Building Permit Comment Responses
Date: 2019.08.14
Project Name: 2017910 Pitkin County Courthouse Remodel
506 East Main Street, Aspen, Colorado
Permit Number: 0054.2019.ACBK
Code: 2015 IEBC, IBC
Reviewer: Bonnie Muhigirwa
Plans Examiner
Community Development
2019.05.29 Mechanical pdf:
M0.1 Mechanical Legend and Notes
Thermostat heights to comply with reach ranges in ICC A117.1-2009.308
Response:
Sheet M0.1, Mechanical Note, III Execution note C has been updated with the following
language, “Thermostats shall be mounted at a maximum of 48” above finished floor to the top
of the thermostat.” Per ICCA117.1-2009.308
2019.05.29 Pitkin Permit Electrical:
ED1.0 Garden Level Electrical Plan
620.22, Branch Circuits for car lighting receptacle(s) ventilation, heating and air conditioning (A)
Car light source. A separate branch circuit shall supply the car lights, receptacle(s) auxiliary
lighting power source and ventilation on each elevator car. The over current device protecting
the branch circuit shall be located in the elevator machine room or control room/machinery
space or control space. Required lighting shall not be connected to the load side of the ground
fault circuit interrupter.
Response:
Keynote #4, Sheet ED1.0 and keynote#17, Sheet E1.0 have been revised asking the contractor
to verify the existing elevator cab lights are on a dedicated circuit to comply with NEC 620.22
(A).
2019.06.14 Pitkin Permit – Architectural:
A1.0 Garden Level Floor Plan
Per the code summary on G0.4, the occupant load in the garden level courtroom exceeds 50,
correct the door swing so that the doors swing in the direction of egress travel per 2015 IEBC
805.4.2
08/21/2019
CR
A
F
T
B
A
L
A
N
C
E
WH
I
M
S
Y
30
3
2
7
8
4
3
7
8
7
1
5
F
O
U
R
T
E
E
N
T
H
S
T
R
E
E
T
,
G
O
L
D
E
N
,
C
O
8
0
4
01
AN
D
A
R
C
H
.
C
O
M
AN
D
E
R
S
O
N
H
A
L
L
A
S
A
R
C
H
I
T
E
C
T
S
2
Response:
Courtroom 3 occupancy was calculated per the 2015IBC, Table 1004.1.2
Courtroom 40sf net per occupant
Room Area load factor occupant load
Courtroom 1,244sf 40sf per occ 32 total occupants
Sheet A1.0 door swing from Court Room 3 remains unchanged.
Sheet G.04 has been revised
2019.06.14 Pitkin Permit – Architectural:
A1.0 Garden Level Floor Plan
Per 2015 IEBC 705, 705.2, this alteration affects the area of primary function and therefore the
toilet facilities serving the area of primary function shall be accessible to the maximum extent
possible that is technically feasible. Revise door widths to provide clear openings widths of 32
inches minimum. Provide an accessible route toilet compartment, grab bars and under counter
pipe protection in the men’s restroom.
Response:
No work is associated with Women’s Room 00C or Men’s Room 00D. Graphically, both
restrooms have been updated to better reflect existing conditions. Doors 00C and 00D into
the Women’s and Men’s restroom are not 32 inches clear. Due to the historic nature of the
historic stone openings, increasing the size of the existing restroom doors is technically
infeasible. Door stalls have been updated to reflect a 32inch clear opening. Door reach
ranges, however, do not meet accessibility.
Per 2015 IEBC: 705.1 General: Where compliance with this section, is technically infeasible, the
alteration shall provide access to the maximum extent possible.
Both Women’s Room 00C and Men’s Room 00D currently have horizontal grab bars. The
project will provide new vertical grab bars per ANSI 604.5.1 Fixed Side Wall Grab Bars and
pipe protection per ANSI 606.6 Exposed Pipes and Surfaces. Keynote 30 has been added on
Sheet A1.0 to reflect the inclusion of fixed vertical grab bars and knee protection.
The existing hardware is being removed and replaced with new accessibly compliant hardware
Per the 2015 IEBC section 1204.1.4 toilet and Bathing Facilities:
Where toilet rooms are provided, at least one accessible family or assisted-use toilet room
complying with Section 1109.1.1 of the International Building Code shall be provided.
Per the 2015 IBC section 1109.2.4.1 Location:
Family or assisted-use toilet and bathing rooms shall be located on an accessible route.
Family or assisted-use toilet rooms shall be located not more than one story above or below
separate sex toilet rooms. The accessible route from any separate sex toilet room to a family
or assisted-use toilet room shall not exceed 500 feet.
08/21/2019
CR
A
F
T
B
A
L
A
N
C
E
WH
I
M
S
Y
30
3
2
7
8
4
3
7
8
7
1
5
F
O
U
R
T
E
E
N
T
H
S
T
R
E
E
T
,
G
O
L
D
E
N
,
C
O
8
0
4
01
AN
D
A
R
C
H
.
C
O
M
AN
D
E
R
S
O
N
H
A
L
L
A
S
A
R
C
H
I
T
E
C
T
S
3
.
Existing Women’s Room 114 and Men’s Room 113 on the Main Level will be made fully
compliant (see following comments referencing A1.1 Main Level Floor Plan). In addition, all
new restrooms will be fully accessible.
Travel distance from the Garden Level to the Main Level is less than 500 feet
Travel distance from the Second Level to the Main Level is less than 500 feet.
2019.06.14 Pitkin Permit – Architectural:
A1.1 Main Level Floor Plan
Per 2015 IEBC 705 and 705.2, this alteration affects that primary function and therefore the
toilet facilities serving the area of primary function shall be accessible to the maximum extent
that is technically feasible. Revise door widths to provide clear opening width of 32 inches
minimum. Provide an accessible toilet compartment, grab bars and under counter pipe
protection in men’s restroom.
Response:
No work is anticipated in Women’s Room 114 or Men’s Room 113. Men’s Restroom 113 was
revised graphically to reflect the existing door swing properly. Both restrooms are accessible,
however, are missing vertical grab bars and pipe protection.
Both Women’s Room 114 and Men’s Room 114 currently have horizontal grab bars. The project
will provide new vertical grab bars per ANSI 604.5.1 Fixed Side Wall Grab Bars and pipe
protection per ANSI 606.6 Exposed Pipes and Surfaces. Keynote 30 has been added on Sheet
A1.1 to reflect the inclusion of fixed vertical grab bars and knee protection.
See updated sheet A1.1
2019.06.14 Pitkin Permit – Architectural:
A5.0 Door Schedule
1. Confirm that the following 2’-10” doors provide the minimum clear width of 32” per 2015 IBC
1010.1:00, 04 100; 105C, 108A, 113. 114. 2020C, 203.
Response:
Doors 100, 105C, 108A, 113, 114, 202C and 203 are existing historic doors. The doors are hung
within their original frames in deep masonry walls. On either side of the door are decorative
moldings that are integral with the original transom above. The doors and trim are character
defining features. Existing doors slabs are 34 inches wide and 1.75 inches thick. Existing
doorstops are 3/8” thick. The clear opening is 31-7/8” clear. To provide a 32” clear opening
would cause irrevocable damage to existing historic fabric and is technically infeasible per
IEBC section1204.4 accessibility requirements, where compliance with the requirements would
threaten or destroy the historic significance of the building or facility.
Existing door hardware does not meet accessibility requirements. All existing hardware will be
replaced and updated for compliance.
Reference specification section 08 71 00 for door hardware schedule.
08/21/2019
CR
A
F
T
B
A
L
A
N
C
E
WH
I
M
S
Y
30
3
2
7
8
4
3
7
8
7
1
5
F
O
U
R
T
E
E
N
T
H
S
T
R
E
E
T
,
G
O
L
D
E
N
,
C
O
8
0
4
01
AN
D
A
R
C
H
.
C
O
M
AN
D
E
R
S
O
N
H
A
L
L
A
S
A
R
C
H
I
T
E
C
T
S
4
2019.06.14 Pitkin permit – Architectural:
A5.0 Door Schedule
Correct the following doors to provide the required 32” clear width per 2015 IBC 1010.1.1: 108B,
108C.
Response:
Doors 108B and 108 C are existing historic doors to remain with no work. On either side of the
door are decorative moldings that are integral with the original transom above. The doors
and trim are character defining features. Existing doors slabs are 2’-8” inches wide and 1.75
inches thick. Existing doorstops are 3/8” thick. The clear openings are 29-7/8” clear. To
provide a 32” clear opening would cause irrevocable damage to existing historic fabric and is
technically infeasible per IEBC section1204.4 accessibility requirements, where compliance
with the requirements would threaten or destroy the historic significance of the building or
facility.
Existing door hardware does not meet accessibility requirements. All existing hardware will be
replaced and updated for compliance.
A new accessible office will be provided within the Probation Suite. The accessible door will
provide a 32” clear opening.
See sheet A1.1
2019.06.14 Pitkin Permit – Architectural:
A7.3 Enlarged Plans at New Lift Entry
3’-5”
Response:
Sheet A7.3 has been updated to reflect a 42” clear side door opening at the main level.
2019.06.14 Pitkin Permit – Architectural:
A7.3 Enlarged Plans at New Lift Entry
Side door on lift require a clear opening width of 42” minimum. ICC A117.1-2009 410.2.1
Response:
Sheet A7.3 has been updated to reflect a 42” clear side door opening at the main level.
08/21/2019
CR
A
F
T
B
A
L
A
N
C
E
WH
I
M
S
Y
30
3
2
7
8
4
3
7
8
7
1
5
F
O
U
R
T
E
E
N
T
H
S
T
R
E
E
T
,
G
O
L
D
E
N
,
C
O
8
0
4
01
AN
D
A
R
C
H
.
C
O
M
AN
D
E
R
S
O
N
H
A
L
L
A
S
A
R
C
H
I
T
E
C
T
S
5
2019.06.14 Pitkin Permit – Architectural:
A9.2 Interior Elevations
Knee and toe clearances must be provided at the jury deliberation sinks. ICC A117.1-2009 606.2.
Response:
The following drawings have been updated to reflect a front approach to new sinks.
2 & 5: A9.2
1:A9.8
2& 3:A9.11
The swing clear cabinet doors at base cabinet locations have been removed and replaced with
a removable apron. The removable apron will provide the required knee and toe floor space at
the front of each sink and provide knee protection.
2019.06.14Pitkin Permit – Architectural:
A9.2 Interior Elevations
A parallel approach to the sink is required when knee/toe clearances are not provided. ICC
A117.1-2009 606.2 exception 1. The dishwasher in the open position cannot encroach in the clear
floor space of the sink 804.5.3.
Response:
See comment above. All swing clear cabinet doors have been removed and replaced with a
removeable sink apron. The removable apron will provide the required knee and toe floor
space at the front of each sink and provide knee protection.
2019.06.14 Pitkin Permit – Architectural
A9.7 Interior Elevations – DA
A parallel approach to the sink is required when knee/toe clearances are not provided. OCC
A117.1-2009 606.2 exception 1
Response:
Sink in DA office 101 has been updated to provide a front approach to the sink. The swing
away cabinet doors have been replaced with a removable apron. The removable apron will
provide the required knee and toe floor space at the front of each sink and provide knee
protection.
See revised interior elevation 2:A9.7.
08/21/2019
CR
A
F
T
B
A
L
A
N
C
E
WH
I
M
S
Y
30
3
2
7
8
4
3
7
8
7
1
5
F
O
U
R
T
E
E
N
T
H
S
T
R
E
E
T
,
G
O
L
D
E
N
,
C
O
8
0
4
01
AN
D
A
R
C
H
.
C
O
M
AN
D
E
R
S
O
N
H
A
L
L
A
S
A
R
C
H
I
T
E
C
T
S
6
2019.06.14 Pitkin Permit – Architectural:
G0.1 Cover Sheet
Per information provided on the asbestos verification checklist, this project requires an asbestos
test. Provide an asbestos test report that includes the following: Inspector’s narrative including
sampling locations 2. Inspector’s certificate 3. Lab data. If asbestos is found, a final air
clearance report must be provided to building permit issuance.
Response:
Asbestos report is attached.
2019.06.14 Pitkin Permit – Architectural
G0.1 Cover Sheet
The special inspection agreement needs to be completed and signed by all parties prior to permit
issuance.
Response:
See Attached
2019.06.14 Pitkin Permit – Architectural
G0.3 General Information
Provide the full installation instruction from the Gypsum Manual for WP 1072, WP 3510,
WP6800, FCU3510 in the plan set for reference and inspection.
Response:
Sheet G0.3 wall types have been updated with full installation instructions from the Gypsum
Manual.
Revised sheets G0.3G0.4A1.0A1.1A5.0A7.3A9.2A9.7A9.8A9.11A0.1E1.0ED1.0
08/21/2019
506 E Main_BuildingComments_1_Markup Summary
File Name: 2019.05.29 Mechanical.pdf
Author: bonniem
Subject: PlanCheck
Color:
Page Label: M0.1 MECHANICAL LEGEND AND NOTES
Thermostat heights to comply
with reach ranges in ICC
A117.1-2009 308.
2019.05.29 Mechanical.pdf (1)
File Name: 2019.05.29 Pitkin Permit Electrical.pdf
Author: mitchm
Subject: Electrical Code
Color:
Page Label: ED1.0 GARDEN LEVEL ELECTRICAL PLAN
DEMO
620.22 Branch Circuits for Car
Lighting, Receptacle(s),
Ventilation, Heating, and
Air-Conditioning.
(A) Car Light Source. A separate
branch circuit shall supply
the car lights, receptacle(s),
auxiliary lighting power source,
and
ventilation on each elevator car.
The overcurrent device
protecting
the branch circuit shall be
located in the elevator machine
room or control room/machinery
space or control space.
Required lighting shall not be
connected to the load side of
a ground-fault circuit interrupter
2019.05.29 Pitkin Permit Electrical.pdf (1)
File Name: 2019.06.14 Pitkin Permit - Architectural.pdf
Author: bonniem
Subject: PlanCheck
Color:
Page Label: A1.0 GARDEN LEVEL FLOOR PLAN
Per the code summary on G0.4,
the occupant load of the garden
level courtroom exceeds 50,
correct door swing so that doors
swing in the direction of egress
travel per 2015 IEBC 805.4.2
2019.06.14 Pitkin Permit - Architectural.pdf (13)
File Name: 2019.06.14 Pitkin Permit - Architectural.pdf
Author: bonniem
Subject: PlanCheck
Color:
Page Label: A1.0 GARDEN LEVEL FLOOR PLAN
Per 2015 IEBC 705, 705.2, this
alteration affects the area of
primary function and therefore
the toilet facilities serving the
area of primary function shall be
accessible to the maximum
extent that is technically feasible.
Revise door widths to provide
clear opening width of 32 inches
minimum. Provide an accessible
toilet compartment, grab bars
and under counter pipe
protection in the men's restroom.
PRESSURE SENSOR
THERMOSTAT
METER
FLOW ARROWG. FIRE/SMOKE DAMPERS: COMBINATION FIRE/SMOKE DAMPERS SHALL BE FABRICATED IN ACCORDANCE WITH NFPA 90A ANDUL555S CLASS II. FIRE/SMOKE DAMPERS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S UL INSTALLATIONINSTRUCTIONS. ACTUATORS SHALL BE POWER OPEN/SPRING CLOSED OPERATION, 120 VOLT. THE FIRE FAIL/SAFE MODE SHALLBE A UL 33 HEAT ACTUATED LINK FOR CLOSURE AND CONTAINMENT OF FIRE ZONE, INDEPENDENT OF ACTUATOR POSITIONINGOR SIGNALING. MANUFACTURED BY PREFCO, MODEL 5020 OR EQUAL.
H. HOT WATER HEATING PIPING/CHILLED WATER PIPING/CONDENSER WATER PIPING: ABOVEGROUND, NPS 2" AND SMALLER, SHALLBE ANY OF THE FOLLOWING:1. TYPE L, DRAWN-TEMPER, COPPER TUBING, WROUGHT-COPPER FITTINGS, AND SOLDERED JOINTS.2. SCHEDULE 40, GRADE B, TYPE 96 STEEL PIPE; CLASS 150, MALLEABLE IRON FITTINGS, CAST-IRON FLANGES AND FLANGEFITTINGS, AND THREADED JOINTS.
K. HYDRONIC PIPING INSULATION: MINERAL-FIBER, PREFORMED PIPE INSULATION: TYPE 1, 850° F. MINERAL OR GLASS FIBERSBONDED WITH A THERMOSETTING RESIN. COMPLY WITH ASTMC 547, TYPE 1, GRADE A, WITH FACTORY APPLIED ASJ.1. HEATING WATER 1-1/2" AND SMALLER = 1.5" THICK, HEATING WATER 2" AND LARGER = 2" THICK, CONDUCTIVITY = 0.27 @125° F.2. CHILLED WATER = 1.0 " THICK, CONDUCTIVITY = 0.25 @ 75° F.
III. EXECUTION
A. BALANCING:1. CONTRACTOR SHALL ADJUST AND BALANCE VARIABLE VOLUME BOXES (VAV'S), FAN POWERED BOXES (FPB'S), AIRCONDITIONING UNITS (AC'S), AND DIFFUSERS TO THE QUANTITIES SHOWN ON THE DRAWING. BALANCING WORK SHALL BEPERFORMED IN ACCORDANCE WITH NEBB OR TABB STANDARDS BY A NEBB OR TABB CERTIFIED CONTRACTOR. SUBMITBALANCING REPORT TO THE ENGINEER.2. EXISTING DIFFUSER DESIGNATION INDICATES CFM ONLY.3. VAV BOX DESIGNATION INDICATES MAXIMUM CFM ADJUST MINIMUM TO 10% OF MAXIMUM.4. WHERE LOW PRESSURE AIR HANDLING SYSTEMS CROSS INTO AN ADJACENT TENANT AREA, CONTRACTOR SHALLBALANCE ALL DIFFUSERS ASSOCIATED WITH THE SYSTEM. DIFFUSERS NOT SHOWN OR SHOWN WITH NO CFM SHALLMAINTAIN EXISTING CFM.5. ADJUST WATER SYSTEMS, AFTER AIR BALANCING, TO PROVIDE DESIGN QUANTITIES.6. ADJUST SYSTEMS TO PROVIDE SPECIFIED PRESSURE DROPS AND FLOWS THROUGH HEAT TRANSFER ELEMENTS PRIORTO THERMAL TESTING. PERFORM BALANCING BY MEASUREMENT OF TEMPERATURE DIFFERENTIAL IN CONJUNCTION WITHAIR BALANCING.
B. CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADES AND NOTIFY 360 ENGINEERING, INC. IF ANY CONFLICTS OCCUR.
C. THERMOSTAT LOCATIONS AND HEIGHTS TO BE COORDINATED WITH BUILDING MANAGEMENT, VERIFIED BY THE ENGINEER.CONTRACTOR TO CALIBRATE ALL THERMOSTATS SHOWN ON THIS PLAN. IT SHALL BE THE GENERAL CONTRACTOR'SRESPONSIBILITY TO ENSURE THAT ALL EXISTING THERMOSTATS REMAIN INTACT DURING DEMOLITION. HEATING THERMOSTATSMUST REMAIN OPERATIONAL AT ALL TIMES. IF REQUIRED FOR BETTER PROTECTION, THERMOSTATS MAY BE TEMPORARILYMOUNTED IN THE CEILING PLENUM DURING DEMOLITION.
D. PROVIDE VOLUME DAMPERS AT ALL DIFFUSER TAKEOFFS.
E. ALL TAKEOFFS, RUNOUTS, AND FLEX DUCTWORK TO DIFFUSERS SHALL BE THE SAME SIZE AS DIFFUSER INLET UNLESSOTHERWISE NOTED.
F. MECHANICAL CONTRACTOR TO CHECK OPERATION AND CONDITION OF ALL EXISTING MECHANICAL EQUIPMENT WITHIN THECONFINES OF THIS SPACE AND PREPARE A WRITTEN LIST OF ANY DEFICIENCIES IN EQUIPMENT OPERATION OR CONDITION. LIST SHALL BE SUBMITTED TO OWNER TWO WEEKS AFTER THE AWARD OF THE CONTRACT.
G. THERMOSTAT CONTROL LINES SHALL BE SUPPORTED AT INTERVALS NOT TO EXCEED 4'0".
H. PROVIDE EXTERNAL INSULATION ON ALL NEW RIGID ROUND DUCTWORK.
I. PROVIDE ACCESS DOORS IN DUCTWORK AS REQUIRED FOR ACCESS TO FIRE DAMPERS, FIRE/SMOKE DAMPERS, OR ANY OTHERMECHANICAL EQUIPMENT REQUIRING MAINTENANCE OF SERVICE.J. ALL PIPE AND DUCT PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED PER 2015 IBC.
MT
P
Thermostat heights tocomply with reachranges in ICCA117.1-2009 308.
(R)
(R)
(R)
(R)
(R)
(R)(R)
(E)
(E)
(E)
PITKIN COUNTY
COURTHOUSE REMODEL
PITKIN COUNTY, CO
506 E Main St St 300, Aspen, CO 81611
No. Description Date1 Addendum #2 05-23-2019
INTERCEPTING CONDUITS IN THE VISITING JUDGE'S CHAMBERS ANDRE-ROUTING AROUND THE LOWER LIFT LOBBY BACK INTO COURTROOM 3.
3 EXISTING ELEVATOR EQUIPMENT TO BE REPLACED WITH NEW IN SAMELOCATION. NEW ELEVATOR ELECTRICAL CHARACTERISTICS (3OHP) ARESAME AS EXISTING (30HP). CONTRACTOR SHALL MAINTAIN EXISTING FIREALARM CONNECTIONS AND EXISTING POWER CIRCUITRY IF VERIFIED TOMATCH NEW. REFER TO ELEVATOR EQUIPMENT INFORMATION INMECHANICAL SCHEDULE FOR MORE INFORMATION.4 EXISTING CAB LIGHT DISCONNECT IS A TOGGLE SWITCH AND SHALL BEREPLACED WITH FUSED DISCONNECT. REMOVE EXISTING TOGGLE SWITCHAND MAINTAIN EXISTING CIRCUITRY FOR CONNECTION TO NEWDISCONNECT SWITCH IN NEW WORK.5 CONTRACTOR SHALL MAINTAIN EXISTING FUSED DISCONNECT IF VERIFIEDTO BE A 150A FUSE IN 200A3P DISCONNECT. OTHERWISE REPLACE WITHNEW IN SAME LOCATION. VERIFY FEED TO DISCONNECT MATCHES NEWFEEDER PER EQUIPMENT INDICATED IN MECHANICAL EQUIPMENTSCHEDULE.
