Loading...
HomeMy WebLinkAboutFile Documents.210 S West End St.0011-2021-BCHO (12)IR-1.0 job - 0189 drawn - TB 21 0 S W E S T E N D S T R E E T AS P E N , C O L O R A D O piñon sage landscape architects 700 redstone ave carbondale, CO, 81623 devin@pinonsage.com (970) 379.0816 IRRIGATION NOTES AND SCHEDULE issue date - 01/27/21 revisions description#dateDIRECTORY IRRIGATION SCHEDULE IR-1.0 IRRIGATION NOTES IR-1.0 IRRIGATION PLAN IR-1.1 IRRIGATION DETAILS IR-2.0 IRRIGATION DETAILS IR-2.1 AND CHART R Know what's below. Call before you dig. CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. 1.DRAWINGS AND BASE INFORMATION ALL BASE AND PLANTING INFORMATION HAVE BEEN PROVIDED BY PINION SAGE. THE CONTRACTOR IS RESPONSIBLE TO NOTIFY HYDROSYSTEMS*KDI OF ANY DISCREPANCIES BETWEEN THE UTILITY OR PLANTING PLANS AND THE IRRIGATION PLAN. IF CONTRACTOR FAILS TO NOTIFY HYDROSYSTEMS*KDI AND MAKES CHANGES TO THE IRRIGATION SYSTEM DESIGN, HE ASSUMES ALL COSTS AND LIABILITIES ASSOCIATED WITH THOSE FIELD CHANGES. REFER TO SPECIFICATIONS FOR ADDITIONAL PROJECT REQUIREMENTS. CONTACT IRRIGATION CONSULTANT FOR CURRENT SPECIFICATIONS IF NOT PROVIDED. 2.SYSTEM PRESSURE - CITY OF ASPEN FIRE PROTECTION DISTRICT HAS INDICATED THAT THE STATIC WATER PRESSURE IN THIS AREA SHOULD BE 94 PSI MIN AT THE CITY MAIN IN THE STREET. THE CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY PRESSURE PRIOR TO COMMENCING ANY CONSTRUCTION AND NOTIFY HYDROSYSTEMS*KDI OF ANY VARIANCE FROM THE STATED PRESSURE IMMEDIATELY. WRITTEN DOCUMENTATION OF PRESSURE TEST AND RESULTS SHALL BE PROVIDED TO HYDROSYSTEMS*KDI AT CONSTRUCTION ONSET. IF CONTRACTOR FAILS TO FIELD VERIFY PRESSURE AND/OR NOTIFY HYDROSYSTEMS*KDI OR ANY VARIATIONS FROM THIS PRESSURE, THEN HE ASSUMES ALL CONSTRUCTION AND ENGINEERING COSTS ASSOCIATED WITH SYSTEM MODIFICATIONS REQUIRED TO ACCOMMODATE ACTUAL SITE PRESSURE. THIS SYSTEM HAS BEEN DESIGNED FOR A REQUIRED STATIC PRESSURE OF 70 PSI MINIMUM AT THE POINT OF CONNECTION. 3.IRRIGATION SYSTEM OPERATION INTENT - THIS IRRIGATION SYSTEM HAS BEEN DESIGNED TO IRRIGATE THE ESTABLISHED LANDSCAPE WITHIN A THREE NIGHT PER WEEK, SIX HOUR PER NIGHT WATERING WINDOW. ESTABLISHMENT WATERING WILL REQUIRE UP TO TWICE AS MUCH IRRIGATION FOR A FOUR TO SIX WEEK PERIOD. THE DESIGN IS BASED ON THE FOLLOWING PROJECTED WEEKLY APPLICATION RATES AFTER ESTABLISHMENT. THESE FIGURES ARE BASED ON A 30-YEAR AVERAGE WEATHER DATA AND WILL NEED TO BE ADJUSTED DUE TO SEASONAL CHANGES AND WEATHER CONDITIONS ABOVE AND BELOW THE AVERAGE VALUES UTILIZED. FESCUE 1.72" PER WEEK PEAK SEASON ORNAMENTAL PLANTINGS 0.78" PER WEEK PEAK SEASON 4.EQUIPMENT INSTALLATION - ALL IRRIGATION EQUIPMENT MUST BE INSTALLED WITHIN PROPERTY LIMITS AND WITHIN LANDSCAPED AREAS. ANY EQUIPMENT OTHER THAN VALVE BOXES OR SLEEVING THAT CONTAINS PIPE OR WIRES SHOWN OUTSIDE OF THESE LIMITS IS SHOWN IN THAT LOCATION FOR GRAPHICAL CLARITY ONLY. ALL VALVE BOXES SHALL BE INSTALLED A MINIMUM OF 2'-0" FROM EDGE OF ANY PAVED SURFACES UNLESS SPECIFICALLY INDICATED ON PLANS. BOXES INSTALLED IN OPEN TURF AREAS SHALL BE KEPT TO EDGES AND STAKED FOR REVIEW IF ALONG HIGH TRAFFIC AREAS. ALL VALVE BOXES SHALL BE PLACED A MINIMUM OF 3'-0" FROM THE CENTERLINE OF ANY DRAINAGE SWALE. ALL VALVE BOXES WITHIN PAVEMENT SHALL BE TIER 15 RATED BOXES FOR HEAVY DUTY NON-DELIBERATE TRAFFIC. BOX LID COLOR SHALL MATCH ADJACENT MATERIALS, I.E. GREEN IN TURF, TAN IN WOOD MULCH, GRAY IN STONE MULCH, PURPLE FOR RECLAIMED WATER SYSTEMS (IF REQUIRED). REFER TO LANDSCAPE PLANS FOR MATERIAL COLORS AND TYPES. ALL BOXES SHALL BE INSTALLED TO BE FLUSH WITH GRADE AND IN AN ORDERLY MANNER. 