Loading...
HomeMy WebLinkAboutFile Documents.430 W Hallam St.0291.2017 (76).ARBKResidential Air Infiltration Test Report Test date:4/8/2024 Project name:430 W Hallam Address:430 W Hallam St Aspen Code:2015 IECC Conditioned volume:129,818 Cubic Feet Attic:unvented Crawlspace:conditioned Garage:excluded Measured airflow:1,645 CFM50 Cubic Feet per Minute at 50 Pascal Temperature; Inside:67 Temperature; Outside:28 Elevation:7,890 Corrected airflow:1,603 CFM50*Cubic Feet per Minute at 50 Pascal 2015 IECC maximum allowed leakage rate:3.0 ACH50 Air Changes Per Hour at 50 Pascal Tested air leakage rate:0.7 ACH50 Air Changes Per Hour at 50 Pascal Test code compliance:PASS Test notes: Tests were performed by Chris Taylor; Rated Field Inspector, RFIIN #CY5MPL * Test results have been corrected for elevation and air density temperature differential. NA