1
620.22 Branch Circuits for Car Lighting, Receptacle(s),Ventilation, Heating, and Air-Conditioning.(A) Car Light Source. A separate branch circuit shall supplythe car lights, receptacle(s), auxiliary lighting power source, andventilation on each elevator car. The overcurrent device protectingthe branch circuit shall be located in the elevator machineroom or control room/machinery space or control space.Required lighting shall not be connected to the load side ofa ground-fault circuit interrupter
176 SF
BOILER01A
72 SF
MECH/ELEC02D
35 SF
JAN.00A 98 SF
STORAGE00B
332 SF
HOLDING06
143 SF
CONF. RM08
87 SF
JUDGE RR14
715 SF
COURTROOM 305
53 SF
HALL16
13B
05A
17
06
NF6
NF6
NF6NF6NF6
NF3
NF8UP
UP
5' - 0"
UP
NEW ACCESSIBLE CONC RAMP. MAX SLOPE 1:12. RE: CIVIL
102 SF
WOMEN00C
113 SF
MEN00D
INFILL <E> OPENING, RE:STRUCT.
M.O.4' - 1"5' - 0"
6' - 2 1/2"
A9.91
A9.82
A4.02
47 SF
STORAGE15
70 SF
SECURE HALL13
49 SF
ELEV. MECH.00E
A7.31
.
615 SF
HALL00
110 SF
HALL09
59 SF
HALL10
408 SF
VISITING JUDGE'SCHAMBERS04
49 SF
HALL05A
<N> RAISED PLATFORM FOR JUDGE'S BENCH
06A
06B
85 SF
ATTORNEY06A 20 SF
MECH.06B
4' - 6"
NF6
NF9NF9 NF9 NF9
3
49 SF
JURY RR07
07
116 SF
OFFICE 102C
SF
ST.2 55 SF
ELEV.11
UP
B
B
A
A C
F
A
C
A7.51
A9.121
F
C
ALIGN
O.2""
13A
08
A4.01
10' - 6
"
1/2"
4' - 5 1/2"
3' - 11 1/2"
12' - 5"
6' - 1
1
1
/
2
"
5' - 8"
9 1/2
"
5"
R.O.3' - 2"
5"
D
100' - 0"
100' - 0"
76 SF
LOWER LIFT LOBBY17
A
I
NF10 NF10
04
12
M.O.3' - 4"
3' - 5"
R.O.3' - 2"
1' - 5"
R.O.3' - 2"
1' - 5"
1' - 6"
10' - 0"
R.O.3' - 2"
8 1/2"
R.O.3' - 2"
R.O.3' - 2"
R.O.
1' - 0"1' - 0"
ALIGN F.O. <N> WALL WITH CENTER LINE OF <E> COLUMN.
NF15
00B
00A
00E
05
04A00D00C
02D
01A
HOLD3' - 6"
16
F
D
VERTICAL INTERIOR ROOF DRAIN TO REMAIN
D
NF20
NF20
06B
05A 05B 05C
05D
05E
06CNF6
3' - 6"
9 1/4"
7"
UP
RTICAL GRAB BLE STALL & PIPE
M.O.3' - 4"
A0.25
NF26
NF27NF28NF29
05B 05C
15
14
B
NF9 NF9NF9
NF9
NF9
NF9 NF9NF9
C
NF9
NF9
A
AA
A
G
GNF15
NF37
REF STRUCTURAL FOR MATERIAL AND SIZING FOR STRUCTURAL ELEMENTS IN WALL TYPA AT NEW LIFT STRUCTURE
SIM
SIM
E
1
LEGEND
<E> WALL
NEW WALL
NEW DOOR
NEW FLOOR STRUCTURE, RE: STRUC
REPAIR CONCRETE SLAB. PROVIDE CONSISTENT FLOOR LEVEL PRIOR TO INSTALLING NEW FLOOR FINISH.
FLOOR ELEVATION
KEYNOTE
DOOR TAG
WALL TYPE
#
-
101
X
GENERAL NOTES1. PATCH AND REPAIR ALL FINISHES AFFECTED BY CONSTRUCTION. MATCH ADJACENT FINISH.2. COORDINATE REUSE, SALVAGE, OR DISPOSAL OF ALL DEMO ITEMS WITH OWNER.3. REMOVE & SALVAGE <E> WINDOW TREATMENTS. COORDINATE REINSTALLATION WITH PITKIN COUNTY/ 9TH JUDICIAL DISTRICT.4. FURNITURE BY OTHERS. SHOWN FOR REFERENCE.5. PITKIN COUNTY TO BE RESPONSIBLE FOR REMOVING / RELOCATING ALL <E> FURNITURE.6. REFERT TO M, P, E, & S SHEETS FOR ADDITIONAL INFORMATION.7. REFER TO FINISH PLANS AND RCPS FOR ADDITIONAL INFORMATION.8. ALL REPOSITIONED COURTROOM FURNITURE TO PROVIDE 30" CLEAR.9. REMOVE AND SALVAGE <E> SIGNAGE (FLAGS AND WALL MOUNTED). MODIFY FOR <N> ROOM NAMES. INSTALL <N> TO MATCH <E> WHERE NEEDED.10. REFER TO A 9.7 FOR ADDITIONAL CLERESTORY.
PROVIDE SMOOTH AND FLUSH FINISH MATCH <E> ADJACENT FURRING ANDFINISH.NF20 INSTALL <N> HIGH IMPACT RESISTANTGYP. BD. WALL FINISH ON <E> FURRIN INSTALL <N> FURRING (TO MATCH <E> AS NEEDED FOR <N> OPENING ATEXISTING ELEVATOR CORE.NF26 THE CAB HAS THREE SETS OFCONTROLS. (2) AT STANDARD HEIGHT REAR AND FRONT OF CAB AND A THIR SET OF CONTROLS MOUNTED AT 29" A REMOVE THIRD SET OF CONTROLS.UPDATETHE CONTROL OPTIONS TOINCORPORATE <N> CALL BUTTON TO < SIDE OF GARDEN LEVEL, ANDSECURE/DESIGNATED ACCESS FORIN-CUSTODIES AND STAFF.NF27 REMOVE <E> VINYL TILE FLOOR.PROVIDE <N> CARPET TILE FLOORFINISH. PROVIDE <N> INTERIOR CABFINISH ON ALL 4 WALLS. PROVIDE <N>CEILING FINISH AND LIGHTING. REMOV <E> AUXILIARY PANEL.NF28 PROVIDE CAB CONTROLS VIA CARDACCESS TO ALLOW FOR LOCKOUT FO EITHER JUDGE OR IN-CUSTODYTRANSPORT.NF29 PROVIDE VERTICAL ACCESSIBLE GRA BAR IN <E> RESTOOM. RE: A 9.3NF37 PROVIDE <N> PLUMBING CHASE FOR < ROOF DRAIN WITH 6" MIN INTERIORCLEAR. SIZE OF PIPE TO BE CONFIRME VIA DESIGN BUILD.
1
Per the code summaryon G0.4, the occupantload of the gardenlevel courtroomexceeds 50, correctdoor swing so thatdoors swing in thedirection of egresstravel per 2015 IEBC805.4.2
176 SF
BOILER01A
72 SF
MECH/ELEC02D
35 SF
JAN.00A 98 SFSTORAGE00B
332 SF
HOLDING06
143 SF
CONF. RM08
87 SF
JUDGE RR14
715 SF
COURTROOM 305
53 SF
HALL16
372 SF
JURY DELIBERATION03
13B
01
05A
17
06
NF6
NF6
NF6NF6NF6
NF3
UPUP
UP
UP
102 SF
WOMEN00C
113 SF
MEN00D
INFILL <E> OPENING, RE:STRUCT.
M.O.4' - 1"5' - 0"
6' - 2 1/2"
5"
A9.82 47 SF
STORAGE15
70 SF
SECURE HALL13
49 SFELEV. MECH.00E
55 SF
VEST.03A
122 SF
ATTORNEY01
615 SF
HALL00
110 SF
HALL09
59 SF
HALL10
408 SF
VISITING JUDGE'SCHAMBERS04
49 SF
HALL05A
06A
06B
85 SFATTORNEY06A
4' - 6
"
NF6
NF9NF9 NF9 NF9
03
JURY RR07
07
89 SF
ALPINE LEGAL02E
116 SF
OFFICE 102C103 SF
OFFICE 202B
197 SF
BREAK ROOM02A
85 SF
VEST.02
02C02B
02A
02E
DW
55 SF
ELEV.11
UP
UP
A
A
B
B
A
A
A
A
A
A
C
F
A
C
<N> CABINET
A7.51
F
C
ALIGN
9' - 2"
R.O.3' - 2"5 1/2"
13A
08
A4.0113' - 4 1/2"
2' - 10"
8' - 2"
10' - 6
"
8' - 1 1/2"
R.O.3' - 2"4' - 5 1/2"
3' - 11 1/2"
6' - 1
1
"
12' - 5"
6' - 11 1
/
2
"
5' - 8"
9 1/2
"
5"
R.O.3' - 2"
5"
13' - 3"
7"
D
ALIGN
100' - 0"
100' - 0"
A9.21
A
I
NF10 NF10
04
12
00
09
M.O.3' - 4"
3' - 5"
R.O.3' - 2"
1' - 5"
R.O.3' - 2"
1' - 5"
R.O.3' - 2"
8 1/2"
R.O.3' - 2"
R.O.3' - 2"
HOLD1' - 0"R.O.3' - 2"R.O.'3' - 2"
R.O.3' - 2"1' - 4"
R.O.3' - 2"
R.O.3' - 2"
1' - 0"1' - 0"
ALIGN F.O. <N> WALL WITH CENTER LINE OF <E> COLUMN.
NF15
1' - 6"
FIN.4' - 6"
00B
00A
00E
05
04A00D00C
02D
01A
HOLD3' - 6"
16
F
18
REF.
D
D
NF20
NF20
0
05A 05B 05C
0
0
0
06A06D06E
NF6
NF6NF6NF6
3' - 6"
9 1/4"
7"
UP
A9.26
INSTALL <N> SCREEN OVER CONDUIT INSTALL <N> SCREEN OVER CONDUIT
PROVIDE <N> VERTICAL GRAB BAR AT ACCESSIBLE STALL & UNDERCOUNTER PIPE PROTECTION
M.O.3' - 4"
NF26
NF27NF28NF29
05B 05C
15
14
B
NF9 NF9NF9
NF9
NF9
NF9 NF9NF9
C
A
AA
A
G
GNF15
INSTALL <N> 2" THICK CONC "BENCH" OVER FOUNDATION
INSTALL <N> 4X4 STL ANGLE TO SUPPORT CONC BENCH ENDEGRESS STAIR FOUNDATION, RE: STRUC
NF37
CONTRACTOR SHALL CONNECTNEW INTERNAL ROOF DRAIN TO NEW STORM SEWER: REF CIVIL
REF STRUCTURAL FOR MATERIAL AND
SIM
SIM
D
E
1
1
PROVIDE MINIMAL WALL PENETRATION INVERT OF 7903.83' TO ACHIEVE A MINIMUM 1% SLOPE TO STORM SEWER TIE-IN
1
Per 2015 IEBC 705, 705.2, thisalteration affects the area of primaryfunction and therefore the toilet facilitiesserving the area of primary functionshall be accessible to the maximumextent that is technically feasible.Revise door widths to provide clearopening width of 32 inches minimum.Provide an accessible toiletcompartment, grab bars and undercounter pipe protection in the men'srestroom.
08/21/2019
File Name: 2019.06.14 Pitkin Permit - Architectural.pdf
Author: bonniem
Subject: PlanCheck
Color:
Page Label: A1.1 MAIN LEVEL FLOOR PLAN
Per 2015 IEBC 705, 705.2, this
alteration affects the area of
primary function and therefore
the toilet facilities serving the
area of primary function shall be
accessible to the maximum
extent that is technically feasible.
Revise door widths to provide
clear opening width of 32 inches
minimum. Provide an accessible
toilet compartment, grab bars
and under counter pipe
protection in the men's restroom.
File Name: 2019.06.14 Pitkin Permit - Architectural.pdf
Author: bonniem
Subject: PlanCheck
Color:
Page Label: A5.0 DOOR SCHEDULE
1. Confirm that the following
2'10" doors will provide the
minimum clear width of 32" per
2015 IBC 1010.1.1: 00, 04, 100,
105C, 108A, 113, 114, 202C,
203.
File Name: 2019.06.14 Pitkin Permit - Architectural.pdf
Author: bonniem
Subject: PlanCheck
Color:
Page Label: A5.0 DOOR SCHEDULE
Correct the following doors to
provide the required 32" clear
width per 2015 IBC 1010.1.1:
108B, 108C
File Name: 2019.06.14 Pitkin Permit - Architectural.pdf
Author: bonniem
Subject: 3/16" Scale
Color:
Page Label: A7.3 ENLARGED PLANS AT NEW LIFT ENTRY
3'-5"
File Name: 2019.06.14 Pitkin Permit - Architectural.pdf
Author: bonniem
Subject: PlanCheck
Color:
Page Label: A7.3 ENLARGED PLANS AT NEW LIFT ENTRY
Side door on the lift requires a
clear opening width of 42"
minimum. ICC A117.1-2009
410.2.1
IT106
FILE/COPY102D STORAGE112
PROBATION108
PROBATION RR108D
OFFICE 1108E
OFFICE 2108C
OFFICE 3108B
WAITING108A
CLOSET108F
HALL105
OFFICE 2105B
MEETINGROOM105C
CLERKS102
WAITING/SELF HELP102A
CLERKWORKSTATIONS103
FAMILY COURT/COLLECTIONS102B OFFICE 1104
108E
104
NF3
DN
DN
<N> CONC. RAMP, MAX. SLOPE 1:12. RE: CIVIL
MEN113 WOMEN114
11' - 9"
10' - 11
"
ALIGN
10' - 0 1/2"6' - 7
"
R.O.3' - 2"7"
1' - 4"
UP UP
DN
DN
A9.92
HALL100
4' - 3 1/2"
102B
TRANSACTION COUNTER : REF 5:A9.3
SECURITYSCREENING115
VEST.100A
EST.10
HALL103AELEV.111
INFORMAL MTG105A
B
A
F
A
AA
A
<N> ACCESSIBLE RAILINGS<N> ACCESSIBLE RAILINGS
ALIGN
101C101B
OFFICE 1101B
OFFICE 2101C
WITNESSWAITING101D
DA OFFICE101
OFFICE 4101E
101EAAA101D
OFFICE 3101F
101F
A
WAITING101A
OPEN TO BELOW
A9.6
2
A9.6
3
A9.4
4
A9.4
5
A9.34
A9.3 5
V.I.F.15' - 7"
10 1/2"
V.I.F.
4' - 10 1/2"
1"HOLD5' - 0"1"
V.I.F.0"
1' - 0"
V.I.F.11' - 4"
9' - 6"
9' - 11 1/2"
6' - 8"
4 1/2"ALIGN
A
A
A9.41108
ALIGN
2A9.3
A
ALIGN
R.O.3' - 2"
4' - 0 1/2"
ALIGN
R.O.3' - 2"
R.O.3' - 2"
6 1/2"R.O.3' - 2"
R.O.3' - 2"
R.O.3' - 2"
R.O.3' - 2"
F.4"R.O.3' - 2"1' - 0"HOLD1' - 6"
ALIGN
7' - 1"
A
110
100A
100B
6"6"
NF14
E
A9.61
152
C
102D
115102102A
106 105B
105C
108C
108B
100C
101A 113
100
112
114
108F
108A
NF19A4.04
X RAY 73" x 47"
MAGNETOMETERS 36" x 28"DEMOUNTABLE GLASS PARTITION 6' HT
1' - 6"R.O.3' - 2"102C
A9.71
1' - 10"
4' - 4"1' - 8"
4' - 4"1' - 6"
2' - 7"2' - 2"
H H
H
PROVIDE <N> VERTICAL GRAB BAR AT ACCESSIBLE STALL & UNDERCOUNTER PIPE PROTECTION
WALL-MOUNTED SWING SECURITY EXIT GATE
A4.03
A4.06
108D
103A
6
NF25
NF23
1' - 4 1/2"1' - 0 1/2"
E
SECUR
I
T
Y
STAF
F
MIN3' - 0"
MIN3' - 6"
A4.07
A4.08
A9.31
3A9.3
A9.7
5
MIN.1' - 0"
4
7' - 0"
H
1' FLOOR
A
NF30
NF30
TAIN 48 INCHES CLEAR MANUEVERING SPACE AT H SIDES OF OPENING.ENTIRE DEPTH OF MASONRY WALL.3.VERIFY 32 INCHES CLEAR OPENING4.MAINTAIN 48 INCHES CLEAR MANUEVERING SPACE AT BOTH SIDES OF OPENING.
1' - 11"
2' - 10"
HOLD
3' - 10 1/2"
ALIGN
V.I.F.' - 4"
V.I.F.1"
A
E
AA
NF31 NF32
NF32
NF32 NF32
NF33
NF34
A
A
A
AA9.7 76
3' - 5"
101
REF.
1
NF37
LEGEND
<E> WALL
NEW WALL
NEW DOOR
NEW FLOOR STRUCTUR STRUC
REPAIR CONCRETE SLA PROVIDE CONSISTENT F LEVEL PRIOR TO INSTAL NEW FLOOR FINISH.
FLOOR ELEVATION
KEYNOTE
DOOR TAG
WALL TYPE
#
-
101
X
GENERAL NOTES1. PATCH AND REPAIR ALL FINISHES AFFEC CONSTRUCTION. MATCH ADJACENT FINI 2. COORDINATE REUSE, SALVAGE, OR DISP DEMO ITEMS WITH OWNER.3. REMOVE & SALVAGE <E> WINDOW TREA COORDINATE REINSTALLATION WITH PIT JUDICIAL DISTRICT.4. FURNITURE BY OTHERS. SHOWN FOR RE 5. PITKIN COUNTY TO BE RESPONSIBLE FO RELOCATING ALL <E> FURNITURE.6. REFERT TO M, P, E, & S SHEETS FOR ADD INFORMATION.7. REFER TO FINISH PLANS AND RCPS FOR INFORMATION.8. ALL REPOSITIONED COURTROOM FURNI 30" CLEAR.9. REMOVE AND SALVAGE <E> SIGNAGE (F MOUNTED). MODIFY FOR <N> ROOM NAM TO MATCH <E> WHERE NEEDED.10. REFER TO A 9.7 FOR ADDITIONAL CLERE
N
MIRRORED FILM APP GLASS. REMOVE DOO INFILL HOLE WHERE HARDWARE REMOVE FLUSH FINISH WITHSURROUNDING WD, P MATCH.NF23 FIX DOOR IN OPEN PO NF25 CUT THROUGH <E> S FOUNDATION WALL. P <N> DOOR ACCESS T NORTH OF THE <E> E NF30 PROTECT <E> SAFE D REMAIN IN PLACE.NF31 ALIGN <N> WALL WIT COLUMNS.NF32 <N> CLERESTORY WI ABOVE. RE: INT. ELEV NF33 <E> COLUMN TO REM NF34 REINSTALL SALVAGE MILLWORK ON <N> W PROVIDE <N> WD AC PANEL.NF37 PROVIDE <N> PLUMB FOR <N> ROOF DRAIN MIN INTERIOR CLEAR PIPE TO BE CONFIRM DESIGN BUILD.
DRAWINGS BASED ON FLO PROVIDED BY PITKIN COUN
0 4' 8
1
Per 2015 IEBC 705, 705.2, thisalteration affects the area of primaryfunction and therefore the toilet facilitiesserving the area of primary functionshall be accessible to the maximumextent that is technically feasible.Revise door widths to provide clearopening width of 32 inches minimum.Provide an accessible toiletcompartment, grab bars and undercounter pipe protection in the men'srestroom.
S 1. Confirm that the following 2'10" doors will
provide the minimum clear width of 32" per
2015 IBC 1010.1.1: 00, 04, 100, 105C,
108A, 113, 114, 202C, 203.
HIS
Correct the following doors to provide the
required 32" clear width per 2015 IBC
1010.1.1: 108B, 108C
LIFT
3'
-
5
"
<N> POST MOUNTE AUTOMATIC ACCES DOOR OPENER BUT LOCATION (EXTERIO
NEW WALL MOUNTE AUTOMATIC ACCES DOOR OPENER BUT LOCATION (INTERIO
PRE-FINISHED GATE ASSEMBLY BY LIFT INSTALLED BY G.C.
PRE-FINISHED LIFT ASSEMBLY - INSTAL BY G.C.
T-SHAPED TURNING CLEARANCE
<E> WINDOW TO
DOOR PROVIDED B MFG INSTALLED BY
CLOSET108F
3A7.3
LIFT5
A7.3
TO BE REMOVED AND SALVAGED
EXISTING DOOR LOCATION
(V.I.F.)
1' - 7"NEW CLR OPENING
4' - 9"
,<E> STAIR AND
<E> ENTRY VESTIBULE
OPEN TO BELOW
(V.I.F.)
4' - 8"
(V.I.F.)
5' - 5 1/2"
(V.I.F.)
1' - 10"
ADA CLEAR FLOOR SPACE
<E> WINDOW AND FRAME TO REMAIN
FIN. TO STUD4' - 0" (V.I.F.)
<N> STRUCTURAL FLOOR AT LIFT PLATFORM LOCATION
<N> ENCLOSURE AT LIFT WALL
PRE-FINISHED LIFT INSTALLED BY G.C.
<E> MECHANICAL DUCT TO REMAIN
NOTE: NEW WALL FRAMING AT LIFT LOCATION SHALL BE (1) HOUR RATED (SHOWN WITH DIAGONAL CROSS HATCH)
STEEL FRAMING: GA FILE NO WP1072WOOD FRAMING: GA FILE NO WP 2510
MAIN LEVEL110' - 3 5/8"
LOOR STRUCTURE AND LIFT SO ATFORM OF LIFT ALIGNS WITH BEYOND
LL CONSTRUCTION WITH RESISTANT GYP. BOARD ON PUBLIC SIDE OF LIFT URE
<N> CARPET FINISH ON <N> ITH 3/4" T&G PLYWD -ALIGN <N> WITH <E> MAIN FLOOR
LL ENCLOSURE
F <N> OPENING BEYOND
SONRY WALL TO REMAIN, RE:
OR TO REMAIN
D BASE - PT TO MATCH <E>
2
Side door on the liftrequires a clearopening width of 42"minimum. ICCA117.1-2009 410.2.1
08/21/2019
File Name: 2019.06.14 Pitkin Permit - Architectural.pdf
Author: bonniem
Subject: PlanCheck
Color:
Page Label: A9.2 INTERIOR ELEVATIONS
Knee and toe clearances must
be provided at the jury
deliberation sinks. ICC
A117.1-2009 606.2
File Name: 2019.06.14 Pitkin Permit - Architectural.pdf
Author: bonniem
Subject: PlanCheck
Color:
Page Label: A9.2 INTERIOR ELEVATIONS
A parallel approach to the sink is
required when knee/toe
clearances are not provided.
ICC A117.1-2009 606.2
exception 1. The dishwasher in
the open position cannot
encroach into the clear floor
space of the sink 804.5.3.
File Name: 2019.06.14 Pitkin Permit - Architectural.pdf
Author: bonniem
Subject: PlanCheck
Color:
Page Label: A9.7 INTERIOR ELEVATIONS - DA
A parallel approach to the sink is
required when knee/toe
clearances are not provided.
