HomeMy WebLinkAboutFile Documents.232 E Main St.0132.2018 (88).ACBK0132-2018-ACBK_BuildingComments_3 Subject: PlanCheck Page: G-005 WALL TYPES Page Index: 6 Author: nickt Color: File Name: Architectural Plan Set.232 E Main.2019.11.pdf Indicate the type of rigid insulation to achieve the comcheck R value of 22.8. Do the same for all roof assemblies Indicate the R21 cavity insulation from the comcheck. Architectural Plan Set.232 E Main.2019.11.pdf (11) Subject: PlanCheck Page: G-005 WALL TYPES Page Index: 6 Author: nickt Color: File Name: Architectural Plan Set.232 E Main.2019.11.pdf UL263 is not a design or assembly, it is a test. It appears that you are trying to reference UL I501. Revise. Subject: PlanCheck Page: G-007 MEANS OF EGRESS PLANS & RATED WALL PLANS Page Index: 8 Author: nickt Color: File Name: Architectural Plan Set.232 E Main.2019.11.pdf To make the stair become an exit enclosure requires it to be protected with 1 hour fire barriers and horizontal assemblies. Thoroughly detail all conditions to demonstrate compliance with the continuity and supporting construction provisions of 2015 IBC 707.5 and 707.5.1. Fire barriers must be continuous to the underside of floor decking and roof decking. All primary structure that supports it must also be 1 hour rated. Structural elements such as joists and beams may not penetrate the fire barrier. Subject: PlanCheck Page: G-007 MEANS OF EGRESS PLANS & RATED WALL PLANS Page Index: 8 Author: nickt Color: File Name: Architectural Plan Set.232 E Main.2019.11.pdf Changing the stairway to be an exit enclosure to alleviate travel distance limitations requires this hallway to be an exit passageway. The trash area and mechanical room may not open into exit passageways because they are not normally occupied spaces. 2015 IBC 1024.5 FLOOR & ROOF ASSEMBLIES: SECOND LEVEL FLOOR 3/4" PLYWOOD 3/8" SOUND MAT3/4" PLYWOOD SECOND LEVEL PLAZA DECK FLOOR 1 5/8" WOOD PAVERSSNOWMELT AIRSPACE/ PEDESTALS WATERPROOFING MEMBRANE1/4" DENSDECK RIGID INSULATION -7" MAX., 1 1/2" MIN.3/4" PLYWOOD GABLE ROOF FIBER-REINFORCED CEMENTITIOUS PANELVERTICAL HAT PROFILE FULLY ADHERED ROOFING MEMBRANE1/4" DENSDECK 4" RIGID INSULATION 1 1/2" 18 GA. METAL DECK WOOD SHINGLE ROOF WOOD SHAKE SHINGLE UNDERLAYMENTMINERAL SURFACED CAP SHEET 3/4" PLYWOOD 4" RIGID INSULATION1 x 6 T/G TYPE F FIRE RATING -2 HR MINIMUM UL SYSTEM -U905 ELEVATOR SHAFT CONCRETE MASONRY UNIT WALL 7-5/8" CONCRETE MASONRY UNIT TYPE 1 TYPE 2 TYPE 3 TYPE 1A 1 1 1 TYPE G FIRE RATING -0.5 HR MINIMUM UL U419 or MEA 81-98-M 4 4 TYPE E3 FIRE RATING -1 HR MINIMUMUL U419 or MEA 81-98-M GYPSUM BOARD -(1) LAYER 5/8" GYPSUM BOARDSTEEL STUD -8" 20 GA. STEEL STUD @ MAX 24" O.C. GYPSUM BOARD -(1) LAYER 5/8" GYPSUM BOARD SOUND INSULATION BETWEEN TENANTS STC: 49 DESIGN STC RATING 1 1 HOUR RATED CEILING (UNDER STAIRS): DESIGN NO. UL263 CELING RATING -1 HOUR 1. PERIMETER CHANNELS/C CHANNELS —USED TO SUPPORT STEEL STUDS ENDS OF WALL STRUCTURE. MIN. 6 IN. DEEP WITH MIN. 2 IN. LEGS ANDFORME MIN. NO. 20 MSG GALV. STEEL (0.0329 IN. THICK BARE METAL THICKNESS). PER CHANNELS ATTACHED TO WALL STRUCTURE WITH FASTENERS SPACED NOT THAN 24 IN. O.C. AT BOTH THE TOP AND BOTTOM OF THE VERTICAL LEG. 1A. HANGER WIRE —NOT SHOWN -IF NECESSARY -MIN. 8 GAUGE STEEL WIRE FROM HOLES PUNCHED IN C-CHANNEL (ITEM 1) AND FASTENED TO SUITABLE ATTACHMENT (HSS 3X3X1/4 IN. OR STEEL MEMBER HAVING EQUAL OR GREAT STIFFNESS). HANGER WIRE SPACED NOMINALLY 24 IN. OC. 2. STEEL STUDS—MIN. 6 IN. WIDE WITH MIN. 1-5/8 IN. LEGS CONTAINING FOLD FLANGES AND FORMED FROM MIN. NO. 20 MSG GALV. STEEL (0.0329 IN. THICK METAL THICKNESS). STUDS TO BE CUT 3/8 IN. TO 5/8 IN. LESS THAN THE CLEAR BETWEEN THE VERTICAL LEGS OF THE PERIMETER CHANNELS. STUDS SPACE 16 IN. O.C. AT EACH END OF THE STUD, THE UN-FACED SIDE SHALL BE SECUR PERIMETER CHANNEL WITH ONE MIN 7/16 IN. LONG PAN-HEAD STEEL SCREW. USED AT EACH END OF THE HORIZONTAL BARRIER TO TERMINATE THE ASSEM THE ADJOINING WALL. THESE END STUDS SHALL BE SECURED TO THE ADJOIN IN THE SAME MANNER AS THE PERIMETER CHANNELS (ITEM1). MAXIMUM UNS LENGTH OF STUDS NOT TO EXCEED 8 FT. 1 IN. 3. STEEL STRAP —MIN 4 IN. WIDE FORMED FROM MIN. NO. 20 MSG GALV. STEE IN. THICK BARE METAL THICKNESS). SECURED PERPENDICULAR TO THE STUD CENTERLINE OF THE SPAN USING TWO 1/2 IN. LONG PAN-HEAD STEEL SCREW TO OVERLAP ONE FULL STUD BAY AT SPLICE LOCATIONS. AS AN ALTERNATE T STEEL STRAP, PERIMETER CHANNELS (ITEM 1) MAY BE SUBSTITUTED AND INS THE SAME MANNER AS THE STEEL STRAPS. IF A CONTINUOUS PIECE IS NOT U ABUTTED LEGS ARE INSTALLED ON EACH SIDE OF THE CENTERLINE OF THES OVERLAP ONE FULL STUD BAY. 4. GYPSUM BOARD*—THREE LAYERS OF NOM. 5/8 IN. THICK GYPSUM BOARD WITH LONG DIMENSION PERPENDICULAR TO THE STEEL STUDS. BASE LAYER WITH END JOINTS IN ADJACENT ROWS STAGGERED MIN. 32 IN. BOARDS SECU 1 5 / 8 " VA R I E S 1/4 " 7" M A X . 3/4 " Indicate the type of rigid insulation to achieve the comcheck R value of 22.8. Do the same for all roof assemblies Indicate the R21 cavity insulation from the comcheck. 