Loading...
HomeMy WebLinkAboutFile Documents.395 Thunderbowl Ln.0153.2017 (65).ARBKE E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G FND 58" REBAR WITH 1 14" PLASTIC CAP, PLS 33638 ELEV: 8243.24' FND 58" REBAR WITH 1 14" PLASTIC CAP, PLS 33638 ELEV: 8242.57' FND 58" REBAR WITH 1 14" PLASTIC CAP, PLS 33638 ELEV: 8240.47' FND 58" REBAR WITH 1 14" PLASTIC CAP, PLS 33638 ELEV: 8235.30' FND 58" REBAR WITH 1 14" RED PLASTIC CAP FND 58" REBAR WITH 1 14" PLASTIC CAP, PLS 33638 ELEV: 8264.32' FND 58" REBAR WITH 1 14" PLASTIC CAP, PLS 33638 ELEV: 8262.57' N 42 ° 0 9 ' 2 3 " E 1 7 1 . 2 2 ' FND 58" REBAR WITH 1 14" PLASTIC CAP, PLS 33638 ELEV: 8238.76' C 1 C 2 C3 C4 C6 N 1 8 ° 4 6 ' 4 6 " W 1 5 7 . 8 8 ' S 2 0 ° 2 2 ' 0 5 " W 5 3 . 2 1 ' S43 ° 0 4 ' 4 1 " W 417 . 1 7 ( B A S I S O F B E A R I N G ) B U I L D I N G E N V E L O P E 10.0' UTILITY EASEMENT 15.0' 20.0' 10.0' UTILITY EASEMENT S 84°19'25" W 12492. 2 7 ' S 73°1'41 " W 9 9 5 3 . 2 5 ' LOT 8 NOT A PART S S DYH FIRE HYDRANT ELECTRIC TRANSFORMER ELEV: 8235.03' 12" CMP INV: 8233.52' TOP: 8234.52' TELEPHONE PEDESTAL ELEV: 8235.44' E ELECTRIC METER ELEV: 8235.52' PILLAR 8245.06' PILLAR 8245.76' 18" CPP IO: 8246.15' 18" CPP IO: 8244.03' S SEWER MANHOLE RIM: 8252.02' 10" CMP INV: 8257.76' TOP: 8258.96' W W W W W W W OSW WATER METER ELEV: 8242.78' W 12" CMP INV: 8233.90' TOP: 8234.90' E ELECTRIC PANEL 17.4' 14 . 3 ' 1.8' 38 . 7 ' 19.7' 6. 4 ' 12.3'32.6'1. 3 ' 3. 6 ' 22.0' 5. 2 '11.2' 5. 1 ' 5.5'5. 4 ' 2.5'6. 2 ' 2.4' 5. 3 ' 3.2' 9. 2 ' 14.3' 11 . 9 ' 3.0' 25 . 8 ' 2.6' 12 . 2 ' 23.6' 44 . 1 ' 8.0' 8. 4 ' 20.1' 7. 6 ' 13.2' 8. 9 ' 2.2' 4. 4 ' T1 T2 T3 T4 T5 T6 T7 T8 T9 T12 T13 T11 T10 T15T14 T16 T18 T17 T19 T20 T21 T23 T22 T24 T25 T26 T27 T28 T29 T30 T31 T32 T33 T35T34 T36 T38 T37 T39 T40 T43T42 T41 T44 T49T48 T46 T45 T47 T61T60 T62 T59 T54 T53 T52 T56T55 T57 T51 T50 T64 T63 T65 T66 T58 E D G E O F P A V E M E N T 5' ACTIVITY ENVELOPE PER PLAT BK 47 PG 1 LOT 6 NOT A PART PLASTIC PIPE INV=8264.57' 22.35 19.25 32.26 6" PVC 8238.33' 8238.70' 8238.77' 8239.11' 8239.30' ART SLAB 4" PVC 8236.99' 6" PVC 8237.84' 6" PVC 8236.63' 8241.02' 8240.20' 8241.48' 8238.97' 8241.53' 8241.39' 8241.37' 8241.79' 8240.68' RETAINING WALLS 8239.23' 8239.42' 6" PVC 8237.89' 8238.76' FF1 8246.05' ROOF DRAIN 8243.83' WW 8244.86' CO N C R E T E PA D 8247.90' S 80°22'51" E 8 2 . 2 0 ' N 42 ° 0 9 ' 2 3 " E 5 8 . 9 7 ' S 1 8 ° 4 6 ' 4 6 " E 1 2 1 . 8 6 ' C 7 S 2 0 ° 2 2 ' 0 5 " W 5 1 . 0 6 ' C8 C5 SEWER MANHOLE RIM: 8261.65' SEWER MANHOLE RIM: 8235.42' S S S S S S SS S S S S S S SS SS SS SS SS SS SS SS SS SS SS SS S SEWER MANHOLE RIM: 8241.82' WA T E R LIN E SE W E R LIN E GA S LIN E ELECT R I C LINES 8248.10' 8248.01' 8247.81' RETAINING WALL RE T A I N I N G W A L L RE T A I N I N G W A L L RE T A I N I N G WA L L 8252.94' 8251.01' 8251.45' 8251.96' 8248.04' 8247.99' 8247.46'8247.53' 8252.98' 8255.97'8252.99' 8255.90' ENV E L O P E VAULT: 8243.20' 10' PRIVATE SKI EASEMENT & UTILITY EASEMENT PER PLAT BK 47 PG 1 5' ACTIVITY ENVELOPE PER PLAT BK 47 PG 1 10.00 10' ACTIVITY ENVELOPE PER BK 47 PG 1 10" CMP INV: 8252.23' TOP: 8253.43' 10' ACTIVITY ENVELOPE PER BK 47 PG 1 8238.69' 8238.50' 8238.34' 8238.74' 82 4 2 . 