HomeMy WebLinkAboutFile Documents.232 E Main St.0078-2020-BCHO (71)www.kengsc.com Project number Date Drawn by Checked by SEAL: COPYRIGHT 2018 K.ENG LLC SHEET NUMBER: TITLE: FIRM ILLINOIS LICENSE NO. 184-004153 KDK KDK S1.0 GENERAL NOTES 18-1015 232 E MAIN ST. ASPEN, CO CORE AND SHELL BUILDING 6-14-2018 DESIGN CRITERIA BUILDING CODE: 2015 INTERNATIONAL BUILDING CODE ASCE 7-10 DESIGN CODES: AISC (ASD) 360-10, ACI 318-11, ACI 530-11, AISI S100, NDS 2015 LOADS: ROOF LIVE LOAD = 20 PSF (MIN.) ROOF SUPERIMPOSED DEAD LOAD = 30PSF AT ROOF DECK AREA ROOF DECK LIVE LOAD = 100PSF SECOND FLOOR LIVE LOAD = 50PSF OFFICE + 15PSF PARTITIONS STAIRS = 100PSF LIVE LOAD RAILINGS = 50PLF UNIFORM AND 200LB CONCENTRATED (LOCATED ANYWHERE) NON-CONCURRENT WIND:Vult = 115 MPH, EXPOSURE B, RISK CATEGORY II I = 1.0, GCpi =+/-0.18 SEE S1.2 AND S1.3 FOR COMPONENT AND CLADDING WIND PRESSURES SNOW:Pg = 100 PSF, SEE S1.2 AND S1.3 FOR SNOW LOADS, Ce = 1.0, I = 1.0, Ct = 1.0 TYPICAL, Ct = 1.2 @ AWNINGS SEISMIC: I = 1.0, Ss = 31.4%, S1 = 8.2%, SITE CLASS C, SDS = 0.251, SD1 = 0.093, DESIGN CATEGORY B ORDINARY MASONRY SHEAR WALLS AND CLT SHEAR WALLS AT G LINE DESIGN BASE SHEAR = 58.1K SEISMIC RESPONSE COEFFICIENT, Cs = 0.1256 RESPONSE MODIFICATION COEFFICIENT R = 2 EQUIVALENT FORCE PROCEDURE GENERAL NOTES 1. ALL SECTIONS, DETAILS, AND NOTES ARE INTENDED TO BE TYPICAL AND SHALL APPLY TO SIMILAR SITUATIONS. 2. ALL DIMENSIONS AND SIZES OF EXISTING CONSTRUCTION INDICATED ON DRAWINGS SHALL BE CONSIDERED APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR. EXISTING DIMENSIONS SHALL BE DOCUMENTED IN WRITING AND PROVIDED TO THE ENGINEER FOR RECORD. 3. CONTRADICTIONS BETWEEN ACTUAL FIELD CONDITIONS AND CONDITIONS SHOWN SHALL BE REPORTED TO THE ENGINEER AND IF NECESSARY FURTHER DETAILS WILL BE PROVIDED. 4. IF THE CONTRACTOR ENCOUNTERS PROBLEMS IN PERFORMANCE OF THE WORK INDICATED, HE SHALL BRING SUCH PROBLEMS TO THE ATTENTION OF ENGINEER FOR THE PROPER ACTION BEFORE WORK CONTINUES. THE CONTRACTOR SHALL NOTIFY THE A/E OF ANY ITEMS NOT SHOWN OR INDICATED IN THE CONSTRUCTION DOCUMENTS THAT, IN HIS OPINION, REQUIRE REPAIR OR MODIFICATION. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND CONSTRUCTION OF ALL SHORING, BRACING AND FALSEWORK REQUIRED FOR THE RENOVATION AND CONSTRUCTION WORK. THE CONTRACTOR SHALL SUBMIT FOR ARCHITECT'S REVIEW A LAYOUT OF SHORING INDICATING PLACEMENT AND LOAD CAPACITIES OF SHORING ELEMENTS. 6. DURING CONSTRUCTION ALL MATERIALS SHALL BE CAREFULLY HANDLED TO PROTECT ALL EXISTING FACILITIES. 7. DO NOT CUT, CORE, OR HAMMER THRU OR INTO ANY EXISTING FRAMING UNLESS SPECIFICALLY NOTED ON THE STRUCTURAL DRAWINGS OR NOTED IN WRITING FROM THE ENGINEER. 8. VERIFY LOCATION OF ALL OPENINGS, EMBEDDED ITEMS AND CONCRETE CONFIGURATIONS WITH DRAWINGS AND SPECIFICATIONS FROM ALL OTHER DISCIPLINES. LOCATE AND SHOW ALL THESE ITEMS ON APPROVED SHOP DRAWINGS. 9. IT IS NOT TO BE IMPLIED IN ANY WAY WHATSOEVER THAT THE ENGINEER OR ARCHITECT IS RESPONSIBLE FOR THE METHODS AND MEANS OF ANY ASPECT OF THIS PROJECT. 10. EXISTING PIPES, ELECTRICAL BOXES, DUCTWORK, FAN UNITS, GARAGE DOOR TRACKS AND MOTORS, HANDRAIL ETC. TO BE RELOCATED AND MODIFIED AS NECESSARY TO ACCOMMODATE COLUMN, BEAM OR SLAB MODIFICATIONS/ADDITIONS. 11. THE CONTRACTOR AND SUBCONTRACTOR ASSUME FULL LIABILITY FOR THE STRUCTURAL INTEGRITY OF THE INDICATED STRUCTURAL ROOF AND/OR FLOOR SYSTEMS WHEN SHOP DRAWINGS ARE NOT SUBMITTED OR FOLLOWED. 12. DO NOT SCALE THESE DRAWINGS. USE DIMENSIONS. 13. IN CASES WHICH MATERIAL SHOWN OR SPECIFIED IS NOT READILY AVAILABLE, THE CONTRACTOR MAY PROPOSE THE USE OF AN ALTERNATE SUBJECT TO THE REVIEW OF THE ENGINEER. THE ALTERNATE MUST PROVIDE THE SAME STRENGTH, STIFFNESS, AND DURABILITY OF THE ORINGINAL DESIGN. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THAT THE ALTERNATES TO NOT INTERFERE WITH ANY ARCHITECTURAL, STRUCTURAL, ELECTRICAL, OR MECHANICAL REQUIREMENTS, ETC. 15. THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION. THE CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY BRACING THAT MAY BE REQUIRED AS THE RESULT OF THE CONTRACTOR'S MEANS AND METHODS AND/OR SEQUENCES. 16. THE CONTRACTOR'S CONSTRUCTION AND/OR ERECTION SEQUENCES SHALL RECOGNIZE AND CONSIDER THE EFFECTS OF THERMAL MOVEMENTS OF STRUCTURAL ELEMENTS DURING THE CONSTRUCTION PERIOD. 17. THE CONTRACTOR IS RESPONSIBLE FOR LIMITING THE AMOUNT OF CONSTRUCTION LOADS IMPOSED ON THE STRUCTURAL FRAMING. CONSTRUCTION LOADS SHOULD NOT EXCEED THE DESIGN CAPACITY OF THE FRAMING AT THE TIME THE CONSTRUCTION LOADS ARE IMPOSED. FOUNDATIONS 1. SPREAD FOOTINGS SHALL BEAR ON UNDISTURBED SOIL OR ENGINEERED FILL CAPABLE OF SUSTAINING A NET ALLOWABLE BEARING PRESSURE OF 4000 PSF UNDER INDIVIDUAL AND CONTINUOUS FOOTINGS UNDER FULL SERVICE DEAD AND LIVE LOADS. REFER TO GEOTECHNICAL REPORT BY CTL THOMPSON INC. PROJECT NO. GS06130.000-125 DATED MAY 19, 2017 2. ANY UNSUITABLE SOIL SHALL BE REMOVED AND REPLACED BY CLEAN GRANULAR FILL MATERIAL COMPACTED TO A MINIMUM OF 95% OF "ASTM" D-1557-78 MODIFIED PROCTOR DENSITY OR BY A LEAN CONCRETE MIX AS APPROVED BY GEOTECHNICAL ENGINEER. BUILDING SITE TO BE UNDERCUT AS NEEDED AND UNDER DIRECTION OF GEOTECH TO REMOVE UNSUITABLE FILL AND BACKFILLED WITH ENGINEERED FILL TO BOTTOM OF FOOTING ELEVATIONS AS SHOWN. THERE IS POTENTIAL NEEDED TO UNDERPIN THE ADJACENT PROPERTY TO THE WEST. REFER TO GEOTECHNICAL REPORT REGARDING SITE PREPARATION. 3. BOTTOM OF ALL EXTERIOR FOOTINGS SHALL BEAR A MINIMUM OF 3' -0" BELOW GRADE FOR FROST PROTECTION. 4. BACKFILL AGAINST WALLS AND GRADE BEAMS EVENLY ON BOTH SIDES. RETAINING WALLS SHALL BE BRACED AGAINST BACKFILLING PRESSURES UNTIL THE FLOOR SLAB (AND POSSIBLY THE FIRST FLOOR FRAMING) IS IN PLACE. 5. A VAPOR BARRIER SHALL BE PROVIDED UNDER ALL INTERIOR SLABS-ON-GRADE PER THE SPECIFICATIONS. 6. NO FOUNDATIONS SHALL BE PLACED ONTO OR AGAINST SUBGRADES THAT ARE FROZEN OR CONTAINING FREE WATER, FROST, OR ICE STRUCTURAL STEEL 1. ALL STEEL SHALL CONFORM TO THE FOLLOWING: ALL WIDE FLANGE BEAMS = ASTM A992 HSS RECT SHAPES = ASTM A500 GRADE B MISC. PLATES, CHANNELS, ANGLES, ETC. = ASTM A36 ANCHOR RODS = ASTM F1554 GRADE 36 BOLTS (TYPICAL) = ASTM A325N, U.N.O. WELDING ELECTRODES = E70XX 2. ALL STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED, AND ERECTED IN ACCORDANCE WITH THE AISC CODE OF STANDARD PRACTICE (2016), EXCEPT AS MODIFIED IN THESE NOTES. 3. THE SPLICING OF STEEL MEMBERS IS PROHIBITED. 4. ALL FILLET WELDS SHALL BE A MINIMUM OF 1/4". 