HomeMy WebLinkAboutFile Documents.430 W Hallam St.0291.2017 (34).ARBKREScheck Software Version 4.7.1
Compliance Certificate
Project 17052.00 430 W Hallam Residence
Energy Code:2015 IECC
Location:Aspen, Colorado
Construction Type:Single-family
Project Type:New Construction
Conditioned Floor Area:7,650 ft2
Glazing Area 20%
Climate Zone:7 (9922 HDD)
Permit Date:
Construction Site:
430 W Hallam St
Aspen, CO 81611
Owner/Agent:
430 HALLAM LLC
Designer/Contractor:
KARA THOMPSON
FORUM PHI ARCHITECTURE
914-494-8698
KTHOMPSON@FORUMPHI.COM
Permit Number:
Compliance: Passes using UA trade-off
4.9% Better Than Code Maximum UA:1235 Your UA:1175
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Compliance:
Envelope Assemblies
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value U-Factor UA
Basement Wall 1: Solid Concrete or Masonry
Wall height: 12.0'
Depth below grade: 12.0'
Insulation depth: 12.0'
2,808 12.5 10.0 0.031 85
Window 2: Metal Frame:Double Pane with Low-E 76 0.300 23
Wall 1: Wood Frame, 16" o.c.5,962 20.0 5.0 0.044 199
Window 1: Metal Frame:Double Pane with Low-E 8 0.240 2
Window 2: Metal Frame:Double Pane with Low-E 71 0.280 20
Window 3: Metal Frame:Double Pane with Low-E 358 0.290 104
Window 4: Metal Frame:Double Pane with Low-E 702 0.300 211
Window 5: Metal Frame:Double Pane with Low-E 14 0.310 4
Window 6: Metal Frame:Double Pane with Low-E 30 0.350 11
Window 7: Metal Frame:Double Pane with Low-E 36 0.370 13
Door 1: Glass 74 0.350 26
Door 2: Solid 153 0.350 54
Wall 2: Wood Frame, 16" o.c.850 34.0 0.0 0.046 39
1,521 0.0 10.0 0.075 35
Project Title: 17052.00 430 W Hallam Residence
Data filename: P:\Current Projects\17052.00 - 430 W Hallam Residence\Drawings\In-Out\2021-0122 -
Res Check\17052 Res Check.rck
Page 1 of 2
08/30/22Report date:
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value U-Factor UA
Ceiling 1: Cathedral Ceiling 3,890 49.0 0.0 0.022 86
Ceiling 2: Flat Ceiling or Scissor Truss 683 50.0 0.0 0.026 18
Crawl Floor: Slab-On-Grade:Unheated
Insulation depth: 4.0'
266 5.0 0.745 198
garage floor: Slab-On-Grade:Heated
Insulation depth: 4.0'
63 5.0 0.745 47
Name - Title Signature Date
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.7.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Project Title: 17052.00 430 W Hallam Residence
Data filename: P:\Current Projects\17052.00 - 430 W Hallam Residence\Drawings\In-Out\2021-0122 -
Res Check\17052 Res Check.rck
Page 2 of 2
08/30/22Report date:
8/30/22