Loading...
HomeMy WebLinkAboutFile Documents.183 Red Mountain Rd.0060-2020-BCHO (11)0060-2020-BCHO_183 Red Mtn_BuildingComment1 Subject: PlanCheck Page: 1 Author: justinh Color: File Name: 30.Fireplace Registration Form.20200814.pdf Fireplace registration form should represent all fireplaces for the project. Revise the form to accurately account for all proposed fireplaces and provide installation instructions for all the proposed units since all models seem to have changed from the previously approved plan. 30.Fireplace Registration Form.20200814.pdf (3) Subject: PlanCheck Page: 3 Author: justinh Color: File Name: 30.Fireplace Registration Form.20200814.pdf You will either need sealed/gasketed doors on the gas fireplaces or they will need a flue sentinel per City Policy. Installation without glass must be approved by the manufacturer as well, we won't approve anything not approved by the manufacturer. Include full installation instructions for all proposed fireplaces and gas appliances so that we can verify the detailing shown in architectural plans complies with the manufacturer's installation requirements. Subject: PlanCheck Page: 4 Author: justinh Color: File Name: 30.Fireplace Registration Form.20200814.pdf Who is making these redlines on the fireplace drawings? The installation needs to comply with the manufacturer's installation instructions. Verify that stellar hearth approves this change in design. Subject: PlanCheck Page: 1 Author: justinh Color: File Name: 30.REMP Worksheet.20200814.pdf The amount previously paid on the master permit was $120,619.18. Fill out the previously paid on this permit cell of the REMP form to calculate the refund. 30.REMP Worksheet.20200814.pdf (1) City of Aspen and Pitkin County FIREPLACE & WOODSTOVE REGISTRATION *Required—Contact Assessors offices at 920-5160 Registration will not be accepted without a Parcel Id number List all devices in your home (2 are allowed per building, except for gas appliances) Note: If the number, type and location on this registration form do not match what is show on your plans or what is actually installed, your permit or Certificate of Occupancy will be denied. Type of Building (circle one): Residential Other Type of device Room Existing New Make & Model Wood burning fireplace (select one) ?Site-built masonry ?Factory built insert: model number: _____________________ Gas log fireplace (select one) ?Site-built masonry ?Factory built insert: model number: _____________________ Certified woodstove Gas fireplace appliance (attach spec sheet) If any devices are being removed, please describe here, i.e. “old woodstove removed from living room” · __________________________________________________________________________________ · __________________________________________________________________________________ · __________________________________________________________________________________ _______________________________________________________ ____________________________ Signature of applicant Date *Parcel Id number:____ ____ ____ ____ -- ____ ____ ____ -- ____ ____ -- ____ ____ ____ Street Address:_________________________________________________________________________ Owners Name:_________________________________________________________________________ 2 7 3 7 0 7 2 0 0 0 2 6 183 Red Mountain Rd SHADY RED MOUNTAIN LLC Living Room Isokern Magnum 60 Suite 3 Marquis Bentley 39 2020-08-07 Fireplace registration form should represent all fireplaces for the project. Revise the form to accurately account for all proposed fireplaces and provide installation instructions for all the proposed units since all models seem to have changed from the previously approved plan. SUNKEN DEN FIREPLACE Stellar “Bay-Modern-Open Hearth” gas fireplace. This fireplace opening (no glass) to be 5’ wide x 2’ high x 30” deep. Approximately 70’ of 14” B-vent flue, offsets, and power-vented termination with sound reduction chamber and mechanical power damper. Modern look with a ribbon burner down the long axis. Will require 120VAC, 5 amp power to fireplace and power-damper location. 