ICC A117.1-2009 606.2
exception 1.
File Name: 2019.06.14 Pitkin Permit - Architectural.pdf
Author: bonniem
Subject: PlanCheck
Color:
Page Label: G0.1 COVER SHEET
Per information provided on the
asbesos verification checklist
this project requires an asbestos
test. Provide an asbestos test
report that includes the following:
1.Inspector’s narrative including
sampling locations
2. Inspector’s certificate
3. Lab data
If asbestos is found, a final air
clearance report must be
provided prior to building permit
issuance.
File Name: 2019.06.14 Pitkin Permit - Architectural.pdf
Author: bonniem
Subject: PlanCheck
Color:
Page Label: G0.1 COVER SHEET
The special inspection
agreement needs to be
completed and signed by all
parties prior to permit issuance.
A9.22 1' - 11 1
/
2
"
2' - 6"
3"
2' - 1"
2A9.11Sim
FINISHED FACE PANEL
<E> COLUMN TO REMAIN, LOCATION V.I.F.
30" X
4
8
"
CLEA
R
S
P
A
C
E
(E) SIGNAGE, MODIFY TO ACCOMODATE (N) ROOM NAME, COMPLY W/ ADA
PROVIDE <N> OR RELOCATED FLAG SIGNAGE AT THE FOLLOWING ROOMS:• 05• 102A• 105C• 108A• 101A• 201• 203
PROVIDE <N> OR RELOCATED WALL SIGNAGE TO MATCH EXISTING AT ALL ROOMS.
SOLID SURFACE COUNTERTOP WITH INTEGRAL 4" BACKSPLASH
2A9.11SimSB30
FINISHED FACE PANEL; BEHIND COLUMN
<E> COLUMN TO REMAIN, LOCATION V.I.F.
FILLERFILLER
BC30 BC30 DW24 SB36 3'-0" MIN. CLR
2' - 1"DW REF.
3A9.11Sim1A9.11Sim
2' - 10"
2' - 3"
BC36BC36SB36DW24REF.
ADJACENT STONE
3A9.11Sim 1A9.11Sim
FILLER; SCRIBE TO ADJACENT STONE
CABINET LEGEND
BC =BASE CABINETSB=SINK BASE CABINETDW=DISHWASHERTC=TALL CABINETWC=WALL CABINETREF=REFRIGERATOR
BC15 BC30
2' - 10"
SOLID SURFACE COUNTERTOP WITH INTEGRAL 4" BACKSPLASH
2A9.11Sim
FINISHED END PANELS A9.251' - 3"
2' - 6"
1"2' - 0 1/2"
2A9.11Sim
FINISHED END PANEL
30" X 48
"
CLEAR
S
P
A
C
E
FINISHED END PANEL
Project Number
DateDrawn byChecked by
COPYRIGHT 2019ANY UNAUTHORIZED USE OF THESE DOCUMENT IS PROHIBITED WITHOUT THE WRITTEN CONSEN OF:ANDERSON HALLAS ARCHITECTS, P.C.
PLANNING
Issue
715 FOURTEENTH STREETGOLDEN, COLORADO 80401(303) 278-4378FAX (303) 278-0521
Scale AS NOT
A9.2
INTERIORELEVATIONS
20179
PITKIN COUNTY
COURTHOUSE REMODEL
PITKIN COUNTY, CO
5/2/ LW RAS/NA
506 E Main St St 300, Aspen, CO 81611
PER
1/2" = 1'-0"1JURY DELIB. 03 ENLARGED PLAN DRAWINGS BASED ON FLOOR PLANS PROVIDED BY PITKIN COUNTY. CONTRACTOR TO NOTIFY ARCHITECT OF ANY DEVIATIONS FROM ACTUAL FIELD CONDITIONS, PRIOR TO COMMENCING WITH WORK.
0 2' 4'
1 1/2" = 1'-0"EXISTING SIGNAGE 1/2" = 1'-0"2JURY DELIB. 03 INTERIOR ELEVATION EAST
1/2" = 1'-0"6BREAK RM 02A ENLARGED PLAN 1/2" = 1'-0"7BREAK RM 02A INTERIOR ELEVATION SOUTH
1/2" = 1'-0"5JURY DELIB. 204 INTERIOR ELEVATION WEST 1/2" = 1'-0"4JURY DELIB. 204 ENLARGED PLAN
1
No. Description Dat 1 ADDENDUM 01 4/26/20
Knee and toeclearances must beprovided at the jurydeliberation sinks. ICC A117.1-2009606.2
A9.2
7
BC30 BC30 DW24 SB36 3'-0" MIN. CLR
2' - 1"DW REF.
3A9.11
Sim1A9.11
Sim
30" X 48" CLEAR SPACE
2' - 1
0
"
WC24 WC30 WC30C36
BC36BC3636DW24
SOLID SURFACE COUNTERTOP WITH INTEGRAL 4" BACKSPLASH; SCRIBE TO ADJACENT STONE
3A9.11Sim 1A9.11
Sim
FILLER; SCRIBE TO ADJACENT STONE
FILLER; SCRIBE TO ADJACENT STONE
BC15 BC30
2' - 1
0
"
SOLID SURFACE COUNTERTOP WITH INTEGRAL 4" BACKSPLASH
2A9.11Sim
FINISHED END PANELS A9.251' - 3
"
2' - 6
"
1"2' - 0 1/2"
2A9.11Sim
FINISHED END PANEL
30" X
4
8
"
CLEA
R
S
P
A
C
E
FINISHED END PANEL
Anderson HallasArchitects, PCARCHITECTUREHISTORIC PRESERVATION
COPYRIGHT 2019ANY UNAUTHORIZED USE OF THESE DOCUMENTS IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF:ANDERSON HALLAS ARCHITECTS, P.C.
PLANNING715 FOURTEENTH STREETGOLDEN, COLORADO 80401(303) 278-4378FAX (303) 278-0521
PITKIN COUNTY
OURTHOUSE REMODEL
PITKIN COUNTY, CO
506 E Main St St 300, Aspen, CO 81611
1/2" = 1'-0"6 BREAK RM 02A ENLARGED PLANA INTERIOR ELEVATION SOUTH
LIB. 204 INTERIOR ELEVATION WEST 1/2" = 1'-0"4 JURY DELIB. 204 ENLARGED PLAN
A parallel approach tothe sink is requiredwhen knee/toeclearances are notprovided. ICCA117.1-2009 606.2exception 1. Thedishwasher in theopen position cannotencroach into the clearfloor space of the sink804.5.3.
WC36 WC12WC36
BC24BC24SB36
SOLID SURFACE COUNTERTOP WITH INTEGRAL 4" BACKSPLASH
1A9.11
Sim2A9.11
Sim
CABINET LEGE
BC =BASE CABINETSB=SINK BASE CABINET
DW =DISHWASHER
TC =TALL CABINETWC=WALL CABINET
REF =REFRIGERATOR
A9.7
2
3
BC24
TC30
SB36 2' - 0" CLR.BC24
1' - 10"
1' - 10"
2A9.11
Sim 1A9.11
Sim
1A9.11Sim30" X 48" CLEAR SPACE
REF.2' - 0"
APT. SIZE REF. PROVIDED BY OWNER
EQ EQ
101F
101F
DRAWINGS BASED ON FLOO PROVIDED BY PITKIN COUNTY TO NOTIFY ARCHITECT OF AN FROM ACTUAL FIELD CONDIT COMMENCING WITH WORK.
0 2'
= 1'-0"101 INTERIOR ELEVATION NORTH 1/2" = 1'-0"1DA 101 ENLARGED PLAN
1/2" = 1'-0"4DA OFFICE 101 NORTH
A parallel approach tothe sink is requiredwhen knee/toeclearances are notprovided. ICCA117.1-2009 606.2exception 1.
And
Arc
AR
HISTORI
COPYRIGHT 2019ANY UNAUTHORIZ IS PROHIBITED W OF:ANDERSON HALL
P
715 FO GOLDE
FA
Per information provided on the asbesos verification
checklist this project requires an asbestos test.
Provide an asbestos test report that includes the
following:
1.Inspector’s narrative including sampling locations
2. Inspector’s certificate
3. Lab data
If asbestos is found, a final air clearance report must
be provided prior to building permit issuance.
An A
A
HISTOR
COPYRIGHT 20 ANY UNAUTHOR IS PROHIBITED OF:ANDERSON HA
715 GOL
The special inspection agreement needs to be
completed and signed by all parties prior to permit
issuance.
08/21/2019
File Name: 2019.06.14 Pitkin Permit - Architectural.pdf
Author: bonniem
Subject: PlanCheck
Color:
Page Label: G0.3 GENERAL INFORMATION / EGRESS
PLAN
Provide the full installation
instructions from the Gypsum
Manual for WP 1072, WP 3510,
WP 6800, FC3510 in the plan
set for reference at inspection.
NEW ACCESSIBLE ENTRANCE
MAX TRAVEL DISTANCE: 57'
1231 / 40SF / OCC= 31 OCC
DELAYED EGRESS DOOR. PROVIDE WEATHER PROOF SIGNAGE: PUSH UNTIL ALARM SOUNDS, DOOR CAN BE OPENED IN 15 SECONDS
FEC
FEC
AX TRAVEL DISTANCE: 115'
EC FEC
FECFEC
FEC
FEC
MAX TRAVEL DISTANCE: 125'
FEC
LEGEND
FEC
EGRESS PATHEGRESS DOOR WITH EXIT SIGNAGE
FIRE EXTINGUISHER CABINETEXIT SIGNAGE, RE: ELEC
TRAVEL DISTANCEBUILDING DIAGONAL DISTANCESIGNAGE: EMERGENCY EXIT ONLY, ALARM WILL SOUND UNLESS ACTIVATED BY KEY CARD
WALL TYPES X
A
TYPE GRAPHIC REPRESENTATION FIRE RATING
NA5/8" GWB5 1/2" WD STUDS AT 16" OCFULL DEPTH MINERAL WOOL ACOUSTIC INSULATION5/8" GWB6 3/4"
B NA5/8" GWB5 1/2" WD STUDS AT 16" OCFULL DEPTH MINERAL WOOL ACOUSTIC INSULATION3/8" PORCELAIN TILE, 5/8" CTBB / 5/8" MOISTURE RESISTANT GWB ABOVE6 3/4"
C: SECURE WALLS NA1/2" PLYWOOD5 1/2" WD STUDS AT 16" OCFULL DEPTH MINERAL WOOL ACOUSTIC INSULATION1/2" PLYWOOD SHEATHING
RR SIDE 5/8" IMPACT RESISTANT GWB
5/8" IMPACT RESISTANT GWB
D: PLUMB. CHASE WALLS 5 1/2" WD STUDS AT 16" OCFULL DEPTH MINERAL WOOL ACOUSTIC INSULATION3/8" PORCELAIN TILE, 5/8" CTBB / 5/8" MOISTURE RESISTANT GWB
7 3/4"
6 1/8"
RR SIDE
2 1/8"E:
NA
NA
5/8" GWB1 1/2" WD FURRING AT 16" OCFULL DEPTH MINERAL WOOL ACOUSTIC INSULATION
PUBLIC
SECURE
F: ACOUSTIC ISOLATION NA
5/8" GWB5 1/2" STAGGERED WD STUDS AT 8" OC
FULL DEPTH MINERAL WOOL ACOUSTIC INSULATION RUNNING CONTINUOUSLY IN BETWEEN STUDS5/8" GWB
7 3/4"1" SPACE IN BETWEEN STUDS AND GWB, BOTH SIDES
G: MASONRY INFILL NAMASONRY INFILL, RE: STRUCT.WD STUD S AT 16"O.C., ADJUST FURRING TO PROVIDE FLUSH FINISH
5/8" IMPACT RESISTANT GWB
5/8" IMPACT RESISTANT GWB
VARIES
WD STUD S AT 16"O.C., ADJUST FURRING TO PROVIDE FLUSH FINISH
H: SHAFT WALLGA FILE #:WP 6800
1" X 24" PROPRIETARY TYPE X GYPSUM PANELS INSERTED BETWEEN 2 1/2" FLOOR AND CEILING RUNNERS WITH T SECTION OF 2 1/2" STEEL C-T STUDS BETWEEN PANELSONE LAYER 5/8' PROPRIETARY TYPE X GYPSUM WALLBOARD APPLIED PARALLEL TO STUDS WITH 1" TYPE S DRYWALL SCREWS 12" O.C.
3 1/8"1HR
5 1/4"I: DATA CABINET WALL NA
5/8" GWB1/2" PLYWD SHEATHINGFULL DEPTH MINERAL WOOL ACOUSTIC INSULATIONDATA
SECURE
5/8" GWB3 1/2" WD STUDS AT 16" OC
GENERAL: GENERAL ALL WALL TYPES, GWB BD TO EXTEND TO STRUCTURE
NOTE: WHERE (1) HR FIRE RATING IS REQUIRED STEEL FRAMING GA FILE: WP1072WOOD FRAMING GA FILE: WP3510
1. DO NOT SCALE DRAWINGS2. ALL WORK TO BE PERFORMED TO APPLICABLE BUILDING CODES.3. ALL DIMENSIONS ARE TO FACE OF FINISH UNLESS OTHERWISE NOTED. ALL DIMENSIONS INDICATING REQUIRED CLEARANCES ARE TO FACE OF FINISH UNLESS OTHERWISE NOTED.4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIM OR HERSELF WITH THE CONTRACT DOCUMENTS, VERIFYING FIELD CONDITIONS AND DIMENSIONS, AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. CONTRACTOR SHALL NOTIFY ARCHITECT IN WRITING OF ANY DISCREPANCY WITHIN THE CONTRACT DOCUMENTS AND REQUEST CLARIFICATION PRIOR TO PROCEEDING WITH CONSTRUCTION.5. SHOULD THERE BE ANY QUESTIONS CONCERNING THE CONTRACT DOCUMENTS, EXISTING CONDITIONS, AND/OR DESIGN INTENT, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE ARCHITECT PRIOR TO PROCEEDING WITH THE WORK, OR RELATED WORK IN QUESTION.6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH THE PROJECT SCOPE OF WORK, SCHEDULE, AND DEADLINES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADVISING THE ARCHITECT OF ALL ITEMS REQUIRING A LONG LEAD TIME UPON NOTICE TO PROCEED THAT WILL AFFECT THE SCHEDULE, AND SHALL SUBMIT ORDER CONFIRMATIONS AND DELIVERY DATES FOR THE ITEMS IN QUESTION TO THE OWNER.7. INSTALL ALL MANUFACTURED ITEMS, MATERIALS, AND EQUIPMENT IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDED SPECIFICATIONS, EXCEPT WHERE THE CONTRACT DOCUMENTS ARE MORE STRINGENT. ANY MISCELLANEOUS ITEMS OR MATERIALS NOT SPECIFICALLY NOTED, BUT REQUIRED FOR PROPER INSTALLATION SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR. THE CONTRACTOR SHALL FURNISH TO THE OWNER ALL WARRANTIES AND GUARANTEES REQUIRED AT THE CONCLUSION OF THE PROJECT.8. ALL CONTRACTOR OR SUPPLIER REQUESTS FOR SUBSTITUTIONS OF SPECIFIED ITEMS SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT WITHIN 14 DAYS OF NOTICE TO PROCEED, AND BE ACCOMPANIED WITH THE ALTERNATIVE PRODUCT INFORMATION. SUBSTITUTIONS WILL BE CONSIDERED ONLY IF IT DOES NOT SACRIFICE QUALITY, APPEARANCE, DELIVERY TIME, OR FUNCTION.9. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL HOOK UPS / UTILITY CONNECTIONS, ETC. TO TEMPORARY TRAILERS.
GENERAL NOTES
CEILING TYPES X
TYPE GRAPHIC REPRESENTATION FIRE RATING
GARDEN LEVEL CEILING ASSEMBLYGA FILE # 5310
ONE LAYER 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED AT RIGHT ANGLES TO RIGID FURRING CHANNELS 24" O.C. WITH 1" TYPE S DRYWALL SCREWS 12 O.C. GYPSUM BOARD END JOINTS LOCATED MIDWAY BETWEEN CONTINUOUS CHANNELS AND ATTACHED TO ADDITIONAL PIECES OF CHANNEL 60" LONG WITH SCREWS 12" O.C. RIGID FURRING CHANNELS APPLIED AT RIGHT ANGLES TO 4 X 10 OR DOUBLE 2 X 10 WOOD JOISTS 48" O.C. WITH TWO 1 1/4" TYPE S DRYWALL SCREWS AT EACH JOIST. WOOD JOISTS SUPPORTING 1 1/8" T &G PLYWOOD FLOOR.
1 5/8"1HR
Project NumberDateDrawn byChecked by
Anderson HallasArchitects, PCARCHITECTUREHISTORIC PRESERVATION
COPYRIGHT 2019ANY UNAUTHORIZED USE OF THESE DOCUMENTS IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF:ANDERSON HALLAS ARCHITECTS, P.C.
PLANNING
Issue
715 FOURTEENTH STREETGOLDEN, COLORADO 80401(303) 278-4378FAX (303) 278-0521
Scale AS NOTED
G0.3
GENERALINFORMATION /EGRESS PLAN
2017910
PITKIN COUNTY
COURTHOUSE REMODEL
PITKIN COUNTY, CO
5/2/19LWBRAS/NAA
506 E Main St St 300, Aspen, CO 81611
PERMIT
1/16" = 1'-0"1GARDEN LEVEL EGRESS PLAN6" = 1'-0"AIN LEVEL EGRESS PLAN
16" = 1'-0"ECOND LEVEL EGRESS PLAN
DRAWINGS BASED ON FLOOR PLANS PROVIDED BY PITKIN COUNTY. CONTRACTOR TO NOTIFY ARCHITECT OF ANY DEVIATIONS FROM ACTUAL FIELD CONDITIONS, PRIOR TO COMMENCING WITH WORK.
10.10.12 DIRECTION OF SWING PIVOT OR SIDE-HINGED SWINGING DOORS SHALL SWING IN THE DIRECTION OF EGRESS TRAVEL WHEN SERVING A ROOM OR AREA CONTAINING AN OCCUPANCY LOAD OF 50 OR MORE PERSONS.
119'-10"/3 = 39'-11"
45'-5"
119'-10"/3 = 39'-11"
52'-11"119'-10"/3 = 39'-11"
59'-10"
No. Description Date1 ADDENDUM 01 4/26/20193 ADDENDUM 03 6/12/2019
3
1
Provide the full installationinstructions from the GypsumManual for WP 1072, WP3510, WP 6800, FC3510 in theplan set for reference atinspection.
08/21/2019
NEW ACCESSIBLE ENTRANCE
MAX TRAVEL DISTANCE: 57'
1144 / 40SF / OCC
= 32 OCC
DELAYED EGRESS DOOR. PROVIDE WEATHER
PROOF SIGNAGE: PUSH UNTIL ALARM SOUNDS,
DOOR CAN BE OPENED IN 15 SECONDS
FEC
FEC
MAX TRAVEL DISTANCE: 115'
FEC
FEC
FEC
FEC
FEC
FEC
MAX TRAVEL DISTANCE: 125'
FEC
LEGEND
FEC
EGRESS PATH
EGRESS DOOR WITH
EXIT SIGNAGE
FIRE EXTINGUISHER
CABINET
EXIT SIGNAGE, RE: ELEC
TRAVEL DISTANCE
BUILDING DIAGONAL
DISTANCE
SIGNAGE: EMERGENCY
EXIT ONLY, ALARM WILL
SOUND UNLESS
ACTIVATED BY KEY
CARD
WALL TYPES X
A
TYPE
GRAPHIC
REPRESENTATION
FIRE
RATING
NA
WP1072: ONE LAYER 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER BASE
APPLIED PARALLEL OR AT RIGHT ANGLES TO EACH SIDE OF 3 5/8" STEEL STUDS 24"
O.C. WITH 1" TYPE S DRYWALL SCREWS 8" O.C. AT VERTICAL JOINTS AND 12" O.C. AT
FLOOR AND CEILING RUNNERS AND INTERMEDIATE STUDS. JOINTS STAGGERED 24"
ON EACH SIDE AND ON OPPOSITE SIDES. SOUND TESTED WITH 3 1/2" GLASS FIBER
FRICTION FIT IN STUD SPACE.
WP3510: ONE LAYER 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER BASE
APPLIED PARALLEL OR AT RIGHT ANGLES TO EACH SIDE OF 2X4 WOOD STUDS 24" O.C.
WITH 6D COATED NAILS, 1 7/8" LONG, 0.0915" SHANK, 1/4" HEADS, 7" O.C. JOINTS
STAGGERED 24" ON OPPOSITE SIDES.
5 1/2" WD STUDS AT 16" OC
FULL DEPTH MINERAL WOOL ACOUSTIC INSULATION
6
3
/
4
"
B NA
5/8" GWB
5 1/2" WD STUDS AT 16" OC
FULL DEPTH MINERAL WOOL ACOUSTIC INSULATION
3/8" PORCELAIN TILE, 5/8" CTBB / 5/8" MOISTURE RESISTANT GWB ABOVE
6
3
/
4
"
C: SECURE WALLS NA
1/2" PLYWOOD
5 1/2" WD STUDS AT 16" OC
FULL DEPTH MINERAL WOOL ACOUSTIC INSULATION
1/2" PLYWOOD SHEATHING
RR SIDE
5/8" IMPACT RESISTANT GWB
5/8" IMPACT RESISTANT GWB
D: PLUMB. CHASE
WALLS
5 1/2" WD STUDS AT 16" OC
FULL DEPTH MINERAL WOOL ACOUSTIC INSULATION
3/8" PORCELAIN TILE, 5/8" CTBB / 5/8" MOISTURE RESISTANT GWB
7
3
/
4
"
6
1
/
8
"
RR SIDE
2
1
/
8
"
E:
NA
NA
5/8" GWB
1 1/2" WD FURRING AT 16" OC
FULL DEPTH MINERAL WOOL ACOUSTIC INSULATION
PUBLIC
SECURE
F: ACOUSTIC
ISOLATION
NA
5/8" GWB
5 1/2" STAGGERED WD STUDS
AT 8" OC
FULL DEPTH MINERAL WOOL ACOUSTIC INSULATION RUNNING CONTINUOUSLY
IN BETWEEN STUDS
5/8" GWB
7
3
/
4
"
1" SPACE IN BETWEEN STUDS AND GWB, BOTH SIDES
G: MASONRY
INFILL
NAMASONRY INFILL, RE: STRUCT.
WD STUD S AT 16"O.C., ADJUST FURRING TO PROVIDE FLUSH FINISH
5/8" IMPACT RESISTANT GWB
5/8" IMPACT RESISTANT GWB
VA
R
I
E
S
WD STUD S AT 16"O.C., ADJUST FURRING TO PROVIDE FLUSH FINISH
H: SHAFT WALL
GA FILE #:WP 6800
ONE LAYER: 1" X 24" PROPRIETARY TYPE X GYPSUM PANELS
INSERTED BETWEEN 2 1/2" FLOOR AND CEILING RUNNERS WITH T
SECTION OF 2 1/2" STEEL C-T STUDS BETWEEN PANELS
OPPOSITE SIDE: ONE LAYER 5/8" PROPRIETARY TYPE X GYPSUM
WALLBOARD APPLIED PARALLEL TO STUDS WITH 1" TYPE S DRYWALL
SCREWS 12" O.C.
