HomeMy WebLinkAboutFile Documents.219 E Durant Ave.0094.2018 (15).ACBK Welbilt, Inc. 2227 Welbilt Boulevard New Port Richey, FL 34655 USA T +1.727.375.7010 www.welbilt.com To Whom It May Concern: Kolpak and Harford walk-ins comply with regulatory requirements including National Sanitation Foundation (NSF7), Underwriters Laboratory (UL), International Building Code (IBC), Energy Independence and Security Act (EISA), International Energy Conservation Code (IECC), Department of Energy (DOE), California Code of Regulations Title 20, City of Houston, State of Oregon, and are accepted by the United States Department of Agriculture. Units requiring Factory Mutual (FM 4880), City of Los Angeles (LARR), and Miami Dade County are available. The foam plastic used in this product is CFC and HCFC free and complies with build code Chapter 26. The requirements of section 2603.4.1.2 are satisfied when used with an automatic sprinkler by others and will not require a thermal barrier. The requirements of section 2603.4.1.3 are satisfied without a sprinkler as long as no panel is over 4” thick, the aggregate walk-in floor area does not exceed 400 square feet, and a thermal barrier by others is present. The foam has been tested to ASTM E-84 as follows: flame spread rating: 20; smoke developed rating: 250-400; minimum flash-ignition temperature rating: 890°f; minimum spontaneous ignition temperature rating: 806°f. Also, the foam will have a covering of not less than 0.032-inch aluminum or corrosion- resistant steel having a base metal thickness not less than 0.0160 inch at any point. Energy code requires the following minimum R-values: R-25 for coolers, R-32 for freezers, and R-28 for freezer floors. Kolpak foam is tested in accordance with ASTM C518 and has the following results. For coolers (reported at 55 F mean temperature) 4” thick: R-29 5” thick: R-36 6” thick R-44 For freezers (reported at 20 F mean temperature) 4” thick: R-32 5” thick: R-40 6” thick: R-48 4” floor: R-29 The following further complies with energy code: • Doors will have closers designed to firmly close walk-in doors that have been closed to within 1 of full closure. • Doors will have strip doors, curtains, spring-hinged doors or other method of minimizing infiltration when doors are open. • Lights will have an efficacy of not less than 40 lumens per watt and be vapor tight. • Viewports will be triple-pane glass, either filled with inert gas or with heat-reflective treated glass. • Transparent reach-in doors without anti-sweat heater controls will have a heater power draw of no more than 7.1 or 3.0 watts per square foot of door opening for freezers and coolers, respectively. When supplied with anti-sweat heater controls, the heater power draw will either 03/17/2019 have a heater power draw of no more than 7.1 or 3.0 watts per square foot of door opening for freezers and coolers, respectively, or the anti-sweat heater controls will reduce the energy use of the heater in a quantity corresponding to the relative humidity of the air outside the door or to the condensation on the inner glass pane. • Evaporator fan motors that are less than 1 HP and less than 460 volts are electronically commutated motors. • Condenser fan motors that are less than 1 HP are permanent split-capacitor motors. • Calculations for section C403.2.14 are available from Refrigeration Engineering upon request. Attached are additional reference documents. Please let us know if you have any further concerns. Regards, Tony Moffett Senior Engineer, Kolpak T +1.731.847.5629 Welbilt 03/17/2019 The Public Health and Safety Organization NSF Product and Service Listings These NSF Official Listings are current as of Tuesday, April 10, 2018 at 12:15 a.m. Eastern Time. Please contact NSF International to confirm the status of any Listing, report errors, or make suggestions. Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/food/Listings.asp?Standard=007&Company=26700& NSF/ANSI 7 Commercial Refrigerators and Storage Freezers Kolpak 2915 North Tennessee Avenue Parsons, TN 38363 United States 731-847-5342 Visit this company's website (http://www.kolpak.com) Facility : # 1 Parsons, TN Air Shield[1] [2] [3] HALC2-N1(1) HARC2-N1(1) [1] Not designed for overhead door installation. [2] Not intended to prevent flying insects from passing through an opening. [3] (1) May be followed by revision suffix A thru Z. Prefabricated Walk-In Cooler, Freezer and Combination - Custom Size[4] [4] With refrigeration components; with or without shelving. Page 1 of 2Listing Category Search Page | NSF International 4/10/2018http://info.nsf.org/Certified/Food/Listings.asp?Company=26700&Standard=007 03/17/2019 Prefabricated Walk-In Refrigerator & Storage Freezer - Custom Built[6] [7] [8] [9] [6] With or without flooring. [7] With or without shelving. [8] Without refrigeration components. [9] Materials to be used: Interior (ceilings, walls, and floors): Aluminum, stainless steel, Galvalume®, galvanized, baked enamel coating Interior (floors): Aluminum, stainless steel Exterior (ceilings, walls, and floors): Aluminum, stainless steel, Galvalume®, galvanized, baked enamel coating COMPONENTS: Prefabricated Walk-In Cooler, Freezer and Combination - Custom Size[5] [5] Without refrigeration components; with or without shelving. Prefabricated Walk-In Refrigerator & Storage Freezer - Custom Built[6] [7] [8] [9] [6] With or without flooring. [7] With or without shelving. [8] Without refrigeration components. [9] Materials to be used: Interior (ceilings, walls, and floors): Aluminum, stainless steel, Galvalume®, galvanized, baked enamel coating Interior (floors): Aluminum, stainless steel Exterior (ceilings, walls, and floors): Aluminum, stainless steel, Galvalume®, galvanized, baked enamel coating Number of matching Manufacturers is 1 Number of matching Products is 6 Processing time was 0 seconds Page 2 of 2Listing Category Search Page | NSF International 4/10/2018http://info.nsf.org/Certified/Food/Listings.asp?Company=26700&Standard=007 03/17/2019 03/17/2019 03/17/2019 NYWR.R8160 Building Units Page Bottom Building Units See General Information for Building Units WELBILT INC R8160 2915 TENNESSEE AVE N PARSONS, TN 38363 USA Metal covered wall and ceiling panels incorporating a foamed plastic core material for wall or wall-ceiling constructions. FOR SURFACE BURNING CHARACTERISTICS SEE CLASSIFICATION MARKOF UL ON PRODUCT OR CARTON Trademark and/or Tradename: "Manitowoc Walk-Ins", "Kolpak", "Harford" Last Updated on 2017-08-15 Questions?Print this page Terms of Use Page Top © 2018 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2018 UL LLC". Page 1 of 1NYWR.R8160 -Building Units 4/10/2018http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=N... 03/17/2019 File R8160 Page T1-9 of 9 Issued: 2012-05-09 Test Record Summary: The results of this investigation, including construction review and testing, indicate that the products evaluated comply with the applicable requirements in the Standard for Surface Burning Characteristics for Building Materials, UL723, Tenth Edition (dated September 10, 2008) and, therefore, such products are judged eligible to bear UL's Mark as described below and on the Conclusion Page of this Report. Classification Marking: The Surface Burning Characteristics as shown below in the Classification Marking represent the judgment of UL based upon the results of the examination and tests presented in this Report. Building Units Control No. SURFACE BURNING CHARACTERISTICS 6 In. Max Thick Core 3-1/2 to 6 In. Thick Painted or Unpainted Aluminum Finished Panels 3-1/2 to 6 In. Thick Painted or Unpainted, Steel or Aluminum Coated Steel Finished Panels Flame Spread 20 15 10-25 Smoke Developed 250-400 Over 500 Over 500 Test Record by: Reviewed by: Karen