HomeMy WebLinkAboutFile Documents.210 S West End St.0011-2021-BCHO (12)IR-1.0
job - 0189
drawn - TB
21
0
S
W
E
S
T
E
N
D
S
T
R
E
E
T
AS
P
E
N
,
C
O
L
O
R
A
D
O
piñon sage
landscape architects
700 redstone ave
carbondale, CO, 81623
devin@pinonsage.com
(970) 379.0816
IRRIGATION
NOTES AND
SCHEDULE
issue date - 01/27/21
revisions
description#dateDIRECTORY
IRRIGATION SCHEDULE IR-1.0
IRRIGATION NOTES IR-1.0
IRRIGATION PLAN IR-1.1
IRRIGATION DETAILS IR-2.0
IRRIGATION DETAILS IR-2.1
AND CHART
R
Know what's below.
Call before you
dig.
CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
1.DRAWINGS AND BASE INFORMATION ALL BASE AND PLANTING INFORMATION HAVE BEEN PROVIDED BY PINION SAGE. THE CONTRACTOR IS RESPONSIBLE
TO NOTIFY HYDROSYSTEMS*KDI OF ANY DISCREPANCIES BETWEEN THE UTILITY OR PLANTING PLANS AND THE IRRIGATION PLAN. IF CONTRACTOR FAILS
TO NOTIFY HYDROSYSTEMS*KDI AND MAKES CHANGES TO THE IRRIGATION SYSTEM DESIGN, HE ASSUMES ALL COSTS AND LIABILITIES ASSOCIATED WITH
THOSE FIELD CHANGES. REFER TO SPECIFICATIONS FOR ADDITIONAL PROJECT REQUIREMENTS. CONTACT IRRIGATION CONSULTANT FOR CURRENT
SPECIFICATIONS IF NOT PROVIDED.
2.SYSTEM PRESSURE - CITY OF ASPEN FIRE PROTECTION DISTRICT HAS INDICATED THAT THE STATIC WATER PRESSURE IN THIS AREA SHOULD BE 94 PSI MIN AT
THE CITY MAIN IN THE STREET. THE CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY PRESSURE PRIOR TO COMMENCING ANY CONSTRUCTION AND NOTIFY
HYDROSYSTEMS*KDI OF ANY VARIANCE FROM THE STATED PRESSURE IMMEDIATELY. WRITTEN DOCUMENTATION OF PRESSURE TEST AND RESULTS SHALL
BE PROVIDED TO HYDROSYSTEMS*KDI AT CONSTRUCTION ONSET. IF CONTRACTOR FAILS TO FIELD VERIFY PRESSURE AND/OR NOTIFY
HYDROSYSTEMS*KDI OR ANY VARIATIONS FROM THIS PRESSURE, THEN HE ASSUMES ALL CONSTRUCTION AND ENGINEERING COSTS ASSOCIATED WITH
SYSTEM MODIFICATIONS REQUIRED TO ACCOMMODATE ACTUAL SITE PRESSURE. THIS SYSTEM HAS BEEN DESIGNED FOR A REQUIRED STATIC PRESSURE
OF 70 PSI MINIMUM AT THE POINT OF CONNECTION.
3.IRRIGATION SYSTEM OPERATION INTENT - THIS IRRIGATION SYSTEM HAS BEEN DESIGNED TO IRRIGATE THE ESTABLISHED LANDSCAPE WITHIN A THREE NIGHT PER
WEEK, SIX HOUR PER NIGHT WATERING WINDOW. ESTABLISHMENT WATERING WILL REQUIRE UP TO TWICE AS MUCH IRRIGATION FOR A FOUR TO SIX WEEK
PERIOD. THE DESIGN IS BASED ON THE FOLLOWING PROJECTED WEEKLY APPLICATION RATES AFTER ESTABLISHMENT. THESE FIGURES ARE BASED ON A
30-YEAR AVERAGE WEATHER DATA AND WILL NEED TO BE ADJUSTED DUE TO SEASONAL CHANGES AND WEATHER CONDITIONS ABOVE AND BELOW THE
AVERAGE VALUES UTILIZED.
FESCUE 1.72" PER WEEK PEAK SEASON
ORNAMENTAL PLANTINGS 0.78" PER WEEK PEAK SEASON
4.EQUIPMENT INSTALLATION - ALL IRRIGATION EQUIPMENT MUST BE INSTALLED WITHIN PROPERTY LIMITS AND WITHIN LANDSCAPED AREAS. ANY EQUIPMENT
OTHER THAN VALVE BOXES OR SLEEVING THAT CONTAINS PIPE OR WIRES SHOWN OUTSIDE OF THESE LIMITS IS SHOWN IN THAT LOCATION FOR GRAPHICAL
CLARITY ONLY. ALL VALVE BOXES SHALL BE INSTALLED A MINIMUM OF 2'-0" FROM EDGE OF ANY PAVED SURFACES UNLESS SPECIFICALLY INDICATED ON
PLANS. BOXES INSTALLED IN OPEN TURF AREAS SHALL BE KEPT TO EDGES AND STAKED FOR REVIEW IF ALONG HIGH TRAFFIC AREAS. ALL VALVE BOXES
SHALL BE PLACED A MINIMUM OF 3'-0" FROM THE CENTERLINE OF ANY DRAINAGE SWALE. ALL VALVE BOXES WITHIN PAVEMENT SHALL BE TIER 15 RATED
BOXES FOR HEAVY DUTY NON-DELIBERATE TRAFFIC. BOX LID COLOR SHALL MATCH ADJACENT MATERIALS, I.E. GREEN IN TURF, TAN IN WOOD MULCH,
GRAY IN STONE MULCH, PURPLE FOR RECLAIMED WATER SYSTEMS (IF REQUIRED). REFER TO LANDSCAPE PLANS FOR MATERIAL COLORS AND TYPES.
ALL BOXES SHALL BE INSTALLED TO BE FLUSH WITH GRADE AND IN AN ORDERLY MANNER.