3
1
/
8
"
1HR
5
1
/
4
"
I: DATA CABINET
WALL
NA
5/8" GWB
1/2" PLYWD SHEATHING
FULL DEPTH MINERAL WOOL ACOUSTIC INSULATION
DATA
SECURE
5/8" GWB
3 1/2" WD STUDS AT 16" OC
GENERAL: GENERAL ALL WALL TYPES, GWB
BD TO EXTEND TO STRUCTURE
NOTE: WHERE (1) HR FIRE
RATING IS REQUIRED
STEEL FRAMING
GA FILE: WP1072
WOOD FRAMING
GA FILE: WP3510
4
4
1. DO NOT SCALE DRAWINGS
2. ALL WORK TO BE PERFORMED TO APPLICABLE BUILDING CODES.
3. ALL DIMENSIONS ARE TO FACE OF FINISH UNLESS OTHERWISE NOTED. ALL DIMENSIONS
INDICATING REQUIRED CLEARANCES ARE TO FACE OF FINISH UNLESS OTHERWISE NOTED.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIM OR HERSELF WITH THE
CONTRACT DOCUMENTS, VERIFYING FIELD CONDITIONS AND DIMENSIONS, AND CONFIRMING
THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH
CONSTRUCTION. CONTRACTOR SHALL NOTIFY ARCHITECT IN WRITING OF ANY DISCREPANCY
WITHIN THE CONTRACT DOCUMENTS AND REQUEST CLARIFICATION PRIOR TO PROCEEDING WITH
CONSTRUCTION.
5. SHOULD THERE BE ANY QUESTIONS CONCERNING THE CONTRACT DOCUMENTS, EXISTING
CONDITIONS, AND/OR DESIGN INTENT, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
OBTAINING A CLARIFICATION FROM THE ARCHITECT PRIOR TO PROCEEDING WITH THE WORK, OR
RELATED WORK IN QUESTION.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH THE PROJECT
SCOPE OF WORK, SCHEDULE, AND DEADLINES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
ADVISING THE ARCHITECT OF ALL ITEMS REQUIRING A LONG LEAD TIME UPON NOTICE TO
PROCEED THAT WILL AFFECT THE SCHEDULE, AND SHALL SUBMIT ORDER CONFIRMATIONS AND
DELIVERY DATES FOR THE ITEMS IN QUESTION TO THE OWNER.
7. INSTALL ALL MANUFACTURED ITEMS, MATERIALS, AND EQUIPMENT IN STRICT ACCORDANCE WITH
THE MANUFACTURER'S RECOMMENDED SPECIFICATIONS, EXCEPT WHERE THE CONTRACT
DOCUMENTS ARE MORE STRINGENT. ANY MISCELLANEOUS ITEMS OR MATERIALS NOT
SPECIFICALLY NOTED, BUT REQUIRED FOR PROPER INSTALLATION SHALL BE FURNISHED AND
INSTALLED BY THE CONTRACTOR. THE CONTRACTOR SHALL FURNISH TO THE OWNER ALL
WARRANTIES AND GUARANTEES REQUIRED AT THE CONCLUSION OF THE PROJECT.
8. ALL CONTRACTOR OR SUPPLIER REQUESTS FOR SUBSTITUTIONS OF SPECIFIED ITEMS SHALL BE
SUBMITTED IN WRITING TO THE ARCHITECT WITHIN 14 DAYS OF NOTICE TO PROCEED, AND BE
ACCOMPANIED WITH THE ALTERNATIVE PRODUCT INFORMATION. SUBSTITUTIONS WILL BE
CONSIDERED ONLY IF IT DOES NOT SACRIFICE QUALITY, APPEARANCE, DELIVERY TIME, OR
FUNCTION.
9. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL HOOK UPS / UTILITY CONNECTIONS, ETC. TO
TEMPORARY TRAILERS.
GENERAL NOTES
CEILING TYPES X
TYPE
GRAPHIC
REPRESENTATION
FIRE
RATING
GARDEN LEVEL
CEILING
ASSEMBLY
GA FILE # 5310
ONE LAYER 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER BASE
APPLIED AT RIGHT ANGLES TO RIGID FURRING CHANNELS 24" O.C. WITH 1" TYPE
S DRYWALL SCREWS 12 O.C. GYPSUM BOARD END JOINTS LOCATED MIDWAY
BETWEEN CONTINUOUS CHANNELS AND ATTACHED TO ADDITIONAL PIECES OF
CHANNEL 60" LONG WITH SCREWS 12" O.C. RIGID FURRING CHANNELS APPLIED
AT RIGHT ANGLES TO 4 X 10 OR DOUBLE 2 X 10 WOOD JOISTS 48" O.C. WITH TWO
1 1/4" TYPE S DRYWALL SCREWS AT EACH JOIST. WOOD JOISTS SUPPORTING 1
1/8" T &G PLYWOOD FLOOR.
1
5
/
8
"
1HR
Project Number
Date
Drawn by
Checked by
Anderson Hallas
Architects, PC
ARCHITECTURE
HISTORIC PRESERVATION
COPYRIGHT 2019
ANY UNAUTHORIZED USE OF THESE DOCUMENTS
IS PROHIBITED WITHOUT THE WRITTEN CONSENT
OF:
ANDERSON HALLAS ARCHITECTS, P.C.
PLANNING
Issue
715 FOURTEENTH STREET
GOLDEN, COLORADO 80401
(303) 278-4378
FAX (303) 278-0521
Scale AS NOTED
8/
1
4
/
2
0
1
9
6
:
1
6
:
0
0
P
M
G0.3
GENERAL
INFORMATION /
EGRESS PLAN
2017910
PITKIN COUNTY
COURTHOUSE REMODEL
PITKIN COUNTY, CO
5/2/19
LWB
RAS/NAA
506 E Main St St 300, Aspen, CO 81611
PERMIT
1/16" = 1'-0"1 GARDEN LEVEL EGRESS PLAN
1/16" = 1'-0"2 MAIN LEVEL EGRESS PLAN
1/16" = 1'-0"3 SECOND LEVEL EGRESS PLAN
DRAWINGS BASED ON FLOOR PLANS
PROVIDED BY PITKIN COUNTY. CONTRACTOR
TO NOTIFY ARCHITECT OF ANY DEVIATIONS
FROM ACTUAL FIELD CONDITIONS, PRIOR TO
COMMENCING WITH WORK.
10.10.12 DIRECTION OF SWING PIVOT OR SIDE-HINGED SWINGING
DOORS SHALL SWING IN THE DIRECTION OF EGRESS TRAVEL
WHEN SERVING A ROOM OR AREA CONTAINING AN OCCUPANCY
LOAD OF 50 OR MORE PERSONS.
119'-10"/3 = 39'-11"
45'-5"
119'-10"/3 = 39'-11"
52'-11"
119'-10"/3 = 39'-11"
59'-10"
No. Description Date
1 ADDENDUM 01 4/26/2019
3 ADDENDUM 03 6/12/2019
4 BUILDING
COMMENTS
8/14/2019
3
1
4
08/21/2019
Project Number
Date
Drawn by
Checked by
Anderson Hallas
Architects, PC
ARCHITECTURE
HISTORIC PRESERVATION
COPYRIGHT 2019
ANY UNAUTHORIZED USE OF THESE DOCUMENTS
IS PROHIBITED WITHOUT THE WRITTEN CONSENT
OF:
ANDERSON HALLAS ARCHITECTS, P.C.
PLANNING
Issue
715 FOURTEENTH STREET
GOLDEN, COLORADO 80401
(303) 278-4378
FAX (303) 278-0521
Scale AS NOTED
8/
1
4
/
2
0
1
9
6
:
1
6
:
0
3
P
M
G0.4
CODE SUMMARY
2017910
PITKIN COUNTY
COURTHOUSE REMODEL
PITKIN COUNTY, CO
5/2/19
LWB
RAS/NAA
506 E Main St St 300, Aspen, CO 81611
PERMIT
BUILDING CODE ANALYSIS • 705.1 General. A facility that is altered shall comply with the applicable provisions in section 705.1 through
705.1.14 and Chapter 11 of the International Building Code unless it is technically infeasible, the alteration
shall provide access to the maximum extent that is technically feasible. A facility that is constructed or
altered to be accessible shall be maintained accessible during occupancy.
2015 International Building Code
OCCUPANCY
A-3
B
CONSTRUCTION
Type III B
Type IIB Construction: Construction is that type of construction in which they exterior walls are of non-
combustible;e material and interior building elements are of any material permitted by code.
FLOOR AREA
ACTUAL FLOOR AREA
Floor A-3 B Total
Garden Level 1,473 3,827 5,300
First Floor 4,931 4,931
Second Floor 4,780 1,157 5,937
Total Area (sf)6,253 9,915 16,168
ALLOWABLE FLOOR AREA
Allowable Area Limitations, Table 506.2:
Allowable Area for Type III B, Occupancy A-3 = 8,000 sf/story
Allowable Area for Type III B, Occupancy B = 76,000,000 sf/story
FLOOR AREA COMPLIANCE
BUILDING HEIGHT
ACTUAL BUILDING HEIGHT
ALLOWABLE BUILDING HEIGHT
Maximum Height and Stories Limitations, Table 504.3:
For III B, A-3, maximum allowable building height = 75 feet
For III B, B, maximum allowable building height = 75 feet; maximum
Actual Building Height *45 feet -7 inches
* +/-70 feet with tower
Building Complies with Code
OCCUPANCY AREA and LOAD
Table 1004.1.2
Garden Level Area Occupancy Type Area Load Factor Occ Load
Office 3,837 Business 100 39
Court Room 1,244 Courtroom 40 32
Main Level
Office 4,931 Business 100 31
Second Level
Office 1,158 Business 100 12
District Court 2,444 Courtroom 40 62
County Court 1,087 Courtroom 40 28
Total 204
Section 1007.1.1 Two Exits or Exit Access Doorways:
Where two exits or exit access doorways are required from any portion of the exit access, the exit doors or
exit access doorways shall be placed a distance apart to not less than one-half of the length of the
maximum overall diagonal dimension of the building or area to be served measured in a straight line
between exit doors or exit access doorways.
Exception 2. Where buildings are equipped throughout with an automatic sprinkler system in accordance
with section 903.3.1.1 or 903.3.1.2. The separation distance shall be not less than one-third of the length of
the maximum overall dimension of the area served.
Area Allowable Diagonal Min Distance Actual Exit Distance
Garden Level 119'-10"39'-11"59'-10"
First Level 119'-10"39'-11"52'-11"
Second Level 119'-10"39'-11"45'-5"
Restrooms
2902.1 Minimum number of required plumbing facilities
Occupancy A3
B
men = 136
women = 136
Fixtures Ratio Number Req'd Provide
Water Closet male 1/25 for the first 50
1/50 exceeding 50 4 3 WC
1 urinal
female 1/25 for the first 50
1/50 exceeding 50 4 5 WC
Lavatories male 1/40 for the first 80
1/80 exceeding 80 4 3
female 1/40 for the first 80
1/80 exceeding 80 4 3
Drinking
Fountain 1/100 1 2
Service Sink 1 1
Unisex 5 WC
5 Lavs
Building Complies with Code if unisex fixtures can be counted towards the total required fixtures.
2015 International Energy Conservation Code
Table C301.1
Pitkin zone 7
C402.1 Building Envelope Fenestration
U Factor zone 7
Entrance Doors 0.77
SHGC SEW
0.45
Date:2019.03.15
Analysis By: Andy Duckett-Emke
Project Number:2017910
Project Name: Pitkin County Courthouse
Code analysis is based:
2015 International Building Code
2015 International Existing Building Code
2015 International Mechanical Code
2015 International Plumbing Code
2015 International Energy Conservation Code
2017 International Electrical Code
2015 International Existing Building Code
Section 505
505.1 Scope. Level 3 alterations apply where the work area exceeds 50 percent of the building area.
505.2 Application, Level 3 alterations shall comply with the provisions of Chapters 7 and 8 for level 1 and level 2 alterations, respectively,
as well as the provisions of Chapter 9.
• 803.2.1 Existing Vertical Opening: All existing interior openings shall comply with the provision of this section 803.2.1, 803.2.2
and 803.2.3
1. 803.2.1 Existing Vertical Openings. All existing interior vertical openings connection two or more floors shall be enclosed
with approved assemblies having a fire resistance rating of not less than (1) hour with an approved opening protective.
exception 3: The enclosure shall not be required where :
3.1 connects the main floor and mezzanine.
Provide (1) hour door at door 100 from Garden Level / Main Level door on magnetic hold opens.
• 804.1 scope: The requirements of this section shall be limited to work areas in which Level 2 Alterations are being performed
and where specified they shall apply throughout the story. The required fire-resistance rating for any corridor located on the
story shall be permitted to be reduced in accordance with the International Building Code. In order to be considered for a
corridor rating reduction, such system shall provide coverage for the stairway landing serving the floor and intermediate landings
immediately below.
• 805.3 Number of Exits: The number of exits shall be in accordance with Section 805.31 through 805.3.3
• 805.3.1 Minimum Number. Every story utilized for human occupancy on which there is a work area that includes exits or
corridors shared by more than one tenant within the work area shall be provided with the minimum number of exits based on the
occupancy and the occupant load in accordance withe the International Building Code. In addition the exits shall comply with
the Section 805.3.1.1 (2) exits shall be provided at each level.
• 805.3.1.2 Fire Escapes Required: For other than group I-2 where more than (1) exit is required, and existing or newly or
constructed fire escape comply with this section 805.3.1.2 shall be accepted as providing one of the required means of egress.
4. Openings within 10 feet of fire escape stairways shall be protected by fire assemblies having a minimum 3/4 hour fire
resistance rating.
exception: Opening protection shall not be required in buildings equipped throughout with an approved automatic fire sprinkler.
Existing openings are within 4'-6" of the proposed new egress. Building is equipped throughout with an automatic fire
suppression system.
• 805.4.4 Panic Hardware: In any work area and in the egress path for any work area to the exit discharge in buildings or portions
thereof of group A occupancy with an occupant load greater than 100. All required exit doors equipped with latching devices
shall be equipped with approved panic hardware.
Provide panic hardware at all existing doors in the patch of egress.
• 805.9 Requirement if section 805.9.1 and 805.9.2 shall apply to handrails from the work floor area to and including the level of
the exit of discharge.
• 805.9.1 Minimum Requirement. Every required exit stairway that is part of the means of egress for any work area that has three
or more risers and is not provided with at least one handrail , or in which the existing handrails are judged to e in danger of
collapse, shall be provided with handrails for the length of the stairway on at least one side. All egress stairways with a required
egress width of more than 66 inches shall have handrails on both sides.
Existing stair is 61 inches wide. Provide new code compliant handrail to wall
Stair to second level is 102 inches wide. Provide new code compliant handrail at center of stair.
• 805.11 Guards. The requirement of section 805.11.1 and 805.11.2 shall apply to guards from the work area floor and including
the level of exit of discharge shall be confined to egress path of an work area.
• 805.11.1 Minimum Requirements. Every open portion of a stairway landing, or balcony that is more than 30 inches above the
floor or grade below and is not provided with guards or those portions in which existing guards are judged in danger of collapse,
shall be provided with guards. Existing guard rails at second level are 32 inches tall and are not to code. Provide new code
complaint guard at second level.
• 901.2 Compliance. In addition to the provisions of this chapter, work shall comply with all of the requirements of Chapters 7 and
8. The requirements of Sections 803, 804 and 805 shall apply within all work areas whether or not they include exits and
corridors shared by more than one tenant and regardless of the occupant load.
• 902.1.2 Elevators. Where these is an elevator or elevators for public use, at least one elevator serving the work area shall
comply with this section. Existing elevators with a travel distance of 25 feet or more above or below the main floor or other level
of a building and intended to serve the needs of emergency personnel for fire fighting or rescue purposed shall be provided with
emergency operation in accordance with ASME A17.3. New elevators shall be provided with Phase I emergency recall
operations and Phase II emergency in-car operation in accordance with ASME A17.1.
• 903.1 Existing shafts and vertical openings. Existing stairway that are part of the means of egress shall be enclosed in
accordance with Section 803.2.1 from the highest work area floor to and including, the level of exit discharge and all floors
below.
The Main and Second Level are connected by an existing open stair. The Garden and Main level are not separated by one-
hour construction. Provide a one hour enclosure between the Garden Level and Main Level.
• 904.1 Automatic sprinkler system. An automatic sprinkler system shall be provided in a work area where required by Section
804.2 of this section.
• 804.2 Groups A,B,E,F1.H1,M,I,S1 and S2. In buildings with indicated occupancies, work areas that have exits or corridors
shared by more than one tenant or that have exits or corridors serving an occupant load greater than 30 shall be provided with
automatic sprinkler protection where all of the following conditions occur:
1. The work areas is required to be provided with automatic sprinkler protection in accordance with the International Building
Code as applicable to new construction and.
2. The work areas exceed 50 percent of the floor area. The work area is required to be provided with an automatic sprinkler
system in accordance with the International Building Code applicable to new constriction; and (E) Automatic sprinkler
system to be modified via design build to accommodate (N) layout.
• 904.2 Fire alarm and detection system. Fire alarm and detection shall be provided in accordance with Section 907 of the
International Building Code as required for new construction.
• (E) Fire alarm and detection system to be modified
• 905.1 General. The means of egress shall comply with the requirements of Section 805 except as specifically required in
Sections 905.2 and 905.3. see sections above
• 905.2 Means of egress lighting. Means of egress from the highest work area floor to the floor of exit of discharge shall be
provided with artificial lighting within the exit enclosure in accordance with the requirements of the International Building Code.
• Emergency egress lighting to be provided, Re: Electrical
• 905.3 Exit signs. Means of egress from the highest work area floor to the floor of exit discharge shall be provided with exit signs
in accordance with the requirements of the International Building code.
• 906.1 General. A building, facility or elements that is altered shall comply with this section and sections 705 and 806.
BUILDING HEIGHT COMPLIANCE
Building complies with building code
BUILDING NUMBER OF STORIES
ACTUAL BUILDING NUMBER OF STORIES = 3
ALLOWABLE BUILDING NUMBER OF STORIES
Maximum Stories Limitations, Table 504.4:
For III B, A-3, allowable stories = 3
For III B, B, maximum allowable stories = 4
BUILDING HEIGHT AND NUMBER OF STORIES COMPLIANCE
Actual number of stories = 3
Building Complies with Code
OTHER BUILDING ELEMENTS FIRE RATINGS
Fire-Resistance Rating Requirements for Building Elements, Table 601:
ELEMENT III B RATING
Structural frame 0 hour
Bearing walls
Exterior 2 hour
Interior 0 hour
Non-bearing walls & partitions
Exterior 0 hour
Interior 0 hour
Floor construction 0 hour
Roof construction 0 hour
OTHER BUILDING ELEMENTS FIRE RATINGS COMPLIANCE
Building complies with code requirements.
OCCUPANCY SEPARATIONS
No separation required between occupancies based on:
Non-separated Occupancies, Sec. 508.3.: Building or portions of buildings that comply with the
provisions of this section shall be considered non-separated occupancies.
508.3.2 Allowable building area and height. The allowable building area and height of the building or
portion thereof shall be based on the most restrictive allowances for the occupancy groups under
consideration (for this building Occupancy A2 is assumed to be the most restrictive) for the type of
construction of the building in accordance with Section 503.1.
Building complies with code requirements.
No. Description Date
4 BUILDING
COMMENTS
8/14/2019
4
08/21/2019
176 SF
BOILER
01A
72 SF
MECH/ELEC
02D
35 SF
JAN.
00A
98 SF
STORAGE
00B
332 SF
HOLDING
06
143 SF
CONF. RM
08
87 SF
JUDGE RR
14
709 SF
COURTROOM 3
05
53 SF
HALL
16
372 SF
JURY DELIBERATION
03
13B
01
05A
17
ACCESSIBLE NEW
WALK. RE: CIVIL
06
NF6
NF6
NF6NF6NF6
NF3
NF8UP
U
P
UP
UP
UP
5'
-
0
"
UP
NEW ACCESSIBLE CONC RAMP. MAX SLOPE 1:12. RE: CIVIL
102 SF
WOMEN
00C
113 SF
MEN
00D
INFILL <E> OPENING,
RE:STRUCT.
M.O.
4' - 1"5'
-
0
"
6' - 2 1/2"
5"
A9.9
1
A9.8
2
A4.0
2
47 SF
STORAGE
15
70 SF
SECURE HALL
13
49 SF
ELEV. MECH.
00E
A7.3
1
55 SF
VEST.
03A
122 SF
ATTORNEY
01
615 SF
HALL
00
110 SF
HALL
09
59 SF
HALL
10
408 SF
VISITING JUDGE'S
CHAMBERS
04
49 SF
HALL
05A
<N> RAISED
PLATFORM FOR
JUDGE'S BENCH
06A
06B
85 SF
ATTORNEY
06A
20 SF
MECH.
06B
4'
-
6
"
NF6
NF9NF9 NF9 NF9
03
49 SF
JURY RR
07
07
89 SF
ALPINE LEGAL
02E
116 SF
OFFICE 1
02C
103 SF
OFFICE 2
02B
197 SF
BREAK ROOM
02A
85 SF
VEST.
02
02C02B
02A
02E
DW
55 SF
ELEV.
11
UP
UP
UP
A
A
B
B
A
A
A
A
A
A
C
F
A
C
<N> CABINET
A7.5
1
A9.12
1
F
C
ALIGN
9'
-
2
"
R.O.
3' - 2"
5 1/2"
13A
08
A4.0
1
13' - 4 1/2"
2' - 10"
8' - 2"
10
'
-
6
"
8' - 1 1/2"
R.O.
3' - 2"4' - 5 1/2"
3' - 11 1/2"
6'
-
1
1
"
12' - 5"
6'
-
1
1
1
/
2
"
5' - 8"
9
1
/
2
"
5"
R.O.
3' - 2"
5"
13' - 3"
7"
D
ALIGN
100' - 0"
100' - 0"
A7.1
1
76 SF
LOWER LIFT LOBBY
17
A9.2
1
A
I
NF10
NF10
04
12
00
09
M.O.
3' - 4"
3' - 5"
R.O.
3' - 2"
1' - 5"
R.O.
3' - 2"
1' - 5"
1' - 6"
10' - 0"
R.O.
3' - 2"
8 1/2"
R.O.
3' - 2"
R.O.
3' - 2"
HOLD
1' - 0"
R.O.
3' - 2"
R.O.'
3' - 2"
R.O.
3' - 2"1' - 4"
R.O.
3' - 2"
R.O.
3' - 2"
1' - 0"1' - 0"
ALIGN F.O. <N> WALL
WITH CENTER LINE OF
<E> COLUMN.
NF15
1' - 6"
FIN.
