HomeMy WebLinkAboutFile Documents.1322 Snowbunny Ln.0035-2021-BCHO (9)PFS APPROVED FOR NATURAL GAS OR PROPANE GAS
Z21.50 - 2014
WARNING: THIS FIREPLACE MUST
BE INSTALLED USING AN APPROVED
POWER VENT FAN. SEE "INSTALLING
CHIMNEY/VENT SYSTEMS" SECTION
OF THIS MANUAL FOR APPROVED
FAN MODELS AND SPECIFICATIONS.
MODEL LFP9618 POWER VENTED TOP VENT GAS FIREPLACE
1/19
06/24/2021
TABLE OF CONTENTS
Section
Layout Options ............................................................................................................. 2
of Parts ..................................................................................................... 3
Building Codes and Safety Standards ..........................................................................
Piping and Gas Pressure Requirements .......................................................................
Installation Instructions ...............................................................................................6-9
Lighting Instructions .................................................................................................14-15
Trouble Shooting .......................................................................................................16-17
Replacement Parts ........................................................................................................ 18
2
INSIDE
ROOMFLUSH MOUNT CHASE
INSTALLATION OPTIONS
Figure 2.1
Glass Installation / Flame Stabilizer Installation...................................................10-11
Maintenance Instructions/Wiring Diagram............................................................. 113
Operating Guidelines ................................................................................................. 12
06/24/2021
INTERIOR VIEW
Left Outside
Air Control
Damper Control
Lever
Pilot Assy/
Flame Sensor
Right Outside
Air Control
On/Off Switch
LEFT RIGHT
Valve Access Door
OUTSIDE AIR CONNECTIONS
/)3&2032N(N7/2&A7I2N6
06/24/2021
BUILDING CODES AND SAFETY STANDARDS
NOTE: INSTALLATION AND REPAIR SHOULD BE DONE B@ A 8UALIFIED SER=ICE
PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST
ANNUALL@ B@ A PROFESSIONAL SER=ICE PERSON. MORE FRE8UENT CLEANING
MA@ BE RE8UIRED DUE TO E?CESSI=E LINT FROM CARPETING BEDDING
MATERIAL ETC. IT IS IMPERATI=E THAT THE UNITS CONTROL COMPARTMENT
BURNERS AND CIRCULATING AIR PASSAGE-WA@S BE 2EPT CLEAN TO PRO=IDE
ADE8UATE COMBUSTION AND =ENTILATION AIR.
CLEARANCES REQUIRED
MINIMUM CLEARANCES FOR THE FIREBO? ARE!
1/2" ON THE SIDES AND BAC2 AND 0 AT THE BOTTOM. TOP CLEARANCE IS 3".
NOTE: PRO=IDE ADE8UATE CLEARANCES AROUND AIR OPENINGS INTO THE
COMBUSTION CHAMBER.
NOTE: ADE8UATE ACCESSIBILIT@ CLEARANCES FOR SER=ICING AND PROPER
OPERATION MUST BE PRO=IDED IN ACCORDANCE WITH ANSI A21.50-2014.
The design of this FIREPLACE has been tested and is listed ^ith PFS CORPORATION
in accordance ^ith THE AMERICAN NATIONAL STANDARDS INSTITUTE ·
ANSI A21.50-2014.
This manual ser]es only as a basic guideline for installation and use of this
and gas piping. The complete installation must be in accordance ^ith local codes and
ordinances or in the absence of local codes ^ith the American National Standards
Institute National Fuel Gas Code A223.1 latest edition.
GENERAL INFORMATION
MODEL LFP9618 IS A TOP =ENTED GAS FIREPLACE. IT IS DESIGNED TO BURN B@
DRAWING COMBUSTION AIR FROM THE OUTSIDE AIR 2IT THAT ATTACHES TO THE SIDE
SIDES OF THE FIREPLACE.
