HomeMy WebLinkAboutFile Documents.1322 Snowbunny Ln.0035-2021-BCHO (9)PFS APPROVED FOR NATURAL GAS OR PROPANE GAS Z21.50 - 2014 WARNING: THIS FIREPLACE MUST BE INSTALLED USING AN APPROVED POWER VENT FAN. SEE "INSTALLING CHIMNEY/VENT SYSTEMS" SECTION OF THIS MANUAL FOR APPROVED FAN MODELS AND SPECIFICATIONS. MODEL LFP9618 POWER VENTED TOP VENT GAS FIREPLACE 1/19 06/24/2021 TABLE OF CONTENTS Section Layout Options ............................................................................................................. 2 of Parts ..................................................................................................... 3 Building Codes and Safety Standards ..........................................................................  Piping and Gas Pressure Requirements .......................................................................  Installation Instructions ...............................................................................................6-9 Lighting Instructions .................................................................................................14-15 Trouble Shooting .......................................................................................................16-17 Replacement Parts ........................................................................................................ 18 2 INSIDE ROOMFLUSH MOUNT CHASE INSTALLATION OPTIONS Figure 2.1 Glass Installation / Flame Stabilizer Installation...................................................10-11 Maintenance Instructions/Wiring Diagram............................................................. 113 Operating Guidelines ................................................................................................. 12 06/24/2021 INTERIOR VIEW Left Outside Air Control Damper Control Lever Pilot Assy/ Flame Sensor Right Outside Air Control On/Off Switch LEFT RIGHT  Valve Access Door OUTSIDE AIR CONNECTIONS /)3&2032N(N7/2&A7I2N6 06/24/2021 BUILDING CODES AND SAFETY STANDARDS  NOTE: INSTALLATION AND REPAIR SHOULD BE DONE B@ A 8UALIFIED SER=ICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALL@ B@ A PROFESSIONAL SER=ICE PERSON. MORE FRE8UENT CLEANING MA@ BE RE8UIRED DUE TO E?CESSI=E LINT FROM CARPETING BEDDING MATERIAL ETC. IT IS IMPERATI=E THAT THE UNITS CONTROL COMPARTMENT BURNERS AND CIRCULATING AIR PASSAGE-WA@S BE 2EPT CLEAN TO PRO=IDE ADE8UATE COMBUSTION AND =ENTILATION AIR. CLEARANCES REQUIRED MINIMUM CLEARANCES FOR THE FIREBO? ARE! 1/2" ON THE SIDES AND BAC2 AND 0 AT THE BOTTOM. TOP CLEARANCE IS 3". NOTE: PRO=IDE ADE8UATE CLEARANCES AROUND AIR OPENINGS INTO THE COMBUSTION CHAMBER. NOTE: ADE8UATE ACCESSIBILIT@ CLEARANCES FOR SER=ICING AND PROPER OPERATION MUST BE PRO=IDED IN ACCORDANCE WITH ANSI A21.50-2014. The design of this FIREPLACE has been tested and is listed ^ith PFS CORPORATION in accordance ^ith THE AMERICAN NATIONAL STANDARDS INSTITUTE · ANSI A21.50-2014. This manual ser]es only as a basic guideline for installation and use of this and gas piping. The complete installation must be in accordance ^ith local codes and ordinances or in the absence of local codes ^ith the American National Standards Institute National Fuel Gas Code A223.1 latest edition. GENERAL INFORMATION MODEL LFP9618 IS A TOP =ENTED GAS FIREPLACE. IT IS DESIGNED TO BURN B@ DRAWING COMBUSTION AIR FROM THE OUTSIDE AIR 2IT THAT ATTACHES TO THE SIDE SIDES OF THE FIREPLACE. THE E?HAUST FLUE GASES ARE TO BE =ENTED THROUGH THE TOP-=ENT USING 10" B-T@PE GAS =ENT PIPE ASSISTED BY AN APPROVED POWER VENT E;HAUST FAN. THE CONTROL S@STEM IS A 3= SPAR2 TO PILOT T@PE THAT INCLUDES A ON-OFF SHUTOFF =AL=E A GAS CONTROL =AL=E A SPAR2 TO PILOT LIGHT ASSEMBL@ AND ON-OFF ROC2ER SWITCH. WARNING: THIS UNIT IS NOT FOR USE WITH SOLID FUEL. 06/24/2021 All gas piping must be installed to comply with local codes, or, in the absence of local codes, with the latest edition of the National Fuel Gas Code ANSI Z223.1. Unions in gas lines shall be of ground joint type. Compounds used on threaded joints of gas piping must be resistant to the action of liquefied petroleum gas. Gas piping must be of sufficient size to provide a minimum natural gas pressure at the appliance of 7" water column or 11" for L.P. gases for the purpose of input adjustment. The maximum inlet gas pressure to the unit must not exceed 10" for natural gas, and 13" for L.P. gases. If this unit is to be supplied with L.P. gas (bottled propane) the tank or bottle supplying the gas must have a regulator that reduces the gas pressure to between 11 and 13 inches water column. The control will not operate with gas line pressure directly from the tank and may leak gas due to this excessive pressure. DANGER: OPERATION OF THIS UNIT ON L.P. GAS WITHOUT AN APPROVED REGULATOR AT THE SUPPLY CONTAINER WILL LEAD TO GAS LEAKS AT THE CONTROL WITH POSSIBLE FIRE OR EXPLOSION. Include a manual shut-off valve and union in the line so the control or heater may be disconnected for servicing. Include a drip leg and a plugged 1/8" N.P.T. tapping into the line also. The tapping must be accessible for the test gauge connection immediately upstream of the gas supply connection to the unit. Use a soap and water solution or liquid gas leak detector to coat each joint in the piping system and look for bubbles which indicate gas leaks. Repair all gas leaks. CAUTION: THE APPLIANCE AND ITS APPLIANCE MAIN GAS VALVE MUST BE DISCONNECTED FROM THE GAS SUPPLY PIPING SYSTEM DURING ANY PRESSURE TESTING OF THAT SYSTEM AT TEST PRESSURES IN EXCESS OF 1/2 PSI (3.5 KPA). THE APPLIANCE MUST BE ISOLATED FROM THE GAS SUPPLY PIPING SYSTEM BY CLOSING THE EQUIPMENT SHUTOFF VALVE DURING ANY PRESSURE TESTING OF THE GAS SUPPLY PIPING SYSTEM AT TEST PRESSURES EQUAL TO OR LESS THAN 1/2 PSI (3.5 KPA). DANGER: DO NOT USE CANDLES, MATCHES OR OTHER IGNITION SOURCES WHEN CHECKING FOR LEAKS. FUEL GASES ARE VERY FLAMMABLE AND IN CERTAIN CONCENTRATIONS, EXPLOSIVE. CHECKING FOR LEAKS WITH AN OPEN FLAME MAY LEAD TO FIRE OR EXPLOSION. GAS PIPING AND GAS PRESSURE REQUIREMENTS 5 06/24/2021 INSTALLATION INSTRUCTIONS In planning the installation for the it is necessary to determine ^here the unit is to be installed the routing of the B-type ]ent system and ^hether optional accessories are to be used gas supply piping should also be planned. The can be mounted on any of the follo^ing surfaces! 1. A combustible surface. 2. A raised ^ooden platform. 3. Four 4 corner supports. E_ample! four 4 concrete masonry blocRs. These supports must be positioned so they contact all four corner edges on the bottom of the unit. If the is installed directly on carpeting tile or other combustible material other than ^ood the appliance shall be installed on a metal or ^ood panel e_tending the full ^idth and depth of the unit. Fireplace framing can be built before or after the is set in place. Framing should be positioned to accommodate ^all co]ering and facing material. The framing should be constructed of 2 _ 4 lumber or hea]ier. The framing headers may rest on the standoffs. Refer to Figure .1 for and framing reference dimensions. CAUTION: VERIFY FIREPLACE DIMENSIONS, FRAMING METHODS AND WALL COVERING DETAILS BEFORE FRAMING CONSTRUCTION BEGINS. Determine the e_act position of the so that the ]ent run can be planned. Figure 2.1 sho^s possible locations for the inside of a room mount in a chase. Using a le]el maRe sure the ILUHSODFH