Loading...
HomeMy WebLinkAboutFile Documents.555 E Durant Ave.0025.2019 (23).ACBK Property Address 555 E Durant #2E Aspen, CO 81621 Element Environmental Project#: BBConstruction 010919 Client Job Name Gorsuch Locker Room TABLE OF CONTENTS 1.0 - Scope of Work 2.0 - Sampling Requirements 3.0 - Sampling Methodology 4.0 - Laboratory 5.0 - Suspect Materials Sampled 6.0 - Table of Results 7.0 - Description of Sampling Area 8.0 - Conclusion 9.0 - Lab Report 10.0 - Certificates Asbestos Samples Analyzed: 13 Positive Asbestos Samples: 0 ___________________________________________________ AS B E S T O S LE A D HA Z M A T RE S T O R A T I O N ww w . e l e m e n t co n s u l t s . co m Asbestos Sampling Report Date: 01/11/2019 Date of Inspection: 01/09/2019 Client: Baumgartner & Bateman Construction PO Box 2676 Aspen, CO 81612 Attn: Josh Baumgartner Don Bateman Building Inspector: Ellen Johnson CDPHE #23799 Joshua Johnson CDPHE #18401 189 County Rd. 135 Glenwood Springs, CO 81601 josh@elementconsults.com (970) 274-3139 4/15/2019 Project #-BBConstruction 010919 2 1.0- This was an inspection for suspect ACM (Asbestos Containing Material) for a remodel. Element Environmental conducted a visible inspection for visible materials that would be impacted during the remodel. This inspection was limited to the areas found in the Description of the Sampling Area 7.0. Although sampling is destructive in nature, this was a non-invasive inspection. It was of materials that were accessible. If other suspect materials become visible/apparent during demolition or construction activities, work in that area should be halted and more sampling/testing must take place, per Colorado regulations. Any suspect materials that were not tested are to be assumed to contain asbestos. 2.0- A limited bulk sampling of from all suspect materials was conducted in accordance with Colorado State Requirements. The minimum number of samples per homogenous areas are as follows: 2.1- Surfacing Materials- <1,000 sq.ft.- Minimum of 3 samples 1,000 sq.ft.- 5,000sq.ft.- Minimum of 5 samples >5,000 sq.ft. Minimum of 7 samples 2.2- Miscellaneous materials- Minimum of 2 samples 2.3- Thermal Systems Insulation (TSI)- Minimum of 3 samples 3.0- The purpose of the inspection is to identify materials that are homogenous. A homogeneous area is defined as one which shares suspect material, texture, color, location, and/or apparent time of construction. The materials are segregated into separate homogenous areas. The size is determined and then samples are taken. The materials are touched to determine friability. Friable ACM is material that can be crushed or reduced to powder by hand pressure. The samples are taken in a random numerical sequence. 4.0- Ellen Johnson, a Colorado Department of Public Health & Environment certified building inspector, certification number: 23799, performed the inspection. The findings were reviewed by Josh Johnson, a Colorado Department of Public Health & Environment certified building inspector, certification number: 18401. Samples taken were sent to CEI Labs in Cary, North Carolina. The samples were analyzed by PLM (Polarized Light Microscopy) analysis. Per the CDPHE Regulation any sample that is found by a lab to be trace, or <1% asbestos, is considered to be ACM material. This material would still be a regulated material by CDPHE. The sample must have an additional “point count” performed to be considered less than 1% and not be regulated by the CDPHE. The lab’s documents with analyses and findings are found below. 4/15/2019 Project #-BBConstruction 010919 3 5.0- SUSPECT MATERIALS SAMPLES • Joint Compound • Texture • Tape • Drywall • Cinder Block Grout 6.0- TABLE OF RESULTS HOMOGENOUS AREA DESCRIPTION OF AREA ACM CATEGORY NUMBER OF SAMPLES APPROXIMATE SQ.FT.* ACM ASSESSMENT CATEGORIES % AND TYPE OF ASBESTOS FOUND (A) Skip Trowel Texture on Ceilings Surfacing 3 ~900 sq.ft. N/A No Asbestos Detected (B) Medium Roll Texture in Main Room and Storage Room Surfacing 3 ~600 sq.ft. N/A No Asbestos Detected (C) Light Roll Texture in Bathroom, South Wall of Main Room and Center Column Surfacing 3 ~600 sq.ft. N/A No Asbestos Detected (D) Plain Drywall in Bathroom Ceiling Miscellaneous 2 ~80 sq.ft. N/A No Asbestos Detected (E) Cinder Block Grout inside the Center Column Miscellaneous 2 ~120 sq.ft. N/A No Asbestos Detected Key: ACM Assessment Categories: 1- Damaged or significantly damaged Thermal Systems Insulation (TSI) ACM 2- Damaged friable surfacing ACM 3- Significantly damaged friable Surfacing ACM 4- Damaged or significantly damaged friable Miscellaneous ACM 5- ACM with potential for damage 6- ACM with potential for significant damage 7- Friable ACM with low potential for damage Other- ACM not classified in the above Assessment Categories N/A- Not Applicable * Square footage is estimated and not for bidding purposes 4/15/2019 Project #-BBConstruction 010919 4 7.0- DESCRIPTION OF SAMPLING AREA • The Skip Trowel Texture on the Ceilings throughout the unit • The Medium Roll Texture in the Main Area and Storage Room • The Light Roll Texture in the Main Area and Bathroom • The Cinder Block Grout inside the Center Column 8.0- CONCLUSION No Asbestos was detected in any of the samples. Please feel free to contact us with any questions with our information below. Sincerely, Ellen Johnson 4/15/2019 Project #-BBConstruction 010919 5 9.0- LAB REPORT 4/15/2019 Project #-BBConstruction 010919 6 4/15/2019 Project #-BBConstruction 010919 7 4/15/2019 Project #-BBConstruction 010919 8 4/15/2019 Project #-BBConstruction 010919 9 4/15/2019 Project #-BBConstruction 010919 10 4/15/2019 Project #-BBConstruction 010919 11 4/15/2019 Project #-BBConstruction 010919 12 10.0- CERTIFICATES 4/15/2019