED DECK SURFACE UNIT # 728 UNIT # 730 204C 204B 301A301A 301B 301C 301E301D 301F 4' - 2 " 5'-0" PROJECT SCALE 1/4" = 1'-0" 18011.00 A-201 EXTERIOR ELEVATIONS CO P Y R I G H T 2 0 1 9 T H U N D E R B O W L A R C H I T E C T S AS P E N , C O L O R A D O PA R C E L I D # 27 3 7 0 7 3 6 1 0 0 1 72 8 E . H O P K I N S A V E . C TH U N D E R B O W L AR C H I T E C T S THUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 02/13/2019 PERMIT SET 07/10/2019 CHANGE ORDER #1 1 0 2 4 8 Scale: 1/4" = 1'-0" PROPOSED SOUTH ELEVATION 1/4" = 1'-0" 2 A-201 EXISTING SOUTH ELEVATION 1/4" = 1'-0" 1 A-201 1 10/09/2019 T.O. FOUNDATION WALL 100'-0" T.O. FINISHED FLOOR @ MAIN LEVEL 101'-2 1/8" B.O. CEILING @ MAIN LEVEL 110'-1 1/2" T.O. FINISHED FLOOR @ UPPER LEVEL 111'-2 1/8" T.O. EXTERIOR WALL @ UPPER LEVEL 120'-2 1/8" PEAK OF VAULTED CEILING 124'-11" 1 2 3 4 5 UNIT # 734 UNIT # 730 T.O. FOUNDATION WALL 100'-0" T.O. FINISHED FLOOR @ MAIN LEVEL 101'-2 1/8" B.O. CEILING @ MAIN LEVEL 110'-1 1/2" T.O. EXTERIOR WALL @ UPPER LEVEL 120'-2 1/8" PEAK OF VAULTED CEILING 124'-11" 1 2 3 4 5 T.O. FINISHED FLOOR @ UPPER LEVEL 111'-2 1/8" AREA OF WORK 3' - 6 " EXPANSION OF EXISTING UPPER LEVEL DECK OVER EXTERIOR PATIO. SLOPE AND FINISH TO MATCH EXISTING WEST SIDE OF DECK RAIL. VERIFY WITH ARCHITECT NEW HANDRAIL TO MATCH EXISTING HEIGHT TO BE 42" ABOVE FINISHED DECK SURFACE UNIT # 734 UNIT # 730 EXISTING DECK SCUPPER TO REMAIN EXISTING DECK DRAIN TERMINATION TIES INTO EXISTING GUTTER DRAINAGE SYSTEM PROJECT SCALE 1/4" = 1'-0" 18011.00 A-202 EXTERIOR ELEVATIONS CO P Y R I G H T 2 0 1 9 T H U N D E R B O W L A R C H I T E C T S AS P E N , C O L O R A D O PA R C E L I D # 27 3 7 0 7 3 6 1 0 0 1 72 8 E . H O P K I N S A V E . C TH U N D E R B O W L AR C H I T E C T S THUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 02/13/2019 PERMIT SET 07/10/2019 CHANGE ORDER #1 1 0 2 4 8 Scale: 1/4" = 1'-0" PROPOSED WEST ELEVATION 1/4" = 1'-0" 2 A-202 EXISTING WEST ELEVATION 1/4" = 1'-0" 1 A-202 1 1 10/09/2019 01 A-501 PROJECT SCALE VARIES 18011.00 A-501 ASSEMBLY DETAILS CO P Y R I G H T 2 0 1 9 T H U N D E R B O W L A R C H I T E C T S AS P E N , C O L O R A D O PA R C E L I D # 27 3 7 0 7 3 6 1 0 0 1 72 8 E . H O P K I N S A V E . C TH U N D E R B O W L AR C H I T E C T S THUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 02/13/2019 PERMIT SET 07/10/2019 CHANGE ORDER #1 1 NOT USED 3" = 1'-0" SLIDING DOOR HEAD AT HORIZONTAL WOOD SIDING 3" = 1'-0" SLIDING DOOR JAMB AT HORIZONTAL WOOD SIDING INTERIOR SE E S T R U C T U R A L 3" = 1'-0" SLIDING DOOR SILL AT HORIZONTAL WOOD SIDING INTERIOR EXTERIOR METAL FLASHING TO MATCH ROOF SEE INTERIORS FOR FINISH 3 4" HORIZONTAL EXTERIOR WOOD SIDING METAL FLASHING TO MATCH METAL ROOF LINE OF SILL 3 4" EXTERIOR HORIZONTAL WOOD SIDING EXTERIOR PATIO PER LANDSCAPE NON-EXPANDING SPRAY FOAM IN SHIM SPACE BACKER ROD & SEALANT @ FLASHING SEALANT AS REQUIRED SEALANT AS REQUIRED BACKER ROD & SEALANT NON-EXPANDING SPRAY FOAM IN SHIM SPACE BACKER ROD AND SEALANT SEE ASSEMBLY FOR BUILD-UP SLIDING DOOR PER SCHEDULE NON-EXPANDING SPRAY FOAM IN SHIM SPACE SLIDING DOOR PER SCHEDULE SEE