THE E?HAUST FLUE GASES ARE TO BE =ENTED THROUGH THE TOP-=ENT USING
10" B-T@PE GAS =ENT PIPE
ASSISTED BY AN APPROVED POWER VENT E;HAUST
FAN.
THE CONTROL S@STEM IS A 3= SPAR2 TO PILOT T@PE THAT INCLUDES A
ON-OFF SHUTOFF =AL=E A GAS CONTROL =AL=E A SPAR2 TO PILOT LIGHT
ASSEMBL@ AND ON-OFF ROC2ER SWITCH.
WARNING: THIS UNIT IS NOT FOR USE WITH SOLID FUEL.
06/24/2021
All gas piping must be installed to comply with local codes, or, in the absence of local
codes, with the latest edition of the National Fuel Gas Code ANSI Z223.1.
Unions in gas lines shall be of ground joint type. Compounds used on threaded joints of
gas piping must be resistant to the action of liquefied petroleum gas. Gas piping must be
of sufficient size to provide a minimum natural gas pressure at the appliance of 7" water
column or 11" for L.P. gases for the purpose of input adjustment. The maximum inlet gas
pressure to the unit must not exceed 10" for natural gas, and 13" for L.P. gases. If this
unit is to be supplied with L.P. gas (bottled propane) the tank or bottle supplying the gas
must have a regulator that reduces the gas pressure to between 11 and 13 inches water
column. The control will not operate with gas line pressure directly from the tank and may
leak gas due to this excessive pressure.
DANGER: OPERATION OF THIS UNIT ON L.P. GAS WITHOUT AN APPROVED
REGULATOR AT THE SUPPLY CONTAINER WILL LEAD TO GAS LEAKS AT THE
CONTROL WITH POSSIBLE FIRE OR EXPLOSION.
Include a manual shut-off valve and union in the line so the control or heater may be
disconnected for servicing. Include a drip leg and a plugged 1/8" N.P.T. tapping into the
line also. The tapping must be accessible for the test gauge connection immediately
upstream of the gas supply connection to the unit. Use a soap and water solution or
liquid gas leak detector to coat each joint in the piping system and look for bubbles
which indicate gas leaks. Repair all gas leaks.
CAUTION: THE APPLIANCE AND ITS APPLIANCE MAIN GAS VALVE MUST
BE DISCONNECTED FROM THE GAS SUPPLY PIPING SYSTEM DURING ANY
PRESSURE TESTING OF THAT SYSTEM AT TEST PRESSURES IN EXCESS OF
1/2 PSI (3.5 KPA).
THE APPLIANCE MUST BE ISOLATED FROM THE GAS SUPPLY PIPING SYSTEM BY
CLOSING THE EQUIPMENT SHUTOFF VALVE DURING ANY PRESSURE TESTING OF
THE GAS SUPPLY PIPING SYSTEM AT TEST PRESSURES EQUAL TO OR LESS THAN
1/2 PSI (3.5 KPA).
DANGER: DO NOT USE CANDLES, MATCHES OR OTHER IGNITION SOURCES WHEN
CHECKING FOR LEAKS. FUEL GASES ARE VERY FLAMMABLE AND IN CERTAIN
CONCENTRATIONS, EXPLOSIVE. CHECKING FOR LEAKS WITH AN OPEN FLAME MAY
LEAD TO FIRE OR EXPLOSION.
GAS PIPING AND GAS PRESSURE REQUIREMENTS
5 06/24/2021
INSTALLATION INSTRUCTIONS
In planning the installation for the it is necessary to determine ^here the
unit is to be installed the routing of the B-type ]ent system and ^hether optional
accessories are to be used gas supply piping should also be planned.
The can be mounted on any of the follo^ing surfaces!
1. A combustible surface.
2. A raised ^ooden platform.
3. Four 4 corner supports.
E_ample! four 4 concrete masonry blocRs. These supports must be positioned so
they contact all four corner edges on the bottom of the unit.
