Loading...
HomeMy WebLinkAboutInspection.533 W Hallam St.0285.2018 (21).ARBKDOUBLE POCKET LARGESINGLE SWING - TWO PANEL SINGLE POCKET - TWO PANEL T.O. SHTHG @ REF. PLANS ID302 11 ID302 12 ID302 11 ID302 12 ID302 2 7 1 / 2 " 10 " 3"DOUBLE POCKET SMALL ID302 11 ID302 12 10 " 3" 7 1 / 2 " 7 1 / 2 " 3" 10 " 3" 10 " 7 1 / 2 " SINGLE SWING - ONE PANEL ID302 2 3" 10 " 7 1 / 2 " SINGLE POCKET - ONE PANEL ID302 11 ID302 12 7 1 / 2 " 3" 10 " EXTERIOR 2' - 6" INTERIOR 2' - 6" DOOR DIMENSIONS GENERAL NOTES 1)REFERENCE FLOOR PLANS FOR DOOR HANDING. NOTIFY ARCHITECT OF ANY DISCREPENCIES. 2)REFERENCE ELEVATIONS FOR WINDOW HANDING AND OPERATION. NOTIFY ARCHITECT OF ANY DISCREPENCIES. 3)ALL WINDOWS AND DOORS TO HAVE "LOW E" INSULATED GLAZING U.N.O. THEY SHOULD ALSO BE RATED FOR HIGH ALTITUDES, PER MANUFACTORER'S SPECIFICATION. 4)PROVIDE WEATHERSTRIPPING AND ALUMINUM THRESHOLDS FOR ALL EXTERIOR DOORS, U.N.O. 5)VERIFY WINDOW AND DOOR HARDWARE FINISHES WITH OWNER PRIOR TO ORDERING. 6)TEMPERED GLASS MUST BE PROVIDED IN ALL HAZARDOUS AREAS PER SECTION R308 2015 IRC. 7)ALL WINDOWS TO COMPY WITH 2015 IECC CHAPTER 4, CLIMATE ZONE 7 & 8, FENESTRATION U- FACTOR 0.28. WINDOW MANUFACTORER TO PROVIDE DOCUMENTATION FOR THE WINDOW PACKAGE DEMONSTRATING A WEIGHTED AVERAGE OF U-VALUE 0.28 AND NFRC STICKERS ON WINDOW AND DOORS FOR APPROVAL BY THE CITY OF ASPEN BUILDING DEPARTMENT. 8)INDICATES SAFETY GLASS. 9)INDICATES EGRESS. 10)R.O.'S ARE 1/2" BEYOND OVERALL FRAME DIMENSIONS. 11)FIELD VERIFY ALL R.O. DIMENSIONS BEFORE ORDERING. 12)PROVIDE SCREENS FOR OPERABLE WINDOWS. COORDINATE WITH ARCHITECT. 13)SEE REFLECTED CEILING PLANS FOR REFERENCED SHADE POCKET DETAILS & DESCRIPTION. T E T.O. SHEATHING @ MAIN LEVEL A911 7 A911 8 A911 9 1 1 / 2 " 8' - 1 1 / 2 " 3' - 4" 1 1 / 2 " 8' - 1 1 / 2 " 3' - 4" A911 4 A911 5 A911 6 103 A 107 A A910 1 A910 2 A910 3 A910 5 110 A TT TTT DTL NEED DTL NEED DTL NEED 111 A NEW ENTRY DOOR NOTE: 1. LOWER PROFILE AND PROPORTIONS TO MATCH 113B. SINGLE WINDOW TO FOLLOW HISTORIC STYLING OF 113 B. 2. ENTRY DOOR TO BE PAINTED TO MATCH MAIN LEVEL POWDER BATHROOM DOOR (105A) 7' - 2 " 3' - 4" DTL NEED DTL NEED DTL NEED113 A HISTORIC REPLICA TO MIRROR 113 B DRAWN NOT DRAWN NOT DRAWN NOT113 B HISTORIC 6' - 