5.PIPING INSTALLATION - IRRIGATION PIPING SHALL MAINTAIN A MINIMUM DISTANCE FROM BUILDING FOUNDATIONS OF 5 FEET OR AS DESCRIBED IN SOILS
REPORT, WHICHEVER IS GREATER. NO SPRAY IRRIGATION SHALL OCCUR WITHIN 5 FEET OF THE FOUNDATION. NO DRIP IRRIGATION SHALL OCCUR WITHIN 5
FEET OF THE FOUNDATION UNLESS SOIL MOISTURE SENSORS ARE INSTALLED ON VALVES SERVICING THESE AREAS. MAINLINE AND LATERAL PIPING SHALL
STAY OUT OF DRIPLINES OF TREES OR HAVE WRITTEN CONSENT OF THE CITY FORESTER.
6.MANUAL DRAIN VALVES - CONTRACTOR TO INSTALL ONE MANUAL DRAIN VALVE ON PRESSURE SUPPLY LINE DIRECTLY DOWNSTREAM OF BACKFLOW
PREVENTER AND AT ALL LOW POINTS AND DEAD ENDS OF PRESSURE SUPPLY PIPING TO ENSURE COMPLETE DRAINAGE OF SYSTEM. CONTRACTOR SHALL
BE RESPONSIBLE FOR DETERMINING THESE LOCATIONS IN-FIELD AND INSTALLATION LOCATIONS SHALL BE NOTED ON AS-BUILTS. FOR INTERIOR MOUNTED
BACKFLOW PREVENTER LOCATIONS, INSTALL ONE BOILER DRAIN VALVE DOWNSTREAM OF BACKFLOW PREVENTER.
7.POP-UP SPRAY NOZZLES - CONTRACTOR TO INSTALL PLASTIC NOZZLES ON ALL POP-UP SPRAY HEADS. INSTALL 15 U-SERIES NOZZLES ON ALL HEADS SPACED
AT 12' TO 14'. INSTALL 12 U-SERIES NOZZLES ON ALL HEADS SPACED 10' TO 11'. INSTALL 10 SERIES NOZZLES ON ALL HEADS SPACED AT 8' TO 9'. INSTALL 8
SERIES NOZZLES ON ALL HEADS SPACED AT 6' TO 7'. INSTALL 5' NOZZLES ON ALL HEADS SPACED AT 5'. INSTALL SIDE STRIP NOZZLES ON ALL HEADS WITH
AN "S" DESIGNATION AND RIGHT AND LEFT CORNER STRIP NOZZLES ON ALL HEADS WITH AN "L" OR "R" DESIGNATION. VARIABLE ARC NOZZLES SHOULD
BE UTILIZED ADJACENT TO CURVILINEAR SHRUB BEDS OR FOR ANY ANGLES THAT ARE NOT A STANDARD NOZZLE ANGLE. WHERE INDICATED, INSTALL LOW
FLOW SQ SERIES SQUARE NOZZLES AT SPACING SHOWN.
8.DRIP IRRIGATION - REFER TO IRRIGATION DETAIL SHEET FOR DRIP EMITTER QUANTITIES AND DRIP TUBING FLOW AND PLACEMENT.
9.UNLABELED PIPING - ALL UNLABELED LATERAL PIPING SHALL BE 1" MINIMUM UNLESS OTHERWISE NOTED.
10.SLEEVING - ALL SLEEVING UNDER PAVED SURFACES SHOWN ON PLANS IS BY CONTRACTOR UNLESS OTHERWISE NOTED. SLEEVING SHALL BE INSTALLED IN
THE SIZES AND QUANTITIES SHOWN ON PLANS OR BASED ON THE SCHEDULE BELOW. WHERE SLEEVES ARE SHOWN, BUT NOT LABELED, FOLLOW THE
SCHEDULE BELOW. ALL MAINLINE, CONTROL WIRES AND DRIP LINES UNDER PAVED SURFACES ARE TO BE INSTALLED IN SLEEVING. ALL MAINLINE SLEEVE
LOCATIONS TO INCLUDE A SEPARATE WIRE SLEEVE.
SLEEVED PIPE SIZE/WIRE QUANTITY REQUIRED SLEEVE SIZE & (QUANTITY)
3 4" - 11 4" PIPING 2" PVC (1)
1-25 CONTROL WIRES 2" PVC (1)
11.SPARE CONTROL WIRES - CONTRACTOR SHALL EXTEND THREE SPARE WIRES (ONE COMMON AND 2 CONTROL WIRES) FROM EACH CONTROLLER TO THE END
OF THE MAINLINE SERVING THAT CONTROLLER OR AS SHOWN ON THE PLANS. INSTALL SPARE WIRES IN 10" ROUND VALVE BOX WITH QUICK COUPLING
VALVE. REFER TO SPECIFICATIONS FOR WIRE COLOR. SEE IRRIGATION SCHEDULE FOR ADDITIONAL INFORMATION.
12.ADJUSTMENT - CONTRACTOR SHALL FINE TUNE/ADJUST THE IRRIGATION SYSTEM TO REDUCE/AVOID OVERSPRAY ONTO HARD SURFACES BY ADJUSTING
NOZZLE DIRECTION AND NOZZLE RADIUS.
13.PLANS AND SPECIFICATIONS - CONTRACTOR RESPONSIBLE TO ENSURE WORK CONFORMS TO PLANS AND SPECIFICATIONS. AT ONSET OF CONSTRUCTION,
VERIFY PLANS ARE CURRENT. WHERE REQUIRED BY CITY OR TOWN, CONTRACTOR SHALL CONSTRUCT ONLY OFF CITY OR TOWN STAMPED PLANS.
REVISIONS TO CITY OR TOWN STAMPED PLANS SHALL CONFORM TO CITY OR TOWN FIELD CHANGE PROCEDURES AND DOCUMENTATION.
