Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.1039 E Cooper Ave.0049-2020-BCHO (13)
Job Name: System Reference:Date: Indoor Unit: MSZ-GL06NA Wireless Remote Controller GENERAL FEATURES •Slim wall-mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • Multiple fan speed options: Quiet, Low, Medium, High, Super-high, Auto • Multiple control options available: - Hand-held Remote Controller (provided with unit) - kumo cloud® smart device app for remote access - Third-party interface options - Wired or wireless controllers • Hot-Start Technology: no cold air rush at equipment startup or when restarting after Defrost Cycle • Quiet operation • Smart Set: recalls a preferred preset temperature setting at the touch of a button SUBMITTAL DATA: MSZ-GL06NA 6,000 BTU/H WALL-MOUNTED INDOOR UNIT FOR MXZ-C MULTI-ZONE HEAT PUMP SYSTEMS Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. M-SERIES 07/20/2020 Cooling Capacity1, 3 BTU/H 6,000 Heating Capacity2, 3 BTU/H 7,200 Electrical Voltage, Phase, Frequency 208/230V, 1 phase, 60Hz Guaranteed Voltage Range V AC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208 / 230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating (SCCR)Wireless Type MCA A 1 Blower Motor Full Load Amperage A 0.76 Blower Motor Output W 30 Airflow Rate at Cooling, Dry CFM 145-170-237-321-399 Airflow Rate at Cooling, Wet CFM 109-134-201-286-364 Airflow Rate at Heating, Dry CFM 145-170-237-321-406 Sound Pressure Level (Cooling)dB(A)19-22-30-37-43 Sound Pressure Level (Heating)dB(A)19-22-30-37-43 Drain Pipe Size In. (mm)5/8 (15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.0Y 9.2/0.2 Unit Dimensions W: In. (mm)31-7/16 (798) D: In. (mm)9-1/8 (232) H: In. (mm)11-5/8 (295) Package Dimensions W: In. (mm)33-1/2 (850) D: In. (mm)12 (300) H: In. (mm)14 (350) Unit Weight Lbs. (kg)22 (10) Package Weight Lbs. (kg)26 (11.5) Refrigerant Type R410A Piping Gas Pipe Size O.D. (Flared)In. (mm)3/8 (9.52) Liquid Pipe Size O.D. (Flared)In. (mm)1/4 (6.35) Notes: Nominal Conditions 1Cooling (Indoor // Outdoor)°F 80 DB, 67 WB // 95 DB, 75 WB 2Heating at 47°F (Indoor // Outdoor)°F 70 DB, 60 WB // 47 DB, 43 WB 3Capacity varies based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit. For reference to connected capacity charts, please refer Multi-zone Outdoor Unit Operational Performance. SPECIFICATIONS: MSZ-GL06NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 07/20/2020 Anti-allergy Enzyme Filter □ MAC-408FT-E kumo touch™ RedLINK™ Wireless Controller □ MHK2 Deluxe MA Remote Controller1 □ PAR-40MAAU Simple MA Controller1 □ PAC-YT53CRAU-J Touch MA Controller1 □ PAR-CT01MAU-SB Wired Remote Sensor □ M21-EAA-307 Wireless Temperature and Humidity Sensor □ PAC-USWHS003-TH-1 System Control Interface2 □ MAC-334IF-E Wireless Interface 2 □ PAC-USWHS002-WF-2 Thermostat Interface □ PAC-US444CN-1 kumo station®□ PAC-WHS01HC-E USNAP Interface □ PAC-WHS01UP-E IT Extender □ PAC-WHS01IE-E BACnet® and MODBUS® Interface □ PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers □ RCMKP1CB Blue Diamond Sensor Extension Cable —15 Ft.□ C13-103 Blue Diamond Alarm Extension Cable —6.5 Ft.□ C13-192 Blue Diamond MultiTank —collection tank for use with multiple pumps □ C21-014 Blue Diamond Rubber Foot Pads □ F10-010 Mini Condensate Pump —230 volt application □ SI30-230 MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor □ X87-835 - 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 BTU/ H[recommended] □ X87-711 - 110V Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended]□ X87-721 - 208/230V MicroBlue Blue Diamond Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H □ X85-003 Fascia Kit for MicroBlue Pump – mounts the MicroBlue and sensor directly beneath the indoor unit □ T18-016 Drain Pan Level Sensor □ SS610E (30A/600V/UL) [fits 2" X 4" utility box] - Black □ TAZ-MS303 (30A/600V/UL) [fits 2" X 4" utility box] - White □ TAZ-MS303W 1 Requires MAC-334IF-E 2 Allows indoor units to connect to an MA Controller ACCESSORIES: MSZ-GL06NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 07/20/2020 Unit: inch Pi p i n g Insulation ø1 - 3/8 O.D Liquid line ø1/4 19 - 11/16 (Flared connection ø1/4) Gas line ø3/8 16 - 15/16 (Flared connection: ø3/8 (06/09/12 KBTU/H), ø1/2 (15 KBTU/H) Drain hose Insulation ø1-1/8 O.D Connected part ø5/8 O.D FORM# MSZ-GL06NA FOR MXZ-C MULTI-ZONE HEAT PUMP SYSTEMS - 202003 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com DIMENSIONS: MSZ-GL06NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 07/20/2020