8 " 2' - 8"2' - 8" 6' - 8 " A910 8 A910 10 A910 9 106 A 101 A A911 2 A911 3 A911 1 TT T 3' - 4" 8' - 1 1 / 2 " 1 1 / 2 " T.O. SHTHG @ MAIN LEVEL A910 11 109 A A910 7 A910 6 A910 1 A910 4 T T T T 103 B 2" 8' - 1 " TBD TBD TBD TBD TBD TBD 1 1 / 2 " 9' - 1 1 / 2 " 11' - 4 1/2" 3' - 0" 8' - 5 1/4" 3' - 0"EQ.EQ. 1 1 / 2 " 9' - 1 1 / 2 " 1 1 / 2 " 9' - 1 1 / 2 " 7' - 5" 2 1 / 4 " 45° 5 1/2" 1/ 4 " 1/ 2 " 1" 2 1 / 4 " 1" 1/ 2 " 1/ 4 " 2 1 / 4 " 45° 3 1/2" 1/ 4 " 1/ 2 " 1" INTERIOR DOOR NOTES 1)RATED DOOR. 2)PAINT TO MATCH TYPICAL WALL COLOR. 3)PAINT TO MATCH SW BLACK. 4)PROVIDE FULL LENGTH GLASS MIRROR AND BACKING TO FIT DOOR STYLE. Consultant ARCHITECTURE PLANNING+ ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T, A S P E N, C O L O R A D O 8 1 6 1 1 SHEET TITLE BILL POSS AND ASSOCIATES, ARCHITECTURE AND PLANNING, P.C. THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS THE PROPERTY OF BILL POSS AND ASSOCIATES, ARCHITECTURE AND PLANNING, P.C. NO PART OF THIS INFORMATION MAY BE USED WITHOUT THE PRIOR WRITTEN PERMISSION OF BILL POSS AND ASSOCIATES, ARCHITECTURE AND PLANNING, P.C. BILL POSS AND ASSOCIATES, ARCHITECTURE AND PLANNING, P.C. SHALL RETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING COPYRIGHT THERETO. c 2019 PROJECT NO: Issue: 4/ 7 / 2 0 2 0 1 2 : 4 9 : 1 7 P M DUNCAN RESIDENCE 533 W HALLAM ST ASPEN, CO 81611 A901 INTERIOR & EXTERIOR DOOR SCHEDULE W/ DOOR TYPE ELEVATIONS 21708.00 INTERIOR DOOR: TYPES EXTERIOR DOOR SCHEDULE DOOR MARK DOOR TYPE FRAME MANUFACTURER U-VALUE NOTESWIDTH HEIGHT 101 A SINGLE SWING 3' - 4" 8' - 1 1/2" DYNAMIC .27 TEMPERED GLASS 103 A SINGLE SWING 3' - 4" 8' - 1 1/2" DYNAMIC .27 TEMPERED GLASS 103 B GARAGE NORTHWEST DOOR 106 A LIFT & SLIDE DYNAMIC .26 TEMPERED GLASS 107 A SINGLE SWING 3' - 4" 8' - 1 1/2" DYNAMIC .27 TEMPERED GLASS 109 A 4 PANEL SLIDING 11' - 4 1/2" 9' - 1 1/2" DYNAMIC .26 TEMPERED GLASS 110 A 3 PANEL SLIDING 8' - 5 1/4" 9' - 1 1/2" DYNAMIC .26 TEMPERED GLASS 111 A SINGLE SWING 3' - 4" 7' - 2".27 NEW ENTRY DOOR. LOWER PROFILE AND PROPORTIONS TO MATCH 113 B. SINGLE WINDOW TO FOLLOW HISTORIC STYLING OF 113 B. ENTRY DOOR TO BE PAINTED TO MATCH MAIN LEVEL POWDER BATHROOM DOOR (105A) 113 A HISTORIC SINGLE SWING 2' - 8" 6' - 