14.WATER BUDGETS AND PROJECTIONS - HYDROSYSTEMS-KDI HAS BASED THE IRRIGATION DESIGN AND THE ASSOCIATED PROJECTED WATER USE UPON SUCH
FACTORS AS CITY OR WATER DISTRICT IMPOSED REQUIREMENTS, PUBLISHED PLANT SPECIES WATER NEEDS, SELECTED IRRIGATION METHOD EFFICIENCIES
AS REPORTED BY INDEPENDENT TESTING FACILITIES, HISTORICAL WEATHER DATA FOR THE PROJECT LOCATION, AND PROPER MAINTENANCE
PROCEDURES. HYDROSYSTEMS*KDI IS NOT RESPONSIBLE, AND ACCEPTS NO RESPONSIBILITY, FOR THE ACTUAL WATER USAGE VARIATION THAT IS A
RESULT OF FIELD MODIFICATIONS TO THE SYSTEM NOT MATCHING CONSTRUCTION DOCUMENTS, IMPROPER MAINTENANCE, WASTE DUE TO SYSTEM
DAMAGE OR VANDALISM, OR WEATHER CONDITIONS THAT DEVIATE FROM PUBLISHED 30 YEAR HISTORICAL AVERAGES.
13.ASPEN WATER EFFICIENT IRRIGATION DESIGNER STATEMENT - I HAVE COMPLIED WITH THE CRITERIA OF THE WATER EFFICIENT LANDSCAPING STANDARDS AND
APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE IRRIGATION DESIGN PLAN.
14.IRRIGATION WITHIN ROW - CONTRACTOR IS RESPONSIBLE TO ENSURE THAT ANY IRRIGATION WITHIN THE ROW AREA (BETWEEN STREET AND THE PROPERTY
LINE) IS TO BE ON SEPARATE CONTROL VALVES THAN THOSE WITHIN THE PROPERTY LINE.
15.IRRIGATION AND EXISTING TREES - ALL IRRIGATION WORK PERFORMED WITHIN THE DRIP LINE OF EXISTING TREES REQUIRES HAND GRUBBING NO DEEPER THAN
SIX INCHES (6") AND MUST BE AS FAR FROM TREE TRUNK AS PRACTICALLY POSSIBLE. DO NOT CUT ROOTS 2'' AND GREATER IN DIAMETER WITHOUT THE
EXPRESS WRITTEN CONSENT OF FORESTER.
16.ALL DISTURBANCES WITHIN DRIPLINES OF EXISTING TREES SHALL BE REVIEWED BY THE CITY FORESTER.
IRRIGATION SCHEDULE
SYMBOL MANUFACTURER MODEL NO.DESCRIPTION DETAIL NO.
RAIN BIRD RD-06-S-P30 WITH MPR- SERIES
NOZZLE POP-UP SPRAY HEAD 8
RAIN BIRD/HUNTER RD-06-S-P40 WITH HUNTER ROTATOR
M1000 NOZZLES POP-UP ROTATOR SPRAY HEAD 8
RAIN BIRD PEB-PRS-D ELECTRIC CONTROL VALVE 7
RAIN BIRD 44-LRC QUICK COUPLING VALVE 5
HUNTER I-CORE-M - 16 STATION MODEL ELECTRIC CONTROLLER 2
HUNTER SOLAR SYNC - WSS-SEN WEATHER SENSOR DEVICE 3
FEBCO 860U RP BACKFLOW PREVENTER 1
N/S OLDCASTLE / CARSON REFER TO SPECIFICATIONS AND DETAILS VALVE BOXES VARIOUS
N/S MATCO 201X MANUAL DRAIN VALVE 6
LINE SIZE - 21 2'' AND SMALLER GATE VALVE 4
RAIN BIRD PESB-PRS MASTER CONTROL VALVE 1
DATA INDUSTRIAL IR250B (1")FLOW SENSOR 1
SCHEDULE 40 PVC PVC MAINLINE 10
TYPE K COPPER HARD COPPER PIPE 1
#100 NSF POLY LATERAL 10
SCHEDULE 40 PVC PVC SLEEVING 11
RAIN BIRD XCZ-PRB-COM DRIP VALVE ASSEMBLY 12
TORO BLUE STRIPE POLY DRIP TUBING -3 4" MIN. WIDTH 13
DRIP LINE BLOW-OUT STUB 15
N/S RAIN BIRD XERI-BUG DRIP EMITTERS 13
NETAFIM
TLHCVXR5-1201 ROWS SPACED 12" MIN,
SPACED EVENLY AT SHRUB BEDS AND
18'' ROWS FOR HATCH LABELED EXISTING
SHADE GROUND COVERS
SUBSURFACE IN-LINE DRIP PIPE 14 & 16
NETAFIM TL075FTEE DRIPPERLINE CONNECTION 14 & 16
BUILDING PENETRATION - THROUGH A
NIBCO T585-70-SV (1'')LOCKABLE BALL VALVE 9
#1
#1
#1
#1
A
W
FS
GPM CONTROL VALVE SIZE
CONTROLLER & STATION NO.
