Loading...
HomeMy WebLinkAboutInspection.533 W Hallam St.0285.2018 (4).ARBK04/20/2020 04/21/2020 justinh 03/24/2020 T TT 2 6 6 7 7 8 8 9 9 10 10 LL GG DD CC 3 4 E H 1 1 AA BB FAMILY / GAME 001 LAUNDRY 005 STO. 004 DRESS 021 BDRM #2 020 BATH #2 023 W.C. 025 BDRM #1 010 DRESS 011 CLO. 012 BATH #1 013 W.C. 014 W.C. 034 BATH #3 033 DRESS 031 CLO. 032 BDRM #3 030 BDRM #4 040 POWDER 002 BATH #4 042 W.C. 043 B15 - S 2 1/2"x12" B15 - S 2 1/2"x12" B195 - R 2 1/2"x36" B290 - R 2 1/2"x30" 2 1/2"x12"B 15 - S TO HP-1, ZD-1A & RZ-4A 10"x 26" (12"x28") DN 10"x 26" (12"x28") DN (2) 4" EA DN TO DRYER 8" EA DN(2) 4" CA & 4" VENT UP & DN B145 - S 2 1/2"x30" B105 - R 2 1/2"x24" B140 - S 2 1/2"x24" 2 1/2"x12"B 20 - S 20"x 8" (22"x10") 30"x 8" (32"x10") B55 - S 2 1/2"x12" B685 3"x78" B270 - S 3"x30"B270 - R 3"x30" 3"x30"B 200 - R B140 - S 2 1/2"x24" 2 1/2"x12"B 45 - S B15 - S 2 1/2"x12" 2 1/2"x30"B 195 - R2 1/2"x30"B 130 - S B105 - R 2 1/2"x24"B50 - S 2 1/2"x12"2 1/2"x12"B 50 - S B290 - R 2 1/2"x30" 14"x 10" (16"x12") UP 14"x 10" (16"x12") UP 2 1/2"x30"B 280 - S 14"x 6" (16"x8") UP 10 9 8 7 6 5 4 3 2 1 A C D E F G H J K L 1 1 1 1 1 TO HP-1, ZD-1C, & RZ-3B 1 1 1 1 1 1 1 11 1 1 1 1 TO HP-1, ZD-1B, & RZ-1A 3"x48"B 400 - S 285 -SA 400 -TA 400 -TA L 2 ww w . a e c - v a i l . c o m of Drawn By:Checked By: AEC PROJECT #: COPYRIGHT 2018 ARCHITECTURAL ENGINEERING CONSULTANTS, INC.c c ae PO B o x 8 4 8 9 , 4 0 8 0 1 U S H w y 6 & 2 4 , S t e 2 1 4 , A v o n , C o lo r a d o , 8 1 6 2 0 Me c h a n i c a l , E l e c t r i c a l & L i g h t i n g D e s i g n S e r v i c e s Ar c h i t e c t u r a l E n g i n e e r i n g C o n s u l t a n t s Te l e p h o n e : 9 7 0 - 7 4 8 - 8 5 2 0 F a x : 9 7 0 - 7 4 8 - 8 5 2 1 An O f f i c e w i t h L E E D ™ A c c r e d i t e d P r o f e s s i o n a l s DATE:ISSUE: FOR PERMIT ONLY SCALE 1/4" = 1'-0" 18032.00 DU N C A N S K I H A U S 53 3 W E S T H A L L A M AS P E N , C O L O R A D O , 8 1 6 1 1 M-111A LOWER LEVEL HVAC FLOOR PLAN 4 14 BLU TOC 11-23-18 PERMIT 1/4" = 1'-0"1 LOWER LEVEL HVAC FLOOR PLAN 1. ALL DUCTWORK DIMENSIONS ARE SHOWN INSIDE TO INSIDE. 