1 1 HOUR RATED CEILING (UNDER STAIRS): DESIGN NO. UL263 CELING RATING -1 HOUR 1. PERIMETER CHANNELS/C CHANNELS —USED TO SUPPORT STEEL STUDS AT BOTH ENDS OF WALL STRUCTURE. MIN. 6 IN. DEEP WITH MIN. 2 IN. LEGS ANDFORMED FROM MIN. NO. 20 MSG GALV. STEEL (0.0329 IN. THICK BARE METAL THICKNESS). PERIMETER CHANNELS ATTACHED TO WALL STRUCTURE WITH FASTENERS SPACED NOT GREATER THAN 24 IN. O.C. AT BOTH THE TOP AND BOTTOM OF THE VERTICAL LEG. 1A. HANGER WIRE —NOT SHOWN -IF NECESSARY -MIN. 8 GAUGE STEEL WIRE, HUNG FROM HOLES PUNCHED IN C-CHANNEL (ITEM 1) AND FASTENED TO SUITABLE POINT OF ATTACHMENT (HSS 3X3X1/4 IN. OR STEEL MEMBER HAVING EQUAL OR GREATER STIFFNESS). HANGER WIRE SPACED NOMINALLY 24 IN. OC. 2. STEEL STUDS—MIN. 6 IN. WIDE WITH MIN. 1-5/8 IN. LEGS CONTAINING FOLDED BACK FLANGES AND FORMED FROM MIN. NO. 20 MSG GALV. STEEL (0.0329 IN. THICK BARE METAL THICKNESS). STUDS TO BE CUT 3/8 IN. TO 5/8 IN. LESS THAN THE CLEAR SPAN BETWEEN THE VERTICAL LEGS OF THE PERIMETER CHANNELS. STUDS SPACED A MAX. 16 IN. O.C. AT EACH END OF THE STUD, THE UN-FACED SIDE SHALL BE SECURED TO THE PERIMETER CHANNEL WITH ONE MIN 7/16 IN. LONG PAN-HEAD STEEL SCREW. STUDS ARE USED AT EACH END OF THE HORIZONTAL BARRIER TO TERMINATE THE ASSEMBLY AT THE ADJOINING WALL. THESE END STUDS SHALL BE SECURED TO THE ADJOINING WALL IN THE SAME MANNER AS THE PERIMETER CHANNELS (ITEM1). MAXIMUM UNSUPPORTED UL263 is not a design or assembly, it is a test. It appears that you are trying to reference UL I501. Revise. DN 1,380 2,0001,380 2,000 EXIT DISCHARGE LEGEND : CONSTRUCTION TYPE: TYPE V-B , NEW CONSTRUCTION , FULLY SPRINKLERED TOTAL EXTIS : ONE EXIT PER SPACE PROVIDED.ONE EXIT REQUIRED PER TABLE 1006.2.1. OCCUPANCY CLASS: B FULLY SPRINKLERED BUILDING WITH FIRE ALARM STATION TWO STORY BUILDING AREA : 6,111.6 S.F. BUILDING HEIGHT : 13' 0" ESTIMATED TOTAL OCCUPANTS : AREA/ 100 GROSS (PER TABLE 1004.1.2)61.2 = 62 OCCUPANT DOORWAY EXIT WIDTH REQUIRED FOR SPRINKELRED BUILDING 62X.15= 9.3", MIN REQ. = 36" ACTUAL DOORWAY WIDTHS: DOOR #1: (1) @ 36"W = 36" TOTAL DOORWAY WIDTH SUPPLIED = 36" (COMPLIES) STAIRWAY EXIT WIDTH REQUIRED FOR A SPRINKLERED BUILDING:62 x .2 INCHES PER PERSON = 12.4 INCHES REQUIRED. (44" MIN.)ACTUAL WIDTHS: STAIR #1: (1) @ 44"W = 44"TOTAL STAIRWAY WIDTH SUPPLIED = 44" (COMPLIES) MAX LENGTH REQUIRED (EXIT ACCESS TRAVEL W/ SPRINKLERS): 250'-0" MAX LENGTH PROVIDED: 84' 6'' (COMPLIES) HORIZONTAL REQ'D. SEPARATION OF OCCUPANCIES FLOOR OCCUPANCY MAIN SEPARATION N = NO SEPARATION REQUIRED N SECOND LEVEL B B 1 HR FIRE SEPARATION 2 HR FIRE SEPARATION OUTDOOR TERRACE MECH. EQ. SECOND FLOOR TENANT SPACE- 'B' 200 ELEV. 71 ' -5'' T R A V E L D I S T A N C E ROOF LADDER 6 7 8 8.5 9 10 C.2 C.4 E.8 F.8 EXIT 12" A.F.F. 1 1 TWO-WAYCOMMUNICATIONSYSTEM 1 4 EX I T IS T A N C E 5 5 RC I A L To make the stair become an exit enclosure requires it to be protected with 1 hour fire barriers and horizontal assemblies. Thoroughly detail all conditions to demonstrate compliance with the continuity and supporting construction provisions of 2015 IBC 707.5 and 707.5.1. Fire barriers must be continuous to the underside of floor decking and roof decking. All primary structure that supports it must also be 1 hour rated. Structural elements such as joists and beams may not penetrate the fire barrier. UP TENANT SPACE 'B' 101 MECH. RM. 102 ELEV. 44' 0'' TRAVEL DISTANCE 34' 0'' TRAVEL DISTANCE 10' - 0 " 5'-3 " 5 6'-6 5/8" 7 8 8.5 9 10 C.2 C.4 E.8 F.8 6'-0 " EX I T 12" A.F.F. EX I T EGRESSACCESS STAIR 21' 4'' TRAVEL DISTANCE 1 1 TWO-WAY COMMUNICATION SYSTEM1 1 1 TRASH AREA (300 SF) 103 4 4 19' 0'' TRAVEL DISTANCE EGRESS CORR. 104 5 5 E 42" HIGH GUARDRAIL 5 7 8 8.5 9 10 Changing the stairway to be an exit enclosure to alleviate travel distance limitations requires this hallway to be an exit passageway. The trash area and mechanical room may not open into exit passageways because they are not normally occupied spaces. 2015 IBC 1024.5 Subject: PlanCheck Page: A-100 1 PROPOSED MAIN FLOOR PLAN Page Index: 12 Author: nickt Color: File Name: Architectural Plan Set.232 E Main.2019.11.pdf The trash area and mechanical rooms are incidental use areas (2015 IBC 509). It appears you are choosing the fire rated path to protect the rest of the building from them. This requires the walls to be built as fire barriers- fire barriers must be continuous to the underside of the floor/roof decking above and may not be penetrated by any structure. Looking at the current structural plans, this does not appear to comply. Either revise the structure to accommodate the fire barriers or make the trash and mechanical rooms sealed from smoke and fire sprinklered. Subject: PlanCheck Page: A-100 1 PROPOSED MAIN FLOOR PLAN Page Index: 12 Author: nickt Color: File Name: Architectural Plan Set.232 E Main.2019.11.pdf Label the wall types Subject: PlanCheck Page: A-100 1 PROPOSED MAIN FLOOR PLAN Page Index: 12 Author: nickt Color: File Name: Architectural Plan Set.232 E Main.2019.11.pdf Update structural, electric, mechanical, and plumbing sets to match the new proposed stair configuration. Subject: PlanCheck Page: A-212 PROPOSED BUILDING ELEVATIONS Page Index: 16 Author: nickt Color: File Name: Architectural Plan Set.232 E Main.2019.11.pdf Show the 42" guards in elevation Subject: PlanCheck Page: A-400 STAIRS & ELEVATOR Page Index: 22 Author: nickt Color: File Name: Architectural Plan Set.232 E Main.2019.11.pdf UL263 is not a design or assembly, it is a test. It appears that you are trying to reference UL I501. Revise. UP 10 0 ' - 0 " 10 0 ' - 0 " 23'-10 7/8"28'-7 1/2"7'-2 5/8" 85'- 0 " 10' - 0 " 59'-9" TENANT SPACE 'A' 100 1 A-300 2 A-300 TENANT SPACE 'B' 101 3 A-400 1 A-310 2 A-310 5'-3 " 2'-7 3 / 4 " R.O . 