5.PIPING INSTALLATION - IRRIGATION PIPING SHALL MAINTAIN A MINIMUM DISTANCE FROM BUILDING FOUNDATIONS OF 5 FEET OR AS DESCRIBED IN SOILS REPORT, WHICHEVER IS GREATER. NO SPRAY IRRIGATION SHALL OCCUR WITHIN 5 FEET OF THE FOUNDATION. NO DRIP IRRIGATION SHALL OCCUR WITHIN 5 FEET OF THE FOUNDATION UNLESS SOIL MOISTURE SENSORS ARE INSTALLED ON VALVES SERVICING THESE AREAS. MAINLINE AND LATERAL PIPING SHALL STAY OUT OF DRIPLINES OF TREES OR HAVE WRITTEN CONSENT OF THE CITY FORESTER. 6.MANUAL DRAIN VALVES - CONTRACTOR TO INSTALL ONE MANUAL DRAIN VALVE ON PRESSURE SUPPLY LINE DIRECTLY DOWNSTREAM OF BACKFLOW PREVENTER AND AT ALL LOW POINTS AND DEAD ENDS OF PRESSURE SUPPLY PIPING TO ENSURE COMPLETE DRAINAGE OF SYSTEM. CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THESE LOCATIONS IN-FIELD AND INSTALLATION LOCATIONS SHALL BE NOTED ON AS-BUILTS. FOR INTERIOR MOUNTED BACKFLOW PREVENTER LOCATIONS, INSTALL ONE BOILER DRAIN VALVE DOWNSTREAM OF BACKFLOW PREVENTER. 7.POP-UP SPRAY NOZZLES - CONTRACTOR TO INSTALL PLASTIC NOZZLES ON ALL POP-UP SPRAY HEADS. INSTALL 15 U-SERIES NOZZLES ON ALL HEADS SPACED AT 12' TO 14'. INSTALL 12 U-SERIES NOZZLES ON ALL HEADS SPACED 10' TO 11'. INSTALL 10 SERIES NOZZLES ON ALL HEADS SPACED AT 8' TO 9'. INSTALL 8 SERIES NOZZLES ON ALL HEADS SPACED AT 6' TO 7'. INSTALL 5' NOZZLES ON ALL HEADS SPACED AT 5'. INSTALL SIDE STRIP NOZZLES ON ALL HEADS WITH AN "S" DESIGNATION AND RIGHT AND LEFT CORNER STRIP NOZZLES ON ALL HEADS WITH AN "L" OR "R" DESIGNATION. VARIABLE ARC NOZZLES SHOULD BE UTILIZED ADJACENT TO CURVILINEAR SHRUB BEDS OR FOR ANY ANGLES THAT ARE NOT A STANDARD NOZZLE ANGLE. WHERE INDICATED, INSTALL LOW FLOW SQ SERIES SQUARE NOZZLES AT SPACING SHOWN. 8.DRIP IRRIGATION - REFER TO IRRIGATION DETAIL SHEET FOR DRIP EMITTER QUANTITIES AND DRIP TUBING FLOW AND PLACEMENT. 9.UNLABELED PIPING - ALL UNLABELED LATERAL PIPING SHALL BE 1" MINIMUM UNLESS OTHERWISE NOTED. 10.SLEEVING - ALL SLEEVING UNDER PAVED SURFACES SHOWN ON PLANS IS BY CONTRACTOR UNLESS OTHERWISE NOTED. SLEEVING SHALL BE INSTALLED IN THE SIZES AND QUANTITIES SHOWN ON PLANS OR BASED ON THE SCHEDULE BELOW. WHERE SLEEVES ARE SHOWN, BUT NOT LABELED, FOLLOW THE SCHEDULE BELOW. ALL MAINLINE, CONTROL WIRES AND DRIP LINES UNDER PAVED SURFACES ARE TO BE INSTALLED IN SLEEVING. ALL MAINLINE SLEEVE LOCATIONS TO INCLUDE A SEPARATE WIRE SLEEVE. SLEEVED PIPE SIZE/WIRE QUANTITY REQUIRED SLEEVE SIZE & (QUANTITY) 3 4" - 11 4" PIPING 2" PVC (1) 1-25 CONTROL WIRES 2" PVC (1) 11.SPARE CONTROL WIRES - CONTRACTOR SHALL EXTEND THREE SPARE WIRES (ONE COMMON AND 2 CONTROL WIRES) FROM EACH CONTROLLER TO THE END OF THE MAINLINE SERVING THAT CONTROLLER OR AS SHOWN ON THE PLANS. INSTALL SPARE WIRES IN 10" ROUND VALVE BOX WITH QUICK COUPLING VALVE. REFER TO SPECIFICATIONS FOR WIRE COLOR. SEE IRRIGATION SCHEDULE FOR ADDITIONAL INFORMATION. 12.ADJUSTMENT - CONTRACTOR SHALL FINE TUNE/ADJUST THE IRRIGATION SYSTEM TO REDUCE/AVOID OVERSPRAY ONTO HARD SURFACES BY ADJUSTING NOZZLE DIRECTION AND NOZZLE RADIUS. 13.PLANS AND SPECIFICATIONS - CONTRACTOR RESPONSIBLE TO ENSURE WORK CONFORMS TO PLANS AND SPECIFICATIONS. AT ONSET OF CONSTRUCTION, VERIFY PLANS ARE CURRENT. WHERE REQUIRED BY CITY OR TOWN, CONTRACTOR SHALL CONSTRUCT ONLY OFF CITY OR TOWN STAMPED PLANS. REVISIONS TO CITY OR TOWN STAMPED PLANS SHALL CONFORM TO CITY OR TOWN FIELD CHANGE PROCEDURES AND DOCUMENTATION. 