2. ALL INTERIOR SUPPLY AND RETURN DUCTWORK SHALL INCLUDE 1" LINER UNLESS OTHERWISE NOTED. ALL OUTSIDE AIR INTAKE AND ROUND DUCTWORK SHALL BE WRAPPED WITH 1.5" THICK INSULATION UNLESS OTHERWISE NOTED. 3. ALL FINAL DUCTWORK CONNECTIONS TO SUPPLY GRILLES (OR PLENUMS) SHALL BE COMPLETED WITH ACOUSTICAL FLEXIBLE DUCT UNLESS OTHERWISE NOTED AND A MAXIMUM LENGTH OF FIVE FEET. 4. ALL ROUND DUCT CONNECTIONS TO ROUND DUCTWORK SHALL BE CONICAL TEES. 5. ALL SQUARE 90 DEGREE ELBOWS SHALL HAVE TURNING VANES. 6. ALL DUCTWORK SHALL BE RUN TIGHT TO UNDERSIDE OF STRUCTURE WHERE IT EXISTS UNLESS OTHERWISE NOTED. 7. ALL DUCTWORK PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL INCLUDE FIRE DAMPERS RATED TO MATCH THAT OF THE ASSEMBLY, EVEN WHERE NOT EXPLICITLY NOTED ON THIS PLAN. 8. ALL FIRE DAMPERS ARE INTENDED TO BE SPRING OPERATED CURTAIN DAMPERS. ALL FIRE SMOKE DAMPERS ARE INTENDED TO BE EQUIPPED WITH 120V ACTUATORS. 9. ALL SUPPLY GRILLES SHALL INCLUDE A BALANCING DAMPER(S), EVEN IF NOT SPECIFICALLY SHOWN, UNLESS OTHERWISE NOTED. IF THE DAMPER IS LOCATED IN AN INACCESSIBLE LOCATION, CABLE-STYLE DAMPERS (ROTOTWIST OR EQUIVALENT) SHALL BE INSTALLED AND SHALL BE ADJUSTABLE FROM THE GRILLE FACE. 10. COORDINATE ALL ACCESS PANEL LOCATIONS WITH THE ARCHITECT. 11. ALL MOTORIZED DAMPER ACTUATORS SHALL BE LOW VOLTAGE. IT IS MECHANICAL CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL NECESSARY EQUIPMENT AND WIRING FOR THEIR INSTALLATION. IF 120 V ACTUATORS ARE DESIRED, COORDINATE WITH ELECTRICAL CONTRACTOR OR CONTACT ELECTRICAL ENGINEER. 12. ALL DUCTWORK SHALL BE SUPPORTED IN ACCORDANCE WITH THE 2015 IMC 603.10 AND SMACNA HVAC DUCT CONSTRUCTION STANDARDS. GENERAL NOTES:SHEET NOTES: 1 LOCATE HIGH ON WALL. 09-16-19 PERMIT COMMENTS R1 12-16-19 PERMIT COMMENTS R2 12-20-19 PRICING SET 01-16-20 PERMIT COMMENTS R3 03-25-20 CD CEHCK SET 04-17-20 PERMIT COMMENTS R2.2 04/21/2020 justinh 04/20/2020 2 6 6 7 7 8 8 9 9 10 10 LL GG DD CC 3 4 E H 1 1 AA BB FAMILY / GAME 001 LAUNDRY 005 STO. 004 DRESS 021 BDRM #2 020 BATH #2 023 W.C. 025 BDRM #1 010 DRESS 011 CLO. 012 BATH #1 013 W.C. 034 BATH #3 033 DRESS 031 CLO. 032 BDRM #3 030 BDRM #4 040 POWDER 002 BATH #4 042 1 EF 2 EF 7 EF 8 EF 9 EF 6 EF 5 EF 4 EF 3 EF BDD BDD BDD BDD BDD BDD BDD BDD BDD 10"x 8" (12"x10")16"x 