10'- 7 3 / 4 " 2'-7 5 / 8 " R.O . 10'- 7 3 / 4 " 2'-7 3 / 4 " R.O . 10 ' - 7 3 / 4 " 2'-7 5 / 8 " R.O . 10' - 7 3 / 4 " 2'-7 1 / 2 " 1'-1 0 1 / 2 " 7'-1 1 7 / 8 " TRASH AREA (300 SF) 103 AIR CURTAIN BY TENANT 12' - 1 1 1 / 2 " TRANSFORMER MECH. RM. 102 ELEV. -2'-0" 9 5/ 8 " 30' - 2 3 / 4 " 7 1 / 4 " 4 7/ 8 " 8'-1 1 / 4 " A-412 1 1 A-311 2 A-311 1 A-600A-5001 A-4001 24'-4"9'-6 3/4"8'-4"9'-2 1/4" 12' - 6 3 / 4 " 4'-0 1 / 8 " 13'- 5 " 13' - 3 " 13 ' - 5 " 3'-1 0 3 / 8 " 4'-1 0 1 / 4 " 4'-9 " 1'-0 5 / 8 " 4 5 6 7 8 8.5 9 10 C.2 C.4 E.8 F.8 D.S.D.S. D.S. FOUNDATIONDRYWELL STORMDRYWELL C-1 E1 E 4'-7 7 / 8 " D.S. D.S. 10'-10 1/4" 23'-7 7/8" 23'-1 5/8" 4 7/8" 4'-7" 4 7/8" 21'-4 1/2" 1'-10" HSS8x8x1/2 HSS8x8x1/2 HSS5x5x1/4 5x5x1/4 ACCESS PANEL ACCESS PANEL 3 A-311 0" 0" -1'-0" * ADA PUSHBUTTON GAS METERS1 F A4 1 A21 C8 1 D 1 D1 D.S. 1 DRAIN TILE, TYP. DRAIN TILE, TYP.1 1 14'-0" M.O. 9'-0" 7 7/8" E BOLLARD, TYP. 9 1 / 4 " 4 7 / 8 " 9'-2 1 / 4 " R.O. 3'-4 " 5 1/ 4 " 1'-4" M.O. 3'-4" ACCESS PANEL -2'-0" B2 1 D24 R K E1 S 4'-7" 4'-4 7 / 8 " 4'-1 3 / 4 " 4'-1 1/2" 3'-11 5/8" 1'-2 7/8"R.O. 3'-4" 2" H I 5'-0 " EGRESS CORR. 104 2" R.O. 3'-4" E 5-2'-0" 5 42" HIGH GUARDRAIL The trash area and mechanical rooms are incidental use areas (2015 IBC 509). It appears you are choosing the fire rated path to protect the rest of the building from them. This requires thewalls to be built as fire barriers- fire barriers must be continuous to the underside of the floor/roof decking above and may not be penetrated by any structure. Looking at the current structuralplans, this does not appear to comply. Either revise the structure to accommodate the fire barriers or make the trash and mechanical rooms sealed from smoke and fire sprinklered. UP 2 A-300 TENANT SPACE 'B' 101 2 A-310 RASH AREA (300 SF) 103 AIR CURTAIN BY TENANT MECH. RM. 102 ELEV. -2'-0" A-400 1 FOUNDATION DRYWELL TORM RYWELL C-1 E1 E 4'- 7 7 / 8 D.S. 23'-1 5/8" 4 7/8" 4'-7" 4 7/8" 21'-4 1/2" HSS5x5x1/4 5x5x1/4 ACCESS PANEL 0" -1'-0" * ADA PUSH BUTTON F C8 DRAIN TILE, TYP. AIN TILE, TYP.1 1 -0" M.O. 9'-0" 7 7/8" E 9 1 / 4 " 4 7 / 8 " 9'- 2 1 / 4 " R.O. 3'- 4 " 5 1 / 4 " ACCESS PANEL -2'-0" D24 R S 4'-7" 4'- 4 7 / 8 " 4'- 1 3 / 4 " 4'-1 1/2" 3'-11 5/8" 1'-2 7/8" R.O. 3'-4" 2" H I 5'- 0 " EGRESS CORR. 104 2" R.O. 3'-4" -2'-0" 5 42" HIGH GUARDRAIL Label the wall types UP 100 ' - 0 " 100 ' - 0 " 23'-10 7/8"28'-7 1/2"7'-2 5/8" 85'- 0 " 10'- 0 " 59'-9" TENANT SPACE 'A' 100 1 A-300 2 A-300 TENANT SPACE 'B' 101 2 A-310 5'-3 " 2'-7 3 / 4 " R.O . 10'- 7 3 / 4 " 2'-7 5 / 8 " R.O . 10 ' - 7 3 / 4 " 2'- 7 3 / 4 " R.O . 10' - 7 3 / 4 " 2'-7 5 / 8 " R.O . 10' - 7 3 / 4 " 7 1 / 2 " TRASH AREA (300 SF) 103 AIR CURTAIN BY TENANT 12'- 1 1 1 / 2 " TRANSFORMER MECH. RM. 102 ELEV. -2'-0" 30 ' - 2 3 / 4 " 7 1 / 4 " 4 7 / 8 " 8'-1 1 / 4 " A-412 1 2 A-311 1 A-600A-5001 A-4001 24'-4"9'-6 3/4"8'-4"9'-2 1/4" 13'- 5 " 13' - 3 " 13'- 5 " 3'-1 0 3 / 8 " 4'-1 0 1 / 4 " 4'-9 " 1'-0 5 / 8 " 5 6 7 8 8.5 9 10 C.2 C.4 E.8 F.8 D.S. FOUNDATION DRYWELL STORM DRYWELL C-1 E1 E 4'-7 7 / 8 " D.S. D.S. 23'-7 7/8" 23'-1 5/8" 4 7/8" 4'-7" 4 7/8" 21'-4 1/2" HSS5x5x1/4 5x5x1/4 ACCESS PANEL 3 A-311 0" -1'-0" * ADA PUSH BUTTON GAS METERS 1 F A4 1 C8 1 D1 D.S. 1 DRAIN TILE, TYP. DRAIN TILE, TYP.1 1 14'-0" M.O. 9'-0" 7 7/8" E BOLLARD, TYP. 9 1 / 4 " 4 7 / 8 " 9'-2 1 / 4 " R.O. 3'-4 " 5 1 / 4 " 1'-4" M.O. 3'-4" ACCESS PANEL -2'-0" D24 R K E1 S 4'-7" 4'-4 7 / 8 " 4'-1 3 / 4 " 4'-1 1/2" 3'-11 5/8" 1'-2 7/8"R.O. 3'-4" 2" H I 5'-0 " EGRESS CORR. 104 2" R.O. 3'-4" E 5 -2'-0" 5 42" HIGH GUARDRAIL 1. PROVIDE F.T. WOOD BLOCKING AT ALL WALL MOUNTED FIXTURES, GRAB BARS, ACCESSORIES AND MILLWORK. 2. FIRE RATED HORIZONTAL AND VERTICAL ASSEMBLIES ARE TO BE CONTINUOUS AND UNINTERRUPTED. 3. ALL EXPOSED STEEL ON THE EXTERIOR OF THE BUILDING IS TO BE PRIMED AND PAINTED. 4. THESE DRAWINGS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF THE ARCHITECTURAL DESIGN CONCEPT. THESE DRAWINGS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FULL COMPLETION OF THE PROJECT. 5. THE CONTRACTOR OR SUBCONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL DIMENSIONS AND CONDITIONS PRIOR TO THE EXECUTION OF ANY WORK AND SHALL NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES. 6. SUBCONTRACTOR SHALL VERIFY ALL PARTITION LAYOUTS WITH THE ARCHITECT BEFORE PROCEEDING WITH FRAMING. 