5. GROUT UNDER BASE PLATES AND BEAM BEARING PLATES SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH OF 5000 PSI. 6. STEEL FABRICATOR TO SUBMIT SIGNED AND SEALED CONNECTION CALCULATIONS BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF COLORADO. CONNNECTIONS SHALL BE DESIGNED AS AISC SIMPLE SHEAR CONNECTIONS CAPABLE OF SUPPORTING THE REACTION INDICATED OR CAPABLE OF SUPPORTING 50% OF THE TOTAL ALLOWABLE UNIFORM LOAD FOR A GIVEN SIZE, SPAN, AND GRADE OF BEAM AS TABULATED IN THE AISC TABLES FOR ALLOWABLE LOADS. BEAM MOMENT PROVIDED ON PLANS WHEN REQUIRED AS PART OF CONNECTION. CONNECTION CALCULATIONS TO BE REVIEWED BY ENGINEER OF RECORD FOR COMPLIANCE. MASONRY (STRUCTURAL) 1. REINFORCED MASONRY SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH, f'm, OF 2000 PSI. MASONRY UNITS SHALL BE NORMAL WEIGHT CONCRETE BLOCK CONFORMING TO ASTM C90, GRADE N, TYPE 1 WITH A MINIMUM NET AREA COMPRESSIVE STRENGTH OF 2800 PSI. MORTAR SHALL CONFORM TO ASTM C270, TYPE S. GROUT SHALL CONFORM TO ASTM C476 AND SHALL HAVE A MINIMUM STRENGTH OF 2000 PSI. IN NO INSTANCE SHALL MORTAR BE USED AS A SUBSTITUTE FOR GROUT. ALL REINFORCING, WHETHER VERTICAL OR HORIZONTAL, SHALL BE EMBEDDED IN GROUTED CELLS. 2. REINFORCING BARS SHALL CONFORM TO ASTM A615, INCLUDING SUPPLEMENTAL REQUIREMENTS S1, GRADE 60 UNLESS NOTED OTHERWISE. 3. JOINT REINFORCING SHALL BE GALVANIZED FABRICATED UNITS (LADDER TIES) WITH A SINGLE PAIR OF 9 GAGE SIDE RODS AND 9 GAGE CROSS RODS FABRICATED FROM COLD DRAWN STEEL WIRE COMPLYING WITH ASTM A82. JOINT REINFORCING SHALL BE SPACED AT 16"O.C. VERTICALLY IN ALL MASONRY WALLS. 4. GROUT CELLS SOLID AT VERTICAL AND HORIZONTAL WALL REINFORCING. GROUT ALL CELLS BELOW GRADE SOLID. 5. REINFORCING THAT IS TO BE SPLICED SHALL BE LAPPED A MINIMUM OF 30" FOR #5 REBAR AND SMALLER AND 42" FOR #6 AND #7 REBARS. 6. SECURE ALL REINFORCING IN PLACE AT 48" O.C. MAXIMUM PRIOR TO GROUTING. 7. SEE ARCHITECTURAL ELEVATIONS AND PLANS FOR LOCATIONS OF VERTICAL CONTROL JOINTS. SPACE VERTICAL CONTROL JOINTS AT 32'-0" OR LESS. HORIZONTAL BOND BEAM OR MASONRY BEAM REINFORCEMENT SHALL BE CONTINUNOUS ACROSS THE JOINT. JOINT REINFORCING SHALL STOP ON EACH SIDE OF THE CONTROL JOINT. 8. FOUNDATION DOWELS SHALL NOT BE BENT MORE THAN 1 IN 6 (HORIZ. TO VERT.) TO ALIGN WITH MASONRY CELLS. 9. VERTICAL REINFORCING SHALL HAVE A MINIMUM CLEARANCE OF 3/4" OR ONE BAR DIAMETER WHICHEVER IS GREATER TO A MASONRY FACE. REINFORCING, HORIZ. OR VERT., SHALL BE SPACED AT LEAST ONE BAR DIAMETER APART. 10. VERTICAL CELLS TO BE GROUTED NEED TO HAVE AN UNOBSTRUCTED CELL AREA OF NOT LESS THAN 3"x4". 11. VERTICAL GROUTED SHALL BE DONE IN FOUR FEET LIFTS WITH GROUTING STOPPING 1 1/2" BELOW THE TOP OF THE MASONRY BLOCK AS TO FORM A KEY. 12. MASONRY BOND BEAM LINTELS SHALL BE GROUTED SOLID IN ONE CONTINUOUS OPERATION. 13. ALL BOLTS, RODS, ANCHORS, ETC. SHALL BE GROUTED SOLID IN POSITION OR BE EXPASION BOLTED INTO GROUTED SOLID CELLS. CONCRETE 1. ALL FOUNDATION AND SLAB -ON-GRADE CONCRETE SHALL BE NORMAL WEIGHT CONCRETE WITH A 28 DAY COMPRESSIVE STRENGTH OF 4000 PSI. CONCRETE TOPPING AT THE SECOND FLOOR SHALL BE LIGHTWEIGHT (110PCF) CONCRETE WITH A 28 DAY COMPRESSIVE STRENGTH OF 3000 PSI. THE WATER CEMENT RATIO SHALL BE 0.4 MAX. CONCRETE MIXES SHALL HAVE A MAXIMUM SLUMP OF 4" WITHOUT A WATER REDUCING ADMIXTURE AND 10" WITH A WATER REDUCING ADMIXTURE. 2. ALL EXPOSED CONCRETE SHALL HAVE AN APPROVED AIR ENTRAINING ADMIXTURE. PROVIDE 6% TO 8% AIR ENTRAINMENT. 3. ALL REINFORCING SHALL BE DETAILED AND FABRICATED IN ACCORDANCE WITH ACI 318-11. CONCRETE HAS BEEN DESIGNED IN ACCORDANCE WITH ACI 318-11. 4. REINFORCING STEEL: ASTM A615 GRADE 60, UNCOATED. 5. CONCRETE COVER FOR REINFORCEMENT: UNFORMED SURFACE IN CONTACT WITH THE GROUND = 3" FORMED SURFACES EXPOSED TO EARTH OR WEATHER = 1 1/2" (#5 BARS OR SMALLER) =2" ( #6 BARS AND LARGER) FORMED SURFACES NOT EXPOSED TO EARTH OR WEATHER: SLABS, WALLS, JOISTS = 3/4" (#11 BARS AND SMALLER) BEAMS, COLUMNS = 1 1/2" (TO PRIMARY REINF., TIES, OR STIRRUPS) 6. NO CHLORIDES ALLOWED IN THE CONCRETE MIX. 7. ALL SLABS-ON-GRADE SHALL BE PLACED ON COMPACTED GRANULAR FILL. PITCH SLABS TO DRAINS. 8. FIELD BENDING OF REINFORCING SHALL BE DONE COLD. 9. NO ALUMINUM OF ANY TYPE SHALL BE ALLOWED IN THE CONCRETE WORK. 10. ALL READY-MIXED CONCRETE WILL COMPLY WITH ASTM C94. 11. BASE PLATES, ANCHOR RODS, BELOW GRADE SHALL BE COVERED WITH A MINIMUM OF 3" OF CONCRETE. SHOP DRAWING SUBMITTALS 1. SHOP DRAWINGS FOR STRUCTUAL ITEMS (WOOD JOISTS, STRUCTURAL STEEL, MISCELLANEOUS STEEL, CONCRETE REINFORCEMENT) ARE TO BE SUBMITTED TO THE ENGINEER FOR REVIEW. NO WORK ON ITEMS SHOWN THEREON IS TO PROCEED UNLESS THE REVIEW STAMP CLEARLY INDICATES "REVIEWED" OR "REVIEWED WITH COMMENTS." CONTRACTOR ASSUMES ALL RISKS WHEN PROCEEDING WITHOUT APPROVED SHOP DRAWINGS INCLUDING CORRECTIVE ACTION SUCH AS ENGINEERING REDESIGN, FIELD REPAIRS, OR REMOVAL AND REPLACEMENT OF DEFICIENT ITEMS. 2. THE CONTRACTOR SHALL PRECHECK ALL THE SHOP DRAWING SUBMITTALS PRIOR TO THE SUBMISSION TO THE ENGINEER AND/OR ARCHITECT FOR REVIEW. ALL SUBMITTALS SHALL BEAR THE REVIEW STAMP OF THE CONTRACTOR. 3. THE USE OF REPRODUCTIONS OF THESE CONTRACT DRAWINGS BY ANY CONTRACTOR, SUB CONTRACTOR, ERECTOR, FABRICATOR, DETAILER, OR MATERIAL SUPPLIER IN LIEU OF PREPARED SHOP DRAWINGS SIGNIFIES THE CONTRACTOR'S ACCEPTANCE OF ALL OF THE INFORMATION SHOWN HEREIN AS CORRECT AND OBLIGATES HIMSELF TO ANY JOB EXPENSE, REAL OR IMPLIED, ARISING DUE TO ANY ERRORS THAT MAY HAVE OCCURRED HEREON. SUCH USE OF THESE CONTRACT DOCUMENTS WILL NOT BE ALLOWED WITHOUT PRIOR CONSENT OF THE ENGINEER. 4, THE ENGINEER DOES NOT APPROVE THE DESIGN OF CONCRETE MIXES. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE PERFORMANCE OF THE CONCRETE SUPPLIED TO THE JOB. PROPOSED MIX DESIGNS SHALL BE SUBMIITTED TO THE ENGINEER FOR RECORD AND SHALL BE REVIEWED AND APPROVED FOR CONFORMANCE TO THE REQUIREMENTS OF THE CONTRACT DOCUMENTS BY AN INDEPENDANT TESTING AGENCY. 5. AWNING FRAMING DESIGNED BY OTHERS FOR SNOW AND WIND LOADS AS INDICATED ON S1.2. AWNING SHOP DRAWINGS ALONG WITH STRUCTURAL CALCULATIONS SIGNED BY COLORADO PE SHALL BE SUBMITTED FOR REVIEW FOR COMPLIANCE BY EOR. NOTE REFER TO SHEET S1.1 FOR SPECIAL INSPECTIONS REQUIRED TIMBER FRAMING 1. ALL FRAMING FOR FLOORS AND ROOF CONSIST OF TIMBER BEAMS AND COLUMNS AND CLT FLOOR AND WALL PANELS AS DESIGNED AND DETAILED BY WESTERN WOOD STRUCTURES, INC. REFER TO STAMPED AND SIGNED DRAWINGS BY WESTERN WOOD FOR ALL INFORMATION NOT SHOWN IN THESE PLANS. EXP 10-31-21 No.Description Date 1 PERMIT 9-25-2018 2 ISSUE FOR BID 11-28-2018 4 PERMIT CORRECTION 12-18-2019 5 CONSTRUCTION 5-27-2020 14 WESTERN WOOD COORD.9-18-2020 ACI 318-14 ACI 318-14 UNIFORM ROOF SNOW LOAD = 70 PSF 12/02/2020 SPECIAL INSPECTION SCHEDULE PER 2015 IBC CHAPTER 17 ITEMS `CONTINUIOUS PERIODIC INSPECTION INSPECTION SOILS 1705.6 1. VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY. 2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL. 3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS. 4. VERIFY USE OF PROPER MATERIALS, DENSITIES, AND LIFT THICKNESSES DURING PLACEMENT AND COMPACTION OF COMPACTED FILL. 5. PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE SUBGRADE AND VERIFY THAT SITE HAS BEEN PREPARED PROPERLY. X X X X X CONCRETE 1705.3 1. INSPECTION OF REINFORCING STEEL. 