Loading...
HomeMy WebLinkAboutFile Documents.150 Roaring Fork Dr.0010-2019-BCHO (21)A-001X EXISTING SITE PLAN SHEET NUMBER SHEET TITLE Mo r r i s R e s i d e n c e 15 0 Ro a r i n g F o r k D r i v e As p e n , CO 81 6 1 1 Red Room Design 1001 Grand Avenue, Ste 211Glenwood Springs, CO 81601970.413.3144 DRAWING ISSUE 5/3/2019 1:03 PMPERMIT SET 12/5/2019 6:24 AMREVISION #1 03/26/2020 1:26 PMPHASE I CD INT ELEVS REVISION #1 COMMENTS 04/30/2020 12:00 PM NOTE: GREY BACKGROUND DENOTES EXISTING SURVEY. PROJECT 100' = 8095'-9"FLOOR ELEVATIONS WINE CELLAR - T.O. CONC = 82'-4 3/8" VIF (8078'-1 3/8") LOWER LEVEL - T.O. CONC = 91'-3 7/8" VIF (8087'-7/8") MAIN LEVEL - T.O. PLY = 100'-0" (8095'-9") UPPER LEVEL - T.O. PLY = 109'-0" VIF (8104'-9") LOFT LEVEL T.O. PLY =111'-5 3/8" (8107'-2 3/8") 8090' 6' 5' 10 ' 6' 5' 5' 6' 5' 30 ' Dash Line = Face of Building at Grade Retaining Wall Subdivision Setback Water Meter Gas Meter Electric Meter Property Line Utility Easement Pro p e r t y L i n e Uti l i t y E a s m e n t Property Line Utility Easeme n t Utility Easeme n t Setback Line Utility Easement Uti l i t y E a s e m e n t Setback Line Se t b a c k L i n e Entry Asphalt Parking Asphalt Driveway Edge of Pave m e n t Roaring Fork D r i v e Deck DeckDeck Edge of Pavement Eastwood Drive 8080 8095 1 Existing Site Plan 1" = 10' 05/05/2020 05/11/2020 tonyf Z-014 DECK MAINTENANCE SHEET NUMBER SHEET TITLE Mo r r i s R e s i d e n c e 15 0 Ro a r i n g F o r k D r i v e As p e n , CO 81 6 1 1 Red Room Design 1001 Grand Avenue, Ste 211Glenwood Springs, CO 81601970.413.3144 DRAWING ISSUE 5/3/2019 1:03 PMPERMIT SET 12/5/2019 6:24 AMREVISION #1 NOT FOR CONSTRUCTION 03/26/2020 1:26 PMPHASE I CD INT ELEVS REVISION #1 COMMENTS 03/26/2020 1:26 PM 3' - 1 / 2 " 8" 8 3/4" 3' 3" 4" MAX. OPENING DISTANCEPER IRC R312.1.3 METAL GUARDRAILPER IRC R312.1 1 Existing Railing 1 1/2"= 1'-0" 2 Proposed Railing 1 1/2"= 1'-0" 4" MAX. OPENING DISTANCEPER IRC R312.1.3 4" MAX. OPENING DISTANCE PER IRC R312.1.3 HOGWIRE POORLY SECURED W/ FENCING STAPLES. MANY AREASWHERE HOGWIRE FENCING ISUNSECURED FOR AREAS GREATER THAN 4". HOGWIRE POORLY SECURED W/ FENCING STAPLES. MANY AREASWHERE HOGWIRE FENCING ISUNSECURED FOR AREAS GREATER THAN 4". WOOD POSTS HAVE BEEN RE-SECURED WITH NON-ORIGINAL GALVANIZED LAG BOLTS, WHERE ORIGINAL FASTNERS HAVE FAILED TO SECURE POSTS TO DECK STRUCTURE. PLEASE REFERENCE VIDEO SUBMITTED WITH CHANGE ORDER FOR EXAMPLES OF STRUCTURAL COMPROMISE. SIGNIFICANT CRACKING IS EXHIBITED IN POSTS.STABILITY IS COMPROMISED. SIGNIFICANT