8"HISTORIC REPLICA TO MIRROR 113 B 113 B HISTORIC SINGLE SWING 2' - 8" 6' - 8"EXISTING HISTORIC DOOR EXTERIOR DOORS 7' -5"9' -1 1/2" 1 02.04.2019 PRELIMINARY PRICING 2 05.28.2019 PRICING SET 3 10.09.2019 COA COMMENTS RESPONSE 10.15.2019 PRICING SET 01.08.2020 CHECK SET 12.06.2019 WINDOW AND DOOR SCHEDULE PACKAGE 02.24.2020 PERMIT COMMENTS ROUND 2 18' -0"8' -1" INTERIOR DOOR SCHEDULE DOOR MARK DOOR TYPE LEAF THRESHOLD INTERIOR DOOR NOTESWIDTH HEIGHT 002 A SINGLE SWING - TWO PANEL 2' - 6" 8' - 0" 7 / ID302 2 004 A SINGLE SWING - TWO PANEL 3' - 0" 7' - 0" 4 / ID302 2 005 A SINGLE SWING - TWO PANEL 2' - 10" 8' - 0" 7 / ID302 2 005 B SINGLE POCKET - TWO PANEL 3' - 0" 8' - 0" 4 / ID302 2 010 A SINGLE SWING - TWO PANEL 2' - 10" 8' - 0" 4 / ID302 2 011 A SINGLE POCKET - TWO PANEL 2' - 8" 8' - 0" 2 012 A SINGLE POCKET - ONE PANEL 2' - 6" 8' - 0" 2,4 013 A SINGLE SWING - TWO PANEL 2' - 8" 8' - 0" 1 / ID302 2 020 A SINGLE SWING - TWO PANEL 2' - 10" 8' - 0" 4 / ID302 2 021 A SINGLE SWING - TWO PANEL 2' - 8" 8' - 0" 2 022 A SINGLE SWING - ONE PANEL 2' - 4" 8' - 0" 2,4 023 A SINGLE POCKET - TWO PANEL 2' - 8" 8' - 0" 1 / ID302 2 026 A SINGLE POCKET - TWO PANEL 3' - 0" 8' - 0" 7 / ID302 2 030 A SINGLE SWING - TWO PANEL 2' - 10" 8' - 0" 7 / ID302 2 031 A SINGLE POCKET - TWO PANEL 2' - 8" 8' - 0" 2 032 A SINGLE POCKET - ONE PANEL 2' - 6" 8' - 0" 2,4 033 A SINGLE SWING - TWO PANEL 2' - 8" 8' - 0" 1 / ID302 2 040 A SINGLE SWING - TWO PANEL 3' - 0" 8' - 0" 7 / ID302 2 041 A SINGLE SWING - ONE PANEL 2' - 8" 8' - 0" 2,4 042 A SINGLE SWING - TWO PANEL 2' - 8" 8' - 0" 1 / ID302 2 101 B SINGLE SWING - TWO PANEL 3' - 0" 8' - 0" 1 / ID302 1,2 102 A DOUBLE POCKET LARGE 4' - 0" 8' - 0" 2 105 A SINGLE SWING - TWO PANEL 2' - 6" 8' - 0" 7 / ID302 3 108 A SINGLE POCKET - TWO PANEL 2' - 10" 7' - 6" 2 114 A DOUBLE POCKET LARGE 5' - 0" 8' - 0" 7 / ID302 2 202 A SINGLE SWING - TWO PANEL 3' - 0" 8' - 0" 1 / ID302 2 203 A SINGLE SWING - TWO PANEL 3' - 0" 8' - 0" 4 / ID302 2 203 B DOUBLE POCKET SMALL 3' - 0" 8' - 0" 2 204 A DOUBLE POCKET SMALL 3' - 2" 8' - 0" 2 205 A DOUBLE POCKET SMALL 3' - 2" 8' - 0" 2 207 A DOUBLE POCKET SMALL 3' - 0" 8' - 0" 1 / ID302 2 SCALE 3" = 1'-0" INTERIOR DOOR PANEL STYLE SCALE 3" = 1'-0" INTERIOR DOOR PANEL STYLE SCALE 3" = 1'-0" INTERIOR DOOR PANEL STYLE 04/20/2020 04/21/2020 justinh REVIEWED FOR COMPLIANCE 04/21/2020 sarahy BY HPC GENERAL NOTES 1)REFERENCE FLOOR PLANS FOR DOOR HANDING. NOTIFY ARCHITECT OF ANY DISCREPENCIES. 