HomeMy WebLinkAboutInspection.533 W Hallam St.0285.2018 (8).ARBKSTRUCTURAL STEEL GENERAL: 1. All structural steel work shall conform to AISC 360 and tolerances shall conform to AISC 303 unless noted otherwise. Contractor shall keep a copy of these references on site at all times. 2. Materials – See Steel Materials Table 3. Qualifications - Fabricator and Erector shall be experienced in fabrication and erection of projects of similar size and complexity. TESTING: 1. Tests and inspections shall be performed in compliance with AISC 360 and Chapter 17 of the IBC. Inspections include: Welding, high strength bolting, anchor rod placement, proper use of joint details, fabricated steel, and erected steel frame. Testing includes: UT of full penetration welds, bolt tensioning procedures, shear stud bend tests. SUBMITTALS: 1. Submittals shall conform to AISC 360. 2. Submittals for structural steel shall include erection drawings, shop drawings, and mill test reports. 3. Erection drawings shall include plan drawings at 1/8"=1'-0” minimum scale complete with sections, elevations, and details as required to properly erect the structural steel frame. 4. Shop drawings shall include piece drawings which indicate cuts, connections, camber, holes, welds and dimensions as required for fabrication of the members. Part drawings are not required to be submitted unless specifically requested. CONNECTIONS: 1. Engineer of Record (EOR) has designed all connections. If a connection design is inadvertently omitted from contract documents the contractor shall request specific connection design from the EOR. 2. Connection Design Forces: Unfactored ASD values. 3. Simple Beam Connections: Select connections with capacities equal to or greater than beam reactions shown on the drawings. Single sided connections shall be detailed to use the maximum number of bolt rows that can fit into the supported beam web. Double sided connections shall be detailed such that the angle or bent plate length is at least 60% of the supported beam "T" dimension. 4. HSS Cap Plates: Provide 1/4" cap plates at top of all HSS columns, uno. BOLTS: 1. Where indicated on the drawings as slip critical and where oversized or long-slotted holes are utilized in shear, bolted joints shall be slip critical. Faying surfaces shall be prepared to meet the requirements of a Class A surface, and bolts shall be installed to the fully tensioned condition. 2. Where bolts are subject to non-static loading, are utilized to interconnect parts of a built up compression member, or all Group B fasteners loaded in tension shall be installed to the fully tensioned condition. 3. Bolts not subject to the requirements for slip critical connections and not required to be fully tensioned may be installed to the snug-tight condition. 4. A307 bolts may be used only where indicated. WELDS: 1. Fillet Welds: Size as indicated, but not less than AISC minimum size. 2. Groove Welds: Full penetration unless noted otherwise. 3. Welds are continuous unless noted otherwise. ACCESSORIES: 1. Headed Stud Anchors: Shop weld except where applied through metal deck or where shop installation would result in a tripping hazard. SHOP CLEANING AND PAINTING: 1. Uncoated Steel: All steel not specifically indicated as painted, steel to receive spray-on-fireproofing or to be galvanized, and faying surfaces of slip critical connections shall be uncoated. Prepare surface per SSPC-SP1. 