Loading...
HomeMy WebLinkAboutFile Documents.232 E Main St.0078-2020-BCHO (34)Structural Plan Review November 24, 2020 March 12, 2021 (Response Review) Review/Report is based on structural Construction Documents prepared by K. ENG Structural Consulting, LLC, dated 10/26/2020 (Construction Revisions), and architectural drawings prepared by Modif Architecture, dated 11/05/2020 (Construction Document Revision #7) and received via Bluebeam Studio. Structural drawings are stamped and signed by the engineer of record. Project Name: 232 E. Main Street Core and Shell Project Location: 232 E. Main Street, Aspen, CO 81611 Review based on International Building Code (IBC) Edition: 2015 Building Construction Type: The building is a two-story retail building with a basement below. The structure is framed with a concrete slab on metal deck on steel beams at the first, second, and roof levels. The foundation consists of continuous and pad footings, concrete basement walls, and a concrete slab on grade floor. The stair and elevator core walls are concrete below the main level and masonry above. Building Department Jurisdiction: Aspen Building Department Risk Category: II (IBC 2015 Table 1604.5) Basic Wind Speed: 115 mph (ultimate) Exposure: B Seismic Site Class: C Importance Factor: Ie = 1.00 Snow Load: 70 psf uniform Ground Snow Load: 100 psf Importance Factor: Is = 1.1 Frost Depth: 36” 03/15/2021 P a g e | 2 Structural Review Comments: Structural Drawings by K. ENG Structural Consulting 1. Sheet S-1.0 General Notes: Under “Design Criteria”, change the ACI 318-11 reference to ACI 318-14. Redo any calculations/design affected. Updated drawings provided. Comment addressed. 2. Sheet S-1.0 General Notes: Under “Design Criteria”, add the required uniform roof snow load of 70 psf. Redo any calculations/design affected. Updated drawings provided. Comment addressed. 3. Sheet S-1.0 General Notes: Under “Concrete”, change both references in note #3 from ACI 318-11 to ACI 318-14. Updated drawings provided. Comment addressed. 4. Sheet S2.0 First and Second Floor Plans: Provide Masonry, Foundation, and Lateral design calculations. Provided calculations from Western Wood Structures are only for wood superstructure members. Calculations drawings provided. Comment addressed. 5. Sheet S2.0 First and Second Floor Plans: Column size doesn’t match CLT drawings at column TC4 at grids F.8-9.8. Please clarify. Sheet 1 of the submitted wood framing shop drawings indicate a 6 ¾” x 26 1/8” column, but the column schedule on sheet S3.0 indicates a 6 ¾” x 21 ½” column. Please clarify. 6. Sheet S2.0 First and Second Floor Plans: Column size doesn’t match CLT drawings at all TC2 columns. Please clarify. Updated drawings provided. Comment addressed. 7. Sheet S2.0 First and Second Floor Plans: At grids C.2-7, a column is indicated on the CLT drawings but is not shown on this sheet. Please clarify. Sheet 1 of 5 of the wood framing shop drawings indicate a column, but sheet 2 and the details on sheets 4 and 5 do not indicate this column. It is understood based on the response that there is no wood column at C.2-7, and this comment is addressed. 8. Sheet S2.1 Roof Framing Plans: Provide Masonry and Lateral design calculations. Provided calculations from Western Wood Structures are only for wood superstructure members. Calculations drawings provided. Comment addressed. 03/15/2021 P a g e | 3 9. Sheet S4.0 Sections: At details 2, 3, and 18/S4.0, provide calculations indicating footings are structurally adequate due to the eccentric footing loads. Calculations provided. Comment addressed. 10. Sheet S4.0 Sections: At details 2, 3, and 18/S4.0, due to the thickness of the walls, two mats of reinforcement are required. Please revise details to conform to ACI 318-14 Chapter 11 requirements. Calculations provided. Comment addressed. Plan Review by: Andy Baturevich, P.E. HCDA Engineering, Inc. (719) 633-7784 Final Report Review and Local Contact: Thomas R. Thompson, CBO and ICC Certified Plans Examiner Sunrise Engineering 6875 South 900 East Salt Lake City, UT 84047 Cell (303) 328-1546 Office (435) 743-6151 E-mail tthompson@sunrise-eng.com 03/15/2021