7. ALL WORK SHALL BE COORDINATED WITH ALL OTHER TRADES IN ORDER TO AVOID INTERFERENCES, PRESERVE MAXIMUM HEAD ROOM AND AVOID OMISSIONS. 8. ALL DOORS USED IN CONNECTION WITH EXITS SHALL BE READILY OPENABLE WITHOUT THE USE OF A KEY FROM THE SIDE FROM WHICH EGRESS IS MADE. 9. DIMENSIONS MARKED 'HOLD' ARE CRITICAL AND MUST BE ADHERED TO. WALL DIMENSIONS ARE FACE TO FACE OF FINISHED WALL. 10. DIMENSIONS, TARGETS, ETC. THAT ARE TYPICAL FOR MANY AREAS ARE NOTED ONLY ONCE. 11. PROVIDE PRIME COAT ONLY BEHIND AREAS TO BE COVERED WITH MILLWORK, FILE CABINETS, WALL COVERINGS, PANELS, ETC., TYPICAL UNLESS NOTED OTHERWISE. 12. PROVIDE MOISTURE RESISTANT GYPSUM BOARD AT HIGH MOISTURE AND/OR WET AREAS (IE., SINKS, TOILETS, SHOWERS, ETC.) 13. PROVIDE TILE BACKER CEMENT BOARD AS REQUIRED AT ALL TILE/STONE WET AREA APPLICATION (IE.,SINKS, TOILETS, SHOWERS, ETC.) 14. INTERSECTION BETWEEN UNLIKE MATERIALS ARE TO BE SEALED WITH PAINTABLE CAULK U.N.O. 15. UPON INSTALLATION OF DOOR FRAMES, FILL AND/OR CAULK ANY/ALL GAPS, HOLES, VOIDS, ETC. BETWEEN DOOR FRAME AND WALL SYSTEM, TYPICAL. CAULK TO BE PAINTABLE. 16. THRESHOLDS BE CONTINUOUS FROM JAMB TO JAMB AND/OR WALL TO WALL. 17. THRESHOLD END CONDITIONS TO BE TIGHTLY CUT/SCRIBED TO MATCH SHAPE/PROFILE OF JAMB/WALL WITHOUT ANY GAPS, HOLES, VOIDS, ETC. 18. DO NOT SCALE DRAWINGS. DIMENSIONS SHALL NOT BE CHANGED WITHOUT THE ARCHITECT'S WRITTEN APPROVAL. 19. ALL INTERIOR FINISHES TO COMPLY WITH IBC 2015 TABLE 803.11. 22. EXPOSED CONCRETE WORK IN PUBLIC AREA TO RECEIVE CLEAR CONCRETE SEALER IF NOT INTENDED TO BE PAINTED. 23. G.C. TO CONFIRM/ COORDINATE ELEVATOR SHAFTS/ ROUGH OPENINGS BEFORE COMENCING CONSTRUCTION. 25. 0'-0" = 7903.20' GENERAL NOTES: 1 1 1 Update structural, electric, mechanical, and plumbing sets to match the new proposed stair configuration. A' 7903.20 THIS WALL ABUTS HISTORIC CORTINA LODGE CEDAR SHAKE SHINGLES OVER GABLED ROOF, ROOF AT (9/12) SLOPE INSULATED TAPERED GLASS ROOF W/ ALUM. MULLIONS RECLAIMED WOOD FASCIA DRAINAGE VIA NATURAL GRADE TO ALLEY INTEGR GUTTER 9" / 1'-0" 456788.5910 PR O P E R T Y L I N E CEMENT BOARD SIDING 9" / 1 ' - 0 " GOOSENECK LIGHT FIXTURE WITH FROSTED LENS, TYP. D.S. B' 7902.20 OOM 7901.20 RUN (T/ MASONRY) 42" HIGH GUARDRAIL 1 4 4 EST ELEVATION 1/4" = 1'-0"1 PROPOSED NORTH ELEVATION Show the 42" guards in elevation UP DN 3A-400 STAIR WIDTH 3'-2 1 / 2 " F.O. 3'-6" HOLD5'-9" 8.5 9 10 C.4 E.8 2500# CAPACITY6'-8" x 4'-3" CAB.8'-4" x 5'-9" HOISTWAY5'-0" PIT DEPTH 4'-4" 4 7/8" 2'-3 1/8"R.O.4'-3 3/8"2'-8" HOLD8'-4" 1 1A-504 1 1 1'-0" 1'-0" LAN D I N G 3'-11 5 / 8 " 5'-0" 1'-3 1 / 8 " STAIR WIDTH3'-4 3/8" LANDING4'-0 7/8" 1'-0" E E1 E E 5 3'-0" HIGH HANDRAIL SUB FLR. TENANT 'A' 7903.200" T/GABLE 0226'-6 7/8" T/PARAPET14'-8" 2ND LEVEL12'-0" NORTHWEST GRADE-3'-3" 1A-300 CEDAR SHAKE SHINGLES OVER GABLED ROOF, ROOF AT (9/12) SLOPE RECLAIMED WOOD FACIA GUTTER 9 12 912 2A-311 AC.2C.4E.8F.8 TENANT SPACE 'B' 101 A-5012 Sim A-5017Sim SUB FLR. TENANT 'B' 7902.20-1'-0"SUB FLR. MECH. ROOM 7901.20-2'-0" T/ ELEVATOR OVERRUN (T/ MASONRY)27'-0" 1A-504 1 11 6" METAL STUD @ 16" O.C., (3) LAYERS 5/8" TYPE X GYP. BD. UL 263 42'' HIGH GUARDRAIL 5 2'-11 " 5'-1 0 " 5'-3" 5 MIN. H E A D C L E A R A N C E 6'-10" 3A-400 8.5 9 10 C.4 E.8 F.O.3'-6" R.O.4'-3 3/8" HOLD8'-4" HOLD5'-9" 2500# CAPACITY6'-8" x 4'-3" CAB.8'-4" x 5'-9" HOISTWAY5'-0" PIT DEPTH 4 A-400 5'-0" LANDING 3'-11 5 / 8 " STAIR WIDTH 3'-2 1 / 2 " STAIR WIDTH 3'-3 5/8" 1 1A-504 LANDING4'-0 1/8"9'-0"LANDING3'-1 3/8"1'-0" 1'-0" 1'-0" 1'-0" E E2 E E E 3'-0" HIGHHANDRAIL STAIR WIDTH3'-0 3/4" LAN D I N G 3'-11 5 / 8 " 8'-0" 5 SUB FLR. TENANT 'A' 7903.200" ROOF21'-0" 2ND LEVEL12'-0" 3A-4008.5 9 10 NOTE:ELEVATOR WALLS NOT SHOWN FOR CLARITY SUB FLR. TENANT 'B' 7902.20-1'-0" SUB FLR. MECH. ROOM 7901.20-2'-0" 5'-3" 5'-1 0 " 2'-11 " HAND R A I L H E I G H T 3'-0" TENANT SPACE 'B' 101 1 1 HAND R A I L 3'-0" HANDRAIL 3'-0" 42'' HIGH GUARDRAIL 6" METAL STUD @ 16" O.C., (3) LAYERS 5/8" TYPE X GYP. BD. UL 263 MIN. H E A D C L E A R A N C E 6'-10 " 5 C CHANNEL6" METAL STUDSTEEL STRAP (3) LAYERS TYPE X GYP. BD. Scale PROJECT NUMBER DATE DRAWN BY CHECKED BY modif. modif. As indicated 11/1 4 / 2 0 1 9 8 : 3 7 : 1 8 A M A−400 2016−005 11.13.18 STAIRS &ELEVATOR CO M M E R C I A L DE V E L O P M E N T 232 E . M A I N S T . A S P E N , C O 1/2" = 1'-0"1 MAIN FLOOR STAIR PLAN 1/4" = 1'-0"3 BUILDING SECTION 1/2" = 1'-0"2 SECOND FLOOR STAIR PLAN 1/2" = 1'-0"4STAIR SECTION NO. DATE BY REVISION 1 05.24.19 MODIF.PERMIT DOCUMENT REVISIONS 2 09.25.18 MODIF.PERMIT SET 3 11.28.18 MODIF.ISSUED FOR BID 4 08.2.19 MODIF.PERMIT DOCUMENT REVISION #1 5 11.12.19 MODIF.PERMIT DOCUMENT REVISION #2 1 1 1 5 3" = 1'-0"5 1 HOUR CEILING - STAIR ENCLOSURE UL263 UL263 is not a designor assembly, it is atest. It appears thatyou are trying toreference UL I501.Revise. Subject: PlanCheck Page: A-411 WINDOW & DOOR ENLARGED PLAN & ELEVATION Page Index: 25 Author: nickt Color: File Name: Architectural Plan Set.232 E Main.2019.11.pdf The comcheck gives a U-factor of 0.34 for the sloped glazing. The U-factor must be for the entire skylight assembly, including the frame. Verify and document the U-factor in accordance with City policy: The following are acceptable methods under the 2015 IECC to verify fenestration U-factors as part of the building thermal envelope: 1.NFRC certification; label applied to window assembly and verified at field inspection. 