HomeMy WebLinkAboutFile Documents.533 W Hallam St.0031-2022-BCHO (11)SMOKE ALARMS AND
CARBON MONOXIDE
DETECTORS REQUIRED
THROUGHOUT DWELLING
UNIT PER CITY OF ASPEN
MUNICIPAL CODE 8.15
These plans must be kept at the
building site or inspection
delays may occur. Construction
shall conform to these plans. All
changes shall be approved by
the building official.
Field Plan Set Must Be Printed In Color
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING, MECHANICAL, OR
FIRE SPRINKLER WORK
SEE NOTES #1 PLANS
It should be known that this review shall
not relieve the applicant of their
responsibility to comply with the
requirements of the City of Aspen
Municipal Code. Pursuant to
Sec.26.104.050, any permit or approval
issued in error or otherwise not in
conformity with the requirements of this
Title, shall be void. Similarly, any permit
or approval issued in reliance upon or
as a result of, a materially false
statement or representation made in
the process of obtaining the permit or
development approval shall, likewise,
be void. Any person having received a
void or voidable permit or approval
shall not be relieved from having to
comply with all applicable terms and
conditions of this Title and the City shall
not be estopped from fully enforcing
same.
sophiev
08/25/2022ZONING
“A Written Narrative”
• The house was set 0.3' higher in space than what was originally permitted. The change in overall heights and grading can
be seen on-
(Architectural Sheets)
G012 ROOF HEIGHTS,
(Civil Sheets)
C4 Grading & Drainage Plan
• We have maintained the grade relationship to the historic house, and the new house. the grade raised as the house
raised in space. We also are now sloping the patio given that the entire system has changed. The impact of the patio to
grade elevations can be seen on
(Architectural Sheets)
A102a, SITE DETAILS, Clouded Details 3, 4, 5, and 6,
A102b SITE DETAILS, Clouded Details 1 and 2
A401 ELEVATIONS – NORTH, Clouded areas
A402 ELEVATIONS – WEST, Clouded areas
A403 ELECATIONS – SOUTH, Clouded areas
A404 ELEVATIONS – EAST, Clouded areas
A411a PATIO SECTIONS, Clouded Sections 2, 3, and 4
A812 DETAILS – EXTERIOR, Clouded Detail 5
(Civil Sheets)
C4 Grading & Drainage Plan – Clouded entire plan as all points against house changed.
Reference 10.Drainage-Report 533 W Hallam Change Order #2 03172022
• We have changed from a previous paver system to a solid sloped patio system. Also, the overall pattern changed slightly.
The paver changes can be seen on
(Architectural Sheets)
G011 RREMP PLAN, See the Clouded RREMP AREA calculations in the upper right corner, and the clouded area on the
left of the sheet by the garage and lightwell adjacent to the garage.
A101 ARCHITECTURAL SITE PLAN,
A102a SITE DETAILS, Clouded Details 3, 4, 5, and 6,
A102b SITE DETAILS, Clouded Details 1 and 2
A411a PATIO SECTIONS, Clouded Sections 2, 3, and 4
A801 ASSEMBLIES – FLOOR, Clouded Assemblies F-10 and F-11
A805 ASSEMBLIES – ROOF, Clouded Assembly R-1
A812 DETAILS – EXTERIOR, Clouded Details, 5, 6, 7, and 10
• The snow melt has expanded around where the garage skirt is located, and around the lightwell on the south east side of
the house.
(Architectural Sheets)
G011 RREMP PLAN – See the Clouded RREMP AREA calculations in the upper right corner, and the clouded area on
the left of the sheet by the garage and lightwell adjacent to the garage.
(Mechanical Sheets)
M-002 MECHANICAL SCHEMATICS & SEQUENCE – See clouded area.
M-120 CRAWLSPACE MECHANICAL PIPING PLAN – See clouded area.
M-121 LOWER LEVEL MECHANICAL PIPING PLAN – See clouded area.