14.WATER BUDGETS AND PROJECTIONS - HYDROSYSTEMS-KDI HAS BASED THE IRRIGATION DESIGN AND THE ASSOCIATED PROJECTED WATER USE UPON SUCH FACTORS AS CITY OR WATER DISTRICT IMPOSED REQUIREMENTS, PUBLISHED PLANT SPECIES WATER NEEDS, SELECTED IRRIGATION METHOD EFFICIENCIES AS REPORTED BY INDEPENDENT TESTING FACILITIES, HISTORICAL WEATHER DATA FOR THE PROJECT LOCATION, AND PROPER MAINTENANCE PROCEDURES. HYDROSYSTEMS*KDI IS NOT RESPONSIBLE, AND ACCEPTS NO RESPONSIBILITY, FOR THE ACTUAL WATER USAGE VARIATION THAT IS A RESULT OF FIELD MODIFICATIONS TO THE SYSTEM NOT MATCHING CONSTRUCTION DOCUMENTS, IMPROPER MAINTENANCE, WASTE DUE TO SYSTEM DAMAGE OR VANDALISM, OR WEATHER CONDITIONS THAT DEVIATE FROM PUBLISHED 30 YEAR HISTORICAL AVERAGES. 13.ASPEN WATER EFFICIENT IRRIGATION DESIGNER STATEMENT - I HAVE COMPLIED WITH THE CRITERIA OF THE WATER EFFICIENT LANDSCAPING STANDARDS AND APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE IRRIGATION DESIGN PLAN. 14.IRRIGATION WITHIN ROW - CONTRACTOR IS RESPONSIBLE TO ENSURE THAT ANY IRRIGATION WITHIN THE ROW AREA (BETWEEN STREET AND THE PROPERTY LINE) IS TO BE ON SEPARATE CONTROL VALVES THAN THOSE WITHIN THE PROPERTY LINE. 15.IRRIGATION AND EXISTING TREES - ALL IRRIGATION WORK PERFORMED WITHIN THE DRIP LINE OF EXISTING TREES REQUIRES HAND GRUBBING NO DEEPER THAN SIX INCHES (6") AND MUST BE AS FAR FROM TREE TRUNK AS PRACTICALLY POSSIBLE. DO NOT CUT ROOTS 2'' AND GREATER IN DIAMETER WITHOUT THE EXPRESS WRITTEN CONSENT OF FORESTER. 16.ALL DISTURBANCES WITHIN DRIPLINES OF EXISTING TREES SHALL BE REVIEWED BY THE CITY FORESTER. IRRIGATION SCHEDULE SYMBOL MANUFACTURER MODEL NO.DESCRIPTION DETAIL NO. RAIN BIRD RD-06-S-P30 WITH MPR- SERIES NOZZLE POP-UP SPRAY HEAD 8 RAIN BIRD/HUNTER RD-06-S-P40 WITH HUNTER ROTATOR M1000 NOZZLES POP-UP ROTATOR SPRAY HEAD 8 RAIN BIRD PEB-PRS-D ELECTRIC CONTROL VALVE 7 RAIN BIRD 44-LRC QUICK COUPLING VALVE 5 HUNTER I-CORE-M - 16 STATION MODEL ELECTRIC CONTROLLER 2 HUNTER SOLAR SYNC - WSS-SEN WEATHER SENSOR DEVICE 3 FEBCO 860U RP BACKFLOW PREVENTER 1 N/S OLDCASTLE / CARSON REFER TO SPECIFICATIONS AND DETAILS VALVE BOXES VARIOUS N/S MATCO 201X MANUAL DRAIN VALVE 6 LINE SIZE - 21 2'' AND SMALLER GATE VALVE 4 RAIN BIRD PESB-PRS MASTER CONTROL VALVE 1 DATA INDUSTRIAL IR250B (1")FLOW SENSOR 1 SCHEDULE 40 PVC PVC MAINLINE 10 TYPE K COPPER HARD COPPER PIPE 1 #100 NSF POLY LATERAL 10 SCHEDULE 40 PVC PVC SLEEVING 11 RAIN BIRD XCZ-PRB-COM DRIP VALVE ASSEMBLY 12 TORO BLUE STRIPE POLY DRIP TUBING -3 4" MIN. WIDTH 13 DRIP LINE BLOW-OUT STUB 15 N/S RAIN BIRD XERI-BUG DRIP EMITTERS 13 NETAFIM TLHCVXR5-1201 ROWS SPACED 12" MIN, SPACED EVENLY AT SHRUB BEDS AND 18'' ROWS FOR HATCH LABELED EXISTING SHADE GROUND COVERS SUBSURFACE IN-LINE DRIP PIPE 14 & 16 NETAFIM TL075FTEE DRIPPERLINE CONNECTION 14 & 16 BUILDING PENETRATION - THROUGH A NIBCO T585-70-SV (1'')LOCKABLE BALL VALVE 9 #1 #1 #1 #1 A W FS GPM CONTROL VALVE SIZE CONTROLLER & STATION NO. A (controller)NUMBER OF SPARE WIRES - 2 CONTROL AND 1 SPARE WIRES TO WHICH CONTROLLER - SEE CONSTRUCTION NOTES3 IRRIGATION CONSTRUCTION NOTES 860 Tabor Street, Suite 200 Lakewood, Colorado 80401 o: 303.980.5327 www.hydrosystemskdi.com Irrigation Consulting & Water Management CONSTRUCTION DRAWING 03/01/2021 U P ADU GARAGE MASTER AR dr 1'' A14 dr 1'' A13 dr 1'' A12 dr 1'' A11 8 1'' A5 dr 1'' A7 3 1'' A4 dr 1'' A2 dr 1'' A1 (1)2'' (1)2'' (3)2'' (2)2'' (3)2'' dr 1'' A10 (1)2'' FS #1 #1 #1#1 #1 #1 #1 #1 #1#1 #1 dr 1'' A9 dr 1'' A8 (2)2'' dr 1'' A31'' 1'' 1'' 1''1'' 1'' 1'' 2 1'' A6 (1)2'' IR-1.1 0'5'10'20' Scale: 1"=20'-0" N job - 0189 drawn - TB 21 0 S W E S T E N D S T R E E T AS P E N , C O L O R A D O piñon sage landscape architects 700 redstone ave carbondale, CO, 81623 devin@pinonsage.com (970) 379.0816 IRRIGATION PLAN issue date - 01/27/21 revisions description#date Xref .