2.Default values from 2015 IECC tables C303.1.3(1) C303.1.3(2), R303.1.3(1), and R303.1.3(2). 3.Default values from Table 4 U-Factors for Various Fenestration Products in 2013 ASHRAE Fundamentals Handbook chapter 15, pg. 15.3. To document the chain of custody, a certificate, affidavit or other evidence from the manufacturer confirming compliance with the above method is required. 4.Calculation methods in 2013 ASHRAE Fundamentals Handbook chapter 15, pg. 15.3: “U-Factor (Overall Coefficient of Heat Transfer)”. A calculation is required for the standard NFRC window size of 47.2” x 47.2”. To document the chain of custody, a certificate, affidavit or other evidence from the manufacturer confirming compliance with the above calculation is required. 5.U-ratings by an NFRC–accredited lab in accordance with NFRC-100. To document the chain of custody, verification labels affixed to the units by an accredited independent inspection agency or a certificate, affidavit or other evidence from the manufacturer confirming compliance with the above simulation or testing. Subject: PlanCheck Page: A-501 WALL DETAILS AT GROUND LEVEL Page Index: 29 Author: nickt Color: File Name: Architectural Plan Set.232 E Main.2019.11.pdf Protect exposed insulation per 2015 IECC C402.2.5. 1 A-310 6'-0"2'-8"6'-8 5/8" -411 2 4 A-411 3 4 C A-5005 A-5008 SUB FLR. TENANT 'A' 7903.200" T/GABLE 0328'-6 3/4" T/GABLE 0226'-6 7/8" B/GABLE16'-1 1/2" 2ND LEVEL12'-0" 1 A-310 11'-4" 2'-6 3/4" 6'-0"2'-8" C 2 A-600 3 4 SUB FLR. TENANT 'B' 7902.20-1'-0"CAST STONE BASE T T SUB FLR. TENANT 'A' 7903.200" T/GABLE 0328'-6 3/4" T/ LOWER GLAZING10'-0" 2ND LEVEL12'-0" 127°127° 13'- 1 1 / 8 " 27'-2 3/4" 9" / 1'-0" 9" / 1'-0" 16'-10"16'-10" SECOND FLOOR TENANT SPACE- 'B' 200 EG C.2F.8 106° A-502 8 A-5021 A-5025 A-5025 Sim SUB FLR. TENANT 'B' 7902.20-1'-0" PROVIDE A MIN. 30 MIL POLYVINYL BUTYRAL (PVB )INTERLAYER AT ALL SLOPED GLAZING 1 1 1 7 A-503 4A-411 ROOF OVERHANG 4 1'-11 1 / 4 " T PROJECT NUMBER DATE DRAWN BY CHECKED BY modif. modif. 8 P M 2016−005 11.13.18 WINDOW & DOOR ENLARGED PLAN& ELEVATION CO M M E R C I A L DE V E L O P M E N T 23 2 E . M A I N S T . AS P E N , C O NO. DATE BY REVISION 1 05.24.19 MODIF. PERMIT DOCUMENT REVISIONS 2 09.25.18 MODIF. PERMIT SET 3 11.28.18 MODIF. ISSUED FOR BID 4 08.2.19 MODIF. PERMIT DOCUMENT REVISION #1 1 The comcheck gives a U-factor of 0.34 for the sloped glazing. The U-factor must be for theentire skylight assembly, including the frame. Verify and document the U-factor inaccordance with City policy: The following are acceptable methods under the 2015 IECC to verify fenestration U-factors as part of the building thermal envelope:1.NFRC certification; label applied to window assembly and verified at field inspection.2.Default values from 2015 IECC tables C303.1.3(1) C303.1.3(2), R303.1.3(1), andR303.1.3(2).3.Default values from Table 4 U-Factors for Various Fenestration Products in 2013ASHRAE Fundamentals Handbook chapter 15, pg. 15.3. To document the chain ofcustody, a certificate, affidavit or other evidence from the manufacturer confirming compliance with the above method is required.4.Calculation methods in 2013 ASHRAE Fundamentals Handbook chapter 15, pg. 15.3:“U-Factor (Overall Coefficient of Heat Transfer)”. A calculation is required for the standardNFRC window size of 47.2” x 47.2”. To document the chain of custody, a certificate,affidavit or other evidence from the manufacturer confirming compliance with the abovecalculation is required. 5.U-ratings by an NFRC–accredited lab in accordance with NFRC-100. To document thechain of custody, verification labels affixed to the units by an accredited independentinspection agency or a certificate, affidavit or other evidence from the manufacturerconfirming compliance with the above simulation or testing. 2 03 31 00.J1 07 13 00.A3 Protect exposed insulation per 2015 IECC C402.2.5. Subject: PlanCheck Page: 2 Page Index: 2 Author: nickt Color: File Name: Energy Code Compliance Comcheck.232 E Main.2019.08.pdf Wall C6 has R30 cavity and R20 continuous insulation. Energy Code Compliance Comcheck.232 E Main.2019.08.pdf (5) Subject: PlanCheck Page: 2 Page Index: 2 Author: nickt Color: File Name: Energy Code Compliance Comcheck.232 E Main.2019.08.pdf Wall B1 has no cavity insulation. Subject: PlanCheck Page: 2 Page Index: 2 Author: nickt Color: File Name: Energy Code Compliance Comcheck.232 E Main.2019.08.pdf Wall E is an interior wall with sound batts. Subject: PlanCheck Page: 2 Page Index: 2 Author: nickt Color: File Name: Energy Code Compliance Comcheck.232 E Main.2019.08.pdf Wall C8 has R-30 cavity insulation. Subject: PlanCheck Page: 3 Page Index: 3 Author: nickt Color: File Name: Energy Code Compliance Comcheck.232 E Main.2019.08.pdf Sign the Comcheck. AWNEER, (c) 506 ------0.340 0.290 , Perf. .34, [Bldg. 60 ------0.350 0.770 ce Door, 0.33, VT 84 ------0.340 0.770 ce Door, 0.33, VT 290 ------0.340 0.770 routed, Cells nd Floor] 1225 0.0 15.0 0.055 0.071 Use 2 -476 21.0 15.0 0.041 0.064 pecs.:6 ------0.340 0.290 pen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN 11/13/19Report date: 132 ofPage Wall C6 has R30 cavity and R20 continuous insulation. e 1 - 97 ------0.290 0.290 e 1 - 108 ------0.290 0.290 .: e 1 - 22 ------0.340 0.290 Door, .45, 66 ------0.350 0.770 1 -476 21.0 15.0 0.041 0.064 .: e 1 - 54 ------0.290 0.290 Perf. Bldg. 45 ------0.290 0.290 Wall B1 has no cavity insulation. dg. Use 1 -476 21.0 15.0 0.041 0.064 rf. Specs.: [Bldg. Use 1 - 54 ------0.290 0.290 k:Fixed, Perf. VT 0.34, [Bldg. 45 ------0.290 0.290 ntrance Door, .14, VT 0.34, 63 ------0.350 0.770 Grouted, Cells round Floor] 35 0.0 15.0 0.055 0.071 dg. Use 1 -1224 21.0 15.0 0.041 0.064 D KAWNEER, oor] (c) 506 ------0.340 0.290 Door, Perf. VT 0.34, [Bldg. 60 ------0.350 0.770 rance Door, , PF 0.33, VT 84 ------0.340 0.770 Wall E is an interior wall with sound batts. Perimeter d, nd 477 0.0 15.0 0.055 0.071 oor]90 ------0.140 0.179 -807 21.0 15.0 0.041 0.064 ed, .34, 41 ------0.290 0.290 e 1 - 97 ------0.290 0.290 e 1 - 97 ------0.290 0.290 e 1 - 108 ------0.290 0.290 Wall C8 has R-30 cavity insulation. Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Product ID KAWNEEER, SHGC 0.27, VT 0.56, [Bldg. Use 2 - Second Floor] (c) Window 12 around door D: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID PORTELLA, SHGC 0.25, VT 0.34, [Bldg. Use 2 - Second Floor] (c) 48 ------0.290 0.290 Door 5 (type D): Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID PORTELLA, SHGC 0.22, VT 0.45, [Bldg. Use 2 - Second Floor] (c) 42 ------0.350 0.770 Exterior West Wall (type D): Concrete Block:8", Partially Grouted, Cells Empty, Normal Density, Furring: Metal, [Bldg. Use 1 - Ground Floor] 74 0.0 15.0 0.055 0.071 (a)Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b)'Other' components require supporting documentation for proposed U-factors. (c)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (d)Slab-On-Grade proposed and budget U-factors shown in table are F-factors. Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed envelope systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Envelope PASSES: Design 9% better than code Project Title: Data filename: 232 MAIN ST. C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN ST 3-12-19_permit comments.cck 11/13/19Report date: 133 ofPage Sign the Comcheck. Subject: PlanCheck Page: 1 Page Index: 1 Author: nickt Color: File Name: Interior Lighting Code Compliance.232 E Main.2019.08.pdf Provide egress lighting in the stairs. 2015 IBC 1008. Interior Lighting Code Compliance.232 E Main.2019.08.pdf (4) Subject: lighting cutsheets Page: 1 Page Index: 1 Author: nickt Color: File Name: Interior Lighting Code Compliance.232 E Main.2019.08.pdf Provide cutsheets for all light fixtures showing max fixture wattage and listing by a nationally recognized testing lab. Wattages must match the lighting Comchecks. Subject: PlanCheck Page: 1 Page Index: 1 Author: nickt Color: File Name: Interior Lighting Code Compliance.232 E Main.2019.08.pdf There are 17 F fixtures in the lighting plans. Subject: PlanCheck Page: 2 Page Index: 2 Author: nickt Color: File Name: Interior Lighting Code Compliance.232 E Main.2019.08.pdf I count 4 H fixtures and 8 B fixtures Subject: PlanCheck Page: 2 Page Index: 2 Author: nickt Color: File Name: Mechanical ComCheck Stamped and Signed.232 E Main.2019.08.pdf Revise mechanical comcheck to include the boiler and unit heaters shown in the mechanical plans. Mechanical ComCheck Stamped and Signed.232 E Main.2019.08.pdf (2) Chicago, IL 60607 3127148519 bhribar@centaurco.com sta do not meet the performance requirement will be identified in the m ge(s) ower A rea Category B Floor Area (ft2) 5690 Power A B Provide egress lighting in the stairs. 2015 IBC 1008. Total Pro Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent specifications, and other calculations submitted with this permit application. The proposed interior lightin designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any appli requirements listed in the Inspection Checklist. Name - Title Signature Da Interior Lighting PASSES: Design 88% better than code Project Title: Data filename: 232 E. Main Street C&S P:\Current Projects\18029.00 - 232 East Main Street\Calculations\COMcheck\Electrical COMcheck.cck 1 Stanton Humphries, PE Provide cutsheets for all light fixtures showing max fixture wattage and listing by a nationally recognized testing lab. Wattages must match the lighting Comchecks. Chicago, IL 60607 3127148519 bhribar@centaurco.com stan@aec-vail.com High efficiency HVAC. Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist report. Additional Efficiency Package(s) Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-Office 5690 0.82 4666 4666Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures 1-Office LED 1: F: Other:1 13 42 546 546Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES: Design 88% better than code 11/12/19Stanton Humphries, PE There are 17 F fixtures in the lighting plans. 3127148519 bhribar@centaurco.com Allowed Exterior Lighting Power A Area/Surface Category B Quantity C Allowed Watts / Unit D Tradable Wattage E Allowed Watts (B X C) Main entry 90 ft of door 30 Yes 2700 Total Tradable Watts (a) = Total Allowed Watts = Total Allowed Supplemental Watts (b) = 2700 2700 750 (a) Wattage tradeoffs are only allowed between tradable areas/surfaces. (b) A supplemental allowance equal to 750 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Main entry (90 ft of door width): Tradable Wattage LED 1: B: WALL SCONCE: Other:1 9 10 94 LED 1: C: WALL SCONCE: Other:1 2 17 34 LED 1: H: WALL SCONCE: Other:1 5 25 125 254Total Tradable Proposed Watts = Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Exterior Lighting PASSES: Design 93% better than code Project Title: Data filename: 232 E. Main Street C&S P:\Current Projects\18029.00 - 232 East Main Street\Calculations\COMcheck\Electrical 11/12/19Report date: 72 ofPage Stanton Humphries, PE 11/12/19 I count 4 H fixtures and 8 B fixtures Proposed Efficiency = 16.40 SEER, Required Efficiency: 14.00 SEER Fan System: RTU-4 FAN -- Compliance (Brake HP method) : Passes Fans: RTU 4 FAN Supply, Multi-Zone VAV, 2000 CFM, 3.0 motor nameplate hp, 1.8 design brake hp (1.8 max. BHP), 80. grade Electric Storage Water Heater, Capacity: 7 gallons Proposed Efficiency: 2.00 SL, %/h (if > 12 kW), Required Efficiency: 4.16 SL, %/h (if > 12 kW) 2 WH-1 & WH-2: Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the build specifications, and other calculations submitted with this permit application. The proposed mechanical systems ha designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable man requirements listed in the Inspection Checklist. Name - Title Signature Date Bryan Urban 07-26 Revise mechanical comcheck to include the boiler and unit heaters shown in the mechanical plans. Subject: PlanCheck Page: 2 Page Index: 2 Author: nickt Color: File Name: Mechanical ComCheck Stamped and Signed.232 E Main.2019.08.pdf Where are the water heaters in the plan? Subject: PlanCheck Page: [4] 18029 - M2(D-64)-M2.0 Page Index: 4 Author: nickt Color: File Name: Mechanical Plan Set.232 E Main.2019.11.pdf Penetrations are not permitted through the exit stair enclosure or exit passageway. 2015 IBC 1023.5, 1024.6 Mechanical Plan Set.232 E Main.2019.11.pdf (4) Subject: PlanCheck Page: [4] 18029 - M2(D-64)-M2.0 Page Index: 4 Author: nickt Color: File Name: Mechanical Plan Set.232 E Main.2019.11.pdf Fire dampers must be indicated at specific locations, not a general note. Provide fire dampers at these locations if choosing to make the incidental uses (trash and mechanical) fire rated. Other option is to seal the rooms from smoke and fire sprinkler them, which would remove the fire rating and damper requirement. 2015 IBC 509 Subject: PlanCheck Page: [4] 18029 - M2(D-64)-M2.0 Page Index: 4 Author: nickt Color: File Name: Mechanical Plan Set.232 E Main.2019.11.pdf Update backgrounds to match architecturals. Subject: PlanCheck Page: [6] 18029 - M3(D-64)-M3.0 Page Index: 6 Author: nickt Color: File Name: Mechanical Plan Set.232 E Main.2019.11.pdf Penetrations are not permitted through the exit stair enclosure or exit passageway. 2015 IBC 1023.5, 1024.6 Quantity System Type & Description Proposed Efficiency = 82.00% Et, Required Efficiency: 80.00 % Et or 78% AFUE Cooling: 1 each - Single Package DX Unit, Capacity = 41 kBtu/h, Air-Cooled Condenser, Air Economizer Proposed Efficiency = 16.40 SEER, Required Efficiency: 14.00 SEER Fan System: RTU-4 FAN -- Compliance (Brake HP method) : Passes Fans: RTU 4 FAN Supply, Multi-Zone VAV, 2000 CFM, 3.0 motor nameplate hp, 1.8 design brake hp (1.8 max. BHP), 80.0 fan efficiency grade Electric Storage Water Heater, Capacity: 7 gallons Proposed Efficiency: 2.00 SL, %/h (if > 12 kW), Required Efficiency: 4.16 SL, %/h (if > 12 kW) 2 WH-1 & WH-2: Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Bryan Urban 07-26-2019 Where are the water heaters in the plan? UP TENANT SPACE 'B' 101 ASH AREA (300 SF) 103 MECH. RM. 102 ELEV. JANITOR CLOSET 7 8 8.5 9 10 UH 1 UH 2 20x12-RA (22x14) 20x12-SA (22x14) T RTU-3 1 T RTU-2 1 12x8-EA (MAX 425 CFM) 3 3 UP EF 1 9"Ø-EA T EF-1 L-1680-EX 30x12 6 18x8-EA (MAX 680 CFM) B 1 4 20x12-RA (22x14) EF 2 6"Ø-EA 8 Penetrations are not permitted through the exit stair enclosure or exit passageway. 