If the is installed directly on carpeting tile or other combustible material
other than ^ood the appliance shall be installed on a metal or ^ood panel
e_tending the full ^idth and depth of the unit.
Fireplace framing can be built before or after the is set in place. Framing
should be positioned to accommodate ^all co]ering and facing material.
The framing should be constructed of 2 _ 4 lumber or hea]ier. The framing
headers may rest on the standoffs. Refer to Figure .1 for and
framing reference dimensions.
CAUTION: VERIFY FIREPLACE DIMENSIONS, FRAMING METHODS AND WALL
COVERING DETAILS BEFORE FRAMING CONSTRUCTION BEGINS.
Determine the e_act position of the so that the ]ent run can be planned.
Figure 2.1 sho^s possible locations for the inside of a room mount
in a chase. Using a le]el maRe sure the ILUHSODFH LV SURSHUO\ positioned and
squared.
WARNING: DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE
LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.
CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON
OR NEAR THE APPLIANCE.
6
MRGHO LFP9618 wLWK WKH XVH RI WKH OXWVLGH ALU .LW FDQ EH LQVWDOOHG LQ D EHGURRP
LQ WKH UQLWHG SWDWHV wKLFK KDV D WRWDO YROXPH RI XQFRQILQHG VSDFH DSSURSULDWH WR
WKH SDUWLFXODU LQVWDOODWLRQ. RHIHU WR WKH NDWLRQDO FXHO GDV CRGH ANSI =.1/NFPA
FXUUHQW HGLWLRQ WKH UQLIRUP MHFKDQLFDO CRGH FXUUHQW HGLWLRQ DQG LRFDO
BXLOGLQJ OIILFLDOV IRU WKH RSWLRQV DOORwHG LQ REWDLQLQJ DQ HIIHFWLYH EHGURRP YROXPH
RI XQFRQILQHG VSDFH.
06/24/2021
Installing Chimney/Vent System
MINIMUM FRAMING DIMENSIONS PRIOR TO POSITIONING UNIT
FINISHED FRAMING DIMENSIONS WITH UNIT IN POSITION
NOTE: DIMENSIONS PRIOR TO POSITIONING FIREPLACE ALLOWS
CLEARANCE FOR OUTSIDE AIR COLLARS AS WELL AS FIREPLACE
HEADER TO BE NAILED AT CORRECT HEIGHT AFTER BOX HAS
BEEN SET.
11”TOP
VIEW
FIREPLACE IS
POSITIONED
MINIMUM
FRAMING
DIMENSIONS
52 1/2"
52"
30 1/2"
76 1/2"
INSTALLED AFTER
INSTALLED AFTER
FIREPLACE IS
POSITIONED
24”
32”
52”
Figure
18”
48 11/16”
4 1/8”
29”
2 1/2”
6 1/2”
23 1/2”
4”
7”
111”W X 52”H X 24” D
16”W X 32”H X 24”D
A
B
C
D
MINI080 FRAMING DIMENSIONS LFP
LFP 18
A "
B "
C 6"
D 3/4"
Model LFP9618 LV approved to be used with 1" B-Type Gas Vent. TKH FLUHSODFH PXVW EH LQVWDOOHG wLWK DQ EQHUYH[
MRGHO RS 1 E[KDXVW FDQ PDS1 RU ADC1 DUDIW SwLWFK WKDW LV FRQQHFWHG WR WKLV FLUHSODFH.
WARNING: TKLV FLUHSODFH PXVW QRW EH LQVWDOOHG wLWKRXW E[KDXVW FDQ GROGHQ BORXQW IQF. FDQ VXSSO\ WKH EQHUYH[
SURGXFWV RU WKH\ FDQ EH SXUFKDVHG WKURXJK D WKLUG SDUW\ VXSSOLHU.