\Xrefs\20-0421\z\LIFT-630WHA-LCD-SHEET SETUP_2020-04-22 - Standard\LIFT-630WHA-X-TBLOCK.dwg DIRECTORY IRRIGATION SCHEDULE IR-1.0 IRRIGATION NOTES IR-1.0 IRRIGATION PLAN IR-1.1 IRRIGATION DETAILS IR-2.0 IRRIGATION DETAILS IR-2.1 AND CHART R Know what's below. Call before you dig. CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. A CONTROLLER LOCATION "A" WALL MOUNT ONE CONTROLLER (REFER TO SCHEDULE FOR MODEL & STATION COUNT), AT INDICATED LOCATION. COORDINATE A 120 VOLT POWER CIRCUIT WITH ELECTRICAL CONTRACTOR FROM RESIDENCE. ELECTRICAL WIRE/CONDUIT POWER CONNECTION TO CONTROLLER IS BY CONTRACTOR WITH WORK CONFORMING TO LOCAL CODES. EXTEND PE89 SHIELDED CABLE FROM THE FLOW SENSOR AND 4 #14 UFUL WIRES (TWO BLUE AND TWO ORANGE) FROM MASTER VALVE TO ASSOCIATED CONTROLLER. CONNECT WIRES TO THE APPROPRIATE SENSOR INPUT PORTS. FEES AND PERMITS ASSOCIATED WITH WORK ARE TO BE OBTAINED AND PAID BY CONTRACTOR. FINAL CONTROLLER LOCATION SHALL BE APPROVED BY OWNER PRIOR TO INSTALLATION. MOUNT ONE WEATHER SENSOR ON BUILDING WHERE THERE IS 20 FT. OF CLEARANCE FROM ANY OVERHANG OR OBSTRUCTING FEATURE. FINAL WEATHER SENSOR LOCATION SHALL BE APPROVED BY OWNER PRIOR TO INSTALLATION. A ANY DISTURBANCE UNDER EXISTING TREES WILL REQUIRE REVIEW AND APPROVAL OF CITY FORESTER PRIOR TO CONSTRUCTION. HAND GRUBBING ONLY UNDER EXISTING TREES. NO HEAVY EQUIPMENT ALLOWED. POINT OF CONNECTION #1 - 3/4" PEAK FLOW REQUIREMENT: 10 GPM. REQUIRED STATIC PRESSURE: 94 PSI MIN. TIE ONTO COPPER STUB WITH LOCKABLE ISOLATION VALVE THIS APPROXIMATE LOCATION AND EXTEND PVC MAINLINE AS SHOWN. COORDINATE WITH PLUMBING CONTRACTOR. ASSURE IRRIGATION CONNECTION IS MADE AFTER METER AND PRIOR TO ANY PRESSURE REDUCING VALVES AND BACKFLOW PREVENTERS FOR HOUSE. INSTALL ONE 3/4'' REDUCED PRESSURE BACKFLOW PREVENTER WITH AIR GAP PLUMBED TO DRAIN PER MANUFACTURER'S RECOMMENDATIONS, ONE BOILER DRAIN VALVE, ONE 1" FLOW SENSOR, ONE 1" MASTER VALVE, ONE ISOLATION VALVE AND EXTEND 1" COPPER LATERAL TO BUILDING EXTERIOR. EXTEND ONE PE89 SHIELDED CABLE FROM FLOW SENSOR TO DATA RETRIEVAL UNIT LOCATED IN ASSOCIATED CONTROLLER. EXTEND 4 UFUL14# WIRE (TWO ORANGE AND TWO BLUE) AND CONNECT 2 OF THE WIRES FROM THE MASTER VALVE TO THE DATA RETRIEVAL BOARD IN ASSOCIATED CONTROLLER. SEE DETAIL SHEET FOR REQUIRED PIPE LENGTHS UPSTREAM AND DOWNSTREAM OF FLOW SENSING UNIT. WORK SHALL CONFORM TO LOCAL CODE. FEES AND PERMITS ASSOCIATED WITH WORK ARE TO BE OBTAINED AND PAID FOR BY CONTRACTOR. FINAL BACKFLOW PREVENTER LOCATION SHALL BE APPROVED BY OWNER PRIOR TO INSTALLATION. 1 1 860 Tabor Street, Suite 200 Lakewood, Colorado 80401 o: 303.980.5327 www.hydrosystemskdi.com Irrigation Consulting & Water Management DRIP ZONE A12 REQUIRES 12'' SWING PIPE SUPPLY IN A 1'' COPPER RISER SLEEVE TO RAISED PLANTER. COORDINATE WITH LANDSCAPE ARCHITECT, TOWN OF ASPEN REQUIRED ACCESSIBLE LOCKABLE IRRIGATION BALL BALL VALVE LOCATION. CONSTRUCTION DRAWING LOCATE AND TIE ONTO EXISTING IRRIGATION LATERAL SUPPLYING THE EXISTING TREE LAWN IRRIGATION AT THIS APPROXIMATE LOCATION. CONTROLLER WIRE SLEEVE FOR MASTER VALVE, FLOW SENSOR AND CONTROL WIRES AS NEEDED. 