HomeMy WebLinkAboutFile Documents.802 E Cooper Ave.0088.2019 (30).ARBK0088-2019-ARBK_BuildingComments_1
Page: ARCHITECTURAL DETAILS A.6.01
File Name: 30.Architectural Plans.pdf
Subject: PlanCheck
Author: nickt
Color:
Provide a listed 1 hour fire rated
and STC 50 rated ceiling
assembly. Print the original
listing with full instructions on the
plans. Revise the detail to match
the assembly.
30.Architectural Plans.pdf (6)
Page: ARCHITECTURAL DETAILS A.6.01
File Name: 30.Architectural Plans.pdf
Subject: PlanCheck
Author: nickt
Color:
Where does the typical partition
wall occur? There do not appear
to be any dwelling separation
walls on the 1st floor or
basement.
Page: GENERAL INFORMATION G.1.01
File Name: 30.Architectural Plans.pdf
Subject: PlanCheck
Author: nickt
Color:
Delete the efficient building
code; the City of Aspen does not
have one. Change electric code
to 2017 edition as adopted by
the state.
Page: INTERIOR ELEVATIONS A.8.01
File Name: 30.Architectural Plans.pdf
Subject: Dryer 100sq in
Author: nickt
Color:
Provide 100 square inch opening
for dryer makeup air in closet
(2014 IMC 504.6)
Page: PROPOSED REFLECTED CEILING PLANS A.2.09
File Name: 30.Architectural Plans.pdf
Subject: PlanCheck
Author: nickt
Color:
All penetrations (can lights, bath
fans, etc) of the rated ceiling will
need to be protected per 2015
IBC 714.4. Indicate this on the
plans.
Scale: AS NOTED
ISSUE
SCHEMATIC DESIGN
HOA SUBMITTAL SET
PERMIT SUBMITTAL SET
ARCHITECTURALDETAILS
1" ACTUAL
IF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILLHAVE BEEN ENLARGED ORREDUCED, AFFECTING ALLLABELED SCALES.
ALL DESIGNS, IDEAS ARRANGEMENTSAND PLANS INDICATED BY THESEDRAWINGS AND SPECIFICATIONS ARETHE PROPERTY AND COPYRIGHT OF KIMRAYMOND ARCHITECTURE + INTERIORSAND SHALL NEITHER BE USED ON ANYOTHER WORK NOR BE USED BY ANYOTHER PERSON FOR ANY USEWHATSOEVER WITHOUT WRITTENPERMISSION. WRITTEN DIMENSIONSSHALL TAKE PRECEDENCE OVER SCALEDDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE . ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECTPRIOR TO COMMENCEMENT OF WORK.
DATE
WA
R
K
R
E
S
I
D
E
N
C
E
R
E
M
O
D
E
L
80
2
E
A
S
T
C
O
O
P
E
R
A
V
E
N
U
E
,
U
N
I
T
1
AS
P
E
N
,
C
O
8
1
6
1
1
3/6/19
3/14/19
4/5/19
2x WOOD STUD, RE: FLOOR PLANS
BATT INSULATION
5/8" GYPSUM WALL BOARD
W/ GWB
ED
EDGE OF WOODDOOR JAMB (±3/16"PROUD OF GWB)
SLAB DOOR OFFSET TOSWINGING SIDE
1 1/4" SLAB DOOR, SEEDOOR SCHEDULEFOR SPECIES & FINISH
FINISH FLOOR (VARIES),SEE INTERIOR ELEVATIONS
1 1/4" WOODDOOR JAMB
TYPICAL 6" TALL BASE-BOARD, SEE INTERIORELEVATIONS FORMATERIAL
FINISH FLOOR(VARIES), SEEINT. ELEVATIONS
DOOR JAMB ARE BOTH3/16" PROUD OF GWB
WOOD DOOR STOP,FINISH TO MATCH JAMB& DOOR
INTERIOR INTERIOR
ELEVATION SECTION
SLABDOOR
DOOR ±3/16" ABOVEFINISH FLOOR
GWB
G SIDE
GWB
HEDULE
UNIT ABOVE
UNIT 1
EXISTING GWB CEILING TOREMAIN
ASSUMED FLOOR ASSEMBLY
COMMERCIAL ACOUSTICSFLOOR BLOKKER™, SEE SPECS
NEW GWB, PAINT TBD
BATT INSULATION
NEW 5/8" GYPSUM WALL BOARD,PAINT (COLOR TBD)
2x4 STUD
1/2" AIR SPACE
BATT INSULATION
NEW COMMERCIAL ACOUSTICS WALLBLOKKER PRO™ SOUND MAT
NOTE: THIS IS AN ASSUMPTION OFASSEMBLY, DETAIL WILL BE UPDATEDAFTER IN-FIELD VERIFICATION
SCALE: 3" = 1'-0"
6 TYPICAL INTERIOR DOOR SILL
A.6.01 SCALE: 3" = 1'-0"
5 TYPICAL CELING ASSEMBLY
A.6.01
Provide a listed 1 hour
fire rated and STC 50rated ceilingassembly. Print theoriginal listing with fullinstructions on theplans. Revise thedetail to match theassembly.