2)REFERENCE ELEVATIONS FOR WINDOW HANDING AND OPERATION. NOTIFY ARCHITECT OF ANY DISCREPENCIES. 3)ALL WINDOWS AND DOORS TO HAVE "LOW E" INSULATED GLAZING U.N.O. THEY SHOULD ALSO BE RATED FOR HIGH ALTITUDES, PER MANUFACTORER'S SPECIFICATION. 4)PROVIDE WEATHERSTRIPPING AND ALUMINUM THRESHOLDS FOR ALL EXTERIOR DOORS, U.N.O. 5)VERIFY WINDOW AND DOOR HARDWARE FINISHES WITH OWNER PRIOR TO ORDERING. 6)TEMPERED GLASS MUST BE PROVIDED IN ALL HAZARDOUS AREAS PER SECTION R308 2015 IRC. 7)ALL WINDOWS TO COMPY WITH 2015 IECC CHAPTER 4, CLIMATE ZONE 7 & 8, FENESTRATION U- FACTOR 0.28. WINDOW MANUFACTORER TO PROVIDE DOCUMENTATION FOR THE WINDOW PACKAGE DEMONSTRATING A WEIGHTED AVERAGE OF U-VALUE 0.28 AND NFRC STICKERS ON WINDOW AND DOORS FOR APPROVAL BY THE CITY OF ASPEN BUILDING DEPARTMENT. 8)INDICATES SAFETY GLASS. 9)INDICATES EGRESS. 10)R.O.'S ARE 1/2" BEYOND OVERALL FRAME DIMENSIONS. 11)FIELD VERIFY ALL R.O. DIMENSIONS BEFORE ORDERING. 12)PROVIDE SCREENS FOR OPERABLE WINDOWS. COORDINATE WITH ARCHITECT. 13)SEE REFLECTED CEILING PLANS FOR REFERENCED SHADE POCKET DETAILS & DESCRIPTION. T E 5' - 9 " 2' - 6 " 5' - 9 " 2' - 6 " 5' - 9 " 2' - 6 " 5' - 9 " 2' - 6 " 5' - 9 " 2' - 6 " 5' - 9 " 2' - 6 " 2' - 6"2' - 6"2' - 6"2' - 6"2' - 6"2' - 6" 2' - 0 " 6' - 3 " 2' - 0 " 6' - 3 " 3' - 0"2' - 0" 3' - 8 3/4"3' - 8 3/4" 7' - 5 1/2" 3' - 1 1 3 / 4 " 4' - 1 1 / 4 " 1' - 7" 5' - 9 1 / 2 " 1' - 7 1 / 2 " 1' - 11 1/4"2' - 2 3/4" 5' - 1 0 " 1' - 7 1 / 2 " A 01 A 02 A 03 A 04 A 05 A 06 T.O. CONCRETE @ LOWER LEVEL A907 7 E E E E A907 2 A907 3 A906 2 A906 3 A904 8 A904 6 A905 11 A905 12 A905 10 A904 4 A906 1 A907 1 B 02 B 03 B 04 B 05 T.O. SHTHG @ MAIN LEVEL B 06 A907 8 A907 9 T.O. SHTHG @ MAIN LEVEL B 10 B 11 HISTORIC REPLICA TO MATCH B19 & B20 HISTORIC TT 8' - 3 " 8' - 3 " 8' - 3 " 8' - 3 " 8' - 3 " 8' - 3 " 8' - 3 " 8' - 3 " 3" 9' - 0 " 8' - 1 " 7' - 5 1 / 2 " 7' - 5 " A907 10 A907 11 A907 12 A907 10 A907 11 A907 12 A907 10 A907 11 A907 12 A907 10 A907 11 A907 12 A907 7 A907 8 A907 