2. Primed Steel: Steel indicated to painted, with no specific paint requirements stated, shall have the surface prepared per SSPC-SP2 minimum and receive one coat of fabricator's standard rust-inhibitive primer paint applied to a minimum dry-film thickness of 1 mil. 3. Galvanized Steel: Steel indicated to be galvanized shall be cleaned, prepared, and galvanized in accordance with ASTM A123. Repair minor defects, damaged areas, and welded joints in accordance with ASTM A780. 4. Other specified coatings: Where indicated on the drawings, provide specified coating system as indicated. Clean and prepare steel as required by the specification or coating manufacture. ERECTION: 1. No final bolting or welding shall be performed until as much of the structure which will be stiffened thereby has been properly aligned. 2. Field correction of fabrication or other errors will be permitted only when approved by the EOR. Finish gas-cut sections in accordance with AWS D1.1. Standard 3/4"ø A325 Bolt BOLT GRADES Bolt Size, Joint Type and Designation on Drawings 3/4"ø Bolt, ASTM A325-N or ASTM F1852 3/4"ø A325 SC-A Bolt3/4"ø Bolt, ASTM A325 or ASTM F1852 with Class A Faying Surface NOTES: 1. Reference plan, details and connection tables for bolt size and joint type. 2. All bolts are snug tight, unless indicated on plan or details as slip critical or fully tensioned. 3. Where bolts are indicated as slip critical or fully tensioned, pretension bolt as defined by AISC 360, Table J.1 4. Class A faying surfaces are unprimed surfaces or hot dip galvanized surfaces with hand wire brush roughening, as defined by AISC 360. 5. Class B faying surfaces are blast cleaned surfaces as defined by AISC 360. 1"ø A490 Bolt1"ø Bolt, ASTM A490-N or ASTM F2280 1"ø Bolt, ASTM A490 or ASTM F2280 with Class A Faying Surface 1/2"ø or 3/4"ø A307 Bolt1/2"ø or 3/4"ø Bolt, ASTM A307 Gr. A 1"ø A490 SC-A Bolt W and WT Sections Material Standard ASTM A992 (50 ksi) or ASTM A572 Gr. 50 (50 ksi) STEEL MATERIALS DESIGNATION ASTM A36 (36ksi)M, S, C, MC, L, MT, ST Sections ASTM A572 Gr. 50 (50ksi)HP Sections ASTM A53 Gr. B (35ksi)Pipe ASTM A500 Gr. B (46 ksi)Rectangular HSS Round HSS Plates, Bars, and threaded rod - typical - when noted as 50ksi ASTM F1554 Gr. 55 w/ Supplement S1Anchor Rods ASTM A325 or ASTM F1852 ASTM A490 or ASTM F2280 ASTM A307 Gr. A Bolts - typical (Group A) - where noted as Group B - where indicated as A307 ASTM A563, Heavy HexNuts ASTM A500 Gr. B (42 ksi) ASTM A36 (36ksi) ASTM A572 Gr. 50 (50ksi) ASTM F436, except plate washers to be ASTM A36 Washers ASTM F959Direct-Tension-Indicator Washers ASTM A108Headed Stud Anchors E70, 70ksiWeld Electrodes STEEL DECKING GENERAL: 1. Non-composite steel floor deck shall conform to SDI-NC1.0. 2. Composite steel floor deck shall conform to SDI-C1.0. 3. Steel roof deck shall conform to SDI-RD1.0. 4. Qualifications - Deck Manufacture shall be a member of the Steel Deck Institute. TESTING: 1. Tests and inspections shall be performed in compliance with AISC 360 and Chapter 17 of the IBC. Inspections include: Welding, proper use of joint details. 