INTERIOR
5/8" GYPSUM WALLBOARD
WOOD BASE TO BE FLUSH W/ GWB
WOOD BASEBOARD, FINISHEDTO MATCH PROPOSED FLOOR
INTERIOR
WOOD
DOOR SCHEDULEFOR SPECIES & FINISH
FINISH FLOOR (VARIES),SEE INTERIOR ELEVATIONS
TYPICAL 6" TALL BASE-BOARD, SEE INTERIORELEVATIONS FORMATERIAL
FINISH FLOOR(VARIES), SEEINT. ELEVATIONS
DOOR ±3/16" ABOVEFINISH FLOOR
EDGE OF WOOD DOOR JAMB(±3/16" PROUD OF GWB)
DASHED LINE INDICATES EDGE OF GWBBEHIND WOOD DOOR JAMB
1 1/4" SLAB DOOR, SEE DOOR SCHEDULEFOR SPECIES & FINISH
INTERIOR UNIT 1
BATT INSULATION
NEW 5/8" GYPSUM WALL BOARD,PAINT (COLOR TBD)
2x4 STUD
1/2" AIR SPACE
BATT INSULATION
2x4 STUD
5/8" GYPSUM WALL BOARD
NEW COMMERCIAL ACOUSTICS WALLBLOKKER PRO™ SOUND MAT
INTERIOR INTERIOR
NOTE: THIS IS AN ASSUMPTION OFASSEMBLY, DETAIL WILL BE UPDATEDAFTER IN-FIELD VERIFICATION
SCALE: 3" = 1'-0"
1 TYPICAL INTERIOR WALL
A.6.01
ASEBOARD DETAILS
SCALE: 3" = 1'-0"
6 TYPICAL INTERIOR DOOR SILL
A.6.01
NTERIOR DOOR HEADER
SCALE: 3" = 1'-0"
5 TYPICAL CELING ASSEMBLY
A.6.01
SCALE: 3" = 1'-0"
2 TYPICAL PARTITION WALL
A.6.01
Where does the
typical partition wall
occur? There do not
appear to be any
dwelling separation
walls on the 1st floor
or basement.
LEGAL DESCRIPTIO
PARCEL ID N
ZO
LO
BLD
OCC. G
CONS
CLIMATE
FIRE SPRI
LAND USE CAT
TOW
SE
ALL CODES REFERENCED ARE TO BE USED AS
AMENDED BY THE STATE OF COLORADO AND
LOCAL JURISDICTION.
-2015 INTERNATIONAL RESIDENTIAL CODE
-2015 INTERNATION MECHANICAL CODE
-2015 INTERNATIONAL PLUMBING CODE
-2015 INTERNATIONAL FUEL & GAS CODE
-2015 IECC (INTERNATIONAL ENERGY CONSERVATION CODE)
- CITY OF ASPEN EFFICIENT BUILDING CODE
-2014 NATIONAL ELECTRICAL CODE
DETAIL
INTERIOR ELEVATION MARKERER
SPOT ELEVATION
DOOR MARK
WINDOW MARK
ROOM NAME AND NUMBER
Delete the efficient
building code; the City
of Aspen does not
have one. Change
electric code to 2017
edition as adopted by
the state.
NC
E
R
E
M
O
D
E
L
ER
A
V
E
N
U
E
,
U
N
I
T
1
CO
8
1
6
1
1
ALL DESIGNS, IDEAS ARRANGEMENTSAND PLANS INDICATED BY THESEDRAWINGS AND SPECIFICATIONS ARETHE PROPERTY AND COPYRIGHT OF KIMRAYMOND ARCHITECTURE + INTERIORSAND SHALL NEITHER BE USED ON ANYOTHER WORK NOR BE USED BY ANYOTHER PERSON FOR ANY USEWHATSOEVER WITHOUT WRITTENPERMISSION. WRITTEN DIMENSIONSSHALL TAKE PRECEDENCE OVER SCALEDDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE . ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECTPRIOR TO COMMENCEMENT OF WORK.
4'-2"V.I.F.
2'-10"
2 (NORTH)1 (WEST)
WASHER
DRYER
WASHER
DRYER
10"
10'-8 1/4"V.I.F.
SCALE: 1/2" = 1'-0"2 LAUNDRY ROOM
Provide 100 square
inch opening for dryer
makeup air in closet
(2014 IMC 504.6)
All penetrations (can lights, bath
fans, etc) of the rated ceiling will
need to be protected per 2015 IBC
714.4. Indicate this on the plans.
Page: SCHEDULES A.7.01
File Name: 30.Architectural Plans.pdf
Subject: PlanCheck
Author: nickt
Color:
New windows and exterior doors
require a U factor of no more
than 0.28. Note this requirement
on the plans. 2015 IECC
402.1.2.
Page: 1
File Name: CoverSheet.pdf
Subject: Snapshot
Author: nickt
Color:
CoverSheet.pdf (1)
New windows and exterior doors require a U factor of no more
than 0.28. Note this requirement on the plans. 2015 IECC
402.1.2.
04/24/2019