4' - 6"
00B
00A
00E
05
04A00D
00C
02D
01A
HOLD
3' - 6"
16
F
18
REF.
D
D
NF20
NF20
06B
05A
05B 05C
05D
05E
06C
06A06D
06E
NF6
NF6NF6
NF6
3' - 6"
8 1/4"
7"
A9.2
6
INSTALL <N> SCREEN
OVER CONDUIT
INSTALL <N> SCREEN
OVER CONDUIT
PROVIDE <N> VERTICAL GRAB
BAR AT ACCESSIBLE STALL &
UNDERCOUNTER PIPE
PROTECTION
M.O.
3' - 4"
A0.25
NF26
NF27
NF28
NF29
05B 05C
15
14
B
NF9
NF9NF9
NF9
NF9
NF9 NF9NF9
C
NF9
NF9
A
A
A
A
G
G
NF15
DN
INSTALL <N> 2" THICK
CONC "BENCH" OVER
FOUNDATION
INSTALL <N> 4X4 STL
ANGLE TO SUPPORT
CONC BENCH END
EGRESS STAIR
FOUNDATION, RE: STRUC
NF37
CONTRACTOR SHALL CONNECT
NEW INTERNAL ROOF DRAIN TO
NEW STORM SEWER: REF CIVIL
REF STRUCTURAL FOR MATERIAL AND
SIZING FOR STRUCTURAL ELEMENTS IN
WALL TYPA AT NEW LIFT STRUCTURE
SIM
SIM
D
E
1
1
PROVIDE MINIMAL WALL PENETRATION
INVERT OF 7903.83' TO ACHIEVE A MINIMUM
1% SLOPE TO STORM SEWER TIE-IN
1
2' - 5"
4
NF30 NF30
4
4
5
4
NF30
NF30
4
4
LEGEND
<E> WALL
NEW WALL
NEW DOOR
NEW FLOOR STRUCTURE, RE:
STRUC
REPAIR CONCRETE SLAB.
PROVIDE CONSISTENT FLOOR
LEVEL PRIOR TO INSTALLING
NEW FLOOR FINISH.
FLOOR ELEVATION
KEYNOTE
DOOR TAG
WALL TYPE
#
-
101
X
GENERAL NOTES
1. PATCH AND REPAIR ALL FINISHES AFFECTED BY CONSTRUCTION.
MATCH ADJACENT FINISH.
2. COORDINATE REUSE, SALVAGE, OR DISPOSAL OF ALL DEMO ITEMS
WITH OWNER.
3. REMOVE & SALVAGE <E> WINDOW TREATMENTS. COORDINATE
REINSTALLATION WITH PITKIN COUNTY/ 9TH JUDICIAL DISTRICT.
4. FURNITURE BY OTHERS. SHOWN FOR REFERENCE.
5. PITKIN COUNTY TO BE RESPONSIBLE FOR REMOVING /
RELOCATING ALL <E> FURNITURE.
6. REFERT TO M, P, E, & S SHEETS FOR ADDITIONAL INFORMATION.
7. REFER TO FINISH PLANS AND RCPS FOR ADDITIONAL
INFORMATION.
8. ALL REPOSITIONED COURTROOM FURNITURE TO PROVIDE 30"
CLEAR.
9. REMOVE AND SALVAGE <E> SIGNAGE (FLAGS AND WALL
MOUNTED). MODIFY FOR <N> ROOM NAMES. INSTALL <N> TO
MATCH <E> WHERE NEEDED.
10. REFER TO A 9.7 FOR ADDITIONAL CLERESTORY.
N
Project Number
Date
Drawn by
Checked by
Anderson Hallas
Architects, PC
ARCHITECTURE
HISTORIC PRESERVATION
COPYRIGHT 2019
ANY UNAUTHORIZED USE OF THESE DOCUMENTS
IS PROHIBITED WITHOUT THE WRITTEN CONSENT
OF:
ANDERSON HALLAS ARCHITECTS, P.C.
PLANNING
Issue
715 FOURTEENTH STREET
GOLDEN, COLORADO 80401
(303) 278-4378
FAX (303) 278-0521
Scale AS NOTED
8/14/2019 6:15:28 PM
A1.0
GARDEN LEVEL
FLOOR PLAN
2017910
PITKIN COUNTY
COURTHOUSE REMODEL
PITKIN COUNTY, CO
5/2/19
LWB
RAS/NAA
506 E Main St St 300, Aspen, CO 81611
PERMIT
3/16" = 1'-0"1 GARDEN LEVEL FLOOR PLAN
KEYNOTES
Key Value Keynote Text
NF3 PROVIDE <N> ACCESSIBLE WHEELCHAIR
LIFT.
NF6 ADD ALT #1: PROVIDE <N> INTERIOR
STORM WINDOW WITH BULLET
RESISTANT GLAZING.
NF8 PROVIDE <N> POST-MOUNTED AUTO
OPENER. POWDER COAT POST TO
MATCH HANDRAILS.
NF9 PROVIDE FROSTED PRIVACY FILM ON
<E> WINDOWS.
NF10 PROVIDE <N> WALL MOUNTED WD 1 1/2"
DIAMETER WD HANDRAILS.
NF15 INFILL WALL WITH MASONRY, RE: STRUC.
PROVIDE SMOOTH AND FLUSH FINISH TO
MATCH <E> ADJACENT FURRING AND
FINISH.
NF20 INSTALL <N> HIGH IMPACT RESISTANT
GYP. BD. WALL FINISH ON <E> FURRING,
INSTALL <N> FURRING (TO MATCH <E>)
AS NEEDED FOR <N> OPENING AT
EXISTING ELEVATOR CORE.
NF26 THE CAB HAS THREE SETS OF
CONTROLS. (2) AT STANDARD HEIGHT ON
REAR AND FRONT OF CAB AND A THIRD
SET OF CONTROLS MOUNTED AT 29" AFF.
REMOVE THIRD SET OF CONTROLS.
UPDATETHE CONTROL OPTIONS TO
INCORPORATE <N> CALL BUTTON TO <N>
SIDE OF GARDEN LEVEL, AND
SECURE/DESIGNATED ACCESS FOR
IN-CUSTODIES AND STAFF.
NF27 REMOVE <E> VINYL TILE FLOOR.
PROVIDE <N> CARPET TILE FLOOR
FINISH. PROVIDE <N> INTERIOR CAB
FINISH ON ALL 4 WALLS. PROVIDE <N>
CEILING FINISH AND LIGHTING. REMOVE
<E> AUXILIARY PANEL.
NF28 PROVIDE CAB CONTROLS VIA CARD
ACCESS TO ALLOW FOR LOCKOUT FOR
EITHER JUDGE OR IN-CUSTODY
TRANSPORT.
NF29 PROVIDE VERTICAL ACCESSIBLE GRAB
BAR IN <E> RESTOOM. RE: A 9.3
NF30 PROVIDE <N> VERTICAL, ACCESSIBLE
GRAB BARS. RE: 1/A9.8 FOR MOUNTING
LOCATION. PROVIDE PIPE PROTECTION
AT SINK.
NF37 PROVIDE <N> PLUMBING CHASE FOR <N>
ROOF DRAIN WITH 6" MIN INTERIOR
CLEAR. SIZE OF PIPE TO BE CONFIRMED
VIA DESIGN BUILD.
DRAWINGS BASED ON FLOOR PLANS
PROVIDED BY PITKIN COUNTY. CONTRACTOR
TO NOTIFY ARCHITECT OF ANY DEVIATIONS
FROM ACTUAL FIELD CONDITIONS, PRIOR TO
COMMENCING WITH WORK.
DRAWINGS BASED ON FLOOR PLANS
PROVIDED BY PITKIN COUNTY. CONTRACTOR
TO NOTIFY ARCHITECT OF ANY DEVIATIONS
FROM ACTUAL FIELD CONDITIONS, PRIOR TO
COMMENCING WITH WORK.
0 4' 8'12'
1
No. Description Date
1 ADDENDUM 01 4/26/2019
4 BUILDING
COMMENTS
8/14/2019
5 ASI #1 8/14/2019
08/21/2019
IT
106
FILE/COPY
102D STORAGE
112
PROBATION
108
PROBATION RR
108D
OFFICE 1
108E
OFFICE 2
108C
OFFICE 3
108B
WAITING
108A
CLOSET
108F
HALL
105
OFFICE 2
105B
MEETING
ROOM
105C
CLERKS
102
WAITING/
SELF HELP
102A
CLERK
WORKSTATIONS
103
FAMILY COURT/
COLLECTIONS
102B OFFICE 1
104
108E
104
NF3
DN
DN
D
N
DN
DN
PROVIDE NEW MTL
EGRESS STAIR AND
SECURITY
ENCLOSURE.
DN
<N> CONC. RAMP, MAX. SLOPE 1:12. RE: CIVIL
A7.3
2
MEN
113
WOMEN
114
11' - 9"
10
'
-
1
1
"
ALIGN
10' - 0 1/2"
6'
-
7
"
R.O.
3' - 2"
7"
1' - 4"
UP UP
DN
DN
A9.9
2
HALL
100
UP
4' - 3 1/2"
102B
TRANSACTION
COUNTER : REF 5:A9.3
3 SELF-HELP
STATIONS
SECURITY
SCREENING
115
VEST.
100A
VEST.
110
HALL
103A
ELEV.
111
INFORMAL MTG
105A
B
A
F
A
A
A
A
<N> ACCESSIBLE RAILINGS<N> ACCESSIBLE
RAILINGS
ALIGN
101C
101B
OFFICE 1
101B
OFFICE 2
101C
WITNESS
WAITING
101D
DA OFFICE
101
OFFICE 4
101E
101E
A
A A101D
OFFICE 3
101F
101F
A
WAITING
101A
OPEN TO
BELOW
A9.6
2
A9.6
3
A9.4
4
A9.4
5
A9.34
A9.3 5
V.I.F.
15' - 7"
12' - 2 1/2"
10 1/2"
V.I.F.
4' - 10 1/2"
1"
HOLD
5' - 0"
1"
V.I.F.
0"
1' - 0"
V.I.F.
11' - 4"
9' - 6"
9' - 11 1/2"
6' - 8"
4 1/2"ALIGN
A
A
A9.4
1
108
ALIGN
2
A9.3
A7.1
1
A
ALIGN
R.O.
3' - 2"
4' - 0 1/2"
ALIGN
R.O.
3' - 2"
R.O.
3' - 2"
6 1/2"
R.O.
3' - 2"
R.O.
3' - 2"
R.O.
3' - 2"
R.O.
3' - 2"
V.I.F.
4' - 4"R.O.
3' - 2"1' - 0"
12' - 2 1/2"
HOLD
1' - 6"
ALIGN
7' - 1"
A
AL
I
G
N
110A 110
100A
100B
6"
6"
NF14
E
A9.6
1
152
C
102D
115
102102A
106 105B
105C
108C
108B
100C
101A 113
100
112
114
108F
108A
NF19
A4.0
4
X RAY
73" x 47"
MAGNETOMETERS
36" x 28"
DEMOUNTABLE
GLASS PARTITION
6' HT
1' - 6"
R.O.
3' - 2"
102C
A9.7
1
1' - 10"
4' - 4"
1' - 8"
4' - 4"1' - 6"
2' - 7"
2' - 2"
H
H
H
PROVIDE <N> VERTICAL GRAB
BAR AT ACCESSIBLE STALL &
UNDERCOUNTER PIPE
PROTECTION
WALL-MOUNTED
SWING SECURITY
EXIT GATE
A4.0
3
A4.0
6
108D
103A
6
NF25
NF23
1' - 4 1/2"
1' - 0 1/2"
E
SE
C
U
R
I
T
Y
ST
A
F
F
MIN
3' - 0"
MIN
3' - 6"
A4.0
7
A4.0
7
A4.0
7
A4.0
8
A9.3
1
3
A9.3
A9.7
5
MIN.
1' - 0"
4
7' - 0"
H
1' FLOOR
A
NF30
NF30
VAULT DOOR WORK:
1. PROTECT EXISTING ROOM SIDE VAULT DOORS
REMAIN.
2.PROVIDE NEW ACCESSIBLE HALF SADDLE THRESHOLD
AT VAULT DOOR OPENING. NEW THRESHOLD TO BE THE
ENTIRE DEPTH OF MASONRY WALL.
3.VERIFY 32 INCHES CLEAR OPENING
4.MAINTAIN 48 INCHES CLEAR MANUEVERING SPACE AT
BOTH SIDES OF OPENING.
VAULT DOOR WORK:
1. PROTECT EXISTING ROOM SIDE VAULT DOORS
REMAIN.
2.PROVIDE NEW ACCESSIBLE HALF SADDLE THRESHOLD
AT VAULT DOOR OPENING. NEW THRESHOLD TO BE THE
ENTIRE DEPTH OF MASONRY WALL.
3.VERIFY 32 INCHES CLEAR OPENING
4.MAINTAIN 48 INCHES CLEAR MANUEVERING SPACE AT
BOTH SIDES OF OPENING.
1' - 11"
2' - 10"
HOLD
3' - 10 1/2"
AL
I
G
N
V.I.F.
6' - 4"
V.I.F.
1"
A
E
AA
NF38
NF32
NF32
NF32
NF32 NF32
NF33
NF34
A
A
A
A
A9.7 76
3' - 5"
101
REF.
1
NF37
4
4
1' FLOOR
4
NF30
NF30
4
LEGEND
<E> WALL
NEW WALL
NEW DOOR
NEW FLOOR STRUCTURE, RE:
STRUC
REPAIR CONCRETE SLAB.
PROVIDE CONSISTENT FLOOR
LEVEL PRIOR TO INSTALLING
NEW FLOOR FINISH.
FLOOR ELEVATION
KEYNOTE
DOOR TAG
WALL TYPE
#
-
101
X
GENERAL NOTES
1. PATCH AND REPAIR ALL FINISHES AFFECTED BY CONSTRUCTION.
MATCH ADJACENT FINISH.
2. COORDINATE REUSE, SALVAGE, OR DISPOSAL OF ALL DEMO ITEMS
WITH OWNER.
3. REMOVE & SALVAGE <E> WINDOW TREATMENTS. COORDINATE
REINSTALLATION WITH PITKIN COUNTY/ 9TH JUDICIAL DISTRICT.
4. FURNITURE BY OTHERS. SHOWN FOR REFERENCE.
5. PITKIN COUNTY TO BE RESPONSIBLE FOR REMOVING /
RELOCATING ALL <E> FURNITURE.
6. REFERT TO M, P, E, & S SHEETS FOR ADDITIONAL INFORMATION.
7. REFER TO FINISH PLANS AND RCPS FOR ADDITIONAL
INFORMATION.
8. ALL REPOSITIONED COURTROOM FURNITURE TO PROVIDE 30"
CLEAR.
9. REMOVE AND SALVAGE <E> SIGNAGE (FLAGS AND WALL
MOUNTED). MODIFY FOR <N> ROOM NAMES. INSTALL <N> TO
MATCH <E> WHERE NEEDED.
10. REFER TO A 9.7 FOR ADDITIONAL CLERESTORY.
Project Number
Date
Drawn by
Checked by
Anderson Hallas
Architects, PC
ARCHITECTURE
HISTORIC PRESERVATION
COPYRIGHT 2019
ANY UNAUTHORIZED USE OF THESE DOCUMENTS
IS PROHIBITED WITHOUT THE WRITTEN CONSENT
OF:
ANDERSON HALLAS ARCHITECTS, P.C.
PLANNING
Issue
715 FOURTEENTH STREET
GOLDEN, COLORADO 80401
(303) 278-4378
FAX (303) 278-0521
Scale AS NOTED
8/14/2019 6:15:31 PM
A1.1
MAIN LEVEL FLOOR
PLAN
2017910
PITKIN COUNTY
COURTHOUSE REMODEL
PITKIN COUNTY, CO
5/2/19
LWB
RAS/NAA
506 E Main St St 300, Aspen, CO 81611
PERMIT
N
3/16" = 1'-0"1 MAIN LEVEL FLOOR PLAN
KEYNOTES
Key Value Keynote Text
NF3 PROVIDE <N> ACCESSIBLE
WHEELCHAIR LIFT.
NF14 PROVIDE <N> CHASE. MINIMUM 5"
INTERIOR CLEARANCE.
NF19 <E> DOOR TO BE FASTENED IN
THE CLOSED POSITION. <E>
TRANSOM ABOVE SHOULD HAVE
MIRRORED FILM APPLIED BEHIND
GLASS. REMOVE DOOR KNOB
INFILL HOLE WHERE WHERE
HARDWARE REMOVED. PROVIDE
FLUSH FINISH WITH
SURROUNDING WD, PAINT TO
MATCH.
NF23 FIX DOOR IN OPEN POSITION.
NF25 CUT THROUGH <E> STONE
FOUNDATION WALL. PROVIDE
<N> DOOR ACCESS TO THE
NORTH OF THE <E> ELEVATOR.
NF30 PROVIDE <N> VERTICAL,
ACCESSIBLE GRAB BARS. RE:
1/A9.8 FOR MOUNTING LOCATION.
PROVIDE PIPE PROTECTION AT
SINK.
NF32 <N> CLERESTORY WINDOW
ABOVE. RE: INT. ELEVATIONS
NF33 <E> COLUMN TO REMAIN.
NF34 REINSTALL SALVAGED
MILLWORK ON <N> WALL.
PROVIDE <N> WD ACCESS
PANEL.
NF37 PROVIDE <N> PLUMBING CHASE
FOR <N> ROOF DRAIN WITH 6"
MIN INTERIOR CLEAR. SIZE OF
PIPE TO BE CONFIRMED VIA
DESIGN BUILD.
NF38 ALIGN <N> WALLS WITH <E>
COLUMNS.
DRAWINGS BASED ON FLOOR PLANS
PROVIDED BY PITKIN COUNTY. CONTRACTOR
TO NOTIFY ARCHITECT OF ANY DEVIATIONS
FROM ACTUAL FIELD CONDITIONS, PRIOR TO
COMMENCING WITH WORK.
0 4' 8'12'
1
No. Description Date
1 ADDENDUM 01 4/26/2019
4 BUILDING
COMMENTS
8/14/2019
4
08/21/2019
Project Number
Date
Drawn by
Checked by
Anderson Hallas
Architects, PC
ARCHITECTURE
HISTORIC PRESERVATION
COPYRIGHT 2019
ANY UNAUTHORIZED USE OF THESE DOCUMENTS
IS PROHIBITED WITHOUT THE WRITTEN CONSENT
OF:
ANDERSON HALLAS ARCHITECTS, P.C.
PLANNING
Issue
715 FOURTEENTH STREET
GOLDEN, COLORADO 80401
(303) 278-4378
FAX (303) 278-0521
Scale AS NOTED
8/
1
4
/
2
0
1
9
6
:
1
5
:
3
5
P
M
A5.0
DOOR SCHEDULE
2017910
PITKIN COUNTY
COURTHOUSE REMODEL
PITKIN COUNTY, CO
5/2/19
LWB
RAS/NAA
506 E Main St St 300, Aspen, CO 81611
PERMIT
DOOR SCHEDULE
MARK <E>
FRAME
TYP
FRAME
MATERIAL
DOOR
TYPE
DOOR
MATERIAL
NEW
TRIM
SIZE
HARDWARE COMMENTSTHICK WIDTH HEIGHT
00 No <E> WD B WD No 1 3/4" 2' - 11" 7' - 11" 01 NEW EXTERIOR WOOD DOOR: VERIFY OPENING SIZE
00A Yes <E> WD <E> WD No 1 3/4" 2' - 4" 7' - 0" 02
00B Yes <E> STL <E> WD No 1 3/4" 2' - 8" 7' - 0" SF01 EXISTING SAFE DOOR: NO WORK
00C Yes <E> WD <E> WD No 1 3/4" 2' - 6" 7' - 0" 04
00D Yes <E> WD <E> WDW No 1 3/4" 3' - 0" 7' - 0" 04
00E Yes <E> WD <E> WD No 1 3/4" 3' - 0" 7' - 0" 03
01 No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 35
01A Yes <E> WD <E> WD No 1 3/4" 3' - 0" 7' - 0" 02
02A No B WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 36
02B No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 06
02C No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 06
02D Yes <E> WD <E> WD No 1 3/4" 2' - 8" 7' - 0" 02
02E No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 36
03 No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 35
04 No <E> WD B WD No 1 3/4" 2' - 11" 7' - 11" 09 NEW EXTERIOR WOOD DOOR: VERIFY OPENING SIZE
04A Yes <E> WD <E> WD No 1 3/4" 3' - 0" 7' - 0" 08
05 Yes <E> WD <E> WD No 1 3/4" 3' - 2" 7' - 0" 08
05A No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 10
05B No - WD E WD No 1 3/4" 3' - 0" 3' - 0" 05 HALF-HEIGHT SWINGING GATE
05C No - WD E WD No 1 3/4" 3' - 0" 3' - 0" 05 HALF-HEIGHT SWINGING GATE
06 No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 31
06A No B WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 12
06B No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 03
07 No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 13
08 No A WD A WD No 1 3/4" 3' - 0" 7' - 0" 36
09 No <E> WD B WD No 1 3/4" 3' - 0" 7' - 0" 01 NEW EXTERIOR WOOD DOOR: VERIFY OPENING SIZE
12 No <E> WD B WD No 1 3/4" 3' - 0" 7' - 0" 15 NEW EXTERIOR WOOD DOOR: VERIFY OPENING SIZE
13A No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 11
13B No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 11
14 No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 16
15 No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 02
16 No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 17 EXISTING DOOR: PROVIDE POWER ASSIST OPENER
17 No RE: A5.1 WD B WD Yes 1 3/8" 3' - 0" 7' - 0" 18 NEW EXTERIOR WOOD DOOR: VERIFY OPENING SIZE
18 No - STL F No 1 3/4" 3' - 6" 6' - 0" SG01 SECURITY GATE
19 No - STL - STL No 1 3/4" 3' - 6" 6' - 0" SG01 SECURITY GATE
100 Yes <E> WD <E> WD No 1 3/4" 2' - 10" 6' - 4" 19 EXISTING DOOR: PROVIDE NEW ELECTRIC DOOR HOLD OPENS
100A No <E> WD C WD No 2" 5' - 8" 8' - 11" 20 NEW EXTERIOR WOOD DOOR: VERIFY OPENING SIZE
100B No <E> WD C WD No 2" 5' - 8" 8' - 11" 21 NEW EXTERIOR WOOD DOOR: VERIFY OPENING SIZE
100C Yes <E> WD <E> WD No 1 3/4" 2' - 10 1/2" 7' - 0" EX01 FIX DOOR IN CLOSED POSITION, APPLY MIRRORED FILM TO TRANSOM, REMOVE DOOR KNOB - PROVIDE MTL
PLATE TO MATCH HARDWARE FINISH TO CONCEAL HOLES
101 Yes <E> WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 36
101A Yes <E> WD <E> WD No 1 3/4" 3' - 0" 7' - 0" 22
101B No C WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 06
101C No C WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 06
101D No C WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 23
101E No C WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 06
101F No C WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 06
102 Yes <E> WD <E> WD No 1 3/4" 3' - 0" 7' - 0" 22
102A Yes <E> WD <E> WD No 1 3/4" 3' - 0" 7' - 0" 22
102B No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 24
102C No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 24
102D Yes <E> WD <E> WD No 1 3/4" 2' - 8" 7' - 0" SF01 EXISTING SAFE DOOR: REFER TO PLANS FOR WORK
103A Yes <E> WD <E> WD No 1 3/4" 3' - 0" 7' - 0" 02
104 No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 06
105B Yes <E> WD <E> WD No 1 3/4" 3' - 0" 7' - 0" 06
105C Yes <E> WD <E> WD No 1 3/4" 2' - 10" 7' - 0" 36 <E> DOOR
106 Yes <E> WD <E> WD No 1 3/4" 3' - 0" 7' - 0" 22
108 No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 26
108A Yes <E> WD <E> WD No 1 3/4" 2' - 10" 7' - 0" 26 <E> DOOR
108B Yes <E> WD <E> WD No 1 3/4" 2' - 8" 7' - 0" 06 <E> DOOR
108C Yes <E> WD <E> WD No 1 3/4" 2' - 8" 7' - 0" 06 <E> DOOR
108D No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 27
108E No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 06
108F Yes <E> WD <E> WD No 1 3/4" 2' - 6" 7' - 0" 03
110 No <E> WD C WD No 2" 5' - 8" 8' - 11" 21 NEW EXTERIOR WOOD DOOR: VERIFY OPENING SIZE
110A No <E> WD C WD No 2" 5' - 8" 8' - 11" 20 NEW EXTERIOR WOOD DOOR: VERIFY OPENING SIZE
112 Yes <E> WD <E> WD No 1 3/4" 3' - 0" 7' - 0" SF01 EXISTING SAFE DOOR: REFER TO PLANS FOR WORK
113 Yes <E> WD <E> WD No 1 3/4" 2' - 10" 7' - 0" 13 <E> DOOR
114 Yes <E> WD <E> WD No 1 3/4" 2' - 10" 7' - 0" 28 <E> DOOR
115 Yes <E> WD <E> WD No 1 3/4" 3' - 0" 7' - 0" 13
200B Yes <E> WD <E> WD No 1 3/4" 3' - 0" 7' - 0" 03
200D Yes <E> WD <E> WD No 1 3/4" 2' - 4" 7' - 0" 13
200E Yes <E> WD <E> WD No 1 3/4" 2' - 4" 7' - 0" 13
201 Yes <E> WD <E> WD No 2" 6' - 2" 6' - 8" 29
201B Yes A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 17 REFRAME AND INSTALL SALVAGED DOOR AT FLOOR LEVEL REPAIR PLASTER AND INSTALL SALVAGED DOOR
TRIM ON BOTH SIDES.