10" (18"x12") 16 " x 4 " ( 1 8 " x 6 " ) 8" x 8 " ( 1 0 " x 1 0 " ) 8" x 8 " ( 1 0 " x 1 0 " ) 8"ø8"ø 6"ø6"ø 8"ø8"ø8" ø 8" ø 8" ( 1 1 " ) 6"ø6"ø 8"ø8"ø 10 " x 8 " 10 " x 8 " 8" (11") 16"x 12" (18"x14") 16 " x 1 0 " ( 1 8 " x 1 2 " ) 8" x 8 " ( 1 0 " x 1 0 " ) 8" ø 8" ø 8"ø8"ø 8" x 6 " ( 1 0 " x 8 " ) 8"ø8"ø 6"ø6"ø 8" ø 8" ø 6"ø6"ø 16"x 10" (18"x12") 14 " x 8 " ( 1 6 " x 1 0 " ) 8" (11") 8" ø 8" ø 16"x 10" (18"x12") 6" ø 6" ø 8"ø8"ø 4" (7") 8" (11") 4" (7") 11"x 4" (12"x5") UP 13"x 4" (14"x5") UP 11"x 4" (12"x5") UP 11"x 4" (12"x5") UP 11"x 4" (12"x5") UP 11"x 4" (12"x5") UP 11"x 4" (12"x5") UP 13"x 4" (14"x5") UP 13"x 4" (14"x5") UP 2 1/2"x30" UP TO GRILLE 2 1/2"x36" UP TO GRILLE 2 1/2"x36" UP TO GRILLE2 1/2"x30" UP TO GRILLE 13"x 4" (14"x5") UP 8" (11") 13"x 4" (14"x5") UP 13"x 4" (14"x5") UP 13"x 4" (14"x5") UP 13"x 4" (14"x5") UP 13"x 4" (14"x5") 13"x 4" (14"x5") UP 13"x 4" (14"x5") UP 13"x 4" (14"x5") UP 13"x 4" (14"x5") UP 6"x12" UP 16 " x 1 0 " ( 1 8 " x 1 2 " ) 8"x4" UP (2) 4" CA & 4" VENT UP & DN 14"x 6" (16"x8") 6"x 6" (8"x8") 8" (11") 8" (11") 8" (11") 2 1/2"x18" UP TO GRILLE 2 1/2"x18" UP TO GRILLE 2 1/2"x18" UP TO GRILLE 2 1/2"x18" UP TO GRILLE 6" (9") 8" (11") 8" ( 1 1 " ) 8" (11") 12"x 8" (14"x10") 12 " x 1 2 " ( 1 4 " x 1 4 " ) 8" (11") 8" (11") 16 " x 1 2 " ( 1 8 " x 1 4 " ) 14"x 10" (16"x12") 12 " x 1 0 " ( 1 4 " x 1 2 " ) 20"x 8" (22"x10") DN 2 1/2"x24" UP TO GRILLE 2 1/2"x24" UP TO GRILLE 10 " ( 1 3 " ) 10"x 4" (11"x5") UP10"x 4" (11"x5") UP 10"x 4" (11"x5") UP 10"x 4" (11"x5") UP 2 1/2"x36" UP TO GRILLE 2 1/2"x36" UP TO GRILLE 10"x 4" (11"x5") UP 10"x 4" (11"x5") UP 8" (11") 8" (11") 30"x 8" (32"x10") DN 8" ( 1 1 " ) 18 " x 1 0 " ( 2 0 " x 1 2 " ) 12 " x 6 " 12 " x 6 " 18 " x 8 " ( 2 0 " x 1 0 " ) 18 " x 1 0 " ( 2 0 " x 1 2 " ) 18"x 8" (20"x10") DN 18"x 10" (20"x12") UP 18"x 8" (20"x10") UP 12"x6" UP 8" ( 1 1 " ) 8" ( 1 1 " ) 12 " x 6 " 12 " x 6 " 6" (9") 14"x 6" (16"x8") DN 14"x 10" (16"x12") 1 1 1 1 ww w . a e c - v a i l . c o m of Drawn By:Checked By: AEC PROJECT #: COPYRIGHT 2018 ARCHITECTURAL ENGINEERING CONSULTANTS, INC.c c ae PO B o x 8 4 8 9 , 4 0 8 0 1 U S H w y 6 & 2 4 , S t e 2 1 4 , A v o n , C o lo r a d o , 8 1 