HomeMy WebLinkAboutFile Documents.430 W Hallam St.0291.2017 (51).ARBKREMOTE CONTROL DRIP VALVE ASSEMBLY:RAIN BIRD XCZ-100-PRF
QUICK COUPLING VALVE ASSEMBLY:RAIN BIRD 5RC
LOCKABLE BALL VALVE ASSEMBLY:APOLLO
BACKFLOW PREVENTION ASSEMBLY:WATTS RPZ, 3/4-INCH
UNCONNECTED PIPE CROSSING
ZONE FLOW RATE (GPM)
VALVE SIZE (INCHES)
CONTROLLER AND STATION NUMBER
ZONE PRECIPITATION RATE (IN/HR)
A1
121"
1.4
:
1-INCH SIZE UNLESS OTHERWISE INDICATED
MAINLINE PIPE: CLASS 200 PVC
1 1/4-INCH SIZE UNLESS OTHERWISE INDICATED
POLYETHYLENE DRIP PIPE TO DRIP EMITTERS:
3/4-INCH UNLESS OTHERWISE INDICATED, 30 PSI REQUIRED
UV RADIATION RESISTANT
SLEEVES:CLASS 200 PVC
MASTER VALVE ASSEMBLY:MV RAIN BIRD PESB
FLUSH CAP ASSEMBLY
FLOW SENSOR ASSEMBLY:RAIN BIRD FS100P
RAIN/FREEZE SENSOR: RAIN BIRD WR2-RFC
IRRIGATION LEGEND AND SCHEDULE
IRRIGATION CONTROLLER UNIT WITH:RAIN/FREEZE SENSOR, BUILT IN FLOW
CONTROLLER A: RAIN BIRD ESP-ME3, 11 STATIONS USED
INLINE DRIP TUBING:NETAFIM TLCV9-12
INLINE DRIP TUBING:NETAFIM TLCV9-12
CLASS 200 PVC
FIELD LOCATE 3/4-INCH IRRIGATION STUBOUT DOWNSTREAM OF DOMESTIC WATER METER
AND UPSTREAM OF DOMESTIC BACKFLOW PREVENTER, LOCATED IN BASEMENT MECHANICAL
ROOM. MAKE 3/4-INCH COPPER PIPE CONNECTION AND ROUTE TO BUILDING EXTERIOR AND
INSTALL 3/4-INCH BACKFLOW PREVENTER PER LOCAL CODES AND AS INDICATED ON
INSTALLATION DETAILS. INSTALL LOCKING GATE VALVE PER CITY OF ASPEN WELS CODE,
MASTER VALVE, FLOW SENSOR, ALL 1-INCH SIZE. VERIFY LOCATION OF POC OR EXISTING
BACKFLOW PREVENTER WITH OWNER'S REPRESENTATIVE OR GENERAL CONTRACTOR.
WALL MOUNT THE IRRIGATION CONTROLLER AT THE APPROXIMATE LOCATION SHOWN. VERIFY
LOCATION WITH THE OWNER'S REPRESENTATIVE OR GENERAL CONTRACTOR. FINAL LOCATION
TO BE APPROVED BY OWNER'S REPRESENTATIVE. COORDINATE 120V POWER WITH THE
OWNER'S REPRESENTATIVE OR GENERAL CONTRACTOR. INSTALL WEATHER/RAIN SENSOR IN
PROXIMITY ON CLOSEST BUILDING ROOF LINE AS INDICATED BY SENSOR SYMBOL,
UNOBSTRUCTED FOR 10'IN ALL DIRECTION.
COORDINATE INSTALLATION OF RAIN/FREEZE SENSOR WITH ARCHITECT. INSTALLATION
LOCATION SHALL BE UNOBSTRUCTED FOR 10-FEET IN ALL DIRECTIONS, PREFERABLY THE
BUILDING AT ROOF LINE.
CONSTRUCTION NOTES
1
2
3
WEST
H
A
L
L
A
M
S
T
R
E
E
T
BLOC
K
3
5
A
L
L
E
Y
POC
ADDRESS: 110 N. 2ND STREET
SIZE: 3/4-INCH
PRESSURE: 78 PSI REQUIRED
FLOW: 10 GPM
1
CONTROLLER
120 VAC POWER REQUIRED
2
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
B
B
B
B
A
A1
DR1"
A2
DR1"
A3
DR1"
A4
DR1"
A5
DR1"
A6
DR1"
A7
4.431"
A8
4.421"
A9
DR1"
A10
DR1"
A14
DR1"
A13
DR1"
A12
3.651"
A11
7.281"
MV
Sheet Title:
Sheet Number:
IR - 1.0
WE
L
S
IR
R
I
G
A
T
I
O
N
AS
-
B
U
I
L
T
43
0
H
A
L
L
A
M
S
T
.
LA
N
D
S
C
A
P
E
S
&
B
E
Y
O
N
D
WO
O
D
Y
C
R
E
E
K
,C
O
1
2
3
4
5
6
7
AS
P
E
N
,
C
O
Pr
o
j
e
c
t
:
Lo
c
a
t
i
o
n
:
Cl
i
e
n
t
:
Cl
i
e
n
t
A
d
d
r
e
s
s
:
Designed:
Drafted:
Reviewed:
AS-BUILT Documents Issued:
Revision Title Date
AS-BUILT IRRIGATION
PLAN
2022.06.30
AS-BUILT DRAWINGS ARE PRODUCED FROM INFORMATION
OBTAINED FROM THE IRRIGATION CONTRACTOR, AND AS
OBSERVED BY THE CONSULTANT, ANY DISCREPANCY SHOULD BE
BROUGHT TO THE ATTENTION OF THE CONSULTANT
EWP
EWP
GG
N O R T H
20'10'5'0'
SCALE: 1"=10 '