2. INSPECTION OF ANCHORS CAST IN AND POST-INSTALLED IN HARDENED CONCRETE MEMBERS. 3. VERIFY USE OF REQUIRED DESIGN MIX. 4. AT THE TIME OF FRESH CONCRETE IS SAMPLED TO FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND AIRE CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF THE CONCRETE. 5. INSPECTION OF CONCRETE PLACMENT FOR PROPER APPLICATION TECHNIQUES. 6. INSPECTION FOR MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES. 7. INSPECT FORMWORK FOR SHAPE, LOCATION, AND DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED. X X X X X X X STEEL CONSTRUCTION (OTHER THAN STRUCTURAL STEEL) 1705.2.2 1. MATERIAL VERIFICATION OF COLD-FORMED STEEL DECK: A. IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS, B. MANUFACTURER'S CERTIFIED TEST REPORTS. 2. INSPECTION OF WELDING: A. COLD-FORMED STEEL DECK: 1. FLOOR AND ROOF DECK WELD X X MASONRY -LEVEL A QUALITY ASSURANCE 1705.4 1. VERIFY COMPLIANCE WITH APPROVED SUBMITTALS. 2. AS MASONRY CONSTRUCTION BEGINS, VERIFY THAT THE FOLLOWING ARE IN COMPLIANCE: A. PROPORTIONS OF SITE-PREPARED MORTAR 3. PRIOR TO GROUTING, VERIFY THAT THE FOLLOWING ARE IN COMPLIANCE: A. PROPORTIONS OF SITE-PREPARED GROUT B. CONSTRUCTION OF MORTAR JOINTS 4. VERIFY DURING CONSTRUCTION: A. PREPARATION, CONSTRUCTION, AND PROTECTION OF MASONRY DURING COLD WEATHER (TEMPERATURES BELOW 40 DEGREES) OR HOT WEATHER (TEMPERATURES ABOVE 90 DEGREES) B. PLACEMENT OF GROUT X X X X X X X www.kengsc.com Project number Date Drawn by Checked by SEAL: COPYRIGHT 2018 K.ENG LLC SHEET NUMBER: TITLE: FIRM ILLINOIS LICENSE NO. 184-004153 KDK KDK S1.1 SPECIAL INSPECTIONS 18-1015 232 E MAIN ST. ASPEN, CO CORE AND SHELL BUILDING 6-14-2018 STATEMENT OF SPECIAL INSPECTIONS 1. SPECIAL INSPECTIONS AND STRUCTURAL TESTING SHALL BE PROVIDED BY AN INDEPENDENT AGENCY EMPLOYED BY THE OWNER FOR THE ITEMS IDENTIFIED IN THIS SECTION AND IN OTHER AREAS OF THE APPROVED CONSTRUCTION PLANS AND SPECIFICATIONS, UNLESS WAIVED BY THE BUILDING OFFICIAL (SEE IBC CHAPTER 17). 2. THE NAMES AND CREDENTIALS OF THE SPECIAL INSPECTORS TO BE USED SHALL BE SUBMITTED TO THE BUILDING OFFICIAL FOR APPROVAL. 3. DUTIES OF THE SPECIAL INSPECTOR: A. THE SPECIAL INSPECTOR SHALL REVIEW ALL WORK LISTED BELOW FOR CONFORMANCE WITH THE APPROVED CONSTRUCTION PLANS AND SPECIFICATIONS AND THE 2012 IBC. B. THE SPECIAL INSPECTOR SHALL FURNISH SPECIAL INSPECTION REPORTS TO THE EOR, CONTRACTOR, OWNER AND BUILDING OFFICIAL ON A WEEKLY BASIS, OR MORE FREQUENTLY AS REQUIRED BY THE BUILDING OFFICIAL. ALL ITEMS NOT IN COMPLIANCE SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION, AND IF UNCORRECTED, TO THE EOR AND THE BUILDING OFFICIAL. C. ONCE CORRECTIONS HAVE BEEN MADE BY THE CONTRACTOR, THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL SIGNED REPORT TO THE BUILDING O FFICIAL STATING THAT THE WORK REQUIRING SPECIAL INSPECTION WAS,TO THE BEST OF THE SPECIAL INSPECTOR’S KNOWLEDGE, IN CONFORMANCE WITH THE APPROVED CONSTRUCTION PLANS AND SPECIFICATIONS AS WELL AS THE APPLICABLE WORKMANSHIP PROVISIONS OF THE 2012 IBC. 4. DUTIES AND RESPONSIBILITIES OF THE CONTRACTOR: A. THE CONTRACTOR SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE OWNER AND THE BUILDING OFFICIAL PRIOR TO THE COMMENCEMENT OF WORK. IN ACCORDANCE WITH IBC 1704.4, THE STATEMENT OF RESPONSIBILITY SHALL CONTAIN ACKNOWLEDGEMENT OF THE SPECIAL INSPECTION REQUIREMENTS CONTAINED WITHIN THIS “STATEMENT OF SPECIAL INSPECTIONS”. B. THE CONTRACTOR SHALL NOTIFY THE RESPONSIBLE SPECIAL INSPECTOR THAT WORK IS READY FOR INSPECTION AT LEAST ONE WORKING DAY (24 HOURS MINIMUM) BEFORE SUCH INSPECTION IS REQUIRED. C. ALL WORK REQUIRING SPECIAL INSPECTION SHALL REMAIN ACCESSIBLE AND EXPOSED UNTIL IT HAS BEEN OBSERVED BY THE SPECIAL INSPECTOR. 5. PLEASE SEE THE “SPECIAL INSPECTION SCHEDULE”FOR THE TYPES, EXTENTS AND FREQUENCY OF SPECIFIC ITEMS REQUIRING SPECIAL INSPECTIONS AND STRUCTURAL TESTS AS PART OF THIS PROJECT. 6. CONTINUOUS INSPECTION MEANS THAT THE SPECIAL INSPECTOR IS ON SITE AT ALL TIMES OBSERVING THE WORK REQUIRING SPECIAL INSPECTION. PERIODIC INSPECTION MEANS THAT THE SPECIAL INSPECTOR IS ON SITE AT TIME INTERVALS NECESSARY TO CONFIRM THAT ALL WORK REQUIRING INSPECTION IN IS COMPLIANCE. 7. INSPECTION FOR PREFABRICATED CONSTRUCTION SHALL BE THE SAME AS IF THE MATERIAL USED IN THE CONSTRUCTION TOOK PLACE ON SITE. CONTINUOUS INSPECTION WILL NOT BE REQUIRED DURING PREFABRICATION IF THE APPROVED AGENCY CERTIFIES THE CONSTRUCTION AND FURNISHES EVIDENCE OF COMPLIANCE. 8. INSPECTION OF DRILLED CONCRETE OR MASONRY ANCHORS, INCLUDING UNDERCUT, EXPANSION, AND ADHESIVE, SHALL INCLUDE VISUAL VERIFICATION OF ANCHOR TYPE, DIMENSIONS OF DRILLED HOLE DEPTH, SPACING, AND EDGE DISTANCES, HOLE CLEANING, ANCHOR EMBEDMENT AND TIGHTENING TORQUE IN ACCORDANCE WITH PUBLISHED MANUFACTURER DATA (LATEST AVAILABLE INFORMATION.) EXP 10-31-21 No.Description Date 1 PERMIT 9-25-2018 2 ISSUE FOR BID 11-28-2018 14 WESTERN WOOD COORD.9-18-2020 12/02/2020 A A B C D F G C.2 1 2 3 4 5 6 7 8 D.4 E.8 F.8 9 8.5 10 OFFICE LL = 50PSF SDL = 15PSF PARTITIONS ROOF DECK LL = 100PSF SDL = PAVER SYSTEM @ 30 PSF ROOF SL = 70 PSF SDL = MECH UNITS ROOF SL = 70 PSF SDL = MECH UNITS 7.5 F.9A.1 9.8 A.2 5.8 6.86.9 A A B C D F G C.2 1 2 3 4 5 6 7 8 D.4 E.8 F.8 9 8.5 10 INTERIOR ZONE 1 EDGE ZONE 2 TYP CORNER ZONE 3 EFFECTIVE WIND AREA (IBC DEFINITION)ZONE 1 ZONE 2 AREA 100 SQ FT AND MORE +7.7 PSF / -21.8 PSF +7.7 PSF / -25.8 PSF +16 PSF / -25.8 PSF (INCLUDES JOISTS) AREA 50 SQ FT AND LESS +8.3 PSF / -22.4 PSF +8.3 PSF / -30.1 PSF +8.3 PSF / -36.1 PSF AREA 10 SQ FT AND LESS +9.7 PSF / -23.8 PSF +9.7 PSF / -39.9 PSF +9.7 PSF / -60.1 PSF (INCLUDES ROOF DECKING) + = DOWN FORCE -= UPLIFT FORCE ZONE 3 TYP 5' - 6" 7.5 F.9A.1 9.8 5.8 6.86.9 A A B C D F G C.2 E 1 2 3 4 D.4 E.8 F.8 9 8.5 10 INTERIOR ZONE 1 CORNER ZONE 3 EFFECTIVE WIND AREA (IBC DEFINITION)ZONE 1 ZONE 2 AREA 10 SQ FT AND LESS +21.8 PSF / -23.8 PSF +21.8 PSF / -27.9 PSF +21.8 PSF / -27.9 PSF (INCLUDES ROOF DECKING) AREA 