6 2 0 Me c h a n i c a l , E l e c t r i c a l & L i g h t i n g D e s i g n S e r v i c e s Ar c h i t e c t u r a l E n g i n e e r i n g C o n s u l t a n t s Te l e p h o n e : 9 7 0 - 7 4 8 - 8 5 2 0 F a x : 9 7 0 - 7 4 8 - 8 5 2 1 An O f f i c e w i t h L E E D ™ A c c r e d i t e d P r o f e s s i o n a l s DATE: ISSUE: FOR PERMIT ONLY SCALE 1/4" = 1'-0" 18032.00 DU N C A N S K I H A U S 53 3 W E S T H A L L A M AS P E N , C O L O R A D O , 8 1 6 1 1 M-111B LOWER LEVEL HVAC CEILING PLAN 5 14 BLU TOC 11-23-18 PERMIT 1/4" = 1'-0"1 LOWER LEVEL HVAC CEILING PLAN 1. ALL DUCTWORK DIMENSIONS ARE SHOWN INSIDE TO INSIDE. 2. ALL INTERIOR SUPPLY AND RETURN DUCTWORK SHALL INCLUDE 1" LINER UNLESS OTHERWISE NOTED. ALL OUTSIDE AIR INTAKE AND ROUND DUCTWORK SHALL BE WRAPPED WITH 1.5" THICK INSULATION UNLESS OTHERWISE NOTED. 3. ALL FINAL DUCTWORK CONNECTIONS TO SUPPLY GRILLES (OR PLENUMS) SHALL BE COMPLETED WITH ACOUSTICAL FLEXIBLE DUCT UNLESS OTHERWISE NOTED AND A MAXIMUM LENGTH OF FIVE FEET. 4. ALL ROUND DUCT CONNECTIONS TO ROUND DUCTWORK SHALL BE CONICAL TEES. 5. ALL SQUARE 90 DEGREE ELBOWS SHALL HAVE TURNING VANES. 6. ALL DUCTWORK SHALL BE RUN TIGHT TO UNDERSIDE OF STRUCTURE WHERE IT EXISTS UNLESS OTHERWISE NOTED. 7. ALL DUCTWORK PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL INCLUDE FIRE DAMPERS RATED TO MATCH THAT OF THE ASSEMBLY, EVEN WHERE NOT EXPLICITLY NOTED ON THIS PLAN. 8. ALL FIRE DAMPERS ARE INTENDED TO BE SPRING OPERATED CURTAIN DAMPERS. ALL FIRE SMOKE DAMPERS ARE INTENDED TO BE EQUIPPED WITH 120V ACTUATORS. 9. ALL SUPPLY GRILLES SHALL INCLUDE A BALANCING DAMPER(S), EVEN IF NOT SPECIFICALLY SHOWN, UNLESS OTHERWISE NOTED. IF THE DAMPER IS LOCATED IN AN INACCESSIBLE LOCATION, CABLE-STYLE DAMPERS (ROTOTWIST OR EQUIVALENT) SHALL BE INSTALLED AND SHALL BE ADJUSTABLE FROM THE GRILLE FACE. 10. COORDINATE ALL ACCESS PANEL LOCATIONS WITH THE ARCHITECT. 11. ALL MOTORIZED DAMPER ACTUATORS SHALL BE LOW VOLTAGE. IT IS MECHANICAL CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL NECESSARY EQUIPMENT AND WIRING FOR THEIR INSTALLATION. IF 120 V ACTUATORS ARE DESIRED, COORDINATE WITH ELECTRICAL CONTRACTOR OR CONTACT ELECTRICAL ENGINEER. 