HomeMy WebLinkAboutFile Documents.533 W Hallam St.0285.2018 (92).ARBK0285-2018-ARBK_BuildingComment2 Subject: PlanCheck Page: A801 ASSEMBLIES -FLOOR Author: justinh Color: File Name: Architectural - Comment Response Drawings.pdf If this is to be a pervious paver snowmelt system then you will need to drill holes through the rigid insulation in order for it to actually drain. If you are doing that then you must detail a hole pattern and call out the insulation thickness so that you still achieve a R10 weighted average with the holes in the insulation. This also applies to detail 11/A811. Discussion regarding this not being applicable only applied to the snowmelt systems over the basement where it wasn't actually a true pervious system and we relied on the roof insulation to meet the R10 requirement. Architectural - Comment Response Drawings.pdf (6) Subject: PlanCheck Page: A802 ASSEMBLIES -EXTERIOR WALL Author: justinh Color: File Name: Architectural - Comment Response Drawings.pdf Providing the visqueen vapor barrier on the outside of the existing historic wall assemblies with painted gypsum board on the interior will most likely trap moisture within the wall assembly because the wall cannot dry in either direction now (latex paint on gypsum board creates another vapor barrier on the interior side). I cannot require it to be removed, but we do suggest it. I apologize if my original comment confused the issue. I wasn't trying to state that you had to provide waterproofing or a vapor barrier behind the existing historic siding, I just wanted the detail to be accurate to what you're actually able to do given the historic restrictions on that structure. Subject: PlanCheck Page: A802 ASSEMBLIES -EXTERIOR WALL Author: justinh Color: File Name: Architectural - Comment Response Drawings.pdf The new walls need to meet current energy code requirements, regardless of whether they are being sided to match existing historic siding. The existing building code exceptions do not apply to newly constructed walls. Revise to provide compliant insulation as you show in W-9. INTERIOR CEILING FINISHREF. INTERIOR FINISH SCHEDULECEILING HEIGHT, REF. REFLECTED CEILING PLANS 3/4" WOOD FLOORING,REF. INTERIOR FINISH SCHEDULE GYPCRETE 1 1/2" MIN. FLOOR FRAMINGREF. STRUCTURAL T.O.FIN RADIANT HEAT SYSTEMREF. MECHANICAL INTERIOR SHEATHINGREF. STRUCTURAL 1/8" SOUND MAT & ADHESIVE 5/8" GYPSUM BOARD(TYPE "X" GWB @ GARAGE ) T.O.SHTHGREF. PLAN3" 5/8" SHEATHING VARIES BLOW - IN SOUND ATTENUATION INSULATION2X UNDER FRAMING SOUND BATT INSULATION INTERIOR CEILING FINISHREF. INTERIOR FINISH SCHEDULECEILING HEIGHT, REF. REFLECTED CEILING PLANS MORTAR BED T.O.FIN INTERIOR GYPCRETE 1 1/2" MIN. SHEATHINGREF. STRUCTURAL NOTE: REFER TO TCNA GUIDELINESFOR TILE INSTALLATION RADIANT HEAT SYSTEMREF. MECHANICAL FLOOR FRAMING REF. STRUCTURAL UNCOUPLING MEMBRANE 5/8" GYPSUM BOARD (TYPE "X" GWB @ LOWER LEVEL FLOOR) T.O.SHTHGREF. PLAN3" VARIES BLOW - IN SOUND ATTENUATION INSULATION2X UNDER FRAMING SOUND BATT INSULATION T.O. FINREF. PLAN PATIO ENGINEERED FILL GRAVEL CONCRETE PAVERS TO MATCH APPROVED SAMPLE COMPACTED SANDRADIANT TUBING FILTER FABRIC -HYDRODRAIN AL RIGID INSULATIONR-10 MIN. 4" MIN.4" 3"1/4"2"2" 10/8/201 9 3 : 3 4 : 1 6 P M SCALE1 1/2" = 1'-0"F-7 WOOD FLOOR @ MAIN LEVEL SCALE1 1/2" = 1'-0"F-8 STONE TILE FLOOR @ MAIN LEVEL SCALE1 1/2" = 1'-0"F-10 PATIO PAVERS @ GRADE If this is to be a pervious paver snowmeltsystem then you will need to drill holesthrough the rigid insulation in order for it toactually drain. If you are doing that thenyou must detail a hole pattern and call outthe insulation thickness so that you stillachieve a R10 weighted average with theholes in the insulation. This also applies todetail 11/A811. Discussion regarding this not beingapplicable only applied to the snowmeltsystems over the basement where it wasn'tactually a true pervious system and werelied on the roof insulation to meet the R10requirement. COMPOSITE METAL PANEL PER MFR. INTERIOR EXTERIORPER PLAN 1 5/8"1 1/2" 3 1/8" LE INTERIOR FINISHREF. INTERIOR FINISH SCHED WEATHER RESISTIVE BARRIER DRAINAGE MAT SPRAYED FOAM INSULATION(R-20 MIN.) 2X WOOD FRAMING, REF STRUCTURAL 5/8" GYPSUM BOARD INSULATED SHEATHING PANEL (R-5 MIN.)HORIZ. CHANNEL LAP WOOD SIDING 3/4"1/4"1 1/2" INTERIOR EXTERIOR PER PLAN5/8" 8 5/8" 3/4" 1/2" 9 7/8" R-20 + 5 1/2" PLYWOOD SHEATHING, R STRUCTURAL (SIM) REFERENCE STRUCTURAL INTERIOR FINISHREF. INTERIOR FINISH SCHEDULESPRAYED FOAM INSULATION(R-20 MIN.) 2X WOOD FRAMINGREF. STRUCTURAL 5/8" GYPSUM BOARD NEW WOOD SIDING TO MATCH EXISTING (PAINT PER APPROVED SAMPLE) INTERIOR EXTERIOR INSULATED SHEATHING PANEL (R-5 MIN.) R-20 + 5 WEATHER RESISTIVE BARRIE 5 1/2"1" DRAINAGE MAT INTERIOR FINISH 5/8" GYPSUM BOARDEXTERIOR 5/8"1/2"3 1/2"1/2"1/4"1" 4" INTERIOR FINISHREF. INTERIOR FINISH SCHEDULE BATT INSUALTION (HIGH DENSITY)(R-15 MIN.) EXISTING WOOD FRAMING, REF