M-122 FIRST FLOOR MECHANICAL PIPING PLAN – See clouded area
M-600 MECHANICAL SCHEDULES – See clouded areas.
Reference 10.533 W Hallam RREMP Calculations 03.17.2022
• We are not a part of the Moratorium.
Reference 10.533 W Hallam Moratorium Exemption Application 2021_032832022
Please let us know if something is not clear.
05/17/2022
As-built survey/height
will be verified as part
of the final inspection.
External Energy Use Approved
RREMP CREMP
PERMIT #:_______________DATE:________
SNOWMELT:_____________________________
POOL: _____________________________
SPA: _____________________________
OFFSET:________________________________
REMP SHEET: __________________________
REVIEWED BY: _________________________
SNOWMELT SYSTEM AND EQUIPMENT MANDATORY REQ’S.
All snowmelt systems shall meet the following:
-Any portions in the Right of Way must be on a separate zone. A ROW
permit and Permanent Encroachment License are required.
-R10 insulation shall be installed under the area to be snow melted or R5
insulation shall be installed under and at the slab edges. (Ordinance 11
Series 2011)
-Automatic controls installed for system shut off when pavement
temperature is above 50°F and no precipitation is falling. (2009 IECC
Sec. 403.8 & 503.2.4.5)
-Automatic or manual controls installed for system shut off when outdoor
temperature is above 40°F. (2009 IECC Sec. 403.8 & 503.2.4.5)
-Inspection by testing hydrostatically at 1½ times max system design
pressure, but not less than 100psi, for 15minutes. (2009 IMC Sec.
1208.1)
MINIMUM BOILER AFUE: _________________
X
0031-2022-BCHO
MASTER 0285.2018.ARBK 9/7/22
1236.75 SQ.FT. HYDRONIC
G010, G007
95%
128,000 BTU/HR GSHP SYSTEM
JH
APPLICATION ACCEPTED DATE: 2022-05-17 PERMIT NUMBER: 0031-2022-BCHO
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT COVERSHEET
PROPERTY INFORMATION
ADDRESS: 533 W HALLAM ST UNIT:
PARCEL ID: 273512432001 LEGAL DESCRIPTION: CITY AND TOWNSITE OF ASPEN
OWNER: DUNCAN SKIHAUS LLC
PERMIT CONTRACTOR:
DESCRIPTION OF WORK The house was set 0.3' higher in space than what was originally permitted. We have maintained the grade
relationship to the historic house, and the new house. the grade raised as the house raised in space. We have
changed from a pervious paver system to a solid patio system. The snow melt has expanded around where the
garage skirt is located, and around the lightwell on the south east side of the house. We have almost everything
together that was asked for in the pre -app email except for a Survey. The Surveyor cannot put one together
because the project is under construction and there is no way to shoot points in any way that would be useful to
any of us. The only thing they were able to do is to establish what the 100’ benchmark elevation of the house is
at now.
USE OF BUILDING Single Family FIRE SPRINKLER REQUIRED? Yes
CLASS OF WORK Residential FIRE SPRINKLER TYPE NFPA 13 D
BUILDING TYPE (IRC) One family REQUIRED SPECIAL
INSPECTIONS
CONSTRUCTION TYPE VB ENERGY CODE COMPLIANCE
OCCUPANCY GROUP (IBC) R -1 WORK CHANGES BUILDING
FOOTPRINT? No
CODE EDITIONS 2015 IRC TOTAL SPA SQ.FT.
OTHER CODE EDITIONS TOTAL SNOWMELT SQ.FT. 1,237
HISTORIC PROPERTY? Yes TOTAL POOL SQ.FT.
FIRE SPRINKLER EXISTING? Yes
09/08/2022
justinh
SEE NOTES #1 PLANS
0031-2022-BCHO Master: 0285.2
Duncan Skihaus LLC
533 W Hallam
273512432001
85.2018.ARBK
2
REVIEWED FOR
COMPLIANCE
10/06/2022 sarahy
BY HPC