Loading...
HomeMy WebLinkAboutFile Documents.614 North St.0248.2017 (115).ARBKEXISTING CONIFEROUS TREE TO BE REMOVED EXISTING DECIDUOUS TREE TO BE REMOVED EXISTING CONIFEROUS TREE TO REMAIN EXISTING DECIDUOUS TREE TO REMAIN NEW DECIDUOUS TREE NEW CONIFEROUS TREE SITE PLAN LEGEND ASPHALT/PAVEMENT DRIVEWAY EXTERIOR DECK IMPERVIOUS PAVERS EXISTING DRIVEWAY TO BE REMOVED GRAVELEXISTING BUSHES TO BE REMOVED CABLE ELECTRIC LINE TELEPHONE LINE SEWER LINE PERVIOUS PAVERS TOPOGRAPHY LEGEND EXISTING 1' CONTOUR PROPOSED 1' CONTOUR PROPOSED 5' CONTOUR EXISTING 5' CONTOUR 10'-0" 5'- 0 " 5'- 0 " 5'-0" 10'-0" T.O. PAVER99'-6" T.O. PLY100'-0" 40 3 22 22 78 9 1 7891 7890 7890 789 2 EXISTING DRIVEWAY TO REMAIN WE S T N O R T H S T R E E T EXISTING PORCH TO BEREMOVED 789 1 FRON T Y A R D SETB A C K SID E Y A R D SE T B A C K AL L E Y A/C SID E Y A R D SE T B A C K REAR Y A R D SETBAC K 7890 E G LEGAL ADDRESS: 614 W NORTH ST ZONE DISTRICT : R-6 LOT SIZE: 4,050 SQFT PROJECT 100'-0" = 7891'-9" 624 W NORTH STREET LOT 13 610 W NORTH STREET LOT 16 PROPERTY LIN E SETBACK LINE PR O P E R T Y L I N E SE T B A C K L I N E PROPERTY LINE SETBACK LINE PR O P E R T Y L I N E 5' R E A R S E T B A C K L I N E 10 ' R E A R S E T B A C K L I N E REAR Y A R D SETBAC K EXISTING FOOTPRINT TO REMAIN COVERED PORCH RESIDENCE IS ACCESSED FROM PRIVATE ALLEY A/C A/C 35' 35' 19' 21' 14' 6'6'6' 6'9'9' 12" C M P EXISTING LIGHT WELLEXISTING LIGHT WELL EXISTING LIGHT WELL EXISTING PATIO TO BE REMOVED EXISTING FENCE EXISTING FENCE MAILBOX WOOD RETAINING WALL EXISTING SIDEWALK TO BE REMOVED EXISTING TRENCH DRAIN WOOD RETAINING WALLWOOD RETAINING WALL ELECTRICTRANSFORMER 1.) EXISTING FRAMING & SHEATHING TO REMAIN AT AREAS NOT SHOWN AS DEMOLISHED. TYPICAL. 2.) ALL DIMENSIONS TO EXISTING WALLS TO BE VERIFIED IN FIELD. TYPICAL. 3.) EXISTING RIDGE HEIGHTS TO REMAIN. 4.) ALL EXTERIOR MATERIALS TO REMAIN AND TO BE RE-FINISHED UNLESS NOTED OTHERWISE. 5.) ALL EXISTING WINDOWS AND EXTERIOR DOORS TO BE REPLACED. VERIFY IN FILED PRIOR TO ALL SHOP DRAWING APPROVALS. 6.) VERIFY ALL EXISTING & PROPOSED SPOT ELEVATIONS IN FIELD. PROJECT 100'-0" IS IN RELATION TO EXISTING TOP OF PLYWOOD ON THE MAIN LEVEL. GENERAL PLAN NOTES N04'8'12'SCALE: 3/16" = 1'-0" EXISTING SITE PLAN STEVEN WILSON 402127 STA T E OF COLO R A D O L I C E NSED AR C H ITECT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t BUILDING NO GREATER THAN 50FT IN DEPTH, UNLESS ACCESSORY & SEPARATE FROM MAIN PER RDS B.1.d.(1) VEHICULAR ACCESS VIA ALLEY OR PRIVATE STREET PER RDS C.1.c STREET FACING ENTRY DOOR NOT SET BACK MORE THAN 10 FT FROM PRINCIPAL FACADE PER RDS D.1.d.(1) ENTRY DOOR NO TALLER THAN 8FT PER RDS D.2.c ENTRY PORCH NOT MORE THAN ONE-STORY IN HEIGHT PER RDS D.3.c GROUP OF WINDOWS ON FRONT FACADE PER RDS E.1.d.(2) NO STREET-FACING WINDOWS MORE THAN ONE-STORY PER RDS E.2.c EXTERIOR MATERIALS CONSISTENT ON ALL SIDES & TRUE TO CHARACTERISTICS PER RDS E.5.c R-6 ZONE DISTRICT HEIGHT LIMIT 25' 60% + OF FRONT FACADE WITHIN REQ'D DISTANCE OF MINIMUM SETBACK PER RDS B.3.c LIGHTWELL PER RDS E.4.c & IRC R310.1 FRONT PORCH PER PER 26.575.020.D.5 VERTICAL CIRCULATION NOT COUNTED ON UPPER MOST FLOOR PER 26.575.020.D.2.a PATIO AT OR WITHIN 6" OF FINISHED GRADE PER 26.575.020.D.6 ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.j PROPOSED DRIVEWAY WITHIN 30" OF FINISHED GRADE PER 26.575.020.E.5.q TOP MOST PORTION OF ROOF PER 26.575.020.F.2 CHIMNEY PROTECTION <10' FROM HEIGHT OFBUILDING CONNECTION PER 26.575.020.F.4.a SAFETY GLAZING RADON VENT PIPE EXISTING HORIZONTAL WOOD SIDING TO BE REPAINTED VERTICAL METAL SIDING TBD STANDING SEAM ROOF SYNTHETIC SHINGLE EMERGENCY ESCAPE AND RESCUE DOORS PER IRC R310.3 DWELLING-GARAGE FIRE SEPARATIONPER IRC R302.6 BARS, GRILLS, COVERS, SCREENS OVER EMERGENCY ESCAPES AND RESCUE OPENING PER RDS 310.4 LINE OF EXTERIOR WALL BELOW DRIVEWAY TO REMAIN EXTERIOR DECK MATERIAL TBD HANDRAIL PER IRC 311.7.8 & 311.7.8.1 MIN HEIGHT 34" AC UNITS GUTTER SNOW STOPS / SNOW FENCE PANEL TO BE NON-LOCKING FLIP-UP GRATE & REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION DOWNSPOUT PROPOSED GRADE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE LIGHTWELL MINIMUM OPENING AREA PER IRC R310.2.1SNOWMELT PER IRC 310 LIFE & SAFETY DWELLING-GARAGE OPENING ANDPENETRATION PROTECTION PER IRC R302.5 GAS + ELECTRIC METERS ROOF OVERHANG GLASS GUARD SAFETY GLAZED PER IRC 308.4 &SUPPORT POINT LOAD PER IRC 301.5 DRYER FLUE VENT; TYP LINE OF FOUNDATION BELOW FALL PROTECTION PROVIDED PER R612.2 1/4" PER 1' SLOPE GAS LANTERNS BEVOLO CONTEMPORARY SERIES ASPHAULT SHINGLES TO BE REPLACED BRICK TO MATCH PAVER TBD LINE OF PROPOSED GRADE 2" CURB TYP. HOSE BIB LADDER AND STEPS PER IRC R310.2.3.1 1/2 POINT FROM EAVE TO RIDGE 1/3 POINT FROM EAVE TO RIDGE DRAWING ISSUANCE INDEX ID 01 02 03 NAME SCHEMATIC APPROVAL DD RDS REVIEW ISSUED DATE 10/2/17, 11:34 AM 10/2/17, 11:35 AM 10/2/17, 12:02 PM COPYRIGHT 10/2/17 KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION Z-003X EXISTING SITE PLAN 10/2/17 RJL/JM/IS 1712.00 Aspen CO 81611 614 W NORTH ST Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Basalt: 104 Midland Ave, #202 Basalt, CO 81612 forumphi.com p: 970.279.4157 f: 866.770.5585 273512112006 7/10/17, 5:00 PM 9/1/17, 10:00 AM 2/27/2018 EXISTING CONIFEROUS TREE TO BE REMOVED EXISTING DECIDUOUS TREE TO BE REMOVED EXISTING CONIFEROUS TREE TO REMAIN EXISTING DECIDUOUS TREE TO REMAIN NEW DECIDUOUS TREE NEW CONIFEROUS TREE SITE PLAN LEGEND ASPHALT/PAVEMENT DRIVEWAY EXTERIOR DECK IMPERVIOUS PAVERS EXISTING DRIVEWAY TO BE REMOVED GRAVELEXISTING BUSHES TO BE REMOVED CABLE ELECTRIC LINE TELEPHONE LINE SEWER LINE PERVIOUS PAVERS 10'-0" 5'- 0 " 5'- 0 " 5'-0" 35 ' - 8 1/ 4 " 7'-97/8" 10'-0" T.O. PAVER99'-6" T.O. PAVER99'-10" T.O. PLY100'-0" 54.7731° 20.3799° 29.1112° 75.7966° 40 27 28 9 29 27 28 9 29 27 28 9 29 4 3 13 13 57 53 53 78 9 1 7891 7890 7890 789 2 EXISTING DRIVEWAY TO REMAIN WE S T N O R T H S T R E E T 789 1 FRON T Y A R D SETB A C K SID E Y A R D SE T B A C K AL L E Y SID E Y A R D SE T B A C K REAR Y A R D SETBAC K 7890 LEGAL ADDRESS: 614 W NORTH ST ZONE DISTRICT : R-6 LOT SIZE: 4,050 SQFT PROJECT 100'-0" = 7891'-9" 624 W NORTH STREET LOT 13 610 W NORTH STREET LOT 16 28'-13/4" 18' - 1 1 1/4" PROPERTY LIN E SETBACK LINE PR O P E R T Y L I N E SE T B A C K L I N E PROPERTY LINE SETBACK LINE PR O P E R T Y L I N E 5' R E A R S E T B A C K L I N E 10 ' R E A R S E T B A C K L I N E REAR Y A R D SETBAC K PATIO <6" OF GRADE RESIDENCE IS ACCESSED FROM PRIVATE ALLEY A/C A/C TRASH35' 35' 19' 21' 14' 6'6'6' 6'9'9' 12" C M P MAILBOX ELECTRICTRANSFORMER TOPOGRAPHY LEGEND EXISTING 1' CONTOUR PROPOSED 1' CONTOUR PROPOSED 5' CONTOUR EXISTING 5' CONTOUR 1.) EXISTING FRAMING & SHEATHING TO REMAIN AT AREAS NOT SHOWN AS DEMOLISHED. TYPICAL. 2.) ALL DIMENSIONS TO EXISTING WALLS TO BE VERIFIED IN FIELD. TYPICAL. 3.) EXISTING RIDGE HEIGHTS TO REMAIN. 4.) ALL EXTERIOR MATERIALS TO REMAIN AND TO BE RE-FINISHED UNLESS NOTED OTHERWISE. 5.) ALL EXISTING WINDOWS AND EXTERIOR DOORS TO BE REPLACED. VERIFY IN FILED PRIOR TO ALL SHOP DRAWING APPROVALS. 6.) VERIFY ALL EXISTING & PROPOSED SPOT ELEVATIONS IN FIELD. PROJECT 100'-0" IS IN RELATION TO EXISTING TOP OF PLYWOOD ON THE MAIN LEVEL. GENERAL PLAN NOTES N04'8'12'SCALE: 3/16" = 1'-0" PROPOSED SITE PLAN STEVEN WILSON 402127 STA T E OF COLO R A D O L I C E NSED AR C H ITECT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t BUILDING NO GREATER THAN 50FT IN DEPTH, UNLESS ACCESSORY & SEPARATE FROM MAIN PER RDS B.1.d.(1) VEHICULAR ACCESS VIA ALLEY OR PRIVATE STREET PER RDS C.1.c STREET FACING ENTRY DOOR NOT SET BACK MORE THAN 10 FT FROM PRINCIPAL FACADE PER RDS D.1.d.(1) ENTRY DOOR NO TALLER THAN 8FT PER RDS D.2.c ENTRY PORCH NOT MORE THAN ONE-STORY IN HEIGHT PER RDS D.3.c GROUP OF WINDOWS ON FRONT FACADE PER RDS E.1.d.