STRUCTURAL 5/8" GYPSUM BOARD EXISTING WOOD SIDING TO MATCH EXISTING (PAINT PER APPROVED SAMPLE) INTERIOR EXTERIOR R-15 SISTERED 2 X 4 FRAMING LINE OF 2 X 4 FRAMING VISQUEEN VAPOR BARRIER 5/8"3 1/2"1/2"4" SCALE3" = 1'-0"W-8 WOOD CHANNEL LAP SIDING WALL SCALE3" = 1'-0"W-9 NEW HISTORIC WOOD SIDING WALL SCALE3" = 1'-0"W-11 EXISTING HISTORIC WOOD SIDING WALL Providing the visqueen vapor barrier onthe outside of the existing historic wallassemblies with painted gypsum boardon the interior will most likely trapmoisture within the wall assemblybecause the wall cannot dry in eitherdirection now (latex paint on gypsumboard creates another vapor barrier onthe interior side). I cannot require it to beremoved, but we do suggest it. Iapologize if my original commentconfused the issue. I wasn't trying tostate that you had to providewaterproofing or a vapor barrier behindthe existing historic siding, I just wantedthe detail to be accurate to what you'reactually able to do given the historicrestrictions on that structure. COMPOSITE METAL PANEL PER MFR. WEATHER RESISTIVE BARR COMPOSITE METAL PANEL HANGERS PER MFR SPRAYED FOAM INSULATIO (R-20 MIN.) 2X WOOD FRAMING, REF STRUCTURALINTERIOR FINISHREF. INTERIOR FINISH SC INSULATED SHEATHING PANEL (R-5 MIN.) ACCENT STRIP PANEL FASTENER PANEL ATTACHMENT CLIP INTERIOR EXTERIORPER PLAN 1 5/8"1 1/2" 3 1/8" PANEL MODULE 1/2" PANEL MODULE R-20 + 5/8" GYPSUM BOARD 2X WOOD FRAMING, REF STRUCTURAL R-20 + 1/2" PLYWOOD SHEATHIN STRUCTURAL (SIM) REFERENCE STRUCTURAL INTERIOR FINISHREF. INTERIOR FINISH SCHEDULE BATT INSULATION (HIGH DENSITY)(R-15 MIN.) 2X WOOD FRAMINGREF. STRUCTURAL 5/8" GYPSUM BOARD NEW WOOD SIDING TO MATCH EXISTING (PAINT PER APPROVED SAMPLE) INTERIOR EXTERIOR 1/2" SHEATHING R-15 WEATHER RESISTIVE BARRIER 5/8"1/2"3 1/2"1/2"1/4"1" DRAINAGE MAT (SIM) REFERENCE STRUCTURAL 1/2" PLYWD. (OMIT EXTRA LAYER OF PLYWD. IF IT IS NOT NEEDED TO ALIGN WITH HISTORIC WALLS) 4" EXISTING WOOD FRAMING, REF STRUCTURAL R-15 SISTERED 2 X 4 FRAMING 10/8/ 2 0 1 9 3 : 3 4 : 2 0 P M SCALE3" = 1'-0"W-7 METAL PANEL SIDING WALL SCALE3" = 1'-0"W-8 WOOD CHANNEL LAP SIDING WALL SCALE3" = 1'-0"W-10 NEW HISTORIC WOOD SIDING WALL SCALE3" = 1'-0"W-11 EXISTING HISTORIC WOOD SIDING WALL The new walls need to meetcurrent energy coderequirements, regardless ofwhether they are being sided tomatch existing historic siding. The existing building codeexceptions do not apply to newlyconstructed walls. Revise toprovide compliant insulation asyou show in W-9. ARCHITECTURAL RESPONSE 02/24/20 THE VISQUEEN HAS BEEN REPLACED WITH A WEATHER RESISTIVE BARRIER ON DETAIL W-11/A802 WHICH IS NOW W-13/A803 AS WELL AS DETAILS WS-4 & 6. ALSO THE FOLLOWING NOTE HAS BEEN ADDED TO THE DETAILS: "HPC IS WORKING TO DEVELOP A STANDARD DETAIL FOR THIS SITUATION. WE WILL WORK WITH THEM AND UPDATE THIS DETAIL AS THEIR INFORMATION BECOMES ABVAILABLE. DO NOT CONSTRUCT THIS WALL WITHOUT SIGN OFF FROM THE ARCHITECT AND HPC." DETAIL W-10/A802 HAS BVEEN REVISED TO MEET CURRENT ENERGY CODE. LOCATION NOW IS DETAIL W-12/A803. DETAIL F-10/A801 HAS BEEN REVISED AND IS NOT TO BE CONSIDERED PERVIOUS PER OUR DICUSSION, 02/28/2020 Subject: PlanCheck Page: A812 DETAILS -EXTERIOR Author: justinh Color: File Name: Architectural - Comment Response Drawings.pdf Provide the waterproofing drawings that you are referencing on almost every foundation detail. Subject: PlanCheck Page: A901 INTERIOR & EXTERIOR DOOR SCHEDULE W/ DOOR Author: justinh Color: File Name: Architectural - Comment Response Drawings.pdf Provide the weighted average documentation you reference. Subject: PlanCheck Page: G011 RREMP PLAN Author: justinh Color: File Name: Architectural - Comment Response Drawings.pdf You have an error in the REMP total area number you show (1092-36=1056 not 1065). Revise your second total. Subject: PlanCheck Page: 1 Author: justinh Color: File Name: Building Comment 1 - Architectural Response.pdf You've made that note at 2 of the flat roofs, but there is no such note on the flat roofs on the non-historic addition. Clearly note that requirement on all flat roof sections so that there is no confusion as to how you are meeting that requirement. The largest flat roof on the addition is more than 8' from the inlet to the edge in the long dimension that is called out as being 1/4" per foot slope, which would mean that edge will be greater than 2" above the drain inlet. Revise or clarify how you intend to provide compliant secondary drainage at that specific flat roof. Building Comment 1 - Architectural Response.pdf (3) W-1 T.O. CONC.100' - 6" MIN. 6" EXPANSION JOINT NOTE:REF. WATERPROOFING DRAWINGS FOR WATERPROOFING DETAILS SIM T.O. FIN. FLR @ GARAGE100' - 2" 1 1/2 T.O. WALL99' - 6 3/4" PRESSURE TREATED PLATE W/ CAPILLARY BREAK (TYP.) Provide the waterproofingdrawings that you arereferencing on almostevery foundation detail. T.O. SHTHG @ MAIN LEVEL EXTERIOR2' - 6"INTERIOR2' - 6" DOOR DIMENSIONS GENERAL NOTES 1)REFERENCE FLOOR PLANS FOR DOOR HANDING. NOTIFY ARCHITECT OF ANY DISCREPENCIES. 