9 A905 8 A905 9 A905 7 A904 2 A904 3 A904 1 A904 2 A904 3 A904 1 A904 8 SIM B 01 T.O. SHTHG @ MAIN LEVEL A907 5 A907 6 A907 4 6' - 7" 3' - 3 1/2"3' - 3 1/2" 8' - 3 " 6' - 3 " 2' - 0 " 5' - 9 1 / 2 " 1' - 7 1 / 2 " 5' - 9 1 / 2 " 1' - 7 1 / 2 " 1' - 11 1/4"2' - 3 3/8" B 07 B 08 HISTORIC HISTORIC A904 2 A904 3 A904 1 7' - 5 " 7' - 5 " A904 2 A904 3 A904 1 5' - 9 1 / 2 " 1' - 7 1 / 2 " 2' - 3 3/8" B 09 HISTORIC 7' - 5 " A904 2 A904 3 A904 1 B 12 2' - 9" 3' - 1 1 " 3' - 0 " 1' - 11 1/4" 5' - 9 1 / 2 " 1' - 5 " 7' - 2 1 / 2 " 6' - 1 1 " B 13 HISTORIC HISTORIC STAINED GLASS RELOCATED EXISTING EXISTING EXISTING T.O. SHTHG @ MAIN LEVEL 5' - 9 1 / 2 " 1' - 5 " 7' - 2 1 / 2 " 5' - 9 1 / 2 " 1' - 5 " 7' - 2 1 / 2 " 5' - 9 1 / 2 " 1' - 5 " 7' - 2 1 / 2 " 2' - 3 1/4"2' - 3 1/4"1' - 11 1/4" EXISTING EXISTING EXISTING B 14 B 15 B 16 HISTORIC HISTORIC HISTORIC EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING 9' - 3 " 3' - 1 1 3 / 4 " 4' - 1 1 / 4 " 8' - 1 " Consultant ARCHITECTURE PLANNING+ ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T, A S P E N, C O L O R A D O 8 1 6 1 1 SHEET TITLE BILL POSS AND ASSOCIATES, ARCHITECTURE AND PLANNING, P.C. THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS THE PROPERTY OF BILL POSS AND ASSOCIATES, ARCHITECTURE AND PLANNING, P.C. NO PART OF THIS INFORMATION MAY BE USED WITHOUT THE PRIOR WRITTEN PERMISSION OF BILL POSS AND ASSOCIATES, ARCHITECTURE AND PLANNING, P.C. BILL POSS AND ASSOCIATES, ARCHITECTURE AND PLANNING, P.C. SHALL RETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING COPYRIGHT THERETO. c 2019 PROJECT NO: Issue: 4/ 7 / 2 0 2 0 1 2 : 4 9 : 1 7 P M DUNCAN RESIDENCE 533 W HALLAM ST ASPEN, CO 81611 A902 WINDOW SCHEDULE W/ WINDOW ELEVATIONS 21708.00 WINDOW SCHEDULE WINDOW MARK FRAME SIZE OPERATION MANUFACT URER U-VALUE NOTESWIDTH HEIGHT A 01 2' - 6" 5' - 9" CASEMENT DYNAMIC .3 EGRESS A 02 2' - 6" 5' - 9" FIXED DYNAMIC .25 A 03 2' - 6" 5' - 9" CASEMENT DYNAMIC .3 EGRESS A 04 2' - 6" 5' - 9" CASEMENT DYNAMIC .3 EGRESS A 05 2' - 6" 5' - 9" CASEMENT DYNAMIC .3 EGRESS A 06 2' - 6" 5' - 9" FIXED DYNAMIC .25 B 01 6' - 6" 2' - 0" FIXED-FIXED DYNAMIC .25 B 02 3' - 0" 2' - 0" FIXED DYNAMIC ,25 B 03 2' - 0" 2' - 0" AWNING DYNAMIC .3 B 