1,200 CFM of make-up air to be provided by Mechanical contractor. 80,000 BTU capacity will we be able to accomplish this without glass? Sunken Den You will either need sealed/gasketed doors on the gas fireplaces or they will need a flue sentinel per City Policy. Installation without glass must be approved by the manufacturer as well, we won't approve anything not approved by the manufacturer. Include full installation instructions for all proposed fireplaces and gas appliances so that we can verify the detailing shown in architectural plans complies with the manufacturer's installation requirements. 14" FLUEB-VENT 30 1/32" 1 5 4 3 Changed to (2) 10.5" flues routed to upper level ceiling and transition to a single 14" flue through the roof Who is making these redlines on the fireplace drawings? The installation needs to comply with the manufacturer's installation instructions. Verify that stellar hearth approves this change in design. A.RESIDENTIAL RENEWABLE ENERGY MITIGATION PROGRAMSheets showing snowmelt, pool, spa, and solar/GSHP information: Do you have snowmelt or a spa that has been exempted by the buiding official? Hydro Snowmelt Electric Snowmelt Pool SpaExistingTo be DemoedExisting to Remain 0.00 sqft 0.00 sqft 0.00 sqft 0.00 sqftNew (non-exempt)2520.78 sqft 0.00 sqft 76.25 sqftNew (exempt)Total New 2520.78 sqft 0.00 sqft 0.00 sqft 76.25 sqftTotal on site 2520.78 sqft 0.00 sqft 0.00 sqft 76.25 sqftTotal Snowmelt on siteBoiler Efficiency 98.0%100%75.0%98.0%Mitigation Payment -$ 13,693.88$ Total Payment for Mitigation:101,149.51$ B.ON-SITE RENEWABLE CREDITS Supplemental System REMP CreditUse PV Worksheet Photovoltaic System -$ Use Thermal Worksheet Hot Water Panels -$ Use GSHP Cert Ground Source Heat Pump -$ Other Approved System -$ Total Mitigation Credits:-$ Onsite Renewable Offsets:How many KiloWatts of PV (solar electric) would I need? 14.73 or How many square feet of SHW (solar hot water) would I need?450.25 R-REMP Payment:101,149.51$ Amount Previously Paid on This Permit:101,149.51$ Refund (includes minus $750):-$ C. PREPARED BY:Date:6/10/2020 Print Name: Signature: Phone & EMail: REVIEWED:Date: 970-748-8520, Burban@AEC-Vail.com TOTAL R-REMP PAYMENT: 2520.78 sqft Bryan Urban M-121, M-122 $87,455.63 Yes (enter sqft below on the exempt row)No The amount previously paid on the master permit was $120,619.18. Fill out the previously paid on this permit cell of the REMP form to calculate the refund. Form revised and new installation instructions attached. A flue sentinel will be provided. Please review attached installation instructions. Thanks, filled out. The GC was making comments during the vetting process. All FPs will be installed per manufacture’s Instructions. Drawings, specs and installation instructions from the manufacturer provided. 02/17/2021 Subject: PlanCheck Page: A1.2 ROF PLAN Author: justinh Color: File Name: 90.Architecture Change Order 1.20200814.pdf You are no longer showing scuppers on this side of your roof, revise to show compliant secondary drainage per IRC 903.4.1 90.Architecture Change Order 1.20200814.pdf (5) Subject: PlanCheck Page: A1.02 SNOWMELT PLAN | 1/8" Author: justinh Color: File Name: 90.Architecture Change Order 1.20200814.pdf What does this symbol represent? Please clarify. Subject: PlanCheck Page: A1.04 GROUND LEVELFLOR PLAN Author: justinh Color: File Name: 90.Architecture Change Order 