2)REFERENCE ELEVATIONS FOR WINDOW HANDING AND OPERATION. NOTIFY ARCHITECT OF ANY DISCREPENCIES. 3)ALL WINDOWS AND DOORS TO HAVE "LOW E" INSULATED GLAZING U.N.O. THEY SHOULD ALSO BE RATED FOR HIGH ALTITUDES, PER MANUFACTORER'S SPECIFICATION. 4)PROVIDE WEATHERSTRIPPING AND ALUMINUM THRESHOLDS FOR ALL EXTERIOR DOORS, U.N.O. 5)VERIFY WINDOW AND DOOR HARDWARE FINISHES WITH OWNER PRIOR TO ORDERING. 6)TEMPERED GLASS MUST BE PROVIDED IN ALL HAZARDOUS AREAS PER SECTION R308 2015 IRC. 7)ALL WINDOWS TO COMPY WITH 2015 IECC CHAPTER 4, CLIMATE ZONE 7 & 8, FENESTRATION U-FACTOR 0.28. WINDOW MANUFACTORER TO PROVIDE DOCUMENTATION FOR THE WINDOW PACKAGE DEMONSTRATING A WEIGHTED AVERAGE OF U-VALUE 0.28 AND STICKER MARKING OF UNITS FOR APPROVAL BY THE CITY OF ASPEN BUILDING DEPARTMENT. 8) INDICATES SAFETY GLASS. 9) INDICATES EGRESS. 10)R.O.'S ARE 1/2" BEYOND OVERALL FRAME DIMENSIONS. 11)FIELD VERIFY ALL R.O. DIMENSIONS BEFORE ORDERING. 12)PROVIDE SCREENS FOR OPERABLE WINDOWS. COORDINATE WITH ARCHITECT. 13)SEE REFLECTED CEILING PLANS FOR REFERENCED SHADE POCKET DETAILS & DESCRIPTION. T E SHEE THE INF PROPER NO PAR c2 PROJ DU 533 A INT DO TY 2170 Provide the weightedaveragedocumentation youreference. SNOWMELTED AREAS SNOWMELTED AREAS IN R.O.W. ON SEPERATE ZONE 15.33 SF 56.71 SF 16.00 SF30.19 SF 44.75 SF51.44 SF 1,092.06 SFAREAS TOTAL THE CITY ALLOWS A 9 SF REDUCTION IN CALCULATED AREA AT EACH LIGHTWELL. 9 SF X 4 = 36 SF 1,092.06 SF -36 SF = 1,056.06 SF REMP TOTAL AREA 1,065.06 SF Consultant ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 Issue: 1 02.04.2019 PRELIMINARYPRICING 2 05.28.2019 PRICING SET 3 07.16.2019 UPDATEDPRICING4 09.06.2019 COMMENTRESPONSE 5 10.09.2019 COA COMMENT RESPONSE You have an error inthe REMP total areanumber you show(1092-36=1056 not1065). Revise yoursecond total. Subject: PlanCheckPage Label: A101Author: justinhFile Name: Architectural Plans. 533 W HALLAM.pdfColor: Identify patio materials, there isa detail for permeable paversand the site plan should clearlyshow where this is proposed. Subject: PlanCheckPage Label: A203Author: justinhFile Name: Architectural Plans. 533 W HALLAM.pdfColor: Show all electrical panellocations on your architecturalfloor plans. Subject: PlanCheckPage Label: A205Author: justinhFile Name: Architectural Plans. 533 W HALLAM.pdfColor: Show your radon mitigationsystem termination pipe on theroof plan along with any otherventing that is not currentlyshown. Subject: PlanCheckPage Label: A205Author: justinhFile Name: Architectural Plans. 533 W HALLAM.pdfColor: Show compliant secondary roofdrainage per IRC 903.4.1, eitherscuppers or secondary drains. Ifsecondary drains are used theymust discharge to a differentlocation than the primary drainswhere they will be observed bythe building occupant per IPC1108.2. 14 10' SETBACK N14°50'49"E 100.00' 100' - 0" LIGHT WELL LIGHT WELL LIGHT WELL LIGHT WELL BELOWBELOWBELOWBELOW V.I.F. SETBACK10' - 0"PROPOSED 36" FENCE LINE OF NO FOUNDATION / DIGGING ESTABLISHED BY PARKS IN PERSON MEETING ON 06.19.2018 Identify patio materials,there is a detail forpermeable pavers andthe site plan shouldclearly show wherethis is proposed. A PROP E R T Y L I N B 4' - 6" 6" 12' - 2 3 / 8 " Show all electrical panel locations onyour architectural floor plans. NE OF OW Show your radon mitigationsystem termination pipe on theroof plan along with any otherventing that is not currently shown. Show compliant secondary roof drainage perIRC 903.4.1, either scuppers or secondarydrains. If secondary drains are used theymust discharge to a different location than theprimary drains where they will be observed bythe building occupant per IPC 1108.2. You've made that note at 2 of the flat roofs, butthere is no such note on the flat roofs on thenon-historic addition. Clearly note thatrequirement on all flat roof sections so thatthere is no confusion as to how you aremeeting that requirement. The largest flat roof on the addition is morethan 8' from the inlet to the edge in the longdimension that is called out as being 1/4" perfoot slope, which would mean that edge will begreater than 2" above the drain inlet. Reviseor clarify how you intend to provide compliantsecondary drainage at that specific flat roof. WATERPROOFING DRAWINGS ARE ATTACHED TO THIS RESPONSE. THE U-VALUE WEIGHTED AVERAGE DOCUMENTATION IS ATTACHED TO THIS RESPONSE. THE U-VALUES WERE ADDED TO THE SCHEDULES ON THE DRAWINGS. THE REMP TOTAL AREA HAS BEEN REVISED TO 1056. THE LARGEST FLAT ROOF HAS BEEN REVISED PROVIDING 2 ROOF DRAINS AND ADDED THE NOTE CALLING OUT 1/4" PER FOOT SLOPE AND THAT THE EDGE OF ROOF IS NOT MORE THAN 2" ABOVE THE ROOF DRAIN. ALSO THE REMAINING FLAT ROOFS HAVE BEEN NOTED AS WELL. 02/28/2020 Weighted average and schedule are good. Please verify that these windows will