Loading...
HomeMy WebLinkAboutFile Documents.541 Race St.0197.2019.ARBK0197-2019-ARBK_BuildingComment1 Subject: PlanCheck Page Label: [1] 17.001C Race Alley PLANS-S1.01 Author: stephenk Color: File Name: 541 Race - Gas Line Routing Rudd.pdf Gas line shall not penetrate foundation wall below grade. 2015 IFGC 404.6 Revisions to structural plans shall be made by engineer of record. Protect gas meter from ice and snow. 541 Race - Gas Line Routing Rudd.pdf (1) Subject: PlanCheck Page Label: [1] S1.02 Author: stephenk Color: File Name: Floor Framing revisions Race Alley - S1 02 REV 2.pdf revise detail 9/S5.02 to show new framing Floor Framing revisions Race Alley - S1 02 REV 2.pdf (1) T.O. SLAB = 89'-714" 8" CONC BASEMENT WALL - TYP U.N.O. 8" CONC FOUNDATION WALL w/ #5 @ 12"o.c.EA WAY CTRD - TYP U.N.O. 5 S5.01 T.O. WALL 103'-0" T.O. FOOTING 100'-0" T.O. WALL 99'-5" T.O. LEDGE 99'-5" T.O. WALL 99'-1114"T.O. WALL 99'-438" T.O. WALL 99'-9" T.O. FTG 93'-0" T.O. FTG 97'-0" T.O. FTG 97'-0" T.O. WALL 101'-10" W10 CONT STAIR STRINGER T.O. WALL 100'-0" T.O. LEDGE 98'-712" T.O. WALL 103'-0" 3'- 4 14" CONC CURB PER 4/S5.01TYP - LOCATE PER ARCH FC16 - TYP @ GARAGE T.O. CURB 89'-714" 26'-8"10'-1"22'-0" 3'-8"11'-812" 11'-8" 6'-8" 8" RE: 7 / S 2 . 0 TYP @ 9STL CO L A B O V E 10 S5.01 FC24 - TYP @ BASEMENT WALL T.O. FTG 88'-1114" T.O. FTG 88'-1114" 3'-8" T.O. WALL 100'-914" T.O. FTG 88'-1114" T.O. WALL 100'-0" T.O. WALL 99'-4" TYPICAL SLAB ON GRADE 4" CONCRETE SLAB ON INSUL PER ARCH ON APPROVED NATIVE OR PREPARED SUBGRADE PER GEOTECH REPORT. REINFORCE SLAB WITH 6x6-W2.1xW2.1 WWF OR #3 @ 12"o.c EA WAY - CENTERED. PROVIDE 114" DEEP SAW-CUT CONTROL JOINTS @ 12'-0" o.c. MAX EACH WAY - TYP T.O. LEDGE 99'-1012" TYP U.N.O. 8" WINDOW WELL WALL w/ #5 @ 12"o.c. EA WAY CTRD w/ TAPERED TOP PER ARCH - TYP 8" W x 2'-0" DP CONC HDR MIN w/ (2) #5 T&B AND #5 @ 12"o.c. HORIZ E.F. w/ #3 TIES @ 12"o.c. - TYP @ 2 B.O. CONC HDR PER ARCH - TYP @ 2 4'-9" T.O. WALL 100'-0"T.O. LEDGE FOR GRATING PER ARCH T.O. LEDGE FOR GRATING PER ARCH 12 S5.01 T.O. SLAB = 102'-6" SLOPE TO DRAIN T.O. LEDGE 101'-10" T.O. LEDGE 99'-812" 12" DP x 6'-6" WIDE CONC FTG w/ #5 @ 16"o.c. T&B EA WAY TYP (2) SIDESCONC BUTTRESS WALL w/ #5 @12"o.c.EA WAY E.F. Gas line shall not penetrate foundation wall below grade. 2015 IFGC 404.6 Revisions to structural plans shall be made by engineer of record. Protect gas meter from ice and snow. LAUNDRY HALL W10x39 - 2x NA T.O. STL = 99 W10x68 CO STAIR STR W10x39 W10x22 ROOFING ASSEMBLY w/ WATERPROOFING & FLASHING PER ARCH 9 S5.02 11 S5.02T.O. PLY = 99'-658" P.T. 2x8 @ 16"o.c. 11'-8" D STRUCTURE FY S.E.O.R. OF SIGN PRIOR TO S. (2) 714" LVL HU48 2 revise detail 9/S5.02 to show new framing 03/24/2020