Loading...
HomeMy WebLinkAboutFile Documents.993 Moore Dr.0322.2017 (20).ARBKChannel Report Hydraflow Express Extension for Autodesk® AutoCAD® Civil 3D® by Autodesk, Inc.Tuesday, Jul 3 2018 8-IN PVC @ 2%--80 Percent Full Circular Diameter (ft) = 0.67 Invert Elev (ft) = 100.00 Slope (%) = 2.00 N-Value = 0.011 Calculations Compute by: Q vs Depth No. Increments = 10 Highlighted Depth (ft) = 0.54 Q (cfs) = 2.000 Area (sqft) = 0.30 Velocity (ft/s) = 6.61 Wetted Perim (ft) = 1.48 Crit Depth, Yc (ft) = 0.63 Top Width (ft) = 0.54 EGL (ft) = 1.22 0 1 Elev (ft)Section 99.75 100.00 100.25 100.50 100.75 101.00 Reach (ft) Reviewed by Engineering 08/10/2018 1:46:49 PM "It should be known that this review shall not relieve the applicant of their responsibility to comply with the requirements of the City of Aspen. The review and approval by the City is offered only to assist the applicant's understanding of the applicable Engineering requirements." The issuance of a permit based on construction documents and other data shall not prevent the City of Aspen from requiring the correction of errors in the construction documents and other data.