HomeMy WebLinkAboutFile Documents.430 W Hallam St.0291.2017 (76).ARBKResidential Air Infiltration Test Report
Test date:4/8/2024
Project name:430 W Hallam
Address:430 W Hallam St
Aspen
Code:2015 IECC
Conditioned volume:129,818 Cubic Feet
Attic:unvented
Crawlspace:conditioned
Garage:excluded
Measured airflow:1,645 CFM50 Cubic Feet per Minute at 50 Pascal
Temperature; Inside:67
Temperature; Outside:28
Elevation:7,890
Corrected airflow:1,603 CFM50*Cubic Feet per Minute at 50 Pascal
2015 IECC maximum allowed leakage rate:3.0 ACH50 Air Changes Per Hour at 50 Pascal
Tested air leakage rate:0.7 ACH50 Air Changes Per Hour at 50 Pascal
Test code compliance:PASS
Test notes:
Tests were performed by Chris Taylor; Rated Field Inspector, RFIIN #CY5MPL
* Test results have been corrected for elevation and air density temperature differential.
NA