0 1 ' 824 2 . 8 8 ' 824 4 . 8 8 ' 824 3 . 4 2 ' 824 4 . 6 5 ' 824 4 . 7 3 ' 8250 . 6 8 ' 8256 . 1 3 ' 8255 . 6 2 ' 8261 . 2 9 ' 8262 . 9 7 ' 8248 . 0 3 ' 824 4 . 6 6 ' WW 8247.99' 8246.75' 8245.88' 8246.30' BUI L D I N G ENVELOPE BUILDING E D G E O F P A V E M E N T WATER FEATURE AND SOME PARTIAL RETAINIG WALLS UNDER CONSTRUCTION PILLAR 8 2 5 5 82 6 0 8 2 6 5 8260 8 2 6 0 8 2 6 5 8 2 5 5 8 2 5 5 8250 8245 8240 8240 82 3 5 8238 8245 1.21% 0.15% 0.7 5 % 1. 7 5 % 1. 1 5 % FD2 5" T R E N C H D R A I N ( T D ) 8244.7 7 ' 824 4 . 7 5 ' FF3 FF2 FF4 FF5 C1 C2 C3 R1 R2 R3 BUILD I N G ENVE L O P E SEE AS-BUILT NOTE #1 G1 G2 G3 G4G5 G6 G7 6.16 % G8 G9 G10 G11 G12 FD1 29 . 8 % 4.39% 1 . 3 2 % 11 . 2 % 4. 1 3 % G13 3 . 5 1 % BOULDER RETAINING WALL 824 4 . 6 6 ' CONCRETE DRIVEWAY FLAGSTONE 0.6 4 % 1 2 3 4 POND #2 3.80% POND #1 4" PVC 8237.09' 4" PVC 8237.66' TRENCH DRAIN TD4 TRENCH DRAIN TD2 TRENCH DRAIN TD3 TRENCH DRAIN TD5 TRENCH DRAIN TD6 TD 7 TD 8 7. 6 5 % CONCRETE PATIO 6" PVC ELEV: 8235.66' 4.83" DIAMETER ORIFICE CITY OF ASPEN GPS #18 ELEV: 8013.41' CITY OF ASPEN GPS #5 ELEV: 7915.94' CURVE TABLE CURVE NO. C1 C2 C3 C4 C5 C6 C7 C8 ARC LENGTH 64.74' 19.64' 48.90' 20.94' 141.15' 13.44' 24.32' 107.96' RADIUS 215.00' 20.00' 50.00' 20.00' 159.85' 305.00' 76.00' 129.85' DELTA ANGLE 17°15'14" 56°15'28" 56°01'48" 60°00'00" 50°35'37" 2°31'29" 18°20'04" 47°38'10" CHORD BEARING N48°29'14"W N11°43'53"W S11°37'03"E N09°37'55"W N45°39'51"E N72°12'23"E S23°02'00"E N44°11'07"E CHORD LENGTH 64.50' 18.86' 46.97' 20.00' 136.61' 13.44' 24.22' 104.88' LEGEND AND NOTES: - INDICATES FOUND MONUMENT AS DESCRIBED - WINDOW WELL - DATE OF SURVEY: NOVEMBER 25, 2020 - UNIT OF MEASUREMENT: US SURVEY FOOT - DUE TO SNOW COVER AT THE TIME OF THIS SURVEY SOME IMPROVEMENTS MAY NOT BE SHOWN. - BUILDING SETBACKS ARE BASED ON ZONING STANDARDS PER PITKIN COUNTY AND SHOULD BE VERIFIED PRIOR TO CONSTRUCTION OR CRITICAL DESIGN. - BEARINGS ARE BASED UPON A #5 REBAR WITH A YELLOW PLASTIC CAP L.S. #20133 AT THE MOST NORTHEASTERLY CORNER OF LOT 7 AND A FOUND #5 REBAR WITH AN ALUMINUM CAP FOUND AT THE SOUTHWESTERLY CORNER OF LOT 6 BOTH IN SAID BLOCK A, USING A BEARING OF S43°04'41"W BETWEEN THE TWO DESCRIBED MONUMENTS. LEGAL DESCRIPTION: LOT 7, BLOCK A, THE ASPEN HIGHLANDS VILLAGE P.U.D., ACCORDING TO THE PLAT THEREOF RECORDED OCTOBER 15, 1998 IN PLAT BOOK 47 AT PAGE 1 AS RECEPTION NO. 423275. COUNTY OF PITKIN, STATE OF COLORADO. NOTICE: ACCORDING TO COLORADO LAW, YOU MUST COMMENCE ANY LEGAL ACTION BASED UPON ANY DEFECT IN