LV SURSHUO\ positioned and squared. WARNING: DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES. CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE. 6 MRGHO LFP9618 wLWK WKH XVH RI WKH OXWVLGH ALU .LW FDQ EH LQVWDOOHG LQ D EHGURRP LQ WKH UQLWHG SWDWHV wKLFK KDV D WRWDO YROXPH RI XQFRQILQHG VSDFH DSSURSULDWH WR WKH SDUWLFXODU LQVWDOODWLRQ. RHIHU WR WKH NDWLRQDO FXHO GDV CRGH ANSI =.1/NFPA   FXUUHQW HGLWLRQ  WKH UQLIRUP MHFKDQLFDO CRGH  FXUUHQW HGLWLRQ  DQG LRFDO BXLOGLQJ OIILFLDOV IRU WKH RSWLRQV DOORwHG LQ REWDLQLQJ DQ HIIHFWLYH EHGURRP YROXPH RI XQFRQILQHG VSDFH. 06/24/2021 Installing Chimney/Vent System  MINIMUM FRAMING DIMENSIONS PRIOR TO POSITIONING UNIT FINISHED FRAMING DIMENSIONS WITH UNIT IN POSITION NOTE: DIMENSIONS PRIOR TO POSITIONING FIREPLACE ALLOWS CLEARANCE FOR OUTSIDE AIR COLLARS AS WELL AS FIREPLACE HEADER TO BE NAILED AT CORRECT HEIGHT AFTER BOX HAS BEEN SET. 11”TOP VIEW FIREPLACE IS POSITIONED MINIMUM FRAMING DIMENSIONS 52 1/2" 52" 30 1/2" 76 1/2" INSTALLED AFTER INSTALLED AFTER FIREPLACE IS POSITIONED 24” 32” 52” Figure  18” 48 11/16” 4 1/8” 29” 2 1/2” 6 1/2” 23 1/2” 4” 7” 111”W X 52”H X 24” D 16”W X 32”H X 24”D A B C D MINI080 FRAMING DIMENSIONS LFP LFP 18 A " B " C 6" D  3/4" Model LFP9618 LV approved to be used with 1" B-Type Gas Vent. TKH FLUHSODFH PXVW EH LQVWDOOHG wLWK DQ EQHUYH[ MRGHO RS 1 E[KDXVW FDQ PDS1 RU ADC1 DUDIW SwLWFK WKDW LV FRQQHFWHG WR WKLV FLUHSODFH. WARNING: TKLV FLUHSODFH PXVW QRW EH LQVWDOOHG wLWKRXW E[KDXVW FDQ GROGHQ BORXQW IQF. FDQ VXSSO\ WKH EQHUYH[ SURGXFWV RU WKH\ FDQ EH SXUFKDVHG WKURXJK D WKLUG SDUW\ VXSSOLHU. WARNING: A PURYHQ DUDIW SwLWFK PXVW EH LQVWDOOHG wLWK WKH E[KDXVW FDQ DQG FRQQHFWHG WR WKLV FLUHSODFH. A PURYHQ DUDIW SwLWFK wLOO SUHYHQW WKLV ILUHSODFH IURP RSHUDWLQJ LI WKH E[KDXVW FDQ LV QRW SURYLGLQJ SURSHU Hvacuation RI IOXH JDVHV. Note: Detailed instructions for Enervex Exhaust Fan, Power Draft Switch installation is included in the Enervex Products. 06/24/2021  /)3A33R29('9(N7&2N)IG8RA7I2N6 T K H F R O O R w L Q J R H T X L U H P H Q W s M X V W B H M H W : IF YOUR DESIRED INSTALLATION DOES NOT MEET THE ABOVE RE4UIREMENTS CONTACT GOLDEN BLOUNT INC. TO VERIFY IF DESIRED INSTALLATION CAN BE CONGIFURED WITH OTHER APPROVED POWER VENT E;HAUST FAN. 18811 WARNING:7KLVJDVDSSOLDQFHPXVWQRWEHFRQQHFWHGWRDFKLPQH\IOXHVHUYLQJDVHSDUDWH VROLGIXHOEXUQLQJDSSOLDQFH NRWH:DGUDIWKRRGLVLQVWDOOHGDQGLVLQWKHVDPHDWPRVSKHULFSUHVVXUH]RQHDVWKHFRPEXVWLRQDLU LQOHWWRWKHDSSOLDQFHDQGLVORFDWHGVRWKDWWKHUHOLHIRSHQLQJLVDFFHVVLEOHIRUFKHFNLQJYHQW RSHUDWLRQ ƒMinimum Vent Length ---------5' ƒMaximum Vertical Run --------50' ƒMaximum Horizontal Run -----50' ƒMaximum 45 Deg. Elbows ----4 ea. ƒMaximum 90 Deg. Elbow ------3 ea. 06/24/2021 Installing Outside Air Kit Model LFP9618 LV supplied ^ith the component parts for outside combustion ^ith the e_ception of the4"duct. It is recommended that the outsid e air system be used ^hene]er possible. Connect 4" Class-1 Fle_ duct or Metal =ent to duct collarV on side of ILUHER[ UXQ GXFW WR IUHVK DLU VRXUFH DQG WHUPLQDWH XVLQJ GXFW termination capV. The Outside air can be opened by pulling control Rnob to^ard front of ILUHSODFH DQG closed by pushing to^ards rear Refer to .1. CONTROL 2NOB DUCT TERMINATION LEFT SIDE LFP4218 LEFT AND RIGHT LFP6018 RAIN CAP CAUL2ING WALL OUTER CASING DUCT COLLAR TWO SUPPLIED Figure 9.1 Connecting the Gas Line  Finishing the Wall Finish the ^all ^ith the material of your choice. Do not install a combustible mantle or other combustible proQection abo]e the opening unless it is a minimum of 12 inches abo]e top of opening. Figure 9. CAUTION: All Qoints bet^een the ^all and the surround Top and Sides can only be sealed ^ith non-combustible