Loading...
HomeMy WebLinkAboutFile Documents.430 W Hallam St.0291.2017 (34).ARBKREScheck Software Version 4.7.1 Compliance Certificate Project 17052.00 430 W Hallam Residence Energy Code:2015 IECC Location:Aspen, Colorado Construction Type:Single-family Project Type:New Construction Conditioned Floor Area:7,650 ft2 Glazing Area 20% Climate Zone:7 (9922 HDD) Permit Date: Construction Site: 430 W Hallam St Aspen, CO 81611 Owner/Agent: 430 HALLAM LLC Designer/Contractor: KARA THOMPSON FORUM PHI ARCHITECTURE 914-494-8698 KTHOMPSON@FORUMPHI.COM Permit Number: Compliance: Passes using UA trade-off 4.9% Better Than Code Maximum UA:1235 Your UA:1175 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance: Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Basement Wall 1: Solid Concrete or Masonry Wall height: 12.0' Depth below grade: 12.0' Insulation depth: 12.0' 2,808 12.5 10.0 0.031 85 Window 2: Metal Frame:Double Pane with Low-E 76 0.300 23 Wall 1: Wood Frame, 16" o.c.5,962 20.0 5.0 0.044 199 Window 1: Metal Frame:Double Pane with Low-E 8 0.240 2 Window 2: Metal Frame:Double Pane with Low-E 71 0.280 20 Window 3: Metal Frame:Double Pane with Low-E 358 0.290 104 Window 4: Metal Frame:Double Pane with Low-E 702 0.300 211 Window 5: Metal Frame:Double Pane with Low-E 14 0.310 4 Window 6: Metal Frame:Double Pane with Low-E 30 0.350 11 Window 7: Metal Frame:Double Pane with Low-E 36 0.370 13 Door 1: Glass 74 0.350 26 Door 2: Solid 153 0.350 54 Wall 2: Wood Frame, 16" o.c.850 34.0 0.0 0.046 39 1,521 0.0 10.0 0.075 35 Project Title: 17052.00 430 W Hallam Residence Data filename: P:\Current Projects\17052.00 - 430 W Hallam Residence\Drawings\In-Out\2021-0122 - Res Check\17052 Res Check.rck Page 1 of 2 08/30/22Report date: Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Ceiling 1: Cathedral Ceiling 3,890 49.0 0.0 0.022 86 Ceiling 2: Flat Ceiling or Scissor Truss 683 50.0 0.0 0.026 18 Crawl Floor: Slab-On-Grade:Unheated Insulation depth: 4.0' 266 5.0 0.745 198 garage floor: Slab-On-Grade:Heated Insulation depth: 4.0' 63 5.0 0.745 47 Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.7.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Title: 17052.00 430 W Hallam Residence Data filename: P:\Current Projects\17052.00 - 430 W Hallam Residence\Drawings\In-Out\2021-0122 - Res Check\17052 Res Check.rck Page 2 of 2 08/30/22Report date: 8/30/22