03/01/2021 It appears that the graphic scale is correct and drawing is at 1"=10'. Revise. This ROW area appears to be landscaped with turf, perennials and a tree. Please include species and irrigation on all plans and calculations. AS per WELS Section 5.2.3 turf areas less than 10 feet in any dimension shall not be overhead irrigated. Revise to subsurface irrigation for turf. Allow generous mulched tree rings to reduce impacts to tree roots. WELS Section 5.2.7 requires separate irrigation valves for trees. Revise plans accordingly. IR-2.0 job - 0189 drawn - TB 21 0 S W E S T E N D S T R E E T AS P E N , C O L O R A D O piñon sage landscape architects 700 redstone ave carbondale, CO, 81623 devin@pinonsage.com (970) 379.0816 IRRIGATION DETAILS issue date - 01/27/21 revisions description#date R Know what's below. Call before you dig. CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. NOTE: DIAMETERS OF BALL VALVES, PVC FITTINGS AND NIPPLES SHALL EQUAL ELECTRIC CONTROL VALVE DIAMETER. VALVE BOXES SHALL BE INSTALLED PARALLEL OR PERPENDICULAR TO ADJACENT SIDEWALKS AND HARD SURFACES WHERE APPLICABLE. APPLY TEFLON TAPE TO ALL MALE THREADED FITTINGS AND THREADED NIPPLES. RECTANGULAR VALVE BOX. BRAND LID WITH CONTROLLER & STATION #. REFER TO TECHNICAL SPECIFICATIONS. CENTER BOX OVER ASSEMBLY. PROVIDE 12" CONTINUOUS COILS OF ALL "MAINTENANCE" SPARE CONTROL/COMMON WIRING WITHIN VALVE BOX PVC BALL VALVE - FIPTxFIPT 3 4" CRUSHED GRAVEL SUMP - FILL BOX TO BOTTOM OF VALVE BODY SCH. 80 PVC NIPPLE - LENGTH AS REQUIRED SERVICE TEE - SOLVENT WELD OR GASKETED FITTING - REFER TO SPECIFICATIONS CONTROL WIRE BUNDLE POLY LATERAL - SWEEP TO SPECIFIED DEPTH STAINLESS STEEL CLAMP - INSTALL TWO CLAMPS ON 112" & 2" DIA. FITTINGS PVC MIPTxINSERT ADAPTER ELECTRIC CONTROL VALVE 4" FINISH GRADE 7ELECTRIC CONTROL VALVE 24V - Poly Lateral FINISH GRADE APPLY TEFLON TAPE TO ALL MALE THREADED PVC FITTINGS AND ALL NIPPLES 3 4" CRUSHED GRAVEL SUMP 1 CU. FT. 2" VALVE MARKER 10" ROUND VALVE BOX - BRAND THE LETTER "D' IN LID. REFER TO TECHNICAL SPECIFICATIONS. 2" CL 160 PVC ACCESS SLEEVE - LENGTH AS REQUIRED 3 4" FxF SCH. 80 PVC 90 ELL (2) 3 4"xCL PVC NIPPLE SCH. 80 (2) 3 4"x6" SCH. 80 GALVANIZED STEEL NIPPLE 3 4" BRASS GLOBE VALVE 3 4" MxF SCH. 40 PVC 90 ELL SOIL BLANKET COVERING SUMP 3 4"x4" PVC NIPPLE SCH. 80 3 4" CRUSHED GRAVEL SUMP. SEE TECHNICAL SPECIFICATIONS FOR SUMP SIZE PVC PRESSURE MAINLINE MANUAL DRAIN VALVE 6 ADJUSTABLE LENGTH MOUNTING ARM SECURE BRACKET TO EAVE PER MANUFACTURER'S RECOMMENDATIONS. BUILDING EAVE NOTE: MOUNT SENSOR RECEIVER PER CONTROLLER DETAIL. SOLAR SYNC SENSOR - TOP OF SENSOR TO BE ABOVE GUTTER AND/OR ANY OBSTRUCTIONS WEATHER SENSOR 3EAVE MOUNTED - SolarSync FINISH GRADE 2" 3" 10" ROUND VALVE BOX. BRAND "GV" ON LID OF VALVE BOX. REFER TO TECHNICAL SPECIFICATIONS. GATE VALVE W/ CROSS HANDLE AND SOLID WEDGE DISC. 3 4" CRUSHED GRAVEL SUMP - FILL BOX TO WITHIN 2" OF TOP OF 6" PVC ACCESS SLEEVE∅ 6" CLASS 160 PVC SLEEVE BOTTOM TO BE NOTCHED AND CONTACT TOP OF PRESSURE MAINLINE PVC PRESSURE MAINLINE SCH. 40 PVC MALE ADAPTER (2) - SIZE TO EQUAL GATE VALVE DIAMETER UNDISTURBED SOIL GATE VALVE 4 3" 2" 10" ROUND VALVE BOX BRAND "QC" INTO VALVE BOX LID. REFER TO TECHNICAL SPECIFICATIONS. 