201C No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 07
201D No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 22
201E No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 30
202 Yes <E> WD <E> WD No 1 3/4" 3' - 0" 7' - 0" 14
202A No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 13
202B No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 22
202C Yes <E> WD <E> WD No 1 3/4" 2' - 10" 7' - 0" 25 <E> DOOR
202D No SEE ELEV WD B WD Yes 1 3/8" 3' - 2" 8' - 5" 32 NEW EXTERIOR WOOD DOOR: VERIFY OPENING SIZE
203 Yes <E> WD <E> WD No 1 3/4" 2' - 10" 7' - 0" 22 <E> DOOR
203B Yes A WD A WD No 1 3/4" 3' - 0" 7' - 0" 11 INSTALL SALVAGED DOOR IN SAME OPENING WITH DOOR SWING AS SHOWN.
203C No - WD E WD No 1 3/4" 3' - 0" 3' - 0" 05 ADD ALT #2: HALF-HEIGHT SWINGING GATE
204 Yes <E> WD <E> WD No 1 3/4" 3' - 0" 7' - 0" 08
204A No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 13
204B Yes <E> WD <E> WD No 1 3/4" 3' - 0" 7' - 0" 08
205 Yes <E> WD <E> WD No 1 3/4" 3' - 2" 7' - 0" 08
206 Yes <E> WD <E> WD No 1 3/4" 3' - 2" 7' - 0" 33
206A Yes <E> WD <E> WD No 1 3/4" 3' - 0" 7' - 0" 34
207 No A WD A WD Yes 1 3/4" 3' - 0" 7' - 0" 08 NEW DOOR AND TRANSOM
DRAWINGS BASED ON FLOOR PLANS
PROVIDED BY PITKIN COUNTY. CONTRACTOR
TO NOTIFY ARCHITECT OF ANY DEVIATIONS
FROM ACTUAL FIELD CONDITIONS, PRIOR TO
COMMENCING WITH WORK.
GENERAL NOTES
1. SALVAGE AND REUSE EXISTING DOORS WHERE NOTED
2. AT ALL SALVAGED WOOD DOORS PROVIDE NEW HARDWARE
3. ALL NEW WOOD DOORS SHALL BE SOLID WOOD STILE AND RAIL WOOD
DOORS WITH RAISED WOOD PANELS AS INDICATED WITH CLEAR FINISH
4. ALL GLAZING WITHIN DOORS OR WITHIN 24INCHES OF DOOR SHALL BE
SAFETY GLAZING.
5. CONTRACTOR SHALL FIELD VERIFY ALL OPENINGS PRIOR TO COMMENCING
WORK.
6. REFER TO SPECIFICATIONS FOR DOOR HARDWARE.
1
1
No. Description Date
1 ADDENDUM 01 4/26/2019
08/21/2019
HALL
16
17<N> POST MOUNTED
AUTOMATIC ACCESSIBLE
DOOR OPENER BUTTON
LOCATION (EXTERIOR)
UP
3
A7.3
LIFT
5
A7.3
USGS = 7,912.2'
USGS = 7,911.54'
ALIGN <N> CONCRETE LANDING
WITH <E> SIDEWALK -DOWEL INTO
<E> SIDEWALK WITH #3 REBAR AT
12" O.C. WITH 6" MIN. EMBED - <N>
LANDING NOT TO EXCEED 2%
SLOPE IN ANY DIRECTION, RE: CIVIL
<N> CONCRETE RAMP NOT TO
EXCEED 1:12 SLOPE IN RUNNING
DIRECTION AND NOT TO EXCEED 2%
CROSS SLOPE, RE: CIVIL
PROVIDE <N> PRE-FINISHED PIPE
HANDRAIL TO 36" MIN. AFF (TO TOP
OF RAIL)WITH VERTICAL POST AT
4'-0" O.C. - PROVIDE 12" MIN. RAIL
EXTENSIONS AT TOP AND BOTTOM
OF RAMP
<N> PERMEABLE PAVING AT
LANDING AT NEW DOOR LOCATION -
NEW LANDING NOT TO EXCEED 2%
SLOPE IN ANY DIRECTION, RE: CIVIL
5'
-
0
"
RAMP NOT TO EXCEED 1:20
9' - 2 1/2"
LANDING
5' - 0"
CLR
5' - 0"
<E>SIDEWALK TO
REMAIN
<E> STAIR AND WALL
TO REMAIN
MIN.
12"
<N> WALL MOUNTED
AUTOMATIC ACCESSIBLE
DOOR OPENER BUTTON
LOCATION (INTERIOR)
PRE-FINISHED GATE
ASSEMBLY BY LIFT MFG
INSTALLED BY G.C.
PRE-FINISHED LIFT
ASSEMBLY - INSTALLED
BY G.C.
FIN. TO STUD
1' - 3"STUD TO STUD
5' - 3" (V.I.F.)
<N> CARPET ON <N>
CONC. FLOOR
<E> DOOR TO
REMAIN, PROVIDE
POWER ASSISTED
OPENER
T-SHAPED TURNING
CLEARANCE
SECURE <E>
WROUGHT IRON GATE
IN THE OPEN POSITION
6" CONCRETE CURB
3' - 0"
<E> FENCE TO REMAIN
<E> FENCE TO REMAIN
<E> WINDOW TO
REMAIN
HOLD
3' - 6"
DOOR PROVIDED BY LIFT
MFG INSTALLED BY G.C.
4
A7.4
Sim
3
PROVIDE 6INCH CONC BOARDER:
REF CIVIL
36" CLEAR
4
CLOSET
108F
DN
SECURE <E>
WROUGHT IRON GATE
IN THE OPEN POSITION
3
A7.3
LIFT5
A7.3
TO BE REMOVED AND SALVAGED
<E> DOOR LOCATION
(V.I.F.)
1' - 7"
<N> CLR OPENING
4' - 9"
,<E> STAIR AND
LANDING TO REMAIN
<E> ENTRY VESTIBULE
OPEN TO
BELOW
(V.I.F.)
4' - 8"
(V.I.F.)
5' - 5 1/2"
(V.I.F.)
1' - 10"
ADA CLEAR FLOOR
SPACE
<E> WINDOW AND
FRAME TO REMAIN
FIN. TO STUD
4' - 0" (V.I.F.)
<N> STRUCTURAL
FLOOR AT LIFT
PLATFORM LOCATION
<N> ENCLOSURE AT
LIFT WALL
PRE-FINISHED LIFT -
INSTALLED BY G.C.
<E> MECHANICAL
DUCT TO REMAIN
NOTE: NEW WALL FRAMING AT LIFT LOCATION SHALL BE (1) HOUR RATED
(SHOWN WITH DIAGONAL CROSS HATCH)
STEEL FRAMING: GA FILE NO WP1072
WOOD FRAMING: GA FILE NO WP 2510
42" CLEAR 4
GARDEN LEVEL
100' - 0"
MAIN LEVEL
110' - 3 5/8"
<E>FOUNDATION
WALL TO REMAIN
<N> PERMEABLE
PAVING LANDING.
SLOPE LANDING
MAX 2% AWAY
FROM BUILDING
<E> WINDOW
AND FRAME TO
REMAIN
WALKOFF CARPET
FINISH ON CONC
PRE-FINISHED
GATE ASSEMBLY
PROVIDED BY
FROM LIFT MFG.
OFFSET FLOOR
STRUCTURE SO THAT
FINISH FLOOR OF FLOOR
STRUCTURE AND LIFT
PLATFORM ALIGN WITH
NO VERTICAL
TRANSITION.
COORDINATE WITH LIFT
MANUFACTURER
<N> WALL 2X WD.
WALL CONSTRUCTION
WITH HIGH IMPACT
RESISTANT GYP. BD.
ON PUBLIC SIDE OF
WALL BEYOND
COMMERCIAL
WHEELCHAIR LIFT
EXISTING WALL TO REMAIN
<N> WALL
ENCLOSURE
BEYOND AT LIFT
<N> FLOOR STRUCTURE
BEYOND, RE: STRUC
INSTALL PRE-
FINISHED GATE
ASSEMBLY FROM
LIFT MFG.
PROVIDE NEW WD
1X TRIM CLOSER
AT EXISTING
FLOOR - STN
5
A7.3
FIN. TO STUD
1' - 1"
A5.2
1
V.I.F.
4' - 5 1/2"
V.I.F.
4' - 7 1/2"
A5.2
4 Sim
DOOR PROVIDED
BY FROM LIFT
MFG.
REPAIR <E>
PLASTER WALL
BEYOND - PT
3
GARDEN LEVEL
100' - 0"
MAIN LEVEL
110' - 3 5/8"
3
A7.3
(V.I.F.)
4' - 5 1/2"
<E> MASONRY WALL TO REMAIN
ALIGN FLOOR STRUCTURE AND LIFT SO
THAT PLATFORM OF LIFT ALIGNS WITH
FLOOR BEYOND
<N> WALL CONSTRUCTION WITH
IMPACT RESISTANT GYP. BOARD
FINISH ON PUBLIC SIDE OF LIFT
ENCLOSURE
INSTALL <N> CARPET FINISH ON <N>
JOIST WITH 3/4" T&G PLYWD -ALIGN <N>
FLOOR WITH <E> MAIN FLOOR
<N> WALL ENCLOSURE
JAMB OF <N> OPENING BEYOND
<E> MASONRY WALL TO REMAIN, RE:
STRUC
INSTALL <N> CARPET
FINISH ON <N> FLOOR, RE:
STRUC. ALIGN <N> FLOOR
FINISH WITH <E> MAIN
FLOOR
<N> WALL CONSTRUCTION WITH
5/8" IMPACT RESISTANT GYP. BD.
FINISH ON PUBLIC SIDE OF LIFT
ENCLOSURE AND 5/8" GYP. BD.
ON CLOSET SIDE
<N> WALL CONSTRUCTION
WITH 5/8" IMPACT RESISTANT
GYP. BOARD FINISH ON
PUBLIC SIDE OF LIFT
ENCLOSURE AND 5/8" GYP.
BOARD ON STORAGE SIDE
LIFT ASSEMBLY AND LIFT
PLATFORM
(V.I.F)
5' - 10"
FIN. TO STUD
3' - 6" (V.I.F.)
<E> WALL TO REMAIN
INSTALL 1x8 WD BASE BD. WITH
3/4" QUARTER ROUND TRIM
<E> FLOOR TO REMAIN
HALL
16
CLOSET
108F
DOOR AS PART OF THE LIFT
BEYOND
RUBBER BASE AT STORAGE
<N> WD BASE - PT TO MATCH <E>
Project Number
Date
Drawn by
Checked by
Anderson Hallas
Architects, PC
ARCHITECTURE
HISTORIC PRESERVATION
COPYRIGHT 2019
ANY UNAUTHORIZED USE OF THESE DOCUMENTS
IS PROHIBITED WITHOUT THE WRITTEN CONSENT
OF:
ANDERSON HALLAS ARCHITECTS, P.C.
PLANNING
Issue
715 FOURTEENTH STREET
GOLDEN, COLORADO 80401
(303) 278-4378
FAX (303) 278-0521
Scale AS NOTED
8/14/2019 6:15:40 PM
A7.3
ENLARGED PLANS
AT NEW LIFT
ENTRY
2017910
PITKIN COUNTY
COURTHOUSE REMODEL
PITKIN COUNTY, CO
5/2/19
DAM
RAS/NAA
506 E Main St St 300, Aspen, CO 81611
PERMIT
1/4" = 1'-0"1 GARDEN LEVEL LIFT PLAN
1/4" = 1'-0"2 MAIN LEVEL LIFT PLAN
1/2" = 1'-0"3 BUILDING SECTION - NEW ADA LIFT ENTRY 4 3D-Cube - ISO
1/2" = 1'-0"5 BUILDING SECTION AT NEW ADA LIFT ENTRY
<N> LIFT ENCLOSURE
<N> FLOOR STRUCTURE, RE:
STRUC
INSTALL <N> LIFT ASSEMBLY
AND LIFT PLATFORM
<E>GARDEN LEVEL FLOOR
TO REMAIN
LIFT DOOR PROVIDED BY LIFT
MANUFACTURER
<N> EXTERIOR DOOR, RE: TO
DOOR SCHEDULE AND JAMB
DETAILS FOR ADDITIONAL
INFORMATION
<N> ACCESSIBLE LANDING WITH
PERMEABLE PAVERS AT <N>
DOOR LOCATION - SLOPE
LANDING MAX 2%AWAY FROM
BUILDING, RE: CIVIL
DRAWINGS BASED ON FLOOR PLANS
PROVIDED BY PITKIN COUNTY. CONTRACTOR
TO NOTIFY ARCHITECT OF ANY DEVIATIONS
FROM ACTUAL FIELD CONDITIONS, PRIOR TO
COMMENCING WITH WORK.
NOTE:
CONTRACTOR TO LAYOUT
RAMP PRIOR TO
EXCAVATION TO ASSURE
EXISTING GATE LOCATION
WORKS WITH SLOPE
MINIMUM AND MAXIMUM
CLEARANCES
<N> FLOOR STRUCTURE, RE:
STRUC
2
No. Description Date
2 ADDENDUM 02 5/29/2019
3 ADDENDUM 03 6/12/2019
4 BUILDING
COMMENTS
8/14/2019
3
08/21/2019
A9.2 2 1'
-
1
1
1
/
2
"
2'
-
6
"
3"
2' - 1"
2
A9.11
Sim
FINISHED
FACE PANEL
<E> COLUMN TO
REMAIN, LOCATION
V.I.F.
30
"
X
4
8
"
CL
E
A
R
S
P
A
C
E
(E) SIGNAGE, MODIFY TO ACCOMODATE
(N) ROOM NAME, COMPLY W/ ADA
PROVIDE <N> OR RELOCATED
FLAG SIGNAGE AT THE
FOLLOWING ROOMS:
• 05
• 102A
• 105C
• 108A
• 101A
• 201
• 203
PROVIDE <N> OR RELOCATED
WALL SIGNAGE TO MATCH
EXISTING AT ALL ROOMS.
SOLID SURFACE
COUNTERTOP WITH
INTEGRAL 4" BACKSPLASH
2
A9.11
Sim
2' - 11"
FINISHED FACE PANEL;
BEHIND COLUMN
<E> COLUMN TO REMAIN,
LOCATION V.I.F.
FILLER
PROVIDE REMOVABLE
ACCESSIBLE APRON TO MATCH
CASEWORK. CONCEAL PIPING AND
PROVIDE KNEE PROTECTION.
4
4
30" MIN VIF
A9.2
7
BC30 BC30 DW24 SB36 3'-0" MIN. CLR
2'
-
1
"
DW
REF.
3
A9.11
Sim1
A9.11
Sim
30" X 48"
CLEAR SPACE
2'
-
1
0
"
WC24 WC30 WC30
MIN. CLR.
3' - 3"
BC36BC36REF.
SOLID SURFACE
COUNTERTOP WITH
INTEGRAL 4"
BACKSPLASH; SCRIBE TO
ADJACENT STONE
3
A9.11
Sim 1
A9.11
Sim
FILLER; SCRIBE TO
ADJACENT STONE
FILLER; SCRIBE TO
ADJACENT STONE
30" CLEAR
SB36 DW24
4
PROVIDE REMOVABLE ACCESSIBLE APRON
TO MATCH CASEWORK. CONCEAL PIPING
AND PROVIDE KNEE PROTECTION.
4
CABINET LEGEND
BC =BASE CABINET
SB =SINK BASE
DW =DISHWASHER
TC =TALL CABINET
WC =WALL CABINET
REF =REFRIGERATOR
BC15
30" CLEAR MIN
3' - 0"
2'
-
1
0
"
SOLID SURFACE
COUNTERTOP WITH
INTEGRAL 4" BACKSPLASH
2
A9.11
Sim
FINISHED END PANELS
PROVIDE REMOVABLE ACCESSIBLE APRON
TO MATCH CASEWORK. CONCEAL PIPING
AND PROVIDE KNEE PROTECTION.
4
4
A9.25
1'
-
3
"
3'
-
0
"
1"
2' - 0 1/2"
2
A9.11
Sim
PROVIDE A FINISHED END
PANEL
30
"
X
4
8
"
CL
E
A
R
S
P
A
C
E
FINISHED END PANEL
Project Number
Date
Drawn by
Checked by
Anderson Hallas
Architects, PC
ARCHITECTURE
HISTORIC PRESERVATION
COPYRIGHT 2019
ANY UNAUTHORIZED USE OF THESE DOCUMENTS
IS PROHIBITED WITHOUT THE WRITTEN CONSENT
OF:
ANDERSON HALLAS ARCHITECTS, P.C.
PLANNING
Issue
715 FOURTEENTH STREET
GOLDEN, COLORADO 80401
(303) 278-4378
FAX (303) 278-0521
Scale AS NOTED
8/
1
4
/
2
0
1
9
6
:
1
5
:
4
1
P
M
A9.2
INTERIOR
ELEVATIONS
2017910
PITKIN COUNTY
COURTHOUSE REMODEL
PITKIN COUNTY, CO
5/2/19
LWB
RAS/NAA
506 E Main St St 300, Aspen, CO 81611
PERMIT
1/2" = 1'-0"1 JURY DELIB. 03 ENLARGED PLAN DRAWINGS BASED ON FLOOR PLANS
PROVIDED BY PITKIN COUNTY. CONTRACTOR
TO NOTIFY ARCHITECT OF ANY DEVIATIONS
FROM ACTUAL FIELD CONDITIONS, PRIOR TO
COMMENCING WITH WORK.
0 2' 4'
1 1/2" = 1'-0"3 EXISTING SIGNAGE
1/2" = 1'-0"2 JURY DELIB. 03 INTERIOR ELEVATION EAST
1/2" = 1'-0"6 BREAK RM 02A ENLARGED PLAN
1/2" = 1'-0"7 BREAK RM 02A INTERIOR ELEVATION SOUTH
1/2" = 1'-0"5 JURY DELIB. 204 INTERIOR ELEVATION WEST
1/2" = 1'-0"4 JURY DELIB. 204 ENLARGED PLAN
1
No. Description Date
1 ADDENDUM 01 4/26/2019
4 BUILDING
COMMENTS
8/14/2019
08/21/2019
WC36 WC12WC36
BC24BC24SB36
SOLID SURFACE
COUNTERTOP WITH
INTEGRAL 4"
BACKSPLASH
1
A9.11
Sim2
A9.11
Sim
3' - 0"
PROVIDE REMOVABLE, ACCESSIBLE
APRON TO MATCH CASEWORK,
CONCEAL PIPING AND PROVIDE
NEW PROTECTION
BC24
2'
-
1
0
"
SOLID SURFACE
COUNTERTOP WITH
INTEGRAL 4"
BACKSPLASH
1
A9.11
Sim
TC30
101E
WC24
REF.
2' - 0"
APT. SIZE REF.
PROVIDED BY OWNER
CABINET LEGEND
BC =BASE CABINET
SB =SINK BASE
DW =DISHWASHER
TC =TALL CABINET
WC =WALL CABINET
REF =REFRIGERATOR
A9.7
2
3
BC
2
4
TC
3
0
SB36 2' - 0" CLR.BC24
1'
-
1
0
"
1' - 10"
2
A9.11
Sim 1
A9.11
Sim
1
A9.11
Sim
30" X 48"
CLEAR SPACE
REF.2'
-
0
"
APT. SIZE REF.
PROVIDED BY OWNER
EQ EQ
101F
101F
EQ EQ
7'
-
3
"
7'
-
3
"
101C 101A
101C 101B101D
101B
5' - 0 1/2"
7'
-
2
"
101E 101D
7'
-
3
"
5' - 1 1/2"
Project Number
Date
Drawn by
Checked by
Anderson Hallas
Architects, PC
ARCHITECTURE
HISTORIC PRESERVATION
COPYRIGHT 2019
ANY UNAUTHORIZED USE OF THESE DOCUMENTS
IS PROHIBITED WITHOUT THE WRITTEN CONSENT
OF:
ANDERSON HALLAS ARCHITECTS, P.C.