be NFRC stickered at inspection and add a note stating that to the window schedule. Subject: PlanCheck Page: 2 Author: justinh Color: File Name: Building Comment 1 - Architectural Response.pdf You are not showing any utility meters on the east elevation, which is where they should be per the main level floor plan. Comment unresolved. Subject: PlanCheck Page: 4 Author: justinh Color: File Name: Building Comment 1 - Architectural Response.pdf If you are proposing to protect from decay by using treated lumber, waterproofing a minimum of 6" above grade, and a capillary break you need to also use treated sheathing within 6" of grade to fully protect the wall framing that is less than 6" above grade. ZIP panels (which is what I'm assuming you are referring to when your details call out insulated sheathing) are not approved to be installed less than 6" above grade per the manufacturer, what you propose does not work. Comment unresolved. Revise details to comply with R404.1.6 by either raising the height of the foundation walls, revising exterior grade, or calling out treated sheathing for the first course above grade in addition to the other notes you added. Structural should be updated to allow and/or note the requirements for pressure treated sheathing for the first course. Subject: PlanCheck Page: 7 Author: justinh Color: File Name: Building Comment 1 - Mechanical Response.pdf Are you still planning on using an approved fabricator for shop welds as this response implies, or will you be using custom structural steel as an inspected fabricator for both shop and field welds. Please clarify, I can accept either but any shop welds done by the inspected fabricator must still be inspected by your special inspector. Building Comment 1 - Mechanical Response.pdf (1) Subject: PlanCheckPage Label: A404Author: justinhFile Name: Architectural Plans. 533 W HALLAM.pdfColor: Please dimension the height andopening size on your guard toshow compliance with IRC 312 Subject: PlanCheckPage Label: A404Author: justinhFile Name: Architectural Plans. 533 W HALLAM.pdfColor: Please show utility meters onyour elevations. Subject: PlanCheckPage Label: A702Author: justinhFile Name: Architectural Plans. 533 W HALLAM.pdfColor: Show a compliant handrail andguard on the lower level stairs. Subject: PlanCheckPage Label: A702Author: justinh Please add dimensions to showthat both the guard and open 04 03 GUARDRAIL PER CODE LIGHTWELL Please dimension theheight and openingsize on your guard toshow compliance withIRC 312 04 DRYER VENTUARDRAIL PER CODE LIGHTWELL Please show utilitymeters on yourelevations. T.O. F.F. @ MAIN100' - 0" T.O. F.F. @ UPPER110' - 4 1/2" T.O. PLY @ MAIN99' - 9" T.O. PLY @ UPPER110' - 1 1/2"6' - 8"MIN. HEAD HEIGHT MIN. HEAD HEIGHT 10 3/4"7" T.O. PLY @ BASEMENT86' - 4"T.O. F.F. @ BASEMENT86' - 7" T.O. CONC. @ CRAWL SPACE79' - 6 3/8" 6' - 8"6' - 8" 3' - 0" 001FAMILY /FAMILY /FAMILY /FAMILY /GAMEGAMEGAMEGAME M01MECHANICALMECHANICALMECHANICALMECHANICALCRAWLSPACECRAWLSPACECRAWLSPACECRAWLSPACE 106LIVINGLIVINGLIVINGLIVING STAIRSTAIRSTAIRSTAIR MECHANICAL ACCESS HATCH 6' - 8"MIN. HEAD HEIGHT MIN. HEAD HEIGHT 11 3/4"7" 6' - 8" M01MECHANICALMECHANICALMECHANICALMECHANICALCRAWLSPACECRAWLSPACECRAWLSPACECRAWLSPACE STAIRSSTAIRSSTAIRSSTAIRS STAIRSSTAIRSSTAIRSSTAIRS 004STO.STO.STO.STO.001FAMILY /FAMILY /FAMILY /FAMILY /GAMEGAMEGAMEGAMEANICAL S HATCH SCALE 1/4" = 1'-0"1STAIR SECTION - NORTHSOUTH Show a complianthandrail and guard onthe lower level stairs. ELEVCSTAIRSTAIRSTAIRSTAIR You are not showingany utility meters onthe east elevation,which is where theyshould be per themain level floor plan. Comment unresolved. Subject: PlanCheckPage Label: A812Author: justinhFile Name: Architectural Plans. 533 W HALLAM.pdfColor: Revise all drawings(architecturals, structurals, civils)so grade is 6” or more below thetop of each foundation wall per2015 IRC R404.1.6 (clearlydimensioned in the architecturaldetails). Alternatively, the Citywill accept a lesser distance if allof the following are provided.Note this requirement at allapplicable wall sections anddetails:1.All wood materials within 6” ofgrade to be protected fromdecay per R317.1 5.2.Waterproof membraneextending up wall a minimum of6” above grade.3.Capillary break separatingconcrete from wood materials.If you go that route you will alsoneed to have the structural planrevised to show treated lumberas a specified material and havethem list the proper fasteners fortreated wood as the chemicalsused to treat lumber candegrade typical fasteners. Subject: PlanCheckPage Label: A815Author: justinhFile Name: Architectural Plans. 