HomeMy WebLinkAboutFile Documents.1112 Waters Ave.0024.2019 (30).ARBKDATE
Date:
Scale:
Drawn by:
REVISIONS
Z4A
WWW.ZONE4ARCHITECTS.COM
SD100%11.02.18
RDS Approval 12.10.18
Permit 02.15.19
Permit Rev. 1 04.05.19
Permit Rev. 2 06.18.20
C:\Us
e
r
s
\Br
e
n
d
a
n
Ha
m
l
e
t
\De
s
k
t
o
p
\Iz
e
n
\On
Se
r
v
e
r
\11
1
2
Wa
t
e
r
s
Pe
r
m
i
t
6.18
.19
RE
V
2.pl
n
A204
6/19/2020Plotted On:
6/19/2020
AS NOTED
PROPOSED
South and East
Elevations
ZO
N
E
4
AR
C
H
I
T
E
C
T
S
IS
NO
T
LI
A
B
L
E
OR
RE
S
P
O
N
S
I
B
L
E
AT
AN
Y
TIM
E
FO
R
AN
Y
CH
A
N
G
E
S
TO
TH
E
S
E
DR
A
W
I
N
G
S
OR
SP
E
C
I
F
I
C
A
T
I
O
N
S
WIT
H
O
U
T
PR
I
O
R
WR
I
T
T
E
N
AU
T
H
O
R
I
Z
A
T
I
O
N
.
c
20
1
8
ZO
N
E
4 AR
C
H
I
T
E
C
T
S
, LL
C
.
TH
E
IN
F
O
R
M
A
T
I
O
N
AN
D
DE
S
I
G
N
IN
T
E
N
T
CO
N
T
A
I
N
E
D
ON
TH
I
S
DO
C
U
M
E
N
T
IS
TH
E
PR
O
P
E
R
T
Y
OF
ZO
N
E
4 AR
C
H
I
T
E
C
T
S
LL
C
. NO
PA
R
T
OF
TH
I
S
IN
F
O
R
M
A
T
I
O
N
MA
Y
BE
US
E
D
OR
CO
P
I
E
D
WI
T
H
O
U
T
TH
E
PR
I
O
R
WR
I
T
T
E
N
PE
R
M
I
S
S
I
O
N
OF
ZO
N
E
4 AR
C
H
I
T
E
C
T
S
LL
C
.
ZO
N
E
4
AR
C
H
I
T
E
C
T
S
LL
C
.
SH
A
L
L
RE
T
A
I
N
AL
L
CO
M
M
O
N
LA
W
ST
A
T
U
T
O
R
Y
AN
D
AL
L
OT
H
E
R
RE
S
E
R
V
E
D
RIG
H
T
S
,
IN
C
L
U
D
I
N
G
CO
P
Y
R
I
G
H
T
TH
E
R
E
T
O
.
AL
L
RIG
H
T
S
RE
S
E
R
V
E
D
11
1
2
Wa
t
e
r
s
Av
e
11
1
2
Wa
t
e
r
s
Av
e
n
u
e
As
p
e
n
,
CO
81
6
1
1
Ci
t
y
of
As
p
e
n
,
Pi
t
k
i
n
Co
u
n
t
y
A B C
100'-1 1/2"(FF Main Level)
95'-10 3/4"(FF Lower Level)
104'-6 3/4"(FF Upper Level)
16
'
-
1
1
"
(f
o
r
Zo
n
i
n
g
on
l
y
)
shown beyond (to illustrate
most restrictive condition)
gutter w/ heat tape
shown beyond where roof rake
@ North Facade crosses
property boundary (to illustrate
most restrictive condition)
closed in between BO
porch roof and TO roof @
home
improved drainage away from
building TYP
metal to match window
frames
support for porch roof
beyond, RE: STRUCT.
range vent
chimney flue per code
metal to match window
frames
condensing unit within 30" of
proposed grade
25' grade offset (most restrictive)
A3A4
C5
C3C4
B15
B12
B13 B11 B10 B9
B8
BU
I
L
D
I
N
G
EN
V
E
L
O
P
E
PR
O
P
E
R
T
Y
BO
U
N
D
A
R
Y
102A
metal @ office to align w/ BO
window B13
2 1
95'-10 3/4"FF Lower Level
100'-1 9/16"FF Main Level
104'-6 13/16"FF Upper Level
2'
-
6
"
existing grade
improved drainage away
from building TYP.
condensing unit within 30"
of proposed grade
25' grade offset (most
restrictive)
B14
clear cedar siding
stuco
painted wood
SIDING LEGEND
metal standing seam roof
SCALE: 1/4" = 1'-0"1 PROPOSED South Elevation