Loading...
HomeMy WebLinkAboutFile Documents.219 E Durant Ave.0094.2018 (12).ACBKPierce + Frye Architects  Vail & San Francisco 970.949.0899 Almresi Aspen, 219 E. Durant Ave, Unit C5     RE:  Permit Number: 0094.2018.ACBK  Zoning Plan Review Comments    February 28, 2019  Attn: Sophie Varga, Zoning Enforcement Officer  City of Aspen, Community Development Department  Phone:  970/429‐2778, Fax:  970/920‐5440,     John Barker, Permit Coordinator, City of Aspen   Phone:  970‐429‐2019  John.Barker@CityofAspen.com     Dear Sophie,    Regarding your zoning plan review comments for the above reference building permit, received  10/5/18, please see the attached drawings, specifications and responses to plan review  comments.    Because of the issues raised in the plan reviews, the costs of the kitchen hood venting system  and logistics issues with the initial kitchen design choice, the design for the restaurant has been  modified in response to these concerns.  The lower level is now completely dedicated to storage  needs and employee support spaces and the kitchen has been moved to the street level.  The  airlock entry has been removed from the plans and the modification to the residence lobby has  been removed as well.    The drawings have been revised.  Each of the zoning plan review comments have been  addressed and resolved, or eliminated.  We have responded to each of the zoning plan review  comments and these are summarized.      Zoning Plan Review Comments received on October 5, 2018 (attached):  Building Comments:  1. All revisions to Floor Area and Net Leasable Area have been eliminated from the plans.  The air‐lock entry has been eliminated. Because the kitchen has been relocated to the  street level, the need for a dumbwaiter has been eliminated and the dumbwaiter has  been removed from the plans.  The expansion of the net leasable area into the  residence lobby has been eliminated.  The wall and door location will remain as platted. 03/17/2019 Pierce + Frye Architects  Vail & San Francisco 970.949.0899 2. The referenced area on the lower level is no longer included in the scope of work.  There  will be now work done in this area.  3. See response to comment #1 above. This area is no longer included in the design.  4. See response to comment #1 above. This area is no longer included in the design and  therefore the lobby will remain as is. This is no longer part of the scope of our building  permit application.  5. See response to comment #1 above. This area is no longer included in the design.  6. See response to comment #1 above. The dumb waiter is no longer included in the  design.    Mechanical Permit Comments:  1. In conjunction with the kitchen being relocated to the street level of the building, the  equipment specs have been revised to eliminate the vented hood system.  The new  kitchen design and specs include a ventless hood system.  The specified system will not  require additional outside air.  The roof top make up air unit has been removed from  the design.  There will be some general room exhaust that will make use of the vent  terminations that already exist on top of the elevator overrun shaft.  There will be no  new roof top equipment or vents added.  Because the building elevations are not  needed to verify rooftop equipment appearance or heights, they have been removed  from the drawings set. Please refer to revised mechanical plans.    Regarding the note at the end of the zoning plan review comments requesting a copy of the  HOA Compliance Policy, this document was submitted with the original building permit  application.  Please coordinate with John Becker to obtain a copy of this document.     Thank you for your prompt attention to these responses to your building plan review.  We  appreciate your efforts to process all of the information quickly.  Please don’t hesitate to call  with any questions.    Regards,    Tom Frye  Pierce + Frye Architects  970‐949‐0899 x2    Attachments:  Responses to building plan review comments.  Three, full size, stamped and signed sets of revised drawing sheets  One copy of lighting specifications/cutsheets  One copy of Food Service specifications/cutsheets  One copy of Interior Lighting and Mechanical Compliance Certificates (COMcheck)  03/17/2019