A (controller)NUMBER OF SPARE WIRES - 2 CONTROL AND 1 SPARE
WIRES TO WHICH CONTROLLER - SEE CONSTRUCTION NOTES3
IRRIGATION CONSTRUCTION NOTES
860 Tabor Street, Suite 200 Lakewood, Colorado 80401
o: 303.980.5327 www.hydrosystemskdi.com
Irrigation Consulting & Water Management
CONSTRUCTION
DRAWING
03/01/2021
U
P
ADU
GARAGE
MASTER
AR
dr 1''
A14
dr 1''
A13
dr 1''
A12
dr 1''
A11
8 1''
A5
dr 1''
A7
3 1''
A4
dr 1''
A2
dr 1''
A1
(1)2''
(1)2''
(3)2''
(2)2''
(3)2''
dr 1''
A10
(1)2''
FS
#1
#1
#1#1
#1
#1
#1
#1
#1#1
#1
dr 1''
A9
dr 1''
A8
(2)2''
dr 1''
A31''
1''
1''
1''1''
1''
1''
2 1''
A6
(1)2''
IR-1.1
0'5'10'20'
Scale: 1"=20'-0"
N
job - 0189
drawn - TB
21
0
S
W
E
S
T
E
N
D
S
T
R
E
E
T
AS
P
E
N
,
C
O
L
O
R
A
D
O
piñon sage
landscape architects
700 redstone ave
carbondale, CO, 81623
devin@pinonsage.com
(970) 379.0816
IRRIGATION
PLAN
issue date - 01/27/21
revisions
description#date
Xref .\Xrefs\20-0421\z\LIFT-630WHA-LCD-SHEET SETUP_2020-04-22 - Standard\LIFT-630WHA-X-TBLOCK.dwg
DIRECTORY
IRRIGATION SCHEDULE IR-1.0
IRRIGATION NOTES IR-1.0
IRRIGATION PLAN IR-1.1
IRRIGATION DETAILS IR-2.0
IRRIGATION DETAILS IR-2.1
AND CHART
R
Know what's below.
Call before you
dig.
CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
A CONTROLLER LOCATION "A"
WALL MOUNT ONE CONTROLLER (REFER TO SCHEDULE FOR MODEL & STATION COUNT), AT
INDICATED LOCATION. COORDINATE A 120 VOLT POWER CIRCUIT WITH ELECTRICAL CONTRACTOR
FROM RESIDENCE. ELECTRICAL WIRE/CONDUIT POWER CONNECTION TO CONTROLLER IS BY
CONTRACTOR WITH WORK CONFORMING TO LOCAL CODES. EXTEND PE89 SHIELDED CABLE FROM
THE FLOW SENSOR AND 4 #14 UFUL WIRES (TWO BLUE AND TWO ORANGE) FROM MASTER VALVE TO
ASSOCIATED CONTROLLER. CONNECT WIRES TO THE APPROPRIATE SENSOR INPUT PORTS. FEES
AND PERMITS ASSOCIATED WITH WORK ARE TO BE OBTAINED AND PAID BY CONTRACTOR. FINAL
CONTROLLER LOCATION SHALL BE APPROVED BY OWNER PRIOR TO INSTALLATION. MOUNT ONE
WEATHER SENSOR ON BUILDING WHERE THERE IS 20 FT. OF CLEARANCE FROM ANY OVERHANG OR
OBSTRUCTING FEATURE. FINAL WEATHER SENSOR LOCATION SHALL BE APPROVED BY OWNER
PRIOR TO INSTALLATION.
A
ANY DISTURBANCE UNDER EXISTING TREES WILL REQUIRE
REVIEW AND APPROVAL OF CITY FORESTER PRIOR TO
CONSTRUCTION. HAND GRUBBING ONLY UNDER EXISTING
TREES. NO HEAVY EQUIPMENT ALLOWED.
POINT OF CONNECTION #1 - 3/4"
PEAK FLOW REQUIREMENT: 10 GPM. REQUIRED STATIC PRESSURE: 94 PSI MIN.
TIE ONTO COPPER STUB WITH LOCKABLE ISOLATION VALVE THIS APPROXIMATE LOCATION AND EXTEND
PVC MAINLINE AS SHOWN. COORDINATE WITH PLUMBING CONTRACTOR. ASSURE IRRIGATION
CONNECTION IS MADE AFTER METER AND PRIOR TO ANY PRESSURE REDUCING VALVES AND BACKFLOW
PREVENTERS FOR HOUSE. INSTALL ONE 3/4'' REDUCED PRESSURE BACKFLOW PREVENTER WITH AIR
GAP PLUMBED TO DRAIN PER MANUFACTURER'S RECOMMENDATIONS, ONE BOILER DRAIN VALVE, ONE 1"
FLOW SENSOR, ONE 1" MASTER VALVE, ONE ISOLATION VALVE AND EXTEND 1" COPPER LATERAL TO
BUILDING EXTERIOR. EXTEND ONE PE89 SHIELDED CABLE FROM FLOW SENSOR TO DATA RETRIEVAL
UNIT LOCATED IN ASSOCIATED CONTROLLER. EXTEND 4 UFUL14# WIRE (TWO ORANGE AND TWO BLUE)
AND CONNECT 2 OF THE WIRES FROM THE MASTER VALVE TO THE DATA RETRIEVAL BOARD IN
ASSOCIATED CONTROLLER. SEE DETAIL SHEET FOR REQUIRED PIPE LENGTHS UPSTREAM AND
DOWNSTREAM OF FLOW SENSING UNIT. WORK SHALL CONFORM TO LOCAL CODE. FEES AND PERMITS
ASSOCIATED WITH WORK ARE TO BE OBTAINED AND PAID FOR BY CONTRACTOR. FINAL BACKFLOW
PREVENTER LOCATION SHALL BE APPROVED BY OWNER PRIOR TO INSTALLATION.
1
1
860 Tabor Street, Suite 200 Lakewood, Colorado 80401
o: 303.980.5327 www.hydrosystemskdi.com
Irrigation Consulting & Water Management
DRIP ZONE A12 REQUIRES 12'' SWING
PIPE SUPPLY IN A 1'' COPPER RISER
SLEEVE TO RAISED PLANTER.
COORDINATE WITH LANDSCAPE
ARCHITECT,
TOWN OF ASPEN REQUIRED
ACCESSIBLE LOCKABLE IRRIGATION
BALL BALL VALVE LOCATION.
CONSTRUCTION
DRAWING
LOCATE AND TIE ONTO EXISTING
IRRIGATION LATERAL SUPPLYING THE
EXISTING TREE LAWN IRRIGATION AT
THIS APPROXIMATE LOCATION.
CONTROLLER WIRE SLEEVE FOR
MASTER VALVE, FLOW SENSOR AND
CONTROL WIRES AS NEEDED.
03/01/2021
It appears that the
graphic scale is correct
and drawing is at
1"=10'. Revise.