WARNING: A PURYHQ DUDIW SwLWFK PXVW EH LQVWDOOHG wLWK WKH E[KDXVW FDQ DQG FRQQHFWHG WR WKLV FLUHSODFH. A
PURYHQ DUDIW SwLWFK wLOO SUHYHQW WKLV ILUHSODFH IURP RSHUDWLQJ LI WKH E[KDXVW FDQ LV QRW SURYLGLQJ SURSHU Hvacuation RI
IOXH JDVHV.
Note: Detailed instructions for Enervex Exhaust Fan, Power Draft Switch installation is included in the
Enervex Products.
06/24/2021
/)3A33R29('9(N7&2N)IG8RA7I2N6
T K H F R O O R w L Q J R H T X L U H P H Q W s M X V W B H M H W :
IF YOUR DESIRED INSTALLATION DOES NOT MEET THE ABOVE RE4UIREMENTS CONTACT
GOLDEN BLOUNT INC. TO VERIFY IF DESIRED INSTALLATION CAN BE CONGIFURED WITH
OTHER APPROVED POWER VENT E;HAUST FAN. 18811
WARNING:7KLVJDVDSSOLDQFHPXVWQRWEHFRQQHFWHGWRDFKLPQH\IOXHVHUYLQJDVHSDUDWH
VROLGIXHOEXUQLQJDSSOLDQFH
NRWH:DGUDIWKRRGLVLQVWDOOHGDQGLVLQWKHVDPHDWPRVSKHULFSUHVVXUH]RQHDVWKHFRPEXVWLRQDLU
LQOHWWRWKHDSSOLDQFHDQGLVORFDWHGVRWKDWWKHUHOLHIRSHQLQJLVDFFHVVLEOHIRUFKHFNLQJYHQW
RSHUDWLRQ
Minimum Vent Length ---------5'
Maximum Vertical Run --------50'
Maximum Horizontal Run -----50'
Maximum 45 Deg. Elbows ----4 ea.
Maximum 90 Deg. Elbow ------3 ea.
06/24/2021
Installing Outside Air Kit
Model LFP9618 LV supplied ^ith the component parts for outside combustion ^ith the e_ception of the4"duct. It is recommended that the outsid e air system be used ^hene]er possible. Connect 4" Class-1
Fle_ duct or Metal =ent to duct collarV on side of ILUHER[ UXQ GXFW WR IUHVK DLU VRXUFH DQG WHUPLQDWH XVLQJ GXFW
termination capV. The Outside air can be opened by pulling control Rnob to^ard front of ILUHSODFH DQG
closed by pushing to^ards rear Refer to .1.
CONTROL
2NOB
DUCT
TERMINATION
LEFT SIDE LFP4218
LEFT AND RIGHT
LFP6018
RAIN CAP
CAUL2ING
WALL
OUTER
CASING
DUCT
COLLAR
TWO
SUPPLIED
Figure 9.1 Connecting the Gas Line
Finishing the Wall
Finish the ^all ^ith the material
of your choice. Do not install a
combustible mantle or other
combustible proQection abo]e the
opening unless it is a
minimum of 12 inches abo]e top
of opening. Figure 9.
CAUTION: All Qoints bet^een the ^all and the surround Top and
Sides can only be sealed ^ith non-combustible material. Only non-combustible
material can be applied as facing to the surround. Figure 9.)
Hearth Extension
A Hearth E_tension may be installed. But it is not required for ]ented gas
STUD
2?4
HEADER
FINISHED
WALL
NON-COMBUSTIBLE
SEAL 1OINT
MANTLE
12" MIN
TOP OF
OPENING
Figure
Consult local building codes before gas line installation. This gas fireplace is designed
to accept a 1/2" supply line. Have the gas line installed by a qualified service person in
accordance with all building codes. Install gas line to fireplace on the right side
attaching gas line to the gas flex line inside the control box accessed by opening the
control box door.
06/24/2021
Figure 10.1
10
GLASS INSTALLATION (optional)
1.MODEL LFP9618 can be used with approved Fireglass to enhance the overall appearance.
