Loading...
HomeMy WebLinkAboutFile Documents.809 S Aspen St.0219.2018 (10).ARBKEARTH ENERGY ENVIRONMENT (E3) Industrial Hygiene and Environmental Engineering August 31, 2018 Mr. Heath Wolfe Advantage Environmental Inc. Aurora, Colorado Subject: Clearance Report 809 S Aspen Street Aspen, CO 81611 Dear Mr. Wolfe: Following is the project completion report for the work area at 809 S Aspen Street in Aspen, CO 81611. The purpose of this report is to document this remediation project was successfully completed, and indoor asbestos amplification was not occurring in the work area. An Industrial Hygienist for Earth Energy Environment (E3) performed the remediation project completion inspection and testing procedures. The remediation work area (Interior Area) was visually inspected in order to confirm the scope of work was properly followed and completed. The containments were also visually inspected to verify breaches and/or defects were not present. Phase Contrast Microscopy (PCM) samples were collected in accordance with the National Institute for Occupational Safety and Health (NIOSH) method 7400 using cassettes (standard 3 piece, 25 mm dia., 0.8 um MCE filter) purchased from Zefon International, Inc. The asbestos concentrations in the containment were calculated as airborne fibers per cubic centimeter of air (F/cc). Table 1 provides a summary of the sample numbers, sample volumes, and calculated concentrations. The National Emission Standards for Hazardous Air Pollutants (NESHAP) clearance standard is 0.01 F/cc. Visual inspection confirmed that no asbestos-containing debris was observed in the work areas. The PCM clearance air sample results were all below the NESHAP clearance standard of 0.01 F/cc. Based on the information presented above, E3 concludes the asbestos abatement in the work area has been successfully completed, and the work area may be reoccupied after build back. 5366 Godding Hollow Pkwy Longmont, CO 80504 Local: 303.902-5851 11/07/2018 PCM Air Clearance Page 2 of 2 ______________________________________________________________________ TABLE 1: PCM CLEARANCE AIR SAMPLING RESULTS Date Unit/ Area Sample # Sample Description Sample Volume *Fibers/cc August 31, 2018 Air Clearance at: 809 S Aspen Street in Aspen, CO 81611 (Interior Area) CL-083118-1 CL-083118-2 CL-083118-3 CL-083118-4 CL-083118-5 BLK-1 BLK-2 Inside Containment Blanks 1005 990 980 975 965 - - 0.001 0.001 0.001 0.001 0.001 BRL BRL *BRL denotes “Below Reporting Limits”. The PCM Colorado Department of Public Health and Environment (CDPHE) clearance standard is 0.01 F/cc. Thank you for allowing E3 the opportunity to provide environmental services to you. If you have questions or require additional information, do not hesitate to contact me directly at (303) 902-5851. Sincerely, Eli Willden Certified Air Monitoring Specialist No. 20139 11/07/2018