ASSEMBLY FOR BUILD-UP EXTERIOR INTERIOR EXTERIOR SLIDING DOOR PER SCHEDULE SEALANT AS REQUIRED HEADER AS REQUIRED LINE OF SILL BEHIND INTERIOR FINISH PER PLANS 3" = 1'-0" TYP. WINDOW HEAD AT HORIZONTAL WOOD SIDING 3" = 1'-0" TYP. WINDOW JAMB AT HORIZONTAL WOOD SIDING INTERIOR 3" = 1'-0" TYP. WINDOW SILL AT HORIZONTAL WOOD SIDING INTERIOR EXTERIOR METAL FLASHING TO MATCH ROOF SEE INTERIORS FOR FINISH 3 4" HORIZONTAL EXTERIOR WOOD SIDING METAL FLASHING TO MATCH METAL ROOF SEE INTERIORS FOR FINISH LINE OF SILL 3 4" EXTERIOR VERTICAL WOOD SIDING METAL FLASHING TO MATCH ROOF NON-EXPANDING SPRAY FOAM IN SHIM SPACE 3 4" HORIZONTAL WOOD SIDING BACKER ROD & SEALANT SEALANT AS REQUIRED SEALANT AS REQUIRED BACKER ROD & SEALANT NON-EXPANDING SPRAY FOAM IN SHIM SPACE WINDOW PER SCHEDULE SEE ASSEMBLIES FOR BUILD-UP FINISH PER INTERIORS SEE ASSEMBLY FOR BUILD-UP WINDOW PER SCHEDULE NON-EXPANDING SPRAY FOAM IN SHIM SPACE WINDOW PER SCHEDULE SEE ASSEMBLY FOR BUILD-UP EXTERIOR INTERIOR EXTERIOR BACKER ROD AND SEALANT VERTICAL FURRING STRIPS TO ATTACH HORIZONTAL WOOD SIDING. SPACED 16" ON CENTER SEALANT AS REQUIRED 1-1/2" = 1'-0" TYP. DECK EXTERIOR EXTERIOR T.O. FINISH FLOOR T.O. PLY SE E S T R U C T U R A L 4" SOFFIT, PER INTERIOR FLOOR JOIST, PER STRUCTURAL PLYWOOD SUB-FLOOR TAPERED RIGID INSULATION, PER INSULATION SCHEDULE FLOOR DRAIN WATERPROOF MEMBRANE PLYWOOD GROUT STONE TILE, PER INTERIOR 1-1/2" = 1'-0" TYP. EXTERIOR DECK RAILING WATER RESISTANT BARRIER 3 4" HORIZONTAL WOOD SIDING, PER ELEVATIONS EXTERIOREXTERIOR 1 2" PLYWOOD SHEATHING 5-1 2" 2"x6" STUD WALL 1 2" PLYWOOD SHEATHING WATER RESISTANT BARRIER 3 4" HORIZONTAL WOOD SIDING, PER ELEVATIONS 02 A-501 03 A-501 04 A-501 05 A-501 06 A-501 07 A-501 08 A-501 09 A-501 10 A-501 11 A-501 3" = 1'-0" IN SWING DOOR HEAD AT WOOD SIDING 3" = 1'-0" IN SWING DOOR JAMB AT WOOD SIDING INTERIOR INTERIOR EXTERIOR METAL FLASHING TO MATCH ROOF SEE INTERIORS FOR FINISH EXTERIOR WOOD SIDING PER ELEVATIONS METAL FLASHING TO MATCH METAL ROOF EXTERIOR WOOD SIDING PER ELEVATIONS NON-EXPANDING SPRAY FOAM IN SHIM SPACE BACKER ROD & SEALANT @ FLASHING SEALANT AS REQUIRED SEALANT AS REQUIRED BACKER ROD & SEALANT NON-EXPANDING SPRAY FOAM IN SHIM SPACE BACKER ROD AND SEALANT IN-SWING DOOR PER SCHEDULE NON-EXPANDING SPRAY FOAM IN SHIM SPACE IN-SWING DOOR PER SCHEDULE SEE ASSEMBLY FOR BUILD-UP EXTERIOR INTERIOR EXTERIOR IN SWING DOOR PER SCHEDULE SEALANT AS REQUIRED HEADER AS REQUIRED LINE OF FRAME BEHIND INTERIOR FINISH PER PLANS EXTERIOR CONCRETE SLAB ON GRAD LANDING AT ENTRY SEE CIVIL ZIP SYSTEM TAPE OVER FLASHING 3" = 1'-0" IN SWING DOOR SILL AT WOOD SIDING12 A-501 13 A-501 7" 10 1/2" 1 3/8"3 7/8"1 3/8" 1" 3" 1-1/2" = 1'-0" TYP. STAIR TREAD DETAIL VERTICAL METAL ROD INFILL ±ø = 3 8" STEEL BASE PLATE TO MATCH HANDRAIL WOOD TREAD TO MATCH WOOD FLOORING 4" DIA. SPHERE 6" DIA. SPHERE 1-1/2" = 1'-0" TYP. INTERIOR HAND RAIL DETAIL METAL HANDRAIL VERTICAL METAL ROD INFILL ±ø = 3 8" STEEL BASE PLATE TO MATCH HANDRAIL WOOD FLOORING, SEE FINISH FLOOR PLAN 1/ 4 " 36 " 2 1/2" 1 3/8"3 7/8"1 3/8" WOOD EDGE CAP TO MATCH NOSING OF STAIRS 4" DIA. SPHERE 1 10/09/2019