04 7' - 5 1/2" 9' - 0" FIXED-FIXED DYNAMIC .25 TEMPERED GLASS B 05 1' - 8" 3' - 11 1/4".3 B 06 1' - 8" 3' - 11 1/4".3 B 07 1' - 11 1/4" 5' - 9 1/2" DOUBLE HUNG EXISTING HISTORIC DOUBLE HUNG B 08 2' - 3 3/8" 5' - 9 1/2" DOUBLE HUNG EXISTING HISTORIC DOUBLE HUNG B 09 2' - 3 3/8" 5' - 9 1/2" DOUBLE HUNG EXISTING HISTORIC DOUBLE HUNG B 10 1' - 11 1/4" 5' - 9 1/2" DOUBLE HUNG EXISTING HISTORIC DOUBLE HUNG B 11 2' - 2 3/4" 5' - 10" DOUBLE HUNG PARRETT HISTORIC REPLICA TO MATCH B 18 & B 19 B 12 2' - 9" 3' - 11" FIXED HISTORIC STAINED GLASS, RELOCATED B 13 1' - 11 1/4" 5' - 9 1/2" DOUBLE HUNG EXISTING HISTORIC DOUBLE HUNG B 14 2' - 3 1/4" 5' - 9 1/2" DOUBLE HUNG EXISTING HISTORIC DOUBLE HUNG B 15 2' - 3 1/4" 5' - 9 1/2" DOUBLE HUNG EXISTING HISTORIC DOUBLE HUNG B 16 1' - 11 1/4" 5' - 9 1/2" DOUBLE HUNG EXISTING HISTORIC DOUBLE HUNG B 17 1' - 10" 1' - 4" FIXED EXISTING HISTORIC STAINED GLASS B 18 2' - 2 3/4" 5' - 10" DOUBLE HUNG PARRETT EXISTING HISTORIC DOUBLE HUNG B 19 2' - 2 3/4" 5' - 10" DOUBLE HUNG PARRETT EXISTING HISTORIC DOUBLE HUNG B 20 2' - 2 3/4" 5' - 10" DOUBLE HUNG PARRETT EXISTING HISTORIC DOUBLE HUNG B 21 2' - 2 3/4" 5' - 10" DOUBLE HUNG PARRETT HISTORIC REPLICA TO MATCH B 18 & B 19 B 22 2' - 2 3/4" 5' - 10" DOUBLE HUNG PARRETT HISTORIC REPLICA TO MATCH B 18 & B 19 B 23 1' - 10" 1' - 4" FIXED HISTORIC REPLICA TO MATCH B 17 B 24 5' - 0" 5' - 6" DOUBLE HUNG-DOUBLE HUNG DYNAMIC .31 B 25 2' - 0" 3' - 0" AWNING DYNAMIC .3 MOTORIZED AWNING C 01 4' - 8" 5' - 6" DOUBLE HUNG-DOUBLE HUNG DYNAMIC .31 TEMPERED GLASS C 02 2' - 0" 3' - 0" AWNING DYNAMIC .3 MOTORIZED AWNING C 03 2' - 6" 5' - 2" DOUBLE HUNG DYNAMIC .31 C 04 2' - 6" 5' - 2" DOUBLE HUNG DYNAMIC .31 C 05 8' - 10" 5' - 2" CASEMENT-FIXED-CASEMENT DYNAMIC .3 C 06 6' - 3 1/2" 5' - 6" DOUBLE HUNG-DOUBLE HUNG DYNAMIC .31 EGRESS C 07 2' - 0" 3' - 0" AWNING DYNAMIC .3 C 08 7' - 5 1/2" 8' - 9" FIXED-FIXED DYNAMIC .25 TEMPERED GLASS C 09 2' - 6" 4' - 8" DOUBLE HUNG DYNAMIC .31 C 10 2' - 6" 5' - 2" DOUBLE HUNG DYNAMIC .31 1 02.04.2019 PRELIMINARY PRICING 2 05.28.2019 PRICING SET 3 10.09.2019 COA COMMENTS RESPONSE 01.08.2020 CHECK SET 12.06.2019 WINDOW AND DOOR SCHEDULE PACKAGE 02.24.2020 PERMIT COMMENTS ROUND 2 04/20/2020 04/21/2020 justinh