This ROW area appears to
be landscaped with turf,
perennials and a tree.
Please include species and
irrigation on all plans and
calculations.
AS per WELS Section
5.2.3 turf areas less
than 10 feet in any
dimension shall not be
overhead irrigated.
Revise to subsurface
irrigation for turf.
Allow generous
mulched tree rings to
reduce impacts to tree
roots.
WELS Section 5.2.7
requires separate
irrigation valves for
trees. Revise plans
accordingly.
IR-2.0
job - 0189
drawn - TB
21
0
S
W
E
S
T
E
N
D
S
T
R
E
E
T
AS
P
E
N
,
C
O
L
O
R
A
D
O
piñon sage
landscape architects
700 redstone ave
carbondale, CO, 81623
devin@pinonsage.com
(970) 379.0816
IRRIGATION
DETAILS
issue date - 01/27/21
revisions
description#date
R
Know what's below.
Call before you
dig.
CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
NOTE: DIAMETERS OF BALL VALVES, PVC FITTINGS AND NIPPLES SHALL
EQUAL ELECTRIC CONTROL VALVE DIAMETER. VALVE BOXES SHALL BE
INSTALLED PARALLEL OR PERPENDICULAR TO ADJACENT SIDEWALKS AND
HARD SURFACES WHERE APPLICABLE. APPLY TEFLON TAPE TO ALL MALE
THREADED FITTINGS AND THREADED NIPPLES.
RECTANGULAR VALVE BOX. BRAND LID
WITH CONTROLLER & STATION #. REFER
TO TECHNICAL SPECIFICATIONS. CENTER
BOX OVER ASSEMBLY.
PROVIDE 12" CONTINUOUS COILS OF ALL
"MAINTENANCE" SPARE CONTROL/COMMON
WIRING WITHIN VALVE BOX
PVC BALL VALVE - FIPTxFIPT
3 4" CRUSHED GRAVEL SUMP - FILL BOX
TO BOTTOM OF VALVE BODY
SCH. 80 PVC NIPPLE - LENGTH AS
REQUIRED
SERVICE TEE - SOLVENT WELD
OR GASKETED FITTING - REFER
TO SPECIFICATIONS
CONTROL WIRE BUNDLE
POLY LATERAL - SWEEP TO SPECIFIED DEPTH
STAINLESS STEEL CLAMP - INSTALL TWO
CLAMPS ON 112" & 2" DIA. FITTINGS
PVC MIPTxINSERT ADAPTER
ELECTRIC CONTROL VALVE
4"
FINISH GRADE
7ELECTRIC CONTROL VALVE
24V - Poly Lateral
FINISH GRADE
APPLY TEFLON TAPE TO ALL MALE THREADED
PVC FITTINGS AND ALL NIPPLES
3 4" CRUSHED GRAVEL SUMP 1 CU. FT.
2" VALVE MARKER
10" ROUND VALVE BOX - BRAND THE
LETTER "D' IN LID. REFER TO
TECHNICAL SPECIFICATIONS.
2" CL 160 PVC ACCESS SLEEVE -
LENGTH AS REQUIRED
3 4" FxF SCH. 80 PVC 90 ELL (2)
3 4"xCL PVC NIPPLE SCH. 80 (2)
3 4"x6" SCH. 80 GALVANIZED STEEL NIPPLE
3 4" BRASS GLOBE VALVE
3 4" MxF SCH. 40 PVC 90 ELL
SOIL BLANKET COVERING SUMP
3 4"x4" PVC NIPPLE SCH. 80
3 4" CRUSHED GRAVEL SUMP. SEE
TECHNICAL SPECIFICATIONS FOR
SUMP SIZE
PVC PRESSURE MAINLINE
MANUAL DRAIN VALVE 6
ADJUSTABLE LENGTH
MOUNTING ARM
SECURE BRACKET TO EAVE PER
MANUFACTURER'S RECOMMENDATIONS.
BUILDING EAVE
NOTE: MOUNT SENSOR RECEIVER PER
CONTROLLER DETAIL.
SOLAR SYNC SENSOR - TOP OF
SENSOR TO BE ABOVE GUTTER
AND/OR ANY OBSTRUCTIONS
WEATHER SENSOR 3EAVE MOUNTED - SolarSync
FINISH GRADE
2"
3"
10" ROUND VALVE BOX. BRAND "GV"
ON LID OF VALVE BOX. REFER TO
TECHNICAL SPECIFICATIONS.
GATE VALVE W/ CROSS HANDLE AND
SOLID WEDGE DISC.
3 4" CRUSHED GRAVEL SUMP - FILL
BOX TO WITHIN 2" OF TOP OF 6"
PVC ACCESS SLEEVE∅
6" CLASS 160 PVC SLEEVE BOTTOM TO
BE NOTCHED AND CONTACT TOP OF
PRESSURE MAINLINE
PVC PRESSURE MAINLINE
SCH. 40 PVC MALE ADAPTER (2) - SIZE
TO EQUAL GATE VALVE DIAMETER
UNDISTURBED SOIL
GATE VALVE 4
3"
2"
10" ROUND VALVE BOX BRAND
"QC" INTO VALVE BOX LID.
REFER TO TECHNICAL
SPECIFICATIONS.
3 4" CRUSHED GRAVEL SUMP -
FILL BOX TO WITHIN 2" OF
BOTTOM OF QCV LID
1" BRASS NIPPLE LENGTH AS REQUIRED
LINE SIZE BRASS COUPLING
1 2"x12" REBAR STABILIZING STAKE
TYPICAL TWO SIDES PER QUICK
COUPLING VALVE LOCATION
LASCO #G 13S-212 UNITIZED SWING
JOINT W/ BRASS INSERT STABILIZER
ELBOW. PROVIDE WITH 1" MIPT INLET
PRESSURE MAINLINEx1" PVC SERVICE TEE -
SOLVENT WELD OR GASKETED FITTING REFER
TO SPECIFICAIONS
QUICK COUPLING VALVE
FINISH GRADE
APPLY TEFLON TAPE TO ALL THREADED NIPPLES
QUICK COUPLING VALVE 5
2'' TYPE ''L'' RIGID COPPER TUBING
SECURE BACKFLOW PREVENTER ASSEMBLY
FASTEN TUBING TO FINISH FLOOR @ 18'' 0.C.
