HomeMy WebLinkAboutFile Documents.555 E Durant Ave.0025.2019 (23).ACBK
Property Address
555 E Durant #2E
Aspen, CO 81621
Element Environmental Project#:
BBConstruction 010919
Client Job Name
Gorsuch Locker Room
TABLE OF CONTENTS
1.0 - Scope of Work
2.0 - Sampling Requirements
3.0 - Sampling Methodology
4.0 - Laboratory
5.0 - Suspect Materials Sampled
6.0 - Table of Results
7.0 - Description of Sampling Area
8.0 - Conclusion
9.0 - Lab Report
10.0 - Certificates
Asbestos Samples Analyzed: 13
Positive Asbestos Samples: 0
___________________________________________________
AS
B
E
S
T
O
S
LE
A
D
HA
Z
M
A
T
RE
S
T
O
R
A
T
I
O
N
ww
w
.
e
l
e
m
e
n
t
co
n
s
u
l
t
s
.
co
m
Asbestos Sampling Report
Date: 01/11/2019
Date of Inspection: 01/09/2019
Client:
Baumgartner & Bateman
Construction
PO Box 2676
Aspen, CO 81612
Attn:
Josh Baumgartner
Don Bateman
Building Inspector:
Ellen Johnson
CDPHE #23799
Joshua Johnson
CDPHE #18401
189 County Rd. 135
Glenwood Springs, CO 81601
josh@elementconsults.com
(970) 274-3139
4/15/2019
Project #-BBConstruction 010919
2
1.0- This was an inspection for suspect ACM (Asbestos Containing Material) for a remodel.
Element Environmental conducted a visible inspection for visible materials that would
be impacted during the remodel. This inspection was limited to the areas found in the
Description of the Sampling Area 7.0. Although sampling is destructive in nature, this
was a non-invasive inspection. It was of materials that were accessible. If other suspect
materials become visible/apparent during demolition or construction activities, work in
that area should be halted and more sampling/testing must take place, per Colorado
regulations. Any suspect materials that were not tested are to be assumed to contain
asbestos.
2.0- A limited bulk sampling of from all suspect materials was conducted in accordance with
Colorado State Requirements. The minimum number of samples per homogenous areas
are as follows:
2.1- Surfacing Materials- <1,000 sq.ft.-
Minimum of 3 samples
1,000 sq.ft.- 5,000sq.ft.- Minimum of 5 samples
>5,000 sq.ft. Minimum of 7 samples
2.2- Miscellaneous materials- Minimum of 2 samples
2.3- Thermal Systems Insulation (TSI)- Minimum of 3 samples
3.0- The purpose of the inspection is to identify materials that are homogenous. A
homogeneous area is defined as one which shares suspect material, texture, color,
location, and/or apparent time of construction. The materials are segregated into
separate homogenous areas. The size is determined and then samples are taken. The
materials are touched to determine friability. Friable ACM is material that can be
crushed or reduced to powder by hand pressure. The samples are taken in a random
numerical sequence.
4.0- Ellen Johnson, a Colorado Department of Public Health & Environment certified building
inspector, certification number: 23799, performed the inspection. The findings were
reviewed by Josh Johnson, a Colorado Department of Public Health & Environment
certified building inspector, certification number: 18401. Samples taken were sent to
CEI Labs in Cary, North Carolina. The samples were analyzed by PLM (Polarized Light
Microscopy) analysis. Per the CDPHE Regulation any sample that is found by a lab to be
trace, or <1% asbestos, is considered to be ACM material. This material would still be a
regulated material by CDPHE. The sample must have an additional “point count”
performed to be considered less than 1% and not be regulated by the CDPHE. The lab’s
documents with analyses and findings are found below.
4/15/2019
Project #-BBConstruction 010919
3
5.0- SUSPECT MATERIALS SAMPLES
• Joint Compound
• Texture
• Tape
• Drywall
• Cinder Block Grout
6.0- TABLE OF RESULTS
HOMOGENOUS
AREA
DESCRIPTION OF AREA ACM CATEGORY NUMBER
OF
SAMPLES
APPROXIMATE
SQ.FT.*
ACM ASSESSMENT CATEGORIES
% AND TYPE OF
ASBESTOS FOUND
(A) Skip Trowel Texture on Ceilings Surfacing
3 ~900 sq.ft. N/A No Asbestos Detected
(B) Medium Roll Texture in Main
Room and Storage Room
Surfacing
3 ~600 sq.ft. N/A No Asbestos Detected
(C) Light Roll Texture in Bathroom,
South Wall of Main Room and
Center Column
Surfacing
3 ~600 sq.ft. N/A No Asbestos Detected
(D) Plain Drywall in Bathroom Ceiling Miscellaneous
2 ~80 sq.ft. N/A No Asbestos Detected
(E) Cinder Block Grout inside the
Center Column
Miscellaneous 2 ~120 sq.ft. N/A No Asbestos Detected
Key:
ACM Assessment Categories:
1- Damaged or significantly damaged Thermal Systems Insulation
(TSI) ACM
2- Damaged friable surfacing ACM
3- Significantly damaged friable Surfacing ACM
4- Damaged or significantly damaged friable Miscellaneous ACM
5- ACM with potential for damage
6- ACM with potential for significant damage
7- Friable ACM with low potential for damage
Other- ACM not classified in the above Assessment Categories
N/A- Not Applicable
* Square footage is estimated and not for bidding purposes
4/15/2019
Project #-BBConstruction 010919
4
7.0- DESCRIPTION OF SAMPLING AREA
• The Skip Trowel Texture on the Ceilings throughout the unit
• The Medium Roll Texture in the Main Area and Storage Room
• The Light Roll Texture in the Main Area and Bathroom
• The Cinder Block Grout inside the Center Column
8.0- CONCLUSION
No Asbestos was detected in any of the samples. Please feel free to contact us with any
questions with our information below.
Sincerely,
Ellen Johnson
4/15/2019
Project #-BBConstruction 010919
5
9.0- LAB REPORT
4/15/2019
Project #-BBConstruction 010919
6
4/15/2019
Project #-BBConstruction 010919
7
4/15/2019
Project #-BBConstruction 010919
8
4/15/2019
Project #-BBConstruction 010919
9
4/15/2019
Project #-BBConstruction 010919
10
4/15/2019
Project #-BBConstruction 010919
11
4/15/2019
Project #-BBConstruction 010919
12
10.0- CERTIFICATES
4/15/2019