12. ALL DUCTWORK SHALL BE SUPPORTED IN ACCORDANCE WITH THE 2015 IMC 603.10 AND SMACNA HVAC DUCT CONSTRUCTION STANDARDS. GENERAL NOTES:SHEET NOTES: 1 COORDINATE ROUTING WITH STRUCTURE & ENSURE THAT DUCTS/FLUES STAY WITHIN CONDITIONED ENVELOPE. 09-16-19 PERMIT COMMENTS R1 12-16-19 PERMIT COMMENTS R2 12-20-19 PRICING SET 01-16-20 PERMIT COMMENTS R3 03-25-20 CD CEHCK SET 04-17-20 PERMIT COMMENTS R2.2 04/21/2020 justinh 04/20/2020 T T T T S S S 10 EF B35 - S 2 1/2"x12" 2 1/2"x14"B 130 - S B125 - S 2 1/2"x24" B100 - S 2 1/2"x18" B100 - S 2 1/2"x30" 2 1/2"x18"B 145 - R B445 - R 2 1/2"x48" B270 - S 2 1/2"x36"2 1/2"x36"B 270 - S B20 - S 2 1/2"x12" B230 - S 2 1/2"x24" B225 - S 2 1/2"x24" B365 - R 2 1/2"x48" B175 - S 2 1/2"x36"B175 - S 2 1/2"x36" B450 - R 2 1/2"x48"2 1/2"x48"B 450 - R B205 - S 2 1/2"x30" BDD 11 EF BDD 12 " x 6 " 12 " x 6 " 6"ø6"ø 8" x 4 " 8" x 4 " 14 " ø 14 " ø 4" ø 4" ø SEE SHEET NOTE 2 SEE SHEET NOTE 1 TO HP-2 & RZ-6A TO HP-3 & RZ-7A B295 - R 3"x30" B150 - R 2 1/2"x18" B75 - S 2 1/2"x18" B75 - S 2 1/2"x15" B190 - R 2 1/2"x24"B100 - S 2 1/2"x18" B100 - S 2 1/2"x18" B225 - R 2 1/2"x24" B230 - R 2 1/2"x24"B200 - S 2 1/2"x24" 18 " x 1 0 " ( 2 0 " x 1 2 " ) 18"x 10" (20"x12") 18"x 10" (20"x12")10"x 8" (12"x10") 14"x 8" (16"x10") 8"x 14" (10"x16") UP 8"x 10" (10"x12") UP 10"x 14" (12"x16") UP 6"x 12" (8"x14") UP DINING 113 ENTRY 111 CASUAL DINING 109 LIVING 106 KITCHEN 107 GARAGE 103 MUDROOM 102 ENTRY 101 POWDER 105 PANTRY 108 OFFICE 114 BAR 115 ENTRY HALL 110 L 1 L 3 L 4 12 " x 6 " 12 " x 6 " L 5 6"x12"6"x12" 2 1/2"x36"B 310 - S 2 1/2"x36"B 310 - S 18"x 10" (20"x12") DN 10 10 9 9 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1 A A C C D D E E F F G G H H J J K K L L ww w . a e c - v a i l . c o m of Drawn By:Checked By: AEC PROJECT #: COPYRIGHT 2018 ARCHITECTURAL ENGINEERING CONSULTANTS, INC.c c ae PO B o x 8 4 8 9 , 4 0 8 0 1 U S H w y 6 & 2 4 , S t e 2 1 4 , A v o n , C o lo r a d o , 8 1 6 2 0 Me c h a n i c a l , E l e c t r i c a l & L i g h t i n g D e s i g n S e r v i c e s Ar c h i t e c t u r a l E n g i n e e r i n g C o n s u l t a n t s Te l e p h o n e : 9 7 0 - 7 4 8 - 8 5 2 0 F a x : 9 7 0 - 7 4 8 - 8 5 2 1 An O f f i c e w i t h