20 SQ FT AND LESS +21.2 PSF / -22.6 PSF +21.2 PSF / -26.6 PSF +21.2 PSF / -26.6 PSF AREA 50 SQ FT AND MORE +20.4 PSF / -21PSF +20.4 PSF / -25 PSF +20.4 PSF / -25 PSF (INCLUDES JOISTS) + = DOWN FORCE -= UPLIFT FORCE ZONE 3 EDGE ZONE 2 TYP TYP 5' - 6" 5' - 6" 7.5 F.9 A.1 A.1 9.8 A.2 A.2 5.8 6.86.9 www.kengsc.com Project number Date Drawn by Checked by SEAL: COPYRIGHT 2018 K.ENG LLC SHEET NUMBER: TITLE: FIRM ILLINOIS LICENSE NO. 184-004153 KDK KDK S1.2 LOADING DIAGRAMS 18-1015 232 E MAIN ST. ASPEN, CO CORE AND SHELL BUILDING 6-14-2018 1" = 10'-0"S1.2 1 SECOND FLOOR LOADING PLAN 1" = 10'-0"S1.2 2 SECOND FLOOR LEVEL COMPONENT AND CLADDING WIND LOADS 1" = 10'-0"S1.2 3 ROOF COMPONENT AND CLADDING WIND LOADS EXP 10-31-21 No.Description Date 1 PERMIT 9-25-2018 2 ISSUE FOR BID 11-28-2018 14 WESTERN WOOD COORD.9-18-2020 12/02/2020 A A B C D F G C.2 E 1 2 3 4 5 D.4 E.8 F.8 9 8.5 10 BALANCED SNOW LOAD = 60 PSF BALANCED SNOW LOAD (E TO G) = 70 PSF CASE 1 BALANCED SNOW LOAD (A TO E) = 70 PSF VALLEY SL = 140PSF RIDGE SL = 35PSF CASE 2 UNBALANCED SNOW LOAD 7.5 F.9A.1 9.8 24 ' - 2 1 / 8 " 5.8 6.86.9 HI E G H T = G R A D E T O P A R A P E T OVERWALL BUILDING DIMENSION (LENGTH OR WIDTH) 5' - 6"5' - 6" INTERIOR ZONE 4EDGE ZONE 5 EDGE ZONE 5 EFFECTIVE WIND AREA (IBC DEFINITION)ZONE 4 ZONE 5 AREA 10 SQ FT AND LESS +/-23.6 PSF +/-29.1 PSF AREA 50 SQ FT AND LESS +/-21.3 PSF +/-24.6 PSF www.kengsc.com Project number Date Drawn by Checked by SEAL: COPYRIGHT 2018 K.ENG LLC SHEET NUMBER: TITLE: FIRM ILLINOIS LICENSE NO. 184-004153 KDK KDK S1.3 LOADING DIAGRAMS 18-1015 232 E MAIN ST. ASPEN, CO CORE AND SHELL BUILDING 6-14-2018 1" = 10'-0"S1.3 1 ROOF SNOW LOADS 1/4" = 1'-0"S1.3 2 EXTERIOR WALL COMPONENT AND CLADDING WIND PRESSURES EXP 10-31-21 No.Description Date 1 PERMIT 9-25-2018 2 ISSUE FOR BID 11-28-2018 14 WESTERN WOOD COORD.9-18-2020 12/02/2020 A A B C D F G C.2 1 2 3 4 5 6 7 8 D.4 E.8 F.8 9 8.58.5 10 10 10'-8 1/4"10'-11 1/4"11'-2 1/2"10'-6"9'-9 1/2"10 1/2" 5' - 0 " 6' - 1 0 7 / 8 " 11 ' - 7 7 / 8 " 12 ' - 6 1 / 8 " 4' - 2 3 / 4 " 13 ' - 3 1 / 4 " 13 ' - 3 1 / 4 " 13 ' - 3 1 / 2 " 13 ' - 9 3 / 4 " 2'-10 3/8" TC2 P3 F8 M1 M2 TC2 P3 F3 TC1 P3 TC1 P1 F1 TC1 P1 F1 5" SLAB-ON-GRADE OVER ENGINEERED FILL REINF. W/ 6X6 W2.9XW2.9 WWF T/SLAB = +0' -0" (= 7903.20' CIVIL DATUM) 1 S4.0 M1 T/SLAB = -1' -0" 2 S4.0 18 S4.0 16 S4.0 T/SLAB = -2' -8" 5 S4.0 5 1/2" CLT WALL PANEL BY OTHERS L2 L3 7 S4.0 TC3 P4 F1 TC3 P4 F5 TC3 P4 F5 TC3 P4 F5 T/PIER = -0' -8" 6 S4.0 8 S4.1 10 S4.0 11 S4.0 M1 M2 STEP FTG 7 S4.0 8 S4.0 7 S4.0 14 S4.0 24' - 5 7/8"9' - 4 7/8"8' - 4"9' - 4 3/4" B/FTG = -3' -0" 1 S4.1 5' - 4 1/4" 5' - 9 " 3' - 9 3 / 4 " 5' - 0 7 / 8 " 4' - 1 1 1 / 8 " 13' - 11 3/4"9' - 0" 4 5/8"3' - 4"18' - 2 1/8"3' - 4" 1' - 10 7/8" 2' - 0" B/FTG = -11’-5”B/FTG = -8’-10” 15 S4.0 M5 M4 WOOD PARTITION WALLS NOTE: ALL FOOTINGS TO BEAR UPON ENGINEERED FILL OR APPROVED SUBBASED AS PER THE GEOTECHNICAL REPORT. CONFIRM ALL SOIL IMPROVEMENT REQUIREMENTS WITH GEOTECHNICAL REPORT B/FTG = -7' -5" EQ 6' - 0"EQ T/SLAB = -1' -11 1/4" 5' - 1 1 / 4 " 8' - 2 1 / 4 " 6' - 9 5/8" DRYWELL -SEE CIVIL DWGS B/WELL = -13' -3" B/FTG = -13' -3" B/FTG = -7' -10" B/FTG = -11' -8 1/2" MATCH EXISTING B/FTG = -3' -3 1/2" MATCH EXISTING B/FTG = -4' -7 1/2" MATCH EXISTING ALONG COL. LINE A B/COLUMN FTG = -8' -4"B/COLUMN FTG = -4' -9" 3" B/FTG = -5' -2" STEP FTG 4 S4.0 4 S4.0 A T/FTG = -5' -2" B/FTG = -4' -0" B/FTG = -4' -6" 13 S4.0 INFILL BLOCK PER SCHEDULE (M1) AFTER ELEV. INSTALL 16 S4.2 @ LINTEL A 13 S4.0 17 S4.0 +/ - 1 ' - 6 7 / 8 " 9' - 0 " 3 S4.0 B/FTG = -4' -7 1/2" 3 S4.1 4 S4.1 EARTH RETENTION (BY OTHERS) IS REQUIRED 7.5 M21' - 9 7/8" 5" F.9A.1 1' - 0 3/4"9' - 7 1/2" 12' - 0"TO CMU 1' - 0" 2' - 0"12' - 0" 3"14' - 0" 9.8 2' - 0" A.2 3"2' - 8" 12 ' - 7 " 5' - 9 3 / 4 " 5' - 6 3 / 4 " 8' - 0 " 7' - 3 3 / 4 " 5' - 1 1 3 / 4 " TC2 F1 P3 TC2 P3 F4 TC2 P3 F4 TC2 P3, F4 TC4 P5 F6 T/PIER = -1' -0" 5 1/2" CLT WALL PANEL BY OTHERS 5 1/2" CLT WALL PANEL BY OTHERS 1' - 2 " M2 M2 3'-3" 1'-5"13'-3" 6"14'-8"6" TC1 P2 F7 TC1 2'-1" 10" 4' - 2 3 / 4 " 13 ' - 3 1 / 4 " 13 ' - 3 1 / 4 " 13 ' - 3 1 / 2 " 3' - 9 3 / 4 " 9' - 1 " 11 " B/FTG = -12' -3" 5'-6"2'-0"2'-0"2'-0"4'-2" M2 B/FTG = -3' -0" 2 S4.1 T/FTG = -6' -2" 3' - 5 3 / 8 " 4'-1" 6 S4.0 4'-3 7/8" 5 7/8" M1 10'-8" 6" 2'-1" 7 1/2" 2' - 6 " 2' - 6 " 1 S4.1 5 S4.1 2'-11 1/2" 8 S4.1 STEP T/FTG = -7' -2" 4 3 / 8 " 6 S4.1 2'-4 1/2" 2' - 6 " 21'-9 7/8" B/FTG = -3' -0" B/FTG = -3' -0" B/FTG = -3' -0" 1' - 2 1 / 2 " 1'-2"T/CONC. WALL +0' -0" 19 S4.0 7 S4.1 19 S4.0 19 S4.0 7 3/8" C TO C HOLD-DOWNS 5'-8"6" 6" C TO C HOLD-DOWNS 11'-7" 6" 2" B/FTG = -10’-2” T/FTG -8' -2" B/FTG = -8’-10” STEP T/FTG = -5' -10" B/FTG = -5' -10" B/FTG = -11' -3" B/FTG = -9’-10” 2" 2" 2" S4.1 9 T/CONC. WALL +0' -8" T/CONC. WALL +0' -8" 6.86.9 2'-0" SL A B S L O P E S T/SLAB = -2' -2" 11 S4.1 10 S4.1 2'-6" 13 S4.0 4 S4.0 C SLOPE T/SLAB = -1' 1 11/16" 1'-0" T/SLAB = -1' -0" A A B C D F G C.2 1 2 3 4 5 6 7 8 D.4 E.8 F.8 9 8.58.5 10 10'-8 1/4"10'-11 1/4"11'-2 1/2"10'-6"10'-8" 6'-10 7/8" 11'-7 7/8" 12'-6 1/8" 4'-2 3/4" 13'-3 1/4" 13'-3 1/4" 13'-3 1/2" 8'-10 5/8" 4'-11 1/8" 3'-9 3/4" 5'-0 7/8" 24'-5 7/8"27'-1 5/8" 9'-4 7/8"8'-4"9'-4 3/4" 4 S4.2 7 S4.2 5 S4.2 L3 17 S4.2 INFILL BLOCK PER SCHEDULE AFTER ELEV. INSTALL 16 S4.2 @ LINTEL 7.5 F.9A.1 9.8 A.2 5.8 6.7 6.86.9 TIMBER FRAMED WOOD WITH CLT PANELS REFER TO STAMPED AND SIGNED DRAWINGS BY WESTEN WOOD STRUCTURES, INC. CLT WALL PANELS TIMBER BEAM DOES NOT BEAR ON MASONRY TIMBER BEAM DOES NOT BEAR ON MASONRY TIMBER BEAM DOES NOT BEAR ON MASONRY 6 S4.2 8 S4.2 SPAN DIRECTION OF CLT PANELS 9 S4.2 10 S4.2 11 S4.2 FACE MOUNTED STEEL BRACKET -SEE WESTERN WOOD DRAWINGS TIMBER BEAM DOES NOT BEAR ON MASONRY BEAM BEARS OVER CMU ON SIMPSON GLB SEAT SEE WESTERN WOOD DRAWINGS BEAM BEARS OVER CMU ON SIMPSON GLB SEAT SEE WESTERN WOOD DRAWINGS 12 S4.2 13 S4.2 14 S4.2 15 S4.2 7 S4.3 www.kengsc.com Project number Date Drawn by Checked by SEAL: COPYRIGHT 2020 K.ENG LLC SHEET NUMBER: TITLE: FIRM ILLINOIS LICENSE NO. 184-004153 KDK KDK S2.0 FIRST AND SECOND FLOOR PLANS 18-1015 232 E MAIN ST. ASPEN, CO CORE AND SHELL BUILDING 6-14-2018 3/16" = 1'-0"S2.0 1 FIRST FLOOR FOUNDATION PLAN EXP 10-31-21 3/16" = 1'-0"S2.0 2 SECOND FLOOR FRAMING PLAN No.Description Date 1 PERMIT 9-25-2018 2 ISSUE FOR BID 11-28-2018 4 PERMIT CORRECTION 12-18-2019 5 CONSTRUCTION 5-27-2020 6 FOUNDATION REVIEW 7-24-2020 7 FOUNDATION - TIMBER COOR. 8-7-2020 8 FOUNDATION - TIMBER FINAL 8-13-2020 10 WESTERN WOOD COOR.8-15-2020 11 CENTAUR FTG ELEV COOR. 8-25-2020 12 MODIF COORDINATION 9-2-2020 13 PERMIT REVISION 9-4-2020 14 WESTERN WOOD