Loading...
HomeMy WebLinkAboutFile Documents.802 E Cooper Ave.0011-2020-BCHO (2)Scale: AS NOTED ISSUE PROGRESS SET RDS SUBMITTAL PROGRESS SET ZONING REVIEW PROGRESS SET PERMIT SUBMITTAL WALL DEMOLITION CALCULATIONS 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTURE + INTERIORS AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.1.06 4/10/20 DATE UN I T 3 R E M O D E L 80 2 E A S T C O O P E R A V E N U E AS P E N , C O 8 1 6 1 1 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . C O O P E R A V E N U E , S U I T E 2 0 1 ww w . k i m r a y m o n d a r c h i t e c t s . c o m 97 0 - 9 2 5 - 2 2 5 2 9/27/19 10/3/19 10/15/19 10/18/19 11/19/19 12/2/19 1,305 sq ft 27 sq ft 16 sq ft 11 sq ft 14 sq ft 37 sq ft 4 sq ft 14 sq ft 16 sq ft 124 sq ft 2,094 sq ft 135 sq ft 26 sq ft 13 sq ft 16 sq ft 13 sq ft 51 sq ft 16 sq ft 36 sq ft 10 sq ft 21 sq ft 7 sq ft 48 sq ft 46 sq ft 98 sq ft 33 sq ft 23 sq ft 21 sq ft 15 sq ft 89 sq ft 16 sq ft 55 sq ft 22 sq ft 64 sq ft 43 sq ft 5 sq ft 1,344 sq ft 20 sq ft 193 sq ft 173 sq ft 1 2,056 sq ft 5 sq ft 11 sq ft 24 sq ft 21 sq ft 11 sq ft 8 sq ft 8 sq ft 20 sq ft 4 sq ft 4 sq ft 8 sq ft 341 sq ft 10 sq ft Individual Wall Area (Sq Ft) Area Reduced for Fenestration (Sq Ft) Area of Wall to be Removed (Sq Ft) SCALE: 3/16" = 1'-0"4 EXISTING NORTH ELEVATION DEMO SCALE: 3/16" = 1'-0"2 EXISTING WEST ELEVATION DEMO SCALE: 3/16" = 1'-0"1 EXISTING SOUTH ELEVATION DEMO SCALE: 3/16" = 1'-0"3 EXISTING EAST ELEVATION DEMO DEMOLITION LEGEND TOTAL DEMO: 20.06% Scale: AS NOTED ISSUE PROGRESS SET RDS SUBMITTAL PROGRESS SET ZONING REVIEW PROGRESS SET PERMIT SUBMITTAL ROOF DEMOLITION CALCULATIONS 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTURE + INTERIORS AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.1.07 4/10/20 DATE UN I T 3 R E M O D E L 80 2 E A S T C O O P E R A V E N U E AS P E N , C O 8 1 6 1 1 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . C O O P E R A V E N U E , S U I T E 2 0 1 ww w . k i m r a y m o n d a r c h i t e c t s . c o m 97 0 - 9 2 5 - 2 2 5 2 9/27/19 10/3/19 10/15/19 10/18/19 11/19/19 12/2/19 A. 42 sq ft ROOF BELOW C. 70 sq ft ROOF BELOW E.50 sq ft ROOF BELOW B.18 sq ft D.1,067 sq ft I. 73 sq ft F.886 sq ft Existing Roof to Remain (Sq Ft) Area of Roof to be Removed (Sq Ft) Area Reduced for Fenestration (Sq Ft) G.367 sq ft H.158 sq ft J. 268 sq ft 18 sq ftSKY-LIGHT SCALE: 3/16" = 1'-0"1 DEMO ROOF PLAN TOTAL DEMO: 20.06%