533 W HALLAM.pdfColor: Indicate how you will accomplishthe air sealing requirements of2015 IECC table R402.4.1.1using notes and details. Indicatethe continuity of the air barrierand where it is locatedthroughout the building. Notelocations that require caulking,sealing, taping, etc. Note whichcomponents are included in theair barrier such as spray foam,gypsum, housewrap, and/orexterior insulation. You mayhave all of the above but youneed to pick one continuousbarrier and stick to it. It needs tofollow the thermal barrier. Thebetter detail you provide, theeasier it will be for the contractorand inspector to be successful.This is a new 2015 coderequirement in lieu of a blowerdoor test. I've attached ourstandard air sealing detail sheetsto this comment letter as an W-1T.O. CONC. @ CRAWL SPACE79' - 6 3/8"F-1 WATERPROOFINGHYDRODUCT COIL 600WRAP HYDRODUCT 220 PERMANUFACTURER'S RECOMMENDATIONS.PER STRUCT.PER STRUCT.T.O. CONC. @ BASEMENT83' - 2"F-1W-2SIM MECHANICAL VOID SPACEPER STRUCT.EXPANSION JOINTHYDRODUCT 220HYDRODUCT COIL 600PER STRUCT.REFERENCE SOIL RETENSION PLANS FOR SYSTEM TO USEAT.O. PLY @ MAIN99' - 9"B T.O.F.F. @ PATIO & GARAGE99' - 11"R-1R-4 WOOD CLAD STEEL COLUMN.PAINT TO MATCH SIDING.KEEP WOOD 1" UP FROM FIN. GRADE1"COLUMN BASE PER STRUCTURALWATERPROOFING PER WJECONCRETE DECKING PER STRUCTURALMICROPILE WALL DEMO CAP AS NECESSARY. VERIFY LOCATIONS WITH ENGINEER.STEEL PER STRUCTURALPER STRUCTURAL T.O. F.F. @ MAIN100' - 0"AT.O. PLY @ MAIN99' - 9"B W-2 EXISTING HISTORIC STUDS AND SIDING VIF LOCATION AND CONNECTION TO NEW STRUCTURAL FOOTING WITH ARCHITECT AND STRUCTURAL ENGINEER DURING DEMO PHASE. W-111/2" DENSGLASS BACKER OVER WATERPROOFING.CONCRETE SCRACTH COAT TO MATCH EXISTING CONDITION. VIF COLOR WITH ARCHITECT.PROPOSED GRADE TO MATCH RELATIONSHIP OF EXISTING GRADE TO HISTORIC HOUSE. REF CIVIL AND GRADING PLANRIGID INSULATION3"DRAINAGE MATCONTINUE SPRAY INSULATION UP TO THE BOTTOM OF SHEATHING (TYP) T.O. F.F. @ MAIN100' - 0"LKT.O. PLY @ MAIN99' - 9"METAL FLASHING CONTINUOUSUNDER WINDOW 1/2" DENSGLASS OVER ZIP PANELFOR PROTECTION.WATERPROOFING PER WJECONCRETE TOPPING SLOPED 1/4" PER FOOTCONTINUE SPRAY FOAM INSULUP TO UNDERSIDE OF SHEATHING(TYP)CONCRETE PER STRUCTURALW-3PER STRUCT.PER STRUCT. 10 T.O. PLY @ MAIN99' - 9"T.O.F.F. @ PATIO & GARAGE99' - 11"F-2 EXPANSION JOINTCONC FILL AS NECESSARY VIF WITH STRUCTURALALLEY GRAVELCONCRETE DRIVE UP FROM PROPERTY LINE TO GARAGE ENTRY. GARAGE DOOR MICROPILE WALLPER STRUCT.STEEL PER STRUCTURALSTEEL DECKING AND GARAGE CONC PERSTRUCTURAL LKT.O. PLY @ MAIN99' - 9"T.O.F.F. @ PATIO & GARAGE99' - 11"F-2 W-1 W-7METAL FLASHING CONTINUOUSUNDER DRAINAGE MAT AND OVER FOUNDATION INSULATIONMETAL FLASHING WITH DRIP EDGE COLOR TO MATCHSIDINGCONTINUOUS METALFOUNDATION FLASHING. POWEDER COAT TO MATCHMETAL PANNEL SYSTEM. SELF ADHERED FLASHINGTO OVERLAP ALL METAL FLASHING PER STRUCT.PER STRUCT.STEEL PER STRUCTURAL T.O. F.F. @ MAIN100' - 0"C T.O. PLY @ MAIN99' - 9"T.O.F.F. @ PATIO & GARAGE99' - 11"R-1SELF ADHERED FLASHINGTO OVERLAP ALL METAL FLASHINGMETAL FLASHING CONTINUOUSUNDER DRAINAGE MAT AND OVER FOUNDATION INSULATIONMETAL FLASHING WITH DRIP EDGE COLOR TO MATCH SIDING. W-7WATERPROOFING PER WJE3" RIGID INSULATION1/2" DENSGLASSCONC PER STRUCTURALSTEEL PER STRUCTURALT.O. F.F. @ MAIN100' - 0"T.O. PLY @ MAIN99' - 9"W-7SIM W-1 SELF ADHERED FLASHINGTO OVERLAP ALL METAL FLASHINGMETAL FLASHING CONTINUOUSUNDER DRAINAGE MAT AND OVER FOUNDATION INSULATIONMETAL FLASHING WITH DRIP EDGE COLOR TO MATCHSIDINGFLOOR FRAMING. REF STRUCT.CONTINUOUS METALFOUNDATION FLASHING. POWEDER COAT TO MATCHMETAL PANNEL SYSTEM. AT.O. F.F. @ UPPER110' - 4 1/2"T.O. PLY @ UPPER110' - 1 1/2"F-3W-7METAL FLASHING W/ DRIP EDGE,COLOR TO MATCH SIDINGWOOD FASCIA TO MATCH SIDINGCONTINUOUS SPRAY FOAM INSULATION STEEL BEAM, REF. STRUCT.SAW-CUT DRIP EDGE WOOD WRAPPED COLUMNSELF-ADHERED FLASHING TO OVERLAP METAL FLASHINGWEATHER RESISTANT BARRIER SCALE 1 1/2" = 1'-0"A8124DTL_Foundation @ Office West SCALE 1 1/2" = 1'-0"A8126FOUNDATION WALL @ STAIR HALL SCALE 1 1/2" = 1'-0"A8127DTL_Foundation Wall @ Garage DoorSCALE 1 1/2" = 1'-0"A8128FOUNDATION WALL @ GARAGE SLAB - EAST SCALE 1 1/2" = 1'-0"A8129PATIO @ EXTERIOR WALLSCALE 1 1/2" = 1'-0"A81210TYPICAL FOUNDATION WALL @ WOOD JOIST SCALE 1 1/2" = 1'-0"A8125COLUMN @ MASTER BATHRevise all drawings (architecturals, structurals, civils) sograde is 6” or more below the top of each foundation wallper 2015 IRC R404.1.6 (clearly dimensioned in thearchitectural details). Alternatively, the City will accept alesser distance if all of the following are provided. Note thisrequirement at all applicable wall sections and details:1.All wood materials within 6” of grade to be protected fromdecay per R317.1 5.2.Waterproof membrane extending up wall a minimum of 6”above grade.3.Capillary break separating concrete from wood materials.If you go that route you will also need to have the structuralplan revised to show treated lumber as a specified materialand have them list the proper fasteners for treated wood asthe chemicals used to treat lumber can degrade typicalfasteners. Indicate how you will accomplish the air sealingrequirements of 2015 IECC table R402.4.1.1 usingnotes