2015 IBC 1023.5, 1024.6 UP TENANT SPACE 'A' 100 TENANT SPACE 'B' 101 TRASH AREA (300 SF) 103 MECH. RM. 102 ELEV. 4 5 6 7 8 8.5 9 10 JANITOR CLOSET SHEET DETAIL NOTES: THERMOSTATS SHALL BE PROVIDED WITH ADDITIONAL WIRING TO ACCOMMODATE FUTURE RELOCATION. TERMINATE 8"Ø BOILER FLUE AND 8"Ø COMBUSTION AIR DUCT WITH WIRE MESH AND A GOOSE NECK DOWN ON THE INTAKE. ENSURE A 36" MIN SEPARATION FROM INTAKE AND VENT. TERMINATION SHALL BE AT LEAST 7'-0" ABOVE ANY PUBLIC WALKWAY AND 3'-0" ABOVE ANY FORCED AIR INTAKE WITHIN 10'-0". DUCT CAPPED FOR FUTURE USE. ROUTE BOILER FLUES FROM BOILERS TO TERMINATION PER MANUFACTURER'S INSTRUCTIONS. SLOPE VENT PIPES AT 14"/FOOT BACK TO THE BOILER FOR ALL HORIZONTAL RUNS. MAINTAIN 1" CLEARANCE TO COMBUSTIBLES. DO NOT EXCEED 100' MAXIMUM DEVELOPED LENGTH FOR ANY RUN. ESTIMATED LENGTHS AND ELBOWS FOR LONGEST RUN BOILER ARE SHOWN BELOW: B-1 VENT (CPVC):HORIZONTAL DISTANCE:25' VERTICAL DISTANCE: 10' 90 DEGREE ELBOWS:(5')(2) = 10' 45 DEGREE ELBOWS:(3')(0) = 0' TERMINATION:5' MAX DEVELOPED LENGTH:50' B-1 CA (PVC):HORIZONTAL DISTANCE:25'VERTICAL DISTANCE: 10' 90 DEGREE ELBOWS:(5')(2) = 10' 45 DEGREE ELBOWS:(3')(X) = 0' TERMINATION:5' MAX DEVELOPED LENGTH:50' FOLLOW ALL MANUFACTURER'S INSTRUCTIONS FOR BOILER VENTING MATERIALS. PROVIDE CPVC ROUTING FOR THE BOILER FLUES (PVC IS ACCEPTABLE FOR THE COMBUSTION AIR). PVC IS NOT ALLOWED FOR ANY BOILER FLUE ROUTINGS. INSTALL ROOFTOP UNITS PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. UNIT SHALL BE PLACED ON 14" ROOF CURB. AECIS NOT ABLE TO PROVIDE ACOUSTICAL MODELING OF EXTERIOR EQUIPMENT, NOR PROVIDE DOCUMENTATION SUPPORTING COMPLIANCE WITH THE CITY OF ASPEN NOISE ORDINANCE. AN ACOUSTICAL CONSULTANT IS RECOMMENDED TO VERIFY COMPLIANCE. NOISE MITIGATION MEASURES (BY OTHERS) MAY BE REQUIRED. INSTALL LOUVER L-2 SUCH THAT IT TERMINATES 3'-0" AWAY FROM NATURAL AIR INTAKES, 10'-0" FROM PROPERTY LINE, 7'-0" ABOVE WALKWAYS, 3'-0" ABOVE GROUND OR 12" ABOVE SNOW LEVEL (WHICHEVER IS HIGHER). ALL EXTERIOR DUCTWORK SHALL BE WRAPPED WITH 2" THICK INSULATION AND WEATHERPROOFED WITH ALUMINUM JACKET SLOPED TO AVOID WATER PONDING. TERMINATE WITH WALL CAP. ENSURE ADEQUATE CLEARANCE BETWEEN NEAREST BUILDING OPENING. COORDINATE EXACT LOCATION WITH ARCHITECT. 2.ALL INTERIOR SUPPLY AND RETURN DUCTWORK SHALL INCLUDE 1" LINER UNLESS OTHERWISE NOTED. ALL OUTSIDE AIR INTAKE AND ROUND DUCTWORK SHALL BE WRAPPED WITH 1.5" THICK INSULATION UNLESS OTHERWISE NOTED. 3.ALL SQUARE 90 DEGREE ELBOWS SHALL HAVE TURNING VANES. 4.ALL DUCTWORK SHALL BE RUN TIGHT TO UNDERSIDE OF STRUCTURE WHERE IT EXISTS UNLESS OTHERWISE NOTED. 5.ALL DUCTWORK PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL INCLUDE FIRE DAMPERS RATED TO MATCH THAT OF THE ASSEMBLY. 6.COORDINATE ALL ACCESS PANEL LOCATIONS WITH THE ARCHITECT. UH 1 UH 2 46x14-RA UP(48x16)30x20-SA UP (32x22) 38x16-SA (40x18)46x14-RA (48x16) 20x12-SA UP (22x14) 20x12-RA (22x14) 20x12-SA (22x14) T RTU-1 1 2 1 T RTU-3 1 T RTU-2 1 12x8-EA(MAX 425 CFM) 3 4 2 5 3 3 3 3 6 20x12-RA UP (22x14) EF 1 9"Ø-EA T EF-1 7 L-1680-EX30x12 6 18x8-EA(MAX 680 CFM) 30x16-SA (32x18) 3 3 30x16-RA (32x18) B 1 4 20x12-RA(22x14) EF 2 6"Ø-EA 8 8 Fire dampers must be indicated at specific locations, not a general note. Provide fire dampers at these locations if choosing to make the incidental uses (trash and mechanical) fire rated. Other option is to seal the rooms from smoke and fire sprinkler them, which would remove the fire rating and damper requirement. 2015 IBC 509 UP TENANT SPACE 'B' 101 TRASH AREA (300 SF) 103 MECH. RM. 102 ELEV. 6 7 8 8.5 9 10 C.2 C.4 E.8 F.8 JANITOR CLOSET 6 7 8 8.5 9 10 OTES: ROVIDED WITH ADDITIONAL WIRING TO ELOCATION. UE AND 8"Ø COMBUSTION AIR DUCT OOSE NECK DOWN ON THE INTAKE. TION FROM INTAKE AND VENT. LEAST 7'-0" ABOVE ANY PUBLIC ANY FORCED AIR INTAKE WITHIN 10'-0". E USE. M BOILERS TO TERMINATION PER CTIONS. SLOPE VENT PIPES AT 14"/FOOT ALL HORIZONTAL RUNS. MAINTAIN 1" BLES. DO NOT EXCEED 100' MAXIMUM ANY RUN. ESTIMATED LENGTHS AND N BOILER ARE SHOWN BELOW: IZONTAL DISTANCE:25' TICAL DISTANCE: 10' EGREE ELBOWS:(5')(2) = 10' EGREE ELBOWS:(3')(0) = 0' MINATION:5' DEVELOPED LENGTH:50' IZONTAL DISTANCE:25' TICAL DISTANCE: 10' EGREE ELBOWS:(5')(2) = 10' EGREE ELBOWS:(3')(X) = 0' MINATION:5' DEVELOPED LENGTH:50' ER'S INSTRUCTIONS FOR BOILER VIDE CPVC ROUTING FOR THE BOILER E FOR THE COMBUSTION AIR). PVC IS OILER FLUE ROUTINGS. S: ARE SHOWN INSIDE TO INSIDE. ETURN DUCTWORK SHALL INCLUDE 1" OTED. ALL OUTSIDE AIR INTAKE AND WRAPPED WITH 1.5" THICK ISE NOTED. OWS SHALL HAVE TURNING VANES. N TIGHT TO UNDERSIDE OF S UNLESS OTHERWISE NOTED. OUGH FIRE-RATED ASSEMBLIES S RATED TO MATCH THAT OF THE NEL LOCATIONS WITH THE ARCHITECT. UH 1 UH 2 20x12-SA UP(22x14) 20x12-RA (22x14) 20x12-SA (22x14) T RTU-3 1 T RTU-2 1 12x8-EA(MAX 425 CFM) 2 3 3 5 20x12-RA UP(22x14) EF 1 9"Ø-EA T EF-1 L-1680-EX30x12 6 18x8-EA(MAX 680 CFM) B 1 4 20x12-RA (22x14) EF 2 6"Ø-EA 8 Update backgroundsto matcharchitecturals. UP TENANT SPACE 'B' 101 TRASH AREA (300 SF) 103 MECH. RM. 102 ELEV. JANITOR CLOSET SZ 3-1 188 SF SZ 4-1 172 SF SM 3 SM 4 1 2" SMS/R 2" SMS/R 1-1/4" SMS/R 1-1/4" SMS/R 2-1/2" SMS/R S 3 4 SZ 3-2 530 SF SZ 4-2 411 SF 1-1/2" SMS/R 2" SMS/R 1 Penetrations are not permitted through the exit stair enclosure or exit passageway. 2015 IBC 1023.5, 1024.6