HomeMy WebLinkAboutFile Documents.395 Thunderbowl Ln.0255.2018 (36).ARBK395 Thunderbowl ‐ WELS Comments 02.12.2019 Written Responses 02.22.2019
Page: IR‐2.0 IRRIGATION PLAN
How will these native grass areas be irrigated; Note number 4 notwithstanding?
Response: Irrigation equipment relocated along property line to serve all native grass, note #4 removed.
Page: IR‐2.0 IRRIGATION PLAN
Trees should be on separate valves from shrubs, ground‐covers, and turf as per WELS Section 6.2.7 (5.2.7
in newer version). Revise plans in all cases.
Response: Dedicated tree irrigation provided to all trees within planting bed.
Page: IR‐2.0 IRRIGATION PLAN
WELS Section 6.1.3 (5.1.3 in newer version) requires a lockable master valve
Response: Lockable master valve & construction note included (Note #4)
Page: IR‐2.1 IRRIGATION PLAN‐ROOFTOP
Provide the reasoning for overhead spray irrigation versus subsurface on these two roof gardens. Also,
why is one side a medium water usage and the other side a low water usage when they appear to be
utilizing the same low water plants? Your hydrozone plan calls out green roofs as low water.
Response: Green roof planting material consists of a seed mix, which can be difficult to establish with
sub‐surface irrigation. All green roof irrigation indicated as Low water.
Page: L002 notes
Include all the language of WELS Section 5.3 (4.2 in newer version) regarding 4" mulch spec
Response: The language of WELS Section 4.2 regarding mulch has been added to the notes.
06/18/2019
Page: L401 site plan
There aren't any high water zones listed in your water budget worksheet. Revise plans accordingly.
Response: High water zones have been revised per water budget worksheet.
Page: L401 site plan
Where is the mowed native located on this plan?
Response: Mowed native hatch has been added to L401.
Page: L401 site plan
Trees should be medium water as per your water budget worksheet
Response: Trees have been revised to medium water.
Page: L401 site plan
Trees should not be planted within the 10‐ foot utility easement.
Response: Trees have been relocated from the 10’ utility easement.
Page: L401 site plan
Trees should not be planted over water main extension
Response: Trees have been adjusted to allow separation of root ball from water main extension.
06/18/2019