and details. Indicate the continuity of the airbarrier and where it is located throughout the building.Note locations that require caulking, sealing, taping, etc.Note which components are included in the air barriersuch as spray foam, gypsum, housewrap, and/orexterior insulation. You may have all of the above butyou need to pick one continuous barrier and stick to it. Itneeds to follow the thermal barrier. The better detail youprovide, the easier it will be for the contractor andinspector to be successful. This is a new 2015 coderequirement in lieu of a blower door test. I've attachedour standard air sealing detail sheets to this commentletter as an example of the type of detailing we'relooking for. If you are proposing to protect from decay byusing treated lumber, waterproofing a minimumof 6" above grade, and a capillary break youneed to also use treated sheathing within 6" ofgrade to fully protect the wall framing that isless than 6" above grade. ZIP panels (which iswhat I'm assuming you are referring to whenyour details call out insulated sheathing) arenot approved to be installed less than 6" abovegrade per the manufacturer, what you proposedoes not work. Comment unresolved. Revise details to complywith R404.1.6 by either raising the height of thefoundation walls, revising exterior grade, orcalling out treated sheathing for the first courseabove grade in addition to the other notes youadded. Structural should be updated to allow and/ornote the requirements for pressure treatedsheathing for the first course. Subject: PlanCheckPage Label: 8Author: justinhFile Name: Mechanical Plans. 533 W HALLAM.pdfColor: Snowmelt square footagesshown here and on thesnowmelt schedule do not matchwhat is shown on thearchitectural REMP sheet. Revise one or the other so thatthe snowmelt quantities andlocations are consistent. Youmay exempt 9 SF of snowmeltfor each window well (minimumsize required for an emergencyescape egress well) but youmust include any additionalsquare footage for each windowwell in your REMP calculation. Subject: PlanCheckPage Label: 1Author: justinhFile Name: RREMP Documents.533 W Hallam.pdfColor: Please fill out the contact infoportion of this form. If the siteplan/REMP plan are revised perdiscussions with HPC andbuilding regarding the light wellguards, please be sure to updatethe square footages on thissheet accordingly. RREMP Documents.533 W Hallam.pdf (1) Subject: PlanCheckPage Label: 3Author: justinhFile Name: Special Inspection Agreement.533 W Hallam.pdfColor: You need an approvedfabricator's signature for theshop welds shown in thestructural plans. Pleaseresubmit the agreement. Youmay resubmit responses withoutthis if you have yet to decide onyour welder/steel fabricator butbuilding will not be able to signoff on your permit until thisagreement has been fullyexecuted. Special Inspection Agreement.533 W Hallam.pdf (1) Subject: PlanCheckPage Label: 1Author: justinhFile Name: Structural Plans. 533 W HALLAM.pdfColor: Our wind speed design criteria is89 MPH, please revise. Structural Plans. 533 W HALLAM.pdf (3) S T TT T T T 2 2 5 5 6 6 7 7 8 8 9 9 10 10 LLKKJJ FFGGDDCCAA3 3 4 4 EEHH 1 1 BB 5BRZ30 SQFT 7ARZ435 SQFT7BRZ125 SQFT 6BRZ35 SQFT 6ARZ1050 SQFT5ARZ495 SQFT8RM 9RM 7RMGARAGE103 MUD ROOM102ENTRY101 LIVING106 STAIR73STAIRS49PDR105 KITCHEN107 CASUAL DINING109ENTRY HALL110ENTRY111DINING113 OFFICE114 BIKES104 1/2"ø HWS1/2"ø HWR3/4"ø HWR UP3/4"ø HWS UP3/4"ø HWS1"ø HWR3/4"ø HWS3/4"ø HWR1"ø HWS DN1"ø HWR DN 1SZ635 SQFT2SZ235 SQFT 3SZ185 SQFT5SZ10 SQFT 4SZ30 SQFT3SM 2 31 45 TO FC-4 &RZ-6A TO FC-5,MD-5B &RZ-7ATO FC-5,MD-5A &RZ-7B TO RZ-5B TO RZ-5A TO RZ-6B www.aec-vail.com of Drawn By:Checked By:AEC PROJECT #: COPYRIGHT 2018 ARCHITECTURAL ENGINEERING CONSULTANTS, INC.c caePO Box 8489, 40801 US Hwy 6 & 24, Ste 214, A v o n , C o lorado, 81620 Mechanical, Electrical & Lighting Des i g n S e r v i c e s Architectural Engineering C o n s u l t a n t s Telephone: 970-748-8520 Fax: 97 0 - 7 4 8 - 8 5 2 1 An Office with LEED™ Accredited P r o f e s s i o n a l s DATE: ISSUE: SCALE 1/4" = 1'-0" 18032.00DUNCAN S K I H A U S 533 WEST HALLAM ASPEN, COLOR A D O , 8 1 6 1 1 M-122FIRST FLOORMECHANICALPIPING1014 BLUTOC11/23/18PERMIT/PRICING 1/4" = 1'-0"1MECHANICAL PIPING - 1ST FLOOR SHEET NOTES:1 CONNECT 1/2" SMS/R TO SM-3.2 CONNECT 1/2" HWS/R TO RM-9.3 CONNECT 3/4" HWS/R TO RM-8.4 CONNECT 3/4" HWS/R TO RM-7.5 INSTALL SNOW & ICE SENSOR IN THE SNOWMELT ZONE AS SHOWN.COORDINATE EXACT LOCATION WITH G.C. ENSURE THE SENSOR ISEQUIDISTANT BETWEEN TUBING & NOT UNDER OVERHANGS OR INWIND EDDIES.6 SEE ARCH SITE PLAN FOR CONTINUATION1. OFFSET PIPING AS REQUIRED TO AVOID ALL DUCTWORK, LIGHTS, AND STRUCTURE. COORDINATE ALL STRUCTURAL PENETRATIONS WITH THE STRUCTURAL ENGINEER.2. ALL PIPING PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL INCLUDE A FIRE-RATED PIPE SEALANT RATED TO MATCH THAT OF THE ASSEMBLY.3. VERIFY FINAL