THIS SURVEY WITHIN THREE YEARS AFTER YOU FIRST DISCOVER SUCH DEFECT. IN NO EVENT MAY ANY ACTION BASED UPON ANY DEFECT IN THIS SURVEY BE COMMENCED MORE THAN TEN YEARS FROM THE DATE OF THE CERTIFICATION SHOWN HEREON. AS-BUILT SURVEY STATEMENT I, THE UNDERSIGNED REGISTERED LAND SURVEYOR, HEREBY CERTIFY THAT THE ELEVATIONS, GRADING AND DRAINAGE FEATURES SHOWN OF THE PROPERTY DESCRIBED AS: LOT 7, BLOCK A, THE ASPEN HIGHLANDS VILLAGE P.U.D., ACCORDING TO THE PLAT THEREOF RECORDED OCTOBER 15, 1998 IN PLAT BOOK 47 AT PAGE 1 AS RECEPTION NO. 423275 WERE DEVELOPED FROM SURVEYING THE PROPERTY ON THE DATE OF NOVEMBER 25, 2020. AND ACCURATELY DEPICT THE ELEVATIONS EXISTING DURING THE SURVEY. THE ELEVATIONS MAY CHANGE SUBSEQUENT TO THE SURVEY DUE TO SUBSIDENCE, UPHEAVAL, EROSION, ACTS OF MAN OR OTHER FACTORS. THEREFORE, THIS CERTIFICATE MAY NOT ACCURATELY DEPICT ELEVATION, GRADING AND DRAINAGE PATTERS AFTER THE DATE OF SURVEY. EASEMENTS ARE SHOWN PER THE PLAT UNLESS NOTED OTHERWISE. NO PART OF THIS LOT LIES WITHIN THE 100- YEAR FLOODPLAIN AS DEFINED BY FEMA, EXCEPT AS NOTED JEFFREY A. TUTTLE, COLORADO P.L.S. NO. 33638 FOR, AND ON BEHALF OF TUTTLE SURVEYING SERVICES. ___________________________________________02/04/2021______ JEFFREY ALLEN TUTTLE L.S. 33638 DATE No r t h FND 5/8" REBAR WITH 1 12" ALUMINUM CAP 020 20 40 8010 WW AS-BUILT ENGINEERING CERTIFICATION STATEMENT: I, THE UNDERSIGNED REGISTERED PROFESSIONAL ENGINEER, CERTIFY THAT I HAVE INSPECTED THE AS-BUILT SURVEY DATA FOR PROJECT SITE: AS-BUILT SURVEY LOT 7, BLOCK A, THE ASPEN HIGHLANDS VILLAGE P.U.D., ACCORDING TO THE PLAT THEREOF RECORDED OCTOBER 15, 1998 IN PLAT BOOK 47 AT PAGE 1 AS RECEPTION NO. 423275, AND HAVE CONCLUDED THAT THE PROPERTY WILL DRAIN ADEQUATELY IN CONFORMANCE WITH THE DRAINAGE PLAN SUBMITTED AND APPROVED BY THE CITY ON DATE: ____________________. BY: DATE: _________________ PE LICENSE NO. _______________________ FINISHED FLOOR, CHIMNEY AND RIDGE ELEVATIONS: NUMBER ELEVATION LOCATION FF1 8245.34'HOUSE ENTRY FF2 8244.72'GARAGE FF3 8244.73'GARAGE FF4 8245.24'HOUSE FF5 8245.07'HOUSE C1 8277.97'CHIMNEY C2 8278.04 CHIMNEY C3 8271.57'CHIMNEY R1 8273.04'RIDGE R2 8267.17'RIDGE R3 8262.26'RIDGE AS-BUILT NOTES: 1) PIPES INSTALLED PER DESIGN ACCORDING TO STRUCTURAL ASSOCIATES. 1/11/20182/4/2021 Josh Rice 2/4/21 42764 12/18/2019 Reviewed by Engineering 02/10/2021 5:04:44 PM "It should be known that this review shall not relieve the applicant of their responsibility to comply with the requirements of the City of Aspen. The review and approval by the City is offered only to assist the applicant's understanding of the applicable Engineering requirements." The issuance of a permit based on construction documents and other data shall not prevent the City of Aspen from requiring the correction of errors in the construction documents and other data.