2. See "Special Inspections and Testing" Table. SUBMITTALS: 1. Submittals for steel deck shall include deck placement drawings. 2. Deck placement drawings shall include plan drawings at 1/8"=1'-0” minimum scale complete with details as required to properly erect the steel deck. DECK MATERIALS: 1. Steel for Deck: minimum yield strength of 33ksi. 2. Provide all required accessories including cell closures, pour stops, ridge, and valley plates. DECK ATTACHMENTS: 1. Weld Electrodes: E60, 60ksi unless noted otherwise. Low hydrogen electrodes not required. 2. Self-drilling self-tapping screws (Tek screws): size as indicated, zinc plated per ASTM F1941, minimum zinc thickness = 5 microns. 3. Low-velocity fasteners (shot pins): 0.145" (minimum) diameter hardened pins. 4. For composite decks, headed stud anchors may replace welds for deck attachment. 5. See plan notes and typical details for required deck attachment type and pattern. NON-COMPOSITE STEEL FLOOR DECK: 1. Deck indicated is designed to not require shoring. Manufacture to verify supplied deck works for unshored construction. 2. Formed Openings Through Deck: see typical details for requirements at deck openings. Deck to remain in place until opening is required. Trade requiring opening is responsible for cutting opening. 3. See architectural drawings for fire rating requirements. Provide deck stamped with appropriate UL label when required. STEEL ROOF DECK: 1. Do not suspend point loads in excess of 20 pounds from deck. Attachments shall be spaced 8 feet apart or more, and within 2 feet of member supporting roof deck. Provide sub-framing as required for heavier point loads. 2. Formed Openings Through Deck: See typical details for requirements at deck openings. Deck to remain in place until opening is required. Trade requiring opening is responsible for cutting opening. 3. See architectural drawings for fire rating requirements. Provide deck stamped with appropriate UL label when required. WOOD FRAMING GENERAL: 1. All wood construction work shall conform to ANSI/AF&PA NDS unless noted otherwise. Contractor shall keep a copy of these references on site at all times. 2. Materials – See Wood Materials Tables 3. Qualifications – Carpenter shall be experienced in construction of projects of similar size and complexity and shall be knowledgeable of conventional light frame construction practices and minimum nailing requirements of the IBC. PRODUCTS: 1. All wood framing shall be at a moisture content of 19% or less and shall be marked S-Dry (surface dried) or KD (kiln dried). 2. Unless noted otherwise, all sizes noted on these drawings are nominal. Actual sizes are based on "Minimum Dressed-Dry" dimensions according to American Softwood and Lumber Standard PS20-10. 3. Unless noted otherwise, all manufactured framing sizes are based on specified manufacturers published information. 4. Wall studs to be Douglas Fir-Larch (DFL) stud grade or Laminated Strand Lumber (LSL)@16"OC, unless noted otherwise in the drawings. 5. Wood I-joists: where framing members are noted TJI on the drawings, use engineered products by Weyerhaeuser or approved equal. 