COORD.9-18-2020 16 CONSTRUCTION DOCUMENT REVISION 10-5-2020 17 CONSTRUCTION REVISIONS 10-15-2020 18 CONSTRUCTION REVISION 10-16-2020 19 CONSTRUCTION REVISIONS 10-26-2020 PROVIDE MASONRY, FOUNDATION, AND LATERAL DESIGN CALCULATIONS COLUMN SIZE DOESN'T MATCH CLT DRAWINGS AT TC4 - PLEASE CLARIFY COLUMN SIZE DOESN'T MATCH CLT DRAWINGS (TYP) AT TC2 - PLEASE CLARIFY CLT DRAWINGS INDICATE A GLULAM COLUMN HERE - PLEASE CLARIFY CLT DRAWINGS INDICATE A GLULAM COLUMN HERE - PLEASE CLARIFY 12/02/2020 A A B C D F G C.2 E 1 2 3 4 D.4 E.8 F.8 9 8.5 10 10'-8 1/4"10'-11 1/4"16'-5 1/2"15'-11" 5'-3"5'-3" 6' - 1 0 7 / 8 " 11 ' - 7 7 / 8 " 12 ' - 6 1 / 8 " 52 ' - 1 1 1 / 4 " 4' - 1 1 1 / 8 " 5' - 0 7 / 8 " 24'-5 7/8"9'-4 7/8"8'-4"9'-4 3/4" 1 S4.2 2 S4.2 3 S4.2 5 S4.3 6 S4.3 7.5 F.9A.1 5.8 6.86.9 TIMBER FRAMED WOOD WITH CLT PANELS REFER TO STAMPED AND SIGNED DRAWINGS BY WESTEN WOOD STRUCTURES, INC. TIMBER FRAMED WOOD WITH CLT PANELS REFER TO STAMPED AND SIGNED DRAWINGS BY WESTEN WOOD STRUCTURES, INC. CLT WALL PANELS SPAN DIRECTION OF CLT PANELS SLOPED BEAM SEAT- SEE WESTERN WOOD DRAWINGS SLOPED BEAM SEAT- SEE WESTERN WOOD DRAWINGS 19 S4.2 1 S4.3 2 S4.3 3 S4.33 S4.3 4 S4.3 4 S4.3 SIMILAR NO BOND BEAM BEAM BEARS OVER CMU ON SIMPSON GLB SEAT CENTERED OVER WALL SEE WESTERN WOOD DRAWINGS D.4 E.8 8.5 W12X26 HOIST BEAM -LOCATE PER ELEVATOR MANUFACTURER CLT PANEL BY WESTERN WOOD 18 S4.2 18 S4.2 18 S4.2 18 S4.2 www.kengsc.com Project number Date Drawn by Checked by SEAL: COPYRIGHT 2020 K.ENG LLC SHEET NUMBER: TITLE: FIRM ILLINOIS LICENSE NO. 184-004153 KDK KDK S2.1 ROOF FRAMING PLANS 18-1015 232 E MAIN ST. ASPEN, CO CORE AND SHELL BUILDING 6-14-2018 3/16" = 1'-0"S2.1 1 ROOF FRAMING PLAN EXP 10-31-21 3/16" = 1'-0"S2.1 2 ELEVATOR OVERRUN No.Description Date 1 PERMIT 9-25-2018 2 ISSUE FOR BID 11-28-2018 3 PERMIT CORRECTIONS 8-9-2019 4 PERMIT CORRECTION 12-18-2019 14 WESTERN WOOD COORD.9-18-2020 PROVIDE MASONRY AND LATERAL DESIGN CALCULATIONS 12/02/2020 MARK COLUMN TC1 6 3/4"x9" TIMBER COLUMN SCHEDULE -BY OTHERS, FOR REFERENCE ONLY TC2 8 3/4"x9" TC3 6 3/4"x30" TC4 6 3/4"x21 1/2" TIMBER COLUMN TOP OF PIER = 0' -0" TYP SEE PLAN FOR PIERS NOTED WITH DIFFERENT T/PIER ELEVATIONS BE T W E E N P L A T E S 6 7 / 8 " C L E A R 9"1 1 / 2 " 1' - 0 " 1 1 / 2 " TC1 COLUMN 3/4" DIA. HILTI KWIK BOLT III W/ 4 1/4" EMBEDMENT, TYPICAL 1" NON-SHRINK 5000psi GROUT BED 1/2" BASE PLATE 3" 7 1 / 2 " 3" 3" 1/4" PLATE W/ (2) 3/4" DIA. BOLTS 1/4 BE T W E E N P L A T E S 8 7 / 8 " C L E A R 9"1 1 / 2 " 1' - 2 " 1 1 / 2 " TC2 COLUMN 3/4" DIA. ANCHOR RODS 1/2" BASE PLATE 1/4 8 3 / 4 " 1' - 3 " 1 1 / 2 " 1' - 0 " 1 1 / 2 " 2"2'-2"2" TIMBER COLUMN 5" 1/4" PLATE W/ (4) 3/4" DIA. BOLTS 3 1 / 4 " 3" 3 1/2"1 3/4" BE T W E E N P L A T E S 6 7 / 8 " C L E A R 6 3 / 4 " 2'-6" TC3 COLUMN 1' - 3 " 1 1 / 2 " 1' - 0 " 1 1 / 2 " 2"1'-5 1/2"2" BE T W E E N P L A T E S 6 7 / 8 " C L E A R 6 3 / 4 " 1'-9 1/2" TC4 COLUMN 4 1 / 4 " 4 1 / 4 " CONCRETE PIER REINF. LAYOUT AND DIMENSIONS #4 TIES @ 12" O.C. (6) #6 DOWELS WITH STD. HOOKS INTO FOOTING 1' - 0 1 / 4 " 2' - 0 " 1'-4" P1 1'-0 3/4" 1' - 0 1 / 4 " 2' - 0 " 1'-10" P2 (6) #6 DOWELS WITH STD. HOOKS INTO FOOTING 1' - 1 0 " 1'-4" P3 (4) #6 DOWELS WITH STD. HOOKS INTO FOOTING 1'-8" 2' - 1 0 " 10" 11 " 8" P4 (8) #6 DOWELS WITH STD. HOOKS INTO FOOTING 1'-8" 2' - 9 " 10" P5 (8) #6 DOWELS WITH STD. HOOKS INTO FOOTING 8 1 / 2 " 11 " 1' - 1 1 / 2 " 1' - 5 " 1' - 5 " SEE 1/S3.0 FOR PIER ELEVATIONS FOOTING SCHEDULE (BEARING 4000PSF) MARK SIZE REINFORCEMENT COMMENTS F2 NOT USED F1 3' - 9" X 3' - 9" X 12" (12) #3 EACH WAY, BOTTOM F3 5' - 0" X 5' - 0" X 12" (8) #4 EACH WAY, BOTTOM F4 5' - 0" X 3' - 6" X 12" (7) #4 EACH WAY, BOTTOM N-S WALL AND FOOTING REBAR TO PASS THROUGH FTG F5 3' - 0" X 3' - 0" X 12" (8) #3 EACH WAY, BOTTOM F6 4' - 0" X 4' - 6" X 12" (6) #4 EACH WAY, BOTTOM E-S WALL FOOTING REBAR TO PASS THROUGH FTG F7 3' - 0" X 3' - 0" X 12" (8) #3 EACH WAY, BOTTOM N-S WALL AND FOOTING REBAR TO PASS THROUGH FTG F8 3' - 0" X 4' - 9" X 12" (5) #4 LONG WAY, BOTTOM (7) #4 SHORT WAY, BOTTOM LOOSE LINTEL SCHEDULE MARK SIZE BEARING REQ'D COMMENTS L1 (2)L3 1/2X3 1/2X1/4 4" L2 W12X19 6" PROVIDE 1/4” BOTTOM PLATE AND 1/2" DIA. X 4" LONG HEADED STUDS @ 32" O.C. L3 W8X10 6" PROVIDE 1/4” BOTTOM PLATE AND 1/2" DIA. X 4" LONG HEADED STUDS @ 32" O.C. MASONRY WALL SCHEDULE (STRUCTURAL) MARK BLOCK SIZE LEVELSVERTICAL REINFORCMENT COMMENTS M1 8" CMU #4 @ 32" O.C. (TYPICAL)GROUND TO PARAPET #4 @ 8" O.C. (FOR 2' - 0" EACH SIDE OF OPENINGS) OR ROOF ADDITIONAL MASONRY NOTES: 1. PROVIDE DOWELS, EITHER #4 X 48" OR #5 X 60" LONG TO MATCHING SIZE AND SPACING OF VERTICAL MASONRY REINFORCING INTO FOUNDATION WALL. DOWELS SHALL EXTEND HALFWAY INTO FOUNDATION WALL AND TIED TO FOUNDATION VERTICAL REINFORCING. HOOKED DOWELS (12” MIN.) ARE TO BE PROVIDED AT FOOTINGS. 2. ALL VERTICAL BARS TO BE CONTACT LAP SPLICED AS THE LENGTHS PROVIDED IN THE MASONRY NOTES ON SHEET S1.0. 3. ALL MASONRY TO HAVE f'm = 2000 PSI. REFER TO MASONRY NOTES ON SHEET S1.0. 4. ALL WALLS TO HAVE MASONRY BOND BEAM COURSES AS FOLLOWS (UNLESS NOTED OTHERWISE IN SCHEDULE): PROVIDE BOND BEAMS AT ROOF/FLOOR LINES (BELOW JOIST BEARING) SEE WALL SECTIONS AND AT TOP OF PARAPET. 5. ALL MASONRY WALLS TO BE PROVIDED WITH 8 GAGE GALVANIZED TRUSS TYPE JOINT REINFORCEMENT SPACED AT 16" O.C. VERTICALLY. REFER TO MASONRY NOTES ON SHEET S1.0. 6. WALL REINFORCEMENT SPECIFIED TO CONTINUE ABOVE MASONRY OPENINGS. 7. ALL MASONRY REINFORCEMENT INDICATED ABOVE TO BE CENTERED IN CORE, 8. IN NO INSTANCE SHALL MORTAR BE USED AS A SUBSTITUTE FOR GROUT. ALL REINFORCING, WHETHER VERTICAL OR HORIZONTAL, SHALL BE EMBEDDED IN GROUTED CELLS. M3 NOT USED M2 10" CMU #5 @ 8" O.C. (TYPICAL)GROUND TO ROOF OR SECOND FLOOR M4 6" CMU #4 @ 32" O.C. GROUND TO ROOF M5 10" CMU #4 @ 32" O.C. GROUND TO ROOF GROUT WALL SOLID VERTICAL WALL REINFORCING -SEE SCHEDULE FOR SIZE AND SPACING MASONRY WALL - SEE SCHEDULE TYPICAL WALL REINFORCING CENTERED ON CELLS TYPICAL REINFORCEMENT PLACEMENT TYPICAL REINFORCEMENT PLACEMENT AT END WALL CONDITION (2) VERTICAL BARS SPACED 8" O.C. BAR SIZE TO MATCH TYPICAL WALL REINFORCING. MASONRY WALL - SEE SCHEDULE T/ 3 3" TO VERT. BAR 36 BAR DIA.T/4 T NOTE: LOCATE CMU CONTROL JOINTS @ 24'-0" O.C. MAX. VERTICAL JOINT CONT. FROM TOP OF FOOTING TO TOP OF PARAPET. PACK JOINT W/DUR-O-WALL EXPANSION. JOINT FILLER AND CAULK EACH SIDE. 2-#5 VERT. IN CELL @ EACH SIDE OF JOINT. HORIZ. REBAR ACROSS JOINT (#5 @ 96" O.C. TO BE CONTINUOUS ACROSS JOINT WRAP BAR WITH SCHED. 