3 4" CRUSHED GRAVEL SUMP - FILL BOX TO WITHIN 2" OF BOTTOM OF QCV LID 1" BRASS NIPPLE LENGTH AS REQUIRED LINE SIZE BRASS COUPLING 1 2"x12" REBAR STABILIZING STAKE TYPICAL TWO SIDES PER QUICK COUPLING VALVE LOCATION LASCO #G 13S-212 UNITIZED SWING JOINT W/ BRASS INSERT STABILIZER ELBOW. PROVIDE WITH 1" MIPT INLET PRESSURE MAINLINEx1" PVC SERVICE TEE - SOLVENT WELD OR GASKETED FITTING REFER TO SPECIFICAIONS QUICK COUPLING VALVE FINISH GRADE APPLY TEFLON TAPE TO ALL THREADED NIPPLES QUICK COUPLING VALVE 5 2'' TYPE ''L'' RIGID COPPER TUBING SECURE BACKFLOW PREVENTER ASSEMBLY FASTEN TUBING TO FINISH FLOOR @ 18'' 0.C. AND COPPER TUBING TO WALL VIA UNI-STRUT CHANNEL AND COPPER FASTENERS AT 6 FT. O.C. VENT BACKFLOW PREVENTER DRAIN INTO POINT OF CONNECTION - INTERIOR FINISH FLOOR FLOOR DRAIN FEBCO 860U REDUCED PRESSURE BACKFLOW PRESSURE REDUCING VALVE (AS REQUIRED, RE:PLAN) PREVENTER WITH INTEGRAL UNIONS FLOW FEBCO 601 AIR GAP DRAIN CxM ADAPTER - LINE DIA. (FOUR REQ'D.) 12'' MIN. CxCxF TEE FLOW SENSOR 3/4'' I.P. MALE BRASS BOILER DRAIN W/ WHEEL HANDLE BALL VALVE FOR SHUT-OFF TYPE K HARD COPPER TO PENETRATION LOCATIONS WIRE CONDUIT FROM CONTROLLER LINE SIZE MASTER VALVE TYPE ''K'' RIGID COPPER - CONNECT TO BUILDING COLD WATER SERVICE LINE DOWNSTREAM OF WATER METER, UPSTREAM OF ANY PRESSURE REDUCING VALVES OR OTHER BUILDING SERVICE EQUIPMENT NOTE: REFER TO TECHNICAL SPECIFICATIONS FOR MINIMUM TRENCH WIDTHS.FINISH GRADE ROTOR LATERAL PIPING BACKFILL MATERIAL (TYP.) 4-6" BODIES: 14" 12" BODIES: 18" MAINLINE 4-6" BODIES: 18" 12" BODIES: 24" CONTROL WIRE BUNDLE OR TWO WIRE COMMUNICATION CABLE (PER SPECIFICATIONS) 24" SPRAY HEAD LATERAL PIPING OR DRIP LINE HEADER. 1024"TYPICAL TRENCH B A ROUGH GRADE C NOTE: ·ALL SLEEVE MATERIAL PER IRRIGATION SCHEDULE, SIZE AS NOTED ON PLAN. ·INSTALL SLEEVES IN SIDE-BY-SIDE CONFIGURATION WHERE MULTIPLE SLEEVES ARE TO BE INSTALLED. SPACE SLEEVES 4" TO 6" APART. DO NOT STACK SLEEVES VERTICALLY. ·CONTRACTOR TO COORDINATE WITH FLATWORK INSTALLER TO BRAND A "V" IN SIDEWALK OR CURB AT BOTH ENDS OF SLEEVE CROSSING. ·SLEEVING THROUGH OR UNDER RETAINING WALLS, PLANTER WALLS, POND LINING, OR WATER QUALITY AREAS SHALL BE COORDINATED WITH CIVIL WORK AT APPROXIMATE LOCATIONS SHOWN. PAVED SURFACE CURB AND GUTTER (IF APPLICABLE) 2" PVC PIPE SLEEVE MARKER - INSTALL AT BOTH ENDS OF EACH SLEEVE LOCATION AND EXTEND AT LEAST 3' ABOVE GRADE. SPRAY EXPOSED PORTION OF MARKER WITH GREEN FLUORESCENT PAINT. REMOVE AT FINAL INSTALL. SEAL ENDS OF SLEEVE WITH CLOTH DUCT TAPE (TYPICAL) PVC SLEEVING (TYPICAL) IRRIGATION SLEEVING 24" MIN. 12" MIN. 36" MIN. 11 PVC CONDUIT W/ SWEEP ELL (TYP. UNDERGROUND LOCATIONS) - 2 EACH LOCATION - ONE 2" PVC SCH 40 DIRECT BURIAL CONDUIT STUB-OUT FOR 24V VALVE CONTROL WIRING AND ONE 3 4" PVC CONDUIT FOR 120V POWER SUPPLY IN DIRECT BURIAL CONDUIT AS PER CITY CODE. FINISH GRADE EMT MALE ADAPTER & PVC FEMALE ADAPTER SECURE CONDUIT TO WALL 18" O.C. EMT CONDUIT - SIZE TO ACCOMMODATE CONTROL WIRE QUANTITY EMT MALE ADAPTER W/ WASHER & LOCK RING ELECTRIC CONTROLLER SECURE CONTROLLER TO WALL WITH ANCHOR BOLTS 18'' 54" MIN. 60" MAX. ELECTRIC CONTROLLER 2EXTERIOR WALL MOUNT LOCKABLE BALL VALVE FINISH GRADE 3"-4" BRASS BALL VALVE - PVC x MIP ADAPTERS (2 EACH) DIAMETER TO EQUAL PIPE DIAMETER 3 4" CRUSHED GRAVEL SUMP - 1 CU. FT. 6" CLASS 160 PVC SLEEVE. BOTTOM TO BE NOTCHED AND CONTACT TOP OF PRESSURE MAINLINE PVC PRESSURE MAINLINE OR LATERAL 10" ROUND VALVE BOX - BRAND "BV" ON LID OF VALVE BOX. REFER TO