6. Structural Panels: Sheathing for roofs and walls shall conform to APA PS-2 standards. All panels shall be Exposure 1, unless noted otherwise. Provide pressure treated sheathing products within 6" of grade at exterior locations, see architectural drawings for locations. 7. Sills: Sill plates shall be pressure treated Douglas Fir-Larch stamped to show compliance with AWPA standards. HEAVY TIMBER FRAMING: 1. General: sound, thoroughly seasoned, and free of warp or significant surface defects. 2. Material: see table and plans for species and grade. 3. For large members (12" nominal or greater maximum dimension), box heart members may be used. For smaller members, free of heart center timbers may be used. Do not use timber with excessive reaction or juvenile wood. 4. Moisture Content: Provide timber with 15% average moisture content at time of dressing. Use a nominal 10x10 timber for determining baseline average moisture content throughout the cross section. Variation in moisture content from the center to the edge of the timber shall not exceed 8%. 5. End Sealer: Manufacturer's standard, transparent, colorless wood sealer effective in retarding transmission of moisture at cross-grain cuts and compatible with finish. 6. Exposed framing shall be appearance grade; reference architectural drawings for finish requirements. CONNECTORS: 1. All bolts, metal connectors, hangers, anchors, and fasteners in contact with preservative treated wood shall be hot dipped galvanized G90 or stainless steel type 304 or 316. 2. Provide 5/8" diameter anchor bolts @48"OC at the top of all foundation elements for attaching sill plates, except at shear walls. See Shear Wall Nailing Schedule for shear wall anchor bolt spacing. As a minimum, provide two bolts, each within 12" of the ends of each piece of sill plate. 3. J and L type bolts are allowed for anchorage of wood sills. 4. Anchor bolts shall be cast into concrete or grouted into masonry with a minimum embedment of 7". 5. Provide plate washers at all shear wall anchor bolt connections to wall plates. See "Typical Wood Shear Walls - Nailing Schedule and Details" for more information. 6. Nailing shall conform to the minimum requirements contained in Table 2304.9.1 of the IBC unless more stringent requirements are shown on these drawings or in these notes. 7. All nails are to be steel common wire nails and conform to ASTM F1667. 8. Pre-drill nail holes when necessary to prevent splitting. 9. Steel plates for wood construction shall conform to ASTM A36. 10. Bolts shall conform to ASTM A307. 11. All exposed bolts in wood structure which are not in contact with preservative treated wood shall be plain, uncoated steel. 12. Holes for bolts shall be 1/16" oversized. 13. Retighten all bolts prior to closing in. 14. Lag screws shall penetrate the main member a minimum of eight times the shaft diameter unless noted otherwise. 15. Diagonal (toe-nail) lag screws shall be installed with a minimum edge distance of four times the shaft diameter. WOOD FRAMING (continued) INSTALLATION: 1. Built-up Columns: Where hidden in a wall, at contractor's option, wood columns may be built-up from 2x laminations. Laminations shall be stitched nailed with staggered 16d@4"OC. Do not splice laminations. 