L E E D ™ A c c r e d i t e d P r o f e s s i o n a l s DATE: ISSUE: FOR PERMIT ONLY SCALE 1/4" = 1'-0" 18032.00 DU N C A N S K I H A U S 53 3 W E S T H A L L A M AS P E N , C O L O R A D O , 8 1 6 1 1 M-112 FIRST FLOOR HVAC PLAN 6 14 BLU TOC 11-23-18 PERMIT 1/4" = 1'-0"1 1ST FLOOR HVAC PLAN 1. ROUTE 4"⌀DRYER EXHAUST TO EXTERIOR. INSTALL PER MANUFACTURERS INSTRUCTIONS. SELEC TED DRYER MUST HAVE AN EQUIVALENT LENGTH ALLOWANCE THAT EXCEEDS THE ESIMTATED EQUIVALENT LENGTH CALCULATED BELOW: HORIZONTAL DISTANCE:5' VERTICAL DISTANCE:12' 90 DEGREE ELBOWS:(4)(5') = 20' MAX DEVELOPED LENGTH:37' THE EQUIVALENT LENGTH OF THE DRYER DUCT MUST BE IDENTIFIED ON A PERMANENT LABEL OR TAG WITHIN 6' OF THE EXHAUST CONNECTION PER IMC 504.8.5. 2. ROUTE BOILER FLUES FROM BOILERS TO TERMINATION PER MANUFACTURER'S INSTRUCTIONS. SLOPE VENT PIPES AT 1/4"/FOOT BACK TO THE BOILER FOR ALL HORIZONTAL RUNS. MAINTAIN 1" CLEARANCE TO COMBUSTIBLES. DO NOT EXCEED 100' MAXIMUM DEVELOPED LENGTH FOR ANY RUN. ESTIMATED LENGTHS AND ELBOWS FOR LONGEST RUN BOILER ARE SHOWN BELOW: B-1,2 VENT (CPVC):HORIZONTAL DISTANCE:15' VERTICAL DISTANCE: 30' 90 DEGREE ELBOWS:(3)(5') = 15' 45 DEGREE ELBOWS:(1)(2.5') = 2.5' MAX DEVELOPED LENGTH:67.5' B-1,2 CA (PVC):HORIZONTAL DISTANCE:15' VERTICAL DISTANCE: 30' 90 DEGREE ELBOWS:(3)(5') = 15' 45 DEGREE ELBOWS:(1)(2.5') = 2.5' MAX DEVELOPED LENGTH:67.5' FOLLOW ALL MANUFACTURER'S INSTRUCTIONS FOR BOILER VENTING MATERIALS. PROVIDE CPVC ROUTING FOR THE BOILER FLUES (PVC IS ACCEPTABLE FOR THE COMBUSTION AIR). PVC IS NOT ALLOWED FOR ANY BOILER FLUE ROUTINGS. 3. ROUTE WITHIN WARM SIDE OF INSULATION WITHIN FIRE RATED ENCLOSURE. 1. ALL DUCTWORK DIMENSIONS ARE SHOWN INSIDE TO INSIDE. 2. ALL INTERIOR SUPPLY AND RETURN DUCTWORK SHALL INCLUDE 1" LINER UNLESS OTHERWISE NOTED. ALL OUTSIDE AIR INTAKE AND ROUND DUCTWORK SHALL BE WRAPPED WITH 1.5" THICK INSULATION UNLESS OTHERWISE NOTED. 3. ALL FINAL DUCTWORK CONNECTIONS TO SUPPLY GRILLES (OR PLENUMS) SHALL BE COMPLETED WITH ACOUSTICAL FLEXIBLE DUCT UNLESS OTHERWISE NOTED AND A MAXIMUM LENGTH OF FIVE FEET. 4. ALL ROUND DUCT CONNECTIONS TO ROUND DUCTWORK SHALL BE CONICAL TEES. 5. ALL SQUARE 90 DEGREE ELBOWS SHALL HAVE TURNING VANES. 