LOCATIONS OF ALL MANIFOLDS WITH THE G.C. CONTACT ENGINEER IF MANIFOLDS MOVE MORE THAN 10' FROM LOCATIONS SHOWN ON PLANS.4. LOCATION OF ALL THERMOSTATS AND FLOOR SENSORS ARE APPROXIMATE, COORDINATE EXACT LOCATIONS WITH THE ARCHITECT. LOCATE FLOOR SENSORS EQUIDISTANT BETWEEN RADIANT LOOPS, AND DO NOT LOCATE WHERE THEY MAY LIKELY BE COVERED BY FUTURE RUGS OR FURNITURE.5. ALL PIPING SIZED FOR TYPE L COPPER. CONTACT ENGINEER FOR ANY CHANGE TO PEX FOR NECESSARY PIPE SIZING AND/OR PUMP CHANGES.6. INSULATE ALL PIPE LEADERS PASSING THROUGH ADJACENT ZONES.GENERAL NOTES: Snowmelt square footages shown here andon the snowmelt schedule do not matchwhat is shown on the architectural REMPsheet. Revise one or the other so that thesnowmelt quantities and locations areconsistent. You may exempt 9 SF ofsnowmelt for each window well (minimumsize required for an emergency escapeegress well) but you must include anyadditional square footage for each windowwell in your REMP calculation. PROJECT ADDRESS:Parcel ID #: Permit Number: CONTACT INFORMATION :Owner:Name:City:Address:State:Email:Zip Code:Phone: Cell Phone:Owner's Representative :Name:City:AspenAddress:State:ColoradoEmail:Zip Code:81611Phone: Cell Phone:`A.RESIDENTIAL RENEWABLE ENERGY MITIGATION PROGRAMSheets showing snowmelt, pool, spa, and solar/GSHP information: Do you have snowmelt or a spa that has been exempted by the buiding official?Hydro SnowmeltElectric Snowmelt Pool SpaExisting0.00 sqft 0.00 sqft 0.00 sqft 0.00 sqftTo be Demoed0.00 sqft 0.00 sqft 0.00 sqft 0.00 sqftExisting to Remain0.00 sqft 0.00 sqft 0.00 sqft 0.00 sqftNew (non-exempt)1128.63 sqft 0.00 sqft 0.00 sqft 0.00 sqftNew (exempt)0.00 sqft 0.00 sqft 0.00 sqftTotal New1128.63 sqft 0.00 sqft 0.00 sqft 0.00 sqftTotal on site1128.63 sqft 0.00 sqft 0.00 sqft 0.00 sqftTotal Snowmelt on siteBoiler Efficiency95.0%100%95.0%95.0%Mitigation Payment -$ -$ Total Payment for Mitigation:40,393.07$ B.ON-SITE RENEWABLE CREDITSSupplemental SystemREMP CreditUse PV WorksheetPhotovoltaic System -$ Use Thermal WorksheetHot Water Panels -$ 2015 IECC RESIDENTIAL RENEWABLE ENERGY MITIGATION PROGRAMCity of Aspen Version 11.3 UpdAted deCember 13, 2017533 West Hallam Aspen CO 81611 Wlewis@BillPoss.comWilliam Lewis 1128.63 sqft 605 East Main Street G007(970) 925-4755 $40,393.07 Yes (enter sqft below on the exempt row)No Please fill out the contact infoportion of this form. If the siteplan/REMP plan are revised perdiscussions with HPC andbuilding regarding the light wellguards, please be sure toupdate the square footages onthis sheet accordingly. You need an approved fabricator'ssignature for the shop weldsshown in the structural plans. Please resubmit the agreement. You may resubmit responseswithout this if you have yet todecide on your welder/steelfabricator but building will not beable to sign off on your permit untilthis agreement has been fullyexecuted. Wind LoadingBasic Wind Speed Vult= 115 MPH Vasd= 90 MPHExposure Category BGCpi0.18Wind Base Shear - Ultimate 21.9 K Wind Design Pressure Components & Cladding - Ultimate 50ft2East/WestNorth/South Local Jurisdiction: City of AspenBuilding Code: 2015 International Building Code -34.4 PSFInterior Roof Zone (Zone 1)-47.0 PSFRoof End Zone (Zone 2) STRUCTURAL DESIGN CRITERIARisk Category: II 20ft2-42.3 PSF-54.1 PSF 100ft2-28.4 PSF-41.7 PSF (Note 1) 19.8 K SURANCEactor is responsible for quality assurance, including ship and materials furnished by subcontractors and suppliers. n or testing by the Owner does not relieve the Contractor of his ility to perform the work in accordance with the Contract ts. nship: The Contractor is responsible and shall bear the cost of g work which does not conform to the specified requirements. eficient work by means acceptable to the Architect. The cost of k incurred by the Architect to approve corrective work shall be the Contractor.NTROLer's Testing Agency shall perform testing and special inspections by the structural documents, building code and the local The Testing Agency shall comply with ASTM E329 and upon on of work, the Testing Agency shall furnish a certificate of ce, signed by the professional engineer overseeing special ABBRE AB anchor ADDNL addition AFF above f ALT alternat ARCH architec BLDG buildingBM beamBOT, B/, BOx bottom BRG bearingBS both si BTWN betweenCIP cast-in CJ constru CJP complet CLR clearCMU concret COL column Our wind speeddesign criteria is 89MPH, please revise. Are you still planning on using an approved fabricatorfor shop welds as this response implies, or will you beusing custom structural steel as an inspectedfabricator for both shop and field welds. Pleaseclarify, I can accept either but any shop welds done bythe inspected fabricator must still be inspected byyour special inspector. THE METERS ARE SHOWN ON THE EAST ELEVATION, BUT NOW ARE NOTED. DETAILS HAVE BEEN REVISED: ZIP PANELS ARE NO LONGER BEING USED; WRB WILL BE APPLIED TO THE INSULATED SHEATHING PANELS. WHEN INSTALLED LESS THAN 6" ABOVE GRADE THE SHEATHING WILL BE PRESSURE TREATED. STRUCTURAL DRAWINGS HAVE BEEN NOTED ACCORDINGLY. WE WILL BE USING STRUCTURAL STEEL AS AN INSPECTED FABRICATOR FOR BOTH SHOP & FIELD WELDS. UPDATED SPECIAL INSPECTION & TESTING AGREEMENT IS INCLUDED IN THE RESPONSE DOCUMENTS. 