2. Fill the burner tray below and up to the top of the burner ports. Do not cover burner ports.
3. Distribute additional glass around front, sides and rear of burner tray, covering floor area.
(Figures 10.1-10.2)
GLASS INSTALLATION CONT.
Figure 10.2
06/24/2021
11
GLASS FLAME STABILIZER INSTALLATION
ÓÖ ALL LFP MODELS ARE SUPPLIED WITH A GLASS FLAME STABILIZER THAT HELPS BURNER
FLAME MAINTAIN A VERTICAL POSITION.
ÒÖ LOCATE GLASS FLAME STABILIZER CLIPS AND INSERT GLASS FLAME STABILIZER INTO
THEM. CENTER GLASS FLAME STABILIZER SO THAT THERE IS SAME CLEARANCE ON LEFT
AND RIGHT SIDES.
3. GLASS FLAME STABILIZER SHOULD BE SEATED AGAINST FIREPLACE FLOOR AS SHOWN
06/24/2021
12
Upon completing the gas line connection, a small amount of air will be in the lines.
When lighting the pilot light, it will take a few minutes for the lines to purge
themselves of this air. Once the purging is complete, the pilot and burner will light and
operate as indicated in the instruction manual. Subsequent lighting of the appliance
will not require such purging.
WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS
OF HIGH SURFACE TEMPERATURE AND SHOULD STAY AWAY TO AVOID
BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CAREFULLY
SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.
IMPORTANT: TURN OFF GAS BEFORE SERVICING APPLIANCE. IT IS RECOMMENDED
THAT A COMPETENT SERVICE TECHNICIAN PERFORM THESE CHECKUPS AT
THE BEGINNING OF EACH HEATING SEASON.
WARNING: THE FLOW OF COMBUSTION AND VENTILATION AIR MUST NOT
BE OBSTRUCTED.
When lit for the time, the appliance
will emit a slight odor for an hour or two.
This is due to paint and lubricants used
in the manufacturing process. The main
burner characteristics are steady,
not lifting or Typically, the top
1/4 inch of the sensor should be
engulfed in the pilot A periodic
check of these characteristics is
necessary (Figure 12.1).
Figure
OPERATING GUIDELINES
Flame
Sensor
MAINTENANCE INSTRUCTIONS
IMPORTANT: THE APPLIANCE AREA MUST BE KEPT CLEAR AND FREE FROM
COMBUSTIBLE MATERIALS, GASOLINE AND OTHER FLAMMABLE VAPORS AND
LIQUIDS.
Visually inspect pilot periodically. Brush or blow away any dust or linen accumulations.
If pilot is plugged, disassembly may be required to remove any foreign material
from or tubing.
service technician or Venting system should be periodically examined by a
agency to ensure proper air
06/24/2021
13
WIRING DIAGRAM
06/24/2021
14
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: IF @OU DO NOT FOLLOW THESE INSTRUCTIONS E?ACTL@
A FIRE OR E?PLOSION MA@ RESULT CAUSING PROPERT@ DAMAGE
PERSONAL IN1UR@ OR LOSS OF LIFE.
A. This appliance is equipped ^ith an ignition de]ice ^hich automatically lights the
pilot. Do not light pilot by hand.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell
ne_t to the because some gas is hea]ier than air and ^ill settle on the
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance
Do not touch any electric s^itch!
Do not use any phone in your building.
Immediately call your gas supplier from a neighbor»s phone. Follo^ the gas
supplier»s instructions
C. Do not use this appliance if any part has been under ^ater. Immediately call a
ser]ice technician to inspect the appliance and to replace any part of
the gas control system ^hich has been under ^ater.
LIGHTING INSTRUCTIONS ELEC. SPARK TO PILOT
NOTE: DAMPER CONTROL LEVER MUST
BE IN THE “OPEN” POSITION TO IGNITE.
GAS VALVE
AQ DSSURYHG PRwHU VHQW FDQ PXVW EH LQVWDOOHG SULRU WR RSHUDWLQJ WKLV FLUHSODFH. SHH
SDJH 8 RI WKLV PDQXDO IRU IDQ LQIRUPDWLRQ.