125 PVC PIPE FOR FIRST 30" EACH SIDE OF CMU CONTROL JOINTS.) WATERSTOP BELOW GRADE TYPICAL TY P I C A L OR 1'-6" MIN. 24" CORNER BARS #5 CORNER BARS, TYPICAL 4 S3.0 TYPICAL WALL CONSTRUCTION JOINT 5 S3.0 TYPICAL CORNER & INTERSECTION MASONRY WALL DETAILS 6 S3.0 TYPICAL MASONRY CONTROL JOINT 1'-0" 8" 1'-0" 1/ 4 T SAW CUT CONTROL JOINT SLAB ON GRADE W.W.F. CONTROL JOINT FILLER NOTE:SAW CUT SLAB WITHIN 12 HOURS AFTER SLAB HAS BEEN PLACED. T = SLAB THICKNESS CONTROL JOINT FILLER SAWCUT SLAB ON GRADE NOTE: ANY MATERIALS USED IN FORMING KEY JOINT MUST BE REMOVED 2X4 KEY CONSTRUCTION JOINT 1/ 2 T (M I N . ) T CONTROL JOINT 4 1 1 4 1 2 7 S3.0 TYPICAL SLAB JOINT DETAILS SLAB-ON-GRADE JOINTS SHALL BE SPACED IN TWO ORTHAGONAL DIRECTIONS AT NOT MORE THAN 15 FT O.C. FOR A 5" THICK SLAB AND NOT MORE THAN 12 FT O.C. FOR A 4" THICK SLAB. 2 "H" MIN. "H " D I M . SE E PL A N "D " "D" "D " CONT. FOOTINGBARS TO MATCH CONT. FOOTING REINF. CONT. FOOTING MIN. 1 1/2 MIN. 1 8 S3.0 TYPICAL STEPPED FOOTING DETAIL www.kengsc.com Project number Date Drawn by Checked by SEAL: COPYRIGHT 2020 K.ENG LLC SHEET NUMBER: TITLE: FIRM ILLINOIS LICENSE NO. 184-004153 KDK KDK S3.0 SCHEDULES AND TYPICAL DETAILS 18-1015 232 E MAIN ST. ASPEN, CO CORE AND SHELL BUILDING 6-14-2018 3/4" = 1'-0"S3.0 1 TYPICAL BASE PLATE DETAIL 3/4" = 1'-0"S3.0 2 PIER DETAILS 1" = 1'-0"S3.0 3 NOT USED EXP 10-31-21 No.Description Date 1 PERMIT 9-25-2018 2 ISSUE FOR BID 11-28-2018 4 PERMIT CORRECTION 12-18-2019 5 CONSTRUCTION 5-27-2020 6 FOUNDATION REVIEW 7-24-2020 7 FOUNDATION - TIMBER COOR. 8-7-2020 8 FOUNDATION - TIMBER FINAL 8-13-2020 13 PERMIT REVISION 9-4-2020 14 WESTERN WOOD COORD.9-18-2020 17 CONSTRUCTION REVISIONS 10-15-2020 12/02/2020 COMPACTED FILL (2) #4 BOTTOM SLAB-ON-GRADE #4 DOWELS @ 18" O.C. SIDEWALK - SEE CIVIL. DWGS 12" 20" 8" 1' - 0" 1' - 0 1/4" 3' - 0 " M I N . FOOTING TO BEAR UPON ENGINEERED FILL OR APPROVED SUBBASED AS PER THE GEOTECHNICAL REPORT 2' - 0" 1' - 0 " 3" 1' - 2" GRADE #4 @ 8" HORZ. #4 @ 16" O.C. VERT. W/ 12" HOOK (3) #4 MASONRY WALL - SEE PLAN PROPERTY LINE EXISTING BUILDING W/ BASEMENT MATCH BOTTOM OF EXISTING FOOTING, V.I.F. SLAB-ON-GRADE 1/2" FIBER EXP. JOINT SPLICE 30" LAP COMPACTED STONE SEE PLAN FIRST FLOOR RIGID NON- COMPRESSIBLE INSULATION 2' - 0" 1' - 0" 3" 1' - 2" #4 @ 8" HORZ. #4 @ 16" O.C. VERT. W/ 12" HOOK (3) #4 MASONRY WALL - SEE PLAN PROPERTY LINE EX I S T I N G B U I L D I N G MATCH BOTTOM OF EXISTING FOOTING, V.I.F. SLAB-ON-GRADE 1/2" FIBER EXP. JOINT PROVIDE BOND BREAKER SPLICE 30" LAP SEE PLAN 1' - 0" @ 4A VARIES @ SECT 4C 1' - 0" @ SECT 4 8" 1 1 SLAB-ON-GRADE OVER ENGINEERED FILL (4) #4 BOTTOM MASONRY WALL -SEE PLAN SLAB-ON-GRADE COMPACTED FILL 2' - 6" 1' - 0" #4 @ 8" HORZ. #4 @ 16" O.C. VERT. W/ 12" HOOK 8"1' - 0"10" #4 @ 9”BOTTOM SIDEWALK SEE PLAN 1/2" FIBER EXP. JOINT 10" 10 3/4" T/WALL = -2' -0" (4) #4 BOTTOM SLAB-ON-GRADE, ELEV. VARIES COMPACTED FILL 2' - 6" 1' - 0" #4 @ 8" HORZ. #4 @ 16" O.C. VERT. W/ 12" HOOK 10"10"10" #4 @ 12”BOTTOM SIDEWALK SEE PLAN 1/2" FIBER EXP. JOINT CLT WALL -BY OTHERS 5/8" DIA. x 7" LONG GALVANIZED HILTI KWIK BOLT III @ 18" O.C. 3 1/2" EMBEDMENT COUNTERSUNK INTO SILL BEAM 4X6 SOUTHERN PINE 9" 3 1/2" 3 3/4" T/WALL = -1' -4" COMPACTED FILL (2) #4 BOTTOM SLAB-ON-GRADE GRADE SLOPES SIDEWALK -SEE CIVIL DWGS 4 1/2" 1' - 2" VARIES 1/2" FIBER EXP. JOINT 3' - 0" MIN. (2) #4 #4 X 16" LONG @ 18" O.C. 9 1/2" #4 DOWELS @ 18" O.C.12" 20" 8" (11) #4 TOP & BOTTOM SLAB-ON-GRADE COMPACTED FILL 5' - 0" 1' - 0" #4 @ 8" HORZ. EACH FACE #4 @ 16" O.C. VERT. W/ 12" HOOK, EACH FACE 1' - 6 1/2"2' - 0"1' - 5 1/2" #4 @ 12”TOP & BOTTOM SIDEWALK -SEE CIVIL DWGS SEE PLAN 6" 5' - 0". 10" 1'-0" 1'-2" SLAB-ON- GRADE -SEE PLAN MASONRY WALL-SEE PLAN #5 @ 10" TOP AND BOTTOM, EACH WAY #4 @ 12" O.C. (H) #4 DOWELS WITH STD HOOK @ 8" O.C. SEE PLAN 8" PROVIDE SUMP PIT 12/S4.0 AT SOUTHWEST CORNER #4 @ 12" O.C. EACH WAY, CENTERED COMPACTED STONE 10" 1'-2" SPLICE 30" LAP T/SLAB = -1' -0" 8" MIN. #4 @ 12" O.C. EACH WAY #4 DOWELS @ 12" O.C. WITH 16" LEGS FTG -SEE PLAN STEEL GRATING PROVIDE RECESS FOR GRATING, 2-SIDES2'-0" SQ 2" 2'-0" L3X3X1/4 W/ 3/8" DIA. HILTI KWIK BOLT, 2 3/4" EMBED @ 10" O.C. 10" 1'-0" COMPACTED FILL (2) #4 BOTTOM GRADE SIDEWALK -SEE CIVIL DWGS 4 1/2" 1' - 2" SLAB-ON-GRADE #4 DOWELS @ 18" O.C.12" 20" 8" 3' - 0" MIN. 9 1/2" COMPACTED FILLSEE PLAN SLAB-ON-GRADE GRADE SIDEWALK -SEE CIVIL DWGS 10" FOOTING -SEE PLAN PIER-SEE PLAN TIMBER COLUMN BY OTHERS -SEE PLAN 1/2" FIBER EXP. JOINT 1'-9"1'-9" (2) #4 BOTTOM MASONRY WALL -SEE PLAN SLAB-ON-GRADE COMPACTED FILL 1' - 8" 1' - 0" #4 @ 12" HORZ. #4 @ 32" O.C. VERT. W/ 6" HOOK 6"8"6" SEE PLAN 1/2" FIBER EXP. JOINT 2' - 2". 8" 1 1 SLAB-ON-GRADE OVER ENGINEERED FILL (3) #4 HORIZ. #4 @ 18" O.C. VERT. 11 1/4". 10" 1 1 SLAB-ON-GRADE OVER ENGINEERED FILL 2X6 WOOD PARTITION WALL @ SECT 13A AS PER PLAN (2) #4 BOTTOM @ SECT. 13A 4X6 5/8" DIA. x 7" LONG GALVANIZED HILTI KWIK BOLT III @ 32" O.C. 3 1/2" EMBEDMENT COUNTERSUNK INTO SILL BEAM 3" 3 1/2" (4) #4 BOTTOM MASONRY WALL -SEE PLAN SLAB-ON-GRADE COMPACTED FILL 3' - 0" 1' - 4" #4 @ 12" HORZ. #5 @ 8" O.C. VERT. W/ 12" HOOK 1' - 1"10"1' - 1" SEE PLAN 1/2" FIBER EXP. JOINT VARIES #4 @ 9" O.C. 2' - 0" 1' - 0" 3" 1' - 2" GRADE #4 @ 8" HORZ. #4 @ 16" O.C. VERT. W/ 12" HOOK (3) #4 MASONRY WALL - SEE PLAN PROPERTY LINE EX I S T I N G B U I L D I N G MATCH BOTTOM OF EXISTING FOOTING, V.I.F. SLAB-ON-GRADE 1/2" FIBER EXP. JOINT PROVIDE BOND BREAKER SPLICE 30" LAP SEE PLAN T/WALL = 0' -0" COMPACTED FILL GRADE SIDEWALK -SEE CIVIL DWGS SLAB-ON-GRADE#4 DOWELS @ 18" O.C. 12" 20" 8" www.kengsc.com Project number Date Drawn by Checked by SEAL: COPYRIGHT 2020 K.ENG LLC SHEET NUMBER: TITLE: FIRM ILLINOIS LICENSE NO. 184-004153 KDK KDK S4.0 SECTIONS 18-1015 232 E MAIN ST. ASPEN, CO CORE AND SHELL BUILDING 6-14-2018 3/4" = 1'-0"S4.0 1 SECTION 1/2" = 1'-0"S4.0 2 SECTION 1/2" = 1'-0"S4.0 3 SECTION 3/4" = 1'-0"S4.0 4 SLAB STEP 1/2" = 1'-0"S4.0 5 SECTION 1/2" = 1'-0"S4.0 6 SECTION 3/4" = 1'-0"S4.0 7 SECTION 1/2" = 1'-0"S4.0 9 NOT USED 3/4" = 1'-0"S4.0 10 SECTION 1/2" = 1'-0"S4.0 11 SECTION 1/2" = 1'-0"S4.0 12 SUMP PIT DETAIL AT ELEVATOR 3/4" = 1'-0"S4.0 8 SECTION 3/4" = 1'-0"S4.0 14 SECTION 1/2" = 1'-0"S4.0 15 SECTION 4, 4A 3/4" = 1'-0"S4.0 16 SLAB STEP 3/4" = 1'-0"S4.0 13 SLAB STEP 1/2" = 1'-0"S4.0 17 SECTION 1/2" = 1'-0"S4.0 18 SECTION 3/4" = 1'-0"S4.0 19 SECTION EXP 10-31-21 No.Description Date 1 PERMIT 9-25-2018 2 ISSUE FOR BID 11-28-2018 3 PERMIT CORRECTIONS 8-9-2019 4 PERMIT CORRECTION 12-18-2019 5 CONSTRUCTION 5-27-2020 7 FOUNDATION - TIMBER COOR. 8-7-2020 8 FOUNDATION - TIMBER FINAL 8-13-2020 11 CENTAUR FTG ELEV COOR. 8-25-2020 13 PERMIT REVISION 9-4-2020 14 WESTERN WOOD COORD.9-18-2020 16 CONSTRUCTION DOCUMENT