CRACKING IS EXHIBITED IN POSTS.STABILITY IS COMPROMISED. FAILING RAILING POSTS REINFORCED USING L BRACKETS. THESE BRACKETS ARE NOW ALSO FAILING. WARPING GUARDRAIL DUE TOUSING WOOD NOT SUITED FOREXTERIOR USE. NOTE: RAILING MUST BE REPLACED TO MEET IRC R312 LIFE SAFETY REQUIREMENTS 05/05/2020 Z-015 DECK MAINTENANCE SHEET NUMBER SHEET TITLE Mo r r i s R e s i d e n c e 15 0 Ro a r i n g F o r k D r i v e As p e n , CO 81 6 1 1 Red Room Design 1001 Grand Avenue, Ste 211Glenwood Springs, CO 81601970.413.3144 DRAWING ISSUE 5/3/2019 1:03 PMPERMIT SET 12/5/2019 6:24 AMREVISION #1 NOT FOR CONSTRUCTION 03/26/2020 1:26 PMPHASE I CD INT ELEVS REVISION #1 COMMENTS 03/26/2020 1:26 PM G D C B AFE Existing Site Wall Existing Site WallExisting Site Wall Existing South Elevation 1/8" = 1'-0" MANY OF THE ORIGINAL 2X DECK JOISTS HAVE FAILED AND HAVE BEEN BRACED BY ADDITIONAL 2X JOISTS CANTILEVERED JOISTW/NO SUPPORT EXISTING DECK JOISTS AREWEATHERED AND APPEAR TO BE MOISTURE DAMAGED. REFERENCE LETTER FROM STRUCTUAL ENGINEER. MANY FASTENERS HAVE BEEN ADDED TO THE DECK OFF THEKITCHEN TO HELP PREVENTFURTHER FAILING AS THE DECK HAD BEGUN SEPARATING ITSELF FROM THE HOME INADEQUATE RIM JOISTHOLDING UP TREX DECKING EXISTING DECK JOISTS AREWEATHERED AND MOISTURE DAMAGED REFERENCE LETTER FROM STRUCTUAL ENGINEER 6X6 COLUMN NOT SITTING ON CONCRETE FOOTING/ FOUNDATION, BURIED IN EARTH AND WRAPPED IN PLASTIC. COLUMN IS NOTSTRUCTURALLY FASTENED. REFERENCE LETTER FROM STRUCTURAL ENGINEER 4X6 COLUMN EXCEEDS SLENDERNESS LIMIT REFERENCE LETTER FROMSTRUCTURAL ENGINEER 6X6 COLUMN NOT PROPERLY SITTING ON CONCRETE FOOTING/FOUNDATION 6X6 COLUMN NOT PROPERLY SITTING ON CONCRETE FOOTING/FOUNDATION, COLUMN SHIMMED WITHDAMAGED 2X LUMBER DECK BEAM IS A MULTI-PLY BEAM SHOWING FAILURE IN THE FORM OF CUPPING REFERENCE LETTER FROMSTRUCTURAL ENGINEER. DECK BEAM IS A TWO-PLY MICROLAM BEAM, NOT SUITED FOR EXTERIOR USE REFERENCE LETTER FROMSTRUCTURAL ENGINEER INSUFFICIENT CONNECTIONFOR STABILITY. CONNECTION, COLUMN + BEAM TO BE REPLACED CONNECTION NEEDSTO BE IMPROVED, COLUMN + BEAM TO BE REPLACED DECK BEAM IS A MULTI-PLY BEAM SHOWING FAILURE IN THE FORM OF CUPPING REFERENCE LETTER FROMSTRUCTURAL ENGINEER POOR WATERPROOFING AND DETAILING OF GRATE 2 5 23 11 10 8 576 1 12 9 4 3 1 4 6 7 8910 MANY OF THE ORIGINAL 2X DECK JOISTS HAVE FAILED AND HAVE BEEN BRACED BY ADDITIONAL 2XJOISTS CONNECTION NEEDSTO BE IMPROVED,COLUMN + BEAM NEED TO BE REPLACED 11 12 1314 CONNECTION NEEDS TO BE IMPROVED, COLUMN + BEAM NEED TO BE REPLACED 13 14 05/05/2020