Loading...
HomeMy WebLinkAboutFile Documents.506 E Main St.0054.2019 (26).ACBK Property Address Pitkin Courthouse 506 E. Main Aspen, CO 81611 Element Environmental Project#: Courthouse 051819 RT Client Job Name Courthouse Retest TABLE OF CONTENTS 1.0 - Scope of Work 2.0 - Sampling Requirements 3.0 - Sampling Methodology 4.0 - Laboratory 5.0 - Suspect Materials Sampled 6.0 - Table of Results 7.0 - Description of Sampling Area 8.0 - Conclusion 9.0 - Lab Report 10.0 - Certificates Asbestos Samples Analyzed: 14 Positive Asbestos Samples: 0 ___________________________________________________ AS B E S T O S L E A D HA Z M A T RE S T O R A T I O N ww w . e l e m e n t co n s u l t s .c o m Asbestos Sampling Report Date: 05/23/2019 Date of Inspection: 05/18/2019 Client: Pitkin County Courthouse 506 E. Main St. Aspen, CO 81611 Attn: Jodi Smith Building Inspector: Joshua Johnson CDPHE #18401 189 County Rd. 135 Glenwood Springs, CO 81601 josh@elementconsults.com (970) 274-3139 09/03/2019 Project #-Courthouse 051819 RT 2 1.0- This was an inspection for suspect ACM (Asbestos Containing Material) for a remodel. Element Environmental conducted a visible inspection for visible materials that would be impacted during the remodel. This inspection was limited to the areas found in the Description of the Sampling Area 7.0. Although sampling is destructive in nature, this was a non-invasive inspection. It was of materials that were accessible. If other suspect materials become visible/apparent during demolition or construction activities, work in that area should be halted and more sampling/testing must take place, per Colorado regulations. Any suspect materials that were not tested are to be assumed to contain asbestos. 2.0- A limited bulk sampling of from all suspect materials was conducted in accordance with Colorado State Requirements. The minimum number of samples per homogenous areas are as follows: 2.1- Surfacing Materials- <1,000 sq.ft.- Minimum of 3 samples 1,000 sq.ft.- 5,000sq.ft.- Minimum of 5 samples >5,000 sq.ft. Minimum of 7 samples 2.2- Miscellaneous materials- Minimum of 2 samples 2.3- Thermal Systems Insulation (TSI)- Minimum of 3 samples 3.0- The purpose of the inspection is to identify materials that are homogenous. A homogeneous area is defined as one which shares suspect material, texture, color, location, and/or apparent time of construction. The materials are segregated into separate homogenous areas. The size is determined and then samples are taken. The materials are touched to determine friability. Friable ACM is material that can be crushed or reduced to powder by hand pressure. The samples are taken in a random numerical sequence. 4.0- Josh Johnson, a Colorado Department of Public Health & Environment certified building inspector, certification number: 18401, performed the inspection. Samples taken were sent to CEI Labs in Cary, North Carolina. The samples were analyzed by PLM (Polarized Light Microscopy) analysis. Per the CDPHE Regulation any sample that is found by a lab to be trace, or <1% asbestos, is considered to be ACM material. This material would still be a regulated material by CDPHE. The sample must have an additional “point count” performed to be considered less than 1% and not be regulated by the CDPHE. The lab’s documents with analyses and findings are found below. 09/03/2019 Project #-Courthouse 051819 RT 3 5.0- SUSPECT MATERIALS SAMPLES • 12 x 12 Tile • Texture • Plaster • Joint Compound • Drywall • Tape • Sound Board 6.0- TABLE OF RESULTS HOMOGENOUS AREA DESCRIPTION OF AREA ACM CATEGORY NUMBER OF SAMPLES APPROXIMATE SQ.FT.* ACM ASSESSMENT CATEGORIES % AND TYPE OF ASBESTOS FOUND (A) 12 x 12 Tile in Probation Office and Treasurers Room Miscellaneous 2 ~800 sq.ft. Non-Friable Non-ACM No Asbestos Detected (B) Fire Tape in Janitor Closet Miscellaneous 2 ~80 sq.ft. Friable Non-ACM No Asbestos Detected (C) Plaster on exterior of Janitor Closet Surfacing 3 ~80 sq.ft. Friable Non-ACM No Asbestos Detected (D) Orange Peel Texture in the downstairs patrol room and investigation offices Surfacing 5 ~1500 sq.ft. Friable Non-ACM No Asbestos Detected (E) Floor Sound Board in Judges Office Miscellaneous 2 ~300 sq.ft. Non-Friable Non-ACM No Asbestos Detected Key: ACM Assessment Categories: 1- Damaged or significantly damaged Thermal Systems Insulation (TSI) ACM 2- Damaged friable surfacing ACM 3- Significantly damaged friable Surfacing ACM 4- Damaged or significantly damaged friable Miscellaneous ACM 5- ACM with potential for damage 6- ACM with potential for significant damage 7- Friable ACM with low potential for damage Other- ACM not classified in the above Assessment Categories N/A- Not Applicable * Square footage is estimated and not for bidding purposes 7.0- DESCRIPTION OF SAMPLING AREA • The 12 x 12 Tile under the sheet vinyl in the Treasurers Room and in the Probation Office • The Fire Tape and Plaster in the Janitor Closet • The Orange Peel Texture in Garden Level: Patrol Room Area, Investigation Room, Glass Office Area • The Sound Board under the carpet in the Judge’s Office 09/03/2019 Project #-Courthouse 051819 RT 4 8.0- CONCLUSION No Asbestos detected in any of the samples. Please feel free to contact me with any questions at the information below. Sincerely, Josh Johnson 09/03/2019 Project #-Courthouse 051819 RT 5 9.0- LAB REPORT 09/03/2019 Project #-Courthouse 051819 RT 6 09/03/2019 Project #-Courthouse 051819 RT 7 09/03/2019 Project #-Courthouse 051819 RT 8 09/03/2019 Project #-Courthouse 051819 RT 9 09/03/2019 Project #-Courthouse 051819 RT 10 09/03/2019 Project #-Courthouse 051819 RT 11 09/03/2019 Project #-Courthouse 051819 RT 12 10.0- CERTIFICATES 09/03/2019