PLANNING
Issue
715 FOURTEENTH STREET
GOLDEN, COLORADO 80401
(303) 278-4378
FAX (303) 278-0521
Scale AS NOTED
8/
1
4
/
2
0
1
9
6
:
1
5
:
4
5
P
M
A9.7
INTERIOR
ELEVATIONS - DA
2017910
PITKIN COUNTY
COURTHOUSE REMODEL
PITKIN COUNTY, CO
5/2/19
LWB
RAS/NAA
506 E Main St St 300, Aspen, CO 81611
PERMIT
DRAWINGS BASED ON FLOOR PLANS
PROVIDED BY PITKIN COUNTY. CONTRACTOR
TO NOTIFY ARCHITECT OF ANY DEVIATIONS
FROM ACTUAL FIELD CONDITIONS, PRIOR TO
COMMENCING WITH WORK.
0 2' 4'
1/2" = 1'-0"2 DA 101 INTERIOR ELEVATION NORTH
1/2" = 1'-0"3 DA 101 INTERIOR ELEVATION EAST
1/2" = 1'-0"1 DA 101 ENLARGED PLAN
1/2" = 1'-0"4 DA OFFICE 101 NORTH
1/2" = 1'-0"5 DA OFFICE 101 SOUTH
1/2" = 1'-0"6 OFFICE 101 WEST
1/2" = 1'-0"7 OFFICE 101 C EAST
No. Description Date
4 BUILDING
COMMENTS
8/14/2019
4
08/21/2019
A
FRONT
VIEW
SIDE
VIEW
B
FRONT
VIEW
SIDE
VIEW
23
"
*
(2
0
"
M
I
N
)
(4
4
"
M
A
X
)
C
FRONT
VIEW
SIDE
VIEW
44
"
*
(4
0
"
M
I
N
.
)
(4
8
"
M
A
X
)
F
FRONT
VIEW
SIDE
VIEW
(4
0
"
M
I
N
.
)
(4
8
"
M
A
X
)
SIDE
VIEW
J
FRONT
VIEW
WALL
MOUNTED
SINK
33
"
*
(3
4
"
M
A
X
)
(4
0
"
M
A
X
)
RI
M
O
F
SI
N
K
BO
T
T
O
M
OF
M
I
R
R
O
R
CL
E
A
R
F
L
O
O
R
SP
A
C
E
ACCESSIBLE FLOOR
MOUNTED WATER CLOSET
SIDE
VIEW
FRONT
VIEW
TOP OF SEAT
AUTOMATIC FLUSH
VALVE
18
"
*
(1
7
"
M
I
N
)
(1
9
"
M
A
X
)
38
"
*
48
"
M
A
X
18
"
M
I
N
ACCESSIBLE WALL
MOUNTED LAVATORY
PROVIDE UNDER LAVATORY
PLUMBING PROTECTION
TOILET TISSUE
DISPENSER
RECESSED PAPER
TOWEL DISPENSER AND
WASTE RECEPTACLE
SOAP DISPENSER
MAX
12"42" MIN
40" *
(39" MIN)
(41" MAX)
34
"
*
(3
3
"
M
I
N
)
(3
6
"
M
A
X
)
KEEP 1 1/2" AREA
BELOW BAR CLEAR
KEEP 18"
AREA ABOVE
BAR CLEAR
MIN
12"
MIN
24"
34
"
*
(3
3
"
M
I
N
)
(3
6
"
M
A
X
)
ACCESSIBLE WALL ATTACHED GRAB BARS
24" MIN
42" MAX
MIN
18
"
PROTRUDING DISPENSER
BELOW GRAB BAR
SANITARY
NAPKIN
DISPOSAL
1) ALL ACCESSIBLE FIXTURE AND ACCESORIES SHALL BE
MOUNTED IN COMPLIENCE WITH ADA
2) ALL LAVATORIES SHALL HAVE UNDERLAVATORY KNEE
AND LEG PROTECTION
3) ALL FAUCETS SHALL BE ADA CERTIFIED
4)WHERE TOILET ACCESSORIES TRANSITION FROM
CERAMIC TILE TO GWB, SHIM TO PROVIDE CONSISTANT
INSTALLATION.
* = PREFERED MOUNTING HEIGHT
FRONT
VIEW
SIDE
VIEW
RECESSED MOUNT
WASTE RECEPTICLES
MAX
4"
48
"
C
4" MAX
MIN
36"
54" MIN
17" - 19"
16" - 18"
AMBULATORY STALL
3'
-
8
"
*
41
M
A
X
39
"
M
I
N
18
"
D D.2D.1 D D.1D.2
D
D.1D.2
GENERAL NOTES
9"
2'
-
3
"
8"3"
1'
-
6
"
11"
1"
40" *
(39" MIN)
(41" MAX)
34
"
*
(3
3
"
M
I
N
)
(3
6
"
M
A
X
)
KEEP 1 1/2" AREA
BELOW BAR CLEAR
KEEP 18"
AREA ABOVE
BAR CLEAR
41
M
A
X
39
"
M
I
N
18
"
D.1D.3D
ACCESSIBLE WALL/FLOOR ATTACHED
GRAB BAR
54" MIN
A9.8
3
6
5
4
1'
-
6
"
07
<N> 5/8" GWB OVER
1 1/2" FURRING
B
ADD.2 D.1
E
C
1'
-
6
"
F
5'
-
0
"
D
B
A
D.2
D.1
C
J
2' - 0"
3'
-
0
"
1' - 6"
E
5'
-
0
"
D
A
D.2
D.1
1' - 6"
F
G
H
J
5'
-
0
"
E
F
G
H
J
5'
-
0
"
C
B
G
J
Project Number
Date
Drawn by
Checked by
Anderson Hallas
Architects, PC
ARCHITECTURE
HISTORIC PRESERVATION
COPYRIGHT 2019
ANY UNAUTHORIZED USE OF THESE DOCUMENTS
IS PROHIBITED WITHOUT THE WRITTEN CONSENT
OF:
ANDERSON HALLAS ARCHITECTS, P.C.
PLANNING
Issue
715 FOURTEENTH STREET
GOLDEN, COLORADO 80401
(303) 278-4378
FAX (303) 278-0521
Scale AS NOTED
8/
1
4
/
2
0
1
9
6
:
1
5
:
5
1
P
M
A9.8
TYP. RR ACCESS
AND RR INTERIOR
ELEVATIONS
2017910
PITKIN COUNTY
COURTHOUSE REMODEL
PITKIN COUNTY, CO
5/2/19
LWB
RAS/NAA
506 E Main St St 300, Aspen, CO 81611
PERMIT
DRAWINGS BASED ON FLOOR PLANS
PROVIDED BY PITKIN COUNTY. CONTRACTOR
TO NOTIFY ARCHITECT OF ANY DEVIATIONS
FROM ACTUAL FIELD CONDITIONS, PRIOR TO
COMMENCING WITH WORK.
0 2' 4'
3/8" = 1'-0"1 TOILET ACCESSORIES MOUNTING HEIGHTS
1/2" = 1'-0"2 JURY RR 07
1/2" = 1'-0"3 JURY 07 NORTH
1/2" = 1'-0"6 JURY 07 EAST
1/2" = 1'-0"5 JURY 07 SOUTH
1/2" = 1'-0"4 JURY 07 WEST
TOILET ACCESSORY SCHEDULE
A NEW STAINLESS STEEL DOUBLE TOILET PAPER DISPENSER
B NEW STAINLESS STEEL AUTOMATIC PAPER TOWEL DISPENSER
C NEW STAINLESS STEEL FREE-STANDING WASTE RECEPTACLE
D 18" MIN. x 1-1/2" DIA. VERTICAL GRAB BARS
D.1 36" LG. x 1-1/2" DIA. REAR WALL GRAB BARS
D.2 42" MIN. x 1-1/2" DIA. SIDE WALL GRAB BAR
D.3 54" MIN. x 1-1/2" DIA. SIDE WALL FLOOR ATTACHED GRAB BAR
E NEW WD FRAMEMIRROR (SEE ELEVATION FOR SIZE) SHIM BEHIND MIRROR FOR
FLUSH INSTALLATION OVER TILE
F NEW WALL MOUNTED LIQUID SOAP DISPENSER
G STAINLESS STEEL EDGING ON ALL EXPOSED TILE EDGES
H PIPE PROTECTION COVER UNDER LAV.
J PORCELAIN WALL TILE SUBWAY PATTERN
No. Description Date
08/21/2019
RUBBER BASE
PLAM FLAT PANEL LOCKABLE DOOR
SOLID SURFACE
COUNTERTOP &
INTEGRAL BACKSPLASH
2X BLOCKING
BLOCKING
BLOCKING
CABINET BACK
4"4"
DRAWER PULL
ADJUSTABLE MELAMINE SHELF
TY
P
.
2'
-
1
0
"
VARIES
4"
PRE-MANUFACTURED PLAM BASE
CABINET WITH MELAMINE
INTERIOR
TY
P
.
2'
-
6
"
ADJUSTABLE MELAMINE SHELF
HOLES W/ MTL SHELF
SUPPORTS
TYP.
1' - 8"
DOOR PULL
PLAM FLAT FRONT CABINET DOOR
VARIES
SOLID SURFACE
COUNTERTOP AND
INTEGRAL BACKSPLASH
RUBBER BASE
BLOCKING
MELAMINE INTERIOR
FINISH (WHITE)
1/4" RADIUS EDGE
5 1/2"
MIN.
2' - 3"
SINK, RE: MECHANICAL.
6" MAX. DEPTH
2' - 10"
MIN.
9"
MIN.
8"
MIN.
11"
BLOCKING
PIPE SHIELDING INSULATION
ON ALL PLUMBING LINES
BELOW SINK
WD FALSE DRAWER
PANEL
1 1/2"
(N) OR (E) GWB OR
PLASTER WALL, V.I.F
REMOVABLE APRON TO MATCH
CASEWORK TO CONCEAL
PIPING AND PROVIDE KNEE
PROTECTION
SOLID SURFACE
COUNTERTOP AND
INTEGRAL BACKSPLASH
RUBBER BASE
BLOCKING
MELAMINE INTERIOR
FINISH (WHITE)
1/4" RADIUS EDGE
2' - 10"
BLOCKING
PIPE SHIELDING
INSULATION ON
ALL PLUMBING
LINES BELOW
SINK
<E> MASONRY
WALL
<N> FURRED OUT
WALL. SEE WALL
TYPES
SINK, RE: MECHANICAL.
6" MAX. DEPTH
WD FALSE DRAWER
PANEL
REMOVABLE APRON TO MATCH
CASEWORK TO CONCEAL
PIPING AND PROVIDE KNEE
PROTECTION
1 1/2"
5 1/2"
MIN.
2' - 3"
MIN.
8"
MIN.
11"
MIN.
9"
4
RUBBER BASE
PLAM, FLAT PANEL,
LOCKABLE DRAWERS, 4
THUS
SOLID SURFACE
COUNTERTOP
2X BLOCKING
BLOCKING
BLOCKING
CABINET BACK
4"
DRAWER PULL.
VARIES
1'-6 1/2" U.N.O.
4"
PREMANUFACTURED P-LAM
BASE CABINET WITH
MELAMINE INTERIOR
CABINET BACK
RUBBER BASE
P-LAM FLAT PANEL
LOCKABLE DRAWER
SOLID SURFACE
COUNTERTOP
2X BLOCKING
BLOCKING
BLOCKING
CABINET BACK
4"4"
DRAWER PULL
VARIES
1'-6 1/2" U.N.O.
P-LAM BASE CABINET WITH
MELAMINE INTERIOR
LINE WORK SHOWN FOR CLARITY ~ PROVIDE
TWO (2) DRAWERS TO FIT STANDARD SIZE
(9-5/8" x 11-3/4") HANGING FILE FOLDERS
P-LAM FLAT PANEL
LOCKABLE DRAWER
Project Number
Date
Drawn by
Checked by
Anderson Hallas
Architects, PC
ARCHITECTURE
HISTORIC PRESERVATION
COPYRIGHT 2019
ANY UNAUTHORIZED USE OF THESE DOCUMENTS
IS PROHIBITED WITHOUT THE WRITTEN CONSENT
OF:
ANDERSON HALLAS ARCHITECTS, P.C.
PLANNING
Issue
715 FOURTEENTH STREET
GOLDEN, COLORADO 80401
(303) 278-4378
FAX (303) 278-0521
Scale AS NOTED
8/14/2019 6:15:53 PM
A9.11
CASEWORK
DETAILS
2017910
PITKIN COUNTY
COURTHOUSE REMODEL
PITKIN COUNTY, CO
5/2/19
LWB
RAS/NAA
506 E Main St St 300, Aspen, CO 81611
PERMIT
DRAWINGS BASED ON FLOOR PLANS
PROVIDED BY PITKIN COUNTY. CONTRACTOR
TO NOTIFY ARCHITECT OF ANY DEVIATIONS
FROM ACTUAL FIELD CONDITIONS, PRIOR TO
COMMENCING WITH WORK. 1 1/2" = 1'-0"1 ADA CASEWORK
1 1/2" = 1'-0"2 ADA SINK CABINET
1 1/2" = 1'-0"3 ADA SINK CABINET ON FURRED WALL
1 1/2" = 1'-0"4 ADMIN BASE CABINET - 4 DRAWER
1 1/2" = 1'-0"5 ADMIN CASE CABINET - FILING CABINET
No. Description Date
4 BUILDING
COMMENTS
8/14/2019
4
08/21/2019
CHECK VALVE
2WAY ATC VALVE
3WAY ATC VALVE
BALANCING VALVE
BUTTERFLY VALVE
MECHANICAL LEGEND
PRESSURE REDUCING VALVE
EXISTING ITEMS TO
CONNECTION TO EXISTING
BE DEMOLISHED
EXISTING ITEMS
SAFTEY RELIEF VALVE
BACK FLOW PREVENTER
NEW WORK
PRESSURE SENSOR
THERMOSTAT
METER
P&T TAP
FLOW ARROW
IN LINE PUMP
VENTURI TYPE BALANCING VALVE
TEMPERATURE SENSOR
THERMOMETER
AUTOMATIC AIR VENT
GAUGE
MANUAL AIR VENT
GRADE CLEAN OUT
FLOOR CLEAN OUT
WALL CLEAN OUT
FLOW SENSOR
STRAINER
DRAIN VALVE
FLEXIBLE CONNECTION
UNION
CAP
FLOOR SINK
FLOOR DRAIN
PIPING SERVICES
PIPING SYSTEM COMPONENTS
TEE UP
TEE DOWN
CHWS
HWR
G
CA
HWS
CHWR
CD
ELBOW DOWN
ELBOW UP
DOMESTIC HOT WATER RECIRC
DOMESTIC COLD WATER
DOMESTIC HOT WATER
VENT
WASTE
DRAWING NOTATION
CHILLED WATER SUPPLY
CONDENSATE DRAIN
HEATING WATER RETURN
HEATING WATER SUPPLY
CHILLER WATER RETURN
COMPRESSED AIR
NATURAL GAS
GATE VALVE
PLUG VALVE
BALL VALVE
VALVES
DIFFUSER CALLOUT
SUPPLY DIFFUSER W/
FIRE/SMOKE DAMPER
DESIGNATION
SCHEDULE
CFM
NECK SIZE
10"∅
375
FLEX CONNECTION
SLOT DIFFUSER
ECCENTRIC REDUCER
HVAC SYSTEM COMPONENTS
MOTORIZED DAMPER
RECT. RETURN DUCT
RECT. SUPPLY DUCT
SUPPLY DIFFUSER/
DN
RETURN GRILLE
DUCT SLOPE
M
18x12 RECT.
12"ROUND
MANUAL DAMPER
(R)RELOCATED
(N)NEW
(E)EXISTING
THREE WAY CONTROL VALVE
MECHANICAL NOTES
I. GENERAL
A. ALL WORK SHALL BE IN ACCORDANCE WITH SMACNA STANDARDS AND SPECIFICATIONS, AND LOCAL AUTHORITY HAVING
JURISDICTION.
B. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND NOT INTENDED TO SHOW ALL TRANSITIONS, OFFSETS, ETC.
CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND PROVIDE ALL NECESSARY FITTINGS TO COMPLETE THE INTENT
OF THE DRAWINGS. ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS SHALL BE REPORTED TO THE ENGINEER
FOR RESOLUTION. CONTRACTOR MAY LOCATE MECHANICAL EQUIPMENT DIFFERENTLY THAN SHOWN ON DRAWINGS DUE TO
CONFLICTS, AS LONG AS FUNCTION AND/OR APPEARANCE ARE NOT AFFECTED.
C. COORDINATE SPACE REQUIREMENTS, SUPPORTS, AND INSTALLATION OF MECHANICAL WORK, WHICH ARE INDICATED
DIAGRAMMATICALLY ON THE DRAWINGS. FOLLOW ROUTING SHOWN FOR PIPES AND DUCTS AS CLOSELY AS PRACTICABLE;
PLACE RUNS PARALLEL WITH LINES OF BUILDING. UTILIZE SPACES EFFICIENTLY TO MAXIMIZE ACCESSIBILITY FOR OTHER
INSTALLATIONS, FOR MAINTENANCE, AND FOR REPAIRS.
D. COMPLY WITH MANUFACTURER'S INSTRUCTIONS INCLUDING EACH STEP IN SEQUENCE. SHOULD MANUFACTURERS'
INSTRUCTIONS CONFLICT WITH THE DRAWINGS, REQUEST CLARIFICATION FROM THE ENGINEER BEFORE PROCEEDING.
E. DUCT SIZES ARE INSIDE DIMENSION.
F. CONTRACTOR SHALL REVIEW THESE DOCUMENTS CAREFULLY. CONTRACTOR SHALL CONTACT THREE SIXTY (360)
ENGINEERING, INC. (303-940-2050), FOR RESOLUTION OF ANY DISCREPANCIES, OMISSIONS, OR CLARIFICATIONS, BEFORE BID
DATE. IN THE EVENT THAT AN INTERPRETATION OF BID DOCUMENTS IS NECESSARY AFTER THE BID DATE, THE DECISION OF 360
SHALL BE FINAL AND BINDING.
G. PRODUCT DELIVERY, STORAGE, AND HANDLING: PROVIDE EQUIPMENT AND PERSONNEL TO HANDLE PRODUCTS BY METHODS TO
PREVENT DAMAGE. PROMPTLY INSPECT SHIPMENTS TO ENSURE THAT PRODUCTS ARE UNDAMAGED. STORE AND PROTECT
PRODUCTS IN ACCORDANCE WITH MANUFACTURERS' INSTRUCTIONS.
H. ALL REMOVED EQUIPMENT SHALL REMAIN THE PROPERTY OF THE BUILDING MANAGER AND SHALL BE STORED PER THEIR
DIRECTION.
I. THE CONTRACTOR IS RESPONSIBLE FOR THE COSTS OF ALL CHANGE ORDERS, WHICH THE OWNER AND ENGINEER HAVE NOT
APPROVED IN WRITING PRIOR TO THE EXECUTION OF THE ASSOCIATED WORK.
J. IN THE CASE OF A CONFLICT, UNLESS OTHERWISE NOTED, KEYNOTES ON MECHANICAL PLANS SHALL SUPERCEDE ANY GENERAL
NOTES ON THE PLANS.
II. EQUIPMENT
A. NEW DIFFUSERS:
1. DESIGNATION: NECK SIZE
CFM
B. RETURN AIR GRILLES:
1. 24X24 OR 24X12 FACE AS SHOWN.
2. COLOR: WHITE
C. NEW RIGID ROUND DUCTWORK:
1. MEDIUM PRESSURE: GALVANIZED STEEL SPIRAL WOUND DUCT.
2. LOW PRESSURE: GALVANIZED STEEL SNAP LOCK DUCT.
D. NEW RECTANGULAR DUCTWORK:
1. LOCATED IN CONDITIONED SPACE: ZINC COATED GALVANIZED STEEL WITH 1" ACOUSTIC LINER.
2. LOCATED IN UNCONDITIONED SPACE: ZINC COATED GALVANIZED STEEL WITH 1-1/2" ACOUSTIC LINER - MINIMUM R-6.
E. RIGID ROUND DUCTWORK INSULATION: FLEX MASTER THERMO SLEEVE TYPE TSM - MINIMUM R-12.
F. FLEXIBLE DUCTWORK:
1. LOW PRESSURE: FLEX MASTER TLM (ALUM. FLEX/METAL JACKET), UL181 - CLASS 1APPROVED, 8'0" MAXIMUM LENGTH.
2. MEDIUM PRESSURE: FLEX MATER TLM (ALUM. FLEX/NO INSUL.), UL181 - CLASS 1 APPROVED, 3'0" MAXIMUM LENGTH.
G. FIRE/SMOKE DAMPERS: COMBINATION FIRE/SMOKE DAMPERS SHALL BE FABRICATED IN ACCORDANCE WITH NFPA 90A AND
UL555S CLASS II. FIRE/SMOKE DAMPERS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S UL INSTALLATION
INSTRUCTIONS. ACTUATORS SHALL BE POWER OPEN/SPRING CLOSED OPERATION, 120 VOLT. THE FIRE FAIL/SAFE MODE SHALL
BE A UL 33 HEAT ACTUATED LINK FOR CLOSURE AND CONTAINMENT OF FIRE ZONE, INDEPENDENT OF ACTUATOR POSITIONING
OR SIGNALING. MANUFACTURED BY PREFCO, MODEL 5020 OR EQUAL.
H. HOT WATER HEATING PIPING/CHILLED WATER PIPING/CONDENSER WATER PIPING: ABOVEGROUND, NPS 2" AND SMALLER, SHALL
BE ANY OF THE FOLLOWING:
1. TYPE L, DRAWN-TEMPER, COPPER TUBING, WROUGHT-COPPER FITTINGS, AND SOLDERED JOINTS.
2. SCHEDULE 40, GRADE B, TYPE 96 STEEL PIPE; CLASS 150, MALLEABLE IRON FITTINGS, CAST-IRON FLANGES AND FLANGE
FITTINGS, AND THREADED JOINTS.
K. HYDRONIC PIPING INSULATION: MINERAL-FIBER, PREFORMED PIPE INSULATION: TYPE 1, 850° F. MINERAL OR GLASS FIBERS
BONDED WITH A THERMOSETTING RESIN. COMPLY WITH ASTMC 547, TYPE 1, GRADE A, WITH FACTORY APPLIED ASJ.
1. HEATING WATER 1-1/2" AND SMALLER = 1.5" THICK, HEATING WATER 2" AND LARGER = 2" THICK, CONDUCTIVITY = 0.27 @
125° F.
2. CHILLED WATER = 1.0 " THICK, CONDUCTIVITY = 0.25 @ 75° F.
III. EXECUTION
A. BALANCING:
1. CONTRACTOR SHALL ADJUST AND BALANCE VARIABLE VOLUME BOXES (VAV'S), FAN POWERED BOXES (FPB'S), AIR
CONDITIONING UNITS (AC'S), AND DIFFUSERS TO THE QUANTITIES SHOWN ON THE DRAWING. BALANCING WORK SHALL BE
PERFORMED IN ACCORDANCE WITH NEBB OR TABB STANDARDS BY A NEBB OR TABB CERTIFIED CONTRACTOR. SUBMIT
BALANCING REPORT TO THE ENGINEER.