TECHNICAL SPECIFICATIONS. PAD LOCK 9 3" SET BOTTOM OF CAP AT GRADE CURB & GUTTER, SIDEWALK OR HARD SURFACE WHERE APPLICABLE POP-UP SPRAY HEAD 12" MALExBARB ELL 12" DIA. POLYETHYLENE SWING PIPE (4 L.F. MAXIMUM LENGTH) 12" MALExBARB ADAPTER POLY LATERAL PIPING W/ LINE SIZEx\" INSERTxFIPT FITTING AND CLAMPS NOTE: ·SET HEAD PERPENDICULAR TO FINISH GRADE. ·APPLY TEFLON TAPE TO MALE PVC THREADED FITTINGS. ·DOUBLE CLAMP 11 2" & 2" DIAMETER FITTINGS. POP-UP SPRAY HEAD 8SWING PIPE - POLY 1 CONSTRUCTION DRAWING 03/01/2021 IR-2.1 job - 0189 drawn - TB 21 0 S W E S T E N D S T R E E T AS P E N , C O L O R A D O CONSTRUCTION DRAWING piñon sage landscape architects 700 redstone ave carbondale, CO, 81623 devin@pinonsage.com (970) 379.0816 IRRIGATION DETAILS issue date - 01/27/21 revisions description#date 3 4" PVC BALL VALVE WITH 3 4" PVC INSxMIPT ADAPTER AND S.S. CLAMP 3 4" DRIP TUBING - COIL SUFFICIENT LENGTH IN BOX TO EXTEND HOSE ADAPTER OUTSIDE OF VALVE BOX. 3 4" WASHED RIVER ROCK SUMP (1 CU. FT.) INSERT TEE WITH CLAMPS 10" ROUND VALVE BOX WITH COVER - BRAND "DB" INTO VALVE BOX LID. REFER TO TECHNICAL SPECIFICATIONS. SECTIONPLAN DISTANCES VARY: CONTRACTOR SHALL LOCATE FLUSH VALVE BOX TO BE SCREENED BY PLANT MATERIAL AND ACCESSIBLE. OPERATIONAL INDICATOR SHALL BE LOCATED FOR EASY VISIBILITY DURING OPERATION PLANT MATERIAL INDICATOR HEAD PLANTER BED WALL OR EDGER FLUSH VALVE POLY PIPE FROM EXHAUST HEADER OR DRIP LATERAL FINISH GRADE DEFLECT TUBING TO PERMIT ENTRY THROUGH BOTTOM OF VALVE BOX. 12" POP-UP SPRAY HEAD WITH CHECK VALVE, CLOSED NOZZLE, & SWING PIPE (ZONE OPERATIONAL INDICATOR)PLANT MATERIAL DRIP FLUSH VALVE 15WITH OPERATIONAL INDICATOR NOTE: INSTALL ASSEMBLY TO REST ON GRAVEL SUMP. CONTAIN ENTIRE ASSEMBLY WITHIN BOX. NO VALVE BOX EXTENSIONS WILL BE ACCEPTED. PROVIDE 3"-4" CLEARANCE BETWEEN TOP OF CONTROL VALVE SOLENOID AND BOTTOM OF VALVE BOX LID. TOP OF VALVE BOX TO BE FLUSH WITH FINISH GRADE. VALVE BOX SHALL NOT REST ON DRIP TUBING. PVC MAINLINE PVC SCH. 40 TEE OR ELL PVC SCH. 80 NIPPLE 3" MIN. DEPTH 3 4" WASHED GRAVEL VALVE SIZE MIPTxINS. PVC ADAPTER JUMBO VALVE BOX - BRAND BOX LID W/ CONTROLLER AND STATION NUMBER - REFER TO TECHNICAL SPECIFICATIONS. WATERPROOF SPLICE 24" COILED WIRE PVC SCH. 80 NIPPLE PVC SCH. 40 ELL FINISH GRADE LINE SIZE PVC BALL VALVE 3" MIN.DRIP VALVE ASSEMBLY (SEE SCHEDULE) STAINLESS STEEL WORM GEAR OR PINCH CLAMP VALVE SIZE POLY PIPING - SWEEP TO SPECIFIED DEPTH 12" POP-UP SPRAY HEAD WITH CHECK VALVE, CLOSED NOZZLE, PURPLE CAP & SWING PIPE (ZONE OPERATIONAL INDICATOR) INSERT TEE WITH CLAMPS DRIP VALVE 1224V - POLY LATERAL PLANT SIZE EMITTER FLOW RATE EMITTER QTY. AT MULCHED BED LOCATIONS - SINGLE HYDROZONE EMITTER QTY. AT MULCHED BED LOCATIONS - MIXED HYDROZONE 1 - 2 GALLON MATERIAL 0.5 GPH ONE EACH VERY LOW - ONE EACH, LOW - ONE EACH, MODERATE - TWO EACH 5 GALLON MATERIAL 0.5 GPH TWO EACH VERY LOW - ONE EACH, LOW - TWO EACH, MODERATE - THREE EACH 112" CALIPER TREE 1.0 GPH THREE EACH VERY LOW - TWO EACH, LOW - THREE EACH, MODERATE - FIVE EACH 2" CALIPER TREE 1.0 GPH FOUR EACH VERY LOW - THREE EACH, LOW - FOUR EACH, MODERATE - SIX EACH 212" CALIPER TREE 1.0 GPH SIX EACH VERY LOW - FOUR EACH, LOW - SIX EACH, MODERATE - EIGHT EACH 3" CALIPER TREE 1.0 GPH EIGHT EACH VERY LOW - SIX EACH, LOW - EIGHT EACH, MODERATE - SIX 2.0 GPH 312" CALIPER TREE 1.0 GPH NINE EACH VERY LOW - SEVEN EACH, LOW - NINE EACH, MODERATE - SEVEN 2.0 GPH 4" CALIPER TREE 1.0 GPH TEN EACH