AND COPPER TUBING TO WALL VIA UNI-STRUT
CHANNEL AND COPPER FASTENERS AT 6 FT. O.C.
VENT BACKFLOW PREVENTER DRAIN INTO
POINT OF CONNECTION - INTERIOR
FINISH FLOOR
FLOOR DRAIN
FEBCO 860U REDUCED PRESSURE BACKFLOW
PRESSURE REDUCING VALVE (AS REQUIRED, RE:PLAN)
PREVENTER WITH INTEGRAL UNIONS
FLOW
FEBCO 601 AIR GAP DRAIN
CxM ADAPTER - LINE DIA. (FOUR REQ'D.)
12'' MIN.
CxCxF TEE
FLOW SENSOR
3/4'' I.P. MALE BRASS BOILER DRAIN
W/ WHEEL HANDLE
BALL VALVE FOR SHUT-OFF
TYPE K HARD COPPER TO PENETRATION LOCATIONS
WIRE CONDUIT FROM CONTROLLER
LINE SIZE MASTER VALVE
TYPE ''K'' RIGID COPPER - CONNECT TO BUILDING
COLD WATER SERVICE LINE DOWNSTREAM OF
WATER METER, UPSTREAM OF ANY PRESSURE
REDUCING VALVES OR OTHER BUILDING SERVICE
EQUIPMENT
NOTE: REFER TO TECHNICAL
SPECIFICATIONS FOR MINIMUM
TRENCH WIDTHS.FINISH
GRADE
ROTOR LATERAL
PIPING
BACKFILL MATERIAL (TYP.)
4-6" BODIES: 14"
12" BODIES: 18"
MAINLINE
4-6" BODIES: 18"
12" BODIES: 24"
CONTROL WIRE BUNDLE OR TWO
WIRE COMMUNICATION CABLE (PER
SPECIFICATIONS)
24"
SPRAY HEAD LATERAL
PIPING OR DRIP LINE
HEADER.
1024"TYPICAL
TRENCH
B
A
ROUGH GRADE
C
NOTE:
·ALL SLEEVE MATERIAL PER IRRIGATION SCHEDULE, SIZE AS NOTED ON
PLAN.
·INSTALL SLEEVES IN SIDE-BY-SIDE CONFIGURATION WHERE MULTIPLE
SLEEVES ARE TO BE INSTALLED. SPACE SLEEVES 4" TO 6" APART. DO
NOT STACK SLEEVES VERTICALLY.
·CONTRACTOR TO COORDINATE WITH FLATWORK INSTALLER TO BRAND A
"V" IN SIDEWALK OR CURB AT BOTH ENDS OF SLEEVE CROSSING.
·SLEEVING THROUGH OR UNDER RETAINING WALLS, PLANTER WALLS, POND
LINING, OR WATER QUALITY AREAS SHALL BE COORDINATED WITH CIVIL
WORK AT APPROXIMATE LOCATIONS SHOWN.
PAVED SURFACE
CURB AND GUTTER
(IF APPLICABLE)
2" PVC PIPE SLEEVE MARKER -
INSTALL AT BOTH ENDS OF EACH
SLEEVE LOCATION AND EXTEND AT
LEAST 3' ABOVE GRADE. SPRAY
EXPOSED PORTION OF MARKER WITH
GREEN FLUORESCENT PAINT. REMOVE
AT FINAL INSTALL.
SEAL ENDS OF SLEEVE WITH
CLOTH DUCT TAPE (TYPICAL)
PVC SLEEVING (TYPICAL)
IRRIGATION SLEEVING
24" MIN.
12" MIN.
36" MIN.
11
PVC CONDUIT W/ SWEEP ELL (TYP. UNDERGROUND
LOCATIONS) - 2 EACH LOCATION - ONE 2" PVC SCH
40 DIRECT BURIAL CONDUIT STUB-OUT FOR 24V
VALVE CONTROL WIRING AND ONE 3 4" PVC CONDUIT
FOR 120V POWER SUPPLY IN DIRECT BURIAL
CONDUIT AS PER CITY CODE.
FINISH GRADE
EMT MALE ADAPTER & PVC FEMALE ADAPTER
SECURE CONDUIT TO WALL 18" O.C.
EMT CONDUIT - SIZE TO ACCOMMODATE
CONTROL WIRE QUANTITY
EMT MALE ADAPTER W/ WASHER & LOCK RING
ELECTRIC CONTROLLER
SECURE CONTROLLER TO
WALL WITH ANCHOR BOLTS
18''
54" MIN.
60" MAX.
ELECTRIC CONTROLLER 2EXTERIOR WALL MOUNT
LOCKABLE BALL VALVE
FINISH GRADE
3"-4"
BRASS BALL VALVE - PVC x MIP
ADAPTERS (2 EACH) DIAMETER TO
EQUAL PIPE DIAMETER
3 4" CRUSHED GRAVEL SUMP - 1 CU. FT.
6" CLASS 160 PVC SLEEVE. BOTTOM
TO BE NOTCHED AND CONTACT TOP OF
PRESSURE MAINLINE
PVC PRESSURE MAINLINE OR LATERAL
10" ROUND VALVE BOX - BRAND "BV"
ON LID OF VALVE BOX. REFER TO
TECHNICAL SPECIFICATIONS.