D.
1.“STOP” Read the safety information
above.
2.After installing Enervex RS-14 Power
Vent and Proven Draft Switch you can
proceed with lighting of this Fireplace
3.Set the switch to “OFF”.
4.Remove batteries from battery pack.
5. This appliance is equipped with an
ignition device which automatically
lights the burner. Do not try to light the
burner by hand.
6.Wait (5) minutes to clear out any gas.
Then smell for gas, including near the
floor. If you smell gas, STOP! Follow
“B” in the safety information above. If
you don’t smell gas, go to next step.
7.Install (2) D batteries in battery pack.
8.Turn ON/OFF rocker switch to " ON".
9.If the appliance will not operate, follow
the instructions “To turn Off Gas To
Appliance” and call your service
technician or gas supplier.
NOTE: THIS FIREPLACE CAN ALSO BE
SERVICED WITH 120V JUNCTION BOX
AND 3-VOLT TRANSFORMER WHICH
CAN BE USED TO PROVIDE POWER IF
DESIRED (PART# JB-3V).
06/24/2021
15
TO TURN OFF GAS TO APPLIANCE
1. Turn ON/OFF rocRer s^itch to ¸OFF¹
2. Remo]e batteries from appliance if ser]ice is to be performed.
LPG (PROPANE) WARNING
THE FOLLOWING WARNING APPLIES TO INSTALLATIONS USING L.P. PROPANE GAS!
WARNING! To a]oid possible inQury and e_plosion please read and follo^ these precautions
and all instructions of this appliance before operating. This appliance uses L.P. Propane
gas ^hich is hea]ier than air and ^ill remain at the le]el is there is a leaR. Before lighting
smell at le]el and/or use other means such as using a soap solution on all piping and
connections using a gas detector etc. to checR for gas leaRs. NOTE! L.P. Propane gas can
become odorless and CANNOT al^ays be detected by smell. If you smell gas detect a gas leaR or
suspect that a gas leaR e_ists follo^ these rules!
1. Get all people out of building.
2. DO NOT light matches. DO NOT turn electric lights or s^itches on or off in area. DO NOT use
an electric fan to remo]e gas from area. DO NOT use a telephone inside of building.
3. Shut off gas at L.P. tanR outside of building.
4. Telephone gas company and department. AsR instructions. Before hanging up gi]e your
name address and phone number. DO NOT go bacR into building.
If your L.P. tanR runs out of fuel turn off gas at the appliance. After L.P. tanR is appliance
TO TURN OFF GAS TO APPLIANCE
must be re-lit according to manufacturer»s instructions. If The gas control has been e_posed to
WATER in any ^ay DO NOT try to use it. It must be replaced. DO NOT attempt repair on gas
control or appliance.
Tampering is DANGEROUS and ]oids all ^arranties. Any component that is found to be faulty
must be replaced ^ith an appro]ed component.
IMPORTANT: Always keep the appliance area clear and free from combustible materials,
gasoline and other flammable vapors and liquids.
Never obstruct the flow of combustion and ventilation air. Keep the front of the appliance
clear of all obstacles and materials.
To obtain proper operation, it is imperative that the pilot and main burner flame
characteristics are steady, not lifting or floating. Typically the top 1/4 Inch of the flame
sensor should be engulfed in the pilot flame. (Figure 12.1)
06/24/2021
16
Enervex Fan not operating
and connecting Draft
Switch to operate
Fireplace.
9.Check to see if Enervex
Fan is running and Draft
Switch is closing Fireplace
circuit.
9.
13
06/24/2021
17 06/24/2021
REPLACEMENT PARTS
THE FOLLOWING REPLACEMENT PARTS ARE AVAILABLE FROM YOUR GOLDEN BLOUNT DEALER
1
2
3 6
10
11 12
16
15
4
14
13
18
7 8
9
06/24/2021
19