Loading...
HomeMy WebLinkAboutFile Documents.1411 Crystal Lake Rd.0062.2018 (36).ARBKN IR1.0 job - 0154 drawn - TB SM A L L W O O D R E S I D E N C E AS P E N , C O L O R A D O IRRIGATION SCHEDULE piñon sage landscape architects 700 redstone ave carbondale, CO, 81623 devin@pinonsage.com (970) 379.0816 BUILDING PERMIT revisions - description- date 14 1 1 C R Y S T A L L A K E R O A D IRRIGATION SCHEDULE SYMBOL MANUFACTURER MODEL NO.DESCRIPTION DETAIL NO. HUNTER PROS-06-CV-PRS30 WITH MATCHED PRECIPITATION RATE SERIES NOZZLE POPUP SPRAY HEAD 1 HUNTER PROS-12-PRS40CV WITH MP-ROTATOR SERIES NOZZLE HI-POP SPRAY HEAD 2 RAIN BIRD PEB SERIES ELECTRIC CONTROL VALVE 3 SPEARS PVC BALL VALVE 9 RAIN BIRD ESP-LXME/F - 24 STATIONS ELECTRIC CONTROLLER 14 RAIN BIRD WR2-RFC (WIRELESS)WEATHER SENSOR DEVICE 15 RAIN BIRD 44 RC QUICK COUPLER 5 FEBCO 860U W PRV PVB BACKFLOW PREVENTER 16 RAIN BIRD PEB (1")MASTER CONTROL VALVE 7 RAIN BIRD FS100P (1")FLOW SENSOR 8 SCH 40 BE - 212" & SMALLER PVC MAINLINE 13 #100 NSF POLY LATERAL 13 CLASS 200 PVC SLEEVING 13 TORO BLUE STRIPE POLY DRIP TUBING -34" MIN. WIDTH 12 RAIN BIRD XCZ-100-COM-B DRIP VALVE ASSEMBLY 10 DRIP LINE BLOW-OUT STUB 11 N/S RAIN BIRD XERI-BUG DRIP EMITTERS 12 MANUAL DRAIN VALVE A W FS GPM CONTROL VALVE SIZE CONTROLLER & STATION NO. A (controller)NUMBER OF SPARE WIRES - 2 CONTROL AND 1 SPARE WIRES TO WHICH CONTROLLER - SEE CONSTRUCTION NOTES3 1.DRAWINGS AND BASE INFORMATION - ALL BASE AND PLANTING INFORMATION HAVE BEEN PROVIDED BY PINON SAGE LANDSCAPE ARCHITECTS. THE CONTRACTOR IS RESPONSIBLE TO NOTIFY HYDROSYSTEMS*KDI OF ANY DISCREPANCIES BETWEEN THE UTILITY OR PLANTING PLANS AND THE IRRIGATION PLAN. IF CONTRACTOR FAILS TO NOTIFY HYDROSYSTEMS*KDI AND MAKES CHANGES TO THE IRRIGATION SYSTEM DESIGN, HE ASSUMES ALL COSTS AND LIABILITIES ASSOCIATED WITH THOSE FIELD CHANGES. REFER TO SPECIFICATIONS FOR ADDITIONAL PROJECT REQUIREMENTS. CONTACT IRRIGATION CONSULTANT FOR CURRENT SPECIFICATIONS IF NOT PROVIDED. 2.SYSTEM PRESSURE - HYDROSYSTEMS*KDI HAS CONTACTED THE LOCAL WATER DISTRICT THAT SERVES THIS SITE AND THEY HAVE BEEN TOLD THAT THE STATIC WATER PRESSURE IN THIS AREA SHOULD BE 90 PSI. THE CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY PRESSURE PRIOR TO COMMENCING ANY CONSTRUCTION AND NOTIFY HYDROSYSTEMS*KDI OF ANY VARIANCE FROM THE STATED PRESSURE IMMEDIATELY. WRITTEN DOCUMENTATION OF PRESSURE TEST AND RESULTS SHALL BE PROVIDED TO HYDROSYSTEMS*KDI AT CONSTRUCTION ONSET. IF CONTRACTOR FAILS TO FIELD VERIFY PRESSURE AND/OR NOTIFY HYDROSYSTEMS*KDI OR ANY VARIATIONS FROM THIS PRESSURE, THEN HE ASSUMES ALL CONSTRUCTION AND ENGINEERING COSTS ASSOCIATED WITH SYSTEM MODIFICATIONS REQUIRED TO ACCOMMODATE ACTUAL SITE PRESSURE. THIS SYSTEM HAS BEEN DESIGNED FOR A REQUIRED STATIC PRESSURE OF 80 PSI MINIMUM. 