VERY LOW - EIGHT EACH, LOW - TEN EACH, MODERATE - EIGHT 2.0 GPH 6 FT. CONIFEROUS TREE 1.0 GPH FOUR EACH VERY LOW - THREE EACH, LOW - FOUR EACH, MODERATE - SIX EACH 8 FT. CONIFEROUS TREE 1.0 GPH SIX EACH VERY LOW - FOUR EACH, LOW - SIX EACH, MODERATE - EIGHT EACH 10 FT. CONIFEROUS TREE 1.0 GPH EIGHT EACH VERY LOW - SIX EACH, LOW - EIGHT EACH, MODERATE - SIX 2.0 GPH 12 FT. CONIFEROUS TREE 1.0 GPH TEN EACH VERY LOW - EIGHT EACH, LOW - TEN EACH, MODERATE - EIGHT 2.0 GPH NOTES: ·INSTALL EMITTERS ON OPPOSING SIDES OF ROOTBALL. THREE OR MORE EMITTERS SHALL BE EQUALLY SPACED AROUND ROOT BALL. ·EMITTERS ARE TO BE INSTALLED TO CLEAR SURFACE BY A MINIMUM OF 1" AND A MAXIMUM OF 2". ·FLUSH ALL LINES THOROUGHLY, INCLUDING EMITTER MICRO-TUBING PRIOR TO EMITTER INSTALLATION. ·IF PLANTING ON A 4:1 SLOPE OR STEEPER, INSTALL BOTH EMITTERS ON UPHILL SIDE OF ROOT BALL. ·EMITTERS SHALL BE SELF-FLUSHING, PRESSURE COMPENSATING-TYPE UNLESS NOTED OTHERWISE WITHIN TECHNICAL SPECIFICATIONS. ·DRIP VALVE ZONES ARE DESIGNED TO ACCOUNT FOR DIFFERENCES IN PLANT REQUIREMENTS (HYDROZONES) AND SUN EXPOSURE. ·CONTRACTOR SHALL ENSURE HYDROZONES ARE VALVED SEPARATELY AS SHOWN ON PLAN. ·SITE CONDITIONS MAY DICTATE THAT MULTIPLE SUN EXPOSURES ARE VALVED TOGETHER DURING THE DESIGN PROCESS. CONTRACTOR SHALL ADJUST EMITTER SCHEDULE AS FOLLOWS: ··EMITTER QUANTITIES SHALL REMAIN THE SAME BUT EMITTER GALLONAGES SHALL BE DOUBLED FOR PLANTS WITH SOUTH AND WEST EXPOSURES. ··EMITTER QUANTITIES AND GALLONAGE SHALL BE AS SHOWN IN SCHEDULE FOR PLANTS WITH NORTH AND EAST EXPOSURES. ··PLANTINGS WITH NORTH AND EAST EXPOSURE SHALL DICTATE VALVE RUN-TIMES AND CONTRACTOR SHALL ADJUST SCHEDULING ACCORDINGLY. DOWN 4:1(+)-SLOPE SECTION 10" MIN 4"-6" PLANTING BACKFILL MATERIAL POLY DRIP TUBING PLANT ROOTBALL EMITTER - STAKE TO EDGE OF ROOTBALL EMITTER MICRO-TUBING - 60" MAXIMUM LENGTH PLANT MATERIAL EMITTER - REFER TO SCHEDULE FOR EMITTER QUANTITY. REFER TO SPECIFICATIONS FOR MANUFACTURER AND MODEL NUMBER. MULCH LAYER EMITTER MICRO-TUBING POLY DRIP TUBING - RE: TECHNICAL SPECIFICATIONS 6" 10 GAUGE JUTE STAKE OR APPROVED EQUAL PLAN DRIP EMITTER SHRUB BEDS NOTE: APPLY TEFLON TAPE TO ALL MALE THREADED FITTINGS AND THREADED NIPPLES. SCH. 80 PVC NIPPLE - LENGTH AS REQUIRED 3 4" CRUSHED GRAVEL SUMP - FILL BOX TO BOTTOM OF VALVE BODY PVC BALL VALVE - FIPTxFIPT SCH.3 4" FIPTxFIPT ELL WITH 3 4"x2" NIPPLE 6" ROUND VALVE BOX. BRAND LID WITH "BV" REFER TO TECHNICAL SPECIFICATIONS. CENTER BOX OVER ASSEMBLY SCH.80 PVC NIPPLE - LENGTH AS REQUIRED 3 4" FIPT x 12" INSERT x 1 2" INSERT TEE (17 MM TUBING COMPATIBLE) FINISH GRADE LINE SIZE SLIP x 3 4'' FIPT TEE 2''-4'' 16EMITTER TUBING CONNECTION with PVC and VALVE BOX (TURF ZONE) DRIPLINE START CONNECTION MALE ADAPTER PERIMETER LATERALS 2'' TO 4'' FROM EDGE LF REMOTE CONTROL VALVE WITH DISC FILTER AND PRV SUPPLY HEADER - POLY OR PVC DRIPLINE TUBING LATERAL AREA PERIMETER EXHAUST HEADER - POLY OR PVC PLUMBED TO PVC OR POLY LINE FLUSHING VALVE - REFER TO DETAIL. 14SUBSURFACE DRIP - TOP VIEW END FEED LAYOUT - TURF ZONE ONLY DIRECTORY IRRIGATION SCHEDULE IR-1.0 IRRIGATION NOTES IR-1.0 IRRIGATION PLAN IR-1.1 IRRIGATION DETAILS IR-2.0 IRRIGATION DETAILS IR-2.1 AND CHART R Know what's below. Call before you dig. CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. 13 860 Tabor Street, Suite 200 Lakewood, Colorado 80401 o: 303.980.5327 www.hydrosystemskdi.com Irrigation Consulting & Water Management 03/01/2021