2. Truss rods and connections shall be tightened after installation and leveling. 3. At roofs and floors, lay panels with long dimension perpendicular to supports with short edges staggered. 4. Glue and nail floor sheathing to supports with 8d@6"OC edges and 8d@ 12"OC field. 5. Nail roof sheathing to supports with 8d@6"OC edges and 8d@12"OC field. 6. See plans for areas of special blocking and nailing. 7. Nail vertical sheathing to supports with 8d@6"OC edges and 8d@12"OC field for walls not designated as shear walls. 8. Where shear walls are noted on the plans, the sheathing is used as part of the lateral load resisting system. See typical details for attachment of sheathing to supports for wood structural panel shear walls. 9. All panel edges within the extent of the shear wall shall be blocked with flat 2x4 blocking. FRAMING TOLERANCES: 1. Layout of walls and partitions: within 1/4" of intended position. 2. Plates and runners: 1/4" in 8' from a straight line. 3. Studs: 1/4" in 8' out of plumb, not cumulative. 4. Face of framing: 1/4" in 8' from a true plane. COMMON NAIL DIMENSIONS Minimum Length (in)Common Nail (Steel Wire)Minimum Diameter (in) 0.113 2 0.131 2 1/2 0.148 3 0.148 3 1/4 0.162 3 1/2 0.192 4 6d 8d 10d 12d 16d 20d DOUGLAS FIR-LARCH (DFL) Select Structural 1,500 psi 1,700 psi 180 psi 1,900 ksi No1 1,000 psi 1,500 psi 180 psi 1,700 ksi No2 900 psi 1,350 psi 180 psi 1,600 ksi Flexural Stress DESIGN VALUES FOR DIMENSIONAL LUMBER Compressive Stress Horizontal Shear Stress Modulus of Elasticity Species & Grade Flexural Stress DESIGN VALUES FOR MANUFACTURED LUMBER LAMINATED STRAND LUMBER (LSL) 2x4 and 2x6 Studs - 1.3E Compressive Stress Horiz Shear Stress Modulus of Elasticity 1,700 psi 1,400 psi 400 psi 1,300 ksi 2,250 psi 1,950 psi 400 psi 1,500 ksi 2,600 psi 2,510 psi 285 psi 2,000 ksi Type - E Compressive Stress Perp 435 psi 475 psi 750 psi Tensile Stress 1,075 psi 1,500 psi 1,555 psi LAMINATED VENEER LUMBER (LVL) 2x8 Studs - 1.5E Headers and Beams - 2.0E WOOD STRUCTURAL PANEL REQUIREMENTS Roof over Trusses/Rafters Minimum ThicknessSupporting Element APA Span Rating 48/24 23/32" Floors (Sturd-I T&G)24 OC Single Floor 23/32" Walls 32/16 15/32" Shear Walls 32/16 15/32" KL A& Engineers Builders 215 North 12th Street, Unit E Carbondale, Colorado 81623 P: (970) 927 5174 F: (970) 927 5194 Buffalo, WY ○ Carbondale, CO ○ Golden, CO ○ Loveland, CO & Consultant ARCHITECTURE PLANNING+ ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T, A S P E N, C O L O R A D O 8 1 6 1 1 SHEET TITLE K L&A, IN Cc2019 PROJECT NO: Issue: TH E S T R U C T U R A L E N G I N E E R S S E A L O N T H I S D R A W I N G I N D I C A TE S T H A T T H E I N F O R M A T I O N S H O W N A N D T H E CA L C U L A T I O N S P E R T A I N I N G T O T H A T I N F O R M A T I O N H A V E B E EN P R E P A R E D B Y Q U A L I F I E D P E O P L E U N D E R T H E DI R E C T I O N O F T H E E N G I N E E R - O F - R E C O R D . T H E S E A L D O E S NO T I M P L Y R E S P O N S I B I L I T Y F O R I N F O R M A T I O N P R E P A R E D BY O T H E R S N O R F O R A N Y I N F O R M A T I O N N O T S H O W N O N T H I S DR A W I N G A N D S U C H R E S P O N S I B I L I T Y I S S P E C I F I C A L L Y DI S C L A I M E D . O N P H A S E D P R O J E C T S , D R A W I N G S T H A T A R E I S S UE D B U T N O T S E A L E D S H A L L B E C O N S I D E R E D T O B E PR E L I M I N A R Y I N N A T U R E A N D A R E I S S U E D F O R I N F O R M A T I O N O N L Y . TH E S E D R A W I N G S A R E T O B E U S E D I N CO N J U N C T I O N W I T H T H E A R C H I T E C T U R A L DR A W I N G S O N T H E P R O J E C T T O C L E A R L Y DE F I N E A L L O F T H E R E Q U I R E M E N T S F O R T H E CO N S T R U C T I O N . W H E R E C O N F L I C T S O C C U R CO N T A C T A R C H I T E C T F O R C L A R I F I C A T I O N . 4/ 3 / 2 0 2 0 1 1 : 4 9 : 3 1 A M DUNCAN RESIDENCE 533 W HALLAM ST ASPEN, CO 81611 S103 GENERAL NOTES B0567 10/31/18 PERMIT 06/20/19 PERMIT COMMENTS RESPONSE 04/03/2020 04/20/2020 04/21/2020 justinh FLOW FILL AT LIGHT WELL MAT FOOTING 1'-0" T/SOG T/FTG T/SHEATHING T/WALL T/FTG T/SOG CONC FDN WALL, #4 DWL TO MATCH VERT WALL REINF SPACING, TYP CONC MAT FTG, REINF W/ #5@12"OC EW BOT CONC FDN WALL, REINF W/ #6@18"OC EW EF, CENTER INSIDE MAT IN STEM FLOOR FINISHES, RE: ARCH WOOD SHEATHING W/ CONC STRUCT TOPPING SLAB, RE: PLAN FOR THK & REINF WOOD FRAMING W/ SIMPSON HANGER, RE: PLAN & HANGER SCHED TYP CONC SOG, RE: PLAN FOR THK & REINF CONC FTG, RE: PLAN & FTG SCHED NON-COMPRESSIBLE EXPANSION JOINT MATERIAL, TYP PT 2x SILL PLATE W/ ANCHOR BOLT, RE: GEN NOTES RE: 1/S401 LIGHT WELL SOG, RE: PLAN FOR THK & REINF CONC FDN WALL, REINF W/ #6@18"OC EW CENTERED T/LEDGE RE: PLAN RE: PLAN RE: PLANRE: PLAN 2" CLR GRID T/SLAB T/SOG T/FTG T/SHEATHING T/WALL T/FTG T/SOG GRID CONC FDN WALL, REINF W/ #6@9"OC VERT & #6@18"OC HORIZ CENTERED #6 DWL TO MATCH VERT WALL REINF SPACING, TYP CONC FTG, RE: PLAN & FTG SCHED CONC FDN WALL, REINF W/ #6@18"OC EW CENTERED RE: PLAN FLOOR FINISHES, RE: ARCH WOOD SHEATHING W/ CONC STRUCT TOPPING SLAB, RE: PLAN FOR THK & REINF WOOD FRAMING W/ SIMPSON HANGER, RE: PLAN & HANGER SCHED TYP CONC SOG, RE: PLAN FOR THK & REINF CONC FTG, RE: PLAN & FTG SCHED NON-COMPRESSIBLE EXPANSION JOINT MATERIAL, TYP PT 2x SILL PLATE W/ ANCHOR BOLT, RE: GEN NOTES NOTE: FLOOR FRAMING MAY SPAN OPP DIRECTION DOUBLE 11 7/8" LVL LEDGER, ATTACH TO FDN WALL W/ 5/8"/x8" TITEN HD SCREW ANCHOR@16"OC STAGGERED T/SLAB RE: PLAN AT SIM, THICKER EXT FDN WALL STUD PACK BEYOND AT LVL BEAM, RE: PLAN, FASTEN TO CONC WALL W/ (4)5/8"/x8" TITEN HD SCREW ANCHORS, EQUALLY SPACED MOISTURE BARRIER MOISTURE BARRIER T/WALL CONC FDN WALL, EXT HARDSCAPING, RE: ARCH STRUCT SLAB, RE: PLAN FOR THK & REINF L3x3x1/4xCONT W/ 1/2"/x4" HSA@36"OC T/STL T/SHEATHING T/STEM WALL RE: 1/S401 FINISHES, RE: ARCH WOOD STUD WALL, RE: PLAN WOOD FRAMING, RE: PLAN WF BM, RE: PLAN 5/8"/ THREADED ROD@16"OC #4 HORIZ AT SIM, DECK AND WOOD FRAMING SPAN OPP DIRECTION GRID 2x PT SILL PLATE T/SLAB DECK ATTACHMENT, RE: PLAN #4 DOWEL@18"OC PT SHEATHING AT BASE OF WALL, RE: ARCH, PROVIDE BLOCKING FOR PANEL EDGE NAILING, RE: TYP DETAILS 10 T/WALL CONC FDN WALL, RE: 1/S401 GARAGE DOOR, RE: ARCH STRUCT SLAB, RE: PLAN FOR THK & REINF L3x3x1/4xCONT W/ 1/2"/x4" HSA@36"OC NOTE: NO DOOR AT SIM #4 DOWEL@18"OC TOPPING SLAB OR FINISHES, RE: ARCH, RE: PLAN FOR SLAB REINF T/SLAB T/STL T/SHEATHING WOOD FRAMING W/ SIMPSON HANGER, RE: PLAN & HANGER SCHED FINISHES, RE: ARCH WF BM, RE: PLAN EXT HARDSCAPING, RE: ARCH STRUCT SLAB, RE: PLAN FOR THK & REINF L4x4x1/4xCONT AT EXT CONDITION ONLY W/ 1/2"/x4" HSA@36"OC 1/4 2-12 1/4 2-12VERT LEG T/SLAB 2x PT SILL PLATE AT SIM, DECK & JOISTS SPAN OPP DIRECTION J L4x4x1/4xCONT, NO HSA AT THIS LOCATION RE: 4/S401 T/SLAB WF BM, RE: PLAN EXT HARDSCAPING, RE: ARCH STRUCT SLAB, RE: PLAN FOR THK & REINF T/SLAB WOOD STUD WALL, RE: PLAN #4 HORIZ STRUCT SLAB, RE: PLAN FOR THK & REINF 5/8"/ THREADED ROD@16"OC T/STEM WALL TOPPING SLAB, RE: ARCH3" MIN #4 CONT DECK ATTACHMENT, RE: PLAN 2x PT SILL PLATE PT SHEATHING AT BASE OF WALL, RE: ARCH F T/SLAB WF BM, RE: PLAN & TYP DETAIL FOR PACK OUT REQUIREMENTS WOOD STUD WALL, RE: PLAN #4 HORIZ STRUCT SLAB, RE: PLAN FOR THK & REINF 5/8"/ THREADED ROD@16"OC T/SHEATHING WOOD FRAMING W/ SIMPSON HANGER, RE: PLAN & HANGER SCHED DOUBLE LVL LEDGER, ATTACH TO SLAB W/ 5/8"/x8" TITEN HD SCREW ANCHOR@16"OC, ATTACH TO PACK OUT W/ (2)10d NAILS@8"OC FINISHES, RE: ARCH T/STEM WALL 2x PT SILL PLATE 3 1/2" AT SIM, DECK SPANS OPP DIRECTION GRID SLOPED TOPPING SLAB, RE: ARCH NOTE: WHERE WOOD FRAMING SPANS OPP DIRECTION, PROVIDE BLOCKING, RE: DETAILS DECK ATTACHMENT, RE: PLAN KL A& Engineers Builders 215 North 12th Street, Unit E Carbondale, Colorado 81623 P: (970) 927 5174 F: (970) 927 5194 Buffalo, WY ○ Carbondale, CO ○ Golden, CO ○ Loveland, CO & Consultant ARCHITECTURE PLANNING+ ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T, A S P E N, C O L O R A D O 8 1 6 1 1 SHEET TITLE K L&A, IN Cc2019 PROJECT NO: Issue: SCALE: TH E S T R U C T U R A L E N G I N E E R S S E A L O N T H I S D R A W I N G I N D I C A TE S T H A T T H E I N F O R M A T I O N S H O W N A N D T H E CA L C U L A T I O N S P E R T A I N I N G T O T H A T I N F O R M A T I O N H A V E B E EN P R E P A R E D B Y Q U A L I F I E D P E O P L E U N D E R T H E DI R E C T I O N O F T H E E N G I N E E R - O F - R E C O R D . T H E S E A L D O E S NO T I M P L Y R E S P O N S I B I L I T Y F O R I N F O R M A T I O N P R E P A R E D BY O T H E R S N O R F O R A N Y I N F O R M A T I O N N O T S H O W N O N T H I S DR A W I N G A N D S U C H R E S P O N S I B I L I T Y I S S P E C I F I C A L L Y DI S C L A I M E D . O N P H A S E D P R O J E C T S , D R A W I N G S T H A T A R E I S S UE D B U T N O T S E A L E D S H A L L B E C O N S I D E R E D T O B E PR E L I M I N A R Y I N N A T U R E A N D A R E I S S U E D F O R I N F O R M A T I O N O N L Y . TH E S E D R A W I N G S A R E T O B E U S E D I N CO N J U N C T I O N W I T H T H E A R C H I T E C T U R A L DR A W I N G S O N T H E P R O J E C T T O C L E A R L Y DE F I N E A L L O F T H E R E Q U I R E M E N T S F O R T H E CO N S T R U C T I O N . W H E R E C O N F L I C T S O C C U R CO N T A C T A R C H I T E C T F O R C L A R I F I C A T I O N . 4/ 3 / 2 0 2 0 1 1 : 4 9 : 3 1 A M DUNCAN RESIDENCE 533 W HALLAM ST ASPEN, CO 81611 S401 DETAILS B0567 3/4" = 1'-0"2 SECTION AT LIGHT WELL 3/4" = 1'-0"1 SECTION AT BASEMENT FOUNDATION 1" = 1'-0"3 SECTION AT STRUCTURAL SLAB 1" = 1'-0"5 SECTION AT GARAGE THRESHOLD 1" = 1'-0"4 SECTION AT STRUCTURAL SLAB 1" = 1'-0"6 SECTION AT GARAGE 1" = 1'-0"7 SECTION AT GARAGE/MUDROOM MOISTURE BARRIER 10/31/18 PERMIT 06/20/19 PERMIT COMMENTS RESPONSE 04/03/2020 04/20/2020 04/21/2020 justinh