material. Only non-combustible material can be applied as facing to the surround. Figure 9.) Hearth Extension A Hearth E_tension may be installed. But it is not required for ]ented gas STUD 2?4 HEADER FINISHED WALL NON-COMBUSTIBLE SEAL 1OINT MANTLE 12" MIN TOP OF OPENING Figure  Consult local building codes before gas line installation. This gas fireplace is designed to accept a 1/2" supply line. Have the gas line installed by a qualified service person in accordance with all building codes. Install gas line to fireplace on the right side attaching gas line to the gas flex line inside the control box accessed by opening the control box door. 06/24/2021 Figure 10.1 10 GLASS INSTALLATION (optional) 1.MODEL LFP9618 can be used with approved Fireglass to enhance the overall appearance. 2. Fill the burner tray below and up to the top of the burner ports. Do not cover burner ports. 3. Distribute additional glass around front, sides and rear of burner tray, covering floor area. (Figures 10.1-10.2) GLASS INSTALLATION CONT. Figure 10.2 06/24/2021 11 GLASS FLAME STABILIZER INSTALLATION ÓÖ ALL LFP MODELS ARE SUPPLIED WITH A GLASS FLAME STABILIZER THAT HELPS BURNER FLAME MAINTAIN A VERTICAL POSITION. ÒÖ LOCATE GLASS FLAME STABILIZER CLIPS AND INSERT GLASS FLAME STABILIZER INTO THEM. CENTER GLASS FLAME STABILIZER SO THAT THERE IS SAME CLEARANCE ON LEFT AND RIGHT SIDES. 3. GLASS FLAME STABILIZER SHOULD BE SEATED AGAINST FIREPLACE FLOOR AS SHOWN 06/24/2021 12 Upon completing the gas line connection, a small amount of air will be in the lines. When lighting the pilot light, it will take a few minutes for the lines to purge themselves of this air. Once the purging is complete, the pilot and burner will light and operate as indicated in the instruction manual. Subsequent lighting of the appliance will not require such purging. WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE. IMPORTANT: TURN OFF GAS BEFORE SERVICING APPLIANCE. IT IS RECOMMENDED THAT A COMPETENT SERVICE TECHNICIAN PERFORM THESE CHECKUPS AT THE BEGINNING OF EACH HEATING SEASON. WARNING: THE FLOW OF COMBUSTION AND VENTILATION AIR MUST NOT BE OBSTRUCTED. When lit for the time, the appliance will emit a slight odor for an hour or two. This is due to paint and lubricants used in the manufacturing process. The main burner characteristics are steady, not lifting or Typically, the top 1/4 inch of the sensor should be engulfed in the pilot A periodic check of these characteristics is necessary (Figure 12.1). Figure  OPERATING GUIDELINES Flame Sensor MAINTENANCE INSTRUCTIONS IMPORTANT: THE APPLIANCE AREA MUST BE KEPT CLEAR AND FREE FROM COMBUSTIBLE MATERIALS, GASOLINE AND OTHER FLAMMABLE VAPORS AND LIQUIDS. Visually inspect pilot periodically. Brush or blow away any dust or linen accumulations. If pilot is plugged, disassembly may be required to remove any foreign material from or tubing. service technician or Venting system should be periodically examined by a agency to ensure proper air 06/24/2021 13 WIRING DIAGRAM 06/24/2021 14 FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF @OU DO NOT FOLLOW THESE INSTRUCTIONS E?ACTL@ A FIRE OR E?PLOSION MA@ RESULT CAUSING PROPERT@ DAMAGE PERSONAL IN1UR@ OR LOSS OF LIFE. A. This appliance is equipped ^ith an ignition de]ice ^hich automatically lights the pilot. Do not light pilot by hand. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell ne_t to the because some gas is hea]ier than air and ^ill settle on the WHAT TO DO IF YOU SMELL GAS: ‹ Do not try to light any appliance ‹ Do not touch any electric s^itch! ‹ Do not use any phone in your building. ‹ Immediately call your gas supplier from a neighbor»s phone. Follo^ the gas supplier»s instructions C. Do not use this appliance if any part has been under ^ater. Immediately call a ser]ice technician to inspect the appliance and to replace any part of the gas control system ^hich has been under ^ater. LIGHTING INSTRUCTIONS ELEC. SPARK TO PILOT NOTE: DAMPER CONTROL LEVER MUST BE IN THE “OPEN” POSITION TO IGNITE. GAS VALVE AQ DSSURYHG PRwHU VHQW FDQ PXVW EH LQVWDOOHG SULRU WR RSHUDWLQJ WKLV FLUHSODFH. SHH SDJH 8 RI WKLV PDQXDO IRU IDQ LQIRUPDWLRQ. D. 1.“STOP” Read the safety information above. 2.After installing Enervex RS-14 Power Vent and Proven Draft Switch you can proceed with lighting of this Fireplace 3.Set the switch to “OFF”. 4.Remove batteries from battery pack. 5. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 6.Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to next step. 7.Install (2) D batteries in battery pack. 8.Turn ON/OFF rocker switch to " ON". 9.If the appliance will not operate, follow the instructions “To turn Off Gas To Appliance” and call your service technician or gas supplier. NOTE: THIS FIREPLACE CAN ALSO BE SERVICED WITH 120V JUNCTION BOX AND 3-VOLT TRANSFORMER WHICH CAN BE USED TO PROVIDE POWER IF DESIRED (PART# JB-3V). 06/24/2021 15 TO TURN OFF GAS TO APPLIANCE 1. Turn ON/OFF rocRer s^itch to ¸OFF¹ 2. Remo]e batteries from appliance if ser]ice is to be performed. LPG (PROPANE) WARNING THE FOLLOWING WARNING APPLIES TO INSTALLATIONS USING L.P. PROPANE GAS! WARNING! To a]oid possible inQury and e_plosion please read and follo^ these precautions and all instructions of this appliance before operating. This appliance uses L.P. Propane gas ^hich is hea]ier than air and ^ill remain at the le]el is there is a leaR. Before lighting smell at le]el and/or use other means such as using a soap solution on all piping and connections using a gas detector etc. to checR for gas leaRs. NOTE! L.P. Propane gas can become odorless and CANNOT al^ays be detected by smell. If you smell gas detect a gas leaR or suspect that a gas leaR e_ists follo^ these rules! 1. Get all people out of building. 2. DO NOT light matches. DO NOT turn electric lights or s^itches on or off in area. DO NOT use an electric fan to remo]e gas from area. DO NOT use a telephone inside of building. 3. Shut off gas at L.P. tanR outside of building. 4. Telephone gas company and department. AsR instructions. Before hanging up gi]e your name address and phone number. DO NOT go bacR into building. If your L.P. tanR runs out of fuel turn off gas at the appliance. After L.P. tanR is appliance TO TURN OFF GAS TO APPLIANCE must be re-lit according to manufacturer»s instructions. If The gas control has been e_posed to WATER in any ^ay DO NOT try to use it. It must be replaced. DO NOT attempt repair on gas control or appliance. Tampering is DANGEROUS and ]oids all ^arranties. Any component that is found to be faulty must be replaced ^ith an appro]ed component. IMPORTANT: Always keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids. Never obstruct the flow of combustion and ventilation air. Keep the front of the appliance clear of all obstacles and materials. To obtain proper operation, it is imperative that the pilot and main burner flame characteristics are steady, not lifting or floating. Typically the top 1/4 Inch of the flame sensor should be engulfed in the pilot flame. (Figure 12.1) 06/24/2021 16 Enervex Fan not operating and connecting Draft Switch to operate Fireplace. 9.Check to see if Enervex Fan is running and Draft Switch is closing Fireplace circuit. 9. 13 06/24/2021 17 06/24/2021 REPLACEMENT PARTS THE FOLLOWING REPLACEMENT PARTS ARE AVAILABLE FROM YOUR GOLDEN BLOUNT DEALER 1 2 3 6 10 11 12 16 15 4 14 13 18 7 8 9 06/24/2021 19 , Inc. 06/24/2021