PAD LOCK
9
3"
SET BOTTOM OF CAP AT GRADE
CURB & GUTTER, SIDEWALK OR
HARD SURFACE WHERE
APPLICABLE
POP-UP SPRAY HEAD
12" MALExBARB ELL
12" DIA. POLYETHYLENE SWING
PIPE (4 L.F. MAXIMUM LENGTH)
12" MALExBARB ADAPTER
POLY LATERAL PIPING W/ LINE SIZEx\"
INSERTxFIPT FITTING AND CLAMPS
NOTE:
·SET HEAD PERPENDICULAR TO FINISH GRADE.
·APPLY TEFLON TAPE TO MALE PVC THREADED FITTINGS.
·DOUBLE CLAMP 11 2" & 2" DIAMETER FITTINGS.
POP-UP SPRAY HEAD 8SWING PIPE - POLY
1
CONSTRUCTION
DRAWING
03/01/2021
IR-2.1
job - 0189
drawn - TB
21
0
S
W
E
S
T
E
N
D
S
T
R
E
E
T
AS
P
E
N
,
C
O
L
O
R
A
D
O
CONSTRUCTION
DRAWING
piñon sage
landscape architects
700 redstone ave
carbondale, CO, 81623
devin@pinonsage.com
(970) 379.0816
IRRIGATION
DETAILS
issue date - 01/27/21
revisions
description#date
3 4" PVC BALL VALVE WITH 3 4" PVC
INSxMIPT ADAPTER AND S.S. CLAMP
3 4" DRIP TUBING - COIL SUFFICIENT
LENGTH IN BOX TO EXTEND HOSE
ADAPTER OUTSIDE OF VALVE BOX.
3 4" WASHED RIVER ROCK SUMP (1
CU. FT.)
INSERT TEE WITH CLAMPS
10" ROUND VALVE BOX WITH COVER
- BRAND "DB" INTO VALVE BOX LID.
REFER TO TECHNICAL
SPECIFICATIONS.
SECTIONPLAN
DISTANCES VARY: CONTRACTOR SHALL
LOCATE FLUSH VALVE BOX TO BE
SCREENED BY PLANT MATERIAL AND
ACCESSIBLE. OPERATIONAL INDICATOR
SHALL BE LOCATED FOR EASY
VISIBILITY DURING OPERATION
PLANT MATERIAL
INDICATOR HEAD
PLANTER BED
WALL OR EDGER
FLUSH VALVE
POLY PIPE FROM
EXHAUST HEADER
OR DRIP LATERAL
FINISH GRADE
DEFLECT TUBING TO PERMIT
ENTRY THROUGH BOTTOM OF
VALVE BOX.
12" POP-UP SPRAY HEAD WITH
CHECK VALVE, CLOSED NOZZLE, &
SWING PIPE (ZONE OPERATIONAL
INDICATOR)PLANT MATERIAL
DRIP FLUSH VALVE 15WITH OPERATIONAL INDICATOR
NOTE:
INSTALL ASSEMBLY TO REST ON GRAVEL SUMP. CONTAIN ENTIRE ASSEMBLY WITHIN BOX. NO VALVE
BOX EXTENSIONS WILL BE ACCEPTED. PROVIDE 3"-4" CLEARANCE BETWEEN TOP OF CONTROL
VALVE SOLENOID AND BOTTOM OF VALVE BOX LID. TOP OF VALVE BOX TO BE FLUSH WITH FINISH
GRADE. VALVE BOX SHALL NOT REST ON DRIP TUBING.
PVC MAINLINE
PVC SCH. 40 TEE OR ELL
PVC SCH. 80 NIPPLE 3" MIN. DEPTH 3 4" WASHED GRAVEL
VALVE SIZE MIPTxINS. PVC ADAPTER
JUMBO VALVE BOX - BRAND BOX LID W/
CONTROLLER AND STATION NUMBER -
REFER TO TECHNICAL SPECIFICATIONS.
WATERPROOF SPLICE
24" COILED WIRE
PVC SCH. 80 NIPPLE
PVC SCH. 40 ELL
FINISH GRADE
LINE SIZE PVC BALL VALVE
3" MIN.DRIP VALVE ASSEMBLY (SEE
SCHEDULE)
STAINLESS STEEL WORM GEAR OR
PINCH CLAMP
VALVE SIZE POLY PIPING -
SWEEP TO SPECIFIED DEPTH
12" POP-UP SPRAY HEAD WITH CHECK
VALVE, CLOSED NOZZLE, PURPLE CAP &
SWING PIPE (ZONE OPERATIONAL
INDICATOR)
INSERT TEE WITH CLAMPS
DRIP VALVE 1224V - POLY LATERAL
PLANT SIZE EMITTER
FLOW RATE
EMITTER QTY. AT MULCHED
BED LOCATIONS - SINGLE
HYDROZONE
EMITTER QTY. AT MULCHED BED
LOCATIONS - MIXED HYDROZONE
1 - 2 GALLON MATERIAL 0.5 GPH ONE EACH VERY LOW - ONE EACH, LOW - ONE EACH,
MODERATE - TWO EACH
5 GALLON MATERIAL 0.5 GPH TWO EACH VERY LOW - ONE EACH, LOW - TWO EACH,
MODERATE - THREE EACH
112" CALIPER TREE 1.0 GPH THREE EACH VERY LOW - TWO EACH, LOW - THREE EACH,
MODERATE - FIVE EACH
2" CALIPER TREE 1.0 GPH FOUR EACH VERY LOW - THREE EACH, LOW - FOUR EACH,
MODERATE - SIX EACH
212" CALIPER TREE 1.0 GPH SIX EACH VERY LOW - FOUR EACH, LOW - SIX EACH,
MODERATE - EIGHT EACH
3" CALIPER TREE 1.0 GPH EIGHT EACH VERY LOW - SIX EACH, LOW - EIGHT EACH,
MODERATE - SIX 2.0 GPH
312" CALIPER TREE 1.0 GPH NINE EACH VERY LOW - SEVEN EACH, LOW - NINE EACH,
MODERATE - SEVEN 2.0 GPH
4" CALIPER TREE 1.0 GPH TEN EACH VERY LOW - EIGHT EACH, LOW - TEN EACH,
MODERATE - EIGHT 2.0 GPH
6 FT. CONIFEROUS TREE 1.0 GPH FOUR EACH VERY LOW - THREE EACH, LOW - FOUR EACH,
MODERATE - SIX EACH
8 FT. CONIFEROUS TREE 1.0 GPH SIX EACH VERY LOW - FOUR EACH, LOW - SIX EACH,
MODERATE - EIGHT EACH
10 FT. CONIFEROUS TREE 1.0 GPH EIGHT EACH VERY LOW - SIX EACH, LOW - EIGHT EACH,
MODERATE - SIX 2.0 GPH
12 FT. CONIFEROUS TREE 1.0 GPH TEN EACH VERY LOW - EIGHT EACH, LOW - TEN EACH,
MODERATE - EIGHT 2.0 GPH
NOTES:
·INSTALL EMITTERS ON OPPOSING SIDES OF ROOTBALL. THREE OR MORE EMITTERS
SHALL BE EQUALLY SPACED AROUND ROOT BALL.