REVISION 10-5-2020 17 CONSTRUCTION REVISIONS 10-15-2020 19 CONSTRUCTION REVISIONS 10-26-2020 FOOTING IS ECCENTRICALLY LOADED. PROVIDE CALCULATIONS INDICATING THIS HAS BEEN TAKEN INTO ACCOUNT FOOTING IS ECCENTRICALLY LOADED. PROVIDE CALCULATIONS INDICATING THIS HAS BEEN TAKEN INTO ACCOUNT FOOTING IS ECCENTRICALLY LOADED. PROVIDE CALCULATIONS INDICATING THIS HAS BEEN TAKEN INTO ACCOUNT TWO MATS OF REBAR ARE REQUIRED DUE TO WALL THICKNESS PER ACI 318-14 CHAPTER 11 REQUIREMENTS TWO MATS OF REBAR ARE REQUIRED DUE TO WALL THICKNESS PER ACI 318-14 CHAPTER 11 REQUIREMENTS 12/02/2020 SLAB-ON-GRADE COMPACTED FILL VERTICAL REINFORCING -SEE SCHEDULE FOOTING -SEE PLAN SE E P L A N CMU -SEE PLAN 5' - 0" 1' - 6 " #3 X 4 FT LONG @ 32" O.C. 3" #6 @ 12" O.C. TOP & BOTTOM 30 " L A P S P L I C E (9) #6 TOP & BOTTOM #4 @ 12" HORZ. #5 @ 8" O.C. VERT. W/ 12" HOOK 10" SLAB-ON-GRADE ELEV. VARIES -SEE PLAN COMPACTED FILL VERTICAL REINFORCING -SEE SCHEDULE FOOTING -SEE PLAN SE E P L A N 1' - 0" CMU -SEE PLAN 6' - 6" 1' - 0 " #3 @ 32" O.C. 3" #5 @ 10" O.C. 30 " L A P S P L I C E (8) #5 18"12" #4 @ 12" HORZ. #5 @ 8" O.C. VERT. W/ 12" HOOK 10" T/SLAB = 0' -0" EX I S T I N G B U I L D I N G 4' - 7 1 / 2 " OVERPOUR ADJACENT BOTTOM OF FOOTING POUR SEE 3/S4.0 SLAB-ON-GRADE PROPERTY LINE 1' - 6 " . REBAR IN SLAB PER 16/S4.3SLAB-ON-GRADE EX I S T I N G B U I L D I N G 2' - 6"2' - 8" 3' - 3 1 / 2 " 4' - 7 1 / 2 " SEE 3/S4.0 PROPERTY LINE 1' - 6 " . REBAR IN SLAB PER 16/S4.3 3' - 0 " SLAB-ON-GRADE COMPACTED FILL FOOTING -SEE PLAN SE E P L A N 5' - 0" 1' - 6 " #6 @ 12" O.C. TOP & BOTTOM (8) #5 TOP & BOTTOM 3" 5'-6"2'-0"2'-0"2'-0"4'-2" -2' - 0" SOG 0' - 0:" SOG -1' -0" SOG DR Y W E L L C.2 CMU CONC WALL SEE 3/S4.1 SIMILAR FOR BAR BEND 1' - 0 " B/FTG -13' -3" B/FTG -12' -3" B/FTG -11' -3" -2' - 8" SOG -1' - 0" T/PIER-1' -11 1/4" SOG B/FTG MATCH EXISTING DO NOT UNDERMINE CMU CMU WOOD WOOD COLUMN PIERCONC WALL CONC WALL CONC WALL BOTTOM REBAR 1'-0" 2'-0"2'-0"4'-0" 1 1 1/2 3'-6"2'-0"4'-0" CM U 2'-0" 2'-0" COMPACT ENGINEERED FILL PRIOR TO POURING UPPER FOOTING 1' - 0 " 1' - 0 " 1' - 0 " 1' - 0 " FTG ALONG COL LINE 10 FTG ALONG COL LINE 9 A C.2 D.4 E.8 F.8 6 1 / 2 " B/FTG -5' -2" B/FTG -7' -10" 1' - 0 " 1' - 0 " 4' - 1 0 " 11 1/2 B/FTG -5' -10" 3'-6" 1'-6"2'-0"1'-6" B/FTG -6' -10" 1' - 0 " 1' - 4 " (11) #4 TOP & BOTTOM SLAB-ON-GRADE COMPACTED FILL 5' - 0" 1' - 0 " #4 @ 8" HORZ. EACH FACE #4 @ 16" O.C. VERT. W/ 12" HOOK, EACH FACE 1' - 6 1/2"2' - 0"1' - 5 1/2" #4 @ 12”TOP & BOTTOM SIDEWALK -SEE CIVIL DWGS 6" 1/2" FIBER EXP. JOINT CLT WALL -BY OTHERS 4X6 SOUTHERN PINE 8" 9 1/2" 3/4" DIA. A36 THREADED ROD INSTALL W/ HILTI HY200 EPOXY AND 9" EMBEDMENT HOLD-DOWN BRACKET BY CLT PROVIDER SEE PLAN FOR LOCATIONS (2 THUS) 3 1 / 2 " 5/8" DIA. x 7" LONG GALVANIZED HILTI KWIK BOLT III @ 24" O.C. 3 1/2" EMBEDMENT COUNTERSUNK INTO SILL BEAM WALL PER 9/S4.0 PIER P4 1'-3"2'-0" 1'-2" 2'-1"1' - 7 1 / 8 " #5 DOWELS FOR CMU WALL INTO FOOTING #4 @ 8" HORIZ. #4 VERT AS SHOWN (12" TO 14" O.C.) T/CONC = 0' -0" T/CONC +0' -0" T/CONC +0' -8" WALL PER 1/S4.1 5" 5" 1' - 2 1 / 2 " 4 6" 8"1 1 SLAB-ON-GRADE OVER ENGINEERED FILL VA R I E S 8"1 1 SLAB-ON-GRADE OVER ENGINEERED FILL www.kengsc.com Project number Date Drawn by Checked by SEAL: COPYRIGHT 2018 K.ENG LLC SHEET NUMBER: TITLE: FIRM ILLINOIS LICENSE NO. 184-004153 KDK KDK S4.1 SECTIONS 18-1015 232 E MAIN ST. ASPEN, CO CORE AND SHELL BUILDING 6-14-2018 3/4" = 1'-0"S4.1 1 SECTION 3/4" = 1'-0"S4.1 2 SECTION 1/2" = 1'-0"S4.1 4 SECTION 1/2" = 1'-0"S4.1 3 SECTION 3/4" = 1'-0"S4.1 5 SECTION 3/16" = 1'-0"S4.1 6 ELEV VIEW SHEAR WALL ON COL LINE 7 3/16" = 1'-0"S4.1 7 ELEV VIEW WALLS ON COL LINE 9 AND 10 1/2" = 1'-0"S4.1 8 SECTION 3/4" = 1'-0"S4.1 9 PLAN VIEW OF FOUNDATION WALL EXP 10-31-21 3/4" = 1'-0"S4.1 10 SLAB STEP 3/4" = 1'-0"S4.1 11 SLAB STEP No.Description Date 1 PERMIT 9-25-2018 2 ISSUE FOR BID 11-28-2018 3 PERMIT CORRECTIONS 8-9-2019 4 PERMIT CORRECTION 12-18-2019 5 CONSTRUCTION 5-27-2020 7 FOUNDATION - TIMBER COOR. 8-7-2020 8 FOUNDATION - TIMBER FINAL 8-13-2020 11 CENTAUR FTG ELEV COOR. 8-25-2020 12 MODIF COORDINATION 9-2-2020 13 PERMIT REVISION 9-4-2020 14 WESTERN WOOD COORD.9-18-2020 17 CONSTRUCTION REVISIONS 10-15-2020 19 CONSTRUCTION REVISIONS 10-26-2020 12/02/2020 MASONRY WALL - SEE PLAN ROOF CLT PANEL (2) #5 CONT. 3/8" CONT. BENT PLATE W/ 5/8" DIA. HEADED ANCHOR BOLTS @ 32" O.C. (FOR LATERAL LOAD TRANSFER ONLY) GR O U T S O L I D 5" 1 1 / 2 " ANCHORAGE OF CLT TO PLATE BY WESTERN WOOD BOND BEAM DIM. TO BE APPROVED BY WESTERN WOOD T/MASONRY = +16 ' -0" 1 1/2" 5" 4" PROVIDE WEDGE WASHER BOLT IN BOTTOM OF 2" LONG VERT. SLOT 2X8 W/ 1/2" DIA. ANCHOR BOLTS @ 48" O.C. COUNTERSINK NUT 4" 3" MASONRY WALL -SEE PLAN BOND BEAM BOND BEAM W/(1) #4 CONT. DOUBLE TOP PLATE - SEE ARCH. DWGS W/ 1/2" X 8" LONG THREADED RODS @ 36" O.C. CLT PANEL L5X5X5/16 W/ 5/8" DIA. ANCHOR BOLTS @ 48" O.C. (FOR LATERAL LOAD TRANSFER ONLY) GR O U T S O L I D (2) #5 CONT. ANCHORAGE OF CLT TO ANGLE BY WESTERN WOOD DIM. TO BE APPROVED BY WESTERN WOOD 4"1" 3" ROD 5" BOLT IN BOTTOM OF 2" LONG VERT. SLOT T/CLT = +11' -0" MASONRY WALL -SEE PLAN BOND BEAM BOND BEAM W/(1) #4 CONT. DOUBLE TOP PLATE - SEE ARCH. DWGS W/ 1/2" X 8" LONG THREADED BOLTS @ 36" O.C. GR O U T S O L I D FINISH -SEE ARCH. DWGS CLT PANEL L5X5X3/8 W/ 5/8" DIA. ANCHOR BOLTS @ 24" O.C. (2) #5 CONT.ANCHORAGE OF CLT TO PLATE BY WESTERN WOOD DIM. TO BE APPROVED BY WESTERN WOOD 4"1" 1 1 / 2 " ROD 5" T/CLT = +11' -0" MASONRY WALL -SEE PLAN SLOPING ROOF CLT PANEL (2) #5 CONT. CONT. BENT PLATE 8"X4"X3/8" W/ 5/8" DIA. HEADED ANCHOR BOLTS @ 24" O.C. (FOR LATERAL LOAD TRANSFER ONLY) ROD 6" 5" ANCHORAGE OF CLT TO PLATE BY WESTERN WOOD T/MASONRY VARIES 2X10 W/ 1/2" DIA. ANCHOR BOLTS @ 48" O.C. COUNTERSINK NUT 4" 1" 1 1 / 2 " MASONRY WALL -SEE PLAN SLOPING ROOF CLT PANEL (2) #5 CONT. ON SLOPE ROD 6" 5" 1 1 / 2 " ANCHORAGE OF CLT TO PLATE BY WESTERN WOOD 3" SLOPING ROOF CLT PANEL BOLT IN BOTTOM OF 2" LONG VERT. SLOT 3"1" T/MASONRY VARIES 2X10 W/ 1/2" DIA. ANCHOR BOLTS @ 48" O.C. COUNTERSINK BOLT 4" 8" CONT. BENT PLATE 8"X4"X3/8" W/ 5/8" DIA. HEADED ANCHOR BOLTS @ 24" O.C. (FOR LATERAL LOAD TRANSFER ONLY) L5X5X5/16 W/ 5/8" DIA. ANCHOR BOLTS @ 24" O.C. (FOR LATERAL LOAD TRANSFER ONLY) 1"4" DIM. TO BE APPROVED BY WESTERN WOOD MASONRY WALL -SEE PLAN (2) #5 CONT. CONT. L7X4X3/8 LLV W/ 5/8" DIA. HEADED ANCHOR BOLTS @ 16" O.C. ANCHORAGE OF CLT TO ANGLE BY WESTERN WOOD DIM. TO BE APPROVED BY WESTERN WOOD 2" CLT PANEL 1" 1" 3" ROD 6" T/CLT = +11' -0" MASONRY WALL -SEE PLAN (2) #5 CONT. CONT. L7X4X3/8 LLV W/ 5/8" DIA. HEADED ANCHOR BOLTS @ 24" O.C. ANCHORAGE OF CLT