(2) NO STREET-FACING WINDOWS MORE THAN ONE-STORY PER RDS E.2.c EXTERIOR MATERIALS CONSISTENT ON ALL SIDES & TRUE TO CHARACTERISTICS PER RDS E.5.c R-6 ZONE DISTRICT HEIGHT LIMIT 25' 60% + OF FRONT FACADE WITHIN REQ'D DISTANCE OF MINIMUM SETBACK PER RDS B.3.c LIGHTWELL PER RDS E.4.c & IRC R310.1 FRONT PORCH PER PER 26.575.020.D.5 VERTICAL CIRCULATION NOT COUNTED ON UPPER MOST FLOOR PER 26.575.020.D.2.a PATIO AT OR WITHIN 6" OF FINISHED GRADE PER 26.575.020.D.6 ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.j PROPOSED DRIVEWAY WITHIN 30" OF FINISHED GRADE PER 26.575.020.E.5.q TOP MOST PORTION OF ROOF PER 26.575.020.F.2 CHIMNEY PROTECTION <10' FROM HEIGHT OFBUILDING CONNECTION PER 26.575.020.F.4.a SAFETY GLAZING RADON VENT PIPE EXISTING HORIZONTAL WOOD SIDING TO BE REPAINTED VERTICAL METAL SIDING TBD STANDING SEAM ROOF SYNTHETIC SHINGLE EMERGENCY ESCAPE AND RESCUE DOORS PER IRC R310.3 DWELLING-GARAGE FIRE SEPARATIONPER IRC R302.6 BARS, GRILLS, COVERS, SCREENS OVER EMERGENCY ESCAPES AND RESCUE OPENING PER RDS 310.4 LINE OF EXTERIOR WALL BELOW DRIVEWAY TO REMAIN EXTERIOR DECK MATERIAL TBD HANDRAIL PER IRC 311.7.8 & 311.7.8.1 MIN HEIGHT 34" AC UNITS GUTTER SNOW STOPS / SNOW FENCE PANEL TO BE NON-LOCKING FLIP-UP GRATE & REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION DOWNSPOUT PROPOSED GRADE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE LIGHTWELL MINIMUM OPENING AREA PER IRC R310.2.1SNOWMELT PER IRC 310 LIFE & SAFETY DWELLING-GARAGE OPENING ANDPENETRATION PROTECTION PER IRC R302.5 GAS + ELECTRIC METERS ROOF OVERHANG GLASS GUARD SAFETY GLAZED PER IRC 308.4 &SUPPORT POINT LOAD PER IRC 301.5 DRYER FLUE VENT; TYP LINE OF FOUNDATION BELOW FALL PROTECTION PROVIDED PER R612.2 1/4" PER 1' SLOPE GAS LANTERNS BEVOLO CONTEMPORARY SERIES ASPHAULT SHINGLES TO BE REPLACED BRICK TO MATCH PAVER TBD LINE OF PROPOSED GRADE 2" CURB TYP. HOSE BIB LADDER AND STEPS PER IRC R310.2.3.1 1/2 POINT FROM EAVE TO RIDGE 1/3 POINT FROM EAVE TO RIDGE DRAWING ISSUANCE INDEX ID 01 02 03 NAME SCHEMATIC APPROVAL DD RDS REVIEW ISSUED DATE 10/2/17, 11:34 AM 10/2/17, 11:35 AM 10/2/17, 12:02 PM COPYRIGHT 10/2/17 KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION Z-003 PROPOSED SITE PLAN 10/2/17 RJL/JM/IS 1712.00 Aspen CO 81611 614 W NORTH ST Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Basalt: 104 Midland Ave, #202 Basalt, CO 81612 forumphi.com p: 970.279.4157 f: 866.770.5585 273512112006 7/10/17, 5:00 PM 9/1/17, 10:00 AM 2/27/2018 2 2 3 3 4 4 5 5 6 6 E E D D C C A A 63'-11/2" 4'-2"10'-1"18'-10"26'-7"3'-51/2" 36 ' - 8 1/ 4 " 3' - 3 " 10 ' - 6 1/ 4 " 5' - 7 " 8' - 0 1/ 2 " 6' - 4 1/ 2 " 2' - 1 1 " 63'-11/2" 4'-2"1'-93/4"15'-2"4'-83/4"14'-8"6'-61/2"12'-7"3'-51/2" 36 ' - 8 1/ 4 " 2' - 1 1 " T.O. CONC.91'-0"T.O. CONC.91'-0" PROPERTY LIN E SETBACK LINE PR O P E R T Y L I N E SE T B A C K L I N E PROPERTY LIN E SETBACK LINE PR O P E R T Y L I N E 5' R E A R S E T B A C K L I N E 10 ' R E A R S E T B A C K L I N E 16 ' - 3 5/ 8 " 11 ' - 1 0 5/8 " 5' - 6 7/8 " MEDIA 002 MECH 006 LAUNDRY 004 BEDROOM 005 BEDROOM 001 BATH 003 CRAWL 007 CRAWL 008 B B 4 Z-203X 1 Z-201X 2 Z-202X 3 Z-201X 1.) EXISTING FRAMING & SHEATHING TO REMAIN AT AREAS NOT SHOWN AS DEMOLISHED. TYPICAL. 2.) ALL DIMENSIONS TO EXISTING WALLS TO BE VERIFIED IN FIELD. TYPICAL. 3.) EXISTING RIDGE HEIGHTS TO REMAIN. 4.) ALL EXTERIOR MATERIALS TO REMAIN AND TO BE RE-FINISHED UNLESS NOTED OTHERWISE. 5.) ALL EXISTING WINDOWS AND EXTERIOR DOORS TO BE REPLACED. VERIFY IN FILED PRIOR TO ALL SHOP DRAWING APPROVALS. 6.) VERIFY ALL EXISTING & PROPOSED SPOT ELEVATIONS IN FIELD. PROJECT 100'-0" IS IN RELATION TO EXISTING TOP OF PLYWOOD ON THE MAIN LEVEL. GENERAL PLAN NOTES EXISTING TO REMAIN TO BE DEMOLISHED NEW WALL WALL LEGEND N02'4'8'SCALE: 1/4" = 1'-0" EXISTING LOWER LEVEL STEVEN WILSON 402127 STA T E OF COLO R A D O L I C E NSED AR C H ITECT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t BUILDING NO GREATER THAN 50FT IN DEPTH, UNLESS ACCESSORY & SEPARATE FROM MAIN PER RDS B.1.d.(1) VEHICULAR ACCESS VIA ALLEY OR PRIVATE STREET PER RDS C.1.c STREET FACING ENTRY DOOR NOT SET BACK MORE THAN 10 FT FROM PRINCIPAL FACADE PER RDS D.1.d.(1) ENTRY DOOR NO TALLER THAN 8FT PER RDS D.2.c ENTRY PORCH NOT MORE THAN ONE-STORY IN HEIGHT PER RDS D.3.c GROUP OF WINDOWS ON FRONT FACADE PER RDS E.1.d.(2) NO STREET-FACING WINDOWS MORE THAN ONE-STORY PER RDS E.2.c EXTERIOR MATERIALS CONSISTENT ON ALL SIDES & TRUE TO CHARACTERISTICS PER RDS E.5.c R-6 ZONE DISTRICT HEIGHT LIMIT 25' 60% + OF FRONT FACADE WITHIN REQ'D DISTANCE OF MINIMUM SETBACK PER RDS B.3.c LIGHTWELL PER RDS E.4.c & IRC R310.1 FRONT PORCH PER PER 26.575.020.D.5 VERTICAL CIRCULATION NOT COUNTED ON UPPER MOST FLOOR PER 26.575.020.D.2.a PATIO AT OR WITHIN 6" OF FINISHED GRADE PER 26.575.020.D.6 ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.j PROPOSED DRIVEWAY WITHIN 30" OF FINISHED GRADE PER 26.575.020.E.5.q TOP MOST PORTION OF ROOF PER 26.575.020.F.2 CHIMNEY PROTECTION <10' FROM HEIGHT OFBUILDING CONNECTION PER 26.575.020.F.4.a SAFETY GLAZING RADON VENT PIPE EXISTING HORIZONTAL WOOD SIDING TO BE REPAINTED VERTICAL METAL SIDING TBD STANDING SEAM ROOF SYNTHETIC SHINGLE EMERGENCY ESCAPE AND RESCUE DOORS PER IRC R310.3 DWELLING-GARAGE FIRE SEPARATIONPER IRC R302.6 BARS, GRILLS, COVERS, SCREENS OVER EMERGENCY ESCAPES AND RESCUE OPENING PER RDS 310.4 LINE OF EXTERIOR WALL BELOW DRIVEWAY TO REMAIN EXTERIOR DECK MATERIAL TBD HANDRAIL PER IRC 311.7.8 & 311.7.8.1 MIN HEIGHT 34" AC UNITS GUTTER SNOW STOPS / SNOW FENCE PANEL TO BE NON-LOCKING FLIP-UP GRATE & REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION DOWNSPOUT PROPOSED GRADE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE LIGHTWELL MINIMUM OPENING AREA PER IRC R310.2.1SNOWMELT PER IRC 310 LIFE & SAFETY DWELLING-GARAGE OPENING ANDPENETRATION PROTECTION PER IRC R302.5 GAS + ELECTRIC METERS ROOF OVERHANG GLASS GUARD SAFETY GLAZED PER IRC 308.4 &SUPPORT POINT LOAD PER IRC 301.5 DRYER FLUE VENT; TYP LINE OF FOUNDATION BELOW FALL PROTECTION PROVIDED PER R612.2 1/4" PER 1' SLOPE GAS LANTERNS BEVOLO CONTEMPORARY SERIES ASPHAULT SHINGLES TO BE REPLACED BRICK TO MATCH PAVER TBD LINE OF PROPOSED GRADE 2" CURB TYP. HOSE BIB LADDER AND STEPS PER IRC R310.2.3.1 1/2 POINT FROM EAVE TO RIDGE 1/3 POINT FROM EAVE TO RIDGE DRAWING ISSUANCE INDEX ID 01 02 03 NAME SCHEMATIC APPROVAL DD RDS REVIEW ISSUED DATE 10/2/17, 11:34 AM 10/2/17, 11:35 AM 10/2/17, 12:02 PM COPYRIGHT 10/2/17 KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION Z-101X EXISTING LOWER LEVEL 10/2/17 RJL/JM/IS 1712.00 Aspen CO 81611 614 W NORTH ST Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Basalt: 104 Midland Ave, #202 Basalt, CO 81612 forumphi.com p: 970.279.4157 f: 866.770.5585 273512112006 7/10/17, 5:00 PM 9/1/17, 10:00 AM 2/27/2018 F RG DW 2 2 3 3 4 4 5 5 6 6 E E D D C C A A B B 59'-8" 4'-2"10'-1"18'-10"4'-1"22'-6" 35 ' - 5 1/ 4 " 2' - 0 " 10 ' - 6 1/ 4 " 20 ' - 0 " 2' - 4 1/2 " 61/ 2 " 59'-8" 4'-2"16'-71/4"5'-53/4"20'-10"12'-7" 33 ' - 5 1/ 4 " 16 ' - 1 0 " 10'-0 " 5'- 0 " T.O. PLY100'-0" T.O. CONC.99'-11 1/2" 4 Z-203X 1 Z-201X 2 Z-202X 3 Z-201X EXISTING DRIVEWAY PROPERTY LIN E SETBACK LINE PR O P E R T Y L I N E SE T B A C K L I N E PROPERTY LIN E SETBACK LINE PR O P E R T Y L I N E 5' R E A R S E T B A C K L I N E 10 ' R E A R S E T B A C K L I N E 2'- 4 5/ 8 " 11 ' - 1 0 5/8 " 2' - 3 7/8 " DINING 104 LIVING ROOM 108 PWDR 103 ENTRY 102 FAMILY ROOM 107 KITCHEN 105 GARAGE 106 ENTRY PORCH 101 1.) EXISTING FRAMING & SHEATHING TO REMAIN AT AREAS NOT SHOWN AS DEMOLISHED. TYPICAL. 2.) ALL DIMENSIONS TO EXISTING WALLS TO BE VERIFIED IN FIELD. TYPICAL. 3.) EXISTING RIDGE HEIGHTS TO REMAIN. 4.) ALL EXTERIOR MATERIALS TO REMAIN AND TO BE RE-FINISHED UNLESS NOTED OTHERWISE. 5.) ALL EXISTING WINDOWS AND EXTERIOR DOORS TO BE REPLACED. VERIFY IN FILED PRIOR TO ALL SHOP DRAWING APPROVALS. 6.) VERIFY ALL EXISTING & PROPOSED SPOT ELEVATIONS IN FIELD. PROJECT 100'-0" IS IN RELATION TO EXISTING TOP OF PLYWOOD ON THE MAIN LEVEL. GENERAL PLAN NOTES EXISTING TO REMAIN TO BE DEMOLISHED NEW WALL WALL LEGEND N02'4'8'SCALE: 1/4" = 1'-0" EXISTING MAIN LEVEL STEVEN WILSON 402127 STA T E OF COLO R A D O L I C E NSED AR C H ITECT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t BUILDING NO GREATER THAN 50FT IN DEPTH, UNLESS ACCESSORY & SEPARATE FROM MAIN PER RDS B.1.d.(1) VEHICULAR ACCESS VIA ALLEY OR PRIVATE STREET PER RDS C.1.c STREET FACING ENTRY DOOR NOT SET BACK MORE THAN 10 FT FROM PRINCIPAL FACADE PER RDS D.1.d.(1) ENTRY DOOR NO TALLER THAN 8FT PER RDS D.2.c ENTRY PORCH NOT MORE THAN ONE-STORY IN HEIGHT PER RDS D.3.c GROUP OF WINDOWS ON FRONT FACADE PER RDS E.1.d.(2) NO STREET-FACING WINDOWS MORE THAN ONE-STORY PER RDS E.2.c EXTERIOR MATERIALS CONSISTENT ON ALL SIDES & TRUE TO CHARACTERISTICS PER RDS E.5.c R-6 ZONE DISTRICT HEIGHT LIMIT 25' 60% + OF FRONT FACADE WITHIN REQ'D DISTANCE OF MINIMUM SETBACK PER RDS B.3.c LIGHTWELL PER RDS E.4.c & IRC R310.1 FRONT PORCH PER PER 26.575.020.D.5 VERTICAL CIRCULATION NOT COUNTED ON UPPER MOST FLOOR PER 26.575.020.D.2.a PATIO AT OR WITHIN 6" OF FINISHED GRADE PER 26.575.020.D.6 ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.j PROPOSED DRIVEWAY WITHIN 30" OF FINISHED GRADE PER 26.575.020.E.5.q TOP MOST PORTION OF ROOF PER 26.575.020.F.2 CHIMNEY PROTECTION <10' FROM HEIGHT OFBUILDING CONNECTION PER 26.575.020.F.4.a SAFETY GLAZING RADON VENT PIPE EXISTING HORIZONTAL WOOD SIDING TO BE REPAINTED VERTICAL METAL SIDING TBD STANDING SEAM ROOF SYNTHETIC SHINGLE EMERGENCY ESCAPE AND RESCUE DOORS PER IRC R310.3 DWELLING-GARAGE FIRE SEPARATIONPER IRC R302.6 BARS, GRILLS, COVERS, SCREENS OVER EMERGENCY ESCAPES AND RESCUE OPENING PER RDS 310.4 LINE OF EXTERIOR WALL BELOW DRIVEWAY TO REMAIN EXTERIOR DECK MATERIAL TBD HANDRAIL PER IRC 311.7.8 & 311.7.8.1 MIN HEIGHT 34" AC UNITS GUTTER SNOW STOPS / SNOW FENCE PANEL TO BE NON-LOCKING FLIP-UP GRATE & REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION DOWNSPOUT PROPOSED GRADE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE LIGHTWELL MINIMUM OPENING AREA PER IRC R310.2.1SNOWMELT PER IRC 310 LIFE & SAFETY DWELLING-GARAGE OPENING ANDPENETRATION PROTECTION PER IRC R302.5 GAS + ELECTRIC METERS ROOF OVERHANG GLASS GUARD SAFETY GLAZED PER IRC 308.4 &SUPPORT POINT LOAD PER IRC 301.5 DRYER FLUE VENT; TYP LINE OF FOUNDATION BELOW FALL PROTECTION PROVIDED PER R612.2 1/4" PER 1' SLOPE GAS LANTERNS BEVOLO CONTEMPORARY SERIES ASPHAULT SHINGLES TO BE REPLACED BRICK TO MATCH PAVER TBD LINE OF PROPOSED GRADE 2" CURB TYP. HOSE BIB LADDER AND STEPS PER IRC R310.2.3.1 1/2 POINT FROM EAVE TO RIDGE 1/3 POINT FROM EAVE TO RIDGE DRAWING ISSUANCE INDEX ID 01 02 03 NAME SCHEMATIC APPROVAL DD RDS REVIEW ISSUED DATE 10/2/17, 11:34 AM 10/2/17, 11:35 AM 10/2/17, 12:02 PM COPYRIGHT 10/2/17 KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION Z-102X EXISTING MAIN LEVEL 10/2/17 RJL/JM/IS 1712.00 Aspen CO 81611 614 W NORTH ST Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Basalt: 104 Midland Ave, #202 Basalt, CO 81612 forumphi.com p: 970.279.4157 f: 866.770.5585 273512112006 7/10/17, 5:00 PM 9/1/17, 10:00 AM 2/27/2018 2 2 3 3 4 4 5 5 6 6 E E D D C C A A B B 4 Z-203X 1 Z-201X 2 Z-202X 3 Z-201X 52'-41/2" 33 ' - 5 1/ 4 " 52'-41/2" 33 ' - 5 1/ 4 " 4'-2"10'-1"18'-10"4'-1"15'-21/2" 10 ' - 6 1/ 4 " 20 ' - 0 " 1' - 1 0 1/2 " 1' - 0 1/ 2 " 4'-2"42'-11"5'-31/2" 16 ' - 1 0 " T.O. PLY108'-6" T.O. PLY109'-6"T.O. PLY109'-6" T.O. PLY109'-6" T.O. PLY108'-6" PROPERTY LIN E SETBACK LINE PR O P E R T Y L I N E SE T B A C K L I N E PROPERTY LIN E SETBACK LINE PR O P E R T Y L I N E 5' R E A R S E T B A C K L I N E 10 ' R E A R S E T B A C K L I N E 2'- 4 5/ 8 " 11 ' - 1 0 5/8 " 2' - 3 7/8 " MASTER BEDROOM 202 BATH 206 MASTER CLO 201 OFFICE 204 MASTER BATH 205 BEDROOM 207 BEDROOM 208 ROOF DECK 203 1.) EXISTING FRAMING & SHEATHING TO REMAIN AT AREAS NOT SHOWN AS DEMOLISHED. TYPICAL. 