·EMITTERS ARE TO BE INSTALLED TO CLEAR SURFACE BY A MINIMUM OF 1" AND A
MAXIMUM OF 2".
·FLUSH ALL LINES THOROUGHLY, INCLUDING EMITTER MICRO-TUBING PRIOR TO
EMITTER INSTALLATION.
·IF PLANTING ON A 4:1 SLOPE OR STEEPER, INSTALL BOTH EMITTERS ON UPHILL SIDE
OF ROOT BALL.
·EMITTERS SHALL BE SELF-FLUSHING, PRESSURE COMPENSATING-TYPE UNLESS
NOTED OTHERWISE WITHIN TECHNICAL SPECIFICATIONS.
·DRIP VALVE ZONES ARE DESIGNED TO ACCOUNT FOR DIFFERENCES IN PLANT
REQUIREMENTS (HYDROZONES) AND SUN EXPOSURE.
·CONTRACTOR SHALL ENSURE HYDROZONES ARE VALVED SEPARATELY AS SHOWN
ON PLAN.
·SITE CONDITIONS MAY DICTATE THAT MULTIPLE SUN EXPOSURES ARE VALVED
TOGETHER DURING THE DESIGN PROCESS. CONTRACTOR SHALL ADJUST EMITTER
SCHEDULE AS FOLLOWS:
··EMITTER QUANTITIES SHALL REMAIN THE SAME BUT EMITTER GALLONAGES SHALL
BE DOUBLED FOR PLANTS WITH SOUTH AND WEST EXPOSURES.
··EMITTER QUANTITIES AND GALLONAGE SHALL BE AS SHOWN IN SCHEDULE FOR
PLANTS WITH NORTH AND EAST EXPOSURES.
··PLANTINGS WITH NORTH AND EAST EXPOSURE SHALL DICTATE VALVE RUN-TIMES
AND CONTRACTOR SHALL ADJUST SCHEDULING ACCORDINGLY.
DOWN
4:1(+)-SLOPE
SECTION
10" MIN
4"-6"
PLANTING BACKFILL MATERIAL
POLY DRIP TUBING
PLANT ROOTBALL
EMITTER - STAKE TO EDGE OF
ROOTBALL
EMITTER MICRO-TUBING - 60"
MAXIMUM LENGTH
PLANT MATERIAL
EMITTER - REFER TO SCHEDULE FOR
EMITTER QUANTITY. REFER TO
SPECIFICATIONS FOR MANUFACTURER
AND MODEL NUMBER.
MULCH LAYER
EMITTER MICRO-TUBING
POLY DRIP TUBING - RE:
TECHNICAL SPECIFICATIONS
6" 10 GAUGE JUTE STAKE OR
APPROVED EQUAL
PLAN
DRIP EMITTER
SHRUB BEDS
NOTE: APPLY TEFLON TAPE TO
ALL MALE THREADED FITTINGS
AND THREADED NIPPLES.
SCH. 80 PVC NIPPLE - LENGTH AS REQUIRED
3 4" CRUSHED GRAVEL SUMP - FILL
BOX TO BOTTOM OF VALVE BODY
PVC BALL VALVE - FIPTxFIPT
SCH.3 4" FIPTxFIPT ELL WITH 3 4"x2" NIPPLE
6" ROUND VALVE BOX. BRAND LID WITH "BV"
REFER TO TECHNICAL SPECIFICATIONS.
CENTER BOX OVER ASSEMBLY
SCH.80 PVC NIPPLE - LENGTH AS REQUIRED
3 4" FIPT x 12" INSERT x 1 2" INSERT TEE
(17 MM TUBING COMPATIBLE)
FINISH GRADE
LINE SIZE SLIP x 3 4'' FIPT TEE
2''-4''
16EMITTER TUBING CONNECTION
with PVC and VALVE BOX (TURF ZONE)
DRIPLINE START
CONNECTION MALE ADAPTER
PERIMETER LATERALS 2'' TO 4'' FROM EDGE
LF
REMOTE CONTROL VALVE
WITH DISC FILTER AND PRV
SUPPLY HEADER - POLY OR PVC
DRIPLINE TUBING LATERAL
AREA PERIMETER
EXHAUST HEADER - POLY OR PVC
PLUMBED TO PVC OR POLY LINE
FLUSHING VALVE - REFER TO DETAIL.
14SUBSURFACE DRIP - TOP VIEW
END FEED LAYOUT - TURF ZONE ONLY
DIRECTORY
IRRIGATION SCHEDULE IR-1.0
IRRIGATION NOTES IR-1.0
IRRIGATION PLAN IR-1.1
IRRIGATION DETAILS IR-2.0
IRRIGATION DETAILS IR-2.1
AND CHART
R
Know what's below.
Call before you
dig.
CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
13
860 Tabor Street, Suite 200 Lakewood, Colorado 80401
o: 303.980.5327 www.hydrosystemskdi.com
Irrigation Consulting & Water Management
03/01/2021