6. ALL DUCTWORK SHALL BE RUN TIGHT TO UNDERSIDE OF STRUCTURE WHERE IT EXISTS UNLESS OTHERWISE NOTED. 7. ALL DUCTWORK PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL INCLUDE FIRE DAMPERS RATED TO MATCH THAT OF THE ASSEMBLY, EVEN WHERE NOT EXPLICITLY NOTED ON THIS PLAN. 8. ALL FIRE DAMPERS ARE INTENDED TO BE SPRING OPERATED CURTAIN DAMPERS. ALL FIRE SMOKE DAMPERS ARE INTENDED TO BE EQUIPPED WITH 120V ACTUATORS. 9. ALL SUPPLY GRILLES SHALL INCLUDE A BALANCING DAMPER(S), EVEN IF NOT SPECIFICALLY SHOWN, UNLESS OTHERWISE NOTED. IF THE DAMPER IS LOCATED IN AN INACCESSIBLE LOCATION, CABLE-STYLE DAMPERS (ROTOTWIST OR EQUIVALENT) SHALL BE INSTALLED AND SHALL BE ADJUSTABLE FROM THE GRILLE FACE. 10. COORDINATE ALL ACCESS PANEL LOCATIONS WITH THE ARCHITECT. 11. ALL MOTORIZED DAMPER ACTUATORS SHALL BE LOW VOLTAGE. IT IS MECHANICAL CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL NECESSARY EQUIPMENT AND WIRING FOR THEIR INSTALLATION. IF 120 V ACTUATORS ARE DESIRED, COORDINATE WITH ELECTRICAL CONTRACTOR OR CONTACT ELECTRICAL ENGINEER. 12. ALL DUCTWORK SHALL BE SUPPORTED IN ACCORDANCE WITH THE 2015 IMC 603.10 AND SMACNA HVAC DUCT CONSTRUCTION STANDARDS. GENERAL NOTES:SHEET NOTES: 09-16-19 PERMIT COMMENTS R1 12-16-19 PERMIT COMMENTS R2 12-20-19 PRICING SET 01-16-20 PERMIT COMMENTS R3 03-25-20 CD CEHCK SET 04-17-20 PERMIT COMMENTS R2.2 04/21/2020 justinh 04/20/2020 S T T T T T T S S S 2 25 6 6 7 7 8 8 9 9 10 10 L L K K JJ FF GG DD CC 3 3 4 4 EE HH 1 1 AA BB 5B RZ 30 SQFT 7A RZ 425 SQFT 7B RZ 130 SQFT 6B RZ 20 SQFT 6A RZ 1035 SQFT5A RZ 495 SQFT GARAGE 103 MUDROOM 102 ENTRY 101 LIVING 106 STAIR 120 STAIR 49 POWDER 105 KITCHEN 107 CASUAL DINING 109 ENTRY HALL 110 ENTRY 111 DINING 113 OFFICE 114 BIKES 104 1-A SZ 517.19 SQFT 7-A SZ 44.75 2-A SZ 164.27 SQFT3-A SZ 15.33 SQFT 3 SM 2 3 1 4 5 6TO HP-2 & RZ-6A TO HP-3 & RZ-7A TO RZ-7B TO RZ-5B TO RZ-5A TO RZ-6B 9 RM 1/2"ø HWS 1/2"ø HWR 3/4"ø HWS 3/4"ø HWR 7 RM 8 RM 6 2-B SZ 31.81 SQFT 2-C SZ 51.44 SQFT 4-A SZ 10.49 SQFT 1-B SZ 152.68 5A RZ 495 SQFT 1"ø HWS DN 1"ø HWR DN 7 SM7 ww w . a e c - v a i l . c o m of Drawn By:Checked By: AEC PROJECT #: COPYRIGHT 2018 ARCHITECTURAL ENGINEERING CONSULTANTS, INC.c