TO PLATE BY WESTERN WOOD 2" CLT PANEL 1"3" ROD 6" DIM. TO BE APPROVED BY WESTERN WOOD T/CLT = +12' -0" MASONRY WALL -SEE PLAN CLT PANEL 3/8" CONT. BENT PLATE W/ 5/8" DIA. HEADED ANCHOR BOLTS @ 32" O.C. (FOR LATERAL LOAD TRANSFER ONLY) ROD 5" 5 1 / 2 " 2 1 / 2 " 5" 1 1 / 2 " ANCHORAGE OF CLT TO PLATE BY WESTERN WOOD 3X10 1 1/2" T/CLT = +12' -0" 4" 4" 3" 1/2" DIA. ANCHOR BOLTS @ 48" O.C. COUNTERSINK BOLT MASONRY WALL -SEE PLAN (2) #5 CONT. ANCHORAGE OF CLT TO ANGLE BY WESTERN WOOD 3" CLT PANEL DIM. TO BE APPROVED BY WESTERN WOOD T/CLT = +12' -0" BOLTS IN BOTTOM OF 2" LONG VERT. SLOT L5X5X5/16 W/ 5/8" DIA. ANCHOR BOLTS @ 48" O.C. (FOR LATERAL LOAD TRANSFER ONLY) 1"4" 6" MASONRY WALL -SEE PLAN ANCHORAGE OF CLT TO ANGLE BY WESTERN WOOD 3" CLT PANEL DIM. TO BE APPROVED BY WESTERN WOOD T/CLT = +12' -0" BOLTS IN BOTTOM OF 2" LONG VERT. SLOT L5X5X5/16 W/ 5/8" DIA. ANCHOR BOLTS @ 48" O.C. (FOR LATERAL LOAD TRANSFER ONLY) 1"4" 4" SO L I D GR O U T BOND BEAM (DOES NOT MATCH SOUTH WALL OF STAIRS) MASONRY WALL -SEE PLAN ANCHORAGE OF CLT TO ANGLE BY WESTERN WOOD 2" CLT PANEL DIM. TO BE APPROVED BY WESTERN WOOD T/CLT = +12' -0" L5X5X5/16 W/ 5/8" DIA. ANCHOR BOLTS @ 24" O.C. (FOR LATERAL LOAD TRANSFER ONLY) 1"4" 4" SO L I D GR O U T BOND BEAM MASONRY WALL -SEE PLAN CLT PANEL T/CLT = +12' -0" 1' - 2 1 / 2 " 6 7/8" 1/2"1/2" 1 1/2" 6" 1/ 2 " 3/ 8 " 1' - 2 1 / 2 " 5 5/8"3/8" 3" 9 5/8" 3/ 8 " 8 5/8" 1/2" EXP BOLT CENTERED IN PLATE 16" DEEP TIMBER BEAM BEAM BRACKET BRACKET ELEV. BRACKET PROFILE 1/4" PLATE 1/2" DIA. HOLE 1/4 1/4 1/4 1/ 2 " MASONRY WALL -SEE PLAN CLT PANEL T/CLT = +12' -0" SO L I D GR O U T BOND BEAM TIMBER BEAM 1 1/2"1'-0"1 1/2" 1 1 / 2 " 8" 8" 4 1 / 2 " BRACKET BY WESTERN WOOD BACK PLATE ELEVATION (6) 5/8" DIA. BOLTS MAX. ALLOWABLE REACTION = 16K MASONRY WALL -SEE PLAN CLT PANEL T/CLT = +12' -0" TIMBER BEAM 1 1/2"1'-0"1 1/2" 1 1 / 2 " 8" 4 1 / 2 " BRACKET BY WESTERN WOOD BACK PLATE ELEVATION (4) 5/8" DIA. BOLTS MAX. ALLOWABLE REACTION = 10.7K MASONRY WALL -SEE PLAN (2) #5 CONT. ANCHORAGE OF CLT TO ANGLE BY WESTERN WOOD 3" CLT PANEL DIM. TO BE APPROVED BY WESTERN WOOD T/CLT = +12' -0" BOLTS IN BOTTOM OF 2" LONG VERT. SLOT L5X5X5/16 W/ 5/8" DIA. ANCHOR BOLTS @ 24" O.C. (FOR LATERAL LOAD TRANSFER ONLY) 1"4" 6" L4X4X1/4 X 4" LONG W/ 1/2" DIA. HILTI HLC SLEEVE ANCHORS, 1 1/2" EMBED. PROVIDE (2) ANGLES EQUALLY SPACED PER WALL SECTION 3/16 3/16 LINTEL ELEVATOR SHAFT MASONRY WALL -SEE PLAN ANCHORAGE OF CLT TO ANGLE BY WESTERN WOOD CLT PANEL DIM. TO BE APPROVED BY WESTERN WOOD T/CLT = +12' -0" 1"4" L5X5X5/16 W/ 1/2" DIA. HILTI HLC SLEEVE ANCHORS, 1 1/2" EMBED. @ 16" O.C. 2" MASONRY WALL -SEE PLAN ROOF CLT PANEL ANCHORAGE OF CLT TO PLATE BY WESTERN WOOD3X10 W/ 1/2" DIA. ANCHOR BOLTS @ 32" O.C. COUNTERSINK NUT 4" MASONRY WALL - SEE PLAN ROOF CLT PANEL (2) #5 CONT. GR O U T S O L I D BOND BEAM T/MASONRY = +16 ' -0" 4" 1 1/2"1'-0"1 1/2" 1 1 / 2 " 8" 5" BRACKET BY WESTERN WOOD BACK PLATE ELEVATION (4) 5/8" DIA. HILTI KWIK BOLTS, 4" EMBED. 5" MAX. ALLOWABLE REACTION = 11K www.kengsc.com Project number Date Drawn by Checked by SEAL: COPYRIGHT 2018 K.ENG LLC SHEET NUMBER: TITLE: FIRM ILLINOIS LICENSE NO. 184-004153 KDK KDK S4.2 SECTIONS 18-1015 232 E MAIN ST. ASPEN, CO CORE AND SHELL BUILDING 6-14-2018 EXP 10-31-21 3/4" = 1'-0"S4.2 1 SECTION 3/4" = 1'-0"S4.2 4 SECTION 3/4" = 1'-0"S4.2 7 SECTION 3/4" = 1'-0"S4.2 2 SECTION 3/4" = 1'-0"S4.2 3 SECTION 3/4" = 1'-0"S4.2 5 SECTION 3/4" = 1'-0"S4.2 6 SECTION 3/4" = 1'-0"S4.2 8 SECTION 3/4" = 1'-0"S4.2 9 SECTION 3/4" = 1'-0"S4.2 10 SECTION 3/4" = 1'-0"S4.2 11 SECTION 3/4" = 1'-0"S4.2 12 SECTION 3/4" = 1'-0"S4.2 13 SECTION 3/4" = 1'-0"S4.2 14 SECTION 3/4" = 1'-0"S4.2 15 SECTION 3/4" = 1'-0"S4.2 16 SECTION 3/4" = 1'-0"S4.2 17 SECTION 3/4" = 1'-0"S4.2 18 SECTION 3/4" = 1'-0"S4.2 19 SECTION No.Description Date 1 PERMIT 9-25-2018 2 ISSUE FOR BID 11-28-2018 3 PERMIT CORRECTIONS 8-9-2019 4 PERMIT CORRECTION 12-18-2019 5 CONSTRUCTION 5-27-2020 14 WESTERN WOOD COORD.9-18-2020 12/02/2020 MASONRY WALL -SEE PLAN 3" SLOPING ROOF CLT PANEL BOLT IN BOTTOM OF 2" LONG VERT. SLOT L5X5X5/16 W/ 5/8" DIA. ANCHOR BOLTS @ 16" O.C. (FOR LATERAL LOAD TRANSFER ONLY) 1"4" DIM. TO BE APPROVED BY WESTERN WOOD ANCHORAGE OF CLT TO ANGLE BY WESTERN WOOD 6" MASONRY WALL -SEE PLAN SLOPING ROOF CLT PANEL BOLT IN BOTTOM OF 2" LONG VERT. SLOT L5X5X5/16 W/ 1/2" DIA. HILTI HLC SLEEVE ANCHORS 1 1/2" EMBED. @ 24" O.C. (FOR LATERAL LOAD TRANSFER ONLY) 1"4" DIM. TO BE APPROVED BY WESTERN WOOD ANCHORAGE OF CLT TO ANGLE BY WESTERN WOOD 3" BOND BEAM B/BOND BEAM = +23' -4" GR O U T S O L I D MASONRY WALL - SEE PLAN ROOF CLT PANEL 3/8" CONT. BENT PLATE W/ 5/8" DIA. HEADED ANCHOR BOLTS @ 16" O.C. 6" 1 1 / 2 " ANCHORAGE OF CLT TO PLATE BY WESTERN WOOD DIM. TO BE APPROVED BY WESTERN WOOD PROVIDE WEDGE WASHER 6" 4" MASONRY WALL -SEE PLAN SLOPING ROOF CLT PANEL BOND BEAM 1 1/2"1'-0"1 1/2" BRACKET BY WESTERN WOOD BACK PLATE ELEVATION(4) 5/8" DIA. HILTI KWIK BOLTS, 4" EMBED. MAX. ALLOWABLE REACTION = 11K 8" GR O U T S O L I D 8" 1 1 / 2 " MASONRY WALL - SEE PLAN 3/8" CONT. BENT PLATES W/ 5/8" DIA. HEADED ANCHOR BOLTS @ 16" O.C. DIM. TO BE APPROVED BY WESTERN WOOD PROVIDE WEDGE WASHERROOF CLT PANEL (2) #5 CONT. 1 1 / 2 " ANCHORAGE OF CLT TO PLATE BY WESTERN WOOD1 1/2" 5" 4" 6"1 1 / 2 " 6" 4" MASONRY WALL - SEE PLAN 3/8" CONT. BENT PLATES W/ 5/8" DIA. HEADED ANCHOR BOLTS @ 16" O.C. DIM. TO BE APPROVED BY WESTERN WOOD PROVIDE WEDGE WASHER ROOF CLT PANEL 2 1 / 2 " ANCHORAGE OF CLT TO PLATE BY WESTERN WOOD1 1/2" 5" 4" 1 1 / 2 " 6" 4" BOND BEAM SO L I D GR O U T 12 " M I N . 1 1 / 2 " 8" 8" 8" 8" 1 1 / 2 " BACK PLATE ELEVATION Tmin = 3/8" MAX. ALLOWABLE REACTION = 4K 8"4"EDGE OF CMU (8) 5/8" DIA. HILTI KWIK BOLTS, 4" EMBED. DO NOT LOCATE IN MORTAR JOINT MASONRY WALL -SEE PLAN, WALL IS GROUTED SOLID FOR 2' -0" WIDTH AT BEAM AS PER WALL SCHEDULE BOND BEAM GR O U T S O L I D CLT PANEL T/CLT = +11' -0" TIMBER BEAM BRACKET BY WESTERN WOOD 1' - 4 " C.2 1"8"6" 2 1 / 2 " 8" 8" 8" 8" www.kengsc.com Project number Date Drawn by Checked by SEAL: COPYRIGHT 2018 K.ENG LLC SHEET NUMBER: TITLE: FIRM ILLINOIS LICENSE NO. 184-004153 KDK KDK S4.3 SECTIONS 18-1015 232 E MAIN ST. ASPEN, CO CORE AND SHELL BUILDING 6-14-2018 EXP 10-31-21 3/4" = 1'-0"S4.3 1 SECTION 3/4" = 1'-0"S4.3 2 SECTION 3/4" = 1'-0"S4.3 3 SECTION 3/4" = 1'-0"S4.3 4 SECTION 3/4" = 1'-0"S4.3 5 SECTION 3/4" = 1'-0"S4.3 6 SECTION 3/4" = 1'-0"S4.3 7 SECTION No.Description Date 1 PERMIT 9-25-2018 2 ISSUE FOR BID 11-28-2018 3 PERMIT CORRECTIONS 8-9-2019 4 PERMIT CORRECTION 12-18-2019 5 CONSTRUCTION 5-27-2020 14 WESTERN WOOD COORD.9-18-2020 12/02/2020