Foxx-Smith James Smith Engineering Associate Staff Engineering Associate Fire Protection Division Fire Protection Division Any information and documentation provided to you involving UL Mark services are provided on behalf of UL or any authorized licensee of UL. 03/17/2019 CERTIFICATE OF COMPLIANCE Certificate Number 20160209-R8160 Report Reference R8160-20120509 Issue Date 2016-FEBRUARY-09 Bruce Mahrenholz, Director North American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/ Page 1 of 2 Issued to: WELBILT INC 2915 TENNESSEE AVE N PARSONS TN 38363 This is to certify that representative samples of BUILDING UNITS-Complementary Product Category - COMPOSITE PANELS ,INSULATED BUILDING PANELS See addendum page Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: Standard Method of Test for Surface Burning Characteristics of Building Materials and Assemblies, CAN/ULC-S102-10 Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service. Look for the UL Certification Mark on the product. 03/17/2019 CERTIFICATE OF COMPLIANCE Certificate Number 20160209-R8160 Report Reference R8160-20120509 Issue Date 2016-FEBRUARY-09 Bruce Mahrenholz, Director North American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/ Page 2 of 2 This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements. The product covered by this section of the Procedure is a building unit consisting of a urethane foamed plastic core with faces of painted or unpainted aluminum, galvalume, stainless or galvanized steel. The male and female joint edges are formed of core foam, high density foam (“Insul-Frame”) or wood (“Wood Frame”). Adjoining finished panels are attached together by means of cam-locking devices incorporated into each finished panel 03/17/2019 BOARD OF BUILDING AND SAFETY COMMISSIONERS ____ VAN AMBATIELOS PRESIDENT E. FELICIA BRANNON VICE PRESIDENT JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ ____ CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI MAYOR DEPARTMENT OF BUILDING AND SAFETY 201 NORTH FIGUEROA STREET LOS ANGELES, CA 90012 ____ FRANK M. BUSH GENERAL MANAGER SUPERINTENDENT OF BUILDING OSAMA YOUNAN, P.E. EXECUTIVE OFFICER ____ RR 24808 Page 1 of 2 LADBS G-5 (Rev.02/20/2014) AN EQUAL EMPLOYMENT OPPORTUNITY - AFFIRMATIVE ACTION EMPLOYER Welbilt RESEARCH REPORT: RR 24808 (Kolpak and Hardford Brands) (CSI # 13030) 2915 Tennesee Avenue N Parsons, TN 38363 Expires: January 1, 2021 Issued Date: February 1, 2019 Attn: Tony Moffett Code: 2017 LABC (731) 847-5629 GENERAL APPROVAL –Renewal - Kolpak Modular Walk-In Cooler/Freezers. DETAILS Panels for the coolers and freezer consist of aluminum or steel skins and a core of 4" thick Dow Chemical Company-Delta-Term AF 4500/Voracor CE 157 foamed-in-place polyurethane having an average in-place density of 2.1 pounds per cubic foot. The panels are held together by use of Posi-Loc fastening devices along the edges. Flame spread and smoke density ratings per ASTM E84 are 20 and 130, respectively, for the core material. The self-ignition temperature of the foam per ASTM D-1929 is 950 F. Surface burning characteristics of the finished building unit shall not exceed 75 for flame spread and 450 for smoke developed, respectively. Kolpak freestanding walk-in coolers and freezers constructed of panels described above are approved with the following requirements: 1. The coolers and freezers shall be installed in the interior of buildings. 2. Height of units shall not exceed 10 feet. 3. The aggregate floor area of the freestanding walk-in cooler and freezers shall be less than 400 square feet. 4. The panels shall be considered combustible and may be used only in areas where combustible materials are permitted by the Code. 5. Minimum thickness of the metal skins are 26 gage (0.019") for the aluminum coated galvanized steel, 0.038" for aluminum and 22 gage (0.030") for the stainless steel. 