c ae PO B o x 8 4 8 9 , 4 0 8 0 1 U S H w y 6 & 2 4 , S t e 2 1 4 , A v o n , C o lo r a d o , 8 1 6 2 0 Me c h a n i c a l , E l e c t r i c a l & L i g h t i n g D e s i g n S e r v i c e s Ar c h i t e c t u r a l E n g i n e e r i n g C o n s u l t a n t s Te l e p h o n e : 9 7 0 - 7 4 8 - 8 5 2 0 F a x : 9 7 0 - 7 4 8 - 8 5 2 1 An O f f i c e w i t h L E E D ™ A c c r e d i t e d P r o f e s s i o n a l s DATE:ISSUE: FOR PERMIT ONLY SCALE 1/4" = 1'-0" 18032.00 DU N C A N S K I H A U S 53 3 W E S T H A L L A M AS P E N , C O L O R A D O , 8 1 6 1 1 M-122 FIRST FLOOR MECHANICAL PIPING 10 14 BLU TOC 11-23-18 PERMIT 1/4" = 1'-0"1 MECHANICAL PIPING - 1ST FLOOR SHEET NOTES: 1 CONNECT 1/2" SMS/R TO SM-3. 2 CONNECT 1/2" HWS/R TO RM-9. 3 CONNECT 3/4" HWS/R TO RM-8. 4 CONNECT 3/4" HWS/R TO RM-7. 5 INSTALL SNOW & ICE SENSOR IN THE SNOWMELT ZONE AS SHOWN. COORDINATE EXACT LOCATION WITH G.C. ENSURE THE SENSOR IS EQUIDISTANT BETWEEN TUBING & NOT UNDER OVERHANGS OR IN WIND EDDIES. 6 SEE ARCH SITE PLAN FOR CONTINUATION 7 LOCATE SM-7 IN LANDSCAPING BOX. COORDINATE WITH ARCHITECT. 1. OFFSET PIPING AS REQUIRED TO AVOID ALL DUCTWORK, LIGHTS, AND STRUCTURE. COORDINATE ALL STRUCTURAL PENETRATIONS WITH THE STRUCTURAL ENGINEER. 2. ALL PIPING PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL INCLUDE A FIRE- RATED PIPE SEALANT RATED TO MATCH THAT OF THE ASSEMBLY. 3. VERIFY FINAL LOCATIONS OF ALL MANIFOLDS WITH THE G.C. CONTACT ENGINEER IF MANIFOLDS MOVE MORE THAN 10' FROM LOCATIONS SHOWN ON PLANS. 4. LOCATION OF ALL THERMOSTATS AND FLOOR SENSORS ARE APPROXIMATE, COORDINATE EXACT LOCATIONS WITH THE ARCHITECT. LOCATE FLOOR SENSORS EQUIDISTANT BETWEEN RADIANT LOOPS, AND DO NOT LOCATE WHERE THEY MAY LIKELY BE COVERED BY FUTURE RUGS OR FURNITURE. 5. ALL PIPING SIZED FOR TYPE L COPPER. CONTACT ENGINEER FOR ANY CHANGE TO PEX FOR NECESSARY PIPE SIZING AND/OR PUMP CHANGES. 6. INSULATE ALL PIPE LEADERS PASSING THROUGH ADJACENT ZONES. GENERAL NOTES: 09-16-19 PERMIT COMMENTS R1 12-16-19 PERMIT COMMENTS R2 12-20-19 PRICING SET 01-16-20 PERMIT COMMENTS R3 03-25-20 CD CEHCK SET 04-17-20 PERMIT COMMENTS R2.2 04/21/2020 justinh 04/21/2020 04/20/2020 04/21/2020 justinh 04/20/2020