02/28/2020 Is the solar disconnect and meter shown on that elevation for future installation of solar? There is no mention of solar in the plans or on the REMP worksheet, please clarify. Please resend the revised structural plans you referenced, I could not find them in this resubmittal. Subject: PlanCheck Page: [5] C2 Site Plan Author: justinh Color: File Name: Civil - Comment Response Drawings.pdf Civil plans are calling out snowmelt in areas that are not shown as being snowmelted in the REMP plan, revise one or the other so that they match. You are also still showing patio around window wells that was removed on the architectural site plan to avoid needing guards. Revise all plans to match. Civil - Comment Response Drawings.pdf (2) Subject: PlanCheck Page: [5] C2 Site Plan Author: justinh Color: File Name: Civil - Comment Response Drawings.pdf REMP plan shows this as being a snowmelted area, and it is not above the basement roof. Details on C7 do not show snowmelt. If this is pervious snowmelt provide a detail showing the proposed hole pattern and insulation thickness for the pervious snowmelt that still obtains a weighted average of R10. Subject: PlanCheck Page: 1 Author: justinh Color: File Name: Mechanical - 2015 IECC REMP Calcuations - Response.pdf Sign the REMP worksheet. Mechanical - 2015 IECC REMP Calcuations - Response.pdf (1) Subject: PlanCheck Page: M-111A LOWER LEVEL HVAC FLOOR PLAN Author: justinh Color: File Name: Mechanical - Comment Response Drawing.pdf Where is your outdoor air intake located? I'm realizing I was not looking at the correct item previously and I just want to clarify the issue so that I can verify it meets the requirements for intake location. Mechanical - Comment Response Drawing.pdf (1) Civil plans are calling out snowmelt in areas that arenot shown as being snowmelted in the REMP plan,revise one or the other so that they match. You are also still showing patio around window wellsthat was removed on the architectural site plan toavoid needing guards. Revise all plans to match. REMP plan shows this as being a snowmelted area, andit is not above the basement roof. Details on C7 do notshow snowmelt. If this is pervious snowmelt provide adetail showing the proposed hole pattern and insulationthickness for the pervious snowmelt that still obtains aweighted average of R10. Hydro Snowmelt Electric Snowmelt Pool SpaExisting0.00 sqft 0.00 sqft 0.00 sqft 0.00 sqftTo be Demoed 0.00 sqft 0.00 sqft 0.00 sqft 0.00 sqftExisting to Remain 0.00 sqft 0.00 sqft 0.00 sqft 0.00 sqftNew (non-exempt)1056.06 sqft 0.00 sqft 0.00 sqft 0.00 sqftNew (exempt)36.00 sqft 0.00 sqft 0.00 sqftTotal New 1092.06 sqft 0.00 sqft 0.00 sqft 0.00 sqftTotal on site 1092.06 sqft 0.00 sqft 0.00 sqft 0.00 sqftTotal Snowmelt on siteBoiler Efficiency 95.0%100%95.0% 95.0%Mitigation Payment -$ -$ Total Payment for Mitigation:37,795.83$ B.ON-SITE RENEWABLE CREDITS Supplemental System REMP CreditUse PV WorksheetPhotovoltaic System -$ Use Thermal WorksheetHot Water Panels -$ Use GSHP CertGround Source Heat Pump -$ Other Approved System -$ Total Mitigation Credits:-$ Onsite Renewable Offsets: How many KiloWatts of PV (solar electric) would I need? 5.51or How many square feet of SHW (solar hot water) would I need? 168.24 R-REMP Payment:37,795.83$ Amount Previously Paid on This Permit:37,795.83$ Refund (includes minus $750): -$ C. PREPARED BY:Date: 9/9/2019 Print Name: Signature: Phone & EMail: REVIEWED:Date: 970 748 8520 TOTAL R-REMP PAYMENT: 1092.06 sqft Bryan Urban $37,795.83 Sign the REMPworksheet. 89 Where is your outdoor air intake located? I'm realizing I was not looking at the correct item previously and I just want to clarify the issue so that I can verify it meets the requirements for intake location. CIVIL PLAN & THE RREMP PLAN REVISED TO REFLECT THE SAME AREAS TO BE SNOWMELTED. FOR THE EGRESS WELLS THE RESOLUTION WAS TO BE ABLE HAVE A WALKABLE SURFACE ONLY ON ONE SIDE, THE EGRESS SIDE & HAVE A METAL PLAQUE STATING "THIS EMERGENCY ESCAPE GRATE MUST REMAIN CLEAR AND UNOBSTRUCTED AT ALL TIMES" AS NOTED ON THE ACHITECTURAL SITE PLAN. REMP WORKSHEET SIGNED & ATTACHED TO RESPONSE. ALSO,THE REMP CALC'S HAVE BEEN REVISED DUE TO THE ELIMINATION OF A ROW OF PATIO PAVERS. THE OUTDOOR INTAKE IS LOCATED ON THE FIRST FLOOR HVAC PLAN AND ADDITIONAL NOTING HAS BEEN PROVIDED. THE DETAIL ON C7 HAS BEEN REVISED TO ONLY ADDRESS THE EAST SIDE OF THE RESIDENCE. 02/28/2020 This intake location is less than 10' from the property line and does not comply with IMC 401.4, revise to comply.