03/17/2019 Kolpak RE: Kolpak Modular Walk-In Cooler/Freezer RR 24808 Page 2 of 2 6. The panels shall be fabricated in the shop of a fabricator licensed by the Department and shall bear identification markings. 7. Separate approval shall be required for electrical installations enclosed in the panel. Also, no electrical, plumbing or mechanical can be installed after fabrication of the panels. DISCUSSION The report is in compliance with the 2017 City of Los Angeles Building Code. The approval is based on the foam plastic insulation requirements of Section 2603 and structural tests and analysis. Addressee to whom this Research Report is issued is responsible for providing copies of it, complete with any attachments indicated, to architects, engineers and builders using items approved herein in design or construction which must be approved by Department of Building and Safety Engineers and Inspectors. This general approval of an equivalent alternate to the Code is only valid where an engineer and/or inspector of this Department has determined that all conditions of this approval have been met in the project in which it is to be used. ____________________________________ DAVID CHANG, Chief Engineering Research Section 201 N. Figueroa St., Room 880 Los Angeles, CA 90012 Phone- 213-202-9812 Fax- 213-202-9943 DE RR24808/ R01/27/2019 TLB1900013 2603 03/17/2019 03/17/2019 03/17/2019 03/17/2019 Certificate of Compliance This certificate is issued for the following: Kolpak and Harford Refrigeration Panels Prepared for: Manitowoc Walk-Ins 2915 Tennessee Ave North Parsons, TN 38363 United States FM Approvals Class: 4880 Approval Identification: 0003038478 Approval Granted: 28 March 2011 To verify the availability of the Approved product, please refer to www.approvalguide.com or www.roofnav.com Said Approval is subject to satisfactory field performance, continuing Surveillance Audits, and strict conformity to the constructions as shown in the Approval Guide, an online resource of FM Approvals. Cynthia Frank AVP - Manager of Materials FM Approvals 1151 Boston-Providence Turnpike Norwood, MA 02062 03/17/2019 AUTHORIZATION TO MARK Applicant:Manufacturer: Address:Address: Country:Country: Contact:Contact: Phone:Phone: FAX:FAX: Email:Email: Standard(s): Product: Brand Name: Models: Manitowoc FSG Operations, LLC Manitowoc FSG Operations, LLC 2915 Tennessee Ave. North Parsons, TN 39363 2915 Tennessee Ave. North Parsons, TN 39363 USA USA Randy Jones Randy Jones 731-847-6361 731-847-6361 731-847-5682 731-847-5682 randy.jones@mtwfs.com randy.jones@mtwfs.com Party Authorized To Apply Mark:Same as Manufacturer Report Issuing Office:Columbus, Ohio Control Number:40807 Authorized by: for Dean Davidson, Certification Manager This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek’s Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 UL 427 Issued: 2011/11/11 Ed: 5ed Rev: 2014/02/28 Refrigerating Units; CSA C22.2#120 Issued: 2013/03/01 Ed: 4 Refrigeration Equipment Refrigeration Units PC or DC followed by 033, 039, 049, 050, 069, 075, 099 or 100, followed by S2 or T2, optionally followed by A or O. PC or DC followed by 069, 075, 099, or 100, followed by S3 or T3, optionally followed by A or O. PF followed by, 099, 094, 144, 149, 194, or 199, followed by S3 or T3, optionally followed by A or O. Kolpak, RDI, or Manitowac Refrigeration This authorizes the application of the Certification Mark(s)shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report.This authorization also applies to multiple listee model(s)identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable.The certification mark(s)may be applied only at the location of the Party Authorized To Apply Mark. Page 1 of 2 ATM for Report 102745165COL-001 ATM Issued: 27-Sep-2017 ED 16.3.15 (20-Apr-17) Mandatory 03/17/2019 AUTHORIZATION TO MARK Applicant:Manufacturer: Address:Address: Country:Country: Contact:Contact: Phone:Phone: FAX:FAX: Email:Email: Standard(s): Product: Brand Name: Models: PC or DC followed by 033, 039, 049, 050, 069, 075, 099 or 100, followed by S2 or T2, optionally followed by A or O. PC or DC followed by 069, 075, 099, or 100, followed by S3 or T3, optionally followed by A or O. PF followed by, 099, 094, 144, 149, 194, or 199, followed by S3 or T3, optionally followed by A or O. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek’s Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 UL 427 Issued: 2011/11/11 Ed: 5ed Rev: 2014/02/28 Refrigerating Units; CSA C22.2#120 Issued: 2013/03/01 Ed: 4 Refrigeration Equipment Refrigeration Units Kolpak, RDI, or Manitowac Refrigeration Control Number:5002718 Authorized by: for Dean Davidson, Certification Manager This document supersedes all previous Authorizations to Mark for the noted Report Number. randy.jones@mtwfs.com Jason.sands@manitowoc.com Party Authorized To Apply Mark:Same as Manufacturer Report Issuing Office:Columbus, Ohio Randy Jones Jason Sands 731-847-6361 901-476-6147 731-847-5682 901-476-4668 Manitowoc FSG Operations, LLC The Delfield Company 2915 Tennessee Ave. North Parsons, TN 39363 1 Delfield Drive Covington, TN 38019 USA USA This authorizes the application of the Certification Mark(s)shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report.This authorization also applies to multiple listee model(s)identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable.The certification mark(s)may be applied only at the location of the Party Authorized To Apply Mark. Page 2 of 2 ATM for Report 102745165COL-001 ATM Issued: 27-Sep-2017 ED 16.3.15 (20-Apr-17) Mandatory 03/17/2019 AUTHORIZATION TO MARK Applicant:Manufacturer: Address:Address: Country:Country: Contact:Contact: Phone:Phone: FAX:FAX: Email:Email: Standard(s): Product: Brand Name: This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek’s Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Heating And Cooling Equipment [UL 1995:2015 Ed.5] Heating And Cooling Equipment [CSA C22.2#236:2015 Ed.5] Refrigerant Condensing Units Kolpak Control Number:40807 Authorized by: for Dean Davidson, Certification Manager This document supersedes all previous Authorizations to Mark for the noted Report Number. William.Jones@welbilt.com David.Wyatt@welbilt.com William.Jones@welbilt.com David.Wyatt@welbilt.com Party Authorized To Apply Mark:Same as Manufacturer Report Issuing Office:Columbus, OH Mr. Randy Jones Mr. David Wyatt Mr. Randy Jones Mr. David Wyatt (731) 847-6361 (731) 847-6361 (731) 847-5683 (731) 847-5683 Manitowoc FSG Operations, LLC Manitowoc FSG Operations, LLC 2915 Tennessee Ave. North Parsons, TN 39363 2915 Tennessee Ave. North Parsons, TN 39363 USA USA This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Page 1 of 2 ATM for Report 103370300COL-001 ATM Issued: 7-Mar-2018 ED 16.3.15 (20-Apr-17) Mandatory 03/17/2019 AUTHORIZATION TO MARK Models: PR, PC or PCL; followed by 45, 48, 49, 50, 54, 68, 69, 70, 74, 75, 95, 98, 99, 100, 104, 124, 128, 129, 145, 148, 149, 150, 154, 195, 198, 199, 200, 204, 248, 249, 295, 298, 299, 300, 304, 344, 348, 349, 395, 398, 399, 444, 448, 449, 495, 498, 499, 500, 504, 548, 549, 595, 598, 599 or 644; followed by L or M; may be followed by Z; may be followed by W; followed by PD or OP; followed by 1, 2, 2A, 2B, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 or 14. D; followed by PR or PCL; followed by 199, 149, 95 or 70; followed by L or M; followed by 199, 149, 95 or 70; followed by L or M; followed by PD or OP; followed by 1, 2, 3 or 4. MC; followed by 00.8 to 20.0; followed by 1, 2, 3, 4, 5, 6, 7, 8 or 9; followed by H, S or Z; followed by 1, 2, 3 or 4; followed by PD or OP; followed by 1, 2, 3, 4, 5 or 6. Page 2 of 2 ATM for Report 103370300COL-001 ATM Issued: 7-Mar-2018 ED 16.3.15 (20-Apr-17) Mandatory 03/17/2019 03/17/2019 03/17/2019 03/17/2019