HomeMy WebLinkAboutFile Documents.395 Thunderbowl Ln.0002-2020-BCHO (17)(G)
(D)
(E)
(F)
4"
12
0
"
(A)
- Burner and jets should be
covered by up to 1/2” of media
above jets.
- 12 - 13" Minimum clearance
below plate required for
electronic ignition
(H)
36"
(C)
(B)
10
"
(I)
CROSSFIRE™
Brass Burner Aluminum
Plate/Pan
Fire Pit Cavity Components
(A) GFCI Outlet
(B) Location for remote receiver (optional)
(C) Pigtail plug included for easy installation
(D) Electronics Box (Houses 120V - 24V Transformer)
(E) 24V Power from Transformer to Gas Valve
(F) Gas Valve / Control Box
(G) Pilot Assembly
(H) Gas Valve Supply IN
(I) Gas Stub from source
110V\120V
Power Line
Required 18 sq.
inches of venting, or
equivalent, on
OPPOSING sides of
fire pit. (36 inches total.)
Enclosure constructed
of all non-combustible
materialsCapstoneCapstone
EMERGENCYSTOP
PUSH
Emergency
Stop Push
Button
(Optional)
2 hr or 12 hr
Dial Timer
(Optional)
External power switch
required for all
electronic ignitions
(other than battery
operated ignitions)
Clearances
from combustible
structure or
materials
Recomended Clearance to Combustibles 03/19/2020