HomeMy WebLinkAboutFile Documents.993 Moore Dr.0322.2017 (20).ARBKChannel Report
Hydraflow Express Extension for Autodesk® AutoCAD® Civil 3D® by Autodesk, Inc.Tuesday, Jul 3 2018
8-IN PVC @ 2%--80 Percent Full
Circular
Diameter (ft) = 0.67
Invert Elev (ft) = 100.00
Slope (%) = 2.00
N-Value = 0.011
Calculations
Compute by: Q vs Depth
No. Increments = 10
Highlighted
Depth (ft) = 0.54
Q (cfs) = 2.000
Area (sqft) = 0.30
Velocity (ft/s) = 6.61
Wetted Perim (ft) = 1.48
Crit Depth, Yc (ft) = 0.63
Top Width (ft) = 0.54
EGL (ft) = 1.22
0 1
Elev (ft)Section
99.75
100.00
100.25
100.50
100.75
101.00
Reach (ft)
Reviewed by Engineering
08/10/2018 1:46:49 PM
"It should be known that this review shall not
relieve the applicant of their responsibility to
comply with the requirements of the City of
Aspen. The review and approval by the City is
offered only to assist the applicant's
understanding of the applicable Engineering
requirements." The issuance of a permit based
on construction documents and other data shall
not prevent the City of Aspen from requiring the
correction of errors in the construction
documents and other data.