1.20200814.pdf Bubble changes on all plan sheets in all sets, as required for all change orders. Subject: PlanCheck Page: A2.01 ELEVATIONS Author: justinh Color: File Name: 90.Architecture Change Order 1.20200814.pdf You do not appear to have the required separation between the OA intake and the fireplace vent. Revise architectural and mechanical plans as needed to demonstrate compliance. Subject: PlanCheck Page: A7.10 STAIR DETAILS Author: justinh Color: File Name: 90.Architecture Change Order 1.20200814.pdf Revise handrail grip to comply as either a type I or type II handrail. 129'-0" 47'-21/4"2'-11"29'-10"2'-11"13'-111/4"7'-31/4" 3'-101/2" 22'-41/2" 3'-101/2" 3'-101/2" 47'-21/4"2'-11"29'-10"2'-11"21'-21/2" 128'-113/4" 34'-10" 16'-0" 16'-03/4"110'-21/2"T.O. PLY7859'-81/2" 115'-7"T.O. CHIMNEY CAP115'-7"T.O. CHIMNEY CAP 112'-4"T.O. PARAPET 112'-4"T.O. PARAPET 1/8" PER FOOT 1/8" PER FOOT 1/8" PER FOOT 1/8" PER FOOT 1/8" PER FOOT 1/8" PER FOOT 1/8" PER FOOT 1/8" PER FOOT 1/8" PER FOOT 1/8" PER FOOT 1/8" PER FOOT 1/8" PER FOOT 1/8" PER FOOT 1/8" PER FOOT 1/8" PER FOOT 1/8" PER FOOT 1/8" PER FOOT 1/8" PER FOOT 1/8" PER FOOT 1/8" PER FOOT 1/8" PER FOOT 1/8" PER FOOT 1/8" PER FOOT 1/8" PER FOOT 1/8" PER FOOT 1/8" PER FOOT 1/8" PER FOOT1/8" PER FOOT 1/8" PER FOOT 1/8" PER FOOT 1 1 MATCH LINE MATCH LINE 7 7 6 6 9 9 10 10 13 13 11 11 2 2 4 4 3 3 12 12 5 5 8 8 AA3.01 AA3.01 BA3.02 BA3.02 DA3.04 DA3.04 EA3.05 EA3.05 FA3.07 FA3.07 GA3.08 GA3.08 LA3.10 LA3.10 MA3.11 MA3.11 NA3.12 1A2.01 2A2.01 3A2.08 1A2.08 2A2.08 111'-85/8"T.O. PLY 7861'-25/8" 4" HYDROTECH GREEN ROOF TYP. BALLAST TYP. TREL TRELLIS FLUESFLUES COMMON VENT STACKCOMMON VENT STACK SSCUPPER FLUE FLUE CUSTOM STEEL EDGE SCUPPER SCUPPER SCALE: 3/16" = 1'-0" ROOF PLAN You are no longer showing scuppers on this side of your roof, revise to showcompliant secondary drainage per IRC 903.4.1 UP 6RISE(6") 5RUN(12") What does this symbol represent? Please clarify. NOTE: RE: LANDSCAPE Bubble changes on all plan sheets in all sets, as required for all change orders. 2 EQUAL PANELS 2 EQUAL PANELS LAMB'S TONGUE H.B. A24A22A21 B00B01B04116 B31 A17 B30 A07 B29 A18 A14 B18 A12 A11 A09A15 B22 B24 B28B36 ALIGN You do not appear to have the required separation between the OA intake and the fireplace vent. Revise architectural and mechanical plans as needed to demonstrate compliance. 3A7.10 71/16" 41/16" 5/8" 23/8" 2'-10" 2" 1/2"13/4"11/4"11" 4" GLASS PA 11/4" 11/2" 9" 3" 2'-10" 2" 11/2" 11/2" 9" 3" 2'-10" 2" 11/2" VERIFY IN SHOPS 13/4" 11/2" 11/2" 7/8" 13/16" 9/16"7/8"1/8"1/8"1/2"1/8"15/8" 7/8" 13/16" 11/16" 1" KURV-SW AST 0 1'2'4'SCALE: 1' = 1'-0"3 GRIP RAIL 0 1/2''1''2'' Revise handrail grip to comply as either a type I or type II handrail. Scuppers added Those are yard drain inlets bubbles added separation clarified. Flue is 3 ft above Detail has been brought into compliance 02/17/2021 Subject: PlanCheck Page: M-001 MECHANICAL•50LEGEND &•50SPECS Author: justinh Color: File Name: 90.Mechanical & Plumbing Change Order 1.20200814.pdf Revise the occupiable floor area to be accurate. 90.Mechanical & Plumbing Change Order 1.20200814.pdf (2) Subject: PlanCheck Page: M-002 MECHANICAL•50SEQUENCE &•50PIPING•50DIAGRAMS Author: justinh Color: File Name: 90.Mechanical & Plumbing Change Order 1.20200814.pdf The required ventilation rate on M-001 seems to be assuming the system runs continuously by my calculation. Revise that table to reflect the 50% intermittent run time you call out here. Revise the occupiable floor area to be accurate. The required ventilation rate on M-001 seems to be assuming the system runs continuously by my calculation. Revise that table to reflect the 50% intermittent run time you call out here. table updated table updated 02/17/2021