2.) ALL DIMENSIONS TO EXISTING WALLS TO BE VERIFIED IN FIELD. TYPICAL. 3.) EXISTING RIDGE HEIGHTS TO REMAIN. 4.) ALL EXTERIOR MATERIALS TO REMAIN AND TO BE RE-FINISHED UNLESS NOTED OTHERWISE. 5.) ALL EXISTING WINDOWS AND EXTERIOR DOORS TO BE REPLACED. VERIFY IN FILED PRIOR TO ALL SHOP DRAWING APPROVALS. 6.) VERIFY ALL EXISTING & PROPOSED SPOT ELEVATIONS IN FIELD. PROJECT 100'-0" IS IN RELATION TO EXISTING TOP OF PLYWOOD ON THE MAIN LEVEL. GENERAL PLAN NOTES EXISTING TO REMAIN TO BE DEMOLISHED NEW WALL WALL LEGEND N02'4'8'SCALE: 1/4" = 1'-0" EXISTING UPPER LEVEL STEVEN WILSON 402127 STA T E OF COLO R A D O L I C E NSED AR C H ITECT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t BUILDING NO GREATER THAN 50FT IN DEPTH, UNLESS ACCESSORY & SEPARATE FROM MAIN PER RDS B.1.d.(1) VEHICULAR ACCESS VIA ALLEY OR PRIVATE STREET PER RDS C.1.c STREET FACING ENTRY DOOR NOT SET BACK MORE THAN 10 FT FROM PRINCIPAL FACADE PER RDS D.1.d.(1) ENTRY DOOR NO TALLER THAN 8FT PER RDS D.2.c ENTRY PORCH NOT MORE THAN ONE-STORY IN HEIGHT PER RDS D.3.c GROUP OF WINDOWS ON FRONT FACADE PER RDS E.1.d.(2) NO STREET-FACING WINDOWS MORE THAN ONE-STORY PER RDS E.2.c EXTERIOR MATERIALS CONSISTENT ON ALL SIDES & TRUE TO CHARACTERISTICS PER RDS E.5.c R-6 ZONE DISTRICT HEIGHT LIMIT 25' 60% + OF FRONT FACADE WITHIN REQ'D DISTANCE OF MINIMUM SETBACK PER RDS B.3.c LIGHTWELL PER RDS E.4.c & IRC R310.1 FRONT PORCH PER PER 26.575.020.D.5 VERTICAL CIRCULATION NOT COUNTED ON UPPER MOST FLOOR PER 26.575.020.D.2.a PATIO AT OR WITHIN 6" OF FINISHED GRADE PER 26.575.020.D.6 ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.j PROPOSED DRIVEWAY WITHIN 30" OF FINISHED GRADE PER 26.575.020.E.5.q TOP MOST PORTION OF ROOF PER 26.575.020.F.2 CHIMNEY PROTECTION <10' FROM HEIGHT OFBUILDING CONNECTION PER 26.575.020.F.4.a SAFETY GLAZING RADON VENT PIPE EXISTING HORIZONTAL WOOD SIDING TO BE REPAINTED VERTICAL METAL SIDING TBD STANDING SEAM ROOF SYNTHETIC SHINGLE EMERGENCY ESCAPE AND RESCUE DOORS PER IRC R310.3 DWELLING-GARAGE FIRE SEPARATIONPER IRC R302.6 BARS, GRILLS, COVERS, SCREENS OVER EMERGENCY ESCAPES AND RESCUE OPENING PER RDS 310.4 LINE OF EXTERIOR WALL BELOW DRIVEWAY TO REMAIN EXTERIOR DECK MATERIAL TBD HANDRAIL PER IRC 311.7.8 & 311.7.8.1 MIN HEIGHT 34" AC UNITS GUTTER SNOW STOPS / SNOW FENCE PANEL TO BE NON-LOCKING FLIP-UP GRATE & REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION DOWNSPOUT PROPOSED GRADE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE LIGHTWELL MINIMUM OPENING AREA PER IRC R310.2.1SNOWMELT PER IRC 310 LIFE & SAFETY DWELLING-GARAGE OPENING ANDPENETRATION PROTECTION PER IRC R302.5 GAS + ELECTRIC METERS ROOF OVERHANG GLASS GUARD SAFETY GLAZED PER IRC 308.4 &SUPPORT POINT LOAD PER IRC 301.5 DRYER FLUE VENT; TYP LINE OF FOUNDATION BELOW FALL PROTECTION PROVIDED PER R612.2 1/4" PER 1' SLOPE GAS LANTERNS BEVOLO CONTEMPORARY SERIES ASPHAULT SHINGLES TO BE REPLACED BRICK TO MATCH PAVER TBD LINE OF PROPOSED GRADE 2" CURB TYP. HOSE BIB LADDER AND STEPS PER IRC R310.2.3.1 1/2 POINT FROM EAVE TO RIDGE 1/3 POINT FROM EAVE TO RIDGE DRAWING ISSUANCE INDEX ID 01 02 03 NAME SCHEMATIC APPROVAL DD RDS REVIEW ISSUED DATE 10/2/17, 11:34 AM 10/2/17, 11:35 AM 10/2/17, 12:02 PM COPYRIGHT 10/2/17 KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION Z-103X EXISTING UPPER LEVEL 10/2/17 RJL/JM/IS 1712.00 Aspen CO 81611 614 W NORTH ST Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Basalt: 104 Midland Ave, #202 Basalt, CO 81612 forumphi.com p: 970.279.4157 f: 866.770.5585 273512112006 7/10/17, 5:00 PM 9/1/17, 10:00 AM 2/27/2018 2 2 3 3 4 4 5 5 6 6 E E D D C C A A B B 4 Z-203X 1 Z-201X 2 Z-202X 3 Z-201X 35 ' - 8 1/ 4 " 18 ' - 1 0 1/ 4 " 16 ' - 1 0 " 57'-9" 45'-2"5'-31/2"7'-31/2" 35 ' - 8 1/ 4 " 10 ' - 6 1/4 " 22 ' - 3 " 2' - 1 1 " 57'-9" 10'-7"20'-7"19'-31/2"7'-31/2" ROOF DECK BELOW PROPERTY LIN E SETBACK LINE PR O P E R T Y L I N E SE T B A C K L I N E PROPERTY LIN E SETBACK LINE PR O P E R T Y L I N E 5' R E A R S E T B A C K L I N E 10 ' R E A R S E T B A C K L I N E 12:12 12:12 12:12 12:12 12:12 6:12 6:12 6:12 4:12 12:12 12:12 12:12 12:12 12:12 12:12 12:12 12:12 EXISTING CHIMNEY TO BE REMOVED 2323 23 23 ALL EXISTING SHINGLES TO BE REPLACED. EXISTING FRAMING; SHEATHING TO REMAIN. VERIFY ALL EXISTING ROOF HEIGHTS IN FIELD. 12:12 12:12 12:12 6:12 6:12 ALL EXISTING SHINGLES TO BE REPLACED. EXISTING FRAMING; SHEATHING TO REMAIN. VERIFY ALL EXISTING ROOF HEIGHTS IN FIELD. 12:12 1.) EXISTING FRAMING & SHEATHING TO REMAIN AT AREAS NOT SHOWN AS DEMOLISHED. TYPICAL. 2.) ALL DIMENSIONS TO EXISTING WALLS TO BE VERIFIED IN FIELD. TYPICAL. 3.) EXISTING RIDGE HEIGHTS TO REMAIN. 4.) ALL EXTERIOR MATERIALS TO REMAIN AND TO BE RE-FINISHED UNLESS NOTED OTHERWISE. 5.) ALL EXISTING WINDOWS AND EXTERIOR DOORS TO BE REPLACED. VERIFY IN FILED PRIOR TO ALL SHOP DRAWING APPROVALS. 6.) VERIFY ALL EXISTING & PROPOSED SPOT ELEVATIONS IN FIELD. PROJECT 100'-0" IS IN RELATION TO EXISTING TOP OF PLYWOOD ON THE MAIN LEVEL. GENERAL PLAN NOTES EXISTING TO REMAIN TO BE DEMOLISHED NEW ROOF ROOF DEMO LEGEND N02'4'8'SCALE: 1/4" = 1'-0" EXISTING ROOF PLAN STEVEN WILSON 402127 STA T E OF COLO R A D O L I C E NSED AR C H ITECT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t BUILDING NO GREATER THAN 50FT IN DEPTH, UNLESS ACCESSORY & SEPARATE FROM MAIN PER RDS B.1.d.(1) VEHICULAR ACCESS VIA ALLEY OR PRIVATE STREET PER RDS C.1.c STREET FACING ENTRY DOOR NOT SET BACK MORE THAN 10 FT FROM PRINCIPAL FACADE PER RDS D.1.d.(1) ENTRY DOOR NO TALLER THAN 8FT PER RDS D.2.c ENTRY PORCH NOT MORE THAN ONE-STORY IN HEIGHT PER RDS D.3.c GROUP OF WINDOWS ON FRONT FACADE PER RDS E.1.d.(2) NO STREET-FACING WINDOWS MORE THAN ONE-STORY PER RDS E.2.c EXTERIOR MATERIALS CONSISTENT ON ALL SIDES & TRUE TO CHARACTERISTICS PER RDS E.5.c R-6 ZONE DISTRICT HEIGHT LIMIT 25' 60% + OF FRONT FACADE WITHIN REQ'D DISTANCE OF MINIMUM SETBACK PER RDS B.3.c LIGHTWELL PER RDS E.4.c & IRC R310.1 FRONT PORCH PER PER 26.575.020.D.5 VERTICAL CIRCULATION NOT COUNTED ON UPPER MOST FLOOR PER 26.575.020.D.2.a PATIO AT OR WITHIN 6" OF FINISHED GRADE PER 26.575.020.D.6 ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.j PROPOSED DRIVEWAY WITHIN 30" OF FINISHED GRADE PER 26.575.020.E.5.q TOP MOST PORTION OF ROOF PER 26.575.020.F.2 CHIMNEY PROTECTION <10' FROM HEIGHT OFBUILDING CONNECTION PER 26.575.020.F.4.a SAFETY GLAZING RADON VENT PIPE EXISTING HORIZONTAL WOOD SIDING TO BE REPAINTED VERTICAL METAL SIDING TBD STANDING SEAM ROOF SYNTHETIC SHINGLE EMERGENCY ESCAPE AND RESCUE DOORS PER IRC R310.3 DWELLING-GARAGE FIRE SEPARATIONPER IRC R302.6 BARS, GRILLS, COVERS, SCREENS OVER EMERGENCY ESCAPES AND RESCUE OPENING PER RDS 310.4 LINE OF EXTERIOR WALL BELOW DRIVEWAY TO REMAIN EXTERIOR DECK MATERIAL TBD HANDRAIL PER IRC 311.7.8 & 311.7.8.1 MIN HEIGHT 34" AC UNITS GUTTER SNOW STOPS / SNOW FENCE PANEL TO BE NON-LOCKING FLIP-UP GRATE & REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION DOWNSPOUT PROPOSED GRADE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE LIGHTWELL MINIMUM OPENING AREA PER IRC R310.2.1SNOWMELT PER IRC 310 LIFE & SAFETY DWELLING-GARAGE OPENING ANDPENETRATION PROTECTION PER IRC R302.5 GAS + ELECTRIC METERS ROOF OVERHANG GLASS GUARD SAFETY GLAZED PER IRC 308.4 &SUPPORT POINT LOAD PER IRC 301.5 DRYER FLUE VENT; TYP LINE OF FOUNDATION BELOW FALL PROTECTION PROVIDED PER R612.2 1/4" PER 1' SLOPE GAS LANTERNS BEVOLO CONTEMPORARY SERIES ASPHAULT SHINGLES TO BE REPLACED BRICK TO MATCH PAVER TBD LINE OF PROPOSED GRADE 2" CURB TYP. HOSE BIB LADDER AND STEPS PER IRC R310.2.3.1 1/2 POINT FROM EAVE TO RIDGE 1/3 POINT FROM EAVE TO RIDGE DRAWING ISSUANCE INDEX ID 01 02 03 NAME SCHEMATIC APPROVAL DD RDS REVIEW ISSUED DATE 10/2/17, 11:34 AM 10/2/17, 11:35 AM 10/2/17, 12:02 PM COPYRIGHT 10/2/17 KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION Z-104X EXISTING ROOF PLAN 10/2/17 RJL/JM/IS 1712.00 Aspen CO 81611 614 W NORTH ST Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Basalt: 104 Midland Ave, #202 Basalt, CO 81612 forumphi.com p: 970.279.4157 f: 866.770.5585 273512112006 7/10/17, 5:00 PM 9/1/17, 10:00 AM 2/27/2018 E D C B A 9' - 0 " 8'- 6 " 1' - 0 " 12 ' - 7 9/ 3 2 " 2' - 7 9/1 6 " EXISTING GRADE EXISTING MAIN LEVEL T.O. PLY 100'-0" = 7891'-9" EXISTING UPPER LEVEL T.O. PLY 109'-6" T.O. EXISTING RIDGE 124'-8 1/2" T.O. EXISTING RIDGE 127'-0" EXISTING UPPER LEVEL STEP T.O. PLY 108'-6" EXISTING LOWER LEVEL T.O. CONC. 91'-0" SE T B A C K L I N E PR O P E R T Y L I N E SE T B A C K L I N E 2'- 3 3/8 " T.O. EXISTING RIDGE 122'-1 9/32" A B C D E 9' - 0 " 8'- 6 " 1' - 0 " 12 ' - 7 9/ 3 2 " 2' - 7 9/1 6 " EXISTING GRADE EXISTING MAIN LEVEL T.O. PLY 100'-0" = 7891'-9" EXISTING UPPER LEVEL T.O. PLY 109'-6" T.O. EXISTING RIDGE 124'-8 1/2" T.O. EXISTING RIDGE 127'-0" EXISTING UPPER LEVEL STEP T.O. PLY 108'-6" EXISTING LOWER LEVEL T.O. CONC. 91'-0" PR O P E R T Y L I N E SE T B A C K L I N E 2'- 3 3/8 " T.O. EXISTING RIDGE 122'-1 9/32" 1.) EXISTING FRAMING & SHEATHING TO REMAIN AT AREAS NOT SHOWN AS DEMOLISHED. TYPICAL. 2.) ALL DIMENSIONS TO EXISTING WALLS TO BE VERIFIED IN FIELD. TYPICAL. 3.) EXISTING RIDGE HEIGHTS TO REMAIN. 4.) ALL EXTERIOR MATERIALS TO REMAIN AND TO BE RE-FINISHED UNLESS NOTED OTHERWISE. 5.) ALL EXISTING WINDOWS AND EXTERIOR DOORS TO BE REPLACED. VERIFY IN FILED PRIOR TO ALL SHOP DRAWING APPROVALS. 6.) VERIFY ALL EXISTING & PROPOSED SPOT ELEVATIONS IN FIELD. PROJECT 100'-0" IS IN RELATION TO EXISTING TOP OF PLYWOOD ON THE MAIN LEVEL. GENERAL PLAN NOTES EXISTING TO REMAIN TO BE DEMOLISHED NEW WALL WALL LEGEND 0 2'4'8'SCALE: 1/4" = 1'-0"1 EXISTING SOUTH ELEVATION 0 2'4'8'SCALE: 1/4" = 1'-0"3 EXISTING NORTH ELEVATION STEVEN WILSON 402127 STA T E OF COLO R A D O L I C E NSED AR C H ITECT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t BUILDING NO GREATER THAN 50FT IN DEPTH, UNLESS ACCESSORY & SEPARATE FROM MAIN PER RDS B.1.d.(1) VEHICULAR ACCESS VIA ALLEY OR PRIVATE STREET PER RDS C.1.c STREET FACING ENTRY DOOR NOT SET BACK MORE THAN 10 FT FROM PRINCIPAL FACADE PER RDS D.1.d.(1) ENTRY DOOR NO TALLER THAN 8FT PER RDS D.2.c ENTRY PORCH NOT MORE THAN ONE-STORY IN HEIGHT PER RDS D.3.c GROUP OF WINDOWS ON FRONT FACADE PER RDS E.1.d.(2) NO STREET-FACING WINDOWS MORE THAN ONE-STORY PER RDS E.2.c EXTERIOR MATERIALS CONSISTENT ON ALL SIDES & TRUE TO CHARACTERISTICS PER RDS E.5.c R-6 ZONE DISTRICT HEIGHT LIMIT 25' 60% + OF FRONT FACADE WITHIN REQ'D DISTANCE OF MINIMUM SETBACK PER RDS B.3.c LIGHTWELL PER RDS E.4.c & IRC R310.1 FRONT PORCH PER PER 26.575.020.D.5 VERTICAL CIRCULATION NOT COUNTED ON UPPER MOST FLOOR PER 26.575.020.D.2.a PATIO AT OR WITHIN 6" OF FINISHED GRADE PER 26.575.020.D.6 ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.j PROPOSED DRIVEWAY WITHIN 30" OF FINISHED GRADE PER 26.575.020.E.5.q TOP MOST PORTION OF ROOF PER 26.575.020.F.2 CHIMNEY PROTECTION <10' FROM HEIGHT OFBUILDING CONNECTION PER 26.575.020.F.4.a SAFETY GLAZING RADON VENT PIPE EXISTING HORIZONTAL WOOD SIDING TO BE REPAINTED VERTICAL METAL SIDING TBD STANDING SEAM ROOF SYNTHETIC SHINGLE EMERGENCY ESCAPE AND RESCUE DOORS PER IRC R310.3 DWELLING-GARAGE FIRE SEPARATIONPER IRC R302.6 BARS, GRILLS, COVERS, SCREENS OVER EMERGENCY ESCAPES AND RESCUE OPENING PER RDS 310.4 LINE OF EXTERIOR WALL BELOW DRIVEWAY TO REMAIN EXTERIOR DECK MATERIAL TBD HANDRAIL PER IRC 311.7.8 & 311.7.8.1 MIN HEIGHT 34" AC UNITS GUTTER SNOW STOPS / SNOW FENCE PANEL TO BE NON-LOCKING FLIP-UP GRATE & REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION DOWNSPOUT PROPOSED GRADE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE LIGHTWELL MINIMUM OPENING AREA PER IRC R310.2.1SNOWMELT PER IRC 310 LIFE & SAFETY DWELLING-GARAGE OPENING ANDPENETRATION PROTECTION PER IRC R302.5 GAS + ELECTRIC METERS ROOF OVERHANG GLASS GUARD SAFETY GLAZED PER IRC 308.4 &SUPPORT POINT LOAD PER IRC 301.5 DRYER FLUE VENT; TYP LINE OF FOUNDATION BELOW FALL PROTECTION PROVIDED PER R612.2 1/4" PER 1' SLOPE GAS LANTERNS BEVOLO CONTEMPORARY SERIES ASPHAULT SHINGLES TO BE REPLACED BRICK TO MATCH PAVER TBD LINE OF PROPOSED GRADE 2" CURB TYP. HOSE BIB LADDER AND STEPS PER IRC R310.2.3.1 1/2 POINT FROM EAVE TO RIDGE 1/3 POINT FROM EAVE TO RIDGE DRAWING ISSUANCE INDEX ID 01 02 03 NAME SCHEMATIC APPROVAL DD RDS REVIEW ISSUED DATE 10/2/17, 11:34 AM 10/2/17, 11:35 AM 10/2/17, 12:02 PM COPYRIGHT 10/2/17 KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION Z-201X HEIGHTS 10/2/17 RJL/JM/IS 1712.00 Aspen CO 81611 614 W NORTH ST Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Basalt: 104 Midland Ave, #202 Basalt, CO 81612 forumphi.com p: 970.279.4157 f: 866.770.5585 273512112006 7/10/17, 5:00 PM 9/1/17, 10:00 AM 2/27/2018 6 5 4 2 9' - 0 " 8'- 6 " 1' - 0 " 12 ' - 7 9/ 3 2 " 2' - 7 9/1 6 " EXISTING GRADE EXISTING MAIN LEVEL T.O. PLY 100'-0" = 7891'-9" EXISTING UPPER LEVEL T.O. PLY 109'-6" T.O. EXISTING RIDGE 124'-8 1/2" T.O. EXISTING RIDGE 127'-0" EXISTING UPPER LEVEL STEP T.O. PLY 108'-6" EXISTING LOWER LEVEL T.O. CONC. 91'-0" PR O P E R T Y L I N E SE T B A C K L I N E PR O P E R T Y L I N E SE T B A C K L I N E 2'- 3 3/8 " T.O. EXISTING RIDGE 122'-1 9/32" 1.) EXISTING FRAMING & SHEATHING TO REMAIN AT AREAS NOT SHOWN AS DEMOLISHED. TYPICAL. 2.) ALL DIMENSIONS TO EXISTING WALLS TO BE VERIFIED IN FIELD. TYPICAL. 3.) EXISTING RIDGE HEIGHTS TO REMAIN. 4.) ALL EXTERIOR MATERIALS TO REMAIN AND TO BE RE-FINISHED UNLESS NOTED OTHERWISE. 5.) ALL EXISTING WINDOWS AND EXTERIOR DOORS TO BE REPLACED. VERIFY IN FILED PRIOR TO ALL SHOP DRAWING APPROVALS. 6.) VERIFY ALL EXISTING & PROPOSED SPOT ELEVATIONS IN FIELD. PROJECT 100'-0" IS IN RELATION TO EXISTING TOP OF PLYWOOD ON THE MAIN LEVEL. GENERAL PLAN NOTES EXISTING TO REMAIN TO BE DEMOLISHED NEW WALL WALL LEGEND 0 2'4'8'SCALE: 1/4" = 1'-0"2 EXISTING WEST ELEVATION STEVEN WILSON 402127 STA T E OF COLO R A D O L I C E NSED AR C H ITECT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t BUILDING NO GREATER THAN 50FT IN DEPTH, UNLESS ACCESSORY & SEPARATE FROM MAIN PER RDS B.1.d.(1) VEHICULAR ACCESS VIA ALLEY OR PRIVATE STREET PER RDS C.1.c STREET FACING ENTRY DOOR NOT SET BACK MORE THAN 10 FT FROM PRINCIPAL FACADE PER RDS D.1.d.(1) ENTRY DOOR NO TALLER THAN 8FT PER RDS D.2.c ENTRY PORCH NOT MORE THAN ONE-STORY IN HEIGHT PER RDS D.3.c GROUP OF WINDOWS ON FRONT FACADE PER RDS E.1.d.(2) NO STREET-FACING WINDOWS MORE THAN ONE-STORY PER RDS E.2.c EXTERIOR MATERIALS CONSISTENT ON ALL SIDES & TRUE TO CHARACTERISTICS PER RDS E.5.c R-6 ZONE DISTRICT HEIGHT LIMIT 25' 60% + OF FRONT FACADE WITHIN REQ'D DISTANCE OF MINIMUM SETBACK PER RDS B.3.c LIGHTWELL PER RDS E.4.c & IRC R310.1 FRONT PORCH PER PER 26.575.020.D.5 VERTICAL CIRCULATION NOT COUNTED ON UPPER MOST FLOOR PER 26.575.020.D.2.a PATIO AT OR WITHIN 6" OF FINISHED GRADE PER 26.575.020.D.6 ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.j PROPOSED DRIVEWAY WITHIN 30" OF FINISHED GRADE PER 26.575.020.E.5.q TOP MOST PORTION OF ROOF PER 26.575.020.F.2 CHIMNEY PROTECTION <10' FROM HEIGHT OFBUILDING CONNECTION PER 26.575.020.F.4.a SAFETY GLAZING RADON VENT PIPE EXISTING HORIZONTAL WOOD SIDING TO BE REPAINTED VERTICAL METAL SIDING TBD STANDING SEAM ROOF SYNTHETIC SHINGLE EMERGENCY ESCAPE AND RESCUE DOORS PER IRC R310.3 DWELLING-GARAGE FIRE SEPARATIONPER IRC R302.6 BARS, GRILLS, COVERS, SCREENS OVER EMERGENCY ESCAPES AND RESCUE OPENING PER RDS 310.4 LINE OF EXTERIOR WALL BELOW DRIVEWAY TO REMAIN EXTERIOR DECK MATERIAL TBD HANDRAIL PER IRC 311.7.8 & 311.7.8.1 MIN HEIGHT 34" AC UNITS GUTTER SNOW STOPS / SNOW FENCE PANEL TO BE NON-LOCKING FLIP-UP GRATE & REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION DOWNSPOUT PROPOSED GRADE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE LIGHTWELL MINIMUM OPENING AREA PER IRC R310.2.1SNOWMELT PER IRC 310 LIFE & SAFETY DWELLING-GARAGE OPENING ANDPENETRATION PROTECTION PER IRC R302.5 GAS + ELECTRIC METERS ROOF OVERHANG GLASS GUARD SAFETY GLAZED PER IRC 308.4 &SUPPORT POINT LOAD PER IRC 301.5 DRYER FLUE VENT; TYP LINE OF FOUNDATION BELOW FALL PROTECTION PROVIDED PER R612.2 1/4" PER 1' SLOPE GAS LANTERNS BEVOLO CONTEMPORARY SERIES ASPHAULT SHINGLES TO BE REPLACED BRICK TO MATCH PAVER TBD LINE OF PROPOSED GRADE 2" CURB TYP. HOSE BIB LADDER AND STEPS PER IRC R310.2.3.1 1/2 POINT FROM EAVE TO RIDGE 1/3 POINT FROM EAVE TO RIDGE DRAWING ISSUANCE INDEX ID 01 02 03 NAME SCHEMATIC APPROVAL DD RDS REVIEW ISSUED DATE 10/2/17, 11:34 AM 10/2/17, 11:35 AM 10/2/17, 12:02 PM COPYRIGHT 10/2/17 KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION Z-202X HEIGHTS 10/2/17 RJL/JM/IS 1712.00 Aspen CO 81611 614 W NORTH ST Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Basalt: 104 Midland Ave, #202 Basalt, CO 81612 forumphi.com p: 970.279.4157 f: 866.770.5585 273512112006 7/10/17, 5:00 PM 9/1/17, 10:00 AM 2/27/2018 2 3 4 5 6 9' - 0 " 8'- 6 " 1' - 0 " 12 ' - 7 9/ 3 2 " 2' - 7 9/1 6 " EXISTING GRADE EXISTING MAIN LEVEL T.O. PLY 100'-0" = 7891'-9" EXISTING UPPER LEVEL T.O. PLY 109'-6" T.O. EXISTING RIDGE 124'-8 1/2" T.O. EXISTING RIDGE 127'-0" EXISTING UPPER LEVEL STEP T.O. PLY 108'-6" EXISTING LOWER LEVEL T.O. CONC. 91'-0" 2'- 3 3/8 " T.O. EXISTING RIDGE 122'-1 9/32" PR O P E R T Y L I N E SE T B A C K L I N E PR O P E R T Y L I N E SE T B A C K L I N E 1.) EXISTING FRAMING & SHEATHING TO REMAIN AT AREAS NOT SHOWN AS DEMOLISHED. TYPICAL. 2.) ALL DIMENSIONS TO EXISTING WALLS TO BE VERIFIED IN FIELD. TYPICAL. 3.) EXISTING RIDGE HEIGHTS TO REMAIN. 4.) ALL EXTERIOR MATERIALS TO REMAIN AND TO BE RE-FINISHED UNLESS NOTED OTHERWISE. 5.) ALL EXISTING WINDOWS AND EXTERIOR DOORS TO BE REPLACED. VERIFY IN FILED PRIOR TO ALL SHOP DRAWING APPROVALS. 6.) VERIFY ALL EXISTING & PROPOSED SPOT ELEVATIONS IN FIELD. PROJECT 100'-0" IS IN RELATION TO EXISTING TOP OF PLYWOOD ON THE MAIN LEVEL. GENERAL PLAN NOTES EXISTING TO REMAIN TO BE DEMOLISHED NEW WALL WALL LEGEND 0 2'4'8'SCALE: 1/4" = 1'-0"4 EXISTING EAST ELEVATION STEVEN WILSON 402127 STA T E OF COLO R A D O L I C E NSED AR C H ITECT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t BUILDING NO GREATER THAN 50FT IN DEPTH, UNLESS ACCESSORY & SEPARATE FROM MAIN PER RDS B.1.d.(1) VEHICULAR ACCESS VIA ALLEY OR PRIVATE STREET PER RDS C.1.c STREET FACING ENTRY DOOR NOT SET BACK MORE THAN 10 FT FROM PRINCIPAL FACADE PER RDS D.1.d.(1) ENTRY DOOR NO TALLER THAN 8FT PER RDS D.2.c ENTRY PORCH NOT MORE THAN ONE-STORY IN HEIGHT PER RDS D.3.c GROUP OF WINDOWS ON FRONT FACADE PER RDS E.1.d.(2) NO STREET-FACING WINDOWS MORE THAN ONE-STORY PER RDS E.2.c EXTERIOR MATERIALS CONSISTENT ON ALL SIDES & TRUE TO CHARACTERISTICS PER RDS E.5.c R-6 ZONE DISTRICT HEIGHT LIMIT 25' 60% + OF FRONT FACADE WITHIN REQ'D DISTANCE OF MINIMUM SETBACK PER RDS B.3.c LIGHTWELL PER RDS E.4.c & IRC R310.1 FRONT PORCH PER PER 26.575.020.D.5 VERTICAL CIRCULATION NOT COUNTED ON UPPER MOST FLOOR PER 26.575.020.D.2.a PATIO AT OR WITHIN 6" OF FINISHED GRADE PER 26.575.020.D.6 ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.j PROPOSED DRIVEWAY WITHIN 30" OF FINISHED GRADE PER 26.575.020.E.5.q TOP MOST PORTION OF ROOF PER 26.575.020.F.2 CHIMNEY PROTECTION <10' FROM HEIGHT OFBUILDING CONNECTION PER 26.575.020.F.4.a SAFETY GLAZING RADON VENT PIPE EXISTING HORIZONTAL WOOD SIDING TO BE REPAINTED VERTICAL METAL SIDING TBD STANDING SEAM ROOF SYNTHETIC SHINGLE EMERGENCY ESCAPE AND RESCUE DOORS PER IRC R310.3 DWELLING-GARAGE FIRE SEPARATIONPER IRC R302.6 BARS, GRILLS, COVERS, SCREENS OVER EMERGENCY ESCAPES AND RESCUE OPENING PER RDS 310.4 LINE OF EXTERIOR WALL BELOW DRIVEWAY TO REMAIN EXTERIOR DECK MATERIAL TBD HANDRAIL PER IRC 311.7.8 & 311.7.8.1 MIN HEIGHT 34" AC UNITS GUTTER SNOW STOPS / SNOW FENCE PANEL TO BE NON-LOCKING FLIP-UP GRATE & REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION DOWNSPOUT PROPOSED GRADE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE LIGHTWELL MINIMUM OPENING AREA PER IRC R310.2.1SNOWMELT PER IRC 310 LIFE & SAFETY DWELLING-GARAGE OPENING ANDPENETRATION PROTECTION PER IRC R302.5 GAS + ELECTRIC METERS ROOF OVERHANG GLASS GUARD SAFETY GLAZED PER IRC 308.4 &SUPPORT POINT LOAD PER IRC 301.5 DRYER FLUE VENT; TYP LINE OF FOUNDATION BELOW FALL PROTECTION PROVIDED PER R612.2 1/4" PER 1' SLOPE GAS LANTERNS BEVOLO CONTEMPORARY SERIES ASPHAULT SHINGLES TO BE REPLACED BRICK TO MATCH PAVER TBD LINE OF PROPOSED GRADE 2" CURB TYP. HOSE BIB LADDER AND STEPS PER IRC R310.2.3.1 1/2 POINT FROM EAVE TO RIDGE 1/3 POINT FROM EAVE TO RIDGE DRAWING ISSUANCE INDEX ID 01 02 03 NAME SCHEMATIC APPROVAL DD RDS REVIEW ISSUED DATE 10/2/17, 11:34 AM 10/2/17, 11:35 AM 10/2/17, 12:02 PM COPYRIGHT 10/2/17 KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION Z-203X HEIGHTS 10/2/17 RJL/JM/IS 1712.00 Aspen CO 81611 614 W NORTH ST Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Basalt: 104 Midland Ave, #202 Basalt, CO 81612 forumphi.com p: 970.279.4157 f: 866.770.5585 273512112006 7/10/17, 5:00 PM 9/1/17, 10:00 AM 2/27/2018 001 002 00 3 00 4 007 B 007 A A 010A 009 A001 A 008 A 005 A 004 A 003 A 002A 001 A W CD 55'-6" 5'-01/8"37'-107/8"12'-7"3'-8" 8"8"3'-0"8"11'-61/4"31/2"5'-11/4"31/2"20'-03/8"8"11'-11"8"3'-0"8" 8" 9'- 1 0 1/ 4 " 8" 4' - 1 1 " 8" 7'- 7 " 8" 4' - 1 0 " 8" 2' - 3 " 8" 55'-6" 12'-21/8"16'-87/8"26'-7" 8" 3' - 0 " 8" 10 ' - 9 3/4 " 31/ 2 " 5' - 2 1/2 " 31/ 2 " 15 ' - 6 " 8" 3' - 0 " 8" 8"10'-101/8"8" 31/2" 15'-45/8"8"25'-11"8" 40 ' - 9 1/ 4 " 3' - 8 " 33 ' - 5 1/4 " 3' - 8 " 33 ' - 5 1/ 4 " 10 ' - 6 1/ 4 " 5' - 7 " 8'- 1 1 " 5' - 6 " 2' - 1 1 " 3' - 0 " 3'-0"3' - 0 " 3'-0" T.O. CONC.91'-0" T.O. FF91'-2" T.O. CONC.91'-0" T.O. CONC.91'-0" T.O. FF91'-2" T.O. CONC.91'-0" T.O. FF91'-2" 26 26 2626 27 9 27 9 27 9 51 PROPERTY LIN E SETBACK LINE PR O P E R T Y L I N E SE T B A C K L I N E PROPERTY LIN E SETBACK LINE PR O P E R T Y L I N E 5' R E A R S E T B A C K L I N E 10 ' R E A R S E T B A C K L I N E 16 ' - 3 5/ 8 " 11 ' - 1 0 5/8 " 5' - 6 7/8 " UP MEDIA 005 MECH/STORAGE 010 BEDROOM 4 006 LAUNDRY 009 BEDROOM 2 003 BEDROOM 1 001 BATH 1 002 BATH 2 004 BATH 3 007 BEDROOM 3 008 4 Z-203 1 Z-201 2 Z-202 3 Z-201 2 2 3 3 4 4 5 5 6 6 E E D D B B A A 1 1 C C 1.) EXISTING FRAMING & SHEATHING TO REMAIN AT AREAS NOT SHOWN AS DEMOLISHED. TYPICAL. 2.) ALL DIMENSIONS TO EXISTING WALLS TO BE VERIFIED IN FIELD. TYPICAL. 3.) EXISTING RIDGE HEIGHTS TO REMAIN. 4.) ALL EXTERIOR MATERIALS TO REMAIN AND TO BE RE-FINISHED UNLESS NOTED OTHERWISE. 5.) ALL EXISTING WINDOWS AND EXTERIOR DOORS TO BE REPLACED. VERIFY IN FILED PRIOR TO ALL SHOP DRAWING APPROVALS. 6.) VERIFY ALL EXISTING & PROPOSED SPOT ELEVATIONS IN FIELD. PROJECT 100'-0" IS IN RELATION TO EXISTING TOP OF PLYWOOD ON THE MAIN LEVEL. GENERAL PLAN NOTES EXISTING TO REMAIN TO BE DEMOLISHED NEW WALL WALL LEGEND N02'4'8'SCALE: 1/4" = 1'-0" PROPOSED LOWER LEVEL STEVEN WILSON 402127 STA T E OF COLO R A D O L I C E NSED AR C H ITECT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t BUILDING NO GREATER THAN 50FT IN DEPTH, UNLESS ACCESSORY & SEPARATE FROM MAIN PER RDS B.1.d.(1) VEHICULAR ACCESS VIA ALLEY OR PRIVATE STREET PER RDS C.1.c STREET FACING ENTRY DOOR NOT SET BACK MORE THAN 10 FT FROM PRINCIPAL FACADE PER RDS D.1.d.(1) ENTRY DOOR NO TALLER THAN 8FT PER RDS D.2.c ENTRY PORCH NOT MORE THAN ONE-STORY IN HEIGHT PER RDS D.3.c GROUP OF WINDOWS ON FRONT FACADE PER RDS E.1.d.(2) NO STREET-FACING WINDOWS MORE THAN ONE-STORY PER RDS E.2.c EXTERIOR MATERIALS CONSISTENT ON ALL SIDES & TRUE TO CHARACTERISTICS PER RDS E.5.c R-6 ZONE DISTRICT HEIGHT LIMIT 25' 60% + OF FRONT FACADE WITHIN REQ'D DISTANCE OF MINIMUM SETBACK PER RDS B.3.c LIGHTWELL PER RDS E.4.c & IRC R310.1 FRONT PORCH PER PER 26.575.020.D.5 VERTICAL CIRCULATION NOT COUNTED ON UPPER MOST FLOOR PER 26.575.020.D.2.a PATIO AT OR WITHIN 6" OF FINISHED GRADE PER 26.575.020.D.6 ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.j PROPOSED DRIVEWAY WITHIN 30" OF FINISHED GRADE PER 26.575.020.E.5.q TOP MOST PORTION OF ROOF PER 26.575.020.F.2 CHIMNEY PROTECTION <10' FROM HEIGHT OFBUILDING CONNECTION PER 26.575.020.F.4.a SAFETY GLAZING RADON VENT PIPE EXISTING HORIZONTAL WOOD SIDING TO BE REPAINTED VERTICAL METAL SIDING TBD STANDING SEAM ROOF SYNTHETIC SHINGLE EMERGENCY ESCAPE AND RESCUE DOORS PER IRC R310.3 DWELLING-GARAGE FIRE SEPARATIONPER IRC R302.6 BARS, GRILLS, COVERS, SCREENS OVER EMERGENCY ESCAPES AND RESCUE OPENING PER RDS 310.4 LINE OF EXTERIOR WALL BELOW DRIVEWAY TO REMAIN EXTERIOR DECK MATERIAL TBD HANDRAIL PER IRC 311.7.8 & 311.7.8.1 MIN HEIGHT 34" AC UNITS GUTTER SNOW STOPS / SNOW FENCE PANEL TO BE NON-LOCKING FLIP-UP GRATE & REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION DOWNSPOUT PROPOSED GRADE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE LIGHTWELL MINIMUM OPENING AREA PER IRC R310.2.1SNOWMELT PER IRC 310 LIFE & SAFETY DWELLING-GARAGE OPENING ANDPENETRATION PROTECTION PER IRC R302.5 GAS + ELECTRIC METERS ROOF OVERHANG GLASS GUARD SAFETY GLAZED PER IRC 308.4 &SUPPORT POINT LOAD PER IRC 301.5 DRYER FLUE VENT; TYP LINE OF FOUNDATION BELOW FALL PROTECTION PROVIDED PER R612.2 1/4" PER 1' SLOPE GAS LANTERNS BEVOLO CONTEMPORARY SERIES ASPHAULT SHINGLES TO BE REPLACED BRICK TO MATCH PAVER TBD LINE OF PROPOSED GRADE 2" CURB TYP. HOSE BIB LADDER AND STEPS PER IRC R310.2.3.1 1/2 POINT FROM EAVE TO RIDGE 1/3 POINT FROM EAVE TO RIDGE DRAWING ISSUANCE INDEX ID 01 02 03 NAME SCHEMATIC APPROVAL DD RDS REVIEW ISSUED DATE 10/2/17, 11:34 AM 10/2/17, 11:35 AM 10/2/17, 12:02 PM COPYRIGHT 10/2/17 KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION Z-101 PROPOSED LOWER LEVEL 10/2/17 RJL/JM/IS 1712.00 Aspen CO 81611 614 W NORTH ST Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Basalt: 104 Midland Ave, #202 Basalt, CO 81612 forumphi.com p: 970.279.4157 f: 866.770.5585 273512112006 7/10/17, 5:00 PM 9/1/17, 10:00 AM 2/27/2018 LINE OF ROOF ABOVE LINE OF WALL ABOVE 104 A 114 11 5 110 109 10 8 10 7 106 105104103 116 101 B 113 101 A 11 7 10 2 10 1 111112 DW RG F TC 59'-8" 4'-2"42'-11"12'-7" 51/2"3'-81/2"51/2"27'-103/4" 31/2" 13'-93/4"51/2"12'-11/2"51/2" 33 ' - 5 1/4 " 10 ' - 6 1/ 4 " 20 ' - 0 " 2' - 1 1 " 51/ 2 " 10 ' - 0 3/ 4 " 51/2 " 19 ' - 1 " 51/ 2 " 2'- 5 1/2 " 51/2 " 59'-8" 4'-2"3'-77/8"25'-31/8"26'-7" 51/2"3'-81/2"51/2"3'-23/8"51/2"5'-05/8"31/2"1'-87/8"31/2"16'-115/8"51/2"26'-11/2"51/2" 33 ' - 5 1/ 4 " 3'- 3 1/2 " 10 ' - 0 1/4 " 3' - 3 1/ 2 " 16 ' - 1 0 " 51/2 " 2' - 1 0 " 51/ 2 " 9'- 1 1/4 " 51/ 2 " 2' - 1 0 " 51/2 " 16 ' - 4 1/2 " 51/2 " 2'-03/8"8'-91/4"8'-91/4"5'-31/4"3'-05/8"7'-6"6'-33/4"6'-03/4"6'-03/4"1'-11"1'-91/2" 1'-11"1'-91/2"5'-6"4'-0"4'-0"3'-55/8" 4'- 6 5/8 " 4'- 6 5/8 " 3' - 4 1/ 2 " 4' - 1 1 " 4'- 1 1 " 3'- 2 " 7'-05/8"19'-07/8" T.O. PLY100'-0" T.O. FF100'-2" T.O. PLY100'-0"T.O. PLY100'-0" T.O. CONC.99'-11 1/2"T.O. PLY100'-0" T.O. FF100'-2" T.O. FF100'-2"T.O. FF100'-2" 4 Z-203 1 Z-201 2 Z-202 3 Z-201 27 9 28 29 9 27 28 29 5 13 53 53 27 28 9 29 EXISTING DRIVEWAY PROPERTY LIN E SETBACK LINE PR O P E R T Y L I N E SE T B A C K L I N E PROPERTY LIN E SETBACK LINE PR O P E R T Y L I N E 5' R E A R S E T B A C K L I N E 10 ' R E A R S E T B A C K L I N E 2'- 4 5/ 8 " 11 ' - 1 0 5/8 " 2' - 3 7/8 " UP DN DINING 103 KITCHEN 104 GARAGE 105 LIVING ROOM 107 FAMILY ROOM 106 PWDR 102 ENTRY 101 2 2 3 3 4 4 5 5 6 6 E E D D B B A A 1 1 C C 1.) EXISTING FRAMING & SHEATHING TO REMAIN AT AREAS NOT SHOWN AS DEMOLISHED. TYPICAL. 2.) ALL DIMENSIONS TO EXISTING WALLS TO BE VERIFIED IN FIELD. TYPICAL. 3.) EXISTING RIDGE HEIGHTS TO REMAIN. 4.) ALL EXTERIOR MATERIALS TO REMAIN AND TO BE RE-FINISHED UNLESS NOTED OTHERWISE. 5.) ALL EXISTING WINDOWS AND EXTERIOR DOORS TO BE REPLACED. VERIFY IN FILED PRIOR TO ALL SHOP DRAWING APPROVALS. 6.) VERIFY ALL EXISTING & PROPOSED SPOT ELEVATIONS IN FIELD. PROJECT 100'-0" IS IN RELATION TO EXISTING TOP OF PLYWOOD ON THE MAIN LEVEL. GENERAL PLAN NOTES EXISTING TO REMAIN TO BE DEMOLISHED NEW WALL WALL LEGEND N02'4'8'SCALE: 1/4" = 1'-0" PROPOSED MAIN LEVEL STEVEN WILSON 402127 STA T E OF COLO R A D O L I C E NSED AR C H ITECT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t BUILDING NO GREATER THAN 50FT IN DEPTH, UNLESS ACCESSORY & SEPARATE FROM MAIN PER RDS B.1.d.(1) VEHICULAR ACCESS VIA ALLEY OR PRIVATE STREET PER RDS C.1.c STREET FACING ENTRY DOOR NOT SET BACK MORE THAN 10 FT FROM PRINCIPAL FACADE PER RDS D.1.d.(1) ENTRY DOOR NO TALLER THAN 8FT PER RDS D.2.c ENTRY PORCH NOT MORE THAN ONE-STORY IN HEIGHT PER RDS D.3.c GROUP OF WINDOWS ON FRONT FACADE PER RDS E.1.d.(2) NO STREET-FACING WINDOWS MORE THAN ONE-STORY PER RDS E.2.c EXTERIOR MATERIALS CONSISTENT ON ALL SIDES & TRUE TO CHARACTERISTICS PER RDS E.5.c R-6 ZONE DISTRICT HEIGHT LIMIT 25' 60% + OF FRONT FACADE WITHIN REQ'D DISTANCE OF MINIMUM SETBACK PER RDS B.3.c LIGHTWELL PER RDS E.4.c & IRC R310.1 FRONT PORCH PER PER 26.575.020.D.5 VERTICAL CIRCULATION NOT COUNTED ON UPPER MOST FLOOR PER 26.575.020.D.2.a PATIO AT OR WITHIN 6" OF FINISHED GRADE PER 26.575.020.D.6 ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.j PROPOSED DRIVEWAY WITHIN 30" OF FINISHED GRADE PER 26.575.020.E.5.q TOP MOST PORTION OF ROOF PER 26.575.020.F.2 CHIMNEY PROTECTION <10' FROM HEIGHT OFBUILDING CONNECTION PER 26.575.020.F.4.a SAFETY GLAZING RADON VENT PIPE EXISTING HORIZONTAL WOOD SIDING TO BE REPAINTED VERTICAL METAL SIDING TBD STANDING SEAM ROOF SYNTHETIC SHINGLE EMERGENCY ESCAPE AND RESCUE DOORS PER IRC R310.3 DWELLING-GARAGE FIRE SEPARATIONPER IRC R302.6 BARS, GRILLS, COVERS, SCREENS OVER EMERGENCY ESCAPES AND RESCUE OPENING PER RDS 310.4 LINE OF EXTERIOR WALL BELOW DRIVEWAY TO REMAIN EXTERIOR DECK MATERIAL TBD HANDRAIL PER IRC 311.7.8 & 311.7.8.1 MIN HEIGHT 34" AC UNITS GUTTER SNOW STOPS / SNOW FENCE PANEL TO BE NON-LOCKING FLIP-UP GRATE & REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION DOWNSPOUT PROPOSED GRADE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE LIGHTWELL MINIMUM OPENING AREA PER IRC R310.2.1SNOWMELT PER IRC 310 LIFE & SAFETY DWELLING-GARAGE OPENING ANDPENETRATION PROTECTION PER IRC R302.5 GAS + ELECTRIC METERS ROOF OVERHANG GLASS GUARD SAFETY GLAZED PER IRC 308.4 &SUPPORT POINT LOAD PER IRC 301.5 DRYER FLUE VENT; TYP LINE OF FOUNDATION BELOW FALL PROTECTION PROVIDED PER R612.2 1/4" PER 1' SLOPE GAS LANTERNS BEVOLO CONTEMPORARY SERIES ASPHAULT SHINGLES TO BE REPLACED BRICK TO MATCH PAVER TBD LINE OF PROPOSED GRADE 2" CURB TYP. HOSE BIB LADDER AND STEPS PER IRC R310.2.3.1 1/2 POINT FROM EAVE TO RIDGE 1/3 POINT FROM EAVE TO RIDGE DRAWING ISSUANCE INDEX ID 01 02 03 NAME SCHEMATIC APPROVAL DD RDS REVIEW ISSUED DATE 10/2/17, 11:34 AM 10/2/17, 11:35 AM 10/2/17, 12:02 PM COPYRIGHT 10/2/17 KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION Z-102 PROPOSED MAIN LEVEL 10/2/17 RJL/JM/IS 1712.00 Aspen CO 81611 614 W NORTH ST Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Basalt: 104 Midland Ave, #202 Basalt, CO 81612 forumphi.com p: 970.279.4157 f: 866.770.5585 273512112006 7/10/17, 5:00 PM 9/1/17, 10:00 AM 2/27/2018 20 5 20 6 21 0 209208 212 20 2 20 1 203 206 A 207 A 208 B 207 201B201A A 205 A 203A A 209 A A 206 B 211 204 4 Z-203 1 Z-201 2 Z-202 3 Z-201 52'-41/2" 4'-2"42'-11"5'-31/2" 51/2"3'-81/2"51/2"15'-85/8"31/2"5'-55/8"31/2"6'-11/2"31/2"13'-93/4"51/2"4'-10"51/2" 33 ' - 5 1/4 " 10 ' - 6 1/ 4 " 20 ' - 0 " 2' - 1 1 " 51/ 2 " 10 ' - 0 3/ 4 " 51/2 " 6' - 4 " 31/ 2 " 12 ' - 5 1/ 2 " 51/ 2 " 2'- 5 1/2 " 51/ 2 " 52'-41/2" 4'-2"10'-1"18'-10"19'-31/2" 51/2"3'-81/2"51/2"9'-71/2"51/2"17'-11"51/2"4'-111/4"31/2"13'-71/4"51/2" 33 ' - 5 1/ 4 " 3'- 3 1/2 " 10 ' - 0 1/4 " 3' - 3 1/ 2 " 16 ' - 1 0 " 51/2 " 2' - 1 0 " 51/2 " 9'- 1 1/4 " 51/2 " 2' - 1 0 " 51/ 2 " 16 ' - 4 1/2 " 51/ 2 " 1'-11"1'-91/2"3'-03/4" 3'-03/4" 1'-11"1'-91/2"1'-10"7'-91/2" 2'- 5 5/8 " 4'- 2 " 2' - 5 5/ 8 " 13'-93/4" 5'- 0 3/8 " 5' - 0 3/ 8 " 2'-55/8"2'-55/8"13'-77/8"4'-17/8"7'-71/4"5'-103/4" 4' - 6 7/ 8 " 8'- 8 " 2' - 1 1 1/ 2 " T.O. PLY109-6"T.O. PLY108'-6" T.O. FF108'-8" T.O. PLY109'-6" T.O. FF109'-8" T.O. DECK109'-4" T.O. FF109'-8" T.O. PLY108'-6" T.O. FF108'-8" T.O. PLY109'-6" T.O. FF109'-8"11 23 23 23 23 51 DECK PROPERTY LIN E SETBACK LINE PR O P E R T Y L I N E SE T B A C K L I N E PROPERTY LIN E SETBACK LINE PR O P E R T Y L I N E 5' R E A R S E T B A C K L I N E 10 ' R E A R S E T B A C K L I N E 2'- 4 5/ 8 " 11 ' - 1 0 5/8 " 2' - 3 7/8 " DN BEDROOM 5 206 BEDROOM 6 208 MASTER BEDROOM 201 SITTING ROOM 202 MASTER BATH 203 MASTER CLO 2 205 BATH 5 209 MASTER CLO 1 204 BATH 4 207 2 2 3 3 4 4 5 5 6 6 E E D D B B A A 1 1 C C 23 1.) EXISTING FRAMING & SHEATHING TO REMAIN AT AREAS NOT SHOWN AS DEMOLISHED. TYPICAL. 2.) ALL DIMENSIONS TO EXISTING WALLS TO BE VERIFIED IN FIELD. TYPICAL. 3.) EXISTING RIDGE HEIGHTS TO REMAIN. 4.) ALL EXTERIOR MATERIALS TO REMAIN AND TO BE RE-FINISHED UNLESS NOTED OTHERWISE. 5.) ALL EXISTING WINDOWS AND EXTERIOR DOORS TO BE REPLACED. VERIFY IN FILED PRIOR TO ALL SHOP DRAWING APPROVALS. 6.) VERIFY ALL EXISTING & PROPOSED SPOT ELEVATIONS IN FIELD. PROJECT 100'-0" IS IN RELATION TO EXISTING TOP OF PLYWOOD ON THE MAIN LEVEL. GENERAL PLAN NOTES EXISTING TO REMAIN TO BE DEMOLISHED NEW WALL WALL LEGEND N02'4'8'SCALE: 1/4" = 1'-0" PROPOSED UPPER LEVEL STEVEN WILSON 402127 STA T E OF COLO R A D O L I C E NSED AR C H ITECT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t BUILDING NO GREATER THAN 50FT IN DEPTH, UNLESS ACCESSORY & SEPARATE FROM MAIN PER RDS B.1.d.(1) VEHICULAR ACCESS VIA ALLEY OR PRIVATE STREET PER RDS C.1.c STREET FACING ENTRY DOOR NOT SET BACK MORE THAN 10 FT FROM PRINCIPAL FACADE PER RDS D.1.d.(1) ENTRY DOOR NO TALLER THAN 8FT PER RDS D.2.c ENTRY PORCH NOT MORE THAN ONE-STORY IN HEIGHT PER RDS D.3.c GROUP OF WINDOWS ON FRONT FACADE PER RDS E.1.d.(2) NO STREET-FACING WINDOWS MORE THAN ONE-STORY PER RDS E.2.c EXTERIOR MATERIALS CONSISTENT ON ALL SIDES & TRUE TO CHARACTERISTICS PER RDS E.5.c R-6 ZONE DISTRICT HEIGHT LIMIT 25' 60% + OF FRONT FACADE WITHIN REQ'D DISTANCE OF MINIMUM SETBACK PER RDS B.3.c LIGHTWELL PER RDS E.4.c & IRC R310.1 FRONT PORCH PER PER 26.575.020.D.5 VERTICAL CIRCULATION NOT COUNTED ON UPPER MOST FLOOR PER 26.575.020.D.2.a PATIO AT OR WITHIN 6" OF FINISHED GRADE PER 26.575.020.D.6 ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.j PROPOSED DRIVEWAY WITHIN 30" OF FINISHED GRADE PER 26.575.020.E.5.q TOP MOST PORTION OF ROOF PER 26.575.020.F.2 CHIMNEY PROTECTION <10' FROM HEIGHT OFBUILDING CONNECTION PER 26.575.020.F.4.a SAFETY GLAZING RADON VENT PIPE EXISTING HORIZONTAL WOOD SIDING TO BE REPAINTED VERTICAL METAL SIDING TBD STANDING SEAM ROOF SYNTHETIC SHINGLE EMERGENCY ESCAPE AND RESCUE DOORS PER IRC R310.3 DWELLING-GARAGE FIRE SEPARATIONPER IRC R302.6 BARS, GRILLS, COVERS, SCREENS OVER EMERGENCY ESCAPES AND RESCUE OPENING PER RDS 310.4 LINE OF EXTERIOR WALL BELOW DRIVEWAY TO REMAIN EXTERIOR DECK MATERIAL TBD HANDRAIL PER IRC 311.7.8 & 311.7.8.1 MIN HEIGHT 34" AC UNITS GUTTER SNOW STOPS / SNOW FENCE PANEL TO BE NON-LOCKING FLIP-UP GRATE & REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION DOWNSPOUT PROPOSED GRADE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE LIGHTWELL MINIMUM OPENING AREA PER IRC R310.2.1SNOWMELT PER IRC 310 LIFE & SAFETY DWELLING-GARAGE OPENING ANDPENETRATION PROTECTION PER IRC R302.5 GAS + ELECTRIC METERS ROOF OVERHANG GLASS GUARD SAFETY GLAZED PER IRC 308.4 &SUPPORT POINT LOAD PER IRC 301.5 DRYER FLUE VENT; TYP LINE OF FOUNDATION BELOW FALL PROTECTION PROVIDED PER R612.2 1/4" PER 1' SLOPE GAS LANTERNS BEVOLO CONTEMPORARY SERIES ASPHAULT SHINGLES TO BE REPLACED BRICK TO MATCH PAVER TBD LINE OF PROPOSED GRADE 2" CURB TYP. HOSE BIB LADDER AND STEPS PER IRC R310.2.3.1 1/2 POINT FROM EAVE TO RIDGE 1/3 POINT FROM EAVE TO RIDGE DRAWING ISSUANCE INDEX ID 01 02 03 NAME SCHEMATIC APPROVAL DD RDS REVIEW ISSUED DATE 10/2/17, 11:34 AM 10/2/17, 11:35 AM 10/2/17, 12:02 PM COPYRIGHT 10/2/17 KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION Z-103 PROPOSED UPPER LEVEL 10/2/17 RJL/JM/IS 1712.00 Aspen CO 81611 614 W NORTH ST Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Basalt: 104 Midland Ave, #202 Basalt, CO 81612 forumphi.com p: 970.279.4157 f: 866.770.5585 273512112006 7/10/17, 5:00 PM 9/1/17, 10:00 AM 2/27/2018 4 Z-203 1 Z-201 2 Z-202 3 Z-201 36 ' - 0 1/ 2 " 3' - 3 1/ 2 " 11 ' - 7 1/2 " 3' - 3 1/ 2 " 17 ' - 4 " 81/ 8 " 2' - 7 3/ 8 " 81/8 " 10 ' - 3 1/4 " 81/ 8 " 2'- 7 3/8 " 81/8 " 16 ' - 1 7/ 8 " 1' - 2 1/ 8 " 61'-31/4" 4'-2"10'-1"20'-51/4"19'-91/2"6'-91/2" 81/8"3'-57/8"81/8"9'-47/8"81/8"19'-1"81/8"18'-73/8"1'-21/8"6'-13/8"81/8" 35 ' - 6 1/ 2 " 10 ' - 6 1/4 " 21 ' - 7 1/4 " 3' - 5 " 81/8 " 9' - 1 0 1/8 " 81/ 8 " 20 ' - 3 " 81/8 " 2' - 2 7/ 8 " 1' - 2 1/ 8 " 61'-31/4" 4'-2"14'-63/8"16'-63/4"13'-111/8"5'-31/2"6'-91/2" 81/8"3'-57/8"81/8"43'-2"1'-21/8"4'-13/8"1'-21/8"6'-13/8"81/8" 51 PROPERTY LI N E SETBACK LINE PR O P E R T Y L I N E SE T B A C K L I N E PROPERTY LIN E SETBACK LINE PR O P E R T Y L I N E 5' R E A R S E T B A C K L I N E 10 ' R E A R S E T B A C K L I N E UPPER LEVEL DECK BELOW 2 2 3 3 4 4 5 5 6 6 E E D D B B A A 1 1 C C 12:12 12:12 12:12 12:12 12:12 6:12 6:12 6:12 4:12 12:12 12:12 12:12 12:12 1:12 1:12 23 23 14 23 23 12:12 12:12 12:12 6:12 6:12 35 23 23 1.) EXISTING FRAMING & SHEATHING TO REMAIN AT AREAS NOT SHOWN AS DEMOLISHED. TYPICAL. 2.) ALL DIMENSIONS TO EXISTING WALLS TO BE VERIFIED IN FIELD. TYPICAL. 3.) EXISTING RIDGE HEIGHTS TO REMAIN. 4.) ALL EXTERIOR MATERIALS TO REMAIN AND TO BE RE-FINISHED UNLESS NOTED OTHERWISE. 5.) ALL EXISTING WINDOWS AND EXTERIOR DOORS TO BE REPLACED. VERIFY IN FILED PRIOR TO ALL SHOP DRAWING APPROVALS. 6.) VERIFY ALL EXISTING & PROPOSED SPOT ELEVATIONS IN FIELD. PROJECT 100'-0" IS IN RELATION TO EXISTING TOP OF PLYWOOD ON THE MAIN LEVEL. GENERAL PLAN NOTES EXISTING TO REMAIN TO BE DEMOLISHED NEW ROOF ROOF DEMO LEGEND N02'4'8'SCALE: 1/4" = 1'-0" PROPOSED ROOF PLAN STEVEN WILSON 402127 STA T E OF COLO R A D O L I C E NSED AR C H ITECT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t BUILDING NO GREATER THAN 50FT IN DEPTH, UNLESS ACCESSORY & SEPARATE FROM MAIN PER RDS B.1.d.(1) VEHICULAR ACCESS VIA ALLEY OR PRIVATE STREET PER RDS C.1.c STREET FACING ENTRY DOOR NOT SET BACK MORE THAN 10 FT FROM PRINCIPAL FACADE PER RDS D.1.d.(1) ENTRY DOOR NO TALLER THAN 8FT PER RDS D.2.c ENTRY PORCH NOT MORE THAN ONE-STORY IN HEIGHT PER RDS D.3.c GROUP OF WINDOWS ON FRONT FACADE PER RDS E.1.d.(2) NO STREET-FACING WINDOWS MORE THAN ONE-STORY PER RDS E.2.c EXTERIOR MATERIALS CONSISTENT ON ALL SIDES & TRUE TO CHARACTERISTICS PER RDS E.5.c R-6 ZONE DISTRICT HEIGHT LIMIT 25' 60% + OF FRONT FACADE WITHIN REQ'D DISTANCE OF MINIMUM SETBACK PER RDS B.3.c LIGHTWELL PER RDS E.4.c & IRC R310.1 FRONT PORCH PER PER 26.575.020.D.5 VERTICAL CIRCULATION NOT COUNTED ON UPPER MOST FLOOR PER 26.575.020.D.2.a PATIO AT OR WITHIN 6" OF FINISHED GRADE PER 26.575.020.D.6 ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.j PROPOSED DRIVEWAY WITHIN 30" OF FINISHED GRADE PER 26.575.020.E.5.q TOP MOST PORTION OF ROOF PER 26.575.020.F.2 CHIMNEY PROTECTION <10' FROM HEIGHT OFBUILDING CONNECTION PER 26.575.020.F.4.a SAFETY GLAZING RADON VENT PIPE EXISTING HORIZONTAL WOOD SIDING TO BE REPAINTED VERTICAL METAL SIDING TBD STANDING SEAM ROOF SYNTHETIC SHINGLE EMERGENCY ESCAPE AND RESCUE DOORS PER IRC R310.3 DWELLING-GARAGE FIRE SEPARATIONPER IRC R302.6 BARS, GRILLS, COVERS, SCREENS OVER EMERGENCY ESCAPES AND RESCUE OPENING PER RDS 310.4 LINE OF EXTERIOR WALL BELOW DRIVEWAY TO REMAIN EXTERIOR DECK MATERIAL TBD HANDRAIL PER IRC 311.7.8 & 311.7.8.1 MIN HEIGHT 34" AC UNITS GUTTER SNOW STOPS / SNOW FENCE PANEL TO BE NON-LOCKING FLIP-UP GRATE & REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION DOWNSPOUT PROPOSED GRADE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE LIGHTWELL MINIMUM OPENING AREA PER IRC R310.2.1SNOWMELT PER IRC 310 LIFE & SAFETY DWELLING-GARAGE OPENING ANDPENETRATION PROTECTION PER IRC R302.5 GAS + ELECTRIC METERS ROOF OVERHANG GLASS GUARD SAFETY GLAZED PER IRC 308.4 &SUPPORT POINT LOAD PER IRC 301.5 DRYER FLUE VENT; TYP LINE OF FOUNDATION BELOW FALL PROTECTION PROVIDED PER R612.2 1/4" PER 1' SLOPE GAS LANTERNS BEVOLO CONTEMPORARY SERIES ASPHAULT SHINGLES TO BE REPLACED BRICK TO MATCH PAVER TBD LINE OF PROPOSED GRADE 2" CURB TYP. HOSE BIB LADDER AND STEPS PER IRC R310.2.3.1 1/2 POINT FROM EAVE TO RIDGE 1/3 POINT FROM EAVE TO RIDGE DRAWING ISSUANCE INDEX ID 01 02 03 NAME SCHEMATIC APPROVAL DD RDS REVIEW ISSUED DATE 10/2/17, 11:34 AM 10/2/17, 11:35 AM 10/2/17, 12:02 PM COPYRIGHT 10/2/17 KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION Z-104 PROPOSED ROOF PLAN 10/2/17 RJL/JM/IS 1712.00 Aspen CO 81611 614 W NORTH ST Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Basalt: 104 Midland Ave, #202 Basalt, CO 81612 forumphi.com p: 970.279.4157 f: 866.770.5585 273512112006 7/10/17, 5:00 PM 9/1/17, 10:00 AM 2/27/2018 E D B AC 9' - 0 " 8'- 6 " 1' - 0 " 12 ' - 7 9/ 3 2 " 2'- 7 9/1 6 " 17'-4"2'-7"13'-73/4" 115 205206 201202 10 14 32 7 117101102 9 13 6 5 8 4 18 7 7 56 29 27 58 29 27 58 61 61 60 61 28 28 EXISTING MAIN LEVEL T.O. PLY 100'-0" = 7891'-9" EXISTING UPPER LEVEL T.O. PLY 109'-6" EXISTING LOWER LEVEL T.O. CONC. 91'-0" T.O. EXISTING RIDGE 127'-0" EXISTING UPPER LEVEL STEP T.O. PLY 108'-6" 15 ' - 2 7/8 " 2'- 3 3/8 " SE T B A C K L I N E PR O P E R T Y L I N E SE T B A C K L I N E T.O. EXISTING RIDGE 124'-8 1/2" SGSG SGSG SGSGSGSG T.O. EXISTING RIDGE 122'-1 9/32" C 9' - 0 " 8'- 6 " 1' - 0 " 12 ' - 7 9/ 3 2 " 2'- 7 9/ 1 6 " 107108 29 26 9 28 18 210 10 56 58 61 60 10 6060 EXISTING MAIN LEVEL T.O. PLY 100'-0" = 7891'-9" EXISTING UPPER LEVEL T.O. PLY 109'-6" EXISTING LOWER LEVEL T.O. CONC. 91'-0" T.O. EXISTING RIDGE 127'-0" EXISTING UPPER LEVEL STEP T.O. PLY 108'-6" 2'- 3 3/8 " PR O P E R T Y L I N E SE T B A C K L I N E T.O. EXISTING RIDGE 124'-8 1/2" SGSG SG T.O. EXISTING RIDGE 122'-1 9/32" A B D E 1.) EXISTING FRAMING & SHEATHING TO REMAIN AT AREAS NOT SHOWN AS DEMOLISHED. TYPICAL. 2.) ALL DIMENSIONS TO EXISTING WALLS TO BE VERIFIED IN FIELD. TYPICAL. 3.) EXISTING RIDGE HEIGHTS TO REMAIN. 4.) ALL EXTERIOR MATERIALS TO REMAIN AND TO BE RE-FINISHED UNLESS NOTED OTHERWISE. 5.) ALL EXISTING WINDOWS AND EXTERIOR DOORS TO BE REPLACED. VERIFY IN FILED PRIOR TO ALL SHOP DRAWING APPROVALS. 6.) VERIFY ALL EXISTING & PROPOSED SPOT ELEVATIONS IN FIELD. PROJECT 100'-0" IS IN RELATION TO EXISTING TOP OF PLYWOOD ON THE MAIN LEVEL. GENERAL PLAN NOTES EXISTING TO REMAIN TO BE DEMOLISHED NEW WALL WALL LEGEND 0 2'4'8'SCALE: 1/4" = 1'-0"1 PROPOSED SOUTH ELEVATION 0 2'4'8'SCALE: 1/4" = 1'-0"3 PROPOSED NORTH ELEVATION STEVEN WILSON 402127 STA T E OF COLO R A D O L I C E NSED AR C H ITECT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t BUILDING NO GREATER THAN 50FT IN DEPTH, UNLESS ACCESSORY & SEPARATE FROM MAIN PER RDS B.1.d.(1) VEHICULAR ACCESS VIA ALLEY OR PRIVATE STREET PER RDS C.1.c STREET FACING ENTRY DOOR NOT SET BACK MORE THAN 10 FT FROM PRINCIPAL FACADE PER RDS D.1.d.(1) ENTRY DOOR NO TALLER THAN 8FT PER RDS D.2.c ENTRY PORCH NOT MORE THAN ONE-STORY IN HEIGHT PER RDS D.3.c GROUP OF WINDOWS ON FRONT FACADE PER RDS E.1.d.(2) NO STREET-FACING WINDOWS MORE THAN ONE-STORY PER RDS E.2.c EXTERIOR MATERIALS CONSISTENT ON ALL SIDES & TRUE TO CHARACTERISTICS PER RDS E.5.c R-6 ZONE DISTRICT HEIGHT LIMIT 25' 60% + OF FRONT FACADE WITHIN REQ'D DISTANCE OF MINIMUM SETBACK PER RDS B.3.c LIGHTWELL PER RDS E.4.c & IRC R310.1 FRONT PORCH PER PER 26.575.020.D.5 VERTICAL CIRCULATION NOT COUNTED ON UPPER MOST FLOOR PER 26.575.020.D.2.a PATIO AT OR WITHIN 6" OF FINISHED GRADE PER 26.575.020.D.6 ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.j PROPOSED DRIVEWAY WITHIN 30" OF FINISHED GRADE PER 26.575.020.E.5.q TOP MOST PORTION OF ROOF PER 26.575.020.F.2 CHIMNEY PROTECTION <10' FROM HEIGHT OFBUILDING CONNECTION PER 26.575.020.F.4.a SAFETY GLAZING RADON VENT PIPE EXISTING HORIZONTAL WOOD SIDING TO BE REPAINTED VERTICAL METAL SIDING TBD STANDING SEAM ROOF SYNTHETIC SHINGLE EMERGENCY ESCAPE AND RESCUE DOORS PER IRC R310.3 DWELLING-GARAGE FIRE SEPARATIONPER IRC R302.6 BARS, GRILLS, COVERS, SCREENS OVER EMERGENCY ESCAPES AND RESCUE OPENING PER RDS 310.4 LINE OF EXTERIOR WALL BELOW DRIVEWAY TO REMAIN EXTERIOR DECK MATERIAL TBD HANDRAIL PER IRC 311.7.8 & 311.7.8.1 MIN HEIGHT 34" AC UNITS GUTTER SNOW STOPS / SNOW FENCE PANEL TO BE NON-LOCKING FLIP-UP GRATE & REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION DOWNSPOUT PROPOSED GRADE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE LIGHTWELL MINIMUM OPENING AREA PER IRC R310.2.1SNOWMELT PER IRC 310 LIFE & SAFETY DWELLING-GARAGE OPENING ANDPENETRATION PROTECTION PER IRC R302.5 GAS + ELECTRIC METERS ROOF OVERHANG GLASS GUARD SAFETY GLAZED PER IRC 308.4 &SUPPORT POINT LOAD PER IRC 301.5 DRYER FLUE VENT; TYP LINE OF FOUNDATION BELOW FALL PROTECTION PROVIDED PER R612.2 1/4" PER 1' SLOPE GAS LANTERNS BEVOLO CONTEMPORARY SERIES ASPHAULT SHINGLES TO BE REPLACED BRICK TO MATCH PAVER TBD LINE OF PROPOSED GRADE 2" CURB TYP. HOSE BIB LADDER AND STEPS PER IRC R310.2.3.1 1/2 POINT FROM EAVE TO RIDGE 1/3 POINT FROM EAVE TO RIDGE DRAWING ISSUANCE INDEX ID 01 02 03 NAME SCHEMATIC APPROVAL DD RDS REVIEW ISSUED DATE 10/2/17, 11:34 AM 10/2/17, 11:35 AM 10/2/17, 12:02 PM COPYRIGHT 10/2/17 KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION Z-201 HEIGHTS 10/2/17 RJL/JM/IS 1712.00 Aspen CO 81611 614 W NORTH ST Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Basalt: 104 Midland Ave, #202 Basalt, CO 81612 forumphi.com p: 970.279.4157 f: 866.770.5585 273512112006 7/10/17, 5:00 PM 9/1/17, 10:00 AM 2/27/2018 9'- 0 " 8' - 6 " 1'- 0 " 12 ' - 7 9/3 2 " 2' - 7 9/ 1 6 " 116 203 204 103104105 207 208 106 209 13 6 10 9 26 32 9 29 18 10 56 28 58 58 60 61 60 28 29 EXISTING MAIN LEVEL T.O. PLY 100'-0" = 7891'-9" EXISTING UPPER LEVEL T.O. PLY 109'-6" EXISTING LOWER LEVEL T.O. CONC. 91'-0" T.O. EXISTING RIDGE 127'-0" EXISTING UPPER LEVEL STEP T.O. PLY 108'-6" 15 ' - 2 7/ 8 " 2' - 3 3/ 8 " T.O. EXISTING RIDGE 124'-8 1/2" SG SG SG SG SG SGSG T.O. EXISTING RIDGE122'-1 9/32" 6 5 4 2 1 PR O P E R T Y L I N E SE T B A C K L I N E PR O P E R T Y L I N E SE T B A C K L I N E 1.) EXISTING FRAMING & SHEATHING TO REMAIN AT AREAS NOT SHOWN AS DEMOLISHED. TYPICAL. 2.) ALL DIMENSIONS TO EXISTING WALLS TO BE VERIFIED IN FIELD. TYPICAL. 3.) EXISTING RIDGE HEIGHTS TO REMAIN. 4.) ALL EXTERIOR MATERIALS TO REMAIN AND TO BE RE-FINISHED UNLESS NOTED OTHERWISE. 5.) ALL EXISTING WINDOWS AND EXTERIOR DOORS TO BE REPLACED. VERIFY IN FILED PRIOR TO ALL SHOP DRAWING APPROVALS. 6.) VERIFY ALL EXISTING & PROPOSED SPOT ELEVATIONS IN FIELD. PROJECT 100'-0" IS IN RELATION TO EXISTING TOP OF PLYWOOD ON THE MAIN LEVEL. GENERAL PLAN NOTES EXISTING TO REMAIN TO BE DEMOLISHED NEW WALL WALL LEGEND 0 2'4'8'SCALE: 1/4" = 1'-0"2 PROPOSED WEST ELEVATION STEVEN WILSON 402127 STA T E OF COLO R A D O L I C E NSED AR C H ITECT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t BUILDING NO GREATER THAN 50FT IN DEPTH, UNLESS ACCESSORY & SEPARATE FROM MAIN PER RDS B.1.d.(1) VEHICULAR ACCESS VIA ALLEY OR PRIVATE STREET PER RDS C.1.c STREET FACING ENTRY DOOR NOT SET BACK MORE THAN 10 FT FROM PRINCIPAL FACADE PER RDS D.1.d.(1) ENTRY DOOR NO TALLER THAN 8FT PER RDS D.2.c ENTRY PORCH NOT MORE THAN ONE-STORY IN HEIGHT PER RDS D.3.c GROUP OF WINDOWS ON FRONT FACADE PER RDS E.1.d.(2) NO STREET-FACING WINDOWS MORE THAN ONE-STORY PER RDS E.2.c EXTERIOR MATERIALS CONSISTENT ON ALL SIDES & TRUE TO CHARACTERISTICS PER RDS E.5.c R-6 ZONE DISTRICT HEIGHT LIMIT 25' 60% + OF FRONT FACADE WITHIN REQ'D DISTANCE OF MINIMUM SETBACK PER RDS B.3.c LIGHTWELL PER RDS E.4.c & IRC R310.1 FRONT PORCH PER PER 26.575.020.D.5 VERTICAL CIRCULATION NOT COUNTED ON UPPER MOST FLOOR PER 26.575.020.D.2.a PATIO AT OR WITHIN 6" OF FINISHED GRADE PER 26.575.020.D.6 ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.j PROPOSED DRIVEWAY WITHIN 30" OF FINISHED GRADE PER 26.575.020.E.5.q TOP MOST PORTION OF ROOF PER 26.575.020.F.2 CHIMNEY PROTECTION <10' FROM HEIGHT OFBUILDING CONNECTION PER 26.575.020.F.4.a SAFETY GLAZING RADON VENT PIPE EXISTING HORIZONTAL WOOD SIDING TO BE REPAINTED VERTICAL METAL SIDING TBD STANDING SEAM ROOF SYNTHETIC SHINGLE EMERGENCY ESCAPE AND RESCUE DOORS PER IRC R310.3 DWELLING-GARAGE FIRE SEPARATIONPER IRC R302.6 BARS, GRILLS, COVERS, SCREENS OVER EMERGENCY ESCAPES AND RESCUE OPENING PER RDS 310.4 LINE OF EXTERIOR WALL BELOW DRIVEWAY TO REMAIN EXTERIOR DECK MATERIAL TBD HANDRAIL PER IRC 311.7.8 & 311.7.8.1 MIN HEIGHT 34" AC UNITS GUTTER SNOW STOPS / SNOW FENCE PANEL TO BE NON-LOCKING FLIP-UP GRATE & REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION DOWNSPOUT PROPOSED GRADE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE LIGHTWELL MINIMUM OPENING AREA PER IRC R310.2.1SNOWMELT PER IRC 310 LIFE & SAFETY DWELLING-GARAGE OPENING ANDPENETRATION PROTECTION PER IRC R302.5 GAS + ELECTRIC METERS ROOF OVERHANG GLASS GUARD SAFETY GLAZED PER IRC 308.4 &SUPPORT POINT LOAD PER IRC 301.5 DRYER FLUE VENT; TYP LINE OF FOUNDATION BELOW FALL PROTECTION PROVIDED PER R612.2 1/4" PER 1' SLOPE GAS LANTERNS BEVOLO CONTEMPORARY SERIES ASPHAULT SHINGLES TO BE REPLACED BRICK TO MATCH PAVER TBD LINE OF PROPOSED GRADE 2" CURB TYP. HOSE BIB LADDER AND STEPS PER IRC R310.2.3.1 1/2 POINT FROM EAVE TO RIDGE 1/3 POINT FROM EAVE TO RIDGE DRAWING ISSUANCE INDEX ID 01 02 03 NAME SCHEMATIC APPROVAL DD RDS REVIEW ISSUED DATE 10/2/17, 11:34 AM 10/2/17, 11:35 AM 10/2/17, 12:02 PM COPYRIGHT 10/2/17 KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION Z-202 HEIGHTS 10/2/17 RJL/JM/IS 1712.00 Aspen CO 81611 614 W NORTH ST Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Basalt: 104 Midland Ave, #202 Basalt, CO 81612 forumphi.com p: 970.279.4157 f: 866.770.5585 273512112006 7/10/17, 5:00 PM 9/1/17, 10:00 AM 2/27/2018 1 2 3 4 5 6 9'- 0 " 8' - 6 " 1'- 0 " 12 ' - 7 9/3 2 " 2'- 7 9/1 6 " 109110113114 212 10 13 26 9 18 111112 56 29 58 60 61 211 61 28 EXISTING MAIN LEVELT.O. PLY 100'-0" = 7891'-9" EXISTING UPPER LEVEL T.O. PLY 109'-6" T.O. EXISTING RIDGE 124'-8 1/2" EXISTING LOWER LEVEL T.O. CONC. 91'-0" T.O. EXISTING RIDGE 127'-0" EXISTING UPPER LEVEL STEP T.O. PLY 108'-6" 15 ' - 2 7/ 8 " 2' - 3 3/ 8 " PR O P E R T Y L I N E SE T B A C K L I N E PR O P E R T Y L I N E SE T B A C K L I N E SG SG SG SG SG SG SG T.O. EXISTING RIDGE122'-1 9/32" 1.) EXISTING FRAMING & SHEATHING TO REMAIN AT AREAS NOT SHOWN AS DEMOLISHED. TYPICAL. 2.) ALL DIMENSIONS TO EXISTING WALLS TO BE VERIFIED IN FIELD. TYPICAL. 3.) EXISTING RIDGE HEIGHTS TO REMAIN. 4.) ALL EXTERIOR MATERIALS TO REMAIN AND TO BE RE-FINISHED UNLESS NOTED OTHERWISE. 5.) ALL EXISTING WINDOWS AND EXTERIOR DOORS TO BE REPLACED. VERIFY IN FILED PRIOR TO ALL SHOP DRAWING APPROVALS. 6.) VERIFY ALL EXISTING & PROPOSED SPOT ELEVATIONS IN FIELD. PROJECT 100'-0" IS IN RELATION TO EXISTING TOP OF PLYWOOD ON THE MAIN LEVEL. GENERAL PLAN NOTES EXISTING TO REMAIN TO BE DEMOLISHED NEW WALL WALL LEGEND 0 2'4'8'SCALE: 1/4" = 1'-0"4 PROPOSED EAST ELEVATION STEVEN WILSON 402127 STA T E OF COLO R A D O L I C E NSED AR C H ITECT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t BUILDING NO GREATER THAN 50FT IN DEPTH, UNLESS ACCESSORY & SEPARATE FROM MAIN PER RDS B.1.d.(1) VEHICULAR ACCESS VIA ALLEY OR PRIVATE STREET PER RDS C.1.c STREET FACING ENTRY DOOR NOT SET BACK MORE THAN 10 FT FROM PRINCIPAL FACADE PER RDS D.1.d.(1) ENTRY DOOR NO TALLER THAN 8FT PER RDS D.2.c ENTRY PORCH NOT MORE THAN ONE-STORY IN HEIGHT PER RDS D.3.c GROUP OF WINDOWS ON FRONT FACADE PER RDS E.1.d.(2) NO STREET-FACING WINDOWS MORE THAN ONE-STORY PER RDS E.2.c EXTERIOR MATERIALS CONSISTENT ON ALL SIDES & TRUE TO CHARACTERISTICS PER RDS E.5.c R-6 ZONE DISTRICT HEIGHT LIMIT 25' 60% + OF FRONT FACADE WITHIN REQ'D DISTANCE OF MINIMUM SETBACK PER RDS B.3.c LIGHTWELL PER RDS E.4.c & IRC R310.1 FRONT PORCH PER PER 26.575.020.D.5 VERTICAL CIRCULATION NOT COUNTED ON UPPER MOST FLOOR PER 26.575.020.D.2.a PATIO AT OR WITHIN 6" OF FINISHED GRADE PER 26.575.020.D.6 ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.j PROPOSED DRIVEWAY WITHIN 30" OF FINISHED GRADE PER 26.575.020.E.5.q TOP MOST PORTION OF ROOF PER 26.575.020.F.2 CHIMNEY PROTECTION <10' FROM HEIGHT OFBUILDING CONNECTION PER 26.575.020.F.4.a SAFETY GLAZING RADON VENT PIPE EXISTING HORIZONTAL WOOD SIDING TO BE REPAINTED VERTICAL METAL SIDING TBD STANDING SEAM ROOF SYNTHETIC SHINGLE EMERGENCY ESCAPE AND RESCUE DOORS PER IRC R310.3 DWELLING-GARAGE FIRE SEPARATIONPER IRC R302.6 BARS, GRILLS, COVERS, SCREENS OVER EMERGENCY ESCAPES AND RESCUE OPENING PER RDS 310.4 LINE OF EXTERIOR WALL BELOW DRIVEWAY TO REMAIN EXTERIOR DECK MATERIAL TBD HANDRAIL PER IRC 311.7.8 & 311.7.8.1 MIN HEIGHT 34" AC UNITS GUTTER SNOW STOPS / SNOW FENCE PANEL TO BE NON-LOCKING FLIP-UP GRATE & REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION DOWNSPOUT PROPOSED GRADE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE LIGHTWELL MINIMUM OPENING AREA PER IRC R310.2.1SNOWMELT PER IRC 310 LIFE & SAFETY DWELLING-GARAGE OPENING ANDPENETRATION PROTECTION PER IRC R302.5 GAS + ELECTRIC METERS ROOF OVERHANG GLASS GUARD SAFETY GLAZED PER IRC 308.4 &SUPPORT POINT LOAD PER IRC 301.5 DRYER FLUE VENT; TYP LINE OF FOUNDATION BELOW FALL PROTECTION PROVIDED PER R612.2 1/4" PER 1' SLOPE GAS LANTERNS BEVOLO CONTEMPORARY SERIES ASPHAULT SHINGLES TO BE REPLACED BRICK TO MATCH PAVER TBD LINE OF PROPOSED GRADE 2" CURB TYP. HOSE BIB LADDER AND STEPS PER IRC R310.2.3.1 1/2 POINT FROM EAVE TO RIDGE 1/3 POINT FROM EAVE TO RIDGE DRAWING ISSUANCE INDEX ID 01 02 03 NAME SCHEMATIC APPROVAL DD RDS REVIEW ISSUED DATE 10/2/17, 11:34 AM 10/2/17, 11:35 AM 10/2/17, 12:02 PM COPYRIGHT 10/2/17 KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION Z-203 HEIGHTS 10/2/17 RJL/JM/IS 1712.00 Aspen CO 81611 614 W NORTH ST Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Basalt: 104 Midland Ave, #202 Basalt, CO 81612 forumphi.com p: 970.279.4157 f: 866.770.5585 273512112006 7/10/17, 5:00 PM 9/1/17, 10:00 AM 2/27/2018