2. EXISTING DIFFUSER DESIGNATION INDICATES CFM ONLY.
3. VAV BOX DESIGNATION INDICATES MAXIMUM CFM ADJUST MINIMUM TO 10% OF MAXIMUM.
4. WHERE LOW PRESSURE AIR HANDLING SYSTEMS CROSS INTO AN ADJACENT TENANT AREA, CONTRACTOR SHALL
BALANCE ALL DIFFUSERS ASSOCIATED WITH THE SYSTEM. DIFFUSERS NOT SHOWN OR SHOWN WITH NO CFM SHALL
MAINTAIN EXISTING CFM.
5. ADJUST WATER SYSTEMS, AFTER AIR BALANCING, TO PROVIDE DESIGN QUANTITIES.
6. ADJUST SYSTEMS TO PROVIDE SPECIFIED PRESSURE DROPS AND FLOWS THROUGH HEAT TRANSFER ELEMENTS PRIOR
TO THERMAL TESTING. PERFORM BALANCING BY MEASUREMENT OF TEMPERATURE DIFFERENTIAL IN CONJUNCTION WITH
AIR BALANCING.
B. CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADES AND NOTIFY 360 ENGINEERING, INC. IF ANY CONFLICTS OCCUR.
C. THERMOSTAT LOCATIONS AND HEIGHTS TO BE COORDINATED WITH BUILDING MANAGEMENT, VERIFIED BY THE ENGINEER.
CONTRACTOR TO CALIBRATE ALL THERMOSTATS SHOWN ON THIS PLAN. IT SHALL BE THE GENERAL CONTRACTOR'S
RESPONSIBILITY TO ENSURE THAT ALL EXISTING THERMOSTATS REMAIN INTACT DURING DEMOLITION. HEATING THERMOSTATS
MUST REMAIN OPERATIONAL AT ALL TIMES. IF REQUIRED FOR BETTER PROTECTION, THERMOSTATS MAY BE TEMPORARILY
MOUNTED IN THE CEILING PLENUM DURING DEMOLITION. THERMOSTATS SHALL BE MOUNTED AT A MAXIMUM 48" ABOVE
FINISHED FLOOR.
D. PROVIDE VOLUME DAMPERS AT ALL DIFFUSER TAKEOFFS.
E. ALL TAKEOFFS, RUNOUTS, AND FLEX DUCTWORK TO DIFFUSERS SHALL BE THE SAME SIZE AS DIFFUSER INLET UNLESS
OTHERWISE NOTED.
F. MECHANICAL CONTRACTOR TO CHECK OPERATION AND CONDITION OF ALL EXISTING MECHANICAL EQUIPMENT WITHIN THE
CONFINES OF THIS SPACE AND PREPARE A WRITTEN LIST OF ANY DEFICIENCIES IN EQUIPMENT OPERATION OR CONDITION. LIST
SHALL BE SUBMITTED TO OWNER TWO WEEKS AFTER THE AWARD OF THE CONTRACT.
G. THERMOSTAT CONTROL LINES SHALL BE SUPPORTED AT INTERVALS NOT TO EXCEED 4'0".
H. PROVIDE EXTERNAL INSULATION ON ALL NEW RIGID ROUND DUCTWORK.
I. PROVIDE ACCESS DOORS IN DUCTWORK AS REQUIRED FOR ACCESS TO FIRE DAMPERS, FIRE/SMOKE DAMPERS, OR ANY OTHER
MECHANICAL EQUIPMENT REQUIRING MAINTENANCE OF SERVICE.
J. ALL PIPE AND DUCT PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED PER 2015 IBC.
M
T
P
360Three Sixty Engineering, Inc.
1600 Jackson St. #360 Golden, CO 80401
303.940.2050 303.940.3322-fax
17-191A
DMD
Scale
Project Number
Date
Drawn by
Checked by
Anderson Hallas
Architects, PC
ARCHITECTURE
HISTORIC PRESERVATION
COPYRIGHT 2018
ANY UNAUTHORIZED USE OF THESE DOCUMENTS
IS PROHIBITED WITHOUT THE WRITTEN CONSENT
OF:
ANDERSON HALLAS ARCHITECTS, P.C.
PLANNING
Issue
715 FOURTEENTH STREET
GOLDEN, COLORADO 80401
(303) 278-4378
FAX (303) 278-0521
8/
1
4
/
2
0
1
9
1
0
:
4
4
:
1
7
A
M
M0.1
MECHANICAL
LEGEND AND
NOTES
2017910
PITKIN COUNTY
COURTHOUSE REMODEL
PITKIN COUNTY, CO
4/3/19
KPZ
MPC
506 E Main St St 300, Aspen, CO 81611
PERMIT
No. Description Date
4 BLDNG COMMENTS 2019.08.14
4
TO THE TOP OF THE THERMOSTAT.
08/21/2019
DN
DN
DN
S
S
S
S
S
AT
S
J
TC
TC
J
J
J
S
S
S
EF
1
FCU
1
EWH
4
EWH
1
L
1
WAP
S
S
S
S
S
S
S
S
S
PP
1
PP
4
WAP
WAP
WAP
WAP
WAP
WAP
WAP
JJJ
J
S
S
S
S
S
S
S
S
S
S
S
CR
CR
CR
CR
CR
CR
CR
CR
CR CR
CR
CR
J
CP
1
CUH
1
J
J
J J
J
J J
ELEV
1
(E)
(E) FACP
TTB
B
B1
ADA
UH
ADA
WP
JURY DELIBERATION
03
ATTORNEY
01
VEST.
03A
WOMEN
00C
MEN
00D
JUDGE RR
14
STORAGE
15
VISITING JUDGE'S
CHAMBERS
04
VISITING JUDGE'S
CHAMBERS
04
HALL
16
COURTROOM 3
05
HALL
00
STORAGE
00B
HALL
10
ELEV. MECH.
00E
CONF. RM
08
SECURE HALL
13
HALL
09
BOILER
01A
MECH/ELEC
02D
HOLDING
06
HALL
05A
?
?
AC
GFI
(E)
1
OFFICE 2
02B
OFFICE 1
02C
ATTORNEY
06A
MECH.
06B
ELEV.
11
ALPINE LEGAL
02E
BREAK ROOM
02A
VEST.
02
JURY RR
07
B1-9
DISHWASHER
B1-7
FRIDGE
B1-10
AC
GFI
B1-11
AC
GFI
B1-10
AC
GFI
AC
GFI
(E)
(E)
(E)
(E)
(E) (E)
(E)
(E)
(E)(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
+72"
(E)
(E)
(E)(E)(E)
(E)
(E)
+72"(E)
+72"
(E)
+42"
(E)
(E)
(E)
(E)
A
(E)
(E)
(E)
(E)(E)(E)
(E)
(E)
(E)
(E)
(E) (E)
AC
GFI
LOWER LIFT LOBBY
17
(E)
ZONE G.1
ZONE G.2
ZONE G.3
ZONE G.4
ZONE G.5
(RL)
(E)
2
2
2
2
2
+48"+48"
3
3
3 3
3
4
5
6
7 AV
RACK
88
8
5
MDP
UTILITY
METER
(E)
(E)
(E)
(E)
(E)
(E)
(E)
3
9
9 9
9
9
B1-20 B1-20
B1-20
B1-20
B1-20
B1-8
B1-8
B1-8
(E)
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(N)
10
NOT IN SCOPE
8
B1-20
(E)
+42"
(E)(E)
CLG
DOOR
POWER
11
12
DOOR
POWER
DOOR
POWER
ADA PUSHPLATE
ADA
PUSHPLATE
B1-21
CLG
B1-21
CLG
B1-21
13
D-43
CLG 14
D-43
CLG
14
D-43
CLG
14
D-43
CLG 14 D-43
CLG 14
(E)
(E)
WIREWAY
15
16
17
18
3/16" = 1'-0"1 GARDEN LEVEL ELECTRICAL PLAN
AE DESIGN
Integrated Lighting and Electrical Solutions
1900 Wazee Street #205 Denver, CO 80202 303.296.3034
aedesign-inc.com Project #: 3912.00
Project Number
Date
Drawn by
Checked by
Anderson Hallas
Architects, PC
ARCHITECTURE
HISTORIC PRESERVATION
COPYRIGHT 2018
ANY UNAUTHORIZED USE OF THESE DOCUMENTS
IS PROHIBITED WITHOUT THE WRITTEN CONSENT
OF:
ANDERSON HALLAS ARCHITECTS, P.C.
PLANNING
Issue
715 FOURTEENTH STREET
GOLDEN, COLORADO 80401
(303) 278-4378
FAX (303) 278-0521
Scale AS NOTED
8/
1
4
/
2
0
1
9
1
0
:
4
5
:
3
5
A
M
E1.0
GARDEN LEVEL
ELECTRICAL PLAN
2017910
PITKIN COUNTY
COURTHOUSE REMODEL
PITKIN COUNTY, CO
4/03/19
BYF
KMD
506 E Main St St 300, Aspen, CO 81611
PERMIT
No. Description Date
1 Addendum #2 05-23-2019
4 BLDG COMMENTS 2019.08.14
GENERAL NOTES
A
B
C
D
E
F
G
HATCHED AREA REPRESENTS AREA WITH NO ELECTRICAL SCOPE.
UNLESS OTHERWISE INDICATED, CONNECT NEW DEVICES TO EXISTING
NEARBY CIRCUITRY MAINTAINED DURING DEMOLITION. EXTEND CONDUIT
AND FEEDERS AS NECESSARY. CONTRACTOR TO VERIFY ANY CIRCUITS
MODIFIED ENTIRELY OR IN PART SHALL NOT EXCEED 1920VA AND (8)
RECEPTACLES MAXIMUM PER CIRCUIT.
REFER TO MECHANICAL EQUIPMENT PLANS FOR ADDITIONAL CIRCUIT
INFORMATION.
COORDINATE ALL SECURITY ITEM LOCATION AND REQUIREMENTS WITH
SECURITY VENDOR PRIOR TO COMMENCEMENT OF WORK. PROVIDE
JUNCTION BOXES AND CONDUIT AS NECESSARY PER VENDOR
REQUIREMENTS.
COORDINATE ALL LOW VOLTAGE AND IT ITEM LOCATION AND
REQUIREMENTS WITH LOW VOLTAGE VENDOR PRIOR TO COMMENCEMENT
OF WORK. PROVIDE JUNCTION BOXES AND CONDUIT AS NECESSARY PER
VENDOR REQUIREMENTS.
AS GARDEN LEVEL CEILINGS ARE BEING REPLACED, ROUTE GARDEN LEVEL
CONDUITS ABOVE GARDEN LEVEL CEILING, ROUTE MAIN LEVEL CONDUITS
DOWN THROUGH GARDEN LEVEL CEILING. CONDUITS ON SECOND FLOOR
SHALL BE ROUTED ABOVE SECOND FLOOR CEILING.
ALL CONDUITS SHALL BE HIDDEN IN WALLS OR CEILINGS AS MUCH AS
POSSIBLE. COORDINATE WITH ARCHITECT IN ALL LOCATIONS WHERE
CONDUIT MUST BE SURFACE MOUNT, INCLUDING EXTERIOR OF BUILDING.
KEYNOTE LEGEND
KEY
VALUE KEYNOTE TEXT
1 EXISTING CONDITION REPRESENTATIVE OF A RECEPTACLE PLUG MOLD.
DEVICES INTEGRATED INTO MOLD ARE SHOWN ATTACHED. NO NEW WORK.
2 ZONE INDICATED FOR LOAD JUSTIFICATION PURPOSES. ALL DEVICES IN
ZONE SHALL BE RECIRCUITED TO EXISTING NEARBY CIRCUIT MAINTAINED
DURING DEMOLITION UNLESS OTHERWISE NOTED. EXTEND CIRCUITRY TO
NEW DEVICES AS NECESSARY. REFER TO GENERAL NOTES FOR
ADDITIONAL INFORMATION.
3 PROVIDE RECESSED FLOORBOX, HUBBELL SYSTEM-ONE 2-GANG
RECESSED FLOORBOX WITH CORROSION RESISTANCE OR SIMILAR. BOX
SHALL HAVE A MINIMUM OF (2) DUPLEX RECEPTACLES.
4 PROVIDE 2-GANG JUNCTION BOX WITH 3/4" CONDUIT TO AV EQUIPMENT
RACK. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH AV
VENDOR PRIOR TO INSTALLATION.
5 PROVIDE 4-GANG JUNCTION BOX WITH (2) 3/4" CONDUIT TO AV EQUIPMENT
RACK. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH AV
VENDOR PRIOR TO INSTALLATION.
6 PROVIDE 1-GANG JUNCTION BOX WITH 3/4" CONDUIT TO AV EQUIPMENT
RACK. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH AV
VENDOR PRIOR TO INSTALLATION.
7 LOCATION OF AV EQUIPMENT RACK. PROVIDE 3/4" CONDUIT TO ALL CEILING
SPEAKERS AND ASSISTED LISTENING PANEL. COORDINATE EXACT
LOCATION AND REQUIREMENTS WITH AV VENDOR PRIOR TO INSTALLATION.
8 PROVIDE RECESSED FLOORBOX, HUBBELL SYSTEM-ONE 4-GANG
RECESSED FLOORBOX WITH CORROSION RESISTANCE OR SIMILAR. BOX
SHALL HAVE A MINIMUM OF 2-GANG AV SPACE WITH (2) 1" CONDUIT ROUTED
UNDERFLOOR TO AV RACK LOCATION. COORDINATE EXACT LOCATION
WITH AV VENDOR PRIOR TO INSTALLATION.
9 FLOOR RECEPTACLES INDICATED SHALL BE CIRCUITED TOGETHER ON
EXISTING CIRCUIT MADE SPARE THROUGH DEMOLITION.
10 CONTRACTOR SHALL REMOVE TEMPORARY POWER PANEL LOCATED
APPROXIMATELY 50' NORTH OF COURTHOUSE AND NEAR PITKIN COUNTY
JAIL BUILDING TRANSFORMER. COORDINATE WITH OWNER AS NECESSARY.
11 CONNECT NEW POWERED DOOR TO EXISTING CIRCUIT INDICATED.
COORDINATE WITH DOOR VENDOR FOR EXACT REQUIREMENTS.
12 NEW EXTERIOR CARD READER AND PANIC HARDWARE WILL BE INSTALLED
AT FENCE GATE NEAR PITKIN COUNTY JAIL APPROXIMATELY 43' NORTH OF
BUILDING. PROVIDE CONDUIT AND BACKBOX AND COORDINATE WITH
SECURITY VENDOR FOR EXACT REQUIREMENTS. REFER TO SHEET A0.1
FOR ADDITIONAL INFORMATION.
13 CONNECT AUTODOOR TO CIRCUIT INDICATED. PROVIDE CONDUIT AND
BACKBOX TO ADA PUSHPLATES AND COORDINATE WITH SECURITY AND
FIRE ALARM VENDOR FOR SECURITY AND EGRESS PURPOSES AS
NECESSARY.
14 PROVIDE 120V POWER FOR FIRE/SMOKE DAMPERS. COORDINATE EXACT
QUANTITIES, LOCATIONS, AND REQUIREMENTS WITH MECHANICAL
CONTRACTOR. ALSO, COORDINATE WITH FIRE ALARM VENDOR AS
NECESSARY. REFER TO DETAIL #1 ON SHEET E7.00 FOR ADDITIONAL
INFORMATION.
15 NEW ELEVATOR EQUIPMENT. CONNECT TO EXISTING CIRCUITRY
MAINTAINED DURING DEMOLITION, OR NEW CIRCUITRY IF CONTRACTOR
DETERMINES EXISTING FEEDERS DO NOT MATCH NEW INDICATED IN
EQUIPMENT SCHEDULE. ALSO CONNECT TO EXISTING FIRE ALARM
SYSTEM/CIRCUITRY MAINTAINED DURING DEMOLITION AS REQUIRED.
16 CONNECT NEW ELEVATOR EQUIPMENT TO EXISTING ELEVATOR FUSED
DISCONNECT PER NEC 620.51(A), NOTIFY ENGINEER IF EXISTING
DISCONNECT DOES NOT CONTAIN 150A FUSES.
17 PROVIDE NEW LOCKABLE SPST FUSED DISCONNECT FOR ELEVATOR CAB
LIGHT PER NEC 620.22(A) AND CONNECT TO EXISTING CIRCUITRY
MAINTAINED DURING DEMOLITION. FUSE SHALL BE 20A FRS-R AND
DISCONNECT SHALL BE 30A1P. EC SHALL VERIFY CIRCUIT TO DISCONNECT
IS DEDICATED PER THE REQUIREMENTS OF NEC 620.22(A).
18 PROVIDE DEDICATED TELEPHONE LINE TO ELEVATOR MACHINE ROOM PER
ELEVATOR VENDOR REQUIREMENTS.
4
8/14/19
08/21/2019
SS
S
S
S
S
S
S
WAP
S
S
S
S
S
S
S
S
S
AT
S
J
J
J
J
TC
TC
J
J
J
(E)
(R) (R)
(R)
+42"
(R)
AC
GFI
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(ER)(R)
(R)
(R)
(R)
(R)
(R)(R)
AC
(R)
AC
GFI (R) (R) (R) (R)(R) (R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R) (R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)(R)(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R) (R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)(R)
(R)
(R)
+42"
(R)
(E)
+42"
(R)
(R)(R)(R)
(R)
+48"
(R)(R) (R) (R)
(R)(R)(R)
(R)
(R)
(R)
(R)
(E)
(E) (E)
(E)(R)
(E)
(E)
(E)
(R)
(R)
(R)(E)(E)(E)(R)(R)
(R)
(R)
(R)
(E)
(E)
(E)
(R)
CLG
(R)
(R)(R)
(E)
+72"
(R) (R)
(E)
(E)
+72"
(R)(E)(E)
(E)
(E)
(E)
(E)
(E)
(E)(E)
(E)
(E)
(R)(R)(R)
(R)
(R)
(R)
(R)
(E)
(E)
(E)
+42"
(E)
+72"
(E)
(R)
ZONE G.1
ZONE G.2
ZONE G.3
ZONE G.4
ZONE G.5 1
1
1
1
1
2
(R)
(R)
(R)
(E)
(E)(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
WIREWAY
ELEV
(R)
(R)
3
4
5
Project Number
Date
Drawn by
Checked by
Anderson Hallas
Architects, PC
ARCHITECTURE
HISTORIC PRESERVATION
COPYRIGHT 2018
ANY UNAUTHORIZED USE OF THESE DOCUMENTS
IS PROHIBITED WITHOUT THE WRITTEN CONSENT
OF:
ANDERSON HALLAS ARCHITECTS, P.C.
PLANNING
Issue
715 FOURTEENTH STREET
GOLDEN, COLORADO 80401
(303) 278-4378
FAX (303) 278-0521
Scale AS NOTED
8/
1
4
/
2
0
1
9
1
0
:
4
5
:
3
8
A
M
ED1.0
GARDEN LEVEL
ELECTRICAL PLAN
DEMO
2017910
PITKIN COUNTY
COURTHOUSE REMODEL
PITKIN COUNTY, CO
4/03/19
BYF
KMD
506 E Main St St 300, Aspen, CO 81611
PERMIT
No. Description Date
1 Addendum #2 05-23-2019
4 BLDG COMMENTS 2019.08.14
3/16" = 1'-0"1 GARDEN LEVEL ELECTRICAL PLAN DEMO
KEYNOTE LEGEND
KEY
VALUE KEYNOTE TEXT
1 ZONE INDICATED FOR LOAD JUSTIFICATION PURPOSES. ALL DEVICES
INDICATED TO BE REMOVED IN ZONE SHALL BE DEMOLISHED WITH
CIRCUITRY MAINTAINED FOR REUSE/EXTENSION TO NEW WORK. REFER TO
GENERAL NOTES AND NEW PLANS FOR ADDITIONAL INFORMATION.
2 EXISTING OVERHEAD SOFFIT IN THIS SPACE TO BE DEMOLISHED (BY
OTHERS). SOFFIT CONTAINS (4) EXISTING ELECTRICAL CONDUITS WHICH
MUST BE RELOCATED. EXISTING ROUTING AND TERMINATION POINTS OF
CONDUIT IS CURRENTLY UNKNOWN, EC SHALL TRACE CONDUIT IN FIELD,
REMOVE IF NOT IN-USE OR RELOCATE AS NEEDED. ANTICIPATE
INTERCEPTING CONDUITS IN THE VISITING JUDGE'S CHAMBERS AND
RE-ROUTING AROUND THE LOWER LIFT LOBBY BACK INTO COURTROOM 3.
3 EXISTING ELEVATOR EQUIPMENT TO BE REPLACED WITH NEW IN SAME
LOCATION. NEW ELEVATOR ELECTRICAL CHARACTERISTICS (3OHP) ARE
SAME AS EXISTING (30HP). CONTRACTOR SHALL MAINTAIN EXISTING FIRE
ALARM CONNECTIONS AND EXISTING POWER CIRCUITRY IF VERIFIED TO
MATCH NEW. REFER TO ELEVATOR EQUIPMENT INFORMATION IN
MECHANICAL SCHEDULE FOR MORE INFORMATION.
4 EXISTING CAB LIGHT DISCONNECT IS A TOGGLE SWITCH AND SHALL BE
REPLACED WITH FUSED DISCONNECT. REMOVE EXISTING TOGGLE SWITCH
AND MAINTAIN EXISTING CIRCUITRY FOR CONNECTION TO NEW
DISCONNECT SWITCH IN NEW WORK. EC SHALL VERIFY CIRCUIT TO
DISCONNECT IS DEDICATED PER THE REQUIREMENTS OF NEC 620.22(A).
5 CONTRACTOR SHALL MAINTAIN EXISTING FUSED DISCONNECT IF VERIFIED
TO BE A 150A FUSE IN 200A3P DISCONNECT. OTHERWISE REPLACE WITH
NEW IN SAME LOCATION. VERIFY FEED TO DISCONNECT MATCHES NEW
FEEDER PER EQUIPMENT INDICATED IN MECHANICAL EQUIPMENT
SCHEDULE.
AE DESIGN
Integrated Lighting and Electrical Solutions
1900 Wazee Street #205 Denver, CO 80202 303.296.3034
aedesign-inc.com Project #: 3912.00
GENERAL NOTES
A
B
C
D
HATCHED AREA REPRESENTS AREA WITH NO ELECTRICAL SCOPE.
ALL EQUIPMENT AND DEVICES SHOWN IN DARK LINE WEIGHT SHALL BE
DEMOLISHED. MAINTAIN EXISTING CIRCUITRY FOR REUSE IN NEW WORK.
CONTRACTOR TO VERIFY ANY CIRCUITS MODIFIED ENTIRELY OR IN PART
SHALL NOT EXCEED 1920VA AND (8) RECEPTACLES MAXIMUM PER CIRCUIT.
CONTRACTOR TO VERIFY WITH SECURITY VENDOR AND LOW VOLTAGE
VENDOR ANY WORK PRIOR TO DEMOLITION OF SECURITY OR LOW VOLTAGE
DEVICES OR EQUIPMENT.
4
8/14/19
08/21/2019