3.IRRIGATION SYSTEM OPERATION INTENT - THIS IRRIGATION SYSTEM HAS BEEN DESIGNED TO IRRIGATE THE ESTABLISHED LANDSCAPE WITHIN A THREE NIGHT PER WEEK, FOUR HOUR PER NIGHT WATERING WINDOW. ESTABLISHMENT WATERING WILL REQUIRE UP TO TWICE AS MUCH IRRIGATION FOR A FOUR TO SIX WEEK PERIOD. THE DESIGN IS BASED ON THE FOLLOWING PROJECTED WEEKLY APPLICATION RATES AFTER ESTABLISHMENT. THESE FIGURES ARE BASED ON A 30-YEAR AVERAGE WEATHER DATA AND WILL NEED TO BE ADJUSTED DUE TO SEASONAL CHANGES AND WEATHER CONDITIONS ABOVE AND BELOW THE AVERAGE VALUES UTILIZED. NOTE: IT IS THE INTENT OF THIS DESIGN THAT NATIVE AREAS WOULD ONLY BE IRRIGATED FOR ESTABLISHMENT. SYSTEM WILL REMAIN FOR USE DURING YEARS WITH LESS THAN NORMAL RAINFALL. 4.EQUIPMENT INSTALLATION - IT IS THE INTENT OF THIS DESIGN THAT ALL IRRIGATION EQUIPMENT BE INSTALLED WITHIN PROPERTY LIMITS AND WITHIN LANDSCAPED AREAS. ANY EQUIPMENT OTHER THAN VALVE BOXES OR SLEEVING THAT CONTAINS PIPE OR WIRES SHOWN OUTSIDE OF THESE LIMITS IS SHOWN IN THAT LOCATION FOR GRAPHICAL CLARITY ONLY. ALL VALVE BOXES SHALL BE INSTALLED A MINIMUM OF 2'-0" FROM EDGE OF ANY PAVED SURFACES UNLESS SPECIFICALLY INDICATED ON PLANS. BOXES INSTALLED IN OPEN TURF AREAS SHALL BE KEPT TO EDGES AND STAKED FOR REVIEW IF ALONG HIGH TRAFFIC AREAS. ALL VALVE BOXES SHALL BE PLACED A MINIMUM OF 3'-0" FROM THE CENTERLINE OF ANY DRAINAGE SWALE. ALL VALVE BOXES WITHIN PAVEMENT SHALL BE TIER 15 RATED BOXES FOR HEAVY DUTY NON-DELIBERATE TRAFFIC. BOX LID COLOR SHALL MATCH ADJACENT MATERIALS, I.E. GREEN IN TURF, TAN IN WOOD MULCH, GRAY IN STONE MULCH, PURPLE FOR RECLAIMED WATER SYSTEMS (IF REQUIRED). REFER TO LANDSCAPE PLANS FOR MATERIAL COLORS AND TYPES. ALL BOXES SHALL BE INSTALLED TO BE FLUSH WITH GRADE AND IN AN ORDERLY MANNER. 5.MANUAL DRAIN VALVES - CONTRACTOR TO INSTALL ONE MANUAL DRAIN VALVE ON PRESSURE SUPPLY LINE DIRECTLY DOWNSTREAM OF BACKFLOW PREVENTER AND AT ALL LOW POINTS AND DEAD ENDS OF PRESSURE SUPPLY PIPING TO ENSURE COMPLETE DRAINAGE OF SYSTEM. CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THESE LOCATIONS IN-FIELD AND INSTALLATION LOCATIONS SHALL BE NOTED ON AS-BUILTS. 6.POP-UP SPRAY NOZZLES - CONTRACTOR TO INSTALL PLASTIC NOZZLES ON ALL POP-UP SPRAY HEADS. INSTALL 15 SERIES NOZZLES ON ALL HEADS SPACED AT 12' TO 14'. INSTALL 12 SERIES NOZZLES ON ALL HEADS SPACED 10' TO 11'. INSTALL 10 SERIES NOZZLES ON ALL HEADS SPACED AT 8' TO 9'. INSTALL 8 SERIES NOZZLES ON ALL HEADS SPACED AT 6' TO 7'. INSTALL 5' NOZZLES ON ALL HEADS SPACED AT 5'. INSTALL SIDE STRIP NOZZLES ON ALL HEADS WITH AN "S" DESIGNATION AND RIGHT AND LEFT CORNER STRIP NOZZLES ON ALL HEADS WITH AN "L" OR "R" DESIGNATION. VARIABLE ARC NOZZLES SHOULD BE UTILIZED ADJACENT TO CURVILINEAR SHRUB BEDS OR FOR ANY ANGLES THAT ARE NOT A STANDARD NOZZLE ANGLE. WHERE INDICATED, INSTALL LOW FLOW SQ SERIES SQUARE NOZZLES AT SPACING SHOWN. 7.DRIP IRRIGATION - REFER TO IRRIGATION DETAIL SHEET FOR DRIP EMITTER QUANTITIES AND PLACEMENT. 8.UNLABELED PIPING - ALL UNLABELED LATERAL PIPING SHALL BE 1" MINIMUM UNLESS OTHERWISE NOTED. 9.SLEEVING - ALL SLEEVING UNDER PAVED SURFACES SHOWN ON PLANS IS BY CONTRACTOR UNLESS OTHERWISE NOTED. SLEEVING SHALL BE INSTALLED IN THE SIZES AND QUANTITIES SHOWN ON PLANS OR BASED ON THE SCHEDULE BELOW. WHERE SLEEVES ARE SHOWN, BUT NOT LABELED, FOLLOW THE SCHEDULE BELOW. ALL MAINLINE, CONTROL WIRES AND DRIP LINES UNDER PAVED SURFACES ARE TO BE INSTALLED IN SLEEVING. ALL MAINLINE SLEEVE LOCATIONS TO INCLUDE A SEPARATE WIRE SLEEVE. SLEEVED PIPE SIZE/WIRE QUANTITY REQUIRED SLEEVE SIZE & (QUANTITY) 3 4" - 114" PIPING 2" PVC (1) 112" - 2" PIPING 4" PVC (1) 10.SPARE CONTROL WIRES - CONTRACTOR SHALL EXTEND THREE SPARE WIRES (ONE COMMON AND 2 CONTROL WIRES) FROM EACH CONTROLLER TO THE END OF THE MAINLINE SERVING THAT CONTROLLER OR AS SHOWN ON THE PLANS. INSTALL SPARE WIRES IN 10" ROUND VALVE BOX WITH QUICK COUPLING VALVE. REFER TO SPECIFICATIONS FOR WIRE COLOR. SEE IRRIGATION SCHEDULE FOR ADDITIONAL INFORMATION. 11.ADJUSTMENT - CONTRACTOR SHALL FINE TUNE/ADJUST THE IRRIGATION SYSTEM TO REDUCE/AVOID OVERSPRAY ONTO HARD SURFACES & ARCHITECTURE BY ADJUSTING NOZZLE DIRECTION AND NOZZLE RADIUS. 12.PLANS AND SPECIFICATIONS - CONTRACTOR RESPONSIBLE TO ENSURE WORK CONFORMS TO PLANS AND SPECIFICATIONS. AT ONSET OF CONSTRUCTION, VERIFY PLANS ARE CURRENT. WHERE REQUIRED BY CITY, CONTRACTOR SHALL CONSTRUCT ONLY OFF CITY STAMPED PLANS. REVISIONS TO CITY STAMPED PLANS SHALL CONFORM TO CITY FIELD CHANGE PROCEDURES AND DOCUMENTATION. 13.ASPEN WATER EFFICIENT LANDSCAPING DESIGNER STATEMENT - I HAVE COMPLIED WITH THE CRITERIA OF THE WATER EFFICIENT LANDSCAPING STANDARDS AND APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE IRRIGATION DESIGN PLAN. 14.IRRIGATION WITHIN ROW - CONTRACTOR IS RESPONSIBLE TO ENSURE THAT ANY IRRIGATION WITHIN THE ROW AREA (BETWEEN STREET AND THE PROPERTY LINE) IS TO BE ON SEPARATE CONTROL VALVES THAN THOSE WITHIN THE PROPERTY LINE. IRRIGATION CONSTRUCTION NOTES REFER TO SHEET IR1.0 IRRIGATION NOTES & SCHEDULE IR1.1 IRRIGATION PLANS IR2.0 IRRIGATION DETAILS IR2.1 IRRIGATION DETAILS AND CHARTS R CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. Know what's below. Call before you dig. #2 #2 #2 #2 HydroSystems-KDI, Inc. 860 Tabor Street, Suite 200 Lakewood, Colorado 80401303-980-5327 303-980-5384 (fax) Irrigation ConsultingNOT FOR CONSTRUCTION - REVIEW ONLY 3/29/2018 Please sign and provide p[professional qualifications CRYSTAL L A K E ROADCRYSTAL L A K E ROAD 7985 7985 7986 7986 79 8 5 79 8 4 7987 7 9 8 6 7986 7985 7985 7986 7986 7985 7984 7983 7982 7 9 8 3 7 9 8 2 7 9 8 1 7 9 8 0 79 7 9 7 9 8 2 7 9 8 3 7 9 8 4 798 4 798 3 7982 7981 7980 7975 797 6 7977 79787979 797 5 797 5 79 7 5 797 5 797 6 79 7 7 79 7 8 79 7 9 79 8 0 798 1 798 2 798 3 798 4 798 5 798 6 79 8 3 798 4 79 8 5 79 8 2 7 9 8 4 7 9 8 4 7983 7982 7986 7985 798 5 FS 11 4'' 11 4'' 11 4'' 11 4'' 11 4'' 11 4'' 11 4'' 11 4'' 11 4'' 11 4'' (2)2'' (2)2'' (2)2'' (2)2'' 11 1'' A5 12 1'' A4 8 1'' A3 12 1'' A8 12 1'' A7 DR 1'' A6 DR 1'' A1 DR 1'' A10 DR 1'' A2 10 1'' A20 12 1'' A21 A #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 9 1'' A11 10 1'' A12 11 1'' A9 DR 1'' A13 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 #2 9 1'' A14 9 1'' A15 DR 1'' A16 DR 1'' A17 10 1'' A18 10 1'' A19 12 1'' A22 0'5'10'20' Scale: 1" = 10' N IR1.1 job - 0154 drawn - TB SM A L L W O O D R E S I D E N C E IRRIGATION PLAN piñon sage landscape architects 700 redstone ave carbondale, CO, 81623 devin@pinonsage.com (970) 379.0816 revisions - description- date AS P E N , C O L O R A D O BUILDING PERMIT issue date - 3/2/18 14 1 1 C R Y S T A L L A K E R O A D R CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. Know what's below. Call before you dig. POINT OF CONNECTION #1 - 1" PEAK FLOW REQUIREMENT: 12 GPM. REQUIRED STATIC PRESSURE: 80 PSI MIN. CONTRACTOR SHALL COORDINATE INSTALLATION OF 1'' FEBCO 860U REDUCED PRESSURE BACKFLOW PREVENTER IN MECHANICAL ROOM, DOWNSTREAM OF WATER METER AND UP STREAM OF ANY PRESSURE REDUCING DEVICES. INSTALL ONE 1'' WATTS PRESSURE REDUCING VALVE AND EXTEND 1'' TYPE K COPPER TO 18'' BELOW GRADE AT POINT OF CONNECTION LOCATION. TIE ONTO COPPER DOWNSTREAM OF STUB FROM MECHANICAL ROOM WITH SCH 40 PVC AND INSTALL ONE FLOW SENSOR, ONE MASTER VALVE AND ONE BALL VALVE. EXTEND PVC MAINLINE AS SHOWN. EXTEND ONE PE89 SHIELDED CABLE FROM FLOW SENSOR TO DATA RETRIEVAL UNIT LOCATED IN ASSOCIATED CONTROLLER. EXTEND 4 UFUL14# WIRE (TWO ORANGE AND TWO BLUE) AND CONNECT 2 OF THE WIRES FROM THE MASTER VALVE TO THE DATA RETRIEVAL BOARD IN ASSOCIATED CONTROLLER. SEE DETAIL SHEET FOR REQUIRED PIPE LENGTHS UPSTREAM AND DOWNSTREAM OF FLOW SENSING UNIT. WORK SHALL CONFORM TO LOCAL CODE. FEES AND PERMITS ASSOCIATED WITH WORK ARE TO BE OBTAINED AND PAID FOR BY CONTRACTOR. FINAL BACKFLOW PREVENTER LOCATION SHALL BE APPROVED BY OWNER PRIOR TO INSTALLATION. CONTROLLER LOCATION "A" WALL MOUNT ONE CONTROLLER (REFER TO SCHEDULE FOR MODEL & STATION COUNT), AT INDICATED LOCATION. 120 VOLT POWER IS AVAILABLE WITHIN 40 LF. OF CONTROLLER LOCATION FROM RESIDENTIAL POWER. POWER CONNECTION TO CONTROLLER IS BY CONTRACTOR WITH WORK CONFORMING TO LOCAL CODES. EXTEND PE89 SHIELDED CABLE FROM THE FLOW SENSOR AND 4 #14 UFUL WIRES (TWO BLUE AND TWO ORANGE) FROM MASTER VALVE TO ASSOCIATED CONTROLLER. CONNECT WIRES TO THE APPROPRIATE SENSOR INPUT PORTS. FINAL CONTROLLER LOCATION SHALL BE APPROVED BY OWNER PRIOR TO INSTALLATION. MOUNT ONE WEATHER SENSOR ON FENCE WHERE THERE IS 20 FT. OF CLEARANCE FROM ANY OVERHANG OR OBSTRUCTING FEATURE. FINAL WEATHER SENSOR LOCATION SHALL BE APPROVED BY OWNER PRIOR TO INSTALLATION. HydroSystems-KDI, Inc. 860 Tabor Street, Suite 200 Lakewood, Colorado 80401303-980-5327303-980-5384 (fax) Irrigation Consulting REFER TO SHEET IR1.0 IRRIGATION NOTES & SCHEDULE IR1.1 IRRIGATION PLANS IR2.0 IRRIGATION DETAILS IR2.1 IRRIGATION CHARTS NOT FOR CONSTRUCTION - REVIEW ONLY 3/29/2018 Provide information that shows compliance with WELS Section 6.2.4 regarding irrigation on slopes greater that 25% Provide a hydrozone plan that complies with WELS Section 5.5.1, 5.5.2- Landscape Plan, 6.1.12, 6.1.13-Irrigation System Requirements, and 6.2- Hydrozone Requirements. (also noted on landscape plan) REFER TO SHEET IR1.0 IRRIGATION NOTES & SCHEDULE IR1.1 IRRIGATION PLANS IR2.0 IRRIGATION DETAILS IR2.1 IRRIGATION DETAILS AND CHARTS N IR2.0 job - 0154 drawn -TB SM A L L W O O D R E S I D E N C E AS P E N , C O L O R A D O IRRIGATION DETAILS piñon sage landscape architects 700 redstone ave carbondale, CO, 81623 devin@pinonsage.com (970) 379.0816 BUILDING PERMIT revisions - description- date issue date - 3/2/18 14 1 1 C R Y S T A L L A K E R O A D FINISH GRADE RECTANGULAR VALVE BOX WITH EXTENSION - BRAND "MV" INTO VALVE BOX LID. REFER TO TECHNICAL SPECIFICATIONS. SLIPxMIPT SCH. 40 PVC ADAPTER (2) PRESSURE MAINLINE 34" CRUSHED GRAVEL SUMP - 2 C.F. ELECTRIC MASTER CONTROL VALVE MASTER VALVE 724V - Small - Typical NO FITTINGS INCLUDING REDUCER BUSHINGS, TEES, ELLS, ETC, SHALL BE INSTALLED WITHIN "METER RUN" DISTANCE. DIAMETER OF FLOW SENSOR TEE AND "METER RUN" PIPING SHALL BE EQUAL. NO REDUCER BUSHINGS, ADAPTERS, ETC. SHALL BE INSTALLED WITHIN FLOW SENSOR TEE. DATA CABLE SPLICE CONSISTING OF WIRE NUTS AND PREFORMED SUPER SERVISEAL SPLICE KIT. FINISH GRADE RECTANGULAR VALVE BOX WITH EXTENSIONS AS REQUIRED. BRAND "FS" INTO VALVE BOX LID. REFER TO TECHNICAL TO TECHNICAL SPECIFICATIONS SPECIFICATIONS. VALVE BOX SHALL NOT REST DIRECTLY ON FLOW SENSOR CABLE. TEE STYLE FLOW SENSOR. REFER TO PLAN & SCHEDULE FOR SIZING, MANUFACTURER, & MODEL. DATA CABLE TO CONTROLLER SENSOR INPUTS PER MANUFACTURER RECOMMENDATION. PROVIDE ADDITIONAL CABLE WITHIN BOX TO ALLOW REMOVAL OF SENSING UNIT FROM BOX FOR MAINTENANCE PURPOSES. 3/4" GRAVEL SUMP - 2 CU. FT. PVC PRESSURE MAINLINE - REFER TO PLAN FOR DIAMETER. FLOW 10x PIPE DIA.5x PIPE DIA. METER RUN FLOW SENSOR 8VIA DATA CABLE - TEE STYLE 3" SET BOTTOM OF CAP AT GRADE CURB & GUTTER, SIDEWALK OR HARD SURFACE WHERE APPLICABLE POP-UP SPRAY HEAD 12" MALExBARB ELL 12" DIA. POLYETHYLENE SWING PIPE (4 L.F. MAXIMUM LENGTH) 12" MALExBARB ADAPTER POLY LATERAL PIPING W/ LINE SIZEx\" INSERTxFIPT FITTING AND CLAMPS POP-UP SPRAY HEAD NOTE: ·SET HEAD PERPENDICULAR TO FINISH GRADE. ·APPLY TEFLON TAPE TO MALE PVC THREADED FITTINGS. ·DOUBLE CLAMP 112" & 2" DIAMETER FITTINGS. 1 NOTE: DIAMETERS OF BALL VALVES, PVC FITTINGS AND NIPPLES SHALL EQUAL ELECTRIC CONTROL VALVE DIAMETER. VALVE BOXES SHALL BE INSTALLED PARALLEL OR PERPENDICULAR TO ADJACENT SIDEWALKS AND HARD SURFACES WHERE APPLICABLE. APPLY TEFLON TAPE TO ALL MALE THREADED FITTINGS AND THREADED NIPPLES. RECTANGULAR VALVE BOX. BRAND LID WITH CONTROLLER & STATION #. REFER TO TECHNICAL SPECIFICATIONS. CENTER BOX OVER ASSEMBLY. PROVIDE 12" CONTINUOUS COILS OF ALL "MAINTENANCE" SPARE CONTROL/COMMON WIRING WITHIN VALVE BOX PVC BALL VALVE - FIPTxFIPT 34" CRUSHED GRAVEL SUMP - FILL BOX TO BOTTOM OF VALVE BODY SCH. 80 PVC NIPPLE - LENGTH AS REQUIRED SERVICE TEE - SOLVENT WELD OR GASKETED FITTING - REFER TO SPECIFICATIONS CONTROL WIRE BUNDLE POLY LATERAL - SWEEP TO SPECIFIED DEPTH STAINLESS STEEL CLAMP - INSTALL TWO CLAMPS ON 112" & 2" DIA. FITTINGS PVC MIPTxINSERT ADAPTER ELECTRIC CONTROL VALVE 4" FINISH GRADE 3ELECTRIC CONTROL VALVE 24V - Poly Lateral FINISH GRADE 2" 3" 10" ROUND VALVE BOX. BRAND "GV" ON LID OF VALVE BOX. REFER TO TECHNICAL SPECIFICATIONS. GATE VALVE W/ CROSS HANDLE AND SOLID WEDGE DISC. 34" CRUSHED GRAVEL SUMP - FILL BOX TO WITHIN 2" OF TOP OF 6" PVC ACCESS SLEEVE∅ 6" CLASS 160 PVC SLEEVE BOTTOM TO BE NOTCHED AND CONTACT TOP OF PRESSURE MAINLINE PVC PRESSURE MAINLINE SCH. 40 PVC MALE ADAPTER (2) - SIZE TO EQUAL GATE VALVE DIAMETER UNDISTURBED SOIL GATE VALVE 6 3" 2" 10" ROUND VALVE BOX BRAND "QC" INTO VALVE BOX LID. REFER TO TECHNICAL SPECIFICATIONS. 34" CRUSHED GRAVEL SUMP - FILL BOX TO WITHIN 2" OF BOTTOM OF QCV LID 1" BRASS NIPPLE LENGTH AS REQUIRED LINE SIZE BRASS COUPLING 12"x12" REBAR STABILIZING STAKE TYPICAL TWO SIDES PER QUICK COUPLING VALVE LOCATION LASCO #G 13S-212 UNITIZED SWING JOINT W/ BRASS INSERT STABILIZER ELBOW. PROVIDE WITH 1" MIPT INLET PRESSURE MAINLINEx1" PVC SERVICE TEE - SOLVENT WELD OR GASKETED FITTING REFER TO SPECIFICAIONS QUICK COUPLING VALVE FINISH GRADE APPLY TEFLON TAPE TO ALL THREADED NIPPLES QUICK COUPLING VALVE 5 FINISH GRADE APPLY TEFLON TAPE TO ALL MALE THREADED PVC FITTINGS AND ALL NIPPLES 34" CRUSHED GRAVEL SUMP 1 CU. FT. 2" VALVE MARKER 10" ROUND VALVE BOX - BRAND THE LETTER "D' IN LID. REFER TO TECHNICAL SPECIFICATIONS. 2" CL 160 PVC ACCESS SLEEVE - LENGTH AS REQUIRED 34" FxF SCH. 80 PVC 90 ELL (2) 34"xCL PVC NIPPLE SCH. 80 (2) 34"x6" SCH. 80 GALVANIZED STEEL NIPPLE 34" BRASS GLOBE VALVE 34" MxF SCH. 40 PVC 90 ELL SOIL BLANKET COVERING SUMP 34"x4" PVC NIPPLE SCH. 80 34" CRUSHED GRAVEL SUMP. SEE TECHNICAL SPECIFICATIONS FOR SUMP SIZE PVC PRESSURE MAINLINE MANUAL DRAIN VALVE 4HI-POP SPRAY HEAD NOTE: ·SET HEAD PERPENDICULAR TO FINISH GRADE SWING. ·FLEX PIPE SHALL BE ATTACHED TO BOTTOM SPRAY HEAD INLET ONLY. ·APPLY TEFLON TAPE TO ALL MALE PVC THREADED FITTINGS AND NIPPLES. SET BOTTOM OF CAP AT GRADE 3" CURB AND GUTTER, SIDEWALK OR HARD SURFACE WHERE APPLICABLE 12" HI-POP SPRAY HEAD 12" MALExBARB 90d ELL 12" FLEX PIPE (6"-12" LENGTH) 12" MALExBARB ADAPTER POLY LATERAL PIPING W/ INSERTx12"FIPT FITTING 2 3" MIN. PVC SCH. 40 TEE OR ELL 3" MIN DEPTH OF 34" WASHED GRAVEL PVC MAINLINE PVC SCH. 80 NIPPLE, CLOSE PVC SCH. 80 UNION FOR SERVICING ASSEMBLY DRIP VALVE ASSEMBLY WITH BASKET FILTER (SEE SCHEDULE) FINISH GRADE JUMBO VALVE BOX - BRAND BOX LID W/ CONTROLLER AND STATION NUMBER - REFER TO TECHNICAL SPECIFICATIONS. WATER PROOF SPLICE 24" COILED WIRE PVC SCH. 80 NIPPLE PVC SCH. 40 ELL VALVE SIZE MIPTxINS. PVC ADAPTER STAINLESS STEEL WORM GEAR OR PINCH CLAMP VALVE SIZE POLY PIPING - SWEEP TO SPECIFIED DEPTH NOTE: INSTALL ASSEMBLY TO REST ON GRAVEL SUMP. CONTAIN ENTIRE ASSEMBLY WITHIN BOX. NO VALVE BOX EXTENSIONS WILL BE ACCEPTED. PROVIDE 3"-4" CLEARANCE BETWEEN TOP OF CONTROL VALVE SOLENOID AND BOTTOM OF VALVE BOX LID. TOP OF VALVE BOX TO BE FLUSH WITH FINISH GRADE. VALVE BOX SHALL NOT REST ON DRIP TUBING. DRIP VALVE 1024V - LARGE WITH POLY LATERAL FINISH GRADE DEFLECT TUBING TO PERMIT ENTRY THROUGH BOTTOM OF VALVE BOX. 12" POP-UP SPRAY HEAD WITH CHECK VALVE, CLOSED NOZZLE, & SWING PIPE (ZONE OPERATIONAL INDICATOR)PLANT MATERIAL 34" PVC BALL VALVE WITH 34" PVC INSxMIPT ADAPTER AND S.S. CLAMP 34" DRIP TUBING - COIL SUFFICIENT LENGTH IN BOX TO EXTEND HOSE ADAPTER OUTSIDE OF VALVE BOX. 34" WASHED RIVER ROCK SUMP (1 CU. FT.) INSERT TEE WITH CLAMPS 10" ROUND VALVE BOX WITH COVER - BRAND "DB" INTO VALVE BOX LID. REFER TO TECHNICAL SPECIFICATIONS. SECTIONPLAN DISTANCES VARY: CONTRACTOR SHALL LOCATE FLUSH VALVE BOX TO BE SCREENED BY PLANT MATERIAL AND ACCESSIBLE. OPERATIONAL INDICATOR SHALL BE LOCATED FOR EASY VISIBILITY DURING OPERATION PLANT MATERIAL INDICATOR HEAD PLANTER BED WALL OR EDGER FLUSH VALVE POLY PIPE FROM EXHAUST HEADER OR DRIP LATERAL DRIP FLUSH VALVE 11WITH OPERATIONAL INDICATOR PIPING SHUT-OFF VALVE FINISH GRADE 3"-4" SCH. 80 PVC BALL VALVE - SOCKETxSOCKET DIAMETER TO EQUAL PIPE DIAMETER 34" CRUSHED GRAVEL SUMP - 1 CU. FT. 6" CLASS 160 PVC SLEEVE. BOTTOM TO BE NOTCHED AND CONTACT TOP OF PRESSURE MAINLINE PVC PRESSURE MAINLINE OR LATERAL 10" ROUND VALVE BOX - BRAND "BV" ON LID OF VALVE BOX. REFER TO TECHNICAL SPECIFICATIONS. 9 R CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. Know what's below. Call before you dig. HydroSystems-KDI, Inc. 860 Tabor Street, Suite 200 Lakewood, Colorado 80401303-980-5327303-980-5384 (fax) Irrigation Consulting NOT FOR CONSTRUCTION - REVIEW ONLY 3/29/2018 0'5'10'20' Scale: 1" = 10' N IR 2.1 job - 0154 drawn - DG SM A L L W O O D R E S I D E N C E AS P E N , C O L O R A D O IRRIGATION DETAILS AND CHARTS piñon sage landscape architects 700 redstone ave carbondale, CO, 81623 devin@pinonsage.com (970) 379.0816 BUILDING PERMIT revisions - description- date issue date - 3/2/18 14 1 1 C R Y S T A L L A K E R O A D PLANT SIZE EMITTER FLOW RATE EMITTER QTY. AT MULCHED BED LOCATIONS EMITTER QTY. AT NATIVE SEED LOCATIONS 1 - 2 GALLON MATERIAL 0.5 GPH ONE EACH ONE EACH 5 GALLON MATERIAL 0.5 GPH TWO EACH TWO EACH 112" CALIPER TREE 1.0 GPH THREE EACH FOUR EACH 2" CALIPER TREE 1.0 GPH FOUR EACH SIX EACH 212" CALIPER TREE 1.0 GPH SIX EACH EIGHT EACH 3" CALIPER TREE 1.0 GPH EIGHT EACH TEN EACH 312" CALIPER TREE 1.0 GPH NINE EACH ELEVEN EACH 4" CALIPER TREE 1.0 GPH TEN EACH TWELVE EACH 6 FT. CONIFEROUS TREE 1.0 GPH FOUR EACH SIX EACH 8 FT. CONIFEROUS TREE 1.0 GPH SIX EACH NINE EACH 10 FT. CONIFEROUS TREE 1.0 GPH EIGHT EACH TWELVE EACH 12 FT. CONIFEROUS TREE 1.0 GPH TEN EACH FOURTEEN EACH NOTES: ·INSTALL EMITTERS ON OPPOSING SIDES OF ROOTBALL. THREE OR MORE EMITTERS SHALL BE EQUALLY SPACED AROUND ROOT BALL. ·EMITTERS ARE TO BE INSTALLED TO CLEAR SURFACE BY A MINIMUM OF 1" AND A MAXIMUM OF 2". ·FLUSH ALL LINES THOROUGHLY, INCLUDING EMITTER MICRO-TUBING PRIOR TO EMITTER INSTALLATION. ·IF PLANTING ON A 4:1 SLOPE OR STEEPER, INSTALL BOTH EMITTERS ON UPHILL SIDE OF ROOT BALL. ·EMITTERS SHALL BE SELF-FLUSHING, PRESSURE COMPENSATING-TYPE UNLESS NOTED OTHERWISE WITHIN TECHNICAL SPECIFICATIONS. ·DRIP VALVE ZONES ARE DESIGNED TO ACCOUNT FOR DIFFERENCES IN PLANT REQUIREMENTS (HYDROZONES) AND SUN EXPOSURE. ·CONTRACTOR SHALL ENSURE HYDROZONES ARE VALVED SEPARATELY AS SHOWN ON PLAN. ·SITE CONDITIONS MAY DICTATE THAT MULTIPLE SUN EXPOSURES ARE VALVED TOGETHER DURING THE DESIGN PROCESS. CONTRACTOR SHALL ADJUST EMITTER SCHEDULE AS FOLLOWS: ··EMITTER QUANTITIES SHALL REMAIN THE SAME BUT EMITTER GALLONAGES SHALL BE DOUBLED FOR PLANTS WITH SOUTH AND WEST EXPOSURES. ··EMITTER QUANTITIES AND GALLONAGE SHALL BE AS SHOWN IN SCHEDULE FOR PLANTS WITH NORTH AND EAST EXPOSURES. ··PLANTINGS WITH NORTH AND EAST EXPOSURE SHALL DICTATE VALVE RUN-TIMES AND CONTRACTOR SHALL ADJUST SCHEDULING ACCORDINGLY. DOWN 4:1(+)-SLOPE SECTION 10" MIN 4"-6" PLANTING BACKFILL MATERIAL POLY DRIP TUBING PLANT ROOTBALL EMITTER - STAKE TO EDGE OF ROOTBALL EMITTER MICRO-TUBING - 60" MAXIMUM LENGTH PLANT MATERIAL EMITTER - REFER TO SCHEDULE FOR EMITTER QUANTITY. REFER TO SPECIFICATIONS FOR MANUFACTURER AND MODEL NUMBER. MULCH LAYER EMITTER MICRO-TUBING POLY DRIP TUBING - RE: TECHNICAL SPECIFICATIONS 6" 10 GAUGE JUTE STAKE OR APPROVED EQUAL PLAN 12DRIP EMITTER BELOW GRADE 4-6" BODIES: 18" 12" BODIES: 24" CONTROL WIRE BUNDLE OR TWO WIRE COMMUNICATION CABLE (PER SPECIFICATIONS) 24" SPRAY HEAD LATERAL PIPING OR DRIP LINE HEADER. FINISH GRADE ROTOR LATERAL PIPING BACKFILL MATERIAL (TYP.) 4-6" BODIES: 14" 12" BODIES: 18" MAINLINE NOTE: REFER TO TECHNICAL SPECIFICATIONS FOR MINIMUM TRENCH WIDTHS. 1324"TYPICAL TRENCH REFER TO SHEET IR1.0 IRRIGATION NOTES & SCHEDULE IR1.1 IRRIGATION PLANS IR2.0 IRRIGATION DETAILS IR2.1 IRRIGATION DETAILS AND CHARTS R CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. Know what's below. Call before you dig. HydroSystems-KDI, Inc. 860 Tabor Street, Suite 200 Lakewood, Colorado 80401 303-980-5327303-980-5384 (fax) Irrigation Consulting TYPE "K" RIDGED COPPER - CONNECT TO BUILDING COLD WATER SERVICE LINE DOWNSTREAM OF WATER METER & UPSTREAM OF ANY PRESSURE REDUCING VALVES OR OTHER BUILDING SERVICE EQUIPMENT FEBCO 860U REDUCED PRESSURE BACKFLOW PREVENTER WITH INTEGRAL UNIONS CxM ADAPTER - LINE DIA. (FOUR REQ'D.) TYPE K RIGID COPPER TO SOFT AREA CxCxF TEE 34" I.P. MALE BRASS BOILER DRAIN W/ WHEEL HANDLE FEBCO 601 AIR GAP DRAIN 2" TYPE "L" RIGID COPPER TUBING FASTEN TUBING TO FINISH FLOOR @ 18" O.C. VENT BACKFLOW PREVENTER DRAIN TO FLOOR DRAIN SECURE BACKFLOW PREVENTER ASSEMBLY AND COPPER TUBING TO WALL VIA UNI-STRUT CHANNEL AND COPPER FASTENERS AT 6 FT. O.C. FLOW 12" MIN. PRESSURE REDUCING VALVE - WATTS #223-HP OR EQUAL - DIA. TO EQUAL BFP BACKFLOW PREVENTER 16INTERIOR LOCATION - WITH PRESSURE REDUCING VALVE ELECTRIC CONTROLLER PVC CONDUIT W/ SWEEP ELL (TYP. UNDERGROUND LOCATIONS) - 2 EACH LOCATION - ONE 2" PVC SCH 40 DIRECT BURIAL CONDUIT STUB-OUT FOR 24V VALVE CONTROL WIRING AND ONE 34" PVC CONDUIT FOR 120V POWER SUPPLY IN DIRECT BURIAL CONDUIT AS PER CITY CODE. FINISH GRADE EMT MALE ADAPTER & PVC FEMALE ADAPTER SECURE CONDUIT TO WALL 18" O.C. EMT CONDUIT - SIZE TO ACCOMMODATE CONTROL WIRE QUANTITY EMT MALE ADAPTER W/ WASHER & LOCK RING ELECTRIC CONTROLLER SECURE CONTROLLER TO WALL WITH ANCHOR BOLTS 18'' 54" MIN. 60" MAX. EXTERIOR WALL MOUNT 14 WIRELESS RAIN SENSOR (MODEL PER SCHEDULE) - TOP OF SENSOR TO BE ABOVE GUTTER AND/OR ANY OBSTRUCTIONS ADJUSTABLE LENGTH MOUNTING ARM SECURE BRACKET TO EAVE PER MANUFACTURER'S RECOMMENDATIONS. BUILDING EAVE NOTE: MOUNT SENSOR RECEIVER PER CONTROLLER DETAIL. WEATHER SENSOR 15EAVE MOUNTED - Wireless NOT FOR CONSTRUCTION - REVIEW ONLY 3/29/2018