Loading...
HomeMy WebLinkAboutFile Documents.754 Moore Dr.0034.2018 (12).ARBK RECEIVED VED Drawings A0.4 and A1.1 have been resubmitted per Zoning Department request. Fence and gate e.s !� that were previously shown at the driveway have been removed and site wall heights have been 1/2/2019 added to A1.1 0034-2018-ARBK BuildingComments 2 v';, — — BUILDI&'nerg-y Gode•Compliance_REScheck.754 Moore Drive_compliance-report-20180915.pdf(5) Page: 1 Revise RESch k to include the File Name: Energy Code Compliance_REScheck.754 Moore Drive_compliance-report-20180915.pdf frost protecte shallow "°°°E ° Subject: PlanCheck foundation ab shown in detail ,„, :Revise7.t.ckbincluEe the hoar Author: nickt 6/A7.10 �.n.tlanaiiow�°tl.ioaiaean , Color: • .In tlebil6lA1.10. See revised insulation depth to accurately represent shallow foundation as indicated under "Floor(F-1/F4b)-Main Level SOG" Page: 2 W-7, W-8,W-9b, W- , and File Name: Energy Code Compliance_REScheck.754 Moore likely others call for 13 cavity Drive_com pl iance-report-20180915.pdf Subject: PlanCheck and R-10 continu s.W-9a calls _ - Author: nickt for R-13 cavity ly. I don't see e_= Color: • these in the R scheck. See revised spray foam insulation depths and associated R-values revised in t e following wall assemblies to coordinate w/values represented in REScheck;W-7,W-8,W-8b,W-9b,and W-11.To clarify the comment associated to wall type"W-9a" indicating R-13 cavity insulation only-I believe this comment should actually apply to wall assembly type W-8a which is showing R-13 cavity only.This wall type is only used at chimney locations which exists outside of the buildings thermal envelope. --_, »° w° - - ° Page: 3"`"°""-" " "° Sign the Resche _ - ` File Name: Energy Code Compliance_REScheck.754 Moore -`"-_,—w-" " '' - ,_ Drive_compliance-report-20180915.pdf Subject: PlanCheck Signature ad ed. ._:; ,._.,::::. ; , ,:._v= ...� Author: nickt ( Color: • Page: 3 Some of your basement w s File Name: Energy Code Compliance_REScheck.754 Moore Drive_compliance-report-20180915.pdf have only R 19 cavity and o --s== ._ Subject: PlanCheck continuous insulation (W b). Author: nickt Wall assembly type W-1b/A7.1 only occurs as previously indicated o heet A2.0 on the _= ---- - Color: • West wall of A/V 036 near the exterior access stair for the baseme -this wall assembly has been revised to type W-2 to maintain consistency. dditionally,Wall type W-lb has been noted as"Not Used". Wall assembly types W-3 and W-3a/A7.1 only occurs on the ast and South walls of the egress well outside of the buildings thermal envelope.This Page: 3 Label all walls, roof ,floors, etc File Name: Energy Code Compliance_REScheck.754 Moore in the Rescheck w' h the Drive_compliance-report-20180915.pdf Subject: PlanCheck